Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (3)
Job Name:Partners Group System Reference:FC-1,2 Date:9/5/19 U L t 1 '( al SPECIFICATIONS CITY OF I ICARD BUILDING DIVISION Capacity* Cooling 24,000 Btu/h Heating 27,000 Btu/h Power Power Source 208/230V, 1-phase,60Hz Power Consumption Cooling 0.07 kW Heating 0.07 kW Current Cooling 0.50 A Heating 0.50 A Minimum Circuit Ampacity(MCA) 0.63 A Maximum Overcurrent Protection(MOCP)Fuse 15 A GENERAL FEATURES ExternalFinish MunsellNo.1.0Y9.2/0.2 • Dual set point functionality External Dimensions • Compact,lightweight,shiny-white,flat-panel design Inches 14-3/8 H x 46-1/16 W x 11-5/8 D • Quiet operation mm 365 H x 1,170 Wx 295 D • Multiple fan-speed settings • Intake grille filter is easily removed for cleaning Net Weight • Wireless receiver on board Unit 46 lbs./21 kg Coil Type Cross Fin (Aluminum Plate Fin and Copper Tube) OPTIONS Fan o Condensate Pump SI3100-230 Type x Quantity Line Flow Fan x 1 o CN24 Relay Kit CN24RELAY-KIT-CM3 Airflow Rate (Law-High) 570-920 CFM Motor Type Direct-drive DC Motor Air Filter Polypropylene Honeycomb Refrigerant Piping Dimensions Liquid(High Pressure) 3/8"/9.52 mm(Flare) Gas(Low Pressure) 5/8"/15.88 mm(Flare) Drainpipe Dimension I D.5/8"/16 mm Sound Pressure Levels Low-High 39-49 dB(A) Cooling/Heating capacity indicated at the maximum value at operation under the following conditions: Cooling I Indoor:BO'F(27°C)DB/67°F(19°C)WB,Outdoor 95°F(35°C)DB Heating I Indoor:70°F(21°C)DB,Outdoor 47°F(8°C)DB/43°F(6°C)WB Notes: Specifications are subject to change without notice. 02019 Mitsubishi Electric Trane HVAC US,LLC Tope Iblt,61Ya. a S. Unit:in(mm) ' 1 LA.* r ,m, wrv.ae 0El ...... ..... ill 1, III ./. NI 1„---_—_.f .,.7ki. ______=-4!-=—fnL_______ \ ,e/f� brylPVOry . . r , v _t .-, J —i B [( r_,y.7 TRTA.n BYW'' -rw"."9}brp>vgr..03 231 m`gy I v i _ Teminalhkckra B.rem.aim +h _ L _._1� `'"^"'w�Ge�mvv.. Fb no* ® m_ • ( MI s'M zn ,l-I532(u4lr++sgce ® 1 I.2722(r231 ,BS,RN162t 4,iom ® B-226m M7 Ss,n215a101M61me m 5J1321,3e U-- neMME1 al // / Piping conned'an tleparlmeM w.i.wl 1....1...61) \ cjUquidppe Refrigerant pipe:3/8 O.D(¢9.52) k.omm Flared connection.3/8F ou,ry hraug ba.p4m ®Gas pipe ReMgerant pipe:5/B O.D(p15.88) ti.Bck t.0 k,wvl T hhdB Flared connection:5/8F 42.15126 m2-15g6-o3.5/32 Drain hose 5 ) ON (m75-460) ® /8016 ID a..:.n.r.celknmumi 4 fi ,b i.le 7TTT $ , G_ Mkl MINS1/32 Mn .W.5, ¶fl' lll N1l 24 MI 65 3-I/32 '+M 65 CflmSu.rwa hale m24542.51 e S .,„.„,GIBW_ 3p s _1 5 rB• rMv.amBrc a 1.1� ... ag1y1�t■ aiiWBI�Bk AaA .10175 fB��kBs■ fl �1����� Isoa¢s�l �'3.. a t�iri=1 n g h I r a t a 74 " Oil f g t'.:m. a —1 z1z0,_ MITSUBISHI ELECTRIC Z i cE ,s . E 1 I us ask 0004eel Cer51"wtl Fr4Cit31 Intertek Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US,LLC Job Name:Partners Group System Reference:HP-1 Date:9/5/19 i IG �ortim1�1 ill:,111 � k 6 NNIIININNNINNiI�(GNNNNNINII ... 111111 NN IIII.NNNNN I' mmiiingoor 'illiONNNNNN UNNNNIIN� I IIIIIN iINNN1NNNNNlII11NN 11110N IINNN NNfN NIINN( "'INNNNNNNNN9IMNf° �. fw car UNIT OPTION ❑Standard Model(TUMYP0481AK42NA) ❑Seacoast Model(TUMYP0481AK42BA) GENERAL FEATURES • Connects up to 12 indoor units • Single-phase outdoor unit with Variable Refrigerant Flow Zoning(VRF)technology • Service accessible through both a front and side panel • Up to 984 ft.of total pipe length • ENERGY STAR®certified units' • Improved efficiency ACCESSORIES ❑Joint Kit(for details see Pipe Accessories Submittal) ❑Header Kit(for details see Pipe Accessories Submittal) n Air nutlet riili(1P(OnA Pi r.r)2(PAC-SH9ASC'-E) ❑ Front Wind Baffle(One Piece)2(WB-PA3) ❑ Drain Parr(rAC-SH97UP E) ❑ Drain Socket(PAC-SG61 DS-E) ❑ Base Pan Heater(PACSJ20BH-E) ❑Air Deflector Vertical(ADV-1) 'ENERGY STAR products are third-party certified by an EPA-recognized Certification Body 2 TUMY requires two outlet guides and wind baffles for installation. Specifications are subject to change without notice. 0 2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Nominal Cooling Capacity(208/230V)1 Btu/h 48,000 Nominal Heating Capacity(208/230V) Btu/h 54,000 Cooling(Outdoor) 5°to 115°F(-15 to+46°C)DB3 a Operating Temperature Range Heating(Outdoor) -13°to+59°F(-25°to+15.0°C)WB External Dimensions(H x W x D) In./mm 52-11/16 x 41-11/32 x 13+1/1,338 x 1050 x 330+25 Net Weight Lbs./kg 267/121 External Finish Galvanized sheets(+power coating for-BS type)<MUNSELL 3Y 7.8/1.1> Electrical Power Requirements Voltage,Phase,Hertz 208/230V, 1-Phase,60Hz Minimum Circuit Ampacity(MCA) A 29 Maximum Overcurrent Protection(MOP) A 44 Recommended Fuse Size A 30 Short-circuit Current Rating(SCCR) kA 5 Liquid(High Pressure) 3/8(9.52)Flare Piping Diameter(Flare)In./mm Gas(Low Pressure) 5/8(15.88)Flare Total Capacity 50-130%of outdoor unit capacity Indoor Unit Model/Quantity P05-P54/1-12 Fan Type x Quantity Propeller fan x 2 Fan Motor Output kW 0.074+0.074(two fan motors) Airflow Rate CFM 3,885 Cooling 23%to 100% Compressor Operating Range Heating 18%to 100% Compressor Type x Quantity INVERTER-driven Scroll Hermetic x 1 Compressor Motor Output kW 3.3 Cooling dB(A) 51 Sound Pressure Level Heating dB(A) 54 Refrigerant R410A;(10 lbs+9 oz)(4.8kg) Lubricant FV50S(2.3 liters) High Pressure High pressure sensor,High pressure switch 601 psi(4.15 MPa) Protection Devices Inverter Circuit Over-heat protection,Over-current protection Compressor Discharge thermo protection,Over-current protection EER 11.3/13.1 SEER 16.5/22.6 AHRI Ratings(Ducted/Non-Ducted) COP 3.3/4.0 HSPF 11.0/12.0 Notes 'Cooling I Indoor.81°F(27°C)DB/66°F(19°C)WB;Outdoor:95°F(35°C)D8 'Heating I Indoor:68°F(20°C)DB.0utd0or45°F(7°C)DB/43°F(6°C)W3 'When using Wnd Baffles[WB-PA3],the minimum operating range is 5°F.Without Wind Baffles,the minimum operating range is 23°F. When connecting TPKFYP006BM142B/TPKFYP008HM142A,TPFFYP(006/008/012)CS140A or TPFFYP(006/008/012)RE140A indoor units, the minimum operating range is 50°F. Specifications are subject to change without notice. C 2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. rn -13 ra n 0 1 FREE SPACE(Around the unit) 2 SERVICE SPACE 3 FOUNDATION BOLTS 4 PPNG-WFING DIRECTIONS I� I m 1M ddooaarran hone slaws a bode maple. Dimsmcns of spose needed Reese sire IFe mil Frtiy Pp tool wiwtg reorod a w �' y Rear Air Intake NU NNW^°" Eaploratbn of particles details ae for service access are %eh 4 Notion BIA<W3/8.I bills. ton be node M1m 4 dreclimx 0.m ��// eo^ any n""°�^y^o`0:44 m OM h the nslolkfion ands etc shown b the below dogom IB s and washes mil be Front,Right.Rear and Below. c Q grdlwed locally.) J n <Fgundohon bolt height. Side Air Intake Et IMP',..L.2 [ > ti _ ____,_.. i . en e ph on `--._ .x .. % m !- n i ..zuN. �IL Q-L411 t o —'—'—'—' '— Air Discharge n . n C beenUr WO SIN It MY NNINJOLINNI )fS.I VY roteridole wilt NNE '� 1 Illd M,111PiIU.�l�1�\1��II i 4oi0heesoami! %��� e •j lIIlI`: Example of Notes N bdeK $ AA1 111 �1101I iiEll • O•''pdwpaae 64%pee convoke FLAN]r 6ea WE w'1n0 mey S fliti 0••Ney�t too pve mrernn IRMA p5ilLlFl , O (I B 'll ll�"I�,. Iu���1 II\.a�lIi ..,If I _al•••wco of SSW VALVE mnemIaalmrI�Illr I�p. I!�I,'�tlla Kdde L . ahem.1 II �I�V�I•;'i'I ©0 'Q Piping Knack-Out Hole Details a I ' I II Ili ■ f '��, W<d! r:ev` so...... Maas M.N. ..fa... Mn M�ohtsLL .s Fat mew weer kw Lott MY Mn nMa Mr Until Me eerie b as wr day pvhvmnodan 006* .NmYmkall I rR toed vn ptl. __.. II]_y Mar FaaaVWMe ONITJWrsk{VA GAN h4 N.... ... 1 ��� '--��'O madval /N07..1- 00 e31 wno-t, na ''rite rev. �i�/' + Z' �• !,� � I'wow p mrm wp�p mr N° "mVk-an.,, �a Fa..R li.; f 8i���■ �i wmm Pg .M �� ivltarmart ri. � °A1I�mmbd E2:7 „Amon pg pev+.1{ ,ga M'm" NV m44"ahlr ! ,ga 1F rsaa. a amtww ® i rmr spp[Yyp nee/-' i 4 T/.wm_ pvkAAl a t f ., dSo-a^' —__ Yd..VL_ �� to A Mtt-0AI nee. a A a» - e R C o m N 3 N S Yrl N g N D m re mN �c AO / a73 CO —i1 ON • m. I ry� 6 PAR-33MAA-J I �u LT� MA REMOTE: CONTROLLER ELECTRIC Job Name: Partners Group ;System Reference FC-1,2 1 Date 9/5/19 14 39 Fr u Je tsifo n:,,:,:2xscn "s- • Cool t Set temp. Auto *e LOB. J a tt28.5-c x� ` l5 I JI 1 II 1 0 Full Vew Basic View CAPABILITIES • Basic Operations • Outdoor Unit silent mode - On/Off -Schedulable:Mon,Tue,Wed,Thu,Fri,Sat,Sun - Operation Mode:Cool,Dry,Fan,Heat,Auto(Dual or Single set -Start/Stop times in 5-minute increments point) -Silent Levels: Normal,Middle,Quiet - Set Temperature • Energy saving features: - Fan Speed -Automatic return to preset temperature setpoint if set point is - Daylight Savings Time(DST) changed from the remote controller after a preset time range • Vane setting:Auto,Step 1-5,Swing • Cool preset temp:Cool,Dry,Auto-Cool • Louver:Off,Swing On • Heat preset temp:Heat,Auto-Heat • Vent.(Lossnay):Off,Low,High • Range of 30 to 120 minutes in 10-minute increments - Manual vane angle:No Setting,Step 1-5,Draft reduction,All outlet - Energy-saving Operation Schedule • • Draft reduction mode keeps the vane angle more horizontal than • Operation schedule the angle of Step 1 • Four daily patterns with time periods in 5-minute increments and • Restriction energy-saving rate 0%to 90% -Set Temperature range limit • 7 day programming -Operation lock:On/Off,Mode,Set Temp,Vane • Night setback • High power -Starts Heat/Cool operation when room temperature exceeds - Operate at higher-than-normal capacity to bring room to set preset temperature range temperature quickly for up to 30 minutes -Adjustable time range in 5-minute increments • No Occupancy Auto-OFF • Main display - 3D i-See sensor required - Full:Shows all icons and values • On/Off timer - Basic:Limited to Mode,Set Temp.,Fan,Tme&Day -Set On Tme in 5-minute increments • Backlight Display -Set Off Time in 5-minute increments • Adjustable Contrast Level - Repeat daily - Language:English,French,Spanish,Italian,Portuguese,Greek, - Home screen display icon Turkish,Swedish • Auto-Off timer • CITYMULTI5 Function setting -Automatically turns unit off after preset time • Filter maintenance notification -Time range of 30 to 240 minutes in 10-minute increments • Error code notification - Home screen display icon • Weekly timer -Set each day Monday through Sunday - 1 to 4 time periods per day in 5-minute increments -Set Mode:On/Off/Auto(Dual set point) -On/Off/Auto -Set Temperature "(All Capabilities are dependent on the model connected) Specifications are subject to change without notice. Copyright CO 2017 Mitsubishi Electric US,Inc. SPECIFICATIONS DIMENSIONS Product size In.(mm) 4 3/4 x 4 3/4 x 3/4 120[4-3/4] 9[3/4 (WXHXD) !(120x120x19) Net we ..........._.._..._.. --- eight weight --.- , Lbs.(kg) 9/16(0.25) '.Rated power supply voltage !12 VDC (supplied from indoor units) Power W 0.3 consumption v Usage environment Temperature:0 to 40°C N 04°F) 0 0 0 O Humidity:30 to 90%RH (with no condensation) Panel PMMA (Front view) (Side view) Material Main body PC+ABS • Sound Pressure dB(A) <70[A-weighted sound Level ;pressure level]'1 *1 Per Machinery Directive 2006/42/EC Notes: MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA30024 Toll Fra ee::800-433-4822 www.mehvac,com FORM#PAR-33MAA-J MA Remote Controller for CITVMULTI5- cus 201706 Intertek Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc.