Report DN-60611:A
Wheelock® ExcederTM N OT I F I E R®
Horns and Strobes
by Honeywell
Audio/Visual Devices
General
The Wheelock® ExcederTM Series of notification appliances ,;,,
feature a sleek modern design and numerous features includ- ;}PAIN
ing eight candela options in one appliance, low current draw,
no tools needed for setting changes, 12/24 VDC operation,
universal mounting base and multiple mounting options.
r
, ,'.
Models with an audible feature 3 sound settings (90, 95," +a s } , , Wall
dB).All switches to change settings can be set without the u"se
of a tool and are located behind the appliance to prevent tam-
pering. Wall models feature voltage test points to take read-
ings with a voltage meter for troubleshooting and AHJ F''R e
inspection. Ceiling
The Wheelock®Exceder Series of wall and ceiling notifica- r:
tion appliances feature a Universal Mounting Base (UMB) i f i t%
designed to simplify the installation and testing of horns,
strobes,and combination horn strobes.The separate universal
mounting base can be pre-wired to allow full testing of circuit ,.,
wiring before the appliance is installed and the surface is fin-
ished. It comes complete with a contact cover for protection
against dirt,dust,paint and damage to the contacts.The con-
tact cover also acts as a shunting device to allow pre-wire test- General Notes
ing for common wiring issues.
The contact cover is polarized to prevent it from being installed •
All candela ratings represent minimum effective strobe
incorrectly and prevents the appliance from being installed intensity based on UL Standard 1971.
while it is on the UMB.When the contact cover is removed the • Series Exceder Strobe products are Listed under UL Stan-
circuit will show an open until the appliance is installed. The dards 1971 and 464 for indoor use with a temperature
UMB allows for consistent installation and easy replacement of range of 32°F to 120°F(0°C to 49°C)and maximum humid-
appliances if required.Wall models provide an optional locking ity of 93%(±2%)UL 464(85%UL 1971).
screw for extra secure installation, while the ceiling models • Series Exceder horns are under UL Standard 464 for audi-
provide a captive screw to prevent the screw from falling during ble signal appliances(Indoor use only).
installation. • Product naming conventions: The Exceder line's model
Features codes break down into easy-to-remember codes.
HN = Horn, ST = Strobe, HS = Horn-strobe, C = Ceiling
• Multiple voltages Mount,W=White,and R=Red.So"STRC"can be read as
• Voltage test points for quick troubleshooting and easy spot- "Strobe, Red, Ceiling-mount."., and"HSW"is"Horn-strobe,
checking(wall models only) white,wall-mount"
• 3 audible settings(90,95,99 dB) • Refer to your fire alarm panel or power supply manual when
8 Candela settings calculating the number of devices allowed per circuit.
• —Wall-15/1575/30/75/95/110/135/185 Architects/Engineers Specifications
—Ceiling-15,30,60,75,95, 115, 150,177 The notification appliances shall be Wheelock Exceder Series
• Finger-slide switches HS Audible Strobe appliances,Series ST Visual Strobe appli-
• Sleek modern aesthetics ances and Series HN Audible appliances or approved equals.
• Common base for wall and ceiling with 5 mounting options: The Series HS and ST Strobes shall be listed for UL Standard
1971 (Emergency Devices for the Hearing-Impaired)for Indoor
—1-gang Fire Protection Service.The Series HS and HN Audibles shall
—2-gang be UL Listed under Standard 464 (Fire Protective Signaling).
—4 inch square All Series shall meet the requirements of FCC Part 15 Class B.
—3.5 inch octagonal All inputs shall be compatible with standard reverse polarity
supervision of circuit wiring by a Fire Alarm Control Panel
—4 inch octagonal (FACP) with the ability to operate from 8 to 33 VDC. Indoor
Com atibilit and Requirements wall models shall incorporate voltage test points for easy volt-
Compatibility 4 age inspection.
• Synchronize using Wheelock Sync Modules,or panels with The Series HS Audible Strobe and ST Strobe appliances shall
built-in Wheelock patented sync protocol. produce a flash rate of one flash per second over the Regu-
• Compatible with UL"Regulated Voltage"using filtered VDC lated Voltage Range and shall incorporate a Xenon flashtube
or unfiltered VRMS input voltage enclosed in a rugged Lexan®lens.The Series shall be of low
• Strobes produce one flash per second over the Regulated current design.Where Multi-Candela appliances are specified,
Voltage range. the strobe intensity shall have 8 field selectable settings at 15,
DN-60611:A•05/03/2010—Page 1 of 2
15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and shall been round and have a low profile with a diameter of
15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of
The selector switch for selecting the candela shall be tamper 6.68"x 1.50"D.
resistant.The 15/75 candela strobe shall be specified when 15
candela UL Standard 1971 Listing with 75 candela on-axis is SYNCHRONIZATION
required(e.g. ADA compliance).Appliances with candela set- When synchronization is required,the appliance shall be com-
tings shall show the candela selection in a visible location at all patible with Wheelock®(s SM, DSM Sync Modules, Whee-
times when installed. lock® Power Supplies or other manufacturerfs panels with
The audible shall have a minimum of three field selectable set- built-in Wheelock®Patented Sync Protocol.The strobes shall
tings for dBA levels and shall have a choice of continuous or not drift out of synchronization at any time during operation. If
temporal(Code 3)audible outputs. the sync protocol fails to operate, the strobe shall revert to a
non-synchronized flash-rate and still maintain one flash per
MOUNTING OPTIONS second over its Regulated Voltage Range.The appliance shall
The Series HS Audible Strobe,ST Strobe and Series HN Audi- also be designed so that the audible signal may be silenced
ble shall incorporate a patented Universal Mounting Base that while maintaining strobe activation when used with Whee-
shall allow mounting to a single-gang,double-gang,4"square, lock®synchronization protocol.
3.5" octagonal, 4" octagonal or 100mm European type back Standards and Codes
boxes. Two wire appliance wiring shall be capable of directly
connecting to the mounting base. Continuity checking of the Modules in this series comply with UL Standard 1971, UL
entire NAC circuit prior to attaching any notification appliances Standard 464,California State Fire Marshal(CSFM),and ULC.
shall be allowed.Product shall come with contact cover to pro-
tect contact springs. Removal of an appliance shall result in a Agency Listings
supervision fault condition by the Fire Alarm Control Panel These listings and approvals apply to the modules specified in
(FACP).The mounting base shall be the same base among all this document.In some cases,certain modules or applications
horn,strobe,horn strobe,wall and ceiling models.All notifica- may not be listed by certain approval agencies,or listing may
tion appliances shall be backwards compatible. be in process.Consult factory for latest listing status.
PHYSICAL SPECIFICATIONS • UL Listed:S5391 (Strobes);E5946(Horns,Horn/strobes).
The Series HS and ST wall models shall have a low profile • ULC Listed
measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall . CSFM Listed:7125-0785:168.
measure 5.24"H x 4.58"W x 1.6'D.The Series HSC and STC
Specification & Ordering Information
Model Strobe Candela 12/24 VDC Mounting Options
Horn Strobes
HSR 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
HSW 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
HSRC 15,30,60,75,95,115,150,177 X Universal Mounting Base
HSWC 15,30,60,75,95,115,150,177 X Universal Mounting Base
Strobes
STR 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
STW 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
STRC 15,30,60,75,95,115,150,177 X Universal Mounting Base
STWC 15,30,60,75,95,115,150,177 X Universal Mounting Base
Horns
HNR - X Universal Mounting Base
HNW - X Universal Mounting Base
HNRC - X Universal Mounting Base
HNWC - X Universal Mounting Base
*12 VDC models feature 15 and 15/75 settings
NOTE:Due to continuous development of Cooper Wheelock products,specifications and offerings are sub-
ject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard
terms and conditions.
Notifier®is a registered trademark of Honeywell International Inc.
Exceder is a trademark and Wheebck®is a registered trademark of Cooper
Notification.
02010 by Honeywell International Inc.All rights reserved.Unauthorized use
of this document is strictly prohibited.
This document is not intended to be used for installation purposes. .....
We try to keep our product information up-to-date and accurate. :;:::�
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
Made in the U.S.A.
For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118.
www.notifier.com
Page 2 of 2-DN-60611:A•05/03/2010
DN-60611:A
Wheelock® ExcederTM NOT 1 F 1 E R®
Horns and Strobes
by Honeywell
Audio/Visual Devices
General 4
The Wheelock® ExcederTM Series of notification appliances 1
feature a sleek modern design and numerous features includ- <
ing eight candela options in one appliance, low current draw, iV=ti 1_ 1
no tools needed for setting changes, 12/24 VDC operation,
universal mounting base and multiple mounting options.
Models with an audible feature 3 sound settings (90, 95, 99 , Wall /
dB).All switches to change settings can be set without the intl.',
k
of a tool and are located behind the appliance to prevent tam-
pering. Wall models feature voltage test points to take read •
-
ings with a voltage meter for troubleshooting and AHJ F
inspection. d Ceiling
The Wheelock®Exceder Series of wall and ceiling notifica- 4a
tion appliances feature a Universal Mounting Base (UMB) lt‘
designed to simplify the installation and testing of horns,
strobes,and combination horn strobes.The separate universal
mounting base can be pre-wired to allow full testing of circuit
wiring before the appliance is installed and the surface is fin-
ished. It comes complete with a contact cover for protection
against dirt,dust,paint and damage to the contacts.The con-
tact cover also acts as a shunting device to allow pre-wire test- General Notes
ing for common wiring issues.
The contact cover is polarized to prevent it from being installed •
All candela ratings represent minimum effective strobe
incorrectly and prevents the appliance from being installed intensity based on UL Standard 1971.
while it is on the UMB.When the contact cover is removed the • Series Exceder Strobe products are Listed under UL Stan-
circuit will show an open until the appliance is installed. The dards 1971 and 464 for indoor use with a temperature
UMB allows for consistent installation and easy replacement of range of 32°F to 120°F(0°C to 49°C)and maximum humid-
appliances if required.Wall models provide an optional locking ity of 93%(±2%)UL 464(85%UL 1971).
screw for extra secure installation, while the ceiling models • Series Exceder horns are under UL Standard 464 for audi-
provide a captive screw to prevent the screw from falling during ble signal appliances(Indoor use only).
installation. • Product naming conventions: The Exceder line's model
Features codes break down into easy-to-remember codes.
HN = Horn, ST = Strobe, HS = Horn-strobe, C = Ceiling
• Multiple voltages Mount,W=White,and R=Red.So"STRC"can be read as
• Voltage test points for quick troubleshooting and easy spot- "Strobe, Red,Ceiling-mount."., and"HSW"is"Horn-strobe,
checking(wall models only) white,wall-mount.
• 3 audible settings(90,95,99 dB) • Refer to your fire alarm panel or power supply manual when
• 8 Candela settings calculating the number of devices allowed per circuit.
—Wall-15/1575/30/75/95/110/135/185 Architects/Engineers Specifications
—Ceiling-15,30,60,75,95, 115,150, 177 The notification appliances shall be Wheelock Exceder Series
• Finger-slide switches HS Audible Strobe appliances,Series ST Visual Strobe appli-
• Sleek modern aesthetics ances and Series HN Audible appliances or approved equals.
• Common base for wall and ceiling with 5 mounting options: The Series HS and ST Strobes shall be listed for UL Standard
1971 (Emergency Devices for the Hearing-Impaired)for Indoor
—1-gang Fire Protection Service.The Series HS and HN Audibles shall
—2-gang be UL Listed under Standard 464 (Fire Protective Signaling).
—4 inch square All Series shall meet the requirements of FCC Part 15 Class B.
—3.5 inch octagonal All inputs shall be compatible with standard reverse polarity
supervision of circuit wiring by a Fire Alarm Control Panel
—4 inch octagonal (FACP) with the ability to operate from 8 to 33 VDC. Indoor
Compatibility and Requirements wall models shall incorporate voltage test points for easy volt-
age inspection.
• Synchronize using Wheelock Sync Modules,or panels with The Series HS Audible Strobe and ST Strobe appliances shall
built-in Wheelock patented sync protocol. produce a flash rate of one flash per second over the Regu-
• Compatible with UL"Regulated Voltage"using filtered VDC lated Voltage Range and shall incorporate a Xenon flashtube
or unfiltered VRMS input voltage enclosed in a rugged Lexan®lens.The Series shall be of low
• Strobes produce one flash per second over the Regulated current design.Where Multi-Candela appliances are specified,
Voltage range. the strobe intensity shall have 8 field selectable settings at 15,
DN-60611:A•05/03/2010—Page 1 of 2
15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and shall been round and have a low profile with a diameter of
15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. 6.68" x 2.63' D. Series HNC ceiling shall have a diameter of
The selector switch for selecting the candela shall be tamper 6.68"x 1.50"D.
resistant.The 15/75 candela strobe shall be specified when 15
candela UL Standard 1971 Listing with 75 candela on-axis is SYNCHRONIZATION
required(e.g.ADA compliance).Appliances with candela set- When synchronization is required,the appliance shall be corn-
tings shall show the candela selection in a visible location at all patible with Wheelock®is SM, DSM Sync Modules, Whee-
times when installed. lock® Power Supplies or other manufacturerfs panels with
The audible shall have a minimum of three field selectable set- built-in Wheelock®Patented Sync Protocol.The strobes shall
tings for dBA levels and shall have a choice of continuous or not drift out of synchronization at any time during operation.If
temporal(Code 3)audible outputs. the sync protocol fails to operate, the strobe shall revert to a
non-synchronized flash-rate and still maintain one flash per
MOUNTING OPTIONS second over its Regulated Voltage Range.The appliance shall
The Series HS Audible Strobe,ST Strobe and Series HN Audi- also be designed so that the audible signal may be silenced
ble shall incorporate a patented Universal Mounting Base that while maintaining strobe activation when used with Whee
shall allow mounting to a single-gang,double-gang,4"square, lock®synchronization protocol.
3.5' octagonal, 4" octagonal or 100mm European type back Standards and Codes
boxes. Two wire appliance wiring shall be capable of directly
connecting to the mounting base. Continuity checking of the Modules in this series comply with UL Standard 1971, UL
entire NAC circuit prior to attaching any notification appliances Standard 464,California State Fire Marshal(CSFM),and ULC.
shall be allowed.Product shall come with contact cover to pro-
tect contact springs. Removal of an appliance shall result in a Agency Listings
supervision fault condition by the Fire Alarm Control Panel These listings and approvals apply to the modules specified in
(FACP).The mounting base shall be the same base among all this document.In some cases,certain modules or applications
horn,strobe,horn strobe,wall and ceiling models.All notifica- may not be listed by certain approval agencies,or listing may
tion appliances shall be backwards compatible. be in process.Consult factory for latest listing status.
PHYSICAL SPECIFICATIONS • UL Listed:S5391 (Strobes);E5946(Horns,Horn/strobes).
The Series HS and ST wall models shall have a low profile • ULC Listed
measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall . CSFM Listed:7125-0785:168.
measure 5.24"H x 4.58'W x 1.6"D.The Series HSC and STC
Specification & Ordering Information
Model Strobe Candela 12124 VDC Mounting Options
Horn Strobes
HSR 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
HSW 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
HSRC 15,30,60,75,95,115,150,177 X Universal Mounting Base
HSWC 15,30,60,75,95,115,150,177 X Universal Mounting Base
Strobes
STR 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
STW 15,15/75,30,75,95,110,135,185 X Universal Mounting Base
STRC 15,30,60,75,95,115,150,177 X Universal Mounting Base
STWC 15,30,60,75,95,115,150,177 X Universal Mounting Base
Horns
HNR - X Universal Mounting Base
HNW - X Universal Mounting Base
HNRC - X Universal Mounting Base
HNWC - X Universal Mounting Base
*12 VDC models feature 15 and 15/75 settings
NOTE:Due to continuous development of Cooper Wheelock products,specifications and offerings are sub-
ject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard
terms and conditions.
Notifier®is a registered trademark of Honeywell International Inc.
Exceder is a trademark and Wheelock®is a registered trademark of Cooper
Notification.
®2010 by Honeywell International Inc.All rights reserved.Unauthorized use
of this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
Made in the U.S.A.
For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118.
www.notifier.com
Page 2 of 2-DN-60611:A•05/03/2010