Loading...
Plans (598) JOB NAME: Tigard Triangle Building #3 /Site Work CITY OF TIGARD JOB ADDRESS: 11850 SW 67th, Tigard, OR BUILDING DEPARTMENT DATE: August 8, 2006 13125 HALL BOULEVARD MCE Project No.: 060891 TIGARD, OR 97223 SHEET 1 OF 1 Tigard Building Permit SIT2006 -00006 STRUCTURAL PLAN REVIEW #1 Plans Dated 5/10/06; Calculations Dated 6/26/06 Corr. Item Page No. Comments . Code Section Made No. 1 Sheet S7.1 Masonry Submit calculations and.details with masonry 106.1.1 Calculations Pgs. 2, 14, etc. stress per element. Clarify conflict on masonry stresses. 2 Sheet S9.1 Submit when or how often for type of work 1074 Special Inspection Program listed as periodic. 3 Sheet S7.3 calculations Submit soils report for values used for 106.1.1 seismic loading. 4 Calculations sheet 5 Submit calculations with safety factor on all 1806 walls. 5 Special Inspection Special inspection is required for concrete, 1704 reinforcing steel, embed plates, bolts and masonry. 6 Structural Observation Structural observation is required for all 1709 concrete or masonry retaining and screen walls. 7 General (shop drawing) Submit one set of reinforcing steel shop drawings, which have been reviewed and initialed by the Project Engineer, to be filed with the -city of Tigard before placement. 8 General Approved resolution of the above items shall be incorporated into submittal plans before a permit will be issued. Submit four (4) sets of revised plans to the city of Tigard. � c V �v JL �C Ae4A 4 ,V ) \ AI