Plans (575) JOB NAME: Tigard Triangle Building CITY OF TIGARD
`JOB ADDRESS: 11850 SW 67th, Tigard, OR �I� ' CO BUILDING DEPARTMENT
DATE: June 1, 2006 13125 HALL BOULEVARD
MCE Project No.: 060593 TIGARD, OR 97223
SHEET 1 OF 4 Tigard Building Permit BUP2006 -00206 •
STRUCTURAL PLAN REVIEW #1
Plans Dated 5/10106
Corr. Item Page No. Comments Code Section •
Made No.
1 Sht. A1.3 Submit calculation including seismic for trash 106.1.1
Detail 9/A1.3 enclosure walls.
2 Sht. A1.2.2 Submit calculations and details for canopy 106.1.1
Detail 1/A1.2.2 including wind.
3 Sht. A4.2 Submit calculations and details for glazed 106.1.1
Detail 1 /A4.2 storefront system.
4 Sht. A4.3 Submit calculations and details for glazed 106.1.1 •
Detail 1 /A4.3 storefront system.
5 Sht. S1.0 Seismic criteria, site class 'C' to be verified 106.1.1
by soils report.
6 Sht. S1.0 Submit when or how often for type of work 1704 •
Special Inspection listed as periodic.
Program
7 Sht. S1.0 Special Submit method of tightening for high strength 1704
Inspection Program bolting.
8 Sht. S2.1.1 Submit calculations for foundation retaining 106.1.1
Detail 1/S2.1.1 walls.
9 Sht. S2.1.2 Submit calculations for foundation retaining 106.1.1
Detail 1/S2.1.2 walls.
10 Sht. S2.2.1 Submit calculations and details for length of 106.1.1
Detail 1/S2.2.1 W16x31 @ grids 3.0 between B.5 and C,
W16x26 @ grids 2.7 between A and A.5,
etc.
11 Sht. S2.2.1 Submit calculations and details for 106.1.1
Detail 1/S2.2.1 connections of 40 VG6N, rolled HSS
10x4x1/4 and connections and HSS
5x5x3/16 connections.
12 Sht. S2.2.1 Submit calculations and details for framing 106.1.1
Detail 1/S2.2.1 grids 2 to -2 from D to E. •
13 Sht. S2.2.1 Submit calculations for expansion and 106.1.1
Detail 1/S2.2.1 shrinkage on grid -2.0 for full length member.
•
JOB NAME: Tigard Triangle Building CITY OF TIGARD
JOB ADDRESS: 11850 SW 67th, Tigard, OR BUILDING DEPARTMENT
DATE: June 1, 2006 13125 HALL BOULEVARD
MCE Project No.: 060593 TIGARD, OR 97223
SHEET 2 OF 4 Tigard Building Permit BUP2006 -00206 •
STRUCTURAL PLAN REVIEW #1
Plans Dated 5/10/06
Corr. Item Page No. Comments Code Section
Made No.
14 Sht. S2.2.2 Clarify detail 14/S5.1 @ grids -3.3 and B.5 106.1.1
Detail 1/S2.2.2 and Detail 14/S5.3 @ grids -31 and C.
15 Sht. S2.2.2 Submit calculations and detail for connection 106.1.1
Detail 1/S2.2.2 @ grids -3.0 and C.7.
16 Sht. 2.3.1 Clarify detail 9/S5.4 @ grids 3.2 and C and 106.1.1
Detail 1/S2.3.1 detail 14/S5.1 @ grids -2.0 and E.
17 Sht 2.3.1 and Clarify snow Toad at mechanical screen. 106.1.1
Sht. 2.3.2
18 Sht. S3.2 Submit calculations for bent plate 1/8. 106.1.1
Detail 17/S3.2
19 Sht. S3.2 Submit sheet S5.5. 106.1.1
Details 16 and 17/S3.2
20 Sht. S4.1 Clarify difference between reinforcing steel 106.1.1
Detail 9/S4.1 per calculations page CF 53 and noted on
detail.
21 Sht. S4.1 Clarify 4 inches of weld on 3'/2 inch plate. 106.1.1
Detail 13/S4.1
22 Sht. S4.1 Submit calculations for edge distance of 106.1.1
•
Detail 15/S4.1 embedded anchors and reinforcing on
bottom plate.
23 Sht. S5.1 Clarify use of 6 inch wide face plate at 8" 106.1.1
Detail 3/S5.1 HSS or larger.
24 Sht. S5.1 Submit calculations and details for torsion 106.1.1
Detail 6/S5.1 effects on concrete panel.
25 Sht. S5.2 Submit calculations and details for torsion 106.1.1
Detail 2/S5.2 effects on concrete panel.
26 Sht. S5.2 Clarify use of 5 inch face plate at HSS 8x8. 106.1.1
Detail 5/S5.2
•
27 Sht. S5.2 Clarify 3/8x4x1' -0" plate and typical weld at 106.1.1
Detail 16/S5.2 each end.
JOB NAME: Tigard Triangle Building CITY OF TIGARD
'JOB ADDRESS: 11850 SW 67th, Tigard, OR BUILDING DEPARTMENT
DATE: June 1, 2006 13125 HALL BOULEVARD
MCE Project No.: 060593 TIGARD, OR 97223
SHEET 3 OF 4 Tigard Building Permit BUP2006 -00206
STRUCTURAL PLAN REVIEW #1
Plans Dated 5/10/06
Corr. Item Page No. Comments Code Section
Made No.
28 Sht. S5.3 Submit calculations and details for weld on 106.1.1
Details 1/S5.3 and knife plate to embedded plate.
3/S5.3
29 Sht. S5.3 Submit calculations and details for bearing 106.1.1
Detail 2/S5:3 plate and vertical plates with welds.
30 Sht. S5.3 Submit calculations for headed stud anchor 106.1.1
Detail 4/S5.3 combination
31 Sht. S5.3 Submit calculations for headed 106.1.1
Detail 5/S5.3 stud /reinforcing steel anchors.
32 Sht. S5.3 Submit calculations and details for 106.1.1
Detail 12/S5.3 mechanical screen including height.
33 Sht. S5.3 Submit calculations and details for weld on 106.1.1
Detail 18/S5.3 knife plate to embedded plate.
34 Sht. S5.3 Submit calculations and details for 106.1.1
•
Detail 19/S5.3 embedded plate.
35 Sht. S5.3 Clarify weld at W12x26. 106.1.1
Detail 20/S5.3
36 Calculations Submit calculations for 10 PSF snow load 106.1.1
RFI with mechanical screen.
37 Calculations L1, L4, Submit calculations for lateral with brick Toad 106.1.1
P56, P57, P64 and and load distribution which agree with
P71 applied loads.
•
38 Special Inspection Special inspection is required for concrete, 1704
welding, reinforcing steel, bolting, welded 1705
studs, embed plates, bolts in concrete, 1707
masonry, soils, structural steel fabrication 1708
and erection, adhesive and expansion
anchor installation.
39 Structural Observation Structural observation is required for 1709
concrete foundation, retaining walls,
reinforcing steel in tilt -up panels, before
concrete placement at second floor,
placement of floor joist and girders and roof
deck welding.
.- JOB NAME: Tigard Triangle Building CITY OF TIGARD
'JOB ADDRESS: 11850 SW 67th, Tigard, OR BUILDING DEPARTMENT
DATE: June 1, 2006 13125 HALL BOULEVARD
MCE Project No.: 060593 TIGARD, OR 97223
SHEET 4 OF 4 Tigard Building Permit BUP2006 -00206
STRUCTURAL PLAN REVIEW #1
Plans Dated 5/10/06
Corr. Item Page No. Comments Code Section
Made No.
40 General Submit one set of reinforcing steel shop
drawings, which have been reviewed and
initialed by the project engineer, to be filed
with the City of Tigard before placement.
41 General Submit one set of steel open -web joist and
girders shop drawings, which have been
reviewed and initialed by the project
engineer, to be filed with the City of Tigard
before placement.
42 General Submit one set of light gage metal
framing shop drawings, which have
been reviewed and initialed by the
project engineer, to be filed with the City
of Tigard before placement.
43 General Submit one set of steel decking shop
drawings, which have been reviewed and
initialed by the project engineer, to be filed
with the City of Tigard before placement.
44 General Submit one set of stair framing shop
drawings, which have been reviewed and
initialed by the project engineer, to be filed
with the City of Tigard before placement.
45 General Submit one set of miscellaneous steel shop
•
drawings, which have been reviewed and
initialed by the project engineer, to be filed
with the City of Tigard before placement.
46 General Submit one set of electrical and mechanical
component anchorage, which have been
reviewed and initialed by the project
engineer, to be filed with the City of Tigard
before placement.
47 General Approved resolution of the above items shall
be incorporated into submittal plans before a
permit will be issued. Submit four (4) sets of
revised plans to the city of Tigard.