Plans (53) rte
JOB NAME: Tigard Triangle Building #3 /Site Work; CITY OF TIGARD
JOB ADDRESS: 11850 SW 67th, Tigard, OR < . - "`' ' C,
DATE: August 25, 2006 M �� BUILDING DEPARTMENT
MCE Project No 060891 < <r `� 13125 HALL BOULEVARD
x - . /; TIGARD, OR 97223
SHEET 1 OF 1
,, , �' Tigard Building Permit SIT2006 -00006
STRUCTURAL' PLaN REVIEW #2
Plans Dated 5/10/06; Cal Dated 8/17/06
Corr. Item Page No. Comments Code Section
_ Made No.
8/21/06 1 Sheet S7.1 Masonry Submit calculations and details with masonry 106.1.1
Calculations Pgs. 2, 14, etc. stress per element. Clarify conflict on
masonry stresses.
8/21/06 2 Sheet S9.1 Submit when or how often for type of work 1074
Special lnspection Program listed as periodic.
8/21/06 3 Sheet S7.3 calculations Submit soils report for values used for 106.1.1
seismic loading.
8/21/06 4 Calculations sheet 5 Submit calculations with safety factor on all 1806
walls.
5 Special Inspection Special inspection is required for concrete, 1704
reinforcing steel, embed plates, bolts and
masonry.
-
• 6 Structural Observation Structural observation is required for all 1709
concrete or masonry retaining and screen
walls.
7 General (shop drawing) Submit one set of reinforcing steel shop
(Deferred Submittal) drawings, which have been reviewed and
initialed by the Project Engineer, to be filed
with the city of Tigard before placement.
8 General Approved resolution of the above items shall
be incorporated into submittal plans before a
permit will be issued. Submit four (4) sets of
revised plans to the city of Tigard.