Loading...
Plans (118) BU P2019-00161 I I INI GENERAL NOTES ABBREVIATIONS PROJECT DESCRIPTION SHEET INDEX A0.01 -ALL ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL,AND PLUMBING WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL TENANT IMPROVEMENTS INCLUDES THE BUILDING OF NEW NON-STRUCTURAL PARTITIONS, DOORS, INTERIOR SHEET ORIGINAL AND LOCAL CODES AND ORDINANCES, WHETHER LISTED HEREIN OR NOT. NC AIR CONDITIONER MDF MEDIUM DENSITY FIBERBOARD GLAZING, & MILLWORK. ALL NEW OR REVISED HVAC, ELECTRICAL, PLUMBING AND LIFE SAFETY WORK WILL BE ADJ ADJACENT MAX MAXIMUM NO. SHEET TITLE ISSUE DATE A0.02-ANY&ALL GOVERNING LOCAL LABOR LAWS, REGULATIONS & REQUIREMENTS AND THOSE SETAS BUILDING REQUIREMENTS SHALL BE OBSERVED & FOLLOWED AS THEY DESIGN-BUILD AND SUBMITTED FOR PERMIT SEPARATELY. BUILDING IS "FULLY SPRINKLERED'. RELATE TO THIS PROJECT. ADMIN ADMINSTRATION MECH MECHANICAL A0.03- CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING PERMITS AND CERTIFICATE OF OCCUPANCY PERMIT AS WELL AS SEPARATE MECHANICAL, ELECTRICAL, AND AFF ABOVE FINISH FLOOR MEZZ MEZZANINE ARCHITECTURAL A D SKY PLUMBING PERMITS PRIOR TO AND DURING CONSTRUCTION. ALT ALTERNATE MFR MANUFACTURER SEPARATE PERMITS: A0.00 INDEX AND PROJECT INFORMATION 07.01.19 A0.04- MATERIALS, DIMENSIONS. AND OTHER CONDITIONS NOT OTHERWISE INDICATED IN THESE DRAWINGS SHALL BE ASSUMED AS HAVING THE SAME MEANING AS THOSE ALUM ALUMINUM MGR MANAGER A0.11 SPECIFICATIONS 07.01.19 MOST SIMILARLY DETAILED AND MORE FULLY DEFINED ELSEWHERE IN THE DRAWINGS. CONTRACTOR TO VERIFY W/ARCHITECT IN WRITING. APPROX APPROXIMATE MISC MISCELLANEOUS MECHANICAL DRAWINGS A0.12 SPECIFICATIONS 07.01.19 A0.05-THE EXTENT OF WORK SHALL BE LIMITED TO THAT INDICATED IN THE CONTRACT DOCUMENTS. NO ADDITIONAL WORK SHALL BE DONE WITHOUT WRITTEN APPROVAL OF ARCH ARCHITECTURAL MIN MINIMUM ELECTRICAL DRAWINGS A0.13 SPECIFICATIONS 07.01.19 OWNER. ANY ADDITIONAL WORK PERFORMED WITHOUT PRIOR WRITTEN APPROVAL BY OWNER SHALL BE AT THE CONTRACTOR'S EXPENSE. AVG AVERAGE PLUMBING DRAWINGS A0.06-THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING CONDITIONS PRIOR TO START OF WORK& DURING CONSTRUCTION AS NECESSARY TO NIC NOT IN CONTRACT A0.21 1ST FLOOR LIFE SAFETY PLAN 07.01.19 ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY ENTERING INTO A CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS FAMILIARITY WITH THE BLDG BUILDING NOM NOMINAL A0.22 2ND FLOOR LIFE SAFETY PLAN 07.01.19 SITE/FIELD CONDITIONS. BTM BOTTOM NTS NOT TO SCALE A1.01 1ST FLOOR CONSTRUCTION PLAN 07.01.19 A0.07- FLOOR TOLERANCE: IN LAYING OUT THE WORK TO BE COMPLETED, CONSIDERATION SHALL BE GIVEN TO VARIATIONS IN THE FLOOR LEVEL RESULTING FROM THE A1.02 2ND FLOOR CONSTRUCTION PLAN 07.01.19 CONSTRUCTION QUALITY AND LIVE AND DEAD LOADS IMPOSED ON THE STRUCTURE. FIELD VERIFICATIONS SHALL BE MADE OF CONDITIONS TO VERIFY CONSTRUCTION CAB CABINET OC ON CENTER A2.01 1ST FLOOR REFLECTED CEILING PLAN 07.01.19 TOLERANCES AND ALIGNMENT OF DOOR HEADS. OTHER HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT CONSTANT LEVEL AND SHALL NOT FOLLOW VARIATIONS IN CPT CARPET OPNG OPENING A2.02 2ND FLOOR REFLECTED CEILING PLAN 07.01.19 FLOOR PLANE. LEVEL FLOORS AS REQUIRED BY USING AN APPROVED LEVELING COMPOUND. CL CENTERLINE OPP OPPOSITE CODE ANALYSIS A2.51 ENLARGED REFLECTED CEILING PLAN 07.01.19 A0.08-THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, & EXISTING FINISHES THROUGHOUT CLG CEILING ALL PHASES OF CONSTRUCTION. NOISE, SECURITY, AND DUST BARRIERS BETWEEN CONSTRUCTION AREAS AND OCCUPIED AND PUBLIC AREAS SHALL BE MAINTAINED BY CLGHT CEILING HEIGHT PL PLASTIC LAMINATE A3.01 1ST FLOOR POWER AND COMMUNICATIONS PLAN 07.01.19 CONTRACTOR. CLR CLEAR PLAM PLASTIC LAMINATE A3.02 2ND FLOOR POWER AND COMMUNICATIONS PLAN 07.01.19 A0.09-THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING BUILDING CORRIDORS CLEAR OF PROJECT MATERIALS AND EQUIPMENT. CONC CONCRETE PLYWD PLYWOOD SCOPE OF WORK: TENANT IMPROVEMENT A4.01 1ST FLOOR FINISH PLAN 07.01.19 A0.10- GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK WHICH MAY NOT FALL UNDER THE JURISDICTION OF A SPECIFIED TRADE BUT IS REQUIRED FOR CONE CONFERENCE PT PAINT PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION. CONT CONTINUOUS A4.02 2ND FLOOR FINISH PLAN 07.01 19 A0.11 - NO MODIFICATIONS/REVISIONS/CHANGES SHALL BE UNDERTAKEN UNLESS SPECIFICALLY SO INSTRUCTED &APPROVED BY CLIENT. CORR CORRIDOR CONSTRUCTION TYPE: 111 B A5.01 1ST FLOOR FURNITURE PLAN 07.01.19 920 SW 6th Avenue A0.12 - CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS QTY QUANTITY OCCUPANCY: OFFICE (B) A5.02 2ND FLOOR FURNITURE PLAN 07.01.19 1 2th Floor BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION A6.01 INTERIOR ELEVATIONS 07.01.19 FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION. DIA DIAMETER REF REFRIGERATOR A0.13-THE INTENT OF THE CONTRACT DOCUMENTS IS TO EXCLUDE ALL MATERIALS WHICH CONTAIN KNOWN HAZARDOUS SUBSTANCES. THESE INCLUDE MATERIALS DIM DIMENSION REFRIG REFRIGERATOR NUMBER OF FLOORS: 2 STORIES ABOVE GRADE A6.11 1ST FLOOR MILLWORK ELEVATIONS 07.01.19 Portland, OR CONTAINING ASBESTOS, POLYCHLORINATED BIPHENYL(PCB), OR ANY OTHER KNOWN SUBSTANCES DETERMINED TO BE A HEALTH HAZARD BY THE UNITED STATES DN DOWN REQ'D REQUIRED A6.21 2ND FLOOR MILLWORK ELEVATIONS 07.01.19 T 678.491 .3773 ENVIRONMENTAL PROTECTION AGENCY (EPA)AND OTHER RECOGNIZED AGENCIES. IN STUDYING THE CONTRACT DOCUMENTS, AND AT ANY TIME DURING EXECUTION OF DR DOOR REV REVISION/REVISE T.I. S.Q. FOOTAGE: 1ST FLOOR: 3,730 SF A6.22 2ND FLOOR MILLWORK ELEVATIONS CONT. 07.01.19 THE WORK, THE CONTRACTOR SHALL AT ONCE REPORT TO THE ARCHITECT ANY MATERIALS CONTAINING HAZARDOUS SUBSTANCES THAT HE/SHE MAY DISCOVER. DO NOT DTL/DET DETAIL RM D 2ND FLOOR: 21,322 SF A7.01 PARTITION TYPES/PARTITION SECTIONS & DETAILS 07.01.19 www.asdsky.com PROCEED WITH INSTALLATION OF HAZARDOUS MATERIALS. DWG DRAWING ROOM A7.11 MILLWORK SECTIONS & DETAILS 07.01.19 A0.14- CONTRACTOR SHALL VERIFY PRESENCE OF HAZARDOUS MATERIALS WITH OWNER. ARCHITECT AND ITS CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE SAB SOUND ATTENUATION BATTS DISCOVERY, PRESENCE, HANDLING, REMOVAL, OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING EA EACH SAN SANITARY GOVERNING CODES A7.12 MILLWORK SECTIONS & DETAILS CONTINUED 07.01.19 BUT NOT LIMITED TO, ASBESTOS, POLYCHLORINATED BIPHENYL(PCB) OR OTHER TOXIC SUBSTANCES. EL ELEVATION SCHED. SCHEDULE 2014 OSSC &AMENDMENTS A7.13 MILLWORK SECTIONS & DETAILS CONTINUED 07.01.19 RECE1`1! Fr A0.15-WHERE PRODUCTS ARE SPECIFIED BY REFERENCE STANDARD OR IN DESCRIPTIVE MANNER WITHOUT MANUFACTURER'S NAME, MODEL NUMBER OR TRADE NAME, ELEV ELEVATOR SEC SECRETARY 2014 OMSC &AMENDMENTS A7.14 MILLWORK SECTIONS & DETAILS CONTINUED 07.01.19 i SF SQUARE FOOT 2014 OPSC &AMENDMENTS CONTRACTOR SHALL SELECT MATERIALS MEETING SPECIFIED REQUIREMENTS WHICH DO NOT CONTAIN KNOWN HAZARDOUS SUBSTANCES IN ANY FORM AND SUBMIT TO ENGR ENGINEER A7,21 CEILING SECTIONS& DETAILS 07.01.19 JUL 2019 SIM SIMILAR 2014 0ESC &AMENDMENTS ARCHITECT FOR APPROVAL. EQ EQUAL A7.41 FINISH MATERIAL DETAILS 07.01.19 A0.16- INSTALL ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT THAT EQUIP EQUIPMENT SPECS SPECIFICATIONS 2014 OEESC A8.01 DOOR SCHEDULE & DOOR TYPE DETAILS 07.01.19 CITY OF I‘ , THE SPECIFICATIONS HEREIN, WHERE MORE STRINGENT, SHALL BE COMPLIED WITH. EX EXISTING SQ SQUARE 2014 OFC &AMENDMENTS A0.17- IN MAKING REQUESTS FOR SUBSTITUTION, CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THAT MATERIALS REQUESTED FOR SUBSTITUTION ARE FREE OF SS STAINLESS STEEL REFERENCE3U1LDENCC DWI,: KNOWN HAZARDOUS SUBSTANCES IN ANY FORM. FCU FAN COIL UNIT STD STANDARD DA-REF DISABLED ACCESS STANDARDS (REFERENCE ONLY) 07.01.19 A0.18-WARRANTY SHALL BE EXTENDED FOR ALL CONSTRUCTION COMPONENTS, EQUIPMENT AND INSTALLATIONS INCLUDED IN THIS CONTRACT FOR A MINIMUM OF 1 YEAR FE FINISHED END STOR STORAGE REF-1 SITE PLAN (FOR REFERENCE ONLY) 07.01.19 FROM THE DATE OF SUBSTANTIAL COMPLETION. FE FIRE EXTINGUISHER SW SWITCH A0.19- GC SHALL RE-EXECUTE ANY WORK THAT FAILS TO CONFORM TO THE DRAWINGS/DETAILS AS SHOWN AND ANY DEFECTS DUE TO FAULTY MATERIALS OR WORKMANSHIP FEC FIRE EXTINGUISHER TBD TO BE DETERMINED WHICH APPEAR WITHIN A PERIOD OF ONE (1) YEAR. FL CABINET T-STAT THERMOSTAT A0.20- SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT IN TRIPLICATE FOR REVIEW. SHOP DRAWINGS ENHANCE THESE SPECIFICATIONS: APPROVAL OF SHOP DRAWINGS FRT FLOOR TV TELEVISION SHALL NOT RELEASE CONTRACTOR FROM RESPONSIBILITY FOR THE WORK AS SPECIFIED, FURN FIRE RETARDENT TREATED TYP TYPICAL A0.21 -THESE DOCUMENTS INDICATE MATERIALS AND METHODS OF CONSTRUCTION TO ESTABLISH STANDARDS OF QUALITY AND/OR PERFORMANCE. OTHER MATERIALS GA GAUGEURE ACCESSIBLE IMPROVEMENTS AND/OR METHODS WILL BE CONSIDERED BY THE ARCHITECT FOR ACCEPTANCE PROVIDED THAT THEY DO NOT AFFECT THE VISIBLE APPEARANCE. MATERIALGALV GALVANIZED UNO UNLESS NOTEDOTHERWISE SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT IN WRITING PRIOR TO ORDERING AND/OR FABRICATION. GWB GYPSUM WALL BOARD A0.22 -ALL REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND WILL BE CONSIDERED ONLY IF BETTER SERVICE FACILITIES,A MORE GYP BD GYPSUM BOARD VCT VINYL COMPOSITION TILE ADVANTAGEOUS DELIVERY DATE, OR LOWER PRICE WITH CREDIT TO THE OWNER IS PROVIDED WITHOUT SACRIFICING QUALITY, APPEARANCE AND FUNCTION. UNDER NO VENT VENTILATION NEW ADA HEIGHT TRANSACTION COUNTER AT RECEPTION DESK $5,500.00 CIRCUMSTANCES WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT VERTICAL NEW ADA HEIGHT MILLWORK AT BREAKRODMS $43,000.00 SPECIFIED. HDW HARDWARE VEST VESTIBULE NEW ADA HEIGHT MILLWORK AT COPY ROOMS $12,500.00 T H E AO.23- CONTRACTOR SHALL SUBMIT TO THE ARCHITECT, IMMEDIATELY FOLLOWING DIRECTIVE TO PROCEED WITH WORK, CONFIRMATION WITH DELIVERY DATES FOR ORDERS HVAC HEATING, VENTILATING, AIR LIGHTING OCCUPANCY SENSORS THROUGHOUT $24,000 00 OF MATERIALS AND EQUIPMENT AND ANY LONG LEAD TIME ITEMS. CONDITIONING VIF VERIFY IN FIELD A0.24- DAMAGE: CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIRS OF ANY ACCIDENTAL DAMAGE HE INFLICTS UPON THE EXISTING WORK WHICH WILL REMAIN. IF FORVWEC VINYLERIVIWITH EQUIPMENT PARTNERS ANY REASON DAMAGE TO EXISTING WORK OR UTILITIES IS CONSIDERED TO BE UNAVOIDABLE, SUBMIT WRITTEN NOTIFICATION OF THIS BEFORE SIGNING THE CONTRACT. IN INT INTERIOR VWE VERIFY WITH INSUL INSULATION THE ABSENCE OF SUCH NOTIFICATION, CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR DAMAGE AND THE COSTS OF SATISFACTORILY REPAIRING OR REPLACING W/ WITH GROUP DAMAGED WORK. JAN JANITOR WC WALLCOVERING A0.25- FINAL CLEANING AT COMPLETION SHALL INCLUDE DUSTING OF ALL FINISHED SURFACES, VACUUMING, REMOVAL OF SPOTS, STAINS, LABELS, FINGERPRINTS, SPILLS, AND JUNC JUNCTION CLEANING OF ALL INTERIOR GLASS. WD WOOD A0.26- JOB SITE CLEAN-UP SPECIFIED IN 0.25 SHALL CONTINUE BEYOND DATE OF SUBSTANTIAL COMPLETION TO MOVE-IN DAY AND SHALL INCLUDE REMOVAL OF ACCUMULATED LAB LABORATORY W/O WITHOUT DEBRIS RESULTING FROM WORK BY TELECOMMUNICATIONS CONTRACTORS AND OTHER VENDORS UNDER CONTRACT TO THE OWNER. (NOTE:FURNITURE PACKING LAM LAMINATED MATERIALS WILL BE RESPONSIBILITY OF FURNITURE VENDOR.) LAV LAVATORY 11850 SW 67TH AVE. A0.27 - FIRE RATED PARTITIONS SHALL BE NOTED IN STENCIL ABOVE FINISHED CEILING PER APPLICABLE CODE. LVT LUXURY VINYL TILE A0.28 - GENERAL CONDITIONS (AIA DOCUMENT A201)APPLIES TO THIS PROJECT AND ISA PART OF THIS CONTRACT. CITY OF TIGARD SUITE 100 A0.29 -VERIFY SPECIFIC SECURITY REQUIREMENTS WITH TENANT. Rx. I'X. FOR CODE COMPLIANCE A0.30ABOLOCATION F CONTRACTOR S OAESTHETIC AS O AS REQUIRED BY CODE. • PORTLAND, OR SPRINKLERS SHALLCENTERED WITHIN EACH CEILING WITH TO PROVIDE A UNIFIED, CONSISTENT AND ARRANGEMNT HEADS AL BE WHITE FUSH TYPE OR Approved: BUILDING STANDARD IF EQUAL OR BETTER. ARCHITECTURAL SYMBOLS PROJECT TEAM OTC: i i - 97223 Permit#: 13up,aOJ J - Os) 1' I Address: ! 1 R,-'o �C .., g71f] PROPERTY MANAGER: PACIFIC NW PROPERTIES ROOM NAME 6600 SW 105TH AVENUE, SUITE 175 Suite#: 00 C` NM BEAVERTON, OR 97008 By: Date 7-j ) ROOM TAG -411111111.- ELEVATION INDICATIOR: PHONE: 503.626.3500 XX!XX.XX Al-1 CONTACT. TED RAMSEY CO�� EL NUMBER/SHEET NUMBER ALTERNATE NOTE OcviC. ARCHITECT: ASDISKY I SECTION INDICATOR: /1 REVISION NUMBER 920 SW 6TH AVENUE, 12TH FLOOR PORTLAND, OR 97204 DRAWING NUMBER 678.491 3773 SHEET NUMBER CODED NOTE CONTACT: ABBY ROLLA II ENLARGED PLAN/DETAIL: 1 1-71-- SIM WINDOW TYPE NOTE CLIENT: THE PARTNERS GROUP 1 I DRAWING NUMBER DOOR TYPE FRAME TYPE 11740 SW 68TH PARKWAY, STI. 200 OFFICE COPY A0/ SHEET NUMBER HARDWARE SET PORTLAND, OR 97223 q� pp COPI PHONE: 503.726-5724 oFFice CONTACT: DOREEN BARNHOUSE ELEVATION HEIGHT T.1 EQUIPMENT NOTE .4 0'-0" A.F.F. INDICATOR: W BO CEILING PROJECT MANAGER: CRESA HEIGHT 317 SW ALDER ST., SUITE 1050 DESCRIPTION PORTLAND, OR 97204 ALIGN PHONE: 503.886,8665 ,,f ' ,x�r �D i ALIGN ELEMENTS CONTACT: JAMES VIETZKE T,`.,, ` CONIPLTANCE �,. . � l 1. . r_. CONTRACTOR: SWINERTON `'1' i I 342 SW SECOND AVE t" I ......... .. ..... ...... . .1 PHONE: 503.224.6888 _ _ CONTACT: ALANA ARMSTRONG A,..•_� -. - o s, 7: 1G�' COpy DEFERRED �' --__-- -- . ...�. _ �..._ Fire Sprinkler \T Fire Alarm 1-t-- '��`'�Ai Mechanical \`\'/ t (`r tt Plumbing VALIDITY OF PERMIT N� Electrical - THE ISSUANCE OFA PERMIT /� Truss Engineering D �L BASED ON CONSTRUCTION �1 Shop Drawings - DOCUMENTS AND OTHER OSEPHA REMLING:r...21.Other DATA SHALL NOT PREVENTTHE CODE OFFICIAL FROM6526REQUIRING THI CORRECTION 10 • �qNFKANCISCtG.OF ERRORS. OSSC 105.4cn1 O • s MOUNTING HEIGHTS KEY PLANS LOCATION MAP •SW Plne St aaroecue , 'F Comfort Suites Southwe" This drawing is the property of Associated Banning's Restaurant Y.11. L A RIDGE Space Design, Inc. and is not to be SCOPE OF WORK SCOPE OF WORK &Pie House reproduced or copied in whole or part. It is ALIGN CENTER OF ALL DEVICES SW Spnice St cr not to be used on any other project and is to I WHEN LOCATED TOGETHER Discount Tire be returned upon request. Scales as stated I Fred Meyer ,, • 0 herein are for reference only as normal VISUAL ALARM \ y s 3 ,� r reproduction processes may alter the OUTLET MOUNTED ABOVE 11 9 Portland \ j•iiiiti®SI U. `' U accurac of ori final drawin s. BACKSPLASH OR COUNTER 1 // �, Communit Associated Space Design, Inc. 2016 (WHERE SPECIFIED) 7- L r K :"...,,, y College \ / TOP OF COUNTER OR r q J�'' it w McDonald's g Sylvania BACK SPLASH tit '', /* _ w �, a Taco Bell p Le s r o TOP OF FIRE EXTINGUISHER _illi ', 1� K , 4 ' , Oregon Education $ e ;, 5 n, -- City Park III: Lu �' HANDLE. COORDINATE WITH CABINET AND FIRE Fk. swPrarr�est Association r 1 rice res p �r J EXTINGUISHER MFR 1 ► i • �, - T co g =�� I Q / '`� , _ - -1--- - 1 , \ Regal Tigard ' sw Atlanta st a SW Hames St O 4" MIN b --, ilif CO a SW1 WinCo Foods � ** I� ,� Wholesale 11850 Southwest 10 / Rent A Car 67th Avenue -\111 .. t ra44----- REFER TDii _ H i SWKruseRidgeDs 'ly1'-0„ SCHEDULE --- , ct. sw Drtrnaum st esser Rd Jefferson PkEQ.�EQ. I --__ -] 1Landmark Ford Lincoln 4TELEPHONE _ p 9 m y Bay Pointer Walmart Su ercenter .�.- 7._\ _�` °' i ta' 0 07.01.19 ISSUEDFOR PERMIT FACE OF DOOR FRAMEJ - ykart Indoor Racing QNO: DATE: REMARKS: _ _ 4�_ � COAT HOOK AT INSIDE sw FrankEsn st1. camOF OFFICE DOORSREVISIONS: DRAWING TITLE: o O ,; - a-= THERMOSTAT Lowes Home s«anWo��ar ° ,� CR K L Oswe o Cove A artmcimprovementLIGHT SWITCH I- I- INFORMATION w0 o DOOR LEVER Artistic Auto Body 9' \ yli. st Pacific Parkway Center V rotr 07 ro PROJECT NO.: ISSUE DATEeI\ CARD READER a 2HOZI.00 07.01. 9? ? _ DRAWN BY: CHECKED BY: t17 . .................. ..... .... ...... .... .. . .......... . ... . .................. ....... ....... . ....... .. ...* :ALIMENSIONS SHALL MEET LOCAL ACCESSIBILITY CDE. CCT ARCHITECT WITH ANdi FLOOR 2ND FLR CIT`>� OF I IGARD HF AR cn QUESTIONS OR CONFLICTS REGARDING MOUNTING HEIGHTS. Approved by Planning SHEET NUMBER Et Date: -3-11 o c..' co Initials: ScA0.00 ti 1 I t I GENERAL REQUIREMENTS GENERAL FINISH NOTES GYPSUM WALL BOARD (CONT.) HOLLOW METAL DOOR FRAMES (CONT.) ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, REGULATIONS, ORDINANCES, ETC.,OF ALL FEDERAL, STATE, COUNTY OR SELECTED MATERIALS ARE SHOWN BY ALLOWANCES. ALLOWANCES SHALL BE FOR VARIATIONS IN MATERIALS ONLY. ALL WHERE FEASIBLE, USE THE SAME FASTENERS TO ANCHOR TRIM ACCESSORY FALNGES AS REQUIRED TO FASTEN GYPSUM BOARD PREPARE HOLLOW METAL UNITS TO RECEIVE MORTISED AND CONCEALED FINISH HARDWARE, INCLUDING CUTOUTS, MUNICIPAL ENTITIES HAVING JURISDICTION OVER THE PROJECT. ALL APPLICABLE REQUIREMENTS OF THESE REGULATIONS SHALL INSTALLATION AND RELATED PRODUCTS TO ACCOMPLISH THE COMPLETE ASSEMBLY SHALL BE INCLUDED IN THE CONTRACT TO THE SUPPORTS. OTHERWISE, FASTEN FLANGES TO COMPLY WITH MANUFACTURER'S RECOMMENDATIONS. REINFORCING, DRILLING,AND TAPPING IN ACCORDANCE WITH FINAL FINISH HARDWARE SCHEDULE AND TEMPLATES BE FOLLOWED AT ALL TIMES, REGARDLESS OF WHETHER THEY HAVE BEEN SPECIFICALLY REFERENCED IN THESE DOCUMENTS OR PRICING BY THE CONTRACTOR. PROVIDED BY HARDWARE SUPPLIER. NOT. CONFLICTS IN THESE REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING SOUND ATENUATION BLANKETS SHALL BE INSTALLED PRIOR TO GYPSUM BOARD WHERE INDICATED UNLESS READILY INSTALLED WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITSREQUIRED BY ALL ENTITIES HAVING RETURN UNUSED, UNOPENED MATERIALS TO THE MANUFACTURER OR SUPPLIER FOR CREDIT TO THE OWNER AFTER INSTALLATION AFTER BOARD HAS BEEN INSTALLED. REINFORCE HOLLOW METAL UNITS TO RECEIVE SURFACE-APPLIED HARDWARE. DRILLING OR TAPPING FOR SURFACE- JURISDICTION OVER THE PROJECT AND SHALL INCLUDE THE COST OF THOSE FEES IN THE CONTRACT. HAS BEEN COMPLETED AND ACCEPTED. UNUSED MATERIALS FROM OPEN PACKAGES ARE TO BE TURNED OVER TO THE OWNER AS APPLIED FINISH HARDWARE MAY BE DONE AT PROJECT SITE.THROUGH BOLTING WILL NOT BE PERMITTED. ATTIC STOCK. JOINT TREATMENT SHALL BE APPLIED AT GYPSUM BOARD JOINTS(BOTH DIRECTIONS); FLANGES OF CORNER BEAD, EDGE TRIM,AND A ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE TERMS OF THE LEASE AND APPLICABLE BUILDING STANDARD CONTROL JOINTS; PENETRATIONS; FASTENER HEADS, SURFACE DEFECTS AND ELSEWHERE AS REQUIRED TO PREPARE WORK FOR INSTALLER SHALL EXAMINE THE SUBSTRATE AND CONDITIONS UNDER WHICH HOLLOW METAL WORK IS TO BE INSTALLED. SPECIFICATIONS. WORKMANSHIP AND MAINTAINING STANDARDS OF QUALITY SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. COMPLY WITH THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS FOR INSTALLATION FOR ALL PRODUCTS AND DECORATION. NOTIFY THE CONTRACTOR, IN WRITING, OF ANY CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF WORK. THE CONTRACTOR SHALL PROVIDE ALL WORK SHOWN IN THE CONTRACT DOCUMENTS AND IS REQUIRED TO PROVIDE A COMPLETE, MATERIALS USED IN THE PROJECT TO THE EXTENT THAT THOSE INSTRUCTIONS ARE MORE EXPLICIT AND/OR MORE STRINGENT FINISHED INSTALLATION, UNLESS OTHERWISE NOTED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ACQUAINT HIMSELF WITH THAN THE REQUIREMENTS IN THE CONTRACT DOCUMENTS. PREFILL OPEN JOINTS AND ROUNDED OR BEVELED EDGES USING SETTING-TYPE JOINT COMPOUND. INSTALLER SHALL COMPLY WITH PROVISIONS OF SI-105"RECOMMENDED ERECTION INSTRUCTIONS FOR STEEL FRAMES," ALL SUCH TENANT AND BUILDING STANDARDS REGARDLESS OF WHETHER THEY HAVE BEEN SPECIFICALLY REFERENCED IN THESE UNLESS OTHERWISE NOTED. DOCUMENTS OR NOT. INSPECT MATERIALS OR EQUIPMENT IMMEDIATELY UPON DELIVERY AND AGAIN PRIOR TO INSTALLATION. REJECT DAMAGED AND/OR APPLY JOINT TAPE AT JOINTS BETWEEN GYPSUM BOARDS, EXCEPT WHERE TRIM ACCESSORIES ARE INDICATED. DEFECTIVE ITEMS. FIRE-RATED FRAMES SHALL BE INSTALLED IN ACCORDANCE WITH NFPA STANDARD NO. 80. THE'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION'AIA DOCUMENT A201, 1987 EDITION SHALL GOVERN THIS WORK, CAULK GAPS WHERE INTERSECTION OF CONSTRUCTION ELEMENTS IS NOT CRISP AND CONSISTENT AS APPLICABLE, UNLESS UNLESS OTHERWISE NOTED. PROVIDE APPROPRIATE ATTACHMENT AND CONNECTION DEVICES AND METHODS NECESSARY FOR SECURING THE WORK. SECURE OTHERWISE NOTED. EXCEPT ON WEATHERSTRIPPED FRAMES, DRILL STOPS SHALL BE DRILLED TO RECEIVE 3 SILENCERS ON STRIKE JAMBS OF ALL WORK TRUE TO LINE AND LEVEL.ALLOW FOR BUILDING EXPANSION AND BUILDING MOVEMENT. SINGLE-DOOR FRAMES AND 2 SILENCERS ON HEADS OF DOUBLE-DOOR FRAMES. IN THE CASE OF CONFLICTS WITHIN THESE CONSTRUCTION DOCUMENTS,THE MOST STRINGENT REQUIREMENT SHALL APPLY. FINISH INTERIOR GYPSUM WALLBOARD BY APPLYING JOINT COMPOUNDS IN 3 COATS (NOT INCLUDING PREFILL OF OPENINGS IN PROVIDE UNIFORM JOINT WIDTHS IN EXPOSED WORK. ARRANGE JOINTS IN EXPOSED WORK TO OBTAIN THE BEST VISUAL EFFECT. BASE),AND SAND BETWEEN COATS AND AFTER LAST COAT. ONLY ONE COAT IS REQUIRED ON CONCEALED DRYWALL IN METAL STUD PARTITIONS, INSTALL AT LEAST THREE(3)WALL ANCHORS PER JAMB AT HINGE AND STRIKE LEVELS. IN THESE CONTRACT DOCUMENTS SHALL BE CONSIDERED COMPLIMENTARY AND WHATEVER REQUIREMENTS ARE REQUIRED BY ANY CONSTRUCTION. CLOSED STEEL STUD PARTITIONS,ATTACH WALL ANCHORS TO STUDS WITH SCREWS. SHALL BE BINDING AS IF REQUIRED BY ALL. RECHECK MEASUREMENTS AND DIMENSIONS BEFORE STARTING EACH INSTALLATION. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS, IN A MANNER SUITABLE TO INSTALLER,WHICH ENSURES GYPSUM IMMEDIATELY AFTER ERECTION OF FRAMES, SAND SMOOTH ANY RUSTED OR DAMAGED AREAS OF PRIVE COAT AND APPLY THE CONTRACTOR SHALL ARRANGE FOR ELEVATOR OR OTHER HOISTING FACILITIES FOR MATERIALS AS WELL AS PARKING AND THE CONTRACTOR SHALL ENSURE THAT NO PART OF THE CONSTRUCTION, COMPLETED OR IN PROGRESS IS SUBJECT TO HARMFUL, DRYWALL CONSTRUCTION BEING WITHOUT DAMAGE OR DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION. TOUCH-UP OF CAMPATIBLE AIR-DRYING PRIMER. LOADING FACILITIES WITH THE BUILDING MANAGEMENT. THE CONTRACTOR SHALL PAY ALL COSTS FOR DELIVERY AND/OR HANDLING DANGEROUS, OR DAMAGING EXPOSURE DURING THE CONSTRUCTION PERIOD. SUCH EXPOSURE INCLUDES BUT IS NOT LIMITED TO OF MATERIALS. THE FOLLOWING: EXCESSIVE HIGH OR LOW TEMPERATURES, EXCESSIVE HIGH OR LOW HUMIDITY,WATER,ABRASION, LIGHT, CHECK AND READJUST OPERATING FINISH HARDWARE ITEMS IN HOLLOW METAL WORK JUST PRIOR TO FINAL INSPECTION. 920 SW 6th Avenue STAINING, UNPROTECTED STORAGE,THEFT, FIRE,OR VANDALISM. FIRESTOPPING LEAVE WORK IN COMPLETE AND PROPER OPERATING CONDITION. REMOVE AND REPLACE DEFECTIVE WORK, INCLUDING ALL ARRANGEMENTS FOR CONSTRUCTION PERSONNEL ENTERING THE BUILDING DURING OR AFTER WORKING HOURS, MATERIALS FRAMES WHICH ARE WARPED, BOWED OR OTHERWISE UNACCEPTABLE. 1 2th Floor DELIVERY,STORAGE, SECURITY, DEBRIS REMOVAL,ETC.,SHALL BE MADE WITH THE BUILDING MANAGEMENT. SUBMIT FULL SIZE AND FULLY FABRICATED SAMPLES,CURED AND FINISHED AS SPECIFIED WITH THE MATERIAL OR PRODUCT SPECIFIED. SAMPLES INCLUDE PARTIAL SECTIONS OR MANUFACTURED OR FABRICATED COMPONENTS, CUTS OF MATERIALS, FIRESTOPPING SHALL COMPLY WITH THE STANDARDS REQUIRED BY ASTM E814-88"STANDARD TEST METHOD FOR FIRE TESTS OF Portland, OR "R H FIRESTOPS"AND SHALL COMPLY WITH UL 1479"FIRE TESTS OFTHROUG -PENETATION FtRESTOPS. NO WORK INVOLVING EXTRA COST BEYOND THE TERMS OF THE LEASE AND THE TENANT CONSTRUCTION DOCUMENT'S OF THE COLOR RANGE SETS AND SWATCHES SHOWING COLOR TEXTURE AND PATTERN. THROUGH-PENETRATIONT 678.49 .3775 PREMISES AND BUILDING STANDARD MATERIALS SHALL BE COMMENCED WITHOUT PRIOR APPROVAL BY TENANT CONTRACT,AND FIRESTOPPING SYSTEMS SHALL CONFORM TO BOTH FLAME(F)AND TEMPERATURE(T)RATINGS AS REQUIRED BY LOCAL BUILDING ALUMINUM DOOR FRAMES/DOORS THE ARCHITECT, IF APPLICABLE. WHERE VARIATION IN COLOR PATTERN AND TEXTURE OR OTHER CHARACTERISTICS ARE INHERENT IN THE MATERIAL, SUBMIT CODE AND AS TESTED BY NATIONALLY ACCEPTED TEST AGENCIES PER ASTM E814 AND UL 1479 FIRE TESTS IN A CONFIGURATION WWW.aSdSky.co m MULTIPLE UNITS(NOT LESS THAN 3)TO EXHIBIT THE FULL RANGE OF VARIATION. PRIOR TO CONSTRUCTION,THE CONTRACTOR,AND HIS SUBCONTRACTORS, SHALL PROVIDE UNIT PRICES FOR ALL WORK SHOWN. THAT IS REPRESENTATIVE OF FIELD CONDIDTIONS. THE F RATING MUST BE A MINIMUM OF ONE HOUR, BUT NOT LESS THAT THE FIRE 1.1 SECTION INCLUDES SUCH UNIT PRICING SHALL BE REQUIRED TO BE SUBMITTED PRIOR TO SUBMITTAL OF THE FIRST APPLICATION FOR PAYMENT. PROVIDE ALL MANUFACTURER'S STANDARD WARRANTIES FOR THE VARIOUS SPECIFIED MATERIALS TO THE OWNER. IF WORK RESISTANCE RATING OF THE ASSEMBLY BEING PENETRATED.T RATING,WHEN REQUIRED BY CODE AUTHORITY, SHALL BE BASED A. PREFINISHED ALUMINUM DOOR FRAMES FOR INTERIOR USE.ON MEASUREMENT OF THE TEMPERATURE RISE ON PENETRATING ITEMS. THE FIRE TEST SHALL BE CONDUCTED WITH A MINIMUM B. PREFINISHED ALUMINUM FRAMING SYSTEMS FOR INTERIOR USE. FAILURE TO SUBMIT THE UNIT PRICING SHALL BE CONSIDERED GROUNDS FOR REJECTION OF THE INITIAL APPLICATION FOR COVERED BY A WARRANTY HAS FAILED AND BEEN CORRECTED BY REPLACEMENT, REINSTATE THE WARRANTY BY WRITTEN POSITIVE PRESSURE DIFFERENTIAL OF 0.01"OF WATER COLUMN. C. PREFINISHED ALUMINUM GLASS DOORS FOR INTERIOR USE. PAYMENT. SUCH UNIT PRICES SHALL BE GOOD FOR THE DURATION OF THE PROJECT AND SHALL BE USED AS THE BASIS FOR ALL ENDORSEMENT. THE REINSTATED WARRANTY SHALL BE EQUAL TO THE ORIGINAL WARRANTY WITH AN EQUITABLE ADJUSTMENT CHANGES TO THE WORK. FOR DEPRECIATION. FIRESTOPPING SHALL BE INSTALLED IN ALL OPENINGS IN FIRE-RATED FLOOR AND WALL ASSEMBLIES, BOTH BLANK (EMPTY)AND 1.2 RELATED SECTIONS THE CONTRACTOR SHALL SCHEDULE AND PERFORM ALL WORK SO AS NOT TO DISTURB ANY TENANT IN THE BUILDING AND SHALL THE CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY FROM DATE OF SUBSTANTIAL COMPLETION COVERING DEFECTS THOSE ACCOMMODATING PENETRATING ITEMS SUCH AS CABLES, CONDUITS, PIPES, DUCTS, ETC. A. SECTION 08211 FLUSH WOOD DOORS. IDENTIFY ALL OVERTIME COSTS REQUIRED TO COMPLETE THE WORK IN HIS BID. ARISING FROM BOTH MATERIALS AND WORKMANSHIP FOR WORK PERFORMED BY THE CONTRACTOR AND HIS SUBCONTRACTORS. B.SECTION 08710 DOOR HARDWARE. FIRESTOPPING MATERIALS AND SYSTEMS SHALL BE CAPABLE OF CLOSING OR FILLING THROUGH OPENINGS CREATED BY THE C. SECTION 08800 GLASS AND GLAZING. THE CONTRACTOR SHALL PREPARE A COMPLETE CONSTRUCTION SCHEDULE TO INCLUDE WORK TO BE PERFORMED BY THE ALL EXPOSED SURFACES SHALL BE FINISHED. WHERE THE FINISH IS NOT INDICATED OR UNCLEAR,VERIFY THE FINISH WITH THE BURNING OR MELTING OF COMBUSTIBLE PIPES, CABLE JACKETING, OR PIPE INSULATION MATERIALS, OR OPENINGS CREATED BY TENANTS VENDORS TO BE SUBMITTED WITHIN ONE WEEK OF AWARD OF THE CONTRACT. ARCHITECT. DEFLECTION OF SHEET METAL DUE TO THERMAL EXPANSION(ELECTRICAL OR MECHANICAL DUCTWORK). 1.3 REFERENCES A.AAMA 603.8-VOLUNTARY PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR PIGMENTED ORGANIC COATINGS SUBSTITUTIONS SHALL BE ALLOWED ONLY IF THE SPECIFIED ITEMS CANNOT BE INSTALLED WITHIN THE TENANT'S MOVE-IN SCHEDULE THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING THE DELIVERY DATE OF ALLFINISH MATERIALS AS APPLICABLE DURING FIRESTOPPING MATERIAL SHALL BE ASBESTOS-FREE AND SHALL NOT INCORPORATE NOR REQUIRE THE USE OF HAZARDOUS ON EXTRUDED ALUMINUM. AND ONLY WITH THE APPROVAL OF THE WITHIN THE TENANT'S MOVE-IN SCHEDULE AND ONLY WITH THE APPROVAL OF THE THE BIDDING PERIOD AND SHALL SUBMITTHOSE DATES IN WRITING WITH HIS BID. SOLVENTS. B. 607.1 -VOLUNTARY GUIDE SPECIFICATION AND INSPECTION METHODS FOR CLEAR ANODIZE FINISHES FOR SELECTION AND APPROVAL OF ALL SUBSTITUTED ITEMS PRIOR TO SUBMISSION OF HIS BID. IT IS THE CONTRACTOR'S ARCHITECTURAL ALUMINUM. RESPONSIBILITY TO ENSURE AND TO DEMONSTRATE THAT ALL SUBSTITUTIONS USED IN THE WORK COMPLY WITH THE CONTRACT SUBMIT TO THE ARCHITECT FOR REVIEW PRIOR TO INSTALLATION,THREE 8 1/2"X 11"SAMPLES OF ALL FINISHES FROM ACTUAL FIRESTOPPING MATERIALS SHALL NOT SHRINK UPON DRYING AS EVIDENCED BY CRACKING OR PULLING BACK FROM CONTACT C.MMA 608.1 -VOLUNTARY GUIDE SPECIFICATION ANS INSPECTIONS METHODS FOR ELECTROLYTICALLY DEPOSITED COLOR SURFACES.SHOULD A SUBSTITUTED PRODUCT FAIL TO PERFORM FOR ANY REASON,WHERE THE ORIGINALLY SPECIFIED PRODUCT DYELOTS TO BE USED. APPLY FINISH SAMPLES TO SAME SUBSTRATA AS WILL OCCUR IN THE PROJECT. SUBMIT SEAMING SURFACES. ANODIC FINISHED FOR ARCHITECTURAL ALUMINUM. WOULD HAVE,THE CONTRACTOR SHALL PERFORM ALL THE WORK NECESSARY TO INCORPORATE THE ORIGINALLY SPECIFIED DIAGRAMS AS APPLICABLE. PRODUCT AT NO ADDITIONAL COST. DO NOT USE ANY FIRESTOP PRODUTS WHICH,AFTER CURING, DISSOLVE IN WATER. 1.4 SUBMITTALS VERIFY FINISHES WITH THE ARCHITECT IN THE FIELD PRIOR TO INSTALLATION. A. SUBMIT UNDER PROVISIONS OF SECTION 01300. FIRESTOPPING MATERIALS SHALL BE MANUFACTURED BY ONE MANUFACTURER TO THE MAXIMUM EXTENT POSSIBLE. B. PRODUCT DATA: MANUFACTURER'S FABRICATION AND INSTALLATION INSTRUCTIONS. THE CONTRACTOR SHALL CHECK AND VERIFY ALL EXISTING CONDITIONS AND THE CONTRACTOR SHALL CHECK AND VERIFY ALL EXISTING CONDITIONS AND BETWEEN THE CONTRACT DOCUMENTS AND THE FIELD CONDITIONS PRIOR TO COMMENCING THE WORK. FINISH MATERIAL SUBSTRATA SHALL BE FREE OF IMPERFECTIONS AND MARKINGS SUBJECT TO BLEED-THROUGH. C. SHOP DRAWINGS:ALL FIRESTOP PRODUCTS AND SYSTEMS SHALL BE DESIGNED AND INSTALLED SO THAT THE BASIC SEALING SYSTEM WILL ALLOW 1. PROVIDE STANDARD INSTALLATION DETAILS FOR TYPICAL ARCHITECTURAL CONDITIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTRICTING AND CONTAINING DUST, DEBRIS AND FUMES GENERATED BY THE REPAIR, REFINISH AND PREPARE AS APPLICABLE, EXISTING SURFACES TO RECEIVE NEW OR EXISTING MATERIALS. THIS INCLUDES, THE FULL RESTORATION OF THE THERMAL AND FIRE RESISTANCE PROPERTIES OF THE BARRIER BEING PENETRATED WITH MINIMAL 2. PROVIDE DETAILS ON CONNECTIONS TO SPECIAL CONSTRUCTION AND OTHER CUSTOM FEATURES. DEMOLITION AND CONSTRUCTION BY MEANS OF TEMPORARY PARTITIONS, BARRIERS, FILTERS, SCREENS, ETC.AS REQUIRED SO BUT IS NOT LIMITED TO FLOORING, DOORS&FRAMES, BASE BUILDING PARTITIONS, FLOOR SLABS, CEILINGS, ETC.AS REQUIRED, REPAIR IF PENETRANTS ARE SUBSEQUENTLY REMOVED. D. SELECTION SAMPLES: PROVIDE ALUMINUM CHIPS IN FULL RANGE MANUFACTURER'S STANDARD FINISHED FOR THE THAT ADJOINING TENANTS IN THE BUILDING WILL NOT BE DISTURBED. EMPHASIS SHALL BE PLACED ON PREVENTING THE SPREAD OF UNLESS NOTED OTHERWISE. ARCHITECT'S COLOR SELECTION. PARTNERS DUST, DEBRIS AND FUMES THROUGH THE HVAC SYSTEM. ALL THROUGH-PENETRATIONS,CONSTRUCTION GAPS,JOINTS AND THROUGH OPENINGS OCCURRING,ADJACENT TO,OR BETWEEN E.VERIFICATION SAMPLES: PROVIDE TWO SAMPLES OF EACH TYPE OF FRAMING MEMBER REQUIRED,NOT LESS THAN 12 - /�► THE FIRE-RATED FLOOR/CEILINGS AND WALLS SHALL BE FIRESTOPPED AS PER THE REQUIREMENTS OF THIS SPECIFICATION. INCHES LONG, IN SELECTED FINISH. GROUP ' DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. GYPSUM WALL BOARD ALL COMBUSTIBLE PENETRANTS(I.E. NON-METALLIC PIPES OR INSULATED METALLIC PIPES)SHALL BE FIRESTOPPED USING 1.5 QUALITY ASSURANCE G RO U P THE CONTRACTOR SHALL IMMEDIATELY ANALYZE THE CONTRACT DOCUMENTS AND REPORT ANY DISCREPANCIES TO THE GYPSUM WALL BOARD AND STEEL FRAMING INSTALLATION,APPLICATION,AND FINISHING SHALL COMPLY WITH ASTM C754 AND PRODUCTS AND SYSTEMS TESTED IN A CONFIGURATION REPRESENTATIVE OF THE FIELD CONDITION. A. MANUFACTURER: PROVIDE ALUMINUM FRAMES MANUFACTURED BY A SINGLE FIRM SPECIALIZING IN PRODUCTION OF THIS ARCHITECT. THE CONTRACTOR SHALL BE REQUIRED TO CORRECT ANY DEFECTIVE WORK CAUSED BY WORK DONE AS A RESULT OF ASTM C840 STANDARDS AND SHALL BE IN ACCORDANCE WITH THE CURRENT VERSION OF UNITED STATES GYPSUM-GYPSUMTYPE OF WORK FOR A MINIMUM OF FIVE YEARS. INCONSISTENCIES OR DISCREPANCIES IN THE DRAWINGS WHEN CLARIFICATION FROM THE ARCHITECT HAS NOT BEEN SOUGHT. CONSTRUCTION HANDBOOK. SUBMIT MANUFACTURER'S PRODUCT LITERATURE FOR EACH TYPE OF FIRESTOP MATERIAL TO BE INSTALLED. LITERATURE SHALL B. FIRE RATED ASSEMBLIES: INDICATE PRODUCT CHARACTERISTICS,TYPICAL USES, PERFORMANCE AND LIMITATION CRITERIA,AND TEST DATA. 1. IN LOCATIONS WHERE FIRE RATED ALUMINUM FRAMES THAT HAVE BEETED INGS ARE N TESTED ANDE�ERTIDFIOR REQUIREDED FOR SPECT BY EXPOSURE BY AN AGENCY PROVIDE FIRE Q ARCHITECTURAL DOCUMENTS SHALL HAVE PRECEDENCE OVER ENGINEERING DOCUMENTS. HOWEVER, BOTH SHALL BE REVIEWED MATERIALS AND INSTALLATION SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF GA-216"APPLICATION AND FINISHING OF SUBMIT DOCUMENT FROM FIRESTOP MANUFACTURER WHERIN MANUFACTURER RECOGNIZES AND APPROVES INSTALLER FOR SAID ACCEPTABLE TO GOVERNING AUTHORITIES. 11 $50 SW 67TH AVE. AND COORDINATED BY THE CONTRACTOR. REPORT ANY DISCREPANCIES WITHIN THE DOCUMENTS TO THE ARCHITECT. GYPSUM BOARD"BY THE GYPSUM ASSOCIATION,EXCEPT WHERE MORE DETAILED OR MORE STRINGENT REQUIREMENTS ARE MANUFACTURER'S FIRESTOP PRODUCTS. 2. PROVIDE LABELS PERMANENTLY FASTENED ON EACH FRAME THAT ARE WITHIN SIZE LIMITS ESTABLISHED BY NFPA AND SUITE 1 00 INDICATED, INCLUDING THE RECOMMENDATIONS OF THE MANUFACTURER. THE TESTING AUTHORITY. /� THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF REPRODUCIBLE AS-BUILT DOCUMENTS AT PROJECT CLOSEOUT. FIRESTOP MATERIAL SHALL BE DELIVERED IN THE MANUFACTURER'S ORIGINAL, UNOPENED CONTAINERS OR PACKAGES WITH THE A. PROVIDE 45 MINUTE LABELS. PORTLAND, WHERE WORK IS INDICATED FOR FIRE-RESISTANCE RATINGS, INCLUDING THOSE REQUIRED TO COMPLY WITH GOVERNING MANUFACTURER'S NAME, PRODUCT IDENTIFICATION, LOT NUMBER, UL LABEL,AND MIXING AND INSTALLATION INSTRUCTIONS AS B. PROVIDE LABELS FOR OPENINGS AS SCHEDULED ON THE DRAWINGS. O R VERIFY FIELD CONDITIONS AND EXISTING LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ANY AND REGULATIONS, PROVIDE MATERIALS AND INSTALLATIONS IDENTICAL WITH APPLICABLE ASSEMBLIES WHICH HAVE BEEN TESTED APPLICABLE. ALL OTHER APPLICABLE ITEMS THAT MAY AFFECT THE PROJECT. INSTALL NEW PLUMBING,SPRINKLER LINES AND HEADS, AND LISTED BY RECOGNIZED AUTHORITIES, INCLUDING UL , GYPSUM ASSOCIATION,A1A AND OTHER TESTING AND/OR AGENCIES 1.6 DELIVERY, STORAGE AND HANDLING 97223 MECHANICAL FANS, DUCTS SO AS TO NOT CONFLICT WITH LUMINAIRES AND ANY AND ALL FIELD CONDITIONS. THE CONTRACTOR IS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. MATERIALS SHALL BE STORED IN THE ORIGINAL,UNOPENED CONTAINERS OR PACKAGES,AND UNDER CONDTITIONS A. DELIVER FRAMES CARTONED TO PROVIDE PROTECTION DURING TRANSIT AND STORAGE AT PROJECT SITE. RESPONSIBLE FOR THE COORDINATION OF PLENUM ELEMENTS. ARRANGE OR MODIFY NON-VISIBLE ITEMS TO FIT CONDITIONS OR RECOMMENDED BY THE MANUFACTURER. B. INSPECT FRAMES UPON DELIVERY FOR DAMAGE. REFLECTED CEILING PLAN AS REQUIRED. ANY AND ALL COST RESULTING FROM CHANGES INCURRED TO ENSURE INTEGRITY OF THE ESTABLISH AND MAINTAIN ENVIRONMENTAL CONDITIONS FOR APPLICATION AND FINISHING GYPSUM BOARD TO COMPLY WITH ASTM 1. REPAIR MINOR DAMAGE TO POLYESTER FINISH BY USING AIR DRYING SPRAY ENAMEL OF MATCHING COLOR. REFLECTING CEILING PLAN LAYOUT SHALL BE BORN BY THE CONTRACTOR. C840 AND WITH GYPSUM BOARD MANUFACTURER'S RECOMMENDATIONS. EXAMINE THE AREAS AND CONDITIONS WHERE FIRESTOPS ARE TO BE INSTALLED AND NOTIFY THE ARCHITECT OF CONDITIONS 2.REPLACE FRAMES THAT CAN NOT BE SATISFACTORILY REPAIRED. THE CONTRACTOR SHALL COORDINATE ALL CONNECTIONS OF MECHANICAL, ELECTRICAL AND PLUMBING TO THE BASE BUILDING STEEL STUDS AND JOISTS SHALL COMPLY WITH ASTM C645,WITH FLANGE EDGES OF STUDS BENT BACK 90°AND DOUBLED OVER TO DETRIMENTAL HAVETO THE ECO PROPER AND TIMELY THE CONTRACTOR OFTHEWORK. ACCEPTABLEO NPROCEED WITH WORK UNTIL UNSATISFACTORY SYSTEMS WITH THE BUILDING MANAGEMENT. FORM 3/16"MINIMUM LIP(RETURN)AND COMPLYING WITH THE FOLLOWING REQUIREMENTS FOR MINIMUM THICKNESS OF BASE CONDITIONS BEEN CORRECTED BY IN A MANNER TO THE ARCHITECT. C. STORE FRAMES AT PROJECT SITE UNDER COVER AND AS NEAR AS POSSIBLE TO FINAL INSTALLATION LOCATION. DO NOT USE COVERING MATERIAL THAT WILL CAUSE DISCOLORATION OF ALUMINUM FINISH. THE CONTRACTOR SHALL PERFORM ALL WORK IN SUCH A MANNER THAT A SHUTDOWN OF ANY UTILITIES,ALARM, SECURITY OR (UNCOATED)METAL AND FOR DEPTH: INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S PRINTED INSTRUCTIONS FOR INSTALLATION AND,WHEN APPLICABLE THICKNESS: 22-GAUGE AT STUDS AND INTERIOR CEILING JOISTS, U.O.N. CURING, IN ACCORDANCE WITH TEMPERATURE AND HUMIDITY. CONFORM TO VENTILATION AND SAFETY REQUIREMENTS. 1.7 ENVIRONMENTAL REQUIREMENTS COMMUNICATIONS SYSTEMS SHALL NOT OCCUR WITHOUT THE CONSENT OF THE BUILDING MANAGEMENT. STUD DEPTH: 3 5/8", 16"Q.C., UNLESS OTHERWISE NOTED A. DO NOT BEGIN INSTALLATION OF ALUMINUM FRAMES UNTIL AREA OF WORK HAS BEEN COMPLETELY ENCLOSED AND FRAMING: ALL FRAMING MEMBERS SHALL BE GALVANIZED INSTALLATION OF FIRESTOPS SHALL BE PERFORMED BY AN APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY THE INTERIOR IS PROTECTED FROM THE ELEMENTS. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE ENGINEERING DRAWING REGARDING THE LOCATION OF MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION B. MAINTAIN TEMPERATURE AND HUMIDITY IN AREAS OF INSTALLATION WITHIN REASONABLE LIMITS,AS CLOSE AS POSSIBLE EXPOSED AND/OR FINISHED ENGINEERING DEVICES; SUCH AS LIGHT FIXTURES, HVAC DIFFUSERS AND GRILLES, ELECTRICAL FASTENERS SHALL BE PROVIDED OF TYPE,MATERIAL,SIZE,CORROSION RESISTANCE, HOLDING POWER,AND OTHER PROPERTIES PROCEDURES. TO FINAL OCCUPANCY STANDARDS. IF NECESSARY, PROVIDE ARTIFICIAL HEATING, COOLING AND VENTILATION TO MAINTAIN RECEPTACLES, ETC. HOWEVER, IN THE CASE OF DISCREPANCIES BETWEEN THE DRAWINGS,THE CONTRACTOR SHALL OBTAIN REQUIRED TO FASTEN STEEL FRAMING AND FURRING MEMBERS SECURELY TO SUBSTRATES INVOLVED. FASTENERS SHALL REQUIRED ENVIRONMENTAL CONDITIONS. CLARIFICATION FROM THE ARCHTECT PRIOR TO COMMENCING THE WORK. COMPLY WITH RECOMMENDATIONS OF GYPSUM DRYWALL MANUFACTURERS FOR APPLICATIONS INDICATED. CONTRACTOR SHALL COORDINATE FIRESTOPPING WORK AS REQUIRED WITH THE WORK OF OTHER TRADES. FIRESTOPPING SHALL GYPSUM BOARD SHALL BE PROVIDED IN ACCORDANCE WITH ASTM C36 OF TYPES INDICATED IN MAXIMUM LENGTHS AVAILABLE TO PRECEDE TYPSUM BOARD FINISHING. PART 2 PRODUCTS ADMINISTRATIVE NOTES AND SUBMITTALS MINIMIZE END-TO-END JOINTS. GYPSUM BOARD SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: THICKNESS: 5/8"THICK, UNLESS OTHERWISE NOTED WHERE FIRESTOPPING IS INSTALLED AT LOCATIONS WHICH REMAIN EXPOSED TO THE COMPLETED WORK, PROTECTION SHALL BE PROVIDED AS NECESSARY TO PREVENT DAMAGE TO ADJACENT SURFACES AND FINISHES,AND PROTECT AS NECESSARY AGAINST 2.1 MANUFACTURERS TYPE: REGULAR OR TYPE X FOR FIRE-RESISTANCE-RATED ASSEMBLIES DAMAGE FROM OTHER CONSTRUCTION ACTIVITIES. A. PROVIDE PRODUCTS MANUFACTURED BY FRAMEWORKS MANUFACTURING, INC. ; PROPOSAL REQUIESTS ISSUED BY THE ARCHITECT ARE FOR INFORMATION ONLY. DO NOT CONSIDER THEM INSTRUCTION EITHER TO EDGES: TAPERED B. 3727 YALE HOUSTON,TX 77018; (713)692-5222 (877)278-5222 FAX(713)692-1391. STOP WORK IN PROGRESS, OR TO EXECUTE THE PROPOSED CHANGE UNLESS SPECIFICALLY INSTRUCTED TO DO SO BY THEINSTALLATION OF FIRESTOPPING SYSTEMS SHALL BE PERFORMED BY A CONTRACTOR TRAINED OR APPROVED BY THE FIRESTOP INSTALL MOISTURE-RESISTANT GYPSUM WALL BOARD PANELS IN AREAS EXPOSED TO MOISTURE AS REQUIRED. MANUFACTURER. 2.2 MATERIALS ARCHTECT. A.ALUMINUM: CONTROLLED ALLOY BILLETS OF 6063 T5,TO ASSURE COMPLIANCE WITH TIGHT DIMENSIONAL TOLERANCES TRIM ACCESSORIES, INCLUDING CORNER BEADS, EDGE TRIM,AND CONTROL JOINTS SHALL COMPLY WITH ASTM C1047 AND BE LEAVE FINISHED WORK IN NEAT, CLEAN CONDITION,WITH NO EVIDENCE OF SPILLOVERS OR DAMAGE TO ADJACENT SURFACES. AND MAINTAIN COLOR UNIFORMITY. UPON THE OWNER'S APPROVAL OF A PROPOSAL REQUEST,THE CONTRACTOR WILL ISSUE A CHANGE ORDER FOR SIGNATURES OF PROVIDED AS NECESSARY. MUD, BLEND,AND SAND SMOOTH INTO ADJACENT SURFACES. THE OWNER AND ARCHITECT ON AIA FORM G701,AS PROVIDED IN THE CONDITIONS OF THE CONTRACT. WALLBOARD JOINT TREATMENT MATERIALS SHALL BE PROVIDED AND COMPLY WITH ASTM C475,ASTM C840,AND 2.3 EXTRUDED ALUMINUM FRAMES THE CONTRACTOR SHALL PREPARE A FULLY DEVELOPED,HORIZONTAL BAR-CHART TYPE CONSTRUCTION SCHEDULE. THE RECOMMENDATIONS OF MANUFACTURERS OF BOTH GYPSUM BOARD AND JOINT TREATMENT MATERIALS FOR THE APPLICATION HOLLOW M ETAL DOOR FRAMES A. FRAMEWORKS TYPE-2 FRAME SYSTEM: PROVIDE FRAMES WITH THE FOLLOWING CHARACTERISTICS: CONTRACTOR SHALL SUBMIT SUCH SCHEDULE WITHIN 7 CALENDAR DAYS OF'NOTICE TO PROCEED'. INDICATED: 1. RECTILINEAR DESIGN. THE CONTRACATOR SHALL PREPARE AND SUBMIT A COMPLETE SCHEDULE OF SUBMITTALS WITHIN 14 CALENDAR DAYS OF'NOTICE JOINT TAPE: PAPER REINFORCING TAPE PROVIDE AND INSTALL HOLLOW METAL COMPLYING WITH THE APPLICABLE REQUIREMENTS OF THE FOLLOWING PUBLICATIONS: 2. 1-1/2 INCH FACE PROFILES. DRYING-TYPE JOINT COMPOUNDS FACTORY-PREPACKAGED VINYL-ASED PRODUCTS AIA PAMPHLET NO. 80 3.SNAP ON TRIM: 1-1/4 INCH, 1-1/2"OR 2"WIDE. TO PROCEED'. ALL-PURPOSE COMPOUND FORMULATED FOR USE NBHA(NATIONAL BUILDERS HARDWARE ASSOCIATION) 4. OTHER TRIM OPTIONS AS SELECTED FROM MANUFACTURES CATALOGUE. THE CONTRACTOR SHALL REVIEW,AND APPROVE DATA SUBMITTALS,SHOP DRAWINGS AND SAMPLES PRIOR TO SUBMITTING THEM AS BOTH TAPING AND TOPPING COMPOUND NFPA STANDARD NO. 80 5. 0.070 INCH RABBET WALL THICKNESS. TO THE ARCHITECT. THE ARCHITECT SHALL NOT BE OBLIGATED TO REVIEW AND RETURN SUBMITTALS WITHOUT PROPERP.S. (PRODUCT STANDARD) N 6.THROAT SIZES 3-1/2", 3-3/4", 4-7/8" AUXILLIARY MATERIALS FOR GYPSUM DRYWALL CONSTRUCTION SHALL COMPLY WITH REFERENCED STANDARDS AND THE SDI(STEEL DOOR INSTITUTE}) NO. 100 AND 105 7.ADJUSTABLE THROAT FRAMES EXPANDABLE FROM 3-5/8"UP TO 7-1/4". CONTRACTOR REVIEW. RECOMMENDATIONS OF THE MANUFACTURER OF THE GYPSUM BOARD. UL STNNDARD FOR SAFETY NO.63 UTHE CONTRACTOR SHALL COORDINATE THE PREPARATION AND PROCESSING OF SUBMITTALS WITH THE PERFORMANCE OF THEN GUIDE ND120 I.D.O. A2. FABRICAINN PARTITIONS ARE DIMENSIONED FINISH FACE TO FINISH FACE UNLESS NOTED OTHERWISE. DIMENSIONS NOTED'CLEAR'(DLR)ARE NAAM STANDARD CHM-1 PRE-MACHINE JAMBS AND PREPARE FOR HARDWARE,WITH CONCEALED REINFORCEMENT PLATES, DRILLED AND TAPPED WORK SO THAT THE WORK WILL NOT BE DELAYED BY SUBMITTALS INCLUDING THE TIME REQUIRED FOR RESUBMITTALS. NOT ADJUSTABLE WITHOUT THE APPROVAL OF THE ARCHITECT. AS REQUIRED AND FASTENED WITHIN FRAME WITH CONCEALED SCREWS. THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ANY ERRORS,OMISSIONS OR DEVIATION FROM THEFIRE-RATED DOOR ASSEMBLY UNITS SHALL COMPLY WITH NEPA NO. 80. THEY SHALL BE IDENTICAL TO DOOR AND FRAME B. PROVIDE CORNER REINFORCEMENTS AND ALIGNMENT CLIPS FOR PRECISE BUTT OR MITERED CONNECTIONS. HEIGHTS ARE DIMENSIONED FROM THE TOP OF SLAB, UNLESS NOTED OTHERWISE. ASSEMBLIES WHOSE FIRE REISSTANCE CHARACTERISTICS HAVE BEEN DETERMINED PER ASTM E 152 AND WHICH ARE LABELED C. FABRICATE ALL COMPONENTS TO ALLOW SECURE INSTALLATION WITHOUT EXPOSED FASTENERS. REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE ARCHITECT'S REVIEW OF SHOP DRAWINGS, PRODUCT DATA OR SAMPLES. AND LISTED BY UL, FACTORY MUTUAL,WARNOCK HERSEY, OR OTHER TESTING AND INSPECTING ORGANIZATIONS ACCEPTABLE TO ALLOW 14 DAYS FOR INITIAL SUBMITTAL REVIEW. ALLOW 7 DAYS FOR REPROCESSING EACH SUBMITTAL. ALL PARTITIONS SHOWN ABUTTING INTO EXISTING WALLS SHALL ALIGN WITH FACE OF FINISHED SURFACES UNLESS NOTED AUTHORITIES HAVING JURISDICTION. 2.5 FINISHES OTHERWISE. A. FACTORY FINISH EXTRUDED FRAME COMPONENTS SO THAT ANY PART EXPOSED TO VIEW UPON COMPLETION OF D$' APS PROVIDE FIRE-RATED HOLLOW METAL FRAMES INVESTIGATED AND TESTED AS A FIRE DOOR ASSEMBLY, COMPLETE WITH TYPE OF INSTALLATION WILL BE UNIFORM IN FINISH AND COLOR. NO EXTENTION OF CONTRACT TIME WILL BE AUTHORIZED BECAUSE OF FAILURE TO TRANSMIT SUBMITTALS TO THE ARCHITECT SUBMIT MANUFACTURER'S PRODUCT SPECIFICATIONS FOR EACH TYPE OF GYPSUM BOARD, STEEL FRAME,AND TRIM ACCESSORY FIRE DOOR HARDWARE TO BE USED. IDENTIFY EACH FIRE DOOR FRAME WITH UL LABELS, INDICATING APPLICABLE FIRE RATING OF B. POLYESTER FINISH: COMPLY WITH AAMA 603.8; MULTIPLE-STAGE ELECTROSTATICALLY APPLIED THERMOSET POLYESTER 02 � SUFFICIENTLY IN ADVANCE OF THE WORK TO PERMIT PROCESSING. INDICATED. FRAME. FINISH, BAKED TO ASSURE HARDNESS. �OSLf'"A.REMLtriG SUBMITTALS SHALL BE TRANSMITTED FROM CONTRACTOR TO ARCHITECT USING A TRANSMITTAL FORM. ON THE TRANSMITTAL EXAMINE SUBSTRATE TO WHICH DRYWALL CONSTRUCTION ATTACHES OR ABUTS. PRESET HOLLOW METAL FRAMES, CAST-IN- ♦ 6526 ,. PROVIDE METAL FRAMES FOR DOORS OF TYPES AND STYLES AS SHOWN ON DRAWINGS AND SCHEDULES. CONCEAL FASTENINGS 1. COLOR: CUSTOM PAINT COLOR TO MATCH ARCHITECT SAMPLE RECORD RELEVANT INFORMATION AND REQUEST FOR DATA. ON THE FORM,OR SEPARATE SHEET, RECORD DEVIATIONS FROM ANCHORS,AND STRUCTURAL FRAMING SHALL BE IN COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES AND UNLESS OTHERWISE NOTED. FABRICATE FRAMES OF MINIMUM 18-GAUGE COLD-ROLLED STEEL. SAN FRANCISCO. CONTRACT DOCUMENT REQUIREMENTS, INCLUDING MINOR VARIATIONS AND LIMITATIONS. INCLUDE CONTRACTOR'S CERTIFICATION OTHER CONDITIONS AFFECTING PERFORMANCE OF DRYWALL CONSTRUCTION. DO NOT PROCEED WITH INSTALLATION UNTIL " CA THAT INFORMATION COMPLIES WITH CONTRACT REQUIREMENTS. ALL SHOP DRAWINGS MUST BE CROSS REFERENCED TO UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. FRAMES SHALL COMPLY WITH ASTM A366. FURNISH FRAMES WITH FIXED STIPS BUTTED. USE ROLLED SECTIONS FOR FIRE-RATED PART 3 EXECUTION ARCHITECTURAL DRAWINGS. OPENINGS. PROVIDE UL ANCHORS FOR FIRE-RATED OPENINGS, STRAP ANCHORS AT WOOD OR METAL STUDS,AND OTHER TYPES '(, j= SHOP DRAWINGS: SUBMIT ONE CORRECTABLE TRANSLUCENT REPRODUCIBLE PRINT AND ONE BLUELINE OR BLACKLINE PRINTS FOR STORE MATERIALS INSIDE UNDER COVER AND KEEP THEM DRY AND PROTECTED AGAINST DAMAGE FROM WEATHER, DIRECT AS INDICATED OR AS APPROVED FOR CONDITIONS OF USE. SUNLIGHT, SURFACE CONTAMINATION, CORROSION, CONTRUCTION TRAFFIC,AND OTHER CAUSES. GYPSUM BOARD SHALL BE 3.1 EXAMINATION THE ARCHITECT;'S AND ENGINEER'S REVIEW. SUBMITTALS WITHOUT A REPRODUCIBLE COPY WILL NOT BE ACCEPTED. STACKED NEATLY AND FLAT TO PREVENT SAGGING. FRAMES SHALL BE FABRICATED WITH WELDED MITERED CORNERS. A. EXAMINE PROJECT CONDITIONS AND VERIFY THAT THE WORK OF THIS SECTION MAY PROPERLY COMMENCE. DO NOT PRODUCT DATA: SUBMIT 3 COPIES OF EACH REQUIRED SUBMITTAL. SUBMIT 5 COPIES WHERE REQUIRED FOR MAINTENANCE PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. HANDLE GYPSUM BOARDS TO PREVENT DAMAGE TO EDGES, ENDS,AND SURFACES. DO NOT BEND OR OTHERWISE DAMAGE METAL PROVIDE HOLLOW METAL WORK AS MANUFACTURED BY ONE OF THE FOLLOWING: B.VERIFY WALL THICKNESS DOES NOT EXCEED STANDARD TOLERANCES ALLOWED BY SPECIFIED FRAME THROAT SIZES. MANUALS. THE ARCHITECT AND THE ENGINEER WILL EACH RETAIN ONE COPY,AND WILL RETURN THE OTHER MARKED WITH ACTON CORNER BEADS AND TRIM. TO BETAKEN AND CORRECTIONS OR MODIFICATIONS REQUIRED. ALLIED STEEL PRODUCTS OVERLY MFG.CO. AMERICAN STEEL PRODUCTS CORP. TEX-STEEL CORPORATION 3.2 INSTALLATION This drawing is the property of Associated E MINIMUM ROOM TEMPERATURE FOR NON-ADHESIVE ATTACHMENT OF GYPSUM BOARD SHALL NOT BE LESS THAN 40° F. MINIMUM AMERICAN WELDING AND MFG. CO. TRUSSBILT A. COMPLY WITH FRAME MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND APPROVED SHOP DRAWINGS. Space Design, Inc.and is not to be SAMPLES: SUBMIT 3 FULL SIZE, FULLY FABRICATED SAMPLES CURED AND FINISHED AS SPECIFIED AND PHYSICALLY IDENTICAL WITH ROOM TEMPERATURE FOR ADHESIVE ATTACHMENT AND FINISHING OR GYPSUM BOARD SHALL NOT BE LESS THAN 50° F FOR 48 GATEWAY METAL PRODUCTS STRICTLY ADHERE TO MAINTAINING SPECIFIED WALL THICKNESS TO INSURE DIMENSION DOES NOT EXCEED FRAME THROAT THE MATERIAL OR PRODUCT PROPOSED. SAMPLES INCLUDE PARTIAL SECTIONS OR MANUFACTURED OR FABRICATED COMPONENTS, HOURS PRIOR TO APPLICATION AND CONTINUOUS THEREAFTER UNTIL DRYING IS COMPLETE. reproduced or copied in whole or part.It is SIZE SPECIFIED. not to be used on anyother project and is to CUTS OR CONTAINERS OF MATERIALS, COLOR RANGE SETS,AND SWATCHES SHOWING COLOR,TEXTURE AND PATTERN. BUILDING SPACES SHALL BE VENTILLATED TO REMOVE WATER NOT REQUIRED FOR DRYING JOINT TREATMENT MATERIALS. AVOID SUBMIT DATA FOR EACH TYPE OF FRAME SPECIFIED, INCLUDING DETAILS OF CONSTRUCTION, MATERIALS, DIMENSIONS, B. INSTALL FRAMES PLUMB AND SQUARE, SECURELY ANCHORED TO SUBSTRATES WITH FASTENERS RECOMMENDED BY be returned upon request. Scales as stated SUBMIT 1 SAMPLE ONLY FOR THOSE SUBMITTALS ILLUSTRATING ASSEMBLY DETAILS,WORKMANSHIP, FABRICATION TECHNIQUES, DRAFTS DURING DRY, HOT WEATHER TO PREVENT MATERIALS FROM DRYING TOO RAPIDLY. HARDWARE PREPARATION,CORE, LABEL COMPLIANCE, SOUND RATINGS, PROFILES,AND FINISHES. C. INFRAME MANUFACTURER. C. NSTALL PARTITION COMPONENTS IN THE LONGEST POSSIBLE LENGTHS,WITH NO COMPONENT LESS THAT 4 FEET. FASTEN herein are for reference only as normal CONNECTIONS, OPERATION AND SIMILAR CHARACTERISTICS. reproduction processes may alter the SUBMIT MANUFACTURER'S CERTIFICATION FOR EACH CUSTOM STEEL FIRE-RATED DOOR FRAME WHICH IS LARGER THAN THE SIZE TO SUSPENDED CEILING GRID AT 48 INCHES ON CENTER MAXIMUM, USING#6 SHEET METAL SCREWS OR OTHER FASTENERS accuracy of original drawings. COORDINATE INSTALLATION OF CEILING SUSPENSION SYSTEM WITH INSTALLATION OF OVERHEAD STRUCTURAL SYSTEMS TO LIMITATIONS ESTABLISHED BY NFPA AND UL FOR LABELING. STATE THAT THE UNIT HAS BEEN CONSTRUCTED IN ACCORDANCE APPROVED BY FRAME MANUFACTURER. SAMPLES, SHOP DRAWINGS AND PRODUCT DATA REQUIRED TO BE SUBMITTED ARE LISTED ON THE SUBMITTAL SCHEDULE. ENSURE THAT INSERTS AND OTHER STRUCTURAL ANCHORAGE PROVISIONS HAVE BEEN INSTALLED TO RECEIVE CEILING ANCHORS WITH ALL THE APPLICABLEREQUIREMENTS FOR LABELED CONSTRUCTION. 1. USE CONCEALED INSTALLATION CLIPS TO ASSURE THAT SPLICES AND CONNECTIONS ARE TIGHTLY BUTTED AND Associated Space Design,Inc.2016 IN A MANNER THAT WILL DEVELOP THEIR FULL STRENGTH AND AT SPACING REQUIRED TO SUPPORT CEILING. PROPERLY ALIGNED. SHOP DRAWINGS SHALL SHOW COORDINATION WITH ASSOCIATED ADJACENT TRADES. FAILURE TO DO SO SHALL BE GROUNDS FOR SUBMIT SHOP DRAWINGS SHOWING FABRICATION AND INSTALLATION OF STANDARD METAL FRAMES. INCLUDE DETAILS OF EACH 2.SECURE CLIPS TO MAIN STRUCTURAL COMPONENTS AND NOT TO SNAP-IN OR TRIM MEMBERS. REJECTION OF THE SHOP DRAWINGS, VERIFY PARTITION THICKNESS FOR INTERNAL INCLUSIONS SUCH AS PLUMBING,TOILET ACCESSORIES, PANEL BOXES, ETC. NOTIFY FRAME TYPE, ELEVATIONS OF EACH DOOR DESIGN TYPES, CONDITIONS AT OPENINGS, DETAILS OF CONSTRUCTION, LOCATION, 3. DO NOT USE SCREWS OR OTHER FASTENERS THAT WILL BE EXPOSED TO VIEW WHEN INSTALLATION IS COMPLETE. THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN THE SCHEDULED PARTITION AND ANY INTERNAL INCLUSIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL FEES AND EXPENSES TO BE PAID TO ASD IN THE EVENT THAT MORE AND INSTALLATION REQUIREMENTS OF DOOR AND FRAME HARDWARE AND REFORCEMENTS,AND DETAILS OF JOINTS AND THAN 2 FINAL INSPECTIONS AND CORRESPONDING PUNCH LISTS ARE REQUIRED TO COMPLETE THE WORK. THE COST OF THE STEEL FRAMING INSTALLATION SHALL COMPLY WITH ASTM 0754 AND ASTM C840 REQUIREMENTS THAT APPLY TO FRAMING CONNECTIONS. SHOW ANCHORAGE AND ACCESSORY ITEMS. 3.3 ADJUSTING AND CLEANING ADDITIONAL FEES AND EXPENSES SHALL BE PAID BY THE CONTRACTOR AND SHALL BE DEDUCTED FROM THE CONTRACTOR'S PAY A. CLEAN EXPOSED FRAMES PROMPTLY AFTER INSTALLATION, USING CLEANING METHODS RECOMMENDED BY FRAME APPLICATION. FEES AND EXPENSES SHALL INCLUDE NORMAL HOURLY BILLING RATES, REPRODUCTION AND TRANSPORTATION INSTALLATION. SUBMIT SCHEDULE OF DOORS AND FRAMES USING SAME REFERENCE NUMBERS FOR DETAILS OPENINGS AS THOSE ON CONTRACT MANUFACTURER. COSTS. DRAWINGS. B.TOUCH UP MARRED AREAS SO THAT TOUCH-UP IS NOT VISIBLE FROM A DISTANCE OF 4 FEET. REMOVE AND REPLACE ALL PARTITIONS SHALL BE INSTALLED PLUMB,TAPED,AND SANDED SMOOTH SO THAT THERE ARE NO VISIBLE JOINTS. FRAMES THAT CAN NOT BE SATISFACTORILY ADJUSTED. FRAMES SHALL BE DELIVERED CARDBOARD-WRAPPED OR CRATED TO PROVIDE PROTECTION DURING TRANSIT AND JOB STORAGE. 3.4 PROTECTION Shop SUPPLEMENTARY FRAMING, BLOCKING,AND BRACING SHALL BE INSTALLED AT TERMINATIONS IN THE WORK AND FOR SUPPORT OF PROVIDE ADDITIONAL PROTECTION TO PREVENT DAMAGE TO FINISH OF FACTORY-FINISHED FRAMES. A. PROVIDE PROTECTION REQUIRED TO ASSURE THAT FRAMES WILL BE WITHOUT DAMAGE OR DETERIORATION UPON Submittals Drawings Samples Literature Other FIXTURES, EQUIPMENT SERVICES, HEAVY TRIM,GRAB BARS,TOILET ACCESSORIES, FURNISHINGS,AND SIMILAR CONSTRUCTION TO SUBSTANTIAL COMPLETION OF THE PROJECT. COMPLY WITH DETAILS INDICATED AND WITH RECOMMENDATIONS OF TYPSUM BOARD MANUFACTURER, OR IF NONE AVAILABLE, FRAMES SHALL BE INSPECTED UPON DELIVERY FOR DAMAGE. MINOR DAMAGES MAY BE REPAIRED PROVIDED REFINISHED ITEMS I MILLWORK X X I WITH "GYPSUM CONSTRUCTION HANDBOOK"PUBLISHED BY UNITED STATES GYPSUM CO. ARE EQUAL IN ALL RESPECTS TO NEW WORK AND ACCEPTABLE TO ARCHITECT. OTHERWISE, REMOVE AND REPLACE DAMAGED END OF SECTION DOORS AND FRAMES X X SCHEDULE ITEMS AS DIRECTED. I HARDWARE X X X SCHEDULE DO NOT BRIDGE BUILDING EXPANSION AND CONTROL JOINTS WITH STEEL FRAMING OR FURRING MEMBERS. BOTH SIDES OF JOINTS PAINT X 1 SHALL BE FRAMED OR FURRED INDEPENDENTLY AS INDICATED. FRAMES SHALL BE STORED AT BUILDING SITE UNDER COVER. PLACE UNITS ON MINIMUM FOUR INCH (4") HIGH WOOD BLOCKING. WALLCOVERING 1 X HANGERS SHALL BE SECURED TO STRUCTURAL SUPPORT BY CONNECTING DIRECTLY TO STRUCTURE WHERE POSSIBLE. AVOID USE OF NON-VENTED PLASTIC OR CANVAS SHELTERS WHICH COULD CREATE HUMIDITY CHAMBERS. IF CARDBOARD WRAPPERS ON FRAMES BECOME WET, REMOVE CARTON IMMEDIATELY. PROVIDE 1/4"SPACES BETWEEN STACKED FRAMES TO CEILING TILE X X OTHERWISE, HANGERS SHALL CONNECT TO CAST-IN-CONCRETE INSERTS OR OTHER ANCHORAGE DEVICES OR FASTENERS AS PROMOTE AIR CIRCULATION. WALL BASE X INDICATED. DO NOT ATTACH HANGERS TO METAL DECK TABS OR TO METAL ROOF DECK. FLOORING(CARPET,TILE, ETC.) X FABRICATE HOLLOW METAL UNITS TO BE RIGID, NEAT IN APPEARANCE,AND FREE FROM DEFECTS,WARP,OR BUCKLE. FABRIC WALL PANELS X X X I DO NOT CONNCECT OR SUSPEND STEEL FRAMING FROM DUCTS, PIPES, OR CONDUIT. HANGERS AND BRACES SHALL BE AT LEAST 2" ACCURATELY FORM METAL TO REQUIRED SIZES AND PROFILES. WHEREVER PRACTICAL, FIT AND ASSEMBLE UNITS IN THE 0 07.01.19 ISSUED FOR PERMIT MECHANICAL X CLEAR OF DUCTS, PIPES OR CONDUIT. MANUFACTURER'S PLANT. CLEARLY IDENTIFY WORK THAT CANNOT BE PERMANENTLY FACTORY-ASSEMBLED BEFORE SHIPMENT NO: DATE: REMARKS: ELECTRICAL X RUNNERS(TRACKS)SHALL BE INSTALLED AT FLOORS, CEILINGS,AND STRUCTURAL WALLS AND COLUMNS WHERE GYPSUM TO ASSURE PROPER ASSEMBLY AT PROJECT SITE. REVISIONS: LIGHTING X DRYWALL STUD SYSTEM ABUTS OTHER CONSTRUCTION. EXPOSED JOINTS SHALL BE WELDED CONTINUOUSLY; GRIND, DRESS,AND MAKE SMOOTH, FLUSH,AND INVISIBLE. METALIC FILLER DRAWING TITLE: POWER X TO CONCEAL MANUFACTURING DEFECTS IS NOT ACCEPTABLE. COVER PLATES X I EXTEND PARTITION FRAMING FULL HEIGHT TO STRUCTURAL SUPPORTS OR SUBSTRATES ABOVE SUSPENDED CEILINGS, EXCEPT SPECIFICATIONS SWITCHES X 1 WHERE PARTITIONS ARE INDICATED TO TERMINATE AT SUSPENDED CEILINGS. CONTINUE FRAMING OVER FRAMES FOR DOORS AND EXPOSED CONNECTIONS WITH HAIRLINE JOINTS SHALL BE ACCURATELY MACHINED, FILED,AND FITTED, UNLESS OTHERWISE OPENINGS AND FRAME AROUND DUCTS PENETRATING PARTITIONS ABOVE CEILING TO PROVIDE SUPPORT FOR GYPSUM BOARD. NOTED. OUTLETS X I Q GLAZING X X X AT DOORS AND SIMILAR OPENINGS, DO NOT CONTNUE DRYWALL JOINT ABOVE THE JAMB. OFFSET DRYWALL JOINT TO CENTER OF CONCEAL ALL FASTENINGS, UNLESS OTHERWISE NOTED. COUNTERSINK EXPOSED SCREWS USING FLAT PHILLIPS HEAD SCREWS. PROJECT NO.: ISSUE DATE: N- APPLIANCES X 1 OPENING WHERE POSSIBLE. d. --- FIRE EXTINGUISHER CABINETS X FRAMES SHALL BE PREPARED IN ACCORDANCE WITH FINAL DOOR HARDWARE SCHEDULE AND TEMPLATES PROVIDED BY 28021.00 07.0'{.19 ea PROJECTION SCREENS X ATTACH GYPSUM BOARD TO SUPPLEMENTARY FRAMING AND BLOCKING PROVIDED FOR ADDITIONAL SUPPORT AT OPENINGS AND HARDWARE SUPPLIER. INSTALLER SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF ANSI A115 SERIES SPECIFICATIONS FOR DRAWN BY: CHECKED BY: PLUMBING X X �Y 1 CUTOUTS. DOOR AND FRAME PREPARATION FOR HARDWARE. a)SPRINKLER SYSTEM X I COVER BOTH FACES OF STEEL STUD PARTITION FRAMING WITH GYPSUM BOARD IN CONCEALED SPACES(ABOVE CEILINGS, ETC.), SHEET NUMBER: p EXCEPT IN CHASE WALLS WHICH ARE BRACED INTERNALLY. EXCEPT WHERE CONCEALED APPLICATION IS INDICATED OR REQUIRED N MAY SOUND,BE LIMITED FIRE, TNOT LESS SMOKE AT75 OF FULL OVERAGE.BE ACCOMPLISHED WITH SCRAPS NOT LESS THAN 8 SQ. FT.AREA,AND AO. I I sku 1 I 1 WOOD FINISH HARDWARE (CONT.) RESILIENT FLOORING TILE PAINTING " QUALITY SHALL COMPLY WITH THE FOLLOWING STANDARDS: HINGE PINS SHALL BE PROVIDED AS FOLLOWS, UNLESS OTHERWISE INDICATED: KESILIEN I FLOOKINU I ILE INCLUDES VINYL COMPOST I ION i ILE, RESILIENT WALL BASE,VINYL TRANSITION STRIPS AND ANY OTHER PAIN i EXPOSED SURFACES WHETHER OR NOT COLORS ARE DESIGNATED IN SCHEDULES, EXCEPT WHERE A SURFACE OR MATERIAL • STEEL HINGES: STEEL PINS NON-FERROUS HINGES: STAINLESS RESILIENT FLOORING PRODUCTS AS REQUIRED TO PERFORM THE WORK. IS SPECIFICALLY INDICATED NOT TO BE PAINTED OR IS TO REMAIN NATURAL. WHERE AN ITEM OR SURFACE IS NOT SPECIFICALLY "INDUSTRY STANDARD (IS.) FOR WOOD FLUSH DOORS,"OF THE NATIONAL WOOD WINDOW AND DOOR ASSOCIATION(NWWDA) STEEL PINS OUT-SWING CORRIDOR DOORS: NON-REMOVEABLE MENTIONED, PAINT THE SAME AS SIMILAR ADJACENT MATERIALS OR SURFACES. IF OR FINISH IS NOT DESIGNATED, THE ARCHITECT PINS INTERIOR DOORS: NON-RISING PINS VINYL COMPOSITION TILE(VCT) SHALL BE FS SS-T-312,TYPE IV, 12"X 12"X 1/8" UNLESS INDICATED OTHERWISE. WILL SELECT FROM STANDARD COLORS AND FINISHES AVAILABLE. "ARCHITECTURAL WOODWORK QUALITY STANDARDS"AND SECTION 1300"ARCHITECTURAL FLUSH DOORS,"OF THE ARCHITECTURAL RESILIENT WALL BASE SHALL BE FS SS-W-40M TYPE I, IN ROLLS WITH MATCHING END STOPS AND PREFORMED OR MOLDED PAINTING INCLUDES FIELD PAINTING EXPOSED BARE AND COVERED PIPE AND DUCTS(INCLUDING COLOR CODING), HANGERS WOODWORK INSTITUTE(AWI)FOR GRADE OF DOOR,CORE CONSTRUCTION, FINISH AND OTHER REQUIREMENTS EXCEEDING THOSE HARDWAREMAAL OR AUTOMATIC FLUSH BOLT THECPRODUCT OF AND A MOUNTING RBR. ALL BOLTSSHALL FORBPROVIDED D DOORS LISTED IN CORNER UNITS, 1/8"GAGE, UNLESS INDICATED OTHERWISE. INSTALL STRAIGHT BAISE AT CARPET AND COVE BASE ELSEWHERE. EXPOSED STEET AND IRON WORK,AND PRIMED METAL SURFACES OF MECHANICAL AND ELECTRICAL EQUIPMENT. ASD OF THE NWMA STANDARD. SETS. THEY SHALL BE PRODUCT ONE MANUFACTURER. ALL FIRE-RATED SHALL HAVE UL WALL BASE HEIGHT SHALL BE 2 1!2". LABEL. PROVIDE MINIMUM 1/2"DIAMETER RODS OF BRASS, BRONZE, OR STAINLESS STEEL,WITH MINIMUM 3/4"THROW. PROVIDE DO NOT PAINT OVER UNDERWRITER'S LABORATORIES, FACTORY MUTUAL OR OTHER CODE REQUIRED LABELS OR EQUIPMENT DOORS SHALL COMPLY WITH REFERENCE AWI QUALITY STANDARD INCLUDEING SECTION 1500, "FACTORY FINISHING." WOOD DUSTPROOF STRIKE AT ALL LOCATIONS EXCEPT WHERE THRESHOLDS ARE SHOWN. VENEERED DOORS WITH TRANSPARENT FINISH SHALL BE PREFINISHED AT FACTORY. TRANSPARENT FINISH SHALL COMPLY WITH VINYL TRANSITION STRIPS SHALL BE JOHNSONITE VINYL MOLDINGS OR APPORVED EQUAL. NAME, IDENTIFIGATiON, PERFORMANCE RATING OR NOMENCLATURE PLATES. REQUIREMENTS INDICATED FOR GRADE, FINISH SYSTEM,STAINING EFFECT AND SHEEN: ALL FINISH HARDWARE TO BE INSTALLED ON OR IN METAL DOORS AND/OR FRAMES SHALL BE MANUFACTURED TO TEMPLATE. SUBMIT 12"X 12"SAMPLES OF EACH TYPE, COLOR AND FINISH OF EACH RESILIENT TILE REQUIRED AND OF ALL ACCESSORIES. SUBMIT PRODUCT DATA FOR EACH PAINT SYSTEM SPECIFIED, INCLUDING BLOCK FILLERS AND PRIMERS. PRODUCT DATA SHALL AWI GRADE: PREMIUM TEMPLATE MACHINE SCREWS SHALL BE FURNISHED FOR ALL SUCH MATERIALS. THIS SUPPLIER SHALL FURNISH HARDWARE INCLUDE THE MANUFACTURER'S TECHNICAL INFORMATION AND CERTIFICATION BY THE MANUFACTURER THAT PRODUCTS SUPPLIED STAIN: MATCH ARCHITECT'S SAMPLE SCHEDULE AS APPROVED BY THE ARCHITECT AND ALL NECESSARY TEMPLATE TRANSMITTALS TO METAL FRAME FABRICATORS OR EFFECT: FILLED FINISH OTHER SUPPLIERS REQUIRING SAME, FOR THEIR COORDINATION AND USE. UPON REQUEST, CHECK SHOP DRAWINGS OF SUCH INSPECT SUBFLOOR SURFACES TO DETERMINE SATISFACTORY CONDITIONS IN COMPLIANCE WITH THE MANUFACTURER'S COMPLY WITH ALL REGULATIONS CONTROLLING USE OF VOLATILE ORGANIC COMPOUNDS(VOC'S). SHEEN: 40% OR AS DETERMINED BY APPROVED SAMPLE. OTHER WORK TO CONFIRM THAT ADEQUATE PROVISIONS ARE MADE FOR PROPER LOCATION AND INSTALLATION OF HARDWARE. INSTRUCTIONS. ENSURE THAT THE SUBFLOOR IS FREE FROM CRACKS, HOLES, RIDGES AND COATINGS AND RESIDUES PREVENTING ADHESIVE BOND AND OTHER DEFECTS IMPAIRING PERFORMANCE OR APPEARANCE. SUBMIT SAMPLES TO INCLUDE BUT NOT LIMITED TO: ALL WOOD DOORS SHALL BE MANUFACTURED TWO INCHES(2") LONGER THAN SHOWN ON DRAWINGS AND/OR SCHEDULES. BOTTOM SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA FOR EACH ITEM OF HARDWARE. INCLUDE WHATEVER INFORMATION MAY BE REPAIR MINOR HOLES, CRACKS, DEPRESSIONS AND ROUGH AREAS, USING LEVELING AND PATCHING COMPOUNDS AS PAINTED WOOD: PROVIDE TWO 12"SQUARE SAMPLE OF EACH COLOR AND MATERIAL ON IT'S SCHEDULED SUBSTRATA. OF DOOR ONLY WILL BE TRIMMED TO EACH OPENING FOR REQUIRED CLEARANCE. NECESSARY TO SHOW COMPLIANCE WITH REQUIREMENTS AND INCLUDE INSTRUCTIONS FOR INSTALLATION AND FOR MAINTENANCE RECOMMENDED BY THE VCT MANUFACTURER. IDENTIFY EACH FINISH AND SCHEDULED LOCATION. OF OPERATING PARTS AND FINISHES. FIRE-RATED DOORS SHALL BE INSTALLED IN CORRESPONDING FIRE-RATED FRAMES IN ACCORDANCE WITH REQUIREMENTS OF NFPA NO. 80. PROVIDE UL LABEL ON EACH FIRE-RATED DOOR. SUBMIT FINAL HARDWARE SCHEDULE IN MANNER INDICATED BELOW. COORDINATE HARD-WARE WITH DOORS, FRAMES,AND REMOVE COATINGS ON SUBFLOOR SURFACES THAT WOULD PREVENT ADHESIVE BOND, INCLUDING CURING COMPOUNDS STAINED OR NATURAL WOOD: PROVIDE TWO 12"SQUARE SAMPLES OF THE SPECIFIED FINISH ON THE ACTUAL VENEERS RELATED WORK TO ENSURE PROPER SIZE,THICKNESS, HAND, FUNCTION,AND FINISH OF HARDWARE. ORGANIZE HARDWARE INCOMPATIBLE WITH VCT FLOORING ADHESIVES, PAINT, OILS.WAXES AND SEALERS. AND SOLID STOCK WOOD SPECIES NOTED. IDENTIFY EACH FINISH AND SCHEDULED LOCATION. FIRE RATED WOOD DOORS SHALL BE IDENTICAL IN MATERIALS AND CONSTRUCTION TO UNITS TESTED IN DOOR AND FRAME SCHEDULE INTO "HARDWARE SETS"INDICATING COMPLETE DESIGNATIONS OF EVERY ITEM REQUIRED FOR EACH DOOR OR INSTALL RESILIENT FLOORING IN STRICT COMPLIANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. EXAMINE SUBSTRATES AND CONDITIONS UNDER WHICH PAINTING WILL BE PERFORMED FOR COMPLIANCE WITH MANUFACTURER'S ASSEMBLIES PER ASTM E152 AND WHICH ARE LABELED AND LISTED FOR RATINGS INDICATED BY UL,WARNOCK HERSEY OR OTHER OPENING. INCLUDE THE FOLLOWING INFORMATION: REQUIREMENTS FOR APPLICATION OF PAINT. DO NOT BEGIN PAINT APPLICATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN 920 SW 6th Avenue TESTING AND INSPECTION AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. TYPE, STYLE, FUNCTION, SiZE,AND FINISH OF EACH HARDWARE ITEM EXTEND RESILIENT FLOORING INTO TOE SPACES, DOOR REVEALS AND INTO CLOSETS, AND SIMILAR OPENINGS. SCRIBE, CUT AND CORRECTED. NAME AND MANUFACTURER F EACH ITEM FIT VCT TO PERMANENT FIXTURES, BUILT-IN FURNITURE AND CABINETS, PIPES, RECEPTACLES AND PERMANENT COLUMNS, WALLS 12th Floor PROVIDEORSPRODUCTS FACES:F ONE OF THE FOLLOWING MANUFACTURES, SUBJECT TO COMPLIANCE WITH REQUIREMENTS FOR SOLID CORE FASTENINGS OF ANO OTHER PERTINENT INFORMATION AND PARTITIONS. RUN TILE UNDER NON-PERMANENT COLUMNS AND POWER POLES PRIOR TO THEIR INSTALLATION. PROVIDE THE MANUFACTURER'S BEST COMMERCIAL GRADE QUALITY PAINT MATERIAL ON THE VARIOUS COATING TYPES SPECIFIED. DOORS WITH VENEER LOCATION HARDWARE SET CROSS-REFERENCED WITH DRAWINGS AND SCHEDULE Portland, OR ALGOMA HARDWOODS, INC. EXPLANATION OF ALL ABBREVIATIONS, SYMBOLS, CODES, ETC CONTAINED ON SCHEDULE PAINT MATERIAL CONTAINERS NOT DISPLAYING THE MANUFACTURE'S PRODUCT IDENTIFICATION WILL NOT BE ACCEPTABLE. BUELL DOOR COMPANY MOUNTING LOCATIONS FOR HARDWARE LAY TILE FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS, DISCOUNTING MINOR OFFSETS, SO THAT TILES AT OPPOSITE T 678,491 .3773 EGGERS INDUSTRIES,ARCHITECTURAL DOOR DIVISION KEYING INFORMATION ENDS OF ROOM ARE OF EQUAL WIDTH. ADJUST AS NECESSARY TO AVOID USE OF CUT WIDTHS LESS 1/2 TiLE AT ROOM PROVIDE COMPATIBLE PRIMERS AND UNDERCOAT PAINT AS SPECIFIED BY THE MANUFACTURER OF THE FINISH COATS. IPIK DOOR COMPANY, INC. DOOR AND FRAME SIZES AND MATERIALS. PERIMETERS. LAY TILE SQUARE TO ROOM AXIS UNLESS SHOWN OTHERWISE. . www.asdsky.com WEYERHAUSER COMPANY APPLY PAINT ACCORDING TO MANUFACTURER'S INSTRUCTIONS. USE APPLICATORS AND TECHNIQUES BEST SUITED FOR KEYING SYSTEM SHALL BE REVIEWED WITH OWNER AND BASE BUILDING OWNER,AND PROVIDE THE TYPE REQUIRED(MASTER, MATCH TILES FOR COLOR AND PATTERN BY USING TILE FROM CARTONS IN SAME SEQUENCE AS MANUFACTURED AND PACKAGED, SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. SEE PAINT SPECIFICATIONS FOR FINISH REQUIREMENTS FOR OPAQUE AND TRANSPARENT FINISHES. GRANDMASTER, OR GREAT-GRANDMASTER), EITHER NEW OR INTEGRATED WITH BASE BUILDING OWNER'S EXISTING SYSTEM. IF SO NUMBERED. CUT TILE NEATLY AROUND ALL FIXTURES. BROKEN, CRACKED, CHIPPED, DAMAGED OR DEFORMED TiLES ARE NOT ACCEPTABLE. PAINT ALL EXPOSED SURFACES WHETHER OR NOT COLORS ARE DESIGNATED IN"SCHEDULES,"EXCEPT WHERE A SURFACE OR FACES AND EDGES OF DOORS SHALL BE SHOP-SEALED FOR TRANSPARENT FINISH WITH STAiN AND OTHER REQUIRED PRE- HARDWARE UNiTS SHALL BE MOUNTED AT HEIGHTS INDICATED IN"RECOMMENDED LOCATIONS FOR BUILDERS HARDWARE FOR MATERIAL IS SPECIFICALLY INDICATED NOT TO BE PAINTED OR IS TO REMAIN NATURAL. WHERE AN ITEM OR SURFACE IS NOT TREATMENTS AND FIRST COAT OF FINISH. STANDARD STEEL DOORS AND FRAMES"BY THE DOOR AND HARDWARE INSTITUTE, EXCEPT AS SPECIFICALLY INDICATED OR AS LAY TILE WITH GRAIN RUNNING IN ONE DIRECTION. SPECIFICALLY MENTIONED, PAINT THAT SURFACE TO MATCH SIMILAR ADJACENT MATERIALS OR SURFACES. REQUIRED TO COMPLY WITH GOVERNING REGULATIONS AND EXCEPT AS MAY BE DIRECTED BY ARCHITECT ON DRAWINGS UNDER INSTALL ALL RESILIENT FLOORING PRODUCTS WITH WATERPROOF, STABILIZED, LOW V.O.C.TYPE ADHESIVES. PAINT ANY REUSED HVAC DIFFUSERS AND RETURN AIR GRILLES TO MATCH ADJACENT CEILING GRID, UNLESS NOTED OTHERWISE. SUBMIT DOOR MANUFACTURE'S TECHNICAL DATA FOR EACH TYPE OF DOOR, INCLUDING DETAILS OF CORE AND EDGE CONSTRUCTION THE DOOR DETAILS AND TYPICAL MOUNTING HEIGHT DETAIL. CONTRACTORANY VERIFY IN FIELD. AND FACTORY FINISHING SPECIFICATIONS. ADHERE RESILIENT FLOORING TO SUBSTRATES USING FULL SPREAD OF ADHESIVE APPLIED IN COMPLIANCE WITH FLOORING EACH HARDWARE ITEM SHALL BE INSTALLED IN COMPLIANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND NOT T PAINT MANUFACTURER'S PRINTED INSTRUCTIONS. OVER DIRT, RUST SCALE,GREASE,MOISTURE, SCUFFED SURFACES, OR CONDITIONS DETRIMENTAL TO FORMATION SUBMIT SHOP DRAWINGS INDICATING LOCATION AND SIZE OF EACH DOOR, ELEVATION OF EACH TYPE OF DOOR, DETAILS OF RECOMMENDATIONS. WHEREVER CUTTING AND FITTING IS REQUIRED TO INSTALL HARDWARE ONTO OR INTO SURFACES WHICH DOF A DURABLE PAINT FILM. CONSTRUCTION, LOCATION AND EXTENT OF HARDWARE BLOCKING, FIRE RATINGS, REQUIREMENTS FOR FACTORY FINISHING,AND ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER WAY, COORDINATE REMOVAL, STORAGE AND REINSTALLATION OR IMMEDIATELY UPON COMPLETION OF RESILIENT FLOORING INSTALLATION, SWEEP OR VACUUM FLOOR THOROUGHLY. REMOVE ANY OTHER PERTINENT DATA. APPLICATION OF SURFACE PROTECTIONS WITH FINISHING WORK SPECIFIED IN PAINTING SPECIFICATIONS. SURFACE-MOUNTED EXCESS ADHESIVE OR OTHER BLEMISHES USING CLEANER RECOMMENDED BY TILE MANUFACTURER. APPLY ADDITIONAL COATS IF UNDERCOATS, STAINS, OR OTHER CONDITIONS SHOW THROUGH FiNAL COAT OF PAINT UNTIL PAINT ITEMS SHALL NOT BE INSTALLED UNTIL FINISHES HAVE BEEN COMPLETED ON THE SUBSTRATE. FILM IS OF UNIFORM FiNISH, COLOR AND APPEARANCE. SUBMIT WRITTEN WARRANTY AGREEMENT IN DOOR MANUFACTURER'S STANDARD FORM,SIGNED BY MANUFACTURER, INSTALLER, THE CONTRACTOR SHALL WAX AND POLISH ALL RESILIENT FLOORING ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS, AND CONTRACTOR,AGREEING TO REPAIR OR REPLACE DEFECTIVE DOORS THAT HAVE WARPED(BOW, CUP OR TWIST)OR THAT SET UNITS LEVEL, PLUMB,AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHEMNT SUBSTRATE AS UNLESS NOTED OTHERWISE. ENSURE EDGES, CORNERS, CREVICES,WELDS,AND EXPOSED FASTENERS RECEIVE A DRY FILM • SHOW PHOTOGRAPHING OF CORE CONSTRUCTION BELOW FACE, DO NOT CONFORM TO TOLERANCE LIMITATIONS OF NWWDA OR NECESSARY FOR PROPER INSTALLATION AND OPERATION. THICKNESSTHAT SURFACES, EQUIVALENT INCLUDING THAT SPECIFIED. DELAMINATE. THE WARRANTY SHALL BE IN EFFECT FOR LIFETIME OF INSTALLATION AND SAHLL COMMENCE UPON SUBSTANTIAL PROTECT FLOORING AGAINST DAMAGE DURING CONTRUCTION TO COMPLY WITH RESILIENT TILE MANUFACTURER'S INSTRUCTIONS. COMPLETION. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION AND FUNCTION OF APPLY WATER BASED PAINTS ONLY WHEN THE TEMPERATURE OF THE SURFACES TO BE PAINTED AND SURROUNDING AIR EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE PROTECT FLOORING AGAINST DAMAGE FROM ROLLING LOADS FOR INITIAL PERIOD FOLLOWING INSTALLATION BY COVERING WITH TEMPERATURES ARE BETWEEN 50° F AND 90°F. APPLY SOLVENT THINNED PAINTS ONLY WHEN THE TEMPERATURE OF SURFACES OFFSET TOLERANCE AT MEETING EDGE OF PAIR OF DOORS SHALL NOT EXCEED 1/8"EVEN IF SINGLE DOORS COMPLY WITH WARP APPLICATION MADE. TOLERANCE. PLYWOOD OR HARDBOARD. USE DOLLIES TO MOVE STATIONARY EQUIPMENT OR FURNISHINGS ACROSS FLOORS. TO BE PAINTED AND SURROUNDING AIR TEMPERATURES ARE BETWEEN 45° F AND 95°F. WARRANTY SHALL INCLUDE REINSTALLATION WHICH MAY BE REQUIRED DUE TO REPAIR OR REPLACEMENT OF DEFECTIVE DOORS REFLECTED CEILING NOTES APPLY PROTECTIVE FLOOR POLISH TO RESILIENT TILE FLOORING SURFACES FREE FROM SOIL, EXCESS ADHESIVE, OR SURFACE PROVIDE PRODUCTS FROM ONE OF THE FOLLOWING MANUFACTURERS: T H E WHERE DEFECT WAS NOT APPARENT PRIOR TO HANGING. BLEMISHES. USE COMMERCIALLY AVAILABLE PRODUCT ACCEPTABLE TO RESILIENT TILE MANUFACTURER. POLISH RESILIENT INS I ALL FULLY RECESSED CEILING FIX I UKES, INCLUDING, 13U I NU I LIMI I ED TO HVAC SUPPLY DIFFUSERS, RETURN AIR GRILLES. FLOORING IMMEDIATELY PRiOR TO SUBSTANTIAL COMPLETION. DEVOE AND REYNOLDS CO. WOOD DOORS SHALL BE PROTECTED DURING TRANSIT, STORAGE,AND HANDLING TO PREVENT DAMAGE, SOILING,AND ETC. UNLESS NOTED OTHERWISE. DURON PAINT PARTNERS DETERIORATION. COMPLY WITH THE"ON-SITE CARE"RECOMMENDATIONS OF NWWDA PAMPHLET, "CARE AND FINISHING OF WOOD BENJAMIN MOORE AND CO. L-- DOORS,"AND WITH MANUFACTURER'S INSTRUCTIONS. SHOULD LIGHT FIXTURES SPECIFIED NOT BE AVAILABLE TO MEET THE PROJECT SCHEDULE,THE CONTRACTOR SHALL NOTIFY THE THE SHERWIN WILLIAMS CO. GROUP ARCHITECT IMMEDIATELY AND SHALL SUBMIT AN EQUAL ALTERNATE THAT CAN MEET THE PROJECT SCHEDULE TO THE ARCHITECT WOOD DOORS SHALL BE CARTONED AND/OR CRATED TO PROVIDE PROTECTION DURING TRANSIT AND JOB STORAGE. COMPLY WITH FOR APPROVAL. FOR ALL GYPSUM WALL BOARD SURFACES,APPLY ONE COAT OF PRIMER AND TWO COATS OF ACRYLIC LATEX FOR FLAT SHEEN MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR FIRE-RATED DOORS TO PREVENT MOISTURE DETERIORATION WALLS, UNLESS NOTED OTHERWISE. APPLY ONE COAT OF PRIMER AND TWO COATS OF LATEX ENAMEL FOR SEMI-GLOSS OR OF FIRE-RETARDANT SALTS. INSTALL SPRINKLER HEADS TO BE CENTERED ON THE ACOUSTIC CEILING TILES WITH TRIM RINGS INSTALLED TIGHT TO CEILING EGGSHELL SHEEN WALLS, UNLESS NOTED OTHERWISE. TILE. THE SPRINKLER PERMIT BASED ON FIELD CONDITTOR SHALL IONS.IONS. ALL SPRINKLER WORK SHALLE WHAT EVER DRAWING L CONFORMTONFPA DOCUMENTS3 AND NFA 114,REQUIRED BY CODE FOR C E RAM I C TILE OPAQUE FINISHES FOR WOOD DOORS SHALL BE ONE COAT OF FACTORY APPLIED PRIMER AND TWO COATS OF SEMI-GLOSS LATEX DOORS AND PANELS SHALL BE CREELS IN ACCORDANCE WITH TOLERANCE REQUIREMENTS OF NWWDA INSUSTRY STANDARD I.S. 1. ENAMEL, UNLESS NOTED OTHERWISE. 11850 SW 67TH AVE. PROVIDE STANDARD BEVEL OR RADIUS TO EDGES OF DOORS AS REQUIRED BY THE INSTALLATION. THE CONTRACTOR SHALL REWORK THE EXISTING CEILING AS NECESSARY WHERE AFFECTED BY NEW CONSTRUCTION OR SUITE 100 IDENTIFY EACH DOOR WITH INDIVIDUAL OPENING NUMBERS WHICH CORRELATE WITH DESIGNATION SYSTEM USED ON SHOP DEMOLITION. WHERE NEW ACOUSTICAL CEILING SYSTSTEM IS TO BE INSTALLED,ALIGN NEW WORK WITH THE EXISTING AND INSTALL CERAMIC TILE IN STRICT COMPLIANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS,THE'HANDBOOK FOR CERAMIC DRAWINGS FOR DOORS, FRAMES,AND HARDWARE, USING TEMPORARY, REMOVABLE OR CONCEALED MARKEINGS. MATCH THE EXISTING CEILING SYSTEM TYPE AND COLOR. TILE INSTALLATION', MOST RECENT EDITION, PUBLISHED BY THE TILE COUNCIL OF AMERICA AND ANSI A137.1,AS APPLICABLE FOR THE SAL LC OV E R I N G PORTLAND, OR REMOVE AND REPLACE CEILING TILES AS REQUIRED TO PERFORM SPECIFIED MECHANICAL, ELECTRICAL, PLUMBING AND FIRE TYPES,COMPOSITIONS AND GRADES SPECIFIED. THE MOST STRINGENT REQUIREMENTS SHALL APPLY. DO NOT DELIVER OR INSTALL DOORS UNTIL CONDITIONS FOR TEMPERATURE AND RELATIVE HUMIDITY HAVE BEEN STABILIZED AND VINYL WALL COVERING SHALL COMPLY WITH FS CCC-W-408A FOR THE TYPE AND CLASS REQUIRED AND AS SCHEDULED. PROVIDE 97223 WILL BE MAINTAINED IN STORAGE AND INSTALLATION AREAS DURING THE REMAINDER OF CONSTRUCTION PERIOD TO COMPLY WITH PROTECTION WORK. REPLACE ANY DAMAGED, SOILED OR MISSING TILES TO MATCH THE EXISTING IN TYPE, STYLE AND COLOR. SUBMIT MANUFACTURER'S PRODUCT DATA AND THREE FULL SIZE SAMPLES OF EACH TYPE SPECIFIED. CLASS 2 MILDEW-RESISTANT OSNABURG OR DRILL BACKING. COMPLY WITH ASTM D 1308 FOR DETERMINING STAIN RESISTANCE. THE AWI QUALITY STANDARD SECTION 100-S-3"MOISTURE CONTENT,"APPLICABLE TO THE PROJECT'S GEOGRAPHICAL LOCATION. CONDITION DOORS TO AVERAGE PREVAILING HUMIDITY IN INSTALLATION AREA PRIOR TO HANGING. WHEN SPECIFIED,CERAMIC MOSAICS SHALL BE STANDARD GRADE. WALL COVERINGS SHALL BE CLASS A WITH A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPMENT OF 450 OR LESS AS PER ACOUSTICAL TILE CEILINGS ASTM E 84. CONTRACTOR SHALL EXAMINE ALL INSTALLED DOOR FRAMES PRIOR TO HANGING DOOR.VERIFY THAT FRAMES COMPLY WITH MORTAR SHALL COMPLY WITHANSI A118.4. INDICATED REQUIREMENTS FOR THE SIZE,TYPE, LOCATION,AND SWING CHARACTERISTICS AND HAVE BEEN INSTALLED WITH PLUMB PROVIDE MANUFACTURER'S STANDARD UNITS OF CONFIGURATION INDICATED THAT COMPLY WITH ASTM E1264 CLASSIFICATIONS VINYL WALL COVERING SHALL NOT BE INSTALLED EXTERIOR BUILDING WALLS. NOTIFY THE ARCHITECT IN THE CASE OF CONFLICTS JAMBS AND LEVEL HEADS. REJECT DOORS WITH DEFECTS. AS DESIGNATED BY REFERENCE TO TYPES, PATTERNS,ACOUSTICAL RATINGS,AND LIGHT REFLECTANCES, UNLESS OTHERWISE GROUT SHALLCONFORM TO ANSI 118.6 AND SHALL BE AMERICAN OLEAN SANDED FLOOR GROUT. COLORS SHALL BE SUBMITTED FOR WITHIN THE CONTRACT DOCUMENTS. NOTED. ARCHITECT'S SELECTION. COORDINATE MEASUREMENTS OF HARDWARE MORTISES IN METAL FRAMES TO VERIFY DIMENSIONS AND ALIGNMENT BEFORE INSTALL MANUFACTURER'S RECOMMENDED ADHESIVE, PRIMER AND SEALER, MANUFACTURED EXPRESSLY FOR USE WITH THE PROCEEDING WITH FACTORY PREMACHINING. SUSPENSION SYSTEM ATTACHMENT DEVICES SHALL BE FIXED FOR FIVE(5)TIMES DESIGN LOAD INDICATED IN ASTM C635,TABLE I, ENSURE THAT SUSBSTRATES AND AREAS WHERE TILE WILL BE INSTALLED COMPLY WITH THE MANUFACTURER'S REQUIREMENTS SELECTED WALL COVERING. PROVIDE MATERIALS WHICH ARE MILDEW AND ALKALI REISTANT,STRIPPABLE AND NON-STAINING TO DIRECT HUNG, UNLESS OTHERWISE NOTED. FOR PREPARATION AND THAT SUBSTRATES ARE FIRM, DRY, CLEAN AND FREE FROM OIL OR WAXY FILMS AND CURING COMPOUNDS. THE WALL COVERING. INSTALLATION OF WOOD DOORS SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS,WITH REFERENCED INDUSTRY STANDARDS, - AND AS INDICATED ON CONTRACT DRAWINGS. THE MOST STRINGENT REQUIREMENTS SHALL APPLY. WIRE FOR HANGERS AND TIES SHALL MEET ASTM A641, CLASS(, ZINC COATING, SOFT TEMPER. DELIVER ALL PRODUCTS TO THE JOB SITE IN UNOPENED CONTAINERS. SUBMIT MANUFACTURER'S PRODUCT DATA FOR EACH TYPE OF PRODUCT SPECIFIED. INCLUDE DATA ON PHYSICAL CHARACTERISiCS, FIRE AND SMOKE RATED CHARACTERISTICS, DURABILITY, AND FADE RESISTANCE. PROVIDE SHOP DRAWINGS DOORS SHALL BE ALIGNED AND FIT IN FRAMES WITH UNIFORM CLEARANCES AND BEVELS AS INDICATED. DO NOT TRIM STILES AND PROVIDE WIRE SIZED SO THAT STRESS AT THREE(3)TIMES HANGER DESIGN LOAD(ASTM C635,TABLE I, DIRECT HUNG)SHALL BE BE FURNISH SIZE AND COLOR OR TRIM TO MATCH FIELD TILE. USE COVER BASE AT FLOOR, BULLNOSE CAP AT TOP OF BASE. SHOWING LOCATION AND EXTENT OF EACH WALL COVERING AND TERMINATION POINTS. RAILS IN EXCESS OF LIMITS SET BY MANUFACTURER OR PERMITTED WITH FIRE-RATED DOORS. SEAL CUT SURFACES AFTER FITTING LESS THAN YiELD STRESS OF WIRE, BUT PROVIDE NOT LESS THAN 0.106"DIAMETER(12 GAUGE). AND MACHINING. VARIATIONS IN FLOOR SURFACE SHALL BE NO GREATER THATN 1/8" IN 10'-0", NONCUMULATIVE. REPORT ALL UNACCEPTABLE FLOOR PROVIDE SAMPLE OF EACH WALL COVERING SPECIFIED. THE SAMPLES SHALL BE LARGE ENOUGH TO SHOW THE FULL PATTERN ACOUSTICAL CEILINGS SHALL BE INSTALLED TO COMPLY WITH THE FOLLOWING STANDARDS: SURFACES TO THE ARCHITECT. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN REPEAT. SMALL PATTERN SAMPLES SHALL BE 8 1/2"X 11"MINIMUM SIZE. REHANG OR REPLACE DOORS WHICH DO NOT SWING OR OPERATE FREELY AND REFINISH OR REPLACE ALL DOORS DAMAGED DURING CISCA"CEILING SYSTEMS HANDBOOK" CORRECTED. INSTALLATION. ASTM C636"STANDARD FOR INSTALLATION OF CEILING SUSPENSION SYSTEMS" SUBMIT MANUFACTURER'S INSTRUCTION ON MAINTENANCE, CLEANING PRODUCTS AND METHODS TO BE USED ON EACH WALL ASTM C636 AND E580 AS APPLICABLE TO ACOUSTICAL SNAP-1N METAL PAN CEILINGS. LAY TILE SO AS TO MINIMIZE CUTS LESS THAN 1/2 TILE IN SIZE. LOCATE TILE CUTS IN FLOORS SO AS TO BE LEAST CONSPICUOUS. COVERING USED. REPLACE OR REFINISH DOORS WHERE CONTRACTOR'S WORK CONTRIBUTED TO REJECTION OR TO VOIDING OF MANUFACTURER'S ALIGN ALL FLOOR JOINTS TO GIVE STRAIGHT, UNIFORM GROUT LINES. GROUT JOINTS TO BE 1/8" WARRANTY. WHERE ACOUSTICAL PANEL CEILINGS ARE REQUIRED TO COMPLY WITH A FIRE HAZARD CLASSIFICATION FOR FLAMESPREAD, FUEL CLIMATIZE WALL COVERINGS BY REMOVING THEM FROM THE PACKAGING IN THE INSTALLATION AREA NOT LESS THAN 24 HOURS INSTALLER SHALL ADVISE THE CONTRACTOR OF PROPER PROCEDURES REQUIRED FOR PROTECTION OF INSTALLED WOOD DOORS CONTRIBUTION,AND SMOKE DEVELOPMENT, PROVIDE PANELS WHICH HAVE BEEN TESTED, RATED,AND LABELED BY UL FOR THE SMOOTH ALL EXPOSED CUT EDGES. CLEAN ALL TILE OF GROUT FILM AND RESIDUE UPON COMPLETION. PRIOR TO INSTALLATION. REQUIRED RATINGS AS LISTED IN THE"CLASSIFIED BUILDING MATERIALS INDEX"BY UL. FROM DAMAGE OR DETERIORATION UNTIL TIME OF SUBSTANTIAL PROJECT COMPLETION. PROHIBIT ALL FOOT TRAFFIC ON TILE FLOOR FOR AT LEAST 3 DAYS AND PREFERABLY 7 DAYS. FOLLOW MANUFACTURER'S PRINTED INSTRUCTIONS FOR SURFACE PREPARATION. PRIME NEW GYPSUM BOARD WITH A PROVIDE MANUFACTURER'S STANDARD UNITS FOR CONFIGURATION INDICATED WHICH ARE PREPARED FOR MOUNTING METHOD RECOMMENDED PRIMER. ALLOW NEW PLASTER TO CURE AND TREAT AREAS OF HIGH ALKALINITY. DESIGNATED AND WHICH COMPLY WITH FS SS-S-118 REQUIREMENTS, INCLUDING THOSE INDICATED BY REFERENCE TO TYPE, FINISH HARDWARE FORM, PATTERN, GRADE, LIGHT REFLECTANCE COEFFICIENT, EDGE DETAIL,AND JOINT DETAIL. COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS FOR INSTALLATION OF WALL COVERINGS,ACCESSORIES AND RELATED CARPET PRODUCTS. FINISH HARDWARE SHALL BE PROVIDED FOR ALL DOORS INCLUDING ALL ITEMS KNOWN COMMERCIALLY AS BUILDERS HARDWARE OR OBTAINUNITS FORFEACH ONE CONTINUOUS,NUVISUALLYURER, CYRE L T ONE PROCESS,. ONOTAND CHANGEOF UNIFORM STOF MATERIALS AND COLOR FOR EACH TYPERSINSTALL WALL COVERINGS WITH NO GAPS, OVERLAPS OR FRAYING SEAMS. PLACE WALL COVERINGS CONTINUOUSLY OVER FINISH HARDWARE. INCLUDE LOCK CYLINDERS FOR LOCKS FURNISHED IN OTHER SECTIONS WHERE SO SPECIFIED. REQUIRED,HRORELATED AREA. DO BRANDS OF DURING THE COURSE OF OUTSIDE AND INSIDE CORNERS. INSTALL SEAMS VERTICAL AND PLUMB AT NO LESS THAN 6 INCHES FROM OUTSIDE CORNERS AND 3 THE WORK WITHOUT APPROVAL. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE SCHEDULING, RECEIVING, INSPECTION AND INSTALLATION OF THE GOODS INCHES FROM INSIDE CORNERS. NO HORIZONTAL SEAMS. REMOVE AiR BUBBLES, WRINKLES AND OTHER DEFECTS. TRIM EDGES ALL FINISH HARDWARE SHALL COMPLY WITH FLORIDA ACCESSIBILITY AND ADA CODES.ALL LOCKS AND LATCHES SHALL BE LEVER NECESSARY COMPONENTS FOR A COMPLETE SUSPENSION SYSTEM SHALL BE SUPPLIED, INCLUDING BUT NOT LIMITED TO INSERTS, AND MATERIALS TO BE USED IN THIS WORK. CARPET GOODS SHALL BE DELIVERED TO THE JOB SITE IN THE MANUFACTURER'S ROLLS FOR PATTERN MATCH AND TIGHT CLOSURE AT SEAMS AND EDGES. TYPE. PROVIDE LOCKS WITH KNURLED LEVERS ON ENTRY SIDE TO DOORS WHICH ARE POTENTIALLY DANGEROUS TO BLIND OR ANCHORS, HANGERS, CARRYING CHANNELS, MAIN RUNNERS, CROSS RUNNERS, SPLINES, EDGE MOLDINGS, SPLICES, CLIPS, OR PACKAGES AND SHALL BE CLEARLY MARKED AS TO SIZE, DYE LOT AND MATERIAL. VISUALLY HANDICAPPED PERSONS. FASTENERS,TIRE WIRES, HOLD-DOWN DEVICES,AND ACCESSORIES AND DEVICES AS APPLICABLE. REMOVE EXCESS ADHESIVE AT FINISHED SEAMS, EDGES AND ADJACENT SURFACES. HARDWARE FOR FIRE-RATED OPENINGS SHALL COMPLY WITH NFPA NO. 80 AND LOCAL BUILDING CODE REQUIREMENTS. PROVIDE THE CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY ALL DIMENSIONS AND OTHER CONDITIONS AS REQUIRED TO ACCURATELY ALL WALL COVERING SHALL TERMINATE AT AN APPROPRIATE REVEAL, BREAK OR INSIDE CORNER. ONLY HARDWARE WHiCH HAS BEEN TESTED AND LISTED BY UL OR FM FOR TYPES AND SIZES OF DOORS REQUIRED AND COMPLIES PROVIDE MANUFACTURER'S STANDARD UNITS OF METAL, FINISH,AND SHAPES RECOMMENDED FOR THE APPLICATIONS INDICATED, LAY OUT AND FIT ALL ITEMS SPECIFIED. UNLESS OTHERWISE NOTED. WITH REQUIREMENTS OF DOOR AND DOOR FRAME LABELS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING ANY DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE NO NAMES, DESIGNS,OR LABELS SHALL BE PERMITTED ON THE FOLLOWING ITEMS: FACE OF CYLINDERS,TURNPIECES OR PROVIDE EXPOSED SINGLE-FLANGE MOLDINGS FOR SUPPORT AT EDGES OF CEILING,AT WALLS, PENETRATIONS, ETC. SHOWN ON THE DRAWINGS. ANY DIFFERENCE FOUND SHALL BE SUBMITTED TO THE ARCHITECT FOR CONSIDERATION PRIOR TO PROCEEDING WiTH THE WORK. MILLWORK OPERATING TRIM OF LOCK SETS OR LATCH SETS,CASE COVERS OF SURFACE APPLIED CLOSING DEVICES,AND UNDERSIDE OF DOOR HOLDER ARMS. PROVIDE SUSPENSION MANUFACTURER'S SPECIAL EDGE-TRIM MOLDING OF TYPES INDICATED FOR INTERRUPTIONS IN CEILING WHERE EDGES OF TILE WOULD OTHERWISE BE EXPOSED. CIRCULAR PENETRATIONS TO CEILING SHALL HAVE EDGE MOLDINGS THE CONTRACTOR SHALL BE TOTALLY RESPONSIBLE FOR THE ACCURACY OF HIS MEASUREMENTS ON TOTAL YARDAGE COMPLY WITH PROVISIONS OF THE ARCHITECTURAL WOODWORK INSTITUTE(AWI) ARCA... - WHERE SEVERAL MANUFACTURERS ARE SPECIFIED FOR ONE TYPE OF HARDWARE, USE ONLY THE PRODUCTS OF ONE FABRICATED TO DIAMETER REQUIRED TO FIT PENETRATION EXACTLY. REQUIREMENTS TO BE FURNISHED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SECURITY OF ALL GOODS STORED ON THE EXCEPT AS OTHERWISE SHOWN OR SPECIFIED, �,�g C MANUFACTURER. JOB SITE. "QUALITY STANDARDS, MOST RECENT EDITION. WORK SHAL BE PERFORMED IN THE HIGHEST GRADE APPLICABLE. SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING MANUFACTURERS: lUSFpH A.R1±ML►NG .� ARMSTRONG WORLD INDUSTRIES, INC. BEFORE ORDERING ANY MATERIALS OR FABRICATING ANY WORK,THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND SPECIFIC ITEMS AWI STANDARD THE DRAWINGS SHOW THE SWING OR TRAVEL OF EACH DOOR LEAR(LEFT, RIGHT, REVERSE BEVEL, SLIDE, ETC.). FURNISH EACH ITEM CHICAGO METALLIC CORPORATIONW OF HARDWARE FOR PROPER INSTALLATION AND OPERATION OF THE DOOR TRAVEL AS SHOWN. CONDITIONS AT THE SITE FOR ALL WORK WHICH MUST BE ACCURATELY FITTED TO OTHER CONSTRUCTION, INCLUDING WALL-TO-WALL, � � 9526 ...j NATIONAL ROLLING MILLS, INC. OFFSET, DOOR AND OTHER DIMENSIONS CONTROLLED BY OTHER TRADES AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF STANDING AND RUNNING TRIM WITH OPAQUE FINISH 300 �, USG INTERIORS, INC. THE SAME. CASEWORK W/TRANSPARENT FiNISH 400&400A SAN F Ft/INCISCO.,} ACCEPTABLE MANUFACTURERS: �► HINGES, BUTTS, PIVOTS: STANLEY, McKINNEY, HAGER, LAWRENCE CELOTEX PLASTIC LAMINATE CLAD CABINETS 400&400B COMPLY WITH CARPET MANUFACTURER'S INSTALLATION RECOMMENDATIONS TO PREPARE SUBSTRATES INDICATED TO RECEIVE ARCHITECTURAL COUNTERTOPS 400&400C LOCK/LEVER SETS: SCHLAGE SUBMIT MANUFACTURER'S PRODUCT SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR EACH ACOUSTICAL CEILING CARPET INSTALLATION. LEVEL SUBFLOOR TO WITHIN 1/4" IN 10 FEET, NONCUMULATIVE, IN ALL DIRECTIONS. SAND OR GRIND SMOOTH LUMBER 100 E'(j�;O'� • CLOSER: CORBIN/RUSSWIN DC2200/DC2100, LCN 4040 MATERIAL REQUIRED AND FOR EACH SUSPENSION SYSTEM, INCLUDING CERTIFIED LABORATORY TEST REPORTS AND OTHER DATA PROTRUSIONS, BUMPS AND RIDGES. PATCH AND REPAIR CRACKS AND ROUGH AREAS. FILL DEPRESSIONS. USE LEVELING AND PANELING 500 DOOR TRIM: QUALITY, ROCKWOOD, HAGER AS REQUIRED TO SHOW COMPLIANCE WITH THESE SPECIFiCATIONS. INCLUDE MANUFACTURER'S RECOMMENDATION FOR PATCHING COMPOUNDS TO FiLL CRACKS AND DEPRESSIONS IN SUBFLOOR AS RECOMMENDED BY THE CARPET MANUFACTURER. SHELVING 600, CUSTOM GRADE DOOR STOPS: GLYNN-JOHNSON, IVES, MODRICK, QUALITY, ROCKWOOD CLEANING AND REFINISHING ACOUSTICAL UNITS, INCLUDING PRECAUTIONS AGAINST MATERIALS AND METHODS WHICH MAY BE MISCELLANEOUS WORK 700 DOOR HOLDERS: GLYNN-JOHNSON, CHECKMATE,ABH, IVES, ROCKWOOD DETRIMENTAL TO FINISHES AND ACOUSTICAL PERFORMANCE. ALL CARPET OF THE SAME SPECIFICATION SHALL COME FROM THE SAME DYE LOT AND MUST MEET INDUSTRY STANDARDS FOR SIDE TO ARCHITECTURAL FLUSH DOORS 1300 THRESHOLDS AND WEATHERSTRIP: PEMKO, REUSE, ZERO, NATIONAL GUARD SIDE MATCH. THE CONTRACTOR SHALL USE LOW V.O.C.ADHESIVE AS RECOMMENDED BY THE MANUFACTURER. STILE AND RAiL DOORS 1400 STRIKE: IVES SUBMIT SAMPLES FOR VERIFICATION PURPOSES OF EACH TYPE OF EXPOSED FINISH REQUIRED, PREPARED ON SAMPLES OF SIZE, FACTORY FINISHING 1500 WHERE SEVERAL MANUFACTURERS ARE SPECIFIED FOR ONE TYPE OF HARDWARE, USE ONLY THE PRODUCTS OF ONE THICKNESS,AND MATERIAL INDICATED FOR FINAL UNiT OF WORK. SUBMIT THE MANUFACTURER'S INSTALLATION MANUAL, MAINTENANCE GUIDE AND STANDARD WARRANTY FOR ALL SPECIFIED INSTALLATION OF ARCHITECTURAL WOODWORK 1700 This drawing is the property of Associated MANUFACTURER. CARPETS. Space Design, Inc.and is not to be SUBMIT FULL-SIZE SAMPLES OF EACH TILE TYPE, PATTERN,AND COLOR REQUIRED. CABINET CONSTRUCTION STYLE SHALL BE'FLUSH OVERLAY'AS PER AWI STANDARDS. reproduced or copied in whole or part. It is SUBMIT THREE 24"X 24"SAMPLES OF ALL ORDERED DYE LOTS FOR SPECIFIED CARPETS. not to be used on any other project and is to FASTENINGS FOR INSTALLATION SHALL BE FURNISHED WITH EACH HARDWARE ITEM. PROVIDE PHILLIPS FALT-HEAD COUNDERSUNK COORDINATE LAYOUT AND INSTALLATION OF ACOUSTICAL CEILING UNITS AND SUSPENSION SYSTEM COMPONENTS WITH OTHER ALL VENEERS SHALL BE AWI PREMIUM GRADE. ALL TRANSPARENT AND SEMI-TRANSPARENT MILLWORK SHALL BE AWI PREMIUM be returned upon request.Scales as stated SCREWS UNLESS OTHERWISE NOTED. ANY EXPOSED(EXPOSED UNDER ANY CONDITION)SCREWS SHALL MATCH HARDWARE FINISH CONSTRUCTION THAT PENETRATES CEILINGS OR IS SUPPORTED BY THEM, INCLUDING LIGHT FIXTURES, HVAC EQUIPMENT, FIRE- SUBMIT SEAMING LAYOUT SHOP DRAWINGS FOR REVIEW AND APPROVAL BY THE ARCHITECT PRIOR TO INSTALLATION. DIRECTION OF GRADE. ALL PLASTIC LAMINATE WORK SHALL BE AWI CUSTOM GRADE. HOWEVER, PLASTIC LAMINATE EDGE BANDING SHALL BE OR, IF EXPOSED IN SURFACES OF OTHER WORK,SHALL MATCH FINISH OF SUCH OTHER WORK AS CLOSELY AS POSSIBLE. PROVIDE SUPPRESSION SYSTEM COMPONENTS,AND PARTITION SYSTEM. herein are for reference only as normal SEX NUTS AND BLOTS FOR ALL DOOR CLOSERS, EXIT DEVICES, AND DOOR HOLDERS ON METAL DOORS AND FIRE-RATED WOOD SEAMING AND VARIOUS COLOR AND PATTERN LOCATIONS SHALL BE SHOWN ON THE SHOP DRAWINGS. APPLIED PRIOR TO FACE LAMINATE. THIS REQUIREMENT SUPERSEDES AWI STANDARDS. reproduction processes may alter the DOORS. DELIVER ACOUSTICAL CEILING UNTIS TO PROJECT SITE IN ORIGINAL UNOPENED PACKAGES AND STORE THEM IN A FULLY CARPET SHALL BE INSTALLED BY THE 'DIRECT GLUE DOWN' METHOD USING THE MANUFACTURER'S MOST STRINGENT VENEERS SHALL BE LAID UP AS CENTER MATCHED AND BOOK MATCHED. SEMI-TRANSPARENT AND TRANSPARENT FINISHES SHALL accuracy of original drawings. ENCLOSED SPACE WHERE THEY WILL BE PROTECTED AGAINST DAMAGE FROM MOISTURE, DIRECT SUNLIGHT, SURFACE RECOMMENDATIONS AND REQUIREMENTS. INSTALL STABILIZED, LOW V.O.C. TYPE ADHESIVE. BE AWI#2, CATALYZED LACQUER, UNLESS NOTED OTHERWISE. SHEEN LEVEL SHALL BE MEDIUM RUBBED EFFECT,40 DEGREES. Associated Space Design, Inc. 2016 r CONCEALED FASTENERS SHALL BE PROVIDED FOR HARDWARE UNITS WHICH ARE EXPOSED WHEN DOOR IS CLOSED, EXCEPT TO THE CONTAMINATION,OR OTHER CAUSES. STAIN COLOR TO MATCH THE ARCHITECT'S SAMPLE. ALL STAIN GRADE WOOD SHALL BE SANDED USING 150 GRIT GARNET OPEN EXTENT NO STANDARD UNITS OF THE TYPE SPECIFIED ARE AVAILABLE WITH CONCEALED FASTENERS. DO NOT USE THRU-BOLTS FOR INSTALLATION SHALL BE PERFORMED BY SKILLED MECHANICS IN ACCORDANCE WITH CR1 STANDARD 104,"STANDARD PRACTICE FOR COAT. THIS REQUIREMENT SUPERSEDES AWi STANDARDS. INSTALLATION WHERE BOLT HEAD OR NUT ON OPPOSITE FACE IS EXPOSED IN OTHER WORK, EXCEPT WHERE IT IS NOT FEASIBLE TO EXAMINE SUBSTRATES AND STRUCTURAL FRAMING TO WHICH CEILING SYSTEM ATTACHES OR ABUTS,WITH INSTALLER PRESENT, INSTALLATION OF TEXTILE FLOOR COVERING MATERIALS"BY THE CARPET AND RUG INSTITUTE AND WITH THE MAUFACTURER'S ADEQUATELY REINFORCE THE WORK. IN SUCH CASES, SLEEVES SHALL BE PROVIDED FOR EACH THRU-BOLT OR USE SEX SCREW FOR COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THIS AND OTHER SECTIONS THAT AFFECT INSTALLATION AND ANCHORAGE RECOMMENDATIONS AND INSTRUCTIONS. THE MOST STRINGENT REQUIREMENTS SHALL APPLY. INSTALLATION SHALL BE WITH THE PROVIDE 3 FINISHED SAMPLES OF EACH TYPE OF TRIM AND WOOD VENEER TO BE USED ON THE PROJECT. FASTENERS. OF CEILING SYSTEM. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. HIGHEST DEGREE OF WORKMANSHIP. INSTALLATION CRAFTSMEN SHALL BE REQUIRED TO SHOW EVIDENCE OF AT LEAST THREE ALL CLOSERS SHALL BE FULLY ADJUSTABLE TYPE WITH COMPLETE SPRING POWER ADJUST-HENT, FIELD ADJUSTABLE ACCORDING TO YEARS EXPERIENCE IN CARPET INSTALLATION WORK OF A SIMILAR QUALITY. INSTALL STANDING AND RUNNING TRIM WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING FULL LENGTH PIECES. COPE AT DOOR SIZE AND FREQUENCY OF USE. ALLOW FULL 180°OPENING OF DOORS UNLESS RESTRICTED BY WALLS. FURNISH FLUSH MOUNT DO NOT!INSTALL INTERIOR ACOUSTICAL CEILINGS UNTIL SPACE IS ENCLOSED AND WEATHERPROOF,WET WORK IN SPACE IS RETURNS AND MITER AT CORNERS. COMPLETED AND NOMINALLY DRY,WORK ABOVE CEILINGS IS COMPLETE,AND AMBIENT CONDITIONS OF TEMPERATURE AND EXTEND CARPET UNDER OPEN-BOTTOMED AND RAISED-BOTTOMED OBSTRUCTIONS AND UNDER REMOVABLE FLANGES OF TRANSOM BRACKEST WHERE NO TRANSOM BAR EXISTS. WHERE CLOSERS ARE INDICATED TO BE DELAYED ACTION, PROVIDE UNITS HUMIDITY WiLL BE CONTINUOUSLY MAINTAINED AT VALUES NEAR THOSE INDICATED FOR FINAL OCCUPANCY. OBSTRUCTIONS. EXTEND CARPET INTO CLOSETS AND ALCOVES OF ROOMS INDICATED TO BE CARPETED, UNLESS ANOTHER FLOOR PROVIDE SHOP DRAWINGS SHOWING THE LOCATION OF EACH ITEM, DIMENSIONED PLANS, ELEVATIONS, SECTIONS, LARGE SCALE DESIGNED WITH AN ADJUSTABLE DELAY THAT HOLDS THE DOOR OPEN BEFORE THE CLOSING CYCLE BEGINS. FINISH IS INDICATED FOR SUCH SPACES. EXTEND CARPET UNDER ALL MOVABLE FURNITURE AND EQUIPMENT, UNLESS NOTED DETAILS,ATTACHMENT DEVICES AND ALL OTHER COMPONENTS. ON DOORS MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL UNITS TO BALANCE BORDER WIDTHS AT OPPOSITE EDGES OTHERWISE. ALL CLOSERSACCESSIBLE TO THE PHYSICALLY HANDICAPPED SHALL COMPLY WITH STATE AND FEDERAL(ADA)STANDARDS FOR DOOR OPENINGACFORCE AND DELAYED ACTION CLOSING. OF EACH CEILING. AVOiD THE USE OF LESS-THAN-HALF WIDTH UNITS AT BORDERS AND COMPLY WITH REFLECTED CEILING PLANS CHECK ACTUAL DIMENSIONS OF OTHER CONSTRUCTION WHERE MILLWORK MUST FIT BY ACCURATE FIELD MEASUREMENTS PRIOR WHEREVER POSSIBLE. SEAMS SHALL BE PRESSED BY HAND AND/OR SUITABLE TOOL TO PRODUCE THE BEST POSSIBLE EVEN TOP PILE WIDTH-TO-WIDTH. TO FABRiCAION OF THE WORK. CLOSERS SHALL BE SIZED ON JOBSITE BY INSTALLATION CREW. SIZE IS TO BE IN STRICT ACCORDANCE WITH ADA,ANSI A117.1,AND ADJACENT WIDTHS OF CARPET MUST BE INSTALLED TO FINISH AT EXACTLY THE SAME ELEVATION,OR THE WORK WILL BE REJECTED MANUFACTURERINSTRUCTIONS. DIRECTIONALLY-PATTERNED ACOUSTICAL UNITS SHALL BE ARRANGED AND ORIENTED IN THE SAME DIRECTION. AND REPLACED AT NO ADDITIONAL COST TO THE OWNER. TO THE GREATEST DEGREE POSSIBLE, FINISH ARCHITECURAL WOODWORK AT THE FACTORY OR MILLWORK SHOP. DEFER ONLY' FINAL TOUCH UP, CLEANING AND POLISHING UNTIL AFTER INSTALLATION. WHETHER SPECIFIED IN HARDWARE SETS OR NOT,ALL FIRE-RATED DOORS SHALL RECEIVE A CLOSER. MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND SHALL COMPLY WITH ALL CARPET WIDTHS SHALL BE INSTALLED WITH ALL ROWS OF PILE RUNNING IN THE SAME DIRECTION, UNLESS SHOWN OTHERWISE ON GOVERNING REGULATIONS, FIRE RESISTANCE RATING REQUIREMENTS AS INDICATED,AND INDUSTRY STANDARDS APPLICABLE TO THE APPROVED SHOP DRAWINGS. INSTALL MILLWORK PLUMB, LEVEL AND STRAIGHT. SHIM AS REQUIRED WITH CONCEALED SHIMS PROVIDE A MAXIMUM TOLERANCE PROVIDE PARALLEL ARMS FOR ALL OVERHEAD CLOSERS, UNLESS OTHERWISE NOTED. THE WORK. OF 1/8"IN 8'-O"FOR PLUM AND LEVEL. SCRIBE AND CUT MILLWORK TO FIT ADJOINING WORK AND REFINISH CUT SURFACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FLASH PATCHING AND TO HAVE THE FLOOR IN CONDITION TO RECEIVE THE EXCEPT FiRE-RATED DOORS, EXIT DEVICES SHALL BE EQUIPED WITH KEYED DOGGING DEVICE TO HOLD THE PUSH BAR DOWN AND THE INSTALL SUSPENSION SYSTEM TO COMPLY WITH ASTM C636,WiTH HANGERS SUPPORTED ONLY FROM BUILDING STRUCTURAL SCHEUDLED FLOORING. ADJUST HARDWARE TO CENTER DOORS AND DRAWERS iN OPENINGS AND TO PROVIDE UNENCOMBERED OPERATION. LATCHBOLT IN A RETRACTED POSITION.WHEN FUNCTION OF EXIT DEVICE REQUIRES CYLINDER, PROVIDE TYPE OF CYLINDER(RIM OR MEMBERS AS INDICATED. 0 07.01.19 ISSUED FOR PERMIT MORTISE) REQUIRED AND KEYED AS PER INSTRUCTIONS. LEVER DESIGN SHALL MATCH LOCKS. ALL COUNTERTOPS SHALL BE 1 1/2"THICK ALONG THE FRONT FACE. HANGERS SHALL BE LOCATED NEAR EACH END(WITHIN 12")AND SPACED 4'-0"ALONG EACH CARRYING CHANNEL OR DIRECT-HUNG NO: DATE: REMARKS: WHERE EXIT DEVICES ARE REQUIRED ON FIRE-RATED LABEL DOORS, DEVICES SHALL BE PROVIDED WITH UL LABEL INDICATING"FIRE RUNNERS, UNLESS OTHERWISE NOTED. JOINTS FOR STONE TOPS SHALL BE BUTT JOINTS WITH MINIMAL SEALANT EXPOSED. REVISIONS: EXIT HARDWARE." FOR DOORS WITHOUT FIRE RATING, PROVIDE DEVICES LISTED FOR"PANIC HARDWARE." WHETHER SPECIFIED IN HANGER WIRES SHALL BE INSTALLED AT RECESSED LIGHT FIXTURES RESTING ON SAME CEILING COMPONENT OR SUPPORTED BY CABINET HARDWARE: DRAWING TITLE: HARDWARE SETS OR NOT,ALL FIRE EXIT DEVICES SHALL CARRY A UL FIRE RATED LABEL AT FIRE DOORS AND BE IN COMPLIANCE WITH CROSS TEES ON MORE THAN TWO (2) SIDES. SECURE WIRE HANGERS BY LOOPING AND WiRE-TIEING EITHER DIRECTLY TO NFPA STANDARD NO. 80. STRUCTURES OR TO INSERTS, EYE-SCREWS OR OTHER DEVICES WHICH ARE SECURE AND APPROPRIATE FOR THE SUBSTRATE AND A. HARDWARE TO COMPLY WITH ANSI A156.9, 'AMERICAN NATIONAL STANDARD FOR CABINET HARDWARE.' SPECIFICATIONS MATCHING FINISHES SHALL BE PROVIDED FOR HARDWARE UNITS AT EACH DOOR OR OPENING TO THE GREATEST EXTENT POSSIBLE. WHICH WILL NOT DETERIORATE OR FAIL WITH AGE OR ELEVATED TEMPERATURE. B. HINGES SHALL BE PROPER NUMBER PER LEAF AS NOTED iN MANUFACTURER'S LOAD CHARTS, BUT NOT LESS THAN 3 PER LEAF. PROVIDE FULL OR HALF OVERLAY AS REQUIRED. PROVIDE SPRING LOADED HINGES FOR EASE OF DOOR EDGE TRIM MOLDINGS SHALL BE INSTALLED WHERE INDICATED,AND ELSEWHERE AS NEEDED,TO CONCEAL EDGES OF ACOUSTICAL OPERATION. BASIS OF DESIGN SHALL BE BLUM MODEL 90, 170 DEGREE OPENING CONCEALED HINGES. Q REDUCE DIFFERENCES IN COLOR AND AS MUCH AS COMMERCIALLY POSSIBLE WHERE THE TEXTURES OF BASE METAL OR METAL FORMING PROCESS IS DEFERENT FOR INDIVIDUAL UNITS OF HARDWARE EXPOSED AT THE SAME DOOR OR OPENING. IN GENERAL, MATCH ITEMS TO THE MANUFACTURER'S STANDARD FINISH FOR THE LATCH AND LOCKSET(OR PUSH-PULL UNITS) FOR COLOR AND UMTS WHICH WOULD OTHERWISE BE EXPOSED TO VIEW AFTER COMPLETION OF THE WORK. ANCHOR WITH FASTENER OR SECURE C. DRAWER GLIDES SHALL BE K&VOR EQUAL BY GRANT OR ACCURIOE OF CORRECT SIZE FOR DRAWER DEPTH. PROJECT NO.: ISSUE DATE: dam' TEXTURE. REDUCE VARIANCE IN HUE IN THE COLOR OF EACH FINISH. TYPE OF FINISH FOR EACH HARDWARE IS INDICATED IN THE IN PLACE WITH PERMANENT ADHESIVE. PROVIDE SIDE PAIR 100 LB. RATED BALL BEARING ROLLERS 1/2 WIDE UNITS W/FULL EXTENSION. 28021.00 07.01.19 0 HARDWARE SCHEDULE. D. SILENCERS SHALL BE 1/2"DIAMETER RUBBER. INSTALL ACOUSTICAL TILE IN ACCORDANCE WiTH SUSPENSION SYSTEM. DRAWN BY: CHECKED BY: PROVIDE NUMBER OF HINGES INDICATED, BUT NOT LESS THAN THREE(3)HINGES PER DOOR LEAF FOR DOORS 90"OR LESS IN HEIGHT CLEAN EXPOSED SURFACES OF ACOUSTICAL CEILINGS, INCLUDING TRIM, EDGE MOLDINGS,AND SUSPENSION MEMBERS. CLEANING a) AND ONE ADDITIONAL HINGE FOR EACH 30"OF ADDITIONAL HEIGHT OR SHOWN ON SCHEDULE. ALL DOORS WiTH CLOSERS SHALL AND TOUCH-UP OF MINOR FINISH DAMAGE SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS. REMOVE AND REPLACE WORK SHEET NUMBER: p HAVE BEARING HINGES. THAT CANNOT BE SUCCESSFULLY CLEANED AND REPAIRED TO PERMANENTLY ELIMINATE EVIDENCE OF DAMAGE. CV 1. O. 11 2 VISIBLE SIGNS OF TOUCH-UP OR REPAIR TO EXPOSED SURFACES SHALL NOT BE ACCEPTED. ti i I POWER AND COMMUNICATION NOTES ROLLER SHADES ROLLER SHADES (CONT.) ROLLER SHADES (CONT.) SURVEY FIELD CONDITIONS AND VERIFY THAT THE WORK IS FEASIBLE AS SHOWN. VERIFY THE LOCATION OF FLOOR RECEPTACLES PART 1 GENERAL 2.5 SHADE FABRICATION PART 3 EXECUTION .. AND OTHER RECEPTACLES IN RELATION TO STRUCTURAL AND OTHER ELEMENTS,AS REQUIRED. 1.1 SECTION INCLUDES A. ELECTRICALLY OPERATED DOUBLE-ROLLER SUNSCREEN AND ROOM-DARKENING SHADES. A. FABRICATE UNITS TO COMPLETELY FILL EXISTING OPENINGS FROM HEAD TO SILL AND JAMB-TO-JAMB, UNLESS SPECIFICALLY 3.1 EXAMINATION INSTALL UNDERWRITERS LABORATORIES(U.L.)LABELED DEVICES ONLY. B. LOCAL GROUP AND MASTER CONTROL SYSTEM FOR SHADE OPERATION. INDICATED OTHERWISE. C. LOCAL GROUP AND MASTER CONTROL SYSTEM FOR SHADE OPERATION WITH ADDRESSABLE MOTORS. A. DO NOT BEGIN INSTALLATION UNTIL SUBSTRATES HAVE BEEN PROPERLY PREPARED. ASD SKY TYPICAL DIMENSIONS TO RECEPTACLES ARE TO THE CENTER OF THE COVER PLATE. CLUSTERS OF RECEPTACLES ARE B. FABRICATE SHADECLOTH TO HANG FLAT WITHOUT BUCKLING OR DISTORTION. FABRICATE WITH HEAT-SEALED TRIMMED DIMENSIONED TO THE CENTER OF THE CLUSTER, UNLESS OTHERWISE NOTED. GANG COVERPLATES SHALL BE ONE-PIECE TYPE, 1.2 RELATED SECTIONS EDGES TO HANG STRAIGHT WITHOUT CURLING OR RAVELING. FABRICATE UNGUIDED SHADECLOTH TO ROLL TRUE AND STRAIGHT B. IF SUBSTRATE PREPARATION IS THE RESPONSIBILITY OF ANOTHER INSTALLER, NOTIFY ARCHITECT OF UNSATISFACTORY UNLESS NOTED OTHERWISE. WHERE GANGING IN A SINGLE COVER PLATE IS NOT POSSIBLE, MOUNT THE RECEPTACLES OR WITHOUT SHIFTING SIDEWAYS MORE THAN 1/8 INCH (3.18 MM) IN EITHER DIRECTION PER 8 FEET(2438 MM)OF SHADE HEIGHT DUE PREPARATION BEFORE PROCEEDING. SWITCHES SIDE BY SIDE WITH THE EDGES TOUCHING. A. SECTION 06100-ROUGH CARPENTRY: WOOD BLOCKING AND GROUNDS FOR MOUNTING ROLLER SHADES AND ACCESSORIES. TO WARP DISTORTION OR WEAVE DESIGN. FABRICATE HEM AS FOLLOWS: 1. BOTTOM HEM WEIGHTS. 3.2 PREPARATION DO NOT MOUNT J-BOXES/RECEPTACLES BACK TO BACK IN PARTITIONS. B. SECTION 09260-GYPSUM BOARD ASSEMBLIES: COORDINATION WITH GYPSUM BOARD ASSEMBLIES FOR INSTALLATION OF 2. CONCEALED HEMTUBE. SHADE POCKETS,CLOSURES AND RELATED ACCESSORIES. 3. EXPOSED BLACKOUT HEMBAR WITH LIGHT SEAL. A. CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION. FURNITURE AS SHOWN IN THE POWER AND COMMUNICATION PLAN IS FOR REFERENCE ONLY. C. SECTION 09510-ACOUSTICAL CEILINGS: COORDINATION WITH ACOUSTICAL CEILING SYSTEMS FOR INSTALLATION OF SHADE C. PROVIDE BATTENS IN STANDARD SHADES AS REQUIRED TO ASSURE PROPER TRACKING AND UNIFORM ROLLING OF THE B. PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE MANUFACTURER FOR ACHIEVING THE BEST RESULT FOR VERIFY ALL EQUIPMENT MOUNTING REQUIREMENTS FOR ALL ELECTRICAL,TELEPHONE AND OTHER EQUIPMENT INCLUDING SPECIAL POCKETS, CLOSURES AND RELATED ACCESSORIES. SHADEBANDS. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THE WIDTH-TO-HEIGHT(W:H) RATIOS SHALL NOT EXCEED THE SUBSTRATE UNDER THE PROJECT CONDITIONS. PLUG CONFIGURATIONS AND FURNITURE POWER POLES. MANUFACTURER'S STANDARDS OR, IN ABSENCE OF SUCH STANDARDS, SHALL BE RESPONSIBLE FOR ESTABLISHING D. DIVISION 16-ELECTRICAL: ELECTRIC SERVICE FOR MOTOR CONTROLS. APPROPRIATE STANDARDS TO ASSURE PROPER TRACKING AND ROLLING OF THE SHADECLOTH WITHIN SPECIFIED STANDARDS. 3.3 INSTALLATION THE ARCHITECTURAL DRAWINGS SHALL DETERMINE THE LOCATION OF OUTLETS AND OTHER RELATED POWER AND BATTENS SHALL BE ROLL-FORMED STAINLESS STEEL OR TEMPERED STEEL,AS REQUIRED. COMMUNICATIONS ELEMENTS. IN THE CASE OF CONFLICTS WITH THE ENGINEERING DRAWINGS,THE CONTRACTOR SHALL ASK THE 1.3 REFERENCES A. INSTALL ROLLER SHADES LEVEL, PLUMB, SQUARE,AND TRUE ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS,AND ARCHITECT FOR CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK. D. FOR RAILROADED SHADEBANDS, PROVIDE SEAMS IN RAILROADED MULTI-WIDTH SHADEBANDS AS REQUIRED TO MEET SIZE LOCATED SO SHADE BAND IS NOT CLOSER THAN 2 INCHES(50 MM)TO INTERIOR FACE OF GLASS. ALLOW PROPER CLEARANCES A.ASTM G 21 -STANDARD PRACTICE FOR DETERMINING RESISTANCE OF SYNTHETIC POLYMERIC MATERIALS TO FUNGI. REQUIREMENTS AND IN ACCORDANCE WITH SEAM ALIGNMENT AS ACCEPTABLE TO ARCHITECT. SEAMS SHALL BE PROPERLY FOR WINDOW OPERATION HARDWARE. COVER PLATES, SWITCHES, RECEPTACLES AND RELATED ITEMS SHALL BE'P&S' UNLESS NOTED OTHERWISE. COLORS SHALL BE LOCATED. FURNISH BATTENS IN PLACE OF PLAIN SEAMS WHEN THE WIDTH, HEIGHT, OR WEIGHT OF THE SHADE EXCEEDS 235 Pine Street VERIFIED WITH THE ARCHITECT. B. NFPA 70-NATIONAL ELECTRICAL CODE. MANUFACTURER'S STANDARDS. IN ABSENCE OF SUCH STANDARDS,ASSURE PROPER USE OF SEAMS OR BATTENS AS REQUIRED B.TURN-KEY SINGLE-SOURCE RESPONSIBILITY FOR MOTORIZED INTERIOR ROLLER SHADES: TO CONTROL THE RESPONSIBILITY TO,AND ASSURE THE PROPER TRACKING OF THE RAILROADED MULTI-WIDTH SHADEBANDS. FOR PERFORMANCE OF MOTORIZED ROLLER SHADE SYSTEMS,ASSIGN THE DESIGN, ENGINEERING,AND INSTALLATION OF Suite 2100 COORDINATE THE OWNER'S TELEPHONE, CABLING AND SECURITY INSTALLATION AS REQ. C. NFPA 701-99- FIRE TESTS FOR FLAME-RESISTANT TEXTILES AND FILMS. MOTORIZED ROLLER SHADE SYSTEMS, MOTORS, CONTROLS,AND LOW VOLTAGE ELECTRICAL CONTROL WIRING SPECIFIED IN E. PROVIDE BATTENS FOR RAILROADED SHADES WHEN WIDTH-TO-HEIGHT(W:H) RATIOS MEET OR EXCEED MANUFACTURER'S THIS SECTION TO A SINGLE MANUFACTURER AND THEIR AUTHORIZED INSTALLER/DEALER. THE ARCHITECT WILL NOT PRODUCE A San Francisco, CA 94104 REUSE EXISTING ELECTRICAL WORK WHERE POSSIBLE EXCEPT EXPOSED COVER PLATES, RECEPTACLES, SWITCHES, ETC. WHICH 1.4 SUBMITTALS STANDARDS. IN ABSENCE OF MANUFACTURER'S STANDARDS, BE RESPONSIBLE FOR PROPER USE AND PLACEMENT OF BATTENS SET OF ELECTRICAL DRAWINGS FOR THE INSTALLATION OF CONTROL WIRING FOR THE MOTORS, OR MOTOR CONTROLLERS OF SHALL BE NEW, UNLESS NOTED OTHERWISE. TO ASSURE PROPER TRACKING AND ROLL OF SHADEBANDS. THE MOTORIZED ROLLER SHADES. POWER WIRING(LINE VOLTAGE), SHALL BE PROVIDED BY THE ROLLER SHADE T 415.288.8670 A. SUBMIT UNDER PROVISIONS OF SECTION 01300. INSTALLER/DEALER, IN ACCORDANCE WITH THE REQUIREMENTS PROVIDED BY THE MANUFACTURER. COORDINATE THE F 415.288.8676 THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE OWNER'S FURNITURE VENDOR TO F. BLACKOUT SHADEBANDS,WHEN USED IN SIDE CHANNELS, SHALL HAVE HORIZONTALLY MOUNTED, ROLL-FORMED STAINLESS FOLLOWING WITH THE ROLLER SHADE INSTALLER/DEALER: DISCONNECT&RECONNECT POWER TO ALL SYSTEMS FURNITURE FOR TEMPORARY MOVES&FINAL MOVES OF FURNITURE DURING B. SUBMIT ENVIRONMENTAL CERTIFICATION AND THIRD PARTY EVALUATION PER SECTION 1.5 QUALIFICATIONS. STEEL OR TEMPERED-STEEL BATTENS NOT MORE THAN 3 FEET(115 MM)ON CENTER EXTENDING FULLY INTO THE SIDE 1. MAIN CONTRACTOR SHALL PROVIDE POWER PANELS AND CIRCUITS OF SUFFICIENT SIZE TO ACCOMMODATE ROLLER SHADE ALL PHASES OF CONSTRUCTION. CHANNELS. BATTENS SHALL BE CONCEALED IN A INTEGRALLY-COLORED FABRIC TO MATCH THE INSIDE AND OUTSIDE COLORS OF MANUFACTURER'S REQUIREMENTS,AS INDICATED ON THE MECHANICAL AND ELECTRICAL DRAWINGS. WWW.aSdSky.COCn C. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH PRODUCT TO BE USED, INCLUDING: THE SHADEBAND, IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED STANDARDS FOR SPACING AND REQUIREMENTS. 2. MAIN CONTRACTOR SHALL COORDINATE WITH REQUIREMENTS OF ROLLER SHADE INSTALLER/DEALER, BEFORE INACCESSIBLE ALL NEW RECEPTACLES MOUNTED AT COUNTER HEIGHT SHALL BE INSTALLED HORIZONTALLY ABOVE THE COUNTER OR ABOVE THE 1. PREPARATION INSTRUCTIONS AND RECOMMENDATIONS. 1. BATTENS SHALL BE ROLL FORMED OF STAINLESS STEEL OR TEMPERED STEEL AND CONCAVE TO MATCH THE CONTOUR OF AREAS ARE CONSTRUCTED. BACKSPLASH, SHOULD THERE BE ONE. 2. STYLES, MATERIAL DESCRIPTIONS, DIMENSIONS OF INDIVIDUAL COMPONENTS, PROFILES, FEATURES, FINISHES AND OPERATING THE ROLLER TUBE. 3. ROLLER SHADE INSTALLER/DEALER SHALL RUN LINE VOLTAGE AS DEDICATED HOME RUNS(OF SUFFICIENT QUANTITY, IN INSTRUCTIONS. 2. BATTEN POCKETS SHALL BE SELF-COLORED FABRIC FRONT AND BACK RF WELDED INTO THE SHADECLOTH.A SELF-COLOR SUFFICIENT CAPACITY AS REQUIRED)TERMINATING IN JUNCTION BOXES IN LOCATIONS DESIGNATED BY ROLLER SHADE DEALER. ALL RECEPTACLES ADJACENT TO WET AREAS SHALL BE GROUND FAULT INTERRUPTOR TYPE, UNLESS SPECIFICALLY NOTED 3. STORAGE AND HANDLING REQUIREMENTS AND RECOMMENDATIONS. OPAQUE LINER SHALL BE PROVIDED FRONT AND BACK TO ELIMINATE ANY SEE THROUGH OF THE BATTEN POCKET THAT SHALL 4. ROLLER SHADE INSTALLER/DEALER SHALL PROVIDE AND RUN ALL LINE VOLTAGE(FROM THE TERMINATING POINTS)TO THE OTHERWISE. 4. MOUNTING DETAILS AND INSTALLATION METHODS. NOT EXCEED 1-1/2 INCHES(38.1 MM)HIGH AND BE TOTALLY OPAQUE.A SEE-THROUGH MOIRE EFFECT,WHICH OCCURS WITH MOTOR CONTROLLERS,WIRE ALL ROLLER SHADE MOTORS TO THE MOTOR CONTROLLERS,AND PROVIDE AND RUN LOW 5.TYPICAL WIRING DIAGRAMS INCLUDING INTEGRATION OF MOTOR CONTROLLERS WITH BUILDING MANAGEMENT SYSTEM, MULTIPLE LAYERS OF TRANSPARENT FABRICS, SHALL NOT BE ACCEPTABLE. VOLTAGE CONTROL WIRING FROM MOTOR CONTROLLERS TO SWITCH/CONTROL LOCATIONS DESIGNATED BY THE ARCHITECT. THE ARCHITECT SHALL HAVE FINAL LOCATION APPROVAL OF ALL WALL MOUNTED CONTROLS AND/OR DEVICES INCLUDING BUT NOT AUDIOVISUAL AND LIGHTING CONTROL SYSTEMS AS APPLICABLE. ALL ABOVE-CEILING AND CONCEALED WIRING SHALL BE PLENUM-RATED, OR INSTALLED IN CONDUIT,AS REQUIRED BY THE LIMITED TO: THERMOSTATS, HORNS, STROBE LIGHTS, SECURITY DEVICES, FIRE ALARM PULL STATIONS, ETC. 2.6 COMPONENTS ELECTRICAL CODE HAVING JURISDICTION. D. SHOP DRAWINGS: PLANS, ELEVATIONS, SECTIONS, PRODUCT DETAILS, INSTALLATION DETAILS,OPERATIONAL CLEARANCES, 5. MAIN CONTRACTOR SHALL PROVIDE CONDUIT WITH PULL WIRE IN ALL AREAS, WHICH MIGHT NOT BE ACCESSIBLE TO ROLLER THE CONTRACTOR SHALL PROVIDE A COMPLETE ELECTRICAL INSTALLATION INCLUDING WORK CUSTOMARILY INCLUDED IN THE WIRING DIAGRAMS AND RELATIONSHIP TO ADJACENT WORK. A.ACCESS AND MATERIAL REQUIREMENTS: SHADE CONTRACTOR DUE TO BUILDING DESIGN, EQUIPMENT LOCATION OR SCHEDULE. WORK IF NOT SPECIFICALLY CALLED OUT. 1. PREPARE SHOP DRAWINGS ON AUTOCAD OR MICROSTATION FORMAT USING BASE SHEETS PROVIDED ELECTRONICALLY BY THE 1. PROVIDE SHADE HARDWARE ALLOWING FOR THE REMOVAL OF SHADE ROLLER TUBE FROM BRACKETS WITHOUT REMOVING ARCHITECT. HARDWARE FROM OPENING AND WITHOUT REQUIRING END OR CENTER SUPPORTS TO BE REMOVED. C.ADJUST AND BALANCE ROLLER SHADES TO OPERATE SMOOTHLY, EASILY, SAFELY,AND FREE FROM BINDING OR MALFUNCTION 2. PROVIDE SHADE HARDWARE THAT ALLOWS FOR REMOVAL AND RE-MOUNTING OF THE SHADE BANDS WITHOUT HAVING TO THROUGHOUT ENTIRE OPERATIONAL RANGE. E.WINDOW TREATMENT SCHEDULE: FOR ALL ROLLER SHADES. USE SAME ROOM DESIGNATIONS AS INDICATED ON THE REMOVE THE SHADE TUBE, DRIVE OR OPERATING SUPPORT BRACKETS. DRAWINGS AND INCLUDE OPENING SIZES AND KEY TO TYPICAL MOUNTING DETAILS. 3. USE ONLY DELRIN ENGINEERED PLASTICS BY DUPONT FOR ALL PLASTIC COMPONENTS OF SHADE HARDWARE. STYRENE D. CLEAN ROLLER SHADE SURFACES AFTER INSTALLATION,ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. BASED PLASTICS,AND/OR POLYESTER, OR REINFORCED POLYESTER WILL NOT BE ACCEPTABLE. F.SELECTION SAMPLES: FOR EACH FINISH PRODUCT SPECIFIED,ONE SET OF SHADE CLOTH OPTIONS AND ALUMINUM FINISH E. ENGAGE INSTALLER TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST,OPERATE AND MAINTAIN ROLLER SHADE COLOR SAMPLES REPRESENTING MANUFACTURER'S FULL RANGE OF AVAILABLE COLORS AND PATTERNS. B. MOTORIZED SHADE HARDWARE AND SHADE BRACKETS: SYSTEMS. 1. PROVIDE SHADE HARDWARE CONSTRUCTED OF MINIMUM 1/8-INCH (3.18 MM)THICK PLATED STEEL, OR HEAVIER,THICKER,AS G.VERIFICATION SAMPLES: FOR EACH FINISH PRODUCT SPECIFIED, ONE COMPLETE SET OF SHADE COMPONENTS, REQUIRED TO SUPPORT 150 PERCENT OF THE FULL WEIGHT OF EACH SHADE. 3.4 PROTECTION UNASSEMBLED, DEMONSTRATING COMPLIANCE WITH SPECIFIED REQUIREMENTS. SHADECLOTH SAMPLE AND ALUMINUM FINISH 2. PROVIDE SHADE HARDWARE SYSTEM THAT ALLOWS FOR FIELD ADJUSTMENT OF MOTOR OR REPLACEMENT OF ANY OPERABLE SAMPLE AS SELECTED. MARK FACE OF MATERIAL TO INDICATE INTERIOR FACES. HARDWARE COMPONENT WITHOUT REQUIRING REMOVAL OF BRACKETS, REGARDLESS OF MOUNTING POSITION (INSIDE, OR A. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT. OUTSIDE MOUNT). H. MAINTENANCE DATA: METHODS FOR MAINTAINING ROLLER SHADES, PRECAUTIONS REGARDING CLEANING MATERIALS AND 3. PROVIDE SHADE HARDWARE SYSTEM THAT ALLOWS FOR OPERATION OF MULTIPLE SHADE BANDS OFFSET BY A MAXIMUM OF B.TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE SUBSTANTIAL COMPLETION. METHODS, INSTRUCTIONS FOR OPERATING HARDWARE AND CONTROLS. 8-45 DEGREES FROM THE MOTOR AXIS BETWEEN SHADE BANDS(4-22.5 DEGREES)ON EACH SIDE OF THE RADIAL LINE, BY A •- SINGLE SHADE MOTOR(MULTI-BANDED SHADE, SUBJECT TO MANUFACTURER'S DESIGN CRITERIA). THE 1.5 QUALITY ASSURANCE END OF SECTION 2.7 SHADE MOTOR DRIVE SYSTEM A. MANUFACTURER QUALIFICATIONS: OBTAIN ROLLER SHADES THROUGH ONE SOURCE FROM A SINGLE MANUFACTURER WITH A PARTNERS MINIMUM OF TWENTY YEARS EXPERIENCE IN MANUFACTURING PRODUCTS COMPARABLE TO THOSE SPECIFIED IN THIS SECTION. A. SHADE MOTORS: 1.TUBULAR,ASYNCHRONOUS(NON-SYNCHRONOUS) MOTORS,WITH BUILT-IN REVERSIBLE CAPACITOR OPERATING AT 110V AC B. INSTALLER QUALIFICATIONS: INSTALLER TRAINED AND CERTIFIED BY THE MANUFACTURER WITH A MINIMUM OF TEN YEARS (60HZ), SINGLE PHASE, TEMPERATURE CLASS A,THERMALLY PROTECTED,TOTALLY ENCLOSED, MAINTENANCE FREE WITH LINE EXPERIENCE IN INSTALLING PRODUCTS COMPARABLE TO THOSE SPECIFIED IN THIS SECTION. VOLTAGE POWER SUPPLY EQUIPPED WITH LOCKING DISCONNECT PLUG ASSEMBLY FURNISHED WITH EACH MOTOR. 11 85 AVE. 2. CONCEAL MOTORS INSIDE SHADE ROLLER TUBE. C. FIRE-TEST-RESPONSE CHARACTERISTICS: PASSES NFPA 701-99 SMALL AND LARGE-SCALE VERTICAL BURN. MATERIALS TESTED 3. MAXIMUM CURRENT DRAW FOR EACH SHADE MOTOR OF 2.3 AMPS. SUITE 100 SHALL BE IDENTICAL TO PRODUCTS PROPOSED FOR USE. 4. USE MOTORS RATED AT THE SAME NOMINAL SPEED FOR ALL SHADES IN THE SAME ROOM. PORTLAND, OR D. ELECTRICAL COMPONENTS: NFPA ARTICLE 100 LISTED AND LABELED BY EITHER UL OR ETL OR OTHER TESTING AGENCY B. TOTAL HANGING WEIGHT OF SHADE BAND SHALL NOT EXCEED 80 PERCENT OF THE RATED LIFTING CAPACITY OF THE SHADE 97223 ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, MARKED FOR INTENDED USE,AND TESTED AS A SYSTEM. INDIVIDUAL MOTOR AND TUBE ASSEMBLY. TESTING OF COMPONENTS WILL NOT BE ACCEPTABLE IN LIEU OF SYSTEM TESTING. 2.8 MOTOR CONTROL SYSTEMS E.ANTI-MICROBIAL CHARACTERISTICS: 'NO GROWTH'PER ASTM G 21 RESULTS FOR FUNGI ATCC9642,ATCC 964.4,ATCC9645. A. SPECIFICATIONS AND DESIGN OF SHADE MOTORS AND MOTOR CONTROL SYSTEM MAY BE ACCEPTABLE PROVIDE THAT ALL OF F. ENVIRONMENTAL CERTIFICATION: SUBMIT WRITTEN CERTIFICATION FROM THE MANUFACTURER, INCLUDING THIRD PARTY THE FOLLOWING PERFORMANCE CAPABILITIES ARE PROVIDED. MOTOR LOGIC CONTROL SYSTEMS NOT IN COMPLETE EVALUATION, RECYCLING CHARACTERISTICS,AND PERPETUAL USE CERTIFICATION AS SPECIFIED BELOW. INITIAL SUBMITTALS, COMPLIANCE WITH THESE PERFORMANCE CRITERIA SHALL NOT BE ACCEPTED AS EQUAL SYSTEMS. WHICH DO NOT INCLUDE THE ENVIRONMENTAL CERTIFICATION, BELOW WILL BE REJECTED. MATERIALS THAT ARE SIMPLY'PVC 1. MOTOR CONTROL SYSTEM: FREE'WITHOUT IDENTIFYING THEIR INPUTS SHALL NOT QUALIFY AS MEETING THE INTENT OF THIS SPECIFICATION AND SHALL BE A. PROVIDE POWER TO EACH SHADE MOTOR VIA INDIVIDUAL 3 CONDUCTOR LINE VOLTAGE CIRCUITS CONNECTING EACH MOTOR REJECTED. TO THE RELAY BASED MOTOR LOGIC CONTROLLERS (IQ/MLC). B. CONTROL SYSTEM COMPONENTS SHALL PROVIDE APPROPRIATE(SPIKE AND BROWN OUT) OVER-CURRENT PROTECTION (+/- 10 G.THIRD PARTY EVALUATION: PROVIDE DOCUMENTATION STATING THE SHADE CLOTH HAS UNDERGONE THIRD PARTY PERCENT OF LINE VOLTAGE) FOR EACH OF THE FOUR INDIVIDUAL MOTOR CIRCUITS AND SHALL BE RATED BY UL OR ETL AS A EVALUATION FOR ALL CHEMICAL INPUTS, DOWN TO A SCALE OF 100 PARTS PER MILLION,THAT HAVE BEEN EVALUATED FOR RECOGNIZED COMPONENT OF THIS SYSTEM AND TESTED AS AN INTEGRATED SYSTEM. HUMAN AND ENVIRONMENTAL SAFETY. IDENTIFY ANY AND ALL INPUTS,WHICH ARE KNOWN TO BE CARCINOGENIC, MUTAGENIC, C. MOTOR CONTROL SYSTEM SHALL ALLOW EACH GROUP OF FOUR SHADE MOTORS IN ANY COMBINATION TO BE CONTROLLED TERATOGENIC, REPRODUCTIVELY TOXIC, OR ENDOCRINE DISRUPTING. ALSO IDENTIFY ITEMS THAT ARE TOXIC TO AQUATIC BY EACH OF FOUR LOCAL SWITCH PORTS,WITH UP TO FOURTEEN POSSIBLE"SUB-GROUP"COMBINATIONS VIA LOCAL 3 BUTTON SYSTEMS, CONTAIN HEAVY METALS,OR ORGANOHALOGENS. THE MATERIAL SHALL CONTAIN NO INPUTS THAT ARE KNOWN WALL SWITCHES AND ALL AT ONCE VIA A MASTER 3 BUTTON SWITCH. SYSTEM SHALL ALLOW FOR OVERLAPPING SWITCH PROBLEMS TO HUMAN OR ENVIRONMENTAL HEALTH PER THE ABOVE MAJOR CRITERIA, EXCEPT FOR AN INPUT THAT IS REQUIRED COMBINATIONS FROM TWO OR MORE LOCAL SWITCHES. TO MEET LOCAL FIRE CODES. D. MULTIPLE"SUB-GROUPS"FROM DIFFERENT IQ/MLC CONTROL COMPONENTS SHALL BE CAPABLE OF BEING COMBINED TO FORM"GROUPS"OPERATED BY A SINGLE 3 BUTTON WALL SWITCH, FROM EITHER THE MASTER PORT OR IN SERIES FROM A H. RECYCLING CHARACTERISTICS: PROVIDE DOCUMENTATION THAT THE SHADE CLOTH CAN AND IS PART OF A CLOSED LOOP OF LOCAL SWITCH PORT. PERPETUAL USE AND NOT BE REQUIRED TO BE DOWN CYCLED, INCINERATED OR OTHERWISE THROWN AWAY. SCRAP MATERIAL E. EACH SHADE MOTOR SHALL BE ACCESSIBLE(FOR CONTROL PURPOSES) FROM UP TO FOUR LOCAL SWITCHES AND ONE CAN BE SENT BACK TO THE MILL FOR REPROCESSING AND RECYCLING INTO THE SAME QUALITY YARN AND WOVEN INTO NEW MASTER SWITCH. MATERIAL, WITHOUT DOWN CYCLING. CERTIFY THAT THIS PROCESS IS CURRENTLY UNDERWAY AND WILL BE UTILIZED FOR THIS F. CONTROL SYSTEM SHALL ALLOW FOR AUTOMATIC ALIGNMENT OF SHADE HEM BARS IN STOPPED POSITION AT 25 PERCENT, 50 " PROJECT. PERCENT,AND 75 PERCENT OF OPENING HEIGHTS,AND UP TO THREE USER-DEFINED INTERMEDIATE STOPPING POSITIONS IN ADDITION TO ALL UP/ALL DOWN, REGARDLESS OF SHADE HEIGHT, FOR A TOTAL OF FIVE POSITIONS. CONTROL SYSTEM SHALL I. PERPETUAL USE CERTIFICATION: CERTIFY THAT AT THE END OF THE USEFUL LIFE OF THE SHADE CLOTH,THAT THE MATERIAL ALLOW SHADES TO BE STOPPED AT ANY POINT IN THE OPENING HEIGHT NOTING THAT SHADES MAY NOT BE IN ALIGNMENT AT CAN BE SENT BACK TO THE MANUFACTURER FOR RECAPTURE AS PART OF A CLOSED LOOP OF PERPETUAL USE AND THAT THE THESE NON-DEFINED POSITIONS). MATERIAL CAN AND WILL BE RECONSTITUTED INTO NEW YARN, FOR WEAVING INTO NEW SHADE CLOTH. PROVIDE INFORMATION G.CONTROL SYSTEM SHALL HAVE TWO STANDARD OPERATING MODES: NORMAL MODE ALLOWING THE SHADES TO BE STOPPED ON EACH SHADE BAND INDICATING THAT THE SHADE BAND CAN BE SENT BACK TO THE MANUFACTURER FOR THIS PURPOSE. ANYWHERE IN THE WINDOW'S OPENING HEIGHT AND UNIFORM MODE,ALLOWING THE SHADES TO ONLY BE STOPPED AT THE PREDEFINED INTERMEDIATE STOP POSITIONS. BOTH MODES SHALL ALLOW FOR ALL UP/ALL DOWN POSITIONING. 1.6 DELIVERY, STORAGE,AND HANDLING H. CONTROL SYSTEM COMPONENTS SHALL ALLOW FOR INTERFACE WITH BOTH AUDIOVISUAL SYSTEM COMPONENTS AND BUILDING FIRE AND LIFE SAFETY SYSTEM VIA A DRY CONTACT TERMINAL BLOCK. A. DELIVER SHADES IN FACTORY-LABELED PACKAGES, MARKED WITH MANUFACTURER AND PRODUCT NAME, FIRE-TEST- I. CONTROL SYSTEM COMPONENTS SHALL ALLOW FOR INTERFACE WITH EXTERNAL ANALOG INPUT CONTROL DEVICES SUCH AS RESPONSE CHARACTERISTICS,AND LOCATION OF INSTALLATION USING SAME ROOM DESIGNATIONS INDICATED ON DRAWINGS SOLAR ACTIVATED CONTROLLERS,24 HOUR TIMERS,AND SIMILAR ITEMS;VIA A DRY CONTACT TERMINAL BLOCK. AND IN THE WINDOW TREATMENT SCHEDULE. J. RECONFIGURATION OF SWITCH GROUPS SHALL NOT REQUIRE REWIRING OF THE HARDWIRED LINE VOLTAGE MOTOR POWER SUPPLY WIRING,OR THE LOW VOLTAGE CONTROL WIRING. RECONFIGURATION OF SWITCH GROUPS SHALL BE ACCOMPLISHED 1.7 PROJECT CONDITIONS WITHIN THE MOTOR CONTROL DEVICE(IQ/MLC). 2.WALL SWITCHES: A. ENVIRONMENTAL LIMITATIONS: INSTALL ROLLER SHADES AFTER FINISH WORK INCLUDING PAINTING IS COMPLETE AND AMBIENT A. THREE-BUTTON ARCHITECTURAL FLUSH MOUNTED SWITCHES WITH METAL COVER PLATE AND NO EXPOSED FASTENERS. TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR PROJECT WHEN OCCUPIED FOR ITS B. CONNECT LOCAL WALL SWITCHES TO CONTROL SYSTEM COMPONENTS VIA LOW VOLTAGE(12V DC)4-CONDUCTOR MODULAR A ,D A/ , INTENDED USE. CABLE EQUIPPED WITH RJ-11 TYPE CONNECTORS SUPPLIED, INSTALLED AND CERTIFIED UNDER DIVISION 16-ELECTRICAL. C. CONNECT MASTER WALL SWITCHES TO CONTROL SYSTEM COMPONENTS VIA LOW VOLTAGE(12V DC)6-CONDUCTOR JOSEPH A.REMUNG '�,y 1.8 WARRANTY MODULAR CABLE EQUIPPED WITH RJ-12 TYPE CONNECTORS SUPPLIED, INSTALLED AND CERTIFIED UNDER DIVISION 16- t^,I ELECTRICAL. + ,, 6526 y A. ROLLER SHADE HARDWARE,AND SHADECLOTH (EXCEPT ECOVEIL?): MANUFACTURER'S STANDARD NON-DEPRECIATING ,�' N tl�n�clscc�.�! TWENTY-FIVE YEAR LIMITED WARRANTY. 2.9 ACCESSORIES ca. + 1. ECOVEIL STANDARD NON-DEPRECIATING 10-YEAR LIMITED WARRANTY. A. ROLLER SHADE POCKET FOR RECESSED MOUNTING IN ACOUSTICAL TILE, OR DRYWALL CEILINGS AS INDICATED ON THE O B. ROLLER SHADE MOTORS AND MOTOR CONTROL SYSTEMS: MANUFACTURER'S STANDARD NON-DEPRECIATING FIVE-YEAR DRAWINGS. WARRANTY. 1. PROVIDE EITHER EXTRUDED ALUMINUM AND OR FORMED STEEL SHADE POCKET, SIZED TO ACCOMMODATE ROLLER SHADES, WITH EXPOSED EXTRUDED ALUMINUM CLOSURE MOUNT, TILE SUPPORT AND REMOVABLE CLOSURE PANEL TO PROVIDE ACCESS C. ROLLER SHADE INSTALLATION: ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION, NOT INCLUDING SCAFFOLDING, LIFTS OR TO SHADES. OTHER MEANS TO REACH INACCESSIBLE AREAS. B. FASCIA: PART 2 PRODUCTS 1. CONTINUOUS REMOVABLE EXTRUDED ALUMINUM FASCIA THAT ATTACHES TO SHADE MOUNTING BRACKETS WITHOUT THE USE OF ADHESIVES, MAGNETIC STRIPS, OR EXPOSED FASTENERS. 2.1 MANUFACTURERS 2. FASCIA SHALL BE ABLE TO BE INSTALLED ACROSS TWO OR MORE SHADE BANDS IN ONE PIECE. 3. FASCIA SHALL FULLY CONCEAL BRACKETS, SHADE ROLLER AND FABRIC ON THE TUBE. A.ACCEPTABLE MANUFACTURER: MECHOSHADE SYSTEMS, INC.;42-03 35TH STREET, LONG ISLAND CITY, NY 11101. TEL: (718) 4. PROVIDE BRACKET/FASCIA END CAPS WHERE MOUNTING CONDITIONS EXPOSE OUTSIDE OF ROLLER SHADE BRACKETS. 729-2020. FAX: (718)729-2941. EMAIL: INFO@MECHOSHADE.COM, WWW.MECHOSHADE.COM. C. ROOM DARKENING SIDE AND/OR SILL CHANNELS: B. SUBSTITUTIONS: OR APPROVED EQUAL/BETTER. 1. EXTRUDED ALUMINUM WITH POLYBOND EDGE SEALS AND SNAPLOC-MOUNTING BRACKETS AND WITH CONCEALED FASTENING. 0 EXPOSED FASTING IS NOT ACCEPTABLE. CHANNELS SHALL ACCEPT ONE-PIECE EXPOSED BLACKOUT HEMBAR WITH VINYL SEALThis drawing is the property of Associated o C. REQUESTS FOR SUBSTITUTIONS WILL BE CONSIDERED IN ACCORDANCE WITH PROVISIONS OF SECTION 01600. TO ASSURE SIDE LIGHT CONTROL AND SILL LIGHT CONTROL. Space Design,Inc.and is not to be a) MECHOSHADE SIDE CHANNELS, 1-15/16 INCHES(49.2 MM)WIDE BY 1-3/16 INCHES(30.1 MM)DEEP,TWO-BAND CENTER CHANNELS, reproduced or copied in whole or part.It is D.ALTERNATES:THE FOLLOWING PRODUCTS AND MANUFACTURERS MAY BE BID AS AN ALTERNATE PRODUCT IN ACCORDANCE 2-5/8 INCHES(66.6 MM)WIDE BY 1-3/16 INCHES(30.1 MM) DEEP.THE 2-5/8-INCH(66.6 MM)DOUBLE-CENTER CHANNELS MAY BE not to be used on any other project and is to -5)) WITH SECTION 01030.ANY PRICING FOR ALTERNATE PRODUCTS SHALL BE LISTED SEPARATELY FROM THE BASE BID SPECIFIED INSTALLED AT CENTER-SUPPORT POSITIONS OF MULTI-BAND-SHADE**NOTE TO SPECIFIER** DELETE ONE OF THE TWO be returned upon request.Scales as stated PRODUCT. ANY ALTERNATE PRICING MUST INCLUDE LINE-BY-LINE COMPLIANCE OR NON-COMPLIANCE WITH THE SPECIFICATIONS. FOLLOWING PARAGRAPHS. herein are for reference only as normal c3 IF THE ALTERNATE PRODUCT IS ACCEPTABLE TO THE ARCHITECT,THE SPECIFIED MANUFACTURER WILL BE GIVEN THE A. COLOR: SELECTED FROM MANUFACTURER'S STANDARD COLORS. reproduction processes may alter the o OPPORTUNITY TO PROVIDE AN EQUIVALENT PROPOSAL. accuracy of original drawings. Q 1. SUBURBAN/2 SHADE SYSTEM BY MECHOSHADE SYSTEMS, INC. Associated Space Design, Inc.2014 J 2. CASTEC WINDOW SHADING INC. I Q 3. NYSAN fX 4. LUTRON Z 2.2 APPLICATIONS/SCOPE W U A. ROLLER SHADE SCHEDULE: 1. MOTORIZED INTERIOR"DOUBLE", SOLAR AND ROOM DARKENING BLACKOUT ROLLER SHADES, OPERATING INDEPENDENTLY OF O EACH OTHER, IN ALL EXTERIOR WINDOWS OF ROOMS AND SPACES SHOWN ON DRAWINGS,AND RELATED MOTOR CONTROL E SYSTEMS. E 2.3 SHADE CLOTH U N v A.VISUALLY TRANSPARENT SINGLE-FABRIC SHADECLOTH: SINGLE THICKNESS NON-RAVELING 0.030-INCH (0.762 MM)THICK VINYL C FABRIC,WOVEN FROM 0.018-INCH (0.457 MM) DIAMETER EXTRUDED VINYL YARN COMPRISING OF 21 PERCENT POLYESTER AND 79 •� PERCENT REINFORCED VINYL, IN COLORS SELECTED FROM MANUFACTURER'S AVAILABLE RANGE. I- 1. 10 PERCENT OPEN, 2 BY 2 OPEN BASKET-WEAVE PATTERN. 'o 2. COLOR: SELECTED FROM MANUFACTURER'S STANDARD COLORS. ca v B.VINYL ROOM DARKENING SHADECLOTH (SINGLE-FABRIC): BLACKOUT MATERIAL,WASHABLE AND COLORFAST LAMINATED AND I , EMBOSSED VINYL COATED FABRIC, 0.012 INCHES THICK(0.30 MM)BLACKOUT MATERIAL AND WEIGHING 0.81 LBS. PER SQUARE 0 YARD,WITH A MINIMUM OF 62 THREADS PER SQUARE INCH IN COLORS SELECTED FROM MANUFACTURER'S AVAILABLE RANGE. Q.. 1. COLOR: SELECTED FROM MANUFACTURER'S STANDARD COLORS. 0 07.01.19 ISSUED FOR PERMIT 2.4 SHADE BAND NO: DATE: REMARKS: 0 A. SHADE BANDS: CONSTRUCTION OF SHADE BAND INCLUDES THE FABRIC,THE HEM WEIGHT, HEM-POCKET, SHADE ROLLER REVISIONS: o00o TUBE,AND THE ATTACHMENT OF THE SHADE BAND TO THE ROLLER TUBE. SEWN HEMS AND OPEN HEM POCKETS ARE NOT DRAWING TITLE:EPTABLE. nl ) 1.AHEM POCKETS AND HEM WEIGHTS: FABRIC HEM POCKET WITH RF-WELDED SEAMS(INCLUDING WELDED ENDS)AND SPECIFICATIONS CONCEALED HEM WEIGHTS. HEM WEIGHTS SHALL BE OF APPROPRIATE SIZE AND WEIGHT FOR SHADE BAND. HEM WEIGHT SHALL BE CONTINUOUS INSIDE A SEALED HEM POCKET. HEM POCKET CONSTRUCTION AND HEM WEIGHTS SHALL BE SIMILAR, FOR ALL E SHADES WITHIN ONE ROOM. O 2. SHADE BAND AND SHADE ROLLER ATTACHMENT: PROJECT NO.: ISSUE DATE: 0 A. USE EXTRUDED ALUMINUM SHADE ROLLER TUBE OF A DIAMETER AND WALL THICKNESS REQUIRED TO SUPPORT SHADE FABRIC . • WITHOUT EXCESSIVE DEFLECTION. ROLLER TUBES LESS THAN 1.55 INCH (39.37 MM) IN DIAMETER FOR MANUAL SHADES,AND LESS 28021.00 07.01.19 -0- THAN 2.55 INCHES(64.77 MM) FOR MOTORIZE SHADES ARE NOT ACCEPTABLE. DRAWN BY: CHECKED BY: IY B. PROVIDE FOR POSITIVE MECHANICAL ENGAGEMENT WITH DRIVE/BRAKE MECHANISM. .._ C. PROVIDE FOR POSITIVE MECHANICAL ATTACHMENT OF SHADE BAND TO ROLLER TUBE; SHADE BAND SHALL BE MADE ;n REMOVABLE/REPLACEABLE WITH A"SNAP-ON"SNAP-OFF"SPLINE MOUNTING,WITHOUT HAVING TO REMOVE SHADE ROLLER SHEET NUMBER: a) FROM SHADE BRACKETS. D. MOUNTING SPLINE SHALL NOT REQUIRE USE OF ADHESIVES,ADHESIVE TAPES, STAPLES,AND/OR RIVETS. -:-. E.ANY METHOD OF ATTACHING SHADE BAND TO ROLLER TUBE THAT REQUIRES THE USE OF:ADHESIVE,ADHESIVE TAPES, mums CTAA 91 S=S AAIRtriD D11/1TQ AD= torn-AC'f`CDTADI C -_. . . I I INIII .1---i fY \ \,,.,.,,,--'' , • \ ASD SKY O EXIT#1 —/ app j, �. ..‘0<(;,>i\ , /. .,,,,,,, ,,.,„ , / ,. , , . 1 ii, -------- • , .. ,. , , _, _ _ , „ , , , , ... , \ _._ • . . ,._._. „,„,,, . _._,.. \ \\ —11401p— _ Los'-6”t i —_ , LONGEST DIAGONAL \,..____ _ ......... -.0- .ii... _ \ ;4,,,\.... ' — � — _ � _ _ \\ 920 SIN 6th Avenue / � � � E-A-0..$3,-0 ,,2„ 1 — \... � _ — _ � 12th Floor ....Ail !., x_,.., . .... . s „ : �vEPq�r�oN / Portland, OR 6�iZ `oN � / O 1� � `'J -,.-- ._._ Ill'il -r ,.,,.,„„\\\,„ :ix \ \ T 678,491 .3773 .o....., r,- - ��cs .,---.,.. _ (A.....0„,00•__•,_..1\16 vvp www.asdsky.com / / .... .... ..........: ....:: \ • /� \ t\ 1 / /�,_,, ____. . r,,,, .... ____„____ ( I7 1 • _ . \,.._ \),H ,:..____.. ,.. . . ... ,•-•1 .. _ , ..... . • ,, / i L ____. . _ ____.. _. .) . I, ------ lt 1 ---,\:, •••••01°°1111°111.1 . THE • • :,:.\\:. \ .,:,/ PARTNERS _ � _ - GROUP — 11850 SW 67TH AVE. r _2$4, _01!2"_A%- _ SUITE 00 aui>,DwGO f _ _ _ r„...... / PORTLAND, OR 11 - - - �� \� ,/,/ ' '-- 7 _ _ , _ _ _ , _ ,,, : _. 1----'\; _ , _ ,_ 97223 //, \ / _ \ // -•=------ .„ .... ,- [ . .... .„ — 'to.. — . .\____\ 4. - fI • 1 • — i / i i _____--) j--- _._ i ____-) ____,,, // r J 1.7 si �OSEPH A.RENILtNG 6526 .E di 1,ANE F HItNC 15CO Fps:��['�” . __ 1.74 1 1 1ST FLOOR - LIFE SAFETY PLAN 1 /8" = 11-0" This drawing is the property of Associated Space Design, Inc. and is not to be - reproduced or copied in whole or part. It is SYMBOL DESCRIPTION SYMBOL DESCRIPTION V. OCCUPANCY CLASSIFICATION 1$T FLOQR PLUMBING CALCULATIQNS VIII. FIRE PROTECTION REQUIREMENTS not to be used on any other project and is to A. CLASSIFICATION TYPE: BUSINESS, GROUP B NFPA 6.1.1 [BUSINESS OCCUPANCY: 189 OCCUPANTS (95 WOMEN/95 MEN)] A. MANUAL FIRE ALARM BOXES: MAX. 5 FT. FROM EACH EXIT be returned upon request. Scales as stated B. CONSTRUCTION AREA: 1ST FLOOR- 3,730 SQ. FT. /2ND FLOOR-21,322 SQ. FT. NFPA 7.3.1.2 B. VISIBLE ALARMS REQUIRED IN PUBLIC AREAS herein are for reference only as normal C. TENANT'S OCCUPANT LOAD: 1ST FLOOR- 34/2ND FLOOR- 309 C. REFER TO MEP DOCUMENTS reproduction processes may alter the ) DISTANCE TRAVELING Occupant Load Schedule - 1st Floor D. FIRE EXTINGUISHER REQUIREMENTS PER: NFPA 10 (1-6)TABLE 3-2.1 (LIGHT HAZARD OCCUPANCY) accuracy of original drawings. II11i 1-HR RATED WALLMEN REQ'D PROVIDED, E. MAXIMUM FLOOR AREA PER UNIT OF A 3,000 SQ. FT. Associated Space Design, Inc. 2016 Load Factor SF/Person Area Occupant Load WC + URINALS 2.89 4 F. MAXIMUM FLOOR AREA FOR EXTINGUISHER: 11,250 SQ. FT. III III III III III FIRE EXTINGUISHER CABINET LAVATORIES 2.18 2 G. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER: IX. HANDICAPPED ACCESSIBILITY REQUIREMENTS 75 FT. 2-HR RATED WALL ® Name I Area (USF) WOMEN WATER CLOSETS 2.89 3 THIS PROJECT MEETS GEORGIA HANDICAP ACCESSIBILTY CODE 120-3-20. III I III III' III' Cr EXIT SIGNS LAVATORIES 2.18 2 A A MINIMUM 60" x 60" LANDING FOR DIRECTION CHANGE AT TOP OF RAMP TENANT - BUSINESS 3,730 sq. ft. 100 sq. ft. I Person 34 3-HR RATED WALL —' B. A MINIMUM 18" UNOBSTRUCTED MANEUVERING CLEARANCE ON PULL SIDE OF DOOR(S). TENANT — STORAGE 0 sq. ft. 300 sq. ft. I Person 0 C. A MINIMUM 12" UNOBSTRUCTED MANEUVERING CLEARANCE ON PUSH SIDE OF DOOR(S) IF DOOR HAS BOTH A CLOSER AND LATCH. )(C-7-Th( OCCUPANCIES COUNT D. RESTROOM ACCESS AND CLEARANCES PER APPLICABLE PROVISIONS OF GAC 1111 I Irl'III III III I II ! TENANT - ASSEMBLY 0 sq. ft 15 sq. ft. I Person 0 120-3-20-27 (WATER CLOSETS), -29 (URINALS), -30 (LAVATORIES), -34 (BATHROOMS). SMOKE PARTITION E. ACCESS AND CLEARANCES FOR SHOWER. Cxx TOTAL EGRESS AT DOORF. ACCESSIBLE COUNTER/TRANSACTION SURFACE NO MORE THAN 36"A.F.F. OTHER - BUSINESS 15,389 sq. ft. 100 sq. ft. / Person 154 G. A MINIMUM 36"WIDE REAR GRAB BAR. — — MAXIMUM DISTANCE OF TRAVEL OTHER - STORAGE 176 sq. ft. 300 sq. ft. / Person 1 H. A MINIMUM 42" LONG SIDE GRAB BAR. I. LEVER HARDWARE ON NEW OR RE-HUNG DOORS. OTHER - ASSEMBLY 0 sq. ft 15 sq. ft. I Person 0 J. NO KEY LOCKS ON EGRESS SIDE OF DOOR. — COMMON PATH OF TRAVEL BASE BUILDING & CORE "NOT IN SCOPE" 1ST FLOOR TOTAL 189 ---------------- DEAD END DISTANCE BUSINESS OCCUPANCY CEILING MOUNTED EXIT SIGN STORAGE OCCUPANCY H. EGRESS WIDTH PER EXIT (MINIMUM) - WALL MOUNTED EXIT SIGN CENTERED ONDOOR \ — \ \ — — — — — — — EXIT SEPARATION e//////� 1. LEVEL .2 (32" DIVIDED BY .2 - 160 PERSONS @ EA. EXITS) NFPA TABLE 7.3.3.1 EXIT m 0 07.01.19 ISSUED FOR PERMIT EXIT FINISH 2. STAIRS .3 (44" DIVIDED BY .3= 147 PERSONS @ EA. EXITS) rt CEILING NO: DATE: REMARKS: r/v/z/i/ ASSEMBLY OCCUPANCY FIRE STROBE I] REVISIONS: Exit Capacity Schedule- 1st Floor DRAWING TITLE: HANDLE ON FIRE THERMOSTAT EXTINGUISHER WHETHER I I NOTE-NO ACCESSORIES SHALL 1ST FLOOR LIFE SAFETY Exit No. 1 Stairway Capacity .3 1 Level Component 1 Capacity .2 1 Total Capacity INSIDE CABINETBE LOCATED IN THE AREA THAT HANGINGGON WALL IS 1 112"BELOW GRAB BARS& 17 ABOVE GRAB BARS P LAN EXIT#1 N/A N/A 68" 340 360 I "., w ❑-- — Q EXIT#2 NIA NIA 32" 16014 160 n 4 a n : m EXIT#3 N/A N/A 32" 160 160 a El —H _ § 5'- 1 p 1 ti---- PRo�ECT No. ISSUE DATE o Grand total: 3 680 28021.00 07.01.19 a) / FINISH m m \ T k A T Q FLOOR 1"'"' '� o DRAWN BY: CHECKED BY T HF AR c, NOTE.ALIGN ALL NEW DEVICES REGARDLESS OF LOCATION ON WALL NOTE CONTRACTOR SHALL VERIFY THAT ALL RESTROOM ACCESSORIES COMPLY WITH ADA REQUIREMENTS.WHERE ACCESSORIES DO NOT COMPLY CONTRACTOR TO ADJUST/MODIFY AS REQUIRED-DIMENSIONS ARE TO CONTROLS OR OPENING OF DEVICE. SHEET NUMBER: iS N 4 1 LIFE SAFETY PLAN LEGEND 3 1 GENERAL ADA CODES & MOUNTING HEIGHTS: 2 1 GENERAL ADA CODES & MOUNTING HEIGHTS: AO.21 I I I I 0 ,. , , ,•,., „, ., ASD SKY -,ist _._. .. ._ . /A ., . . . _ . . ,. _ .. , ____, _,// .... ..; . ,/ „--- ,/ � \ , \\ / ,/ „. . , ./ . / / f 7 f ,, . . . _., . __. //./.. //_.:.; ,.� . . / / , , , / , / / ../ , / ,,/ , / , ...7 / ... .... 7 , / 7 , / , , / ,,,,,, , / , , , / , //,................,..........*: -� /_ _=r� / _/ �, - / •, / / / ♦ �� / / / / !:. / / / / ✓' / , , \\ 920 SW 6th Avenue / ✓ / , ✓ ✓ / ✓ ✓ , ✓ / , ✓ / // ' z.„--- --r--`7._ , x / / / / / 4/ 12th Floor -7 .._ :11: :. :// . / ,„ ,,,i ,,, _ „. / / /,, , . , ,, / / / / , / , /ly ; / / Ali // / / ,/ ✓ / ,� /// 7i/i/i/i/i/iA/! www.asdsky.com \\\\\\ / / / /7/ , // illt-- . / / / , / 7- _ ,,, -...., .. , .. .,. . , V ilk o o .\\- 4111' \ ._.... -I / \Z / / /7 \el". _. / , ii / Y // // / // i.o. for \\\\ 1/ . . - --\--7\i„,..:. —- re" tA -- ' ----... --. 1 Aii//////////////, — , --"--) U ! —J E ......:r 144' -3„°I 11111 alool.-- / 1 -- — — EXIT S�t'ARAT10 ® 'Aim .. ..I i i 1 ,....._, 1 zzAiii.: .... ,..... - _ THE / , ; • . . .. . . rPARTNERS _ - I__ �- • .' - �� _ � r � - � r � rr GROUP Xlrl�; - i� r r + _ - • lir r _ r r I ( - / �r r /// 11850 SW 67TH AVE. il , . ...... 284' 01,2"_ ._ ,' . , _/ / Ilk SUITE 100 it- / / 4j:; . I 1 OR • 11111/7 ONAL / ✓ II/ • PORTLAND, LONGEST DIAD / — � Tr , - _�7 - - - ' ,� � /' ,' ✓'' ,' � � / � ' _ 97223 _ r • / - / / / .. /41 , ,,-",: Illill'-. / / / �- I . . // / ✓ ii i_, ✓ / / ✓ te /r 7 ____ _ , , , / .. , , DittA--- L-_ ----/----/----------- / // / / // // / / - ----- --"----"'----- ----- -------- , . _ . ..,,h. • • . , /// 1 /,,/_ /.,_ _ / / _.... . / /------/-✓ / / /; / may_ / ✓ / .____. • :,.,,,,,,, ., t_.• , _____, , / , : _ „ , . , , _e_ /r / 7 ,A,,„3 _/_. ,--/-, , ,., i___:_,,,/_:___, --, -,, / : 7 „. ,, 7 / / / / 7,./.._-_,-__/_ ././ / 7 // ././/./.„:// //...:/ //,/./7//, , •/, ,_ / ._____ . 7 / 7 . 1, 7 / 7 / 7 // / / ,_, 7 „..._, 4 r / / / / / / , / . / , ✓ ' / / / , / / % / / i / -; T / ✓' p /✓ / / /✓ -/_ /-' �/ / / /✓ / / ✓ / ,/ ✓ / ,/ -// / ,� ✓ / / / / / � // / / // „/.- i D ;OSEP`'A REMI.t�IG '�� 6526 ,�..j diSAN FILANCISCO. CA i� F J 1 2ND FLOOR - LIFE SAFETY PLAN 1 /8" = 1 '-0" This drawing is the property of Associated i Space Design, Inc. and is not to be reproduced or copied in whole or part. It is SYMBOL DESCRIPTION SYMBOL DESCRIPTION V. OCCUPANCY CLASSIFICATION 2ND FLOOR PLUMBING CALCULATIONS VIII. FIRE PROTECTION REQUIREMENTS not to be used on any other project and is to A. CLASSIFICATION TYPE: BUSINESS, GROUP B NFPA 6.1.1 [B OCCUPANCY: 214 OCCUPANTS (107 WOMEN/107 MEN)] A. MANUAL FIRE ALARM BOXES: MAX. 5 FT. FROM EACH EXIT be returned upon request. Scales as stated B. CONSTRUCTION AREA: 1ST FLOOR- 3,730 SQ. FT. /2ND FLOOR -21,322 SQ. FT. NFPA 7.3.1.2 B. VISIBLE ALARMS REQUIRED IN PUBLIC AREAS herein are for reference only as normal C. TENANT'S OCCUPANT LOAD: 1ST FLOOR- 3412ND FLOOR - 309 C. REFER TO MEP DOCUMENTS reproduction processes may alter the MIMDISTANCE TRAVELING D. FIRE EXTINGUISHER REQUIREMENTS PER: NFPA 10 (1-6)TABLE 3-2.1 (LIGHT HAZARD OCCUPANCY) accuracy of original drawings. I1-HR RATED WALL0 MEN REQ'D PROVIDED E. MAXIMUM FLOOR AREA PER UNIT OF A 3,004 SQ. FT. Associated Space Design, Inc. 2016 Occupant Load Schedule - 2nd Floor WC + URINALS 3.14 4 F. MAXIMUM FLOOR AREA FOR EXTINGUISHER: 11.250 SQ. FT. FEC FIRE EXTINGUISHER CABINET LAVATORIES 2.34 2 G. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER: 75 FT. r 2-HR RATED WALL 1 l Name 1 Area (USF) Load Factor SF/Person Area Occupant Load WOMEN IX. HANDICAPPED ACCESSIBILITY REQUIREMENTS WATER CLOSETS 3.14 3 THIS PROJECT MEETS GEORGIA HANDICAP ACCESSIBILTY CODE 120-3-20. III 1111 IIII III' Z, EXIT SIGNS LAVATORIES 2.34 2 A. A MINIMUM 60" x 60"LANDING FOR DIRECTION CHANGE AT TOP OF RAMP 3-HR RATED WALL TENANT - BUSINESS 17,002 sq. ft. 100 sq. ft. / Person 170 B. A MINIMUM 18" UNOBSTRUCTED MANEUVERING CLEARANCE ON PULL SIDE OF DOOR(S). C. A MINIMUM 12" UNOBSTRUCTED MANEUVERING CLEARANCE ON PUSH SIDE OF DOOR(S) IF DOOR HAS BOTH A CLOSER AND LATCH. © ROOM OCCUPANCIES COUNT 1TENANT - STORAGE 693 sq. ft. 300 sq. ft. I Person 3 D. RESTROOM ACCESS AND CLEARANCES PER APPLICABLE PROVISIONS OF GAC - 11111111111111111111111111 SMOKE PARTITION TENANT - ASSEMBLY 3,627 sq. ft. 15 sq. ft. / Person 242 120-3-20-27 (WATER CLOSETS), -29 (URINALS), -30 (LAVATORIES), -34 (BATHROOMS). E. ACCESS AND CLEARANCES FOR SHOWER, (200TOTAL EGRESS AT DOOR 1 F. ACCESSIBLE COUNTER/TRANSACTION SURFACE NO MORE THAN 36"A.F.F. 2ND FLOOR TOTAL 415 G. A MINIMUM 36"WIDE REAR GRAB BAR. - MAXIMUM DISTANCE OF TRAVEL H. A MINIMUM 42" LONG SIDE GRAB BAR. I. LEVER HARDWARE ON NEW OR RE-HUNG DOORS. - -- J. NO KEY LOCKS ON EGRESS SIDE OF DOOR. COMMON PATH OF TRAVEL BASE BUILDING & CORE "NOT IN SCOPE" -------- ------ DEAD END DISTANCE BUSINESS OCCUPANCY CEILING MOUNTED EXIT SIGN H. EGRESS WIDTH PER EXIT (MINIMUM) CENTERED ONDOOR — _ — — _ _ — EXIT SEPARATION STORAGE OCCUPANCY EXIT m9 \ j 0 07,01.19 ISSUED FOR PERMIT 1. LEVEL .2 (32" DIVIDED BY .2 = 160 PERSONS @ EA. EXITS) NFPA TABLE 7.3.3.1 WALL MOUNTED EXIT SIGN Cllr FINISH CEILING NO: DATE: REMARKS: 2. STAIRS .3 (44" DIVIDED BY .3= 147 PERSONS @ EA. EXITS) .. '1H ASSEMBLY OCCUPANCY FIRE STROBE - REVISIONS. HANDLE ON FIRE THERMOSTAT DRAWING TITLE: EXTINGUISHER WHETHER • NOTE NO ACCESSORIES SHALL 2ND FLOOR LIFE SAFETY INSIDE CABINET OR BE LOCATED IN THE AREA THAT HANGING ON WALL IS 1 112"BELOW GRAB BARS& Exit Capacity Schedule 2nd FloorBARS PLAN 12"ABOVE GRAS BARS_ \ II - I �.. z , ❑-_ - Q Floor No Exit No. Stairway Capacity .3 i Level Component Capacity .2 Total Capacity v 1 I ,tea a �- i_ FL-- LEVEL 02 EXIT#4 52" 173 33.5" 168 168 I I n® I _ 5 a' `' v g PROJECT NO.: ISSUE DATE: O LEVEL 02 EXIT#5 52" 173 33.5" 168 168 g Z $ 28021.00 07.01.19 0 FINISH �, - � �" Q � LEVEL 02 EXIT#6 54" 180 N/A N/A 180 / FLOOR I o DRAWN BY CHECKED BY: 1 Grand total: 3 516 NOTE ALIGN ALL NEW DEVICES REGARDLESS OF LOCATION ON WALL NOTE CONTRACTOR SHALL VERIFY THAT ALL RESTROOM ACCESSORIES COMPLY WITH ADA REQUIREMENTS.WHERE HF AR 0) ACCESSORIES DO NOT COMPLY CONTRACTOR TO ADJUST!MODIFY AS REQUIRED.DIMENSIONS ARE TO CONTROLS OR OPENING OF DEVICE SHEET NUMBER: 5 N 4 LIFE SAFETY PLAN LEGEND 3 GENERAL ADA CODES & MOUNTING HEIGHTS: 2 GENERAL ADA CODES & MOUNTING HEIGHTS: A� .22 _ 1 I ASD r ,(- , ----------, --------- - -;_______ _____ _ _ ____ ___________ _ _ . ____ ____. „. . , ,. . , _ . ,„,,„, , .. 10P CONF. \ \\\. , /7 ,41.0/z" ,,.. . ,.. \\\,,, . , . __- --- \ ' �j 103 101 �� �� 44 .-i /01417 ,�- -.. -.-----.-._-. RECEPTION q 0 OFFICE 113 OPEN OFFICE I 1 _____ __ 101 lick io., 113 "' 114 ..___.__. _____ _ .._._.________ __ ,4,,, \ • • , , r 1 +� '.. ®' • 103 © 0. ,1 31 920 SW 6th Avenue / - ��••i4/ vD OFFICE OFFICE ® \ O 117E 12th Floor i ■ �.__. ��' J�rI " • 112 ©® 116 Portland 0R 7 %sir © illir -0 !� +� 105 / ,� H,� 4. ` OFFICE .� \ T 678.491 .3773 a > ...��� ' ® 11s www.asdsky.com '� 105 4- igc Q® 1 %/� MEETING OFFICE ' /,. © 104 1048;11P--<__----- 1 A3111 \ OFFICE A6' R2 H,• 107 FEC\ 1151 . �, OFFICE cy96. ,i �1 A �' %'� ' �Q0 -0 • vv\ I JL.,....... �' r �� OFFICE •I ,4,c. .H.. . . :. \ 110 106 !1 , +V �` 109 Q®' 0 1 STORAGE 1 / 108 Rz H' \\\ 0 i�_-__.-� MAIL Immimmmim102 : w OFFICE ! • � �i, Q 110 / ��` PANTRY �9�'�i► I '08 1 0 � Q s' ©OFFICE _'�) i ____T 109 A / } \ �r �� S \______.., ' '%ice \ Otal .120 T H E F �,� ��I WOMEN'S • \ PARTNERS „% ,)I JAN. 'N--------- ,,I.- %� MEN'S 10 GROUP o b � � . it - - 1 - ' 11850 SW 67TH AVE. i ; SUITE 100 r PORTLAND, OR _____ i , 1 /„,. , /, . yt 97223 „:_., I ,,,, , „.„________,\. i ., . • ,/ ,, , ,__,.... \ ,,,..._ 111- .„ ____, , , \ , , _._ ..„ .,,, _____. , Lir I \ ,,_ ____ . .. . _., . . .. / / Z : .. .._ . .____,. ______ .. __. . . • _ .,_.,. .. .„. ._ ..... . . / ... • .. ... _. ...,,_. ____ .___ . ___.. .. . .____ . „... ______. ..._..,.____ .. ___ ., .._. .. 411_ `.,,,....... ,___ , .. rrrrs �rr�r i 1 1ST FLOOR - CONSTRUCTION PLAN 1/8" = 1 '-0" o5I '�A R1=n�L,�,c , 6526 a • GENERAL REQUIREMENTS: 1. ALL PARTITIONS SHALL BE AS FOLLOWS UNO: 1A3 +~ + SAN FHANCISCO. NO. CONSTRUCTION PLAN NOTE TYPE DESCRIPTION ; DI=TAIL NO.1 REMARKS . � ' CA gi 1.0 ANT ENSURE THORFIELD CONDITIONS,UGHLY FIELD IFY CONDITIONS PRIOR TO DIMENSIONS AND QUANTITIESMMENCING WORK/ARE CONSIDERED IN PRICING. 1.10.2 ALL NECESSARY WOOD BLOCKING SHLL BE FRE COORDINATE ETTING AND PLACEMENT OF THESE EILEM NTS ADND ENSURE TDHAT 1 PROVIDE FRT IN WALL BACKING FOR WALL MOUNTED MILLWORK OR EQUIPMENT. 2, DOORS SHALL BE LOCATED PER THE FOLOWING DIAGRAM UNO: ABOVE CEILING .tOF $ ' PREPARATION OF SHOP DRAWINGS AND SUBMITTALS LOCAL CODE/BUILDING REQUIREMENTS ARE MET. ' 2 PROVIDE IN WALL FLAT STRAP BACKING FOR WALL MOUNTED DISPLAY. 1A3 WALL TYPE 1A3: NON-RATED WALL W/3 5/8"MTL STUD TO 6"ABOVE CEILING, TWO-SIDED GWB 1/A7.01 3 PROVIDE 318" COPPER WATER LINE FOR TENANT SUPPLIED EQUIPMENT. 1 6 1A6 WALL TYPE 1A6: NON-RATED WALL W!6"MTL STUD TO 6"ABOVE CEILING, TWO-SIDED GWB 21A7.01 1.1 VERIFY PENETRATIONS THROUGH PARTITIONS (SUCH AS DUCTWORK, ETC) TO 1.10 3 BLOCKING MAY NOT BE COMPLETELY ILLUSTRATED ON DRAWING. GOOD 4 PROVIDE CODE REQUIRED EXIT SIGNAGE. REFER TO DA-REF SHEET FOR MORE CLR MIN GLASS ENSURE THAT ADEQUATE BRACING AND REINFORCEMENT ARE PROVIDED. CONSTRUCTION PRACTICE SHALL GOVERN. INFORMATION. , 1G3 WALL TYPE 1G3: INTERIOR GLAZING; WALL ABOVE TO STRUCTURE 3/A7.01 1.2 PROVIDE LABOR AND MATERIAL AS REQUIRED FOR WORK WHICH MAY NOT FALL 1.10.4 INTERNAL WOOD BLOCKING SHALL BE PROVIDED FOR STURDY ANCHORAGE AT 5 GC TO CONFIRM EXISTING DOOR HARDWARE MATCHES FUNCTION OF HARDWARE 2G3 WALL TYPE 2G3: INTERIOR GLAZING; WALL ABOVE TO 6"ABOVE CEILING 4/A7.01 TYPE NOTED; COORDINATE W/ARCHITECT IF IT DOES NOT,AS NEW DOOR& INTO JURISDICTION OF A SPECIFIC TRADE BUT IS REQUIRED FOR PROPER JOB INTERSECTIONS OF GLASS SIDELITES AND PARTITIONS AND ADJACENT DRYWALL HARDWARE MAY BE REQUIRED. I PULLSIDE I ONESIDED This drawing is the property of Associated EXECUTION AND COMPLETION OF CONSTRUCTION. CONSTRUCTION. 6 PROVIDE ROLL DOWN LOCKING SCREEN AT IT HELP DESK WINDOW. SPEC L J 103 WALL TYPE 103: NON RATED WALL W/3 518" MTL STUD TO STRUCTURE, ONE-SIDED GWB 5/A7.01 Space Design, Inc. and is not to be OVERHEAD DOORS, SURFACE-MOUNTED(INSIDE OF ROOM) COUNTER DOOR 652, 203 WALL TYPE 203: NON-RATED WALL W/3 518"MTL STUD TO 6"ABOVE CEILING, ONE-SIDED GWB 6/A7.01 reproduced or copied in whole or part. It is 1.3 DETERMINE AVAILABILITY OF ALL MATERIALS. ANY DELIVERY SCHEDULE THAT MAY ALUMINUM FINISH, LOCKING; PROVIDE BLOCK IN WALL AS REQUIRED; MOUNTED TO STRUCTURE not to be used on any other project and is to CAUSE COORDINATION PROBLEMS DURING THE CONSTRUCTION SHALL BE BROUGHT be returned upon request. Scales as stated ON INSIDE OF ROOM SIDE. 1S3 j WALL TYPE 153: NON-RATED WALL W/3 518" MTL STUD TO STRUCTURE,TWO-SIDED GWB& SAB 7/A7.01 TO THE ATTENTION OF THE ARCHITECT AS EARLY AS POSSIBLE, FOR REEVALUATION herein are for reference only as normal OF PRODUCT SPECIFICATION. 7 PROVIDE& INSTALL HUFCOR MOVEABLE GLASS PARTITION, GL FRAMELESS 1'_ 0:1. PUSH 156 1 WALL TYPE 156: NON-RATED WALL W/6"MTL STUD TO STRUCTURE, TWO-SIDED GWB& SAB 81A7.01 reproduction processes may alter the SERIES W/UNISPAN CONCEALED STRUCTURAL SUPPORT; WALL PANELS TO BE CLR. MIN LSIDE_I 4". accuracy of original drawings. GENERAL PARTITION NOTES STACKED AT SIDES,AS SHOWN; PROVIDE (2) SWING DOORS FOR EGRESS AT / • / // Associated Space Design, Inc. 2016 EACH END, AS SHOWN; ANY EXPOSED TRACK/HARDWARE TO BE MATTE BLACK, 1.4 REFER TO GENERAL PARTITION DETAILS FOR TYPICAL PARTITION INFORMATION. U.N.O.; COORDINATE EXACT SPECIFICATION W/HUFCOR &ARCHITECT; HUFCOR TO PROVIDE SHOP DRAWINGS FOR REVIEW/APPROVAL PRIOR TO ORDERING & 3. ALL PARTITIONS SHALL BE CENTERED ON EXISTING CURTAIN WALL 1.5 PARTITIONS LOCATED ABOVE DOORS SHALL BE OF SAME CONSTRUCTION AS THE FABRICATION. MULLION AND OFFSET FROM KNEE WALL PER THE FOLLOWING DIAGRAM ADJACENT PARTITION. . 8 PROVIDE LEVEL 5 DRYWALL FINISH IN PREPARATION FOR NEW FINISH MATERIAL. UNO: 9 GC TO CONFIRM IF NEW WALL FURRING IS REQUIRED FOR NEW AV CONNECTIONS 1.6 CAULK GAPS WHERE INTERSECTIONS OF CONSTRUCTION ELEMENTS ARE NOT & POWER. 1 ' EXISTING PARTITION TO REMAIN CRISP AND CONSISTENT. COORDINATE CAULKING & SEALING WITH SPECIFICATIONS 10 PROVIDE PLYWOOD ON (1)WALL IN THIS ROOM. • i OFFSET PARTITION - SHEET OR MANUAL, INSTALL PER MANUFACTURERS INSTRUCTIONS. WHERE REQUIRED " NEW PARTITION I 1.7 DOOR AND FRAMES SHALL BE SCRIBED TO THE FLOOR CONDITIONS. - - - - J AM DOOR# 1.8 VERIFY EXISTING WALL 1 DEMISING WALL 1 CORE WALL CONSTRUCTION AND MirHARDWARE SET --- - MATERIALS BEFORE INFILLING AND PATCHING ANY OPENING TO MEET REQUIRED FIRE DOOR & HARDWARE; REFER TO DOOR SCHEDULE ON SHEET A8.01 O DOOR&FRAME TYPE RATINGS- 1.9 DIMENSIONS: ' • - 1.9.1 DO NOT SCALE FROM THESE DRAWINGS. WRITTEN DIMENSIONS TAKE fr. EXISTING KNEE WALL PARTITION TYPE TAG PRECEDENCE OVER GRAPHIC PRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENCE EXISTING OVER PLAN DIMENSIONS. CURTAIN WALL INDICATES MILLWORK PROVIDED & INSTALLED BY G.C. SYSTEM 1.9.2 IMMEDIATELY NOTIFY ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES FOUND --- . BETWEEN THE SITE CONDITIONS AND THE DRAWINGS. NO DIMENSIONS SHALL BE Mil NOT IN SCOPE ALTERED WITHOUT THE APPROVAL OF THE ARCHITECT. 4. PROVIDE SMOOTH GYP. WALL FINISH AT ALL EXISTING WALLS TO REMAIN; 0 07.01.19 ISSUED FOR PERMIT TYPICAL THROUGHOUT, U.N.O. ® NO: DATE: REMARKS: 1.9.3 ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM A"BENCH MARK" OR OTHER FIRE EXTINGUISHER CABINET SOLID DOOR, FLAT TRIM, FULLY RECESSED, FIRE EXTINGUISHER- DRY CHEMICAL TYPE, CLASS B-C, SIZE 10 SIMILAR GUIDE ESTABLISHED PRIOR TO THE START OF CONSTRUCTION. HIGH POINTS, ALUM. CABINET, COLOR. WHITE REVISIONS: LOW POINTS, IRREGULARITIES IN FLOOR SLAB WHICH COULD AFFECT FABRICATION / DRAWING TITLE: INSTALLATION, WORK OF OTHER TRADES OR VENDORS SHALL BE BROUGHT TO THE FIRE EXTINGUISHER CABINET-SOLID DOOR, FLAT TRIM, SEMI-RECESSED, FIRE EXTINGUISHER- DRY CHEMICAL TYPE, CLASS B-C, SIZE 10 1ST FLOOR ATTENTION OF THE ARCHITECT. ALUM. CABINET, COLOR: WHITE CONSTRUCTION PLAN 1.10 MATERIALS: 2 1.10.1 INSTALL MOISTURE-RESISTANT GYPSUM BOARD AT AREAS EXPOSED TO Q MOISTURE INCLUDING, BUT NOT LIMITED TO, TOILETS, BREAKROOM COUNTERS AND PROJECT NO.: ISSUE DATE: co OTHER LOCATIONS NEAR WATER UNO. 28021.00 07.01.19 a DRAWN BY: CHECKED BY: T-- , -r SL AR a, SHEET NUMBER p CV 5 I GENERAL NOTES 4 1 CODED NOTES O CODED NOTE 3 I GENERAL PLAN TYPICALS 2 1 LEGEND Al .0 1 I i I . . _, . , \\,,,,, , .,.,, , \,,,\.„, ASD SKY -; ‘ , - --- -- - - - / \ � OFFICE 227 • ,,,I,G: MEETING 227 ©ROOM R2 H1 726 I 10 1:IS \ ,, OFFICE 226 GAMEROOM 228 Q®- 253 228 R2 H� • • .,,,. I . .S •, 920 SW 6th Avenue \oiir ®v o ,0. v� \ AM ;' t O Room 223' OFFICE 12th Floor OFFICE ®V ,� 0229E 229 225 R2 A 224 Portland, OR a® 265 ®1 A r ?1 T 678.491 .3773 ELEVATOR '� Qp PHONE LOBBY Aatiro• 1 �� • V1124. 223 ,0, © www.asdsky.cam 200 '�' ,�c,© MARKETING 230 , 40' \\\\\>,,\ -Q® OFFICE % STORAGE PHONE R2YA i+" © A.c 261 �� STOR 1 40' 252 230 I ®' MEETING RM / 0 4 � p. of �`©O I , ' )\ /(..2:;11V PHONE 261 A /// ,�c BREAKROOM >254 � � + � 222 - (.1,k 12PCO' Q® .• . 220 I © �S _ 252 I ,1 ti. ;$ , v R1 B1 ' • O 2� OPEN OFFICE ,0 -Q® 262 I • OFFICE . S 4 al . -400- o% , 7 , �r'> �' I ♦ OFFICE $4*60� % 0 F OPP. " . 'I' 221 �� 260 (Q/' 3 , 1 1 0 ' ©® '� `y O ; g` 1T SUITE 25 �i��/ • Q40 264 VC 25 OM N �� l 250 �, ® �'��/� v © 220 �� ' OFFICE �/ 1(6 n r• ` / ,/ 11 571VC ROOM '�' A ' 259 �,, , •_DO . • 91174' e 2/p6 a' 11 \,,E__1__„1.013 .�./ 218 263 .�a .ac• // O 4 7 ,6c ,,,,, A Ill 10 •/ 0 I OFFICE I©® R2 Hi 1 'Ory''`1 '/� �= \ _ \ inki 7 57 40 � "OSTORAGE •.rCOLLAR. OFFE 7-1,601C. ®� 217 �, . \r1� ,�c 267. •! 263 CO YOUPHINT '� • 251 40. , . ,� . QDAO 0 110 THE "W OUT A 256 OFE WOMEN'S.. �. ®� r26� , PARTNERS / .0. rco JANITOR 1 .. e ! EXEC. OFFICE 206 GROUP u OFFICE 40 . .. 203 II • 1 IA6.21 , t W+D MEN'S r Yr; � 205 1 �® ' OPEN OFFICE r 271 / a Q 256 �� ." � 10.1, ' '�EC. OFFICI= 205 4r, OFFICE 216 219 271 OFFICE ���,� Q��� O �� ©® 216 Q® "/// 11 .0 R2 H1 / 272 4P CONF. IMP 564• $ _ , /rA" � I� Q © %.„11c...,- � 204 \ �� ® OPP.0 �� OFFICE 11850 SW 67TH AVE. 268 ®• 273 �' , 2 43 0 4 0 OO lO g IA6 COFFEE �� 204 210 Q®Q® D® © 111,044%. //� 8P CONE , ►� N ��, �,� ©® SUITE 100 ®' 0 6 1A6.22 `� STOR. 294 EXEC. OFFICE EXEC. OFFICE > �f�` 20S 2 40 X10 ' ./ OFFICE �` PORTLAND, OR OFFICE '411110- 117 I MOTHER'S 2 ©� 296 297 r /� Ar. I 215 168 Q 4Q'�� ROOM ."'�ra © ,`�. • ©� V+ 211 / 214 97223 OFFICE 281 , HH �Q• Rz H1 h OFFICE } ,Z/X ,ac �' HCOATS �� R2 HJ 274 203 OPEN OFFICE ®® , . , A Q� O R2 H C97 293 •a• LIVING OROOM ' / 207 i • c OFFICE 270 ® - OFFICE 3 '�' ©® ' '�' 214 �� 269 Q® 280 � � � A � ----- --- "W w O y !� OPEN OFFICE 212 OFFICE ©® ) • OFFICE 280 COATS Via, , '�' 209 - 212 7 ,�, 1 ` ice ' / OFFICE ® =Q® "�"� •�e•c 293 T 4(.411A • 11 269 OFFICE OFFICE �„ EXEC. OFFICE 276 /T79 FICE1?°AO 279 iFil 2$3 283 289 289 R28H S f' < i c `�_. ,0. 207 ,. CO11 ' B ©® R2 H1 illil 213 ._-_ -__--„ . °11'lf.------' OPEN OFFICE , �' � O _.Y OFFICE //�� •G3 0 �82 284 288 OPP. `V' ...- ----(2,R2-6H8) 276 "`i�- Q " ,�. Q� t EXEC. OFFICE Dreirk ����� ,-_ OFFICEOFFICEr292 l �� Ef ��' OFFICE gin Q® 1111. 284 288 OPEN OFFICE 'a'278 /6 ,f Q .. --o 29D Y 0. COLLA;`r 4 OFFICE 2277 R2$H1 / ® 291 S 208 OFFICE OFFICE a® i-.0.,4 285 2874 BOARDROOM Q 202 OFFICE '9' , '� 291 COLLAR. A 0 286 = te) 1" - , JCiSEF"-'A REMtsNG r' 1 2ND FLOOR - CONSTRUCTION PLAN 118�! 1 -0" vro 6526 '7/ 0r • .AN F i t11NC15Ct�. • GENERAL REQUIREMENTS: 1 ALL PARTITIONS SHALL BE AS FOLLOWS UNO: I TYPE DESCRIPTION DETAIL NO.!REMARKS CA. ' 1.0 THOROUGHLY FIELD VERIFY CONDITIONS PRIOR TO COMMENCING WORK/ PRICING. 1.10.2 ALL NECESSARY WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED. NO. CONSTRUCTION PLAN NOTE ENSURE FIELD CONDITIONS, DIMENSIONS AND QUANTITIES ARE CONSIDERED IN COORDINATE SETTING AND PLACEMENT OF THESE ELEMENTS AND ENSURE THAT 1 PROVIDE FRT IN WALL BACKING FOR WALL MOUNTED MILLWORK OR EQUIPMENT. 2. DOORS SHALL BE LOCATED PER THE FOLOWING DIAGRAM UNO: ABOVE CEILING e017 olik PREPARATION OF SHOP DRAWINGS AND SUBMITTALS. LOCAL CODE 1 BUILDING REQUIREMENTS ARE MET. 1A3 WALL TYPE 1A3: NON-RATED WALL W/3 518" MTL STUD TO 6"ABOVE CEILING,TWO-SIDED GWB 1/A7.01 2 PROVIDE IN WALL FLAT STRAP BACKING FOR WALL MOUNTED DISPLAY. 1' -6" 1A6 WALL TYPE 1A6: NON-RATED WALL W/6"MTL STUD TO 6"ABOVE CEILING, TWO-SIDED GWB 121A7.01 1.1 VERIFY PENETRATIONS THROUGH PARTITIONS (SUCH AS DUCTWORK, ETC)TO 1.10.3 BLOCKING MAY NOT BE COMPLETELY ILLUSTRATED ON DRAWING. GOOD 3 PROVIDE 3/8" COPPER WATER LINE FOR TENANT SUPPLIED EQUIPMENT. /CLR MIN GLASS ENSURE THAT ADEQUATE BRACING AND REINFORCEMENT ARE PROVIDED. CONSTRUCTION PRACTICE SHALL GOVERN. 4 PROVIDE CODE REQUIRED EXIT SIGNAGE. REFER TO DA-REF SHEET FOR MORE ,, ,r- 1G3 1 G3 WALL TYPE 1 G3: INTERIOR GLAZING;WALL ABOVE TO STRUCTURE 3/A7.01 INFORMATION 2G3 WALL TYPE 2G3: INTERIOR GLAZING; WALL ABOVE TO 6"ABOVE CEILING 4/A7.01 1.2 PROVIDE LABOR AND MATERIAL AS REQUIRED FOR WORK WHICH MAY NOT FALL 1.10.4 INTERNAL WOOD BLOCKING SHALL BE PROVIDED FOR STURDY ANCHORAGE AT 5 GC TO CONFIRM EXISTING DOOR HARDWARE MATCHES FUNCTION OF HARDWARE INTO JURISDICTION OF A SPECIFIC TRADE BUT IS REQUIRED FOR PROPER JOB INTERSECTIONS OF GLASS SIDELITES AND PARTITIONS AND ADJACENT DRYWALL TYPE NOTED; COORDINATE W/ARCHITECT IF IT DOES NOT,AS NEW DOOR & PULL ONESIDED This drawing is the property of Associated EXECUTION AND COMPLETION OF CONSTRUCTION. CONSTRUCTION. I 103 WALL TYPE 103: NON-RATED WALL W/3 5/8" MTL STUD TO STRUCTURE, ONE-SIDED GWB 15/A7.01 Space Design, Inc. and is not to be HARDWARE MAY BE REQUIRED. SIDE 6 PROVIDE ROLL-DOWN LOCKING SCREEN AT IT HELP DESK WINDOW. SPEC: I 203 WALL TYPE 203: NON-RATED WALL W/3 518" MTL STUD TO 6"ABOVE CEILING, ONE-SIDED GWB 6/A7.01 reproduced or copied in whole or part. It is 1.3 DETERMINE AVAILABILITY OF ALL MATERIALS. ANY DELIVERY SCHEDULE THAT MAY OVERHEAD DOORS, SURFACE MOUNTED (INSIDE OF ROOM) COUNTER DOOR 652, TO STRUCTURE not to be used on any other project and is to CAUSE COORDINATION PROBLEMS DURING THE CONSTRUCTION SHALL BE BROUGHTbe returned upon request. Scales as stated ALUMINUM FINISH, LOCKING; PROVIDE BLOCK IN WALL AS REQUIRED; MOUNTED 1S3 WALL TYPE 153: NON-RATED WALL W/3 5/8" MTL STUD TO STRUCTURE, TWO-SIDED GWB & SAB 7/A7.01 TO THE ATTENTION OF THE ARCHITECT AS EARLY AS POSSIBLE, FOR REEVALUATION Iherein are for reference only as normal ON INSIDE OF ROOM SIDE. PUSH 1S6 WALL TYPE 156: NON-RATED WALL W16"MTL STUD TO STRUCTURE, TWO-SIDED GWB& SAB 81A7.01 OF PRODUCT SPECIFICATION. 1' - 0". 1reproduction processes may alter the 7 PROVIDE & INSTALL HUFCOR MOVEABLE GLASS PARTITION, GL FRAMELESS CLR. MIN SIDE GENERAL PARTITION NOTES: SERIES W/UNISPAN CONCEALED STRUCTURAL SUPPORT; WALL PANELS TO BE - accuracy of original drawings. STACKED AT SIDES,AS SHOWN; PROVIDE (2) SWING DOORS FOR EGRESS AT Associated Space Design, Inc. 2016 1.4 REFER TO GENERAL PARTITION DETAILS FOR TYPICAL PARTITION INFORMATION. EACH END,AS SHOWN; ANY EXPOSED TRACK/HARDWARE TO BE MATTE BLACK, U.N.O.; COORDINATE EXACT SPECIFICATION WI HUFCOR&ARCHITECT; HUFCOR 3. ALL PARTITIONS SHALL BE CENTERED ON EXISTING CURTAIN WALL 1.5 PARTITIONS LOCATED ABOVE DOORS SHALL BE OF SAME CONSTRUCTION AS THE TO PROVIDE SHOP DRAWINGS FOR REVIEW/APPROVAL PRIOR TO ORDERING & MULLION AND OFFSET FROM KNEE WALL PER THE FOLLOWING DIAGRAM - -_ ADJACENT PARTITION. FABRICATION. UNO: 8 PROVIDE LEVEL 5 DRYWALL FINISH IN PREPARATION FOR NEW FINISH MATERIAL. 1.6 CAULK GAPS WHERE INTERSECTIONS OF CONSTRUCTION ELEMENTS ARE NOT 9 GC TO CONFIRM IF NEW WALL FURRING IS REQUIRED FOR NEW AV CONNECTIONS11 iimmoww EXISTING PARTITION TO REMAIN CRISP AND CONSISTENT. COORDINATE CAULKING & SEALING WITH SPECIFICATIONS & POWER. i i OFFSET PARTITION - SHEET OR MANUAL, INSTALL PER MANUFACTURERS INSTRUCTIONS. 10 PROVIDE PLYWOOD ON (1)WALL IN THIS ROOM. 4,t' WHERE REQUIRED _ I ' NEW PARTITION 1.7 DOOR AND FRAMES SHALL BE SCRIBED TO THE FLOOR CONDITIONS. - - - .t a # DOOR# 1.8 VERIFY EXISTING WALL/DEMISING WALL/CORE WALL CONSTRUCTION AND o - - ---- MATERIALS BEFORE INFILLING AND PATCHING ANY OPENING TO MEET REQUIRED FIRE HARDWARE SET DOOR & HARDWARE; REFER TO DOOR SCHEDULE ON SHEET A8 01 - --' - N DOOR&FRAME TYPE RATINGS. -- --rir-- 1.9 DIMENSIONS: -� 'U' PARTITION TYPE TAG 1.9.1 DO NOT SCALE FROM THESE DRAWINGS. WRITTEN DIMENSIONS TAKE EXISTING KNEE WALL PRECEDENCE OVER GRAPHIC PRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENCE ' EXISTING OVER PLAN DIMENSIONS. CURTAIN WALL INDICATES MILLWORK PROVIDED & INSTALLED BY G.C. SYSTEM 1.9.2 IMMEDIATELY NOTIFY ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES FOUND - BETWEEN THE SITE CONDITIONS AND THE DRAWINGS. NO DIMENSIONS SHALL BE MI NOT IN SCOPE - 4. PROVIDE SMOOTH GYP. WALL FINISH AT ALL EXISTING WALLS TO REMAIN; 0 07.01.19 ISSUED FOR PERMIT ALTERED WITHOUT THE APPROVAL OF THE ARCHITECT. TYPICAL THROUGHOUT, U.N.O. NO: DATE: REMARKS: OP FIRE EXTINGUISHER CABINET SOLID DOOR, FLAT TRIM, FULLY RECESSED, FIRE EXTINGUISHER- DRY CHEMICAL TYPE, CLASS B-C, SIZE 10 1.9.3 ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM A"BENCH MARK" OR OTHER ALUM. CABINET, COLOR: WHITE REVISIONS: SIMILAR GUIDE ESTABLISHED PRIOR TO THE START OF CONSTRUCTION. HIGH POINTS, LOW POINTS, IRREGULARITIES IN FLOOR SLAB WHICH COULD AFFECT FABRICATION 1 DRAWING TITLE: INSTALLATION, WORK OF OTHER TRADES OR VENDORS SHALL BE BROUGHT TO THE FEC FIRE EXTINGUISHER CABINET- SOLID DOOR, FLAT TRIM, SEMI-RECESSED, FIRE EXTINGUISHER - DRY CHEMICAL TYPE, CLASS B-C, SIZE 10 2ND FLOOR ATTENTION OF THE ARCHITECT. ALUM. CABINET, COLOR: WHITE CONSTRUCTION PLAN 1.10 MATERIALS: Q 1.10.1 INSTALL MOISTURE-RESISTANT GYPSUM BOARD AT AREAS EXPOSED TO MOISTURE INCLUDING, BUT NOT LIMITED TO, TOILETS. BREAKROOM COUNTERS AND PROJECT NO.: ISSUE DATE: a OTHER LOCATIONS NEAR WATER UNO. 28021.00 07.01.19 ,- , DRAWN BY: CHECKED BY, ,- ,- SL AR a, E)SHEET NUMBER: p CV ,,, 5 GENERAL NOTES 4 CODED NOTES 1 CODED NOTE 3 IGENERAL PLAN TYPICALS 2 LEGEND Al .02 ,.._ O I I ... . , , 4. mi*\\ ASD SKY ... 6 I44$131 \ IV -� - � 310: •7.21 % /*OW OW) • �� , . -, z 0 -all .A., 111.0030W-.0 _...- 1 . 4,_----...,-,..„, :::40 oi_EL,_\ -4,1110tro,,,K.,„, ' 4, 2 k 7 "� . 2' , 4 .4 -:''' --"/` '-- ''' .' .:'*WWOWIWW":''-‘- i r� Al , .' 0.‘A,*Ott\1 7.21 ' �- •��• :. 0� ~Np �is � . V ���0 . P.W\ - - 1 ':.'.._<.':.'-::.:.- --•.%4194P.' "--',;..,, -•:-.;) TOO ••- Z.. 070\ lAl. iii , mi . ++:�iii®i .a,. 0 T - -• -.' - -**S.';Er* 1 01 - .-0.. A ) 1,,,,, --,,- .1111. ill WO Ofilegattl `-.`'� a 1,��00**II all**4141°‘‘SI I IPWTOWW.1� 111100 �++++++.+�+. ..+t�+� F - 1.c • O .V t.i.014:044:40°00#°\ Ow wwv A vegkloow‘o, ®�01 ' 1a'-0 c 'i st. 'i+i+i iii t� i_ .3B , . PV.\*At....***4 \ 920 SW 6th Avenue .. ...___� t Q a 12th Floor ,-iia,+.+Q.00+.+i+Dip+. f 3B • 10'-0" A • `.: -_ ..' yip+O+pp+i+i;0�':� .:,, -:.- .: _ +, .. 410*****41 ""ma""""r- �-- ;� "iik, ; n - . iii#44,_ .::.'. �' ' 5 . 10' Q" A �� ►� 'c- +..+.... Portaand, OR y. *WTI ti .. .. ++�e�' ! . 7.21 10' 0......• ;�� . , 1. �NT'`. I A , `'\ T 678.491 .3773 sn F.6 *Orrt01._...... IE ij:1 iog 0friO **IP*00040.01 4i ® *4 :. ----''' Ni: www.asdsky.com 7.21 ._:.�.�ealliErik4 • • 10'-0 A 0 II .. ..1001%11 0 *11001 � %lb , 111 10'-0" A is, � 1111 1. \. -....=L_ WA-D . 10-0" A . . �•. IN)1000 1111" '-0" I A r- *•0.0 c �0 •F0 AS, ,,,:_ -'-' .____ 14, . . \ ® / ... F60 $4*0 , ir- .' ,. , , (10'-0" A ) .� .�1111 . m� 1• a•1 • • l 11111.11110' 1111111111111\1111111\11W .�11.5 •• . • ;/ ,11 c::\ { 0 A .. . . 10'-0" A "/ /lc \' ..d ird kW 0.1 0 ; .. ....•.. . ..:- ,, • ikiliWillOPP*11 10' 0" A ---- \i _ / \ 10 � �` THE � 1a'-a" A ' PARTNERS GROUP 4/ \' =-1.17- - 11850 SW 67TH AVE. • / SUITE 100 r PORTLAND, OR -1 - 97223 i • . 3 410/ I . f , I' ------ ____ _ -.__ _._. 1 1ST FLOOR 1/8" = I-0" v ;05EP`I A REML1 � �� NO. REFLECTED CEILING PLAN NOTE TYPE INDICATION CEILING DESCRIPTION �� ' 6526 y 2.0 GENERAL REQUIREMENTS PRICE AS ADD ALTERNATE: TO SPRAY UNDERSIDE OF METAL ;AN FititNCISCO. 2.2 COORDINATION ACCESS: Cn 1 COORDINATE EXACT LOCATION OF PROJECTORS, PROJECTOR SCREENS & DECKING W/K13 ACOUSTICAL TREATMENT IN THIS ROOM/AREA A 2'X 2' SUSPENDED ACOUSTICAL SPEC: USG MARS 85135 2X2 FLB EDGE TILE W/OXT 9116" GRID 2.0.1 REFER TO CONSTRUCTION PLAN AND SPECIFICATIONS FOR TYPICAL, GENERAL SPEAKERS WITH AV DESIGNER TILE & GRID CEILING REQUIREMENTS, INCLUDING SUBMITTAL REQUIREMENTS. 2.2.1 ACCESS SHALL BE PROVIDED AS REQUIRED FOR INSTALLATION AND 2 LIGHT FIXTURES TO BE SWITCHED IN THIS ROOM, NOT ON OCCUPANCY SENSOR. I ' j, MAINTENANCE OF MECHANICAL, ELECTRICAL, DATA AND OTHER ELEMENTS A2-2 PRICE AS ADD ALTERNATE: TO PROVIDE DUAL-ROLLER MANUAL 2.0.2 DURING THE BIDDING PROCESS, VERIFY THAT ALL SPECIFIED LIGHT FIXTURES WITHIN CEILING PLENUM AND AS REQUIRED BY CODE. TYPES, SIZES AND 3 FULLY RECESSED PROJECTION SCREEN; MUD INTO DRYWALL CEILING. -- MECHOSHADES; (1) BLACKOUT SHADE, COLOR TBD; (1) 5% OPEN 2'X 4' SUSPENDED ACOUSTICAL SPEC: USG MARS 85/35 2X4 FLB EDGE TILE W/DXT 9/16" GRID CAN BE MANUFACTURED, SHIPPED, DELIVERED AND INSTALLED WITHIN THE LOCATIONS OF ACCESS AREAS SHALL BE REVIEWED AND APPROVED BY THE COORDINATE DETAIL WITH AV VENDOR &ARCHITECT. SHADE, COLOR TBD. MECHOSHADE HOUSING TO BE RECESSED IN B TILE & GRID CEILING G PROJECT SCHEDULE. ANY FIXTURES WHICH CANNOT MEET THE SCHEDULE SHALL BASE BUILDING ENGINEER. 4 RECESSED PROJECTOR ON MOTORIZED LIFT MOUNT; BOTTOM OF PROJECT LIFT DRYWALL CEILING. I ' I HAVE A SUBSTITUTE WHICH CAN MEET THE SCHEDULE REQUIREMENTS SUBMITTED TO BE APPLIED WITH ACT CEILING TILE AND SIT FLUSH IN CEILING. COORDINATE TO THE ARCHITECT FOR REVIEW- SEE SPECIFICATIONS. 2.2.2 LOCATIONS FOR SPECIAL ACCESS DOORS AND HATCHES SHALL BE DETAIL WITH AV VENDOR&ARCHITECT. A2-3 ) PRICE AS ADD ALTERNATE: TO REPLACE EXISTING SCONCES WI COORDINATED WITH ALL TRADES AND APPROVED BY THE ARCHITECT. ANY 5 START W/FULL CEILING TILE HERE. NEW; $800/FIXTURE ALLOWANCE . ., 112" GYPSUM BOARD ON DRYWALL SUSPENSION SYSTEM. PAINT PT-1 FLAT FINISH U.N.O. REFER TO This drawing is the property of Associated 2.1 GENERAL CEILING NOTES: ITEMS LOCATED ABOVE GYP BD CEILINGS WHICH REQUIRE REGULAR ACCESS C •._ GYPSUM BOARD CEILING FINISH SCHEDULE Space Design, Inc. and is not to be SHALL BE RELOCATED TO AN AREA IDENTIFIED BY THE ARCHITECT TO reproduced or copied in whole or pad. It is 2.1.1 REFER TO GENERAL REFLECTED CEILING STANDARDS FOR TYPICAL PREVENT THE NEED FOR ACCESS PANELS. not to be used on any other project and is to INFORMATION. OPEN TO EXISTING STRUCTURE be returned upon request. Scales as stated 2.2.3 PROVIDE ACOUSTICALLY-LINED "Z" BOOTS AT ALL TRANSFER DUCTS AND D a ,'.•4 EXISTING EXPOSED CEILING PAINT OUT PT-1; PAINT ALL EXPOSED MEP ITEMS PT 1. herein are for reference only as normal 2.1.2 INSPECTIONS AS REQUIRED BY LOCAL AUTHORITIES SHALL BE COMPLETED WHERE RETURN VENTILATION IS REQUIRED AT FULL-HEIGHT PARTITIONS. reproduction processes may alter the PRIOR TO CLOSING OF CEILING. - --- - - - - - accuracy of original drawings. 2.2.4 COORDINATE WORK BETWEEN THE ENGINEERING AND THE 2.1.3 THE FINISHED CEILING PLANE SHALL BE LEVEL.TRUE, AND SQUARE. ALL ARCHITECTURAL DRAWINGS: E SUSPENDED BAFFLES SEE DETAIL 9/A7,21 Associated Space Design, Inc. 2016 LIGHTS, SPRINKLER HEADS, HVAC AND OTHER ELEMENTS INCORPORATED IN ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN WITH RESPECT SPEC: PLASTIC LAMINTE FINISH - PL-2 CEILING CONSTRUCTION SHALL BE ALIGNED WITH CEILING PLANE. TO AESTHETIC CONSIDERATIONS, QUANTITY, LOCATIONS FOR FIXTURES, DEVICES ETC. VERIFY QUANTITIES (NEW OR EXISTING) INDICATED ON PLANS. • • SUSPENDED TECTUM PANELS SEE DETAIL 101A7.21 2.1.4 FASCIAS/ SOFFITS SHALL BE LEVEL AND TRUE, FREE OF SURFACE MECHANICAL AND ELECTRICAL CEILING PLAN SHALL GOVERN WITH RESPECT 6 CODED NOTES 5 ALTERNATES NOTES A2 X F SPEC: ARMSTRONG TECTUM SHAPES & CLOUDS COLOR TBD DISTORTION AND DIMENSIONED ACCORDING TO DETAILS SHOWN. TO FUNCTIONAL CONSIDERATIONS AND OVERALL SCOPE OF WORK. O CODED NOTE 2.1.5 ELECTRICAL, MECHANICAL AND PLUMBING ELEMENTS SHALL NOT COME IN 2.3 LAMPING/SWITCHING: TYPE DESCRIPTION MANUFACTURER MODEL COMMENTS i���.�.�•�.�.�. pD .•.•+++�t►�• .�. �.�.� t'i SUSPENDED FELT PANELS SEE DETAIL 11/A7.21 CONTACT WITH CEILING CONSTRUCTION EXCEPT AS REQUIRED BY PENETRATIONS. F.1 LED LINEAR- SUSPENDED ALW SUPERPLANE 2.5- LENGTHS VARY; FIXTURES & LENSES TO HAVE SEAMLESS 'T', 'L''X' G +++++++++� SPEC: FILZ FELT AKUSTIKA 10 W/WRAPPED EDGE- COLOR TBD 2.3.1 WHEN ENGINEERING DOCUMENTS DO NOT EXIST: SP2.5S-S**-MED-80-3500-0/10V/S-CR/S-N-BK-UNV CONNECTIONS. :• •�.���� 2.1.6 DIMENSIONS: ALL DOWNLIGHTS (INCANDESCENT OR LOW VOLTAGE) SHALL BE ON A SINGLE F.2 RECESSED LED LINEAR ALW SUPERPLANE 2.5 RECESSED- LENGTHS VARY A. DO NOT SCALE FROM THESE DRAWINGS. WRITTEN DIMENSIONS TAKE DIMMER RESPECTIVELY. SP2.5R/F-TGRID19/16-S**-MED-80-3500-0110VIS-C RIS-N-WH-UNV CEILING � CEILING HEIGHT FROM A.F.F. PRECEDENCE OVER GRAPHIC PRESENTATION. DETAIL DIMENSIONS TAKE ALL WALL WASHERS SHALL BE ON DIMMERS PER ARCHITECT'S INSTRUCTION. , 3 ICEILING TYPE LEGEND ( �-� ) PRECEDENCE OVER PLAN DIMENSIONS. ALL OFFICES SHALL BE SWITCHED INDEPENDENTLY. F.3A LED DOWNLIGHT-ACT CEILING FOCALPOINT ID+4.5" ROUND SYMBOL VERIFY ALL EXISTING CONDITION) B. NOTIFY ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES. ANY CONDITIONS ALL CORRIDORS SHALL BE ON DUAL-TECHNOLOGY MOTION SENSORS. FLC4D-R0-1500L-277-L11-T-LC4-RD-1500L-35K-DN-CD-WP CEILING TYPE REQUIRING MODIFICATION TO THE DIMENSIONS SHALL BE BROUGHT TO THE ALL INTERIOR ENCLOSED ROOMS SHALL BE ON DUAL-TECHNOLOGY MOTION F.3B LED DOWNLIGHT-GWB FOCALPOINT ID+4.5" ROUND- 1. ALL CEILINGS SHALL BE 10'-0"AFF TYPE 'A', UNO ATTENTION OF THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO SENSORS. CEILING FLC4D-RT-1500L-277-L11-T-LC4-RT-1500L-35K-DN-WH PROCEEDING. F.4 LED PENDANT DOWNLIGHT V2 LIGHTING CORE 200 LX-C2LP-DVD-20833540-T1 WH 2. SPRINKLER HEADS SHALL BE INSTALLED AS FOLLOWS: C. LIGHTS SHOWN IN 2x2 CEILING TILES SHALL BE CENTERED UNO. F-5 BREAKROOM DECORATIVE ROLL AND HILL AGNES CHANDELIER- 14 LIGHTS GWB CEILING - FLUSH CONCEALED TYPE CENTERED ON LIGHT D. COORDINATE THE LOCATION OF LIGHT FIXTURES OR DEVICES NOT SHOWN FIXTURE 2X2 CEILING - SEMI RECESSED, WHITE TRIMMED DIMENSIONALLY WITH THE ARCHITECT PRIOR TO INSTALLATION. F-6 LED 2X4 FIXTURE FOCALPOINT EQUATION 2 - FEQ2-24-AC-XX-35K-1C-UNV-LD1-G2-WH F.7 WALL SCONCE OPTIC ARTS ARM.125-ARM-125-MB-35-CW1-004-SR-COXX-XX-010-14 I 3. CENTER CEILING GRID IN ALL ROOMS/AREAS: U.N.O. -- 2.1.7 PROVIDE SEMI-RIGID SOUND ATTENUATION BLANKETS WHERE INDICATED ON 0 07.01.19 ISSUED FOR PERMIT DETAILS OR PLAN. F.8A BULB PENDANT W/BUZZI BUZZ/ /FIXTURE PLEAT EDEL - BLACK ICE- MEDIUM/ FIXTURE SPEC: - PD3106 COORD. MOUNTING HEIGHTS W/ARCHITECT 4. NO SUBSTITUTIONS WILL BE ACCEPTED FOR ANY ACCENT LIGHT FIXTURES PLEAT EDEL SPEC; KUZCO No: DATE: REMARKS: 2.1.8 VERIFY WITH BUILDING MANAGEMENT IF ENERGY MANAGEMENT SYSTEM IS IN F.BB BULB PENDANT WI BUZZ/ BUZZ/ f FIXTURE PLEAT EDEL- BLACK ICE- LARGE I FIXTURE SPEC - PD3106 COORD. MOUNTING HEIGHTS WI ARCHITECT 5. COORDINATE LOCATION OF DIFFUSERS, STROBES, SPRINKLERS, ETC. IN DRYWALL CEILING WITH ARCHITECT PRIOR TO INSTALLATION. REVISIONS: USE AND IF TENANT SYSTEMS ARE REQUIRED TO BE TIED INTO SAID MANAGEMENT PLEAT EDEL SPEC; KUZCO SYSTEM. THIS WORK SHALL BE PART OF THE OVERALL CONTRACT IF REQUIRED. F.9 IT SUITE DECORATIVE FIXTURE HIGHTOWER CARAVAGGIO MEDIUM- CAR200- BLACK 6. ALL SWITCHES/SWITCHING FOR AV EQUIPMENT SHALL BE GANGED NEXT TO THE LIGHTING SWITCHES. DRAWING TITLE F.10 UNDER CABINET TAPE LUMINII KENDO S HIGH EFFICIENCY- KS-**-35K-SO-F-FC-SA-B LENGTHS VARY 1ST FLOOR REFLECTED LIGHTING 7. GC RESPONSIBLE FOR COORDINATING SPRINKLER LAYOUT WITH AV EQUIPMENT LOCATIONS. CEILING PLAN E11 RECESSED PERIMETER LED ALW SUPERPLANE 2.5 RECESSED PERIMETER MOUNT- VERIFY LENGTH IN FIELD 8. LOCATION OF ACCESS PANELS TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. ACCESS PANELS IN GWB CEILINGS TO BE: LINEAR HYWGRMUD-S**-MED-90-3500K-3500K -WH-WHQ F.12 GAMEROOM DECORATIVE SONNEMAN ATELIER 8-LIGHT PENDANT COORD. MOUNTING HEIGHT W/ARCHITECT MANUFACTURER. WILLIAMS BROTHERS (OR EQUAL) F'fiUJEC�N(}: ISSUE UAIE: N FFIXTURE SERIES: WB RDW 410 SERIES- RECESSED FOR DRYWALL ACCESS DOOR FACE 28021.00 07.01.19 ,- 9. GYP CEILINGS & GYP CEILINGS W/ FELT TO RECEIVE MUD-IN LINEAR DIFFUSERS. COORDINATE W/ARCHITECT FOR LOCATIONS & PROFILES. DRAWN BY: CHECKED BY: r N- 1 0. - 10. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS & LOCATIONS, SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE HF AR a, CENTER OF CEILING TILES & SOFFITS, TYP. U.O.N.; INSTALLER SHALL COORDINATE W/OTHER TRADES TO AVOID CONFLICTS W/HEAD LOCATIONS & PIPE RUNS. SHEET NUMBER: T 0 (N 7 I GENERAL NOTES 4 1 FIXTURE SCHEDULE 2 I GENERAL TYPICALS A2 .O1 1 I .... /4./4:111 ,\ .♦ ♦ ASD SKY 4., \\\,\\ 1a-0" A ` A2-1 14.A.Z*. • „ 0 \ '14404 -* 412110 ,' c° Aillfritilitira0V te 4123 <IA ZW" 4:W1.\ In 11‘0 ___---- % #$W0704441*1 k AANTOA." ,.46411111010.‘\ OW 124%$M0a*vAO.ttOote ,---------__ __,._,, , o* Ai * \\ 1. A . 1 'a ,0. -o (10 -D A ) VP"AWP- sit. • 10; _ illok'r ilik I. j� , 04?w‘lrifr444114A. * „ . • % • 110111V111P*1•111111111111k 10'-0" A :11.1114K r r ; „. , ,, , vr. idt---" EallikA . ! .. . / . : .. . . •: ..,..: , . , . ., 1 ,\ .01 iik*gr 1/ W*WW4tit '' \ - r .. 7.2t ' 920 SW 6th Avenue /41244/ , ,14. ` • \ F.1 �m�•� �� = 4.0*11001 OWOO \ 12th Floor __,--„__ : ,.. ., . .4 1a-o" 2 ,. • • ®�' , ' •' �• ® � Portland OR r� -� tf \Imil • �' ® RFs • 10 -0" A . .' ®j .� 10 -Q A ) \ T 678.491 .3773 . ® • �W Ali► .�-�1 ' ��� • , ®\ ® www,asdsky,Com itts**/ t / r. iL. ' / '-- 'i - *,)'• .A. 1111b•- '-. - . 11A0101111 111/901. 101-0" A )11.101W 110 OA/ • 1110001K 14410% ilik la-ir A,) 1111-*.t.010*,° 1/' GEL* UE1/ 1a-0" A _�" . • jowl: 0 -��� F.6 �� • 1• #0 111 .•0 'V♦ ` °12134V4\ (10' 0" I AS �0 - I F.6 ��m__,_ A -{�� � � �W0111111111ylit� 11110"11141011111150 �S '. �. , m •7.21 �- "•. �� -� 7p� °' I t {10'-0" A lika � • �� ' ® q 4, ` 10 0 C ) io., .:_ .,, -,,,,„ illir 111.1211 \ . \ A ) Ill iii, olow#1110„,:wirEao. ,,, ,1111.11--6-3111rw-11**240w . 4 1:9 -4" ..: . -_____ at .1 4 '1'.. 1 F.63.iiiirrws,.ma sertilti i it: Ito*,,.. .' . 111‘ 10'-0" AO . 0* ] ' , 0 - - 11 Po" -*OM* 0.%V.4V4 , -/°tV %Ikea°. 1 \ 0010k 1 oi e: - 0014110‘**‘10. . ilf II Fli / / 4=i-.' , 111 MO&111 I II II 601 raw 11 .00134 ,..,,.,:. .., NP,' ii -, , --i-------- - _____'--.)6 1 - _., . rn 4W1 / . \_6-o F.2041 1 110.A.\\ 4- 1110** ��: '�"" F.6 ��� • .1111 \ ,0•01.0 .0‘..W.‘00W0.‘0•040;*Sialyttr‘1% �1110 OW *la0 aiirt-: !Jir.* .:.,7.:„rP • AVILV\ tr 1' �� \ ' 1 a-0" A • 3 , , ' 7 1 ify-0" A 1114113,01p.-011 o 1 L./ • • e. F.3A F.3A o F.3A �, r �*. .:. .' i . I 1 .10' . WI 0 ��•• 0 ®� ®� • ,� � 1a-0" A 1 F�� . 1 �C �. 0�� / s • THE I -I 1 11, LI ,_ • (------- _ � I�lir* -� - - - - I • 1„"________ � - �'� � r �•.. vt** *wo% ,0,.o. � �� -:�:.. �_.., ,.. !� ® �. �� ��. �• �,� � PARTNERS *OW tka#*I *11-0 0 ..- -- , . ,:_... . _ :..•.•. .r._.• ._ . . . , ._, ••.*•••,/r / • GROUP . F 00. 0" A -1-.) I F.6 I • . , �• ®, .ili 1D`-0" A 11111111101• • A.w. Ott,„0 .1%*04w0wit•r. ‘.,wilkso.w.***,w-,4*_,....0-*-.0...0--.0..,wow .- . �,,SV (,a'-Q" I Ate= g; :� . 0‘.*-:y. ®' •1. ��� 101 __10-41100.440 AO. •. o 10 -0" , (1a 0 A ) 101-0" I A ) 16-0 >/ • 1'.' ,� AAW.`� i " ,.... o �� 12 liklialk 1,41?..L lit��� :� 11859 SW 67TH AVE. F.3AF,3A_ icilo. � LI ,... �::: .�• {1aa" A _� ITE 1 1 y ,, a � ... •...+. �� 1116411147.111114.a7.2, : _ �1®1 � �� �• su o0 / i F.1 '. .-1,4'------f_ -ON �. , " , .00, f ..- +.+.o� ,gli ;f4 - � `ilik i PORTLAND OR �_��•0" !• . + © o I '© �'��+..+1 ' ...4 1 �+ate♦ _ --11-1,,-.111110--31111111610111' • •:**01W. 111 - /irtilia,/ I F.3A-... �F� I F.2 �F.2 I �F� I F.2 �F.2 I +++++�• .,��... . - (,0 -a A ) WiTallIP �/ 97223 / -. ---0 •_� •� PO's I l ,. . l I . 1 1_ . J 1 S • 171 1•101t**4.1140,10j1- (1a-0" A ) :':I Aa*- '� . .. 1� 8� s" ..�.11713111" , �� lF.3A_F.3A-. O �e 1 ��� r . . ®AalliS00wW*.. / ?'_ ,. , , -/111/1 .. Itit 721ill .� 1 �` • , ,,wirisiI�. _____:,_ , .,,,, ' I, jr.._ Abia,_0" IIII 11 12 _. • I .•. �, 2. 01,10.-10111110r0.10*W*.t'."-f01•00A701-� ... .:-..1 •• 0 0 �. �� a , }� 1 A 10' A TYP. F.1 • .1 \\ /** •,N i L. �� . • 7.21 �� 1�L_ a'0 I D I 12 �� _ F.3A I Q. .'. 1_ .'� '.. . _. tri...._ / . .101011011i.- 7.21 i i 1 • � '':: ( ® 'li - - . - - e,c)P.-:- 4. � �,a-0 A ) 11.04 . } ‘<7n1" 12 0 (1D' 0" A .: 1 OMR 511 0 . arW*/ -1,--.. ...._÷ _ t. . .. W*&WI Z'.,o ' , tibbb • •. 4•'1?" , ,� 1a Q" A 1a Q" A • ��p_C� �' F.2 I ..;....,..iT: 0 ' �• ► * , ...ti..:,..-:''':..- ,•.IA. -• ••• ®s01v - ,,:- ;:±,:''' ' •01104011$0 -� 11441111011111110 .,_,---- 11104111,11L10 -.4111111111X11111111 yAgirlir** (101-0" A 1 1 1 I0 L., .. .. -. .....-.... .. - '.- ' , .1„ 120._11, ,L.w ow, -__,„_____ '- ...-.- kW"-)41 ° - ' 1. 1'r- ;'-'-- 1 -1 . . :- - , _ .. . .. :: AMI + (1a-0" A ) (1a-0" I A � RIM, © II_ 1Y-0" A ,/ ,:- b NI '- - � 010 -•, .I r ''IZI1. WII .T .: 11,W WigagW ,;_iyiti --------- a_111110':.:.` ::-.4_ �� " 4'-0" b'-,;" I (.,•/2 -0"_ ® F.2 1 :I j 6 -0" l .2 11111121110 ��` _. � - - _-• ,mac ,",,,. . \_ 1 P ISI i I I 1 I Ilii I1 ,. L _ . ; :. (1a Q" i_•c. ._.-..----.__.._._..---1-.--_-.. _ -..--1111 . �F3B ' - F.3B \.'7.: 2. F.3B '. - :1 - , A2-2 -n o 1 1 2ND FLOOR - RCP 1 /8" = 1 '-o" ,OSEPH A REMLING ' TYPE INDICATION CEILING DESCRIPTION . 6526 '-'1 NO. REFLECTED CEILING PLAN NOTE 2.0 GENERAL REQUIREMENTS IF- , ' SAN FRANCISCO . 2.2 COORDINATION ACCESS: -,\ PRICE AS ADD ALTERNATE: TO SPRAY UNDERSIDE OF METAL CA 01, REFER TO CONSTRUCTION PLAN AND SPECIFICATIONS FOR TYPICAL, GENERAL 1 COORDINATE EXACT LOCATION OF PROJECTORS, PROJECTOR SCREENS & DECKING W/ K13 ACOUSTICAL TREATMENT IN THIS ROOM/AREA A 2' X 2' SUSPENDED ACOUSTICAL SPEC: USG MARS 85/35 2X2 FLB EDGE TILE W/ DXT 9116" GRID REQUIREMENTS, INCLUDING SUBMITTAL REQUIREMENTS. 2.2.1 ACCESS SHALL BE PROVIDED AS REQUIRED FOR INSTALLATION AND SPEAKERS WITH AV DESIGNER I i TILE &GRID CEILING k'OF MAINTENANCE OF MECHANICAL, ELECTRICAL, DATA AND OTHER ELEMENTS 2 LIGHT FIXTURES TO BE SWITCHED IN THIS ROOM, NOT ON OCCUPANCY SENSOR. 'i42_2 ' PRICE AS ADD ALTERNATE: TO PROVIDE DUAL ROLLER MANUAL 2.0.2 DURING THE BIDDING PROCESS, VERIFY THAT ALL SPECIFIED LIGHT FIXTURES WITHIN CEILING PLENUM AND AS REQUIRED BY CODE. TYPES, SIZES AND 3 FULLY RECESSED PROJECTION SCREEN; MUD INTO DRYWALL CEILING. " - MECHOSHADES; (1) BLACKOUT SHADE, COLOR TBD; (1) 5% OPEN 2' X 4' SUSPENDED ACOUSTICAL SPEC: USG MARS 85/35 2X4 FLB EDGE TILE W/ DXT 9/16" GRID CAN BE MANUFACTURED, SHIPPED, DELIVERED AND INSTALLED WITHIN THE LOCATIONS OF ACCESS AREAS SHALL BE REVIEWED AND APPROVED BY THE COORDINATE DETAIL WITH AV VENDOR &ARCHITECT. SHADE, COLOR TBD. MECHOSHADE HOUSING TO BE RECESSED IN B TILE & GRID CEILING PROJECT SCHEDULE. ANY FIXTURES WHICH CANNOT MEET THE SCHEDULE SHALL BASE BUILDING ENGINEER. 4 RECESSED PROJECTOR ON MOTORIZED LIFT MOUNT; BOTTOM OF PROJECT LIFT DRYWALL CEILING. 1 HAVE A SUBSTITUTE WHICH CAN MEET THE SCHEDULE REQUIREMENTS SUBMITTED TO BE APPLIED WITH ACT CEILING TILE AND SIT FLUSH IN CEILING. COORDINATE TO THE ARCHITECT FOR REVIEW- SEE SPECIFICATIONS. 2.2.2 LOCATIONS FOR SPECIAL ACCESS DOORS AND HATCHES SHALL BE DETAIL WITH AV VENDOR &ARCHITECT. A2-3 ) PRICE AS ADD ALTERNATE: TO REPLACE EXISTING SCONCES WI COORDINATED WITH ALL TRADES AND APPROVED BY THE ARCHITECT. ANY NEW; $800/FIXTURE ALLOWANCE -:'._.:•::;_ 112" GYPSUM BOARD ON DRYWALL SUSPENSION SYSTEM. PAINT PT-1 FLAT FINISH U.N.O. REFER TO This drawing is the property of Associated 5 START W/FULL CEILING TILE HERE. '�"','�' '���' 2.1 GENERAL CEILING NOTES: ITEMS LOCATED ABOVE GYP BD CEILINGS WHICH REQUIRE REGULAR ACCESS CGYPSUM BOARD CEILING FINISH SCHEDULE Space Design, Inc. and is not to be SHALL BE RELOCATED TO AN AREA IDENTIFIED BY THE ARCHITECT TO - reproduced or copied in whole or part. It is 2.1.1 REFER TO GENERAL REFLECTED CEILING STANDARDS FOR TYPICAL PREVENT THE NEED FOR ACCESS PANELS. not to be used on any other project and is to INFORMATION. OPEN TO EXISTING STRUCTURE be returned upon request. Scales as stated 2.2.3 PROVIDE ACOUSTICALLY-LINED "Z" BOOTS AT ALL TRANSFER DUCTS AND D . f . EXISTING EXPOSED CEILING PAINT OUT PT 1; PAINT ALL EXPOSED MEP ITEMS PT 1. herein are for reference only as normal 2.1.2 INSPECTIONS AS REQUIRED BY LOCAL AUTHORITIES SHALL BE COMPLETED WHERE RETURN VENTILATION IS REQUIRED AT FULL-HEIGHT PARTITIONS. reproduction processes may alter the PRIOR TO CLOSING OF CEILING. - - accuracy of original drawings. 2.2.4 COORDINATE WORK BETWEEN THE ENGINEERING AND THE SUSPENDED BAFFLES SEE DETAIL 9/A7.21 Associated Space Design, Inc. 2016 2.1.3 THE FINISHED CEILING PLANE SHALL BE LEVEL,TRUE, AND SQUARE. ALL ARCHITECTURAL DRAWINGS: E LIGHTS, SPRINKLER HEADS, HVAC AND OTHER ELEMENTS INCORPORATED IN ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN WITH RESPECT SPEC: PLASTIC LAMINTE FINISH - FL-2 CEILING CONSTRUCTION SHALL BE ALIGNED WITH CEILING PLANE TO AESTHETIC CONSIDERATIONS, QUANTITY, LOCATIONS FOR FIXTURES, DEVICES ETC. VERIFY QUANTITIES (NEW OR EXISTING) INDICATED ON PLANS. SUSPENDED TECTUM PANELS SEE DETAIL 10IA7.21 2.1.4 FASCIAS 1 SOFFITS SHALL BE LEVEL AND TRUE, FREE OF SURFACE MECHANICAL AND ELECTRICAL CEILING PLAN SHALL GOVERN WITH RESPECT 6 CODED NOTES 5 ALTERNATES NOTES A2-X FSPEC: ARMSTRONG TECTUM SHAPES & CLOUDS COLOR TBD DISTORTION AND DIMENSIONED ACCORDING TO DETAILS SHOWN. TO FUNCTIONAL CONSIDERATIONS AND OVERALL SCOPE OF WORK. 1 CODED NOTE 2.1.5 ELECTRICAL, MECHANICAL AND PLUMBING ELEMENTS SHALL NOT COME IN 2.3 LAMPING 1 SWITCHING: TYPE DESCRIPTION MANUFACTURER MODEL COMMENTS *++�+Q�+�Q+•+Q� s+++.r++++++++++++� SUSPENDED FELT PANELS SEE DETAIL 11/A7.21 CONTACT WITH CEILING CONSTRUCTION EXCEPT AS REQUIRED BY PENETRATIONS F.1 LED LINEAR-SUSPENDED ALW SUPERPLANE 2.5- LENGTHS VARY; FIXTURES& LENSES TO HAVE SEAMLESS 'T', 'L''X' G �+QQ++O+�+�� 2.3.1 WHEN ENGINEERING DOCUMENTS DO NOT EXIST: *, i++++++++*+++++� SPEC: FIZZ FELT AKUSTIKA 10 WI WRAPPED EDGE- COLOR TBD 2.1.6 DIMENSIONS: ALL DOWNLIGHTS (INCANDESCENT OR LOW VOLTAGE) SHALL BE ON A SINGLE SP2.SS S MED 80 3500 0110VIS CRIS N BK UNV CONNECTIONS. A. DO NOT SCALE FROM THESE DRAWINGS. WRITTEN DIMENSIONS TAKE DIMMER RESPECTIVELY. F.2 RECESSED LED LINEAR ALW SUPERPLANE 2.5 RECESSED - LENGTHS VARY PRECEDENCE OVER GRAPHIC PRESENTATION. DETAIL DIMENSIONS TAKE ALL WALL WASHERS SHALL BE ON DIMMERS PER ARCHITECT'S INSTRUCTION.PRECEDENCESP2.5RIF TGRID19116 S** MED 80 3500 0110V/S CRIS N WH UNV CEILING r Q'-0" CEILING HEIGHT FROM A.F.F. NOTIFY ARCHITECTO OF ANY DIMENSIONAL ONAL DISCREPANCIES.ANY CONDITIONS ALL OFFICES CORRIDORS SHALL BE SWITCHED ON DUAL-TECHNOLOGY MOTION SENSORS. F.3A LED DOWNLIGHT-ACT CEILING FOCALPOINT D C4D�R0-1500L-277-L11-T-Lc4-RD-1500L-35K-DN-CD-WP 3 CEILING TYPE LEGEND SYMBOL l I Ai CEILING(VE B. TYPE IFY ALL XISTING CODITION) -- REQUIRING MODIFICATION TO THE DIMENSIONS SHALL BE BROUGHT TO THE ALL INTERIOR ENCLOSED ROOMS SHALL BE ON DUAL-TECHNOLOGY MOTION F.3B LED DOWNLIGHT-GWB FOCALPOINT ID+4.5" ROUND- 1. ALL CEILINGS SHALL BE 10'-0"AFF TYPE 'A', UNO ATTENTION OF THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO SENSORS. CEILING FLC4D-RT-1500L-277-L11-T-LC4-RT-1500L-35K-DN-WH ____ _-- PROCEEDING. F.4 LED PENDANT DOWNLIGHT V2 LIGHTING CORE 200 LX-C2LP-DVD-20833540-T1 WH 2. SPRINKLER HEADS SHALL BE INSTALLED AS FOLLOWS: C. LIGHTS SHOWN IN 2x2 CEILING TILES SHALL BE CENTERED UNO. F.5 BREAKROOM DECORATIVE ROLL AND HILL AGNES CHANDELIER- 14 LIGHTS GWB CEILING - FLUSH CONCEALED TYPE CENTERED ON LIGHT D. COORDINATE THE LOCATION OF LIGHT FIXTURES OR DEVICES NOT SHOWN FIXTURE 2X2 CEILING - SEMI RECESSED, WHITE TRIMMED DIMENSIONALLY WITH THE ARCHITECT PRIOR TO INSTALLATION. F.6 LED 2X4 FIXTURE FOCALPOINT EQUATION 2 - FEQ2-24-AC-XX-35K-1C-UNV-LD1-G2-WH F.7 WALL SCONCE OPTIC ARTS ARM125 ARM 125 MB 35 CW1-004-SR-COXX XX 010 14 3. CENTER CEILING GRID IN ALL ROOMS/AREAS: U.N.O. ARM. 125 PROVIDE SEMI-RIGID SOUND ATTENUATION BLANKETS WHERE INDICATED ON 0 07.01.19 ISSUED FOR PERMIT DETAILS OR PLAN. F.BA BULB PENDANT WI BUZZI BUZZI 1 FIXTURE PLEAT EDEL-BLACK ICE- MEDIUM I FIXTURE SPEC: - PD3106 COORD. MOUNTING HEIGHTS W/ARCHITECT 4. NO SUBSTITUTIONS WILL BE ACCEPTED FOR ANY ACCENT LIGHT FIXTURES PLEAT EDEL SPEC; KUZCO NO: DATE: REMARKS: 2.1.8 VERIFY WITH BUILDING MANAGEMENT IF ENERGY MANAGEMENT SYSTEM IS IN F.BB BULB PENDANT W/BUZZI BUZZI 1 FIXTURE PLEAT EDEL- BLACK ICE- LARGE/FIXTURE SPEC - PD3106 COORD. MOUNTING HEIGHTS WI ARCHITECT 5. COORDINATE LOCATION OF DIFFUSERS, STROBES, SPRINKLERS, ETC. IN DRYWALL CEILING WITH ARCHITECT PRIOR TO INSTALLATION. REVISIONS: USE AND IF TENANT SYSTEMS ARE REQUIRED TO BE TIED INTO SAID MANAGEMENT PLEAT EDEL SPEC; KUZCO SYSTEM. THIS WORK SHALL BE PART OF THE OVERALL CONTRACT IF REQUIRED. F.9 IT SUITE DECORATIVE FIXTURE HIGHTOWER CARAVAGGIO MEDIUM-CAR200- BLACK 6. ALL SWITCHES/SWITCHING FOR AV EQUIPMENT SHALL BE GANGED NEXT TO THE LIGHTING SWITCHES. DRAWING TITLE: F.10 UNDER CABINET TAPE LUMINII KENDO S HIGH EFFICIENCY- KS-""-35K-SO-F-FC-SA-B LENGTHS VARY 2ND FLOOR REFLECTED LIGHTING 7. GC RESPONSIBLE FOR COORDINATING SPRINKLER LAYOUT WITH AV EQUIPMENT LOCATIONS. CEILING PLAN F.11 RECESSED PERIMETER LED ALW SUPERPLANE 2.5 RECESSED PERIMETER MOUNT- VERIFY LENGTH IN FIELD LINEAR HYWGRMUD S"* MED 90 3500K-0/10VIS WH-UNV 8. LOCATION OF ACCESS PANELS TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. ACCESS PANELS 1N GWB CEILINGS TO BE: Q MANUFACTURER: WILLIAMS BROTHERS (OR EQUAL) F.12 GAMEROOM DECORATIVE SONNEMAN ATELIER 8-LIGHT PENDANT COORD. MOUNTING HEIGHT W/ARCHITECT SERIES: WB RDW 410 SERIES- RECESSED FOR DRYWALL ACCESS DOOR FACE PROJECT NO.: ISSUE DATE: c FIXTURE 28021.00 07.01.19 ,- 9. GYP CEILINGS & GYP CEILINGS W/ FELT TO RECEIVE MUD-IN LINEAR DIFFUSERS. COORDINATE W/ARCHITECT FOR LOCATIONS & PROFILES. DRAWN BY: CHECKED BY: 1- T-- 10. - 10. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS & LOCATIONS, SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE HF AR 6, CENTER OF CEILING TILES & SOFFITS, TYP. U.O.N.; INSTALLER SHALL COORDINATE W/OTHER TRADES TO AVOID CONFLICTS W/ HEAD LOCATIONS & PIPE RUNS. SHEET NUMBER: `^ d N 7 I GENERAL NOTES 4 I FIXTURE SCHEDULE 2 I GENERAL TYPICALS A2.02 i I !tit _g _... ASD SKY L L (V.I.F: I D ) LF.1 (10'-0" E ) F.1 F.1 920 SW 6th Avenue 12th Floor F.1 F.1 - LF.� F.1 !I Portland, OR Ff.-1 I 678A91 .3773 www.asdsky.comit liii � - - - - - - F- - - = � L[ 1 _ L_ u g.\- t b 7� Z-1""�'/ 2-0- I_7•-P1•-P/ 7-P /1••0" 4.0" 7-P �i-0"/f-p"I 7-�" /�--fl"/7•-tr/ 7-P' 1-P/1•-P�, a-IT /1-P/1•-P/ /1-P 1•-'/ 7-P e"J \ q_ q c_ i , (10'-0" I, ) 1OP EQ 4 F.4 - - _ : oF.4 - EaiirioNii � : � THE 7.21 SIM. . .c,: \ \ PARTNERS - , - r = - ,_ ..- ra GROUP 1 F.10 ; I rri F.4 vel I 12'-0" F _,'� - 1 3' _6" 11850 SW 67TH AVE. o 3'-6" w4.;\ I _ I i 3' 6" 'i 4„ ti Q" al FEQ J EQ 1111 SUITE 100 8 �' PORTLAND, OR (3-1 -- 8 F.4 '7.21 ' 1a-o� c. 97223 w �.........ii .\F.10 - __ r 1 19 1=U 2 I BREAKROOM ENLARGED RCP 114" = 1 '-0" (9'-0" C ) :10j . 31_611 3'_�11 ;'c_. II 9=Q^' -'C-- 2" _ .. io " 8. I 8 '���USF F'!'A REMUN '�' 4,• c F.3B ` a 721, 4„4, 7.21 F.3BrA •00•0•�� 14. 8 00� OO��OOOi a, 4, • , A, •• • :��p�$$* l,�) = w� 6526 t!!JJIL ftiii(; t?IIIitI F.8B • tSCO__ re i SAN FRACA NCISCO clj F.3B' •��♦ ii� 1 �•:::::.N• F3Ba d '�d0•0•.... i • 0 �i`� `s, °9.� +. +iii• 11 '.+ 4, ••• 4: ii�i�i�i, 4? 72. ♦• . *A ,��a♦ ♦�����♦ F.8AMinftlift 1 $••$�•'7.21,. :�70$4���� : •♦�.4*.t. * c 1 Fl F.1 0 F.1 j 2'_10" Ei" 2'- 10" Ei„ 2'-1 Q"� „lir This drawing is the property of Associated 1 .- (V-o" C ) 9'-0" C -.7,:.-::10...:: :: „ ' 1, Space Design, Inc- and is not to be ;; ® 5 V.LF. p reproduced or copied in whole or part. It is 1'-0" 1'-0" ® not to be used on any other project and is to TYP TYP be returned upon request. Scales as stated r - - 9'-Q" E herein are for reference only as normal II I reproduction processes may alter the F � - g accuracy of original drawings. a, f + j 7 2- Associated Space Design, Inc- 2016 1+. 5„ ,'' 1 f „1� " N • ..0026 I 1 F.3B-- I ,s F.3B' 0 c v V o- , F.38 F.38 { 9'-0" C • r JI ai �' = 9' Q" C F1.1 F11 F1.1 ,.. i •a _:4 =:•0 3'-6 3'-r".=,.'_• :6.:-p- / . •., ' 9 0" 0 07.01.19 ISSUED FOR PERMIT NO: DATE: REMARKS: REVISIONS: DRAWING TITLE, ENLARGED REFLECTED CEILING PLAN PROJECT NC.: ISSUE DATE: co 28021.00 07.01.19 ..,- ..,- DRAWN DRAWN BY: CHECKED BY: r HF AR a, SHEET NUMBER p CV 1 1 LIVING ROOM ENLARGED RCP 114" = 1 '-0" A2 .51CNI 11 i i •O 0\ ,. A D SKY ___ _. 10P 103CONF. .,-;;--- �\` T.1II ifs O filf-ri-1111' . / '....... � - O ►.:• ��114:1 OFFICE r--.� 6A113 RECEPTION ►'`' 920 SW 6th Avenue . \X01 ���. • /� - 12th Floor OFFICE ( r. 105 OFFICE • +q OFFICE ::.7-77_._ 1 �► ag '''---,c7 T.5 1'3 v...-. w 112 /- 117 Portland, OR ' r-44441111111**- T.3 seeT.1 !r0 �'in• .� OFFICE www.asdsky:Com / 7 MEETING I 116 I104 - le /----- It OFFICE STO GE t C:5 ., 11 -� \çoFCE ,. ASAIL 11.4y`s- kus ' _ OFFICE 115 / loomm.7 f , 102 'Piip 10; OFFICE _-_. ifAcr 106 101>::,.. PAN . a c---\ P.1 108 - OFFICE / ) \ + 1 ,, f 110.4 • f •, r�`,�s. ® OFFICE T.1 ive,T.1 ` '� -------„) 'J ° inn i, •� 109 �% \ill, UM �� WOMEN'S �� P.3 Vii, li• T H E 5583 F PARTNERS / / e (c--.1 MEN'S GROUP ���a • 8*******184411148 � � - 11850 SW 67TH AVE. / SUITE 100 = _asam.Lir �,,, PORTLAND, OR / .../ , 97223 • . , It ill ' ) ,,- , //// 1 Jr, , li.. . --:: _,\ .' / ./ - . ____--) A. irL-T..-11 1 . , ______,...<:<.--,_..,,, • .----- "" .------ . 1 1ST FLOOR - POWER & COMMUNICATIONS PLAN 1/8" = 1 '-0" . ...v.17) ARS, CONDITION WITH NO BACKSPLASH PLUMBING EQUIPMENT SCWEDULE EQUIPMENT SCHEDULE JtlSFP!!A RESILING co. '�� GENERAL POWER AND COMMUNICATION NOTES: V- OR FULL HEIGHT BACKSPLASH SYMBOL DESCRIPTION FINISH/TRIM REMARKS 6526 y 1. SWITCHES, FIRE DEVICES, ETC. SHALL BE GANGED & LOCATED PER TYPE DESCRIPTION I MANE. • MODEL FINISH- REMARKS TYPE DESCRIPTION MANE. MODEL FINISH REMARKS WALL MOUNTED DUPLEX WHITE U.N.0• �. • MOUNTING DIAGRAM SPECIFICATIONS. " q ANERA OUTLET TO BE MOUNTED HORIZONTALLY P.1 BREAKROOM/PANTRY SINK: SINK: NO GARBAGE DISPOSAL T.8 ZIA COFFEE MACHINE REQUIRES WATER LINE IrA 2. GC & EC TO REFER TO AV DOCUMENTS AND COORDINATE WALK-THRU WI AV to SINK& FAUCET ELKAY: ECTSRAD25226TBG; T,9 DRIP COFFEE REQUIRES WATER LINE 0 WALL-MOUNTED DEDICATED DUPLEX WHITE U.N.O �•�j' �Q CONSULTANT FOR EXACT PLACEMENT OF POWER/TELE/DATA OUTLETS, FAUCET: FAUCET: 9159-DST MACHINE Vy_ SPEAKERS AND CONDUITS. REFER TO AV DRAWINGS FOR SPECIFIC DELTA BLACK FINISH T.10 RECESSED REQUIREMENTS.ARCHITECTURAL DRAWINGS ARE FOR INFORMATION - COUNTERTOP- COORD. DETAILS & P.2 MOTHERS SINK: SINK: NO GARBAGE DISPOSAL PROJECTOR SCREEN WALL-MOUNTED QUADRUPLEX WHITE U.N.O PURPOSES ONLY. z ELEVATIONS TEI HTDETERMINE ROOM/LIVING ROOM ELKAY; ELUHAD141455PD; MOUNTING HEIGHTS SINK& FAUCET FAUCET: FAUCET: 9959-DST T.11 LIFT MOUNTED 3. COORDINATE SIZE AND MOUNTING DIMENSIONS OF ALL LCD MONITORS W/AV E= DELTA BLACK FINISH PROJECTOR Cr WALL MOUNTED DATA JACK NUMBER DENOTES DATA DROP QUANTIFY WHITE U.N.O VENDOR. ¢ T.12 COUNTERTOP WATER WELLSYS WS 9000CT REQUIRES WATER LINE P.3 MOP SINK COORD. WI BASE BUILDING Lli DISPENSER WATER This drawing is the property of Associated WALL-MOUNTED TELEPHONE JACK WHITE U.N 0 Space Design, Inc. and is not to be 4. NEW FLOOR CORE LOCATIONS TO BE MARKED, REVIEWED AND APPROVED IN w T.13 EXISTING MICROWAVE PANASONI NN-SC668S p g Lu CABINETS MAY OR MAY NOT OCCUR reproduced or copied in whole or part. It is FIELD BY ARCHITECT, AND TENANT PRIOR TO CORE DRILLING, COORDINATE W/ w EQUIPMENT SCHEDULE C p p FURNITURE VENDOR. I T.14 EXISTING WHIRLPO WRB322DMBB REQUIRES WATER LINE; WALL-MOUNTED COMBINED DATA/PHONE JACK WHITE U.N.O not to be used on any other project and is to u) � REFRIGERATOR/ OL be returned upon request. Scales as stated TYPE; DESCRIPTION I MANF. MODEL FINISH - REMARKS herein are for reference onlyas normal 5. REFER TO ELEVATIONS FOR ADDITIONAL DIMENSIONS OF KEY WALLS AND wFREEZER POWER WHIP FOR FURNITURE AND DATA MILLWORK. ¢ T.15 MAIL/POSTAGE COORD. POWER PROVIDE 2 POWER &2 CAT6 DROPS PER WORKSTATION; COORDINATE EXACT LOCATION reproduction processes may alter the FINISHED FLOOR CONTRACTOR PROVIDED MACHINE REQUIREMENTS W/TENANT WITH FURNITURE VENDOR; PROVIDE CONNECTRAC UNDER-CARPET WIREWAY FROM WALL accuracy of original drawings. C.3 MICROWAVE GE PEM31SFSS WI Associated Space Design, Inc. 2016 TRIM KIT JX827SFSS T.16 TOASTER OVEN # WHIP TO WORKSTATIONS IF NEEDED; PROVED (2) EXTRA DATA PER CLUSTER FOR PRINTERS C.4 18" DISHWASHER GE PDT145SSLSS REQUIRES WATER LINE AND FLOOR CORE - FURNITURE STUB UP FOR POWER, DATA AND AV; COORDINATE EXACT _ DRAIN; INSTALL AT ADA MOUNTING HEIGHTS @ COUNTERTOPS ®F1 LOCATION WI FURNITURE VENDOR; COORDINATE REQUIREMENTS W/TENANT AND AV VENDOR HEIGHT - C.5 UNDER COUNTER SUMMIT AL54• FRIDGE ®F.2 FLOOR CORE - FLOOR MOUNTED OUTLET WITH 4 DUPLEX EACH BLACK U.N.O 7 1 GENERAL NOTES 5 1 GENERAL OUTLET LOCATIONS C.6 GLASS FRONT UNDER SUMMIT AL57G FLOOR CORE - FLOOR MOUNTED OUTLET WITH POWER, DATA AND AV; COORDINATE - COUNTER FRIDGE OF3BLACK U.N.O - REQUIREMENTS Wl TENANT AND AV VENDOR 1 C.7 COMMERCIAL FRIDGE TRUE T-72 -- 1 TYPICAL ELECTRICAL DIMENSIONS PER OFFICE SIZE U.N.O. C.8 COMMERCIAL TRUE T-23F CARD REAPER; COORDINATE W/SECURITY VENDOR. A3.1 PRICE AS ADD ALTERNATE: TO PROVIDE& INSTALL FULLY 2 MONITOR CONNECTED TO SECUIRTY CAMERA IN RECEPTION; COORDINATE W/ FREEZER U - • - RECESSED BOTTLE FILLER IN THIS LOCATION W/POWER. SECURITY VENDOR. C.9 COMMERCIAL GLASS TRUE FLM-54-TSL01 -__ WATERLINE, ETC.AS REQ'D 3 PROVIDE POWER ABOVE CEILING FOR CEILING MOUNTED CAMERA COORD- WITH FRIDGE ROOM SCHEDULER- PROVIDE CAT6 CONNECTIONS FOR TENANT PROVIDED SCHEDULER; _. SECURITY VENDOR. C.10 DISHWASHER GE GDT225SSLSS REQUIRES WATER LINE AND WHERE MOUNTING ON GLASS WALL, PROVIDE REQ'D DATA DROPS ABOVE ACCESSIBLE -- "- 4 PROVIDE POWER AND/OR DATA AS REQ'D FOR SOUND MASKING SYSTEM DRAIN; INSTALL AT ADA CEILING; ROUTE CABLE THROUGH MULLION TO 48"AFF; COORD. ALL REQUIRMENTS W/AV THROUGHOUT OPEN OFFICE. HEIGHT VENDOR AND TENANT 5 AV RACK IN MILLWORK CREDENZA; COORD. EQUIPMENT SPECS AND C.11 STACKED GE GUD27EESN REQUIRES WATER LINE AND • REQUIREMENTS W/AV VENDOR. WASHER/DRYER DRAIN; VENT AS REQ'D PANIC BUTTON; COORDINATE W/SECURITY VENDOR. 6 PROVIDE POWER/DATA FOR DECK/CEILING MOUNTED SPEAKERS FOR FUTURE C.12 COMMERCIAL CHAMPIO UH330 ADA REQUIRES WATER LINE AND INSTALL; COORD. Wl AV VENDOR AND TENANT DISHWASHER N DRAIN 7 PROVIDE STAINLESS STEEL OUTLETS AND COVER PLATES AT THIS LOCATION. ' O+ J-BOX ABOVE CEILING; PROVIDE REQ'D POWER/DATA FOR ABOVE CEILING EQUIP. 0 -- 07.01.19 ISSUED FOR PERMIT 8 COORD. COOLING REQUIREMENTS W/TENANT FOR THIS ROOM. POSSIBLE NEED TENANT PROVIDED NO: DATE: REMARKS: FOR 24/7 COOLING AND/OR EXHAUST FAN FOR BACKUP T.1 TELEVISION SIZES VARY; GC TO PROVIDE LEGEND NOTES: 9 POWER REQUIREMENTS FOR THIS ROOM ARE AS FOLLOWS. COORD. EXACT BACKING AS REQ'D REVISIONS: LOCATIONS W/TENANT PRIOR TO INTALLATION. (2) DEDICATED 240V 40 AMP (FOR T.2 COPY/PRINT POWER REQUIREMENTS 1. THE SUFFIX"GFI" WITH ANY OUTLET INDICATES THAT THE OUTLET IS A GROUND FAULT INTERRUPT OUTLET. DRAWING TITLE: FUTURE BATTERY UNIT), (3) DEDICATED 120V 30AMP (FOR CURRENT BATTERY VARY; ENGINEER TO CONFIRM 2. THE SUFFIX"E'WITH ANY OUTLET INDICATES THAT THE OUTLET IS EXISTING TO REMAIN. UNIT), (4) DEDICATED 120V 30AMP CIRCUITS, (1) DEDICATED 120V 20AMP CIRCUIT, (1) WITH SPEC FOR EACH3. SWITCHES, FIRE DEVICES, ETC. SHALL BE GANGED AND LOCATED PER MOUNTING DIAGRAM SPECIFICATIONS. � ST FLOOR POWER AND SHARED 120V 20AMP (UP TO 4 RECEPTACLES) LOCATION 4. REFER TO AV DOCUMENTS & COORDINATE WALK THRU W/AV CONSULTANT FOR EXACT PLACEMENT OF POWER/TELE/DATA OUTLETS, COMMUNICATIONS PLAN 10 EXISTING JANITOR SINK AND HOT WATER HEATER TO REMAIN. T.3 DESKTOP PRINTER f SPEAKERS AND CONDUITS. REFER TO AV DRAWINGS FOR SPECIFIC REQUIREMENTS. ARCHITECTURAL DRAWINGS ARE FOR INFORMATION 2 11 POWER IN THIS LOCATION TO BE WIRED THROUGH FURNITURE, TO OUTLET ON T.4 BEVI WATER MACHINE REQUIRES WATER LINE PURPOSES ONLY. Q BENCH/TABLE. COORD, REQUIREMENTS W/ FURNITURE VENDOR. PROJECT NO.: ISSUE DATE: CO T.5 SMALL COFFEE REQUIRES WATER LINE 12 COORD. POWER REQUIREMENTS FOR /PAD GRAB'N'GO CHECKOUT SCREEN WI MACHINE REFER TO"MOUNTING HEIGHTS" ON SHEET A0.01 FOR TYPICAL MOUNTING LOCATIONS AND HEIGHTS OF OUTLETS AND SWITCHES. 4 28021.00 07.01.19 eNsi TENANT'S VENDOR. T.6 ICE MACHINE FOLLETT 15C1100A-NW-CF-ST- REQUIRES WATER LINE 13 NO WET PIPES TO RUN ABOVE IDE CEILING. 00 DRAWN BY: CHECKED BY: 1- T.7 TOASTER I EW1 -- DESIGNATION TYPE HF AR c, # INDICATES NUMBER OF WORKSTATIONS TO SUPPLY SHEET NUMBER ( 6 I ALTERNATE NOTES 4 CODED NOTES O CODEDNOTEI ,...._ N 3 EQUIPMENT LIST 2 LEGEND A3 .01 N I I, I I EMM9 •, , /aASD SKY OFFICE `.__ 11 227 \ --%------------ ., ,.,::-:...:;;;.,'-,,i:-,., 6--:111--. .-- \ �fp MEETIN i�+ • T.1 _.\\.. \ ROOM ti F226 101 2 f( //,(11 ` y1 T.1 OFFICE ` 228 ,'� i. 2f�i__ C.9 60' (12 N .� 920SW6th Avenue = (11 ►k � \ as" i •. - _-_ z 12th Floor IN v 3 I. \.�% OFFICE OFFICE OFFICE 224 Portland, 4R 1. T.1 T.1 ` +t; 229 i1` PHONE T 67$.491 .3773 265 -- ------------ \ �' � '�? � T.1 T.1_ '" � 223 I T.1 ;1, �r�, �•`' 1 6° www°asdsky.com ' • 5+ - �� _ ELEVATOR �: ..f�y PHONE ♦• , ��,t• 1. \ \ i, =J` 2 ti�+fl:� MARKETING t. 230 ♦ 60 B� LOBBY Ik' STOR. * STORAGE ' N �. OFFICE 5661 ii+► 252 /� T.1 *)F.311.1‘ .3 s 1 I MEET/ G - 012 261 .'6,* Nld �' -. �� PHONE ' .0., ' f) PCO F. I FQ to. 11 222 ` 12 N 220 • \\\ E� �� BREAKROOM _ - 1�1 :� i :� O 2 254 11 �_ T 1 e40" C.7 -t' 11 OFFICE �'. .s OFFICE • („A - T.16 - , 221 , 260 BD' 0 R 1 IT SUITE _1 EO 5 ._0 `4 4 N Na0° C.8 250 5 �w. 2 T.1 A. . itl /�*. 1101, w VC ROO 2 C ROOM T.4 *W C ' . 11 21$ e ' - ./../ , OFFICE _, - ..-_-. \\ , 257 0 0 ,../,r,/ .. :. . • T.7 C 10 T.9 I T.6 �` COPY 1 PRINT 11 60 ` x259 - P.1 C.10 T.8 NORTH T.2 _� .1..., i I X40" co I 0� 0",,,, ,o...,,,.'` ®O .-_ -� ,!+ / I X54° C.3 _ .21, 1 ! �� ____-----, 240 Q OFFICE r Ii es., 3 �� �"yam J \ iirN' - \ IDE STORAGE rias 264 '` 0 251 S�� .:-.3 2171 OFFICE i EQ 5'-0" EQ • T H E 263 - f f 'iis OFFICE s- ( WOMEN'S +� 2 =� 206 `y �`+ PARTNERS / . � ._._ 1 fl" 40" L JANITOR 1 QJ ® - - �. OFFICE W+p (10 .� 271 COPY 1 PRINT a 256 MEN'S 'r , ��►�2 A. EXEC. OFFICE �;.+ GROUP �• IF- 50UTH • Ls V �, 2 ., OFFICE T.2 I C.11 I C.12 I T.14 I T.14 5584 f 272 4P CONE. - - •� il ,s C -I ;14 258 -- T.9 EXEC. OFFICE �* hi is OFFICE - / 273 !� uv ��] ® 204 1 2 216 r•, �- T1 Q n 40" P,2 OFFICE ,�.�= _.O 11850 SW 67TH AVE. - 21D -� O // / - *S. • a AFI - c.6 s SUI• TE 100 •`. N. .� 40' �) GFf I SP CONE. T.1 T-0" 26j.tb 0 2 ..,7" I P.2 I C.5 295 •_` - �, `r' N N C.6 til+ OFFICE OFFICE OTHER'S } STOR. 1 `O EXEC. OFFICE T 1 / •• PORTLAND O R 268 �►,' 00M Q.-c 294 " 296 EXEC. OFFICE �_ LF.2 / ��� 215 • •2 -' .�I _�� 0 297 OFFICE ���� �" -- . COATS 211 97223 P. OFFICE2742L��i C•� (� iQ LIVING ROOM .� 203 1, . +� +� OFFICE r�' - = :�' OFFICE " 201 / `►` / `�' 214 / 0 i 280 Mr- r 1 OFFICE ���� 8 '' ,�, COATS d 4 212 /Z1 OFFICE 2 2 ® - EXEC. OFFICE OFFICE 293 ©F.2 275 r% _ 5' 0" Y II 269 1 OFFICE ,r -- __. ;F.2 A 207 +�� 41111. 1 :h► OFFICE 283 OFFICE a. `' Z r _�i, 279 - 289 1 �� �� ilit• ��b f PVi • ` if J ��( f+�• OFFICE S. - IN 3.1.7 �� 0 EXEC. OFFICE > 276 ru OFFICE OFFICE I �` OFFICE 4 . 292 :1 Nr, 284 288 T.11 Li I v 278 2 2 +,+ �+ • Q _ n Nib �rlr - ' �� F 2 OFFICE I - 1-. 11- it.-----'---.. -- : 2 �� 7 �h d� �� �� + 2 1_208 I OFFICE OFFICE -6„ r o •# .2 T.11 285 287 - 1 BOARDROOM 6 ��0,+, ` k�� 2 2 fi O N 202 U %' �� QF.2 T.10 6AOFFICE 2 ! •I 1 291 ®F.2 • T10 � la 8D 8 1 1 2ND FLOOR - POWER & COMMUNICATIONS PLAN 1 /8" = 1 '-0" SOD ARe 4_ el% (SSFP A RENittNG� GENERAL POWER AND COMMUNICATION NOTES: CONDITION WITH NO BACKSPLASH PLUMBING EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE SYMBOL DESCRIPTION FINISH/TRIM REMARKS 0 r) OR FULL HEIGHT BACKSPLASH 12-1 6526 -I � ' 1. SWITCHES, FIRE DEVICES, ETC. SHALL BE GANGED & LOCATED PER . MODEL FINISH- REMARKS TYPEDESCRIPTION MANF. I MODEL FINISH - REMARKS • WALL-MOUNTED DUPLEX WHITE U.N.O 7 MOUNTING DIAGRAM SPECIFICATIONS. _. _ _ TYPE DESCRIPTION MANF \ SAN FHANCISCO- OUTLET TO BE MOUNTED HORIZONTALLYCA P.1 BREAKROOM/PANTRY SINK: SINK: NO GARBAGE DISPOSAL j T.8 ZIA COFFEE MACHINE REQUIRES WATER LINE 0,2. GC & EC TO REFER TO AV DOCUMENTS AND COORDINATE WALK-THRU W/AV o SINK& FAUCET ELKAY; ECTSRAD25226TBG; T.9 DRIP COFFEE REQUIRES WATER LINE 0 WALL-MOUNTED DEDICATED DUPLEX WHITE U.N.O k•Oi_ CONSULTANT FOR EXACT PLACEMENT OF POWER/TELE/DATA OUTLETS, FAUCET: FAUCET: 9159-DST MACHINE SPEAKERS AND CONDUITS. REFER TO AV DRAWINGS FOR SPECIFIC \ DELTA BLACK FINISH WALL MOUNTED QUADRUPLEX WHITE U.N.O REQUIREMENTS.ARCHITECTURAL DRAWINGS ARE FOR INFORMATION COUNTERTOP COORD. DETAILS & T.10 RECESSED ELEVATIONS TO DETERMINE P.2 MOTHERS SINK: SINK: NO GARBAGE DISPOSAL PROJECTOR SCREEN PURPOSES ONLY. cn ROOM/LIVING ROOM ELKAY; ELUHAD141455PD; z MOUNTING HEIGHTS T.11 LIFT MOUNTED p SINK& FAUCET FAUCET. FAUCET. 9959 DST PROJECTOR ,• WALL-MOUNTED DATA JACK- NUMBER DENOTES DATA DROP QUANTITY WHITE U.N.O 3. COORDINATE SIZE AND MOUNTING DIMENSIONS OF ALL LCD MONITORS W/AV M DELTA BLACK FINISH VENDOR. Q > P.3 MOP SINK COORD. W/ BASE BUILDING T.12 COUNTERTOP WATER WELLSYS WS 9000CT REQUIRES WATER LINE IliDISPENSER WATER WALL-MOUNTED TELEPHONE JACK WHITE U.N.D This drawing is the property of Associated 4. NEW FLOOR CORE LOCATIONS TO BE MARKED, REVIEWED AND APPROVED IN w T.13 EXISTING MICROWAVE PANASONI NN-SC668S Space Design, Inc. and is not to be w CABINETS MAY OR MAY NOT OCCUR reproduced or copied in whole or part. It is FIELD BY ARCHITECT, AND TENANT PRIOR TO CORE DRILLING. COORDINATE W/ w EQUIPMENT SCHEDULE C p p FURNITURE VENDOR. U? T.14 EXISTING WHIRLPO WRB322DMBB REQUIRES WATER LINE; WALL-MOUNTED COMBINED DATA/PHONE JACK WHITE U.N.D not to be used on any other project and is to uREFRIGERATOR/ OL be returned upon request. Scales as stated 5. REFER TO ELEVATIONS FOR ADDITIONAL DIMENSIONS OF KEY WALLS AND TYPE DESCRIPTION MANE. MODEL FINISH REMARKS FREEZER herein are for reference only as normal POWER WHIP FOR FURNITURE AND DATA MILLWORK. Q T.15 MAIL/POSTAGE COORD. POWER reproductionrocesses may PROVIDE 2 POWER &2 CAT6 DROPS PER WORKSTATION; COORDINATE EXACT LOCATION p y alter the > FINISHED FLOOR CONTRACTOR PROVIDED MACHINE REQUIREMENTS WI TENANT • I WITH FURNITURE VENDOR; PROVIDE CONNECTRAC UNDER-CARPET WIREWAY FROM WALL accuracy of original drawings. " C.3 MICROWAVE GE PEM3ISFSS WI I T.16 TOASTER OVEN # WHIP TO WORKSTATIONS IF NEEDED; PROVED (2) EXTRA DATA PER CLUSTE=R FOR PRINTERS Associated Space Design, Inc. 2016 TRIM KIT JX827SFSS C.4 18" DISHWASHER GE PDT145SSLSS REQUIRES WATER LINE AND FLOOR CORE- FURNITURE STUB UP FOR POWER, DATA AND AV; COORDINATE EXACT MOUNTING HEIGHTS @COUNTERTOPS DRAIN; INSTALL AT ADA • LOCATION W/FURNITURE VENDOR; COORDINATE REQUIREMENTS W/TENANT AND AV VENDOR HEIGHT C.5 UNDER COUNTER SUMMIT AL54 • FLOOR CORE - FLOOR MOUNTED OUTLET WITH 4 DUPLEX EACH BLACK U.N.O FRIDGE 7 1 GENERAL NOTES 5 1 GENERAL OUTLET LOCATIONS c.6 GLASS FRONT UNDER SUMMIT AL57G FLOOR CORE- FLOOR MOUNTED OUTLET WITH POWER, DATA AND AV; COORDINATE COUNTER FRIDGE 0F3 REQUIREMENTS W/TENANT AND AV VENDOR BLACK U.N.O C.7 COMMERCIAL FRIDGE TRUE T-72 1 TYPICAL ELECTRICAL DIMENSIONS PER OFFICE SIZE U.N.O. C.8 COMMERCIAL TRUE T-23F CARD READER; COORDINATE W/SECURITY VENDOR. _.__!k3.1--)PRICE AS ADD ALTERNATE: TO PROVIDE& INSTALL FULLY 2 MONITOR CONNECTED TO SECUIRTY CAMERA IN RECEPTION; COORDINATE W/ FREEZER RECESSED BOTTLE FILLER IN THIS LOCATION WI POWER. SECURITY VENDOR. C.9 COMMERCIAL GLASS TRUE FLM-54--TSLO1 WATERLINE, ETC. AS REQ'D 3 PROVIDE POWER ABOVE CEILING FOR CEILING MOUNTED CAMERA; COORD- WITH FRIDGE ROOM SCHEDULER- PROVIDE CAT6 CONNECTIONS FOR TENANT PROVIDED SCHEDULER; SECURITY VENDOR. C.10 DISHWASHER GE GDT225SSLSS REQUIRES WATER LINE AND WHERE MOUNTING ON GLASS WALL, PROVIDE REQ'D DATA DROPS ABOVE ACCESSIBLE 4 PROVIDE POWER AND/OR DATA AS REQ'D FOR SOUND MASKING SYSTEM DRAIN; INSTALL AT ADA CEILING; ROUTE CABLE THROUGH MULLION TO 48"AFF; COORD. ALL REQUIRMENTS WI AV THROUGHOUT OPEN OFFICE. HEIGHT VENDOR AND TENANT 5 AV RACK IN MILLWORK CREDENZA; COORD. EQUIPMENT SPECS AND C.11 STACKED GE GUD27EESN REQUIRES WATER LINE AND - REQUIREMENTS WI AV VENDOR. WASHER/DRYER DRAIN; VENT AS REQ'D PANIC BUTTON; COORDINATE W/ SECURITY VENDOR. 6 PROVIDE POWER/DATA FOR DECK/CEILING MOUNTED SPEAKERS FOR FUTURE C.12 COMMERCIAL CHAMPIO UH330 ADA REQUIRES WATER LINE AND INSTALL; COORD- W/AV VENDOR AND TENANT DISHWASHER N DRAIN * - 7 C) J-BOX ABOVE CEILING; PROVIDE REQ'D POWER/DATA FOR ABOVE CEILING EQUIP. PROVIDE STAINLESS STEEL OUTLETS AND COVER PLATES AT THIS LOCATION. 0 07.01.19 ISSUED FOR PERMIT 8 COORD. COOLING REQUIREMENTS W/TENANT FOR THIS ROOM. POSSIBLE NEED TENANT PROVIDED NO: DATE: REMARKS: FOR 24/7 COOLING AND/OR EXHAUST FAN FOR BACKUP. T.1 TELEVISION SIZES VARY; GC TO PROVIDE LEGEND NOTES: 9 POWER REQUIREMENTS FOR THIS ROOM ARE AS FOLLOWS. COORD. EXACT BACKING AS REQ'D REVISIONS: LOCATIONS W/TENANT PRIOR TO INTALLATION. (2) DEDICATED 240V 40 AMP (FOR T.2 COPY/PRINT POWER REQUIREMENTS 1. THE SUFFIX"GFI" WITH ANY OUTLET INDICATES THAT THE OUTLET ISA GROUND FAULT INTERRUPT OUTLET. DRAWING TITLE: FUTURE BATTERY UNIT), (3) DEDICATED 120V 30AMP (FOR CURRENT BATTERY VARY; ENGINEER TO CONFIRM 2. THE SUFFIX"E" WITH ANY OUTLET INDICATES THAT THE OUTLET IS EXISTING TO REMAIN. 2ND FLOOR POWER AND UNIT), (4) DEDICATED 120V 30AMP CIRCUITS, (1) DEDICATED 120V 20AMP CIRCUIT, (1) WITH SPEC FOR EACH 3. SWITCHES, FIRE DEVICES, ETC. SHALL BE GANGED AND LOCATED PER MOUNTING DIAGRAM SPECIFICATIONS. SHARED 120V 20AMP (UP TO 4 RECEPTACLES) LOCATION 4. REFER TO AV DOCUMENTS & COORDINATE WALK THRU W/AV CONSULTANT FOR EXACT PLACEMENT OF POWER/TELE/DATA OUTLETS, COMMUNICATIONS PLAN 10 EXISTING JANITOR SINK AND HOT WATER HEATER TO REMAIN. T.3 DESKTOP PRINTER SPEAKERS AND CONDUITS. REFER TO AV DRAWINGS FOR SPECIFIC REQUIREMENTS. ARCHITECTURAL DRAWINGS ARE FOR INFORMATION 2 11 POWER IN THIS LOCATION TO BE WIRED THROUGH FURNITURE, TO OUTLET ON T.4 BEVI WATER MACHINE REQUIRES WATER LINE PURPOSES ONLY. Q BENCH/TABLE. COORD. REQUIREMENTS W/ FURNITURE VENDOR. PROJECT NO.: ISSUE DATE: T.5 SMALL COFFEE REQUIRES WATER LINE O 12 COORD. POWER REQUIREMENTS FOR IPAD GRAB'N`GO CHECKOUT SCREEN W/ MACHINE REFER TO "MOUNTING HEIGHTS" ON SHEET A0.01 FOR TYPICAL MOUNTING LOCATIONS AND HEIGHTS OF OUTLETS AND SWITCHES. 28021.00 07.01.19 eri TENANT'S VENDOR. T.6 ICE MACHINE FOLLETT 15C1100A-NW-CF-ST- REQUIRES WATER LINE DRAWN BY: CHECKED BY. v- 13 NO WET PIPES TO RUN ABOVE IDF CEILING. 00 ,- T.7 T.7 TOASTER e1-m- -- DESIGNATION TYPE HF AR a, # -! INDICATES NUMBER OF WORKSTATIONS TO SUPPLY SHEET NUMBER: a N 6 I ALTERNATE NOTES 4 I CODED NOTES CODED NOTE 3 I EQUIPMENT LIST 2 I LEGEND A3 .02 f - 1 I I I - A Ti ,. ...„_, ASD SKY _____-_ _ ____=_____ „..._. -. -all / .•'--z. ___________ __________.,..--------------- -. --'---'-r_...<__,....---i--- --___-_- 15. \ ‘.t-ep. . % \ \ 11 7.41, 1 - ,I. „ PT-3 \\ 191r ( sc1 � \ ii ��_ �'� 920 SW 6th Avenue • • .7.41 •• , \ (c�t1 ) 12th Floor . ---------_,T,- ,,. ,_,,_. , .._. , . . .., _. lk '.. .---f_: . ________ . . . (CPT-1 ) \ , . ..__ 5 �� . (CPT-3) PT- �\\� Portland, 0R �ir-A . I E� T 678.491 .3773 • '� �� < <`jo" C �� (CPT 3} www.asdsky,com ry3) 1 ` iiiill 401.....A v(CPT-3) t. gyp. . .. (CPT 3) 1 (CPT3J PPerr' Q.. . .\ ., � . ..... .. . . ,...,,,L,:.:,.._:.: ; _ illr°,_ (CPT-2) Vilir (CPT-3) - tl:f.A4/i\K \ www._....� �_ 4IL , . t / , 'r - � . • .• (CPT-3) • 1 1 1 i 741 (CPT-3) % \, l (CPT-3) %; • c\- ,; Allii\,,, � 7allorA ( SCI ) z`I / �� IL N. •I N . Oi THE ( SCI PARTNERS • � :,E- T .,_„ fri - GROUP 7.41 ,�► 010111.1 ,--------i \ A b �'��� i 11850 SW 67TH AVE. !• ' - SUITE 100 ,� PORTLAND, OR n r 97223 r ift -. . N ( , ....„ , /./14.******.c. ., • , L . . ,,, ,,., \iiiimmt ±-7---- -__—_* - . . __, ---- _,,._ / --- _ .- ••• ...,-' , ______\ _-- -- -- .47 •-:••' .- % .---.. ...,..:-.-„. 7F—mminemommo._ ! t .1EmisommemIT ammo • -.--- igD AR 1 1ST FLOOR - FINISH PLAN 1/8" = 1 '-'0" 4, sysF r REM�ING pro 0 " V c7 KEY ITEM I MANUFACTURER I DESCRIPTION I REMARKS KEY ITEM MANUFACTURER I DESCRIPTION 1 REMARKS I6526 y GENERAL REQUIREMENTS WALLBASE ACCENT BASE FINISH TAG NOTE: MULTIPLE FINISHES OCCUR AT BASE WALL - *• • SAN�Fti�NCiS{C) NO. FINISH PLAN NOTE WALL ACCENT WALL FINISH TAG SOME WALL LOCATIONS. SEE ELEVATION B-1 BASE JOHNSONITE 2 112" RUBBER BASE; COLOR TBD ROLLED GOODS ONLY; STRAIGHT 1PT-1 PAINT PPG 1013-1 RADISSON WALLS: EGGSHELL FINISH; CA 01, 4.0 REFER TO PARTITION PLAN FOR TYPICAL GENERAL REQUIREMENTS INCLUDING FOR DETAILS. BASE @ CARPET, COVE BASE @ DOORS/TRIM: SEMI-GLOSS FINISH SUBMITTAL REQUIREMENTS. 1 PROVIDE ORGANIC TRANSITION BETWEEN CPT-1 &CPT-2, STAGGER CARPET HARD/RESILIENT FLOORING PT-2 PAINT COLOR: TBD WALLS: EGGSHELL FINISH; k*OF TILES AT 1/3 OFFSET. COORDINATE WITH SHAW CONTRACT FLOORING. ( FLOOR ) ACCENT FLOOR MATERIAL. B-2 BASE JOHNSONITE 2 112" RUBBER BASE; COLOR TBD ROLLED GOODS ONLY; STRAIGHT DOORS/TRIM: SEMI-GLOSS FINISH GENERAL FINISH NOTES: 2 MITER CARPET TILE AS REQUIRED IN ORDER TO SHIFT DIRECTION TO BASE @ CARPET, COVE BASE @ PT-3 PAINT COLOR: TBD WALLS: EGGSHELL FINISH; WORK/ALIGN WITH BUILDING ANGLES. BASE MATERIAL. HARD/RESILIENT FLOORING DOORS/TRIM: SEMI-GLOSS FINISH 4.1 REFER TO GENERAL FINISH LEGEND FOR TYPICAL INFORMATION. 3 APPLY FELT-2 TO POP-UP DRYWALL CEILING IN THIS LOCATION. WB-1 BASE BY MILLWORKER 2 1/2" HIGH WOOD BASE, PAINTED TO MATCH AT CONCRETE FLOOR PT-4 ACCENT PAINT COLOR: TBD WALLS: EGGSHELL FINISH; 4 PAINT DRYWALL CEILING IN THIS AREA PT-6, FLAT FINISH. ADJACENT WALL 4.2 FLOOR: Z FLOOR MATERIAL TRANSITION DOORS/TRIM: SEMI GLOSS FINISH FLOOR 5 PROVIDE WOOD WALL BASE, WB-1, IN AREAS WITH CONCRETE FLOORS. PT-5 ACCENT PAINT COLOR:TBD WALLS: EGGSHELL FINISH; This drawing is the property of Associated 4.2.1 FURNISH AND INSTALL FLASH PATCHING TO PROVIDE FLOOR IN CONDITION TO 6 RUBBER BASE, B-1,TO BE PROVIDED IN THIS ROOM. CPT-1 CARPET SHAW CONTRACT SEEK TILE, 5T216; COLOR: PEAK, 15506 12"X 48'';ASHLAR INSTALLATION DOORS/TRIM: SEMI-GLOSS FINISH DIRECTION OF MATERIALSpace Design, Inc. and is not to be RECEIVE MATERIALS PER DOCUMENTS. COORDINATE DOOR CLEARANCES AND CPT-2 CARPET SHAW CONTRACT DISCOVER TILE; 5T217; COLOR: PEAK, 15506 12"X 48";ASHLAR INSTALLATION I PT-6 ACCENT PAINT COLOR: TBD FLAT FINISH AT DRYWALL CEILING reproduced or copied in whole or part. It is UNDERCUTTING. 1. FINISHES SHALL BE AS FOLLOWS UNO: CPT-3 CARPET SHAW CONTRACT POURED TILE, 5T206; COLOR: MORTAR, 06530 24"X 24"; MONOLITHIC TW-1 TAC-WALL KOROSEAL COLOR: TBD; PROVIDE J-TRIM AROUND ALL REFER TO ELEVATIONS not to be used on any other project and is to INSTALLATION EXPOSED EDGES be returned upon request. Scales as stated 4.2.2 VCT PATTERN AND START POINT SHALL BE PER INSTRUCTIONS ON DRAWING. WALLS PT-1 CPT-4 CARPET SHAW CONTRACT EXPANSE TILE, 5T219; COLOR CLIFF, 15530 12"X 48";ASHLAR INSTALLATION WC-1 WALL COVERING KNOLL TEXTILES SWAY VIVID COLLECTION; WC158113; COLOR: 50"WIDTH; REPEAT: 72"VERTICAL, herein are for reference only as normal SEAMS SHALL BE TIGHT AND INVISIBLE FLOOR SHALL BE CLEANED PER BASE B-1 CPT-5 BREAKROOM RUG SHAW CONTRACT EXPANSE TILE, 5T219; COLOR. MOSS, 15326 12"X 48"; CARPET TILE RUG NOT EVENING TIDE 48" HORIZONTAL reproduction processes may alter the MANUFACTURERS INSTRUCTIONS AND RECEIVE TWO (2) COATS OF NON-SLIP WAX CARPET CPT-1 aaccuracyoof original drawings. WHICH SHALL BE THOROUGHLY MACHINE BUFFED AS PER MANUFACTURER'S CEILING CEILING WHITE BOUND; SEALED CONCRETE FLOOR WC-2 WALL COVERING FILZ FELT 100% MERINO WOOL; COLOR: 150 WEIR 1/8"THICK; 70 3/4"WIDTH; 48 OZ/ g 9 INSTRUCTIONS UNDERNEATH LIN YD WEIGHT Associated Space Design, Inc- 2016 CPT-6 LIVING ROOM/GAME SHAW CONTRACT IDENTITY TILE, 5T237; COLOR: MINT, 35327 9"X 36"; CARPET TILE RUG - NOT WC-3 WALL COVERING CARNEGIE ALPINE, 7362; COLOR: A26 54"WIDTH;ACRYLIC BACKING 4.2.3 PROVIDE TRANSITION STRIPS AT ALL LOCATIONS BETWEEN DISSIMILAR ROOM RUG BOUND; SEALED CONCRETE FLOOR WD-1 WOOD FEATURE BY MILLWORKER TEXTURED RANDOM MIX OF RECLAIMED MIXED 3/4"THICK; 3"-10"WIDTH; 18"-12' FLOORING, INCLUDING SEALED CONCRETE. PROVIDE SAMPLE FOR COLOR UNDERNEATH WALL OAK, AMERICAN GOTHIC, BLACK WALNUT W/ RANDOM LENGTH APPROVAL. TRANSITION STRIP SHALL BE INSTALLED AT CENTERLINE OF DOOR OR AT CPT-7 GAME ROOM RUG SHAW CONTRACT HONEST TILE, 5T236; COLOR: IVY, 35375 9"X 36"; CARPET TILE RUG- NOT MATTE CLEAR FINISH; MATCH ARCHITECT'S CENTERLINE OF CASED OPENING. 4 I CODED NOTES 1 CODED NOTE BOUND; SEALED CONCRETE FLOOR SAMPLE UNDERNEATH WG-1 WALL GRAPHIC PRINTED GRAPHIC ON VINYL WALLCOVERING; ---- 4.2.4 PROVIDE WATERPROOF MEMBRANE AT RESTROOMS. FINISH GWB WALLS TIGHT RUG-1 AREA RUG LIVING MAHARAM FRINGE, 650015, 192 PROVIDE RUG PAD $21/SY MATERIAL COST ONLY - TO FLOOR AND INSTALL SEALANT IN ACCORDANCE WITH WALL TYPES. INSTALL ROOM WT-1 WALL TILE 1 CONCRETE ORIGAMI TILE; 8"X 8" X 5/8" GROUT COLOR: TBD; PROVIDE LATICRETE"HYDRO-BAN" WATERPROOF MEMBRANE AT FLOOR AND +1- 2 1/2" UP RUG-2 AREA RUG PAULIG TEPPICHE BEAT TAMOURE; 3+33 PROVIDE RUG PAD COLLABORATIVE SCHLUTER STRIP AT ALL EXPOSED WALL, IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. CARE SHALL A4-1 PRICE AS ADD ALTERNATE: TO REPLACE EXISTING ELEVATOR RECEPTION TILE EDGES — BE TAKEN TO TIE MEMBRANE INTO FLOOR DRAIN. NOTE THAT CERAMIC TILE BASE IS LOBBY& STAIR CARPET WI NEW: ELEVATOR LOBBY: $24/SF SCHEDULED FOR THIS ROOM AND MEMBRANE SHALL NOT BE VISIBLE ABOVE BASE. MATERIAL COST; STAIR: $20/SF MATERIAL COST. WSC-1 CONCRETE POLISH &SEAL EXISTING CONCRETE SLAB GC &ARCHITECT TO REVIEW T-2 WALL TILE 2 STATEMENTS TILE AK ORIGIN MISTY GRAY MATTE; 2 112"X 10 112" GROUT COLOR: TBD; PROVIDE INSTALL 118" THICK SMOOTH LAYER OF LATEX FORTIFIED THIN SET MORTAR OVER CONDITION OF EXISTING SLAB SCHLUTER STRIP AT ALL EXPOSED WATERPROOFING MEMBRANE. ALLOW THIN SET TO CURE PRIOR TO INSTALLATION COO PRICE AS ADD ALTERNATE TO REPLACE EXISTING BLACK ONCE DEMOLITION IS COMPLETE TILE EDGES OF ADHESIVE AND FLOOR TILE/BASE. SUBMITTAL REQUIRED. GRANITE TILE W/ NEW PORCELAIN TILE AT$7/SF MATERIAL SDT-1 TILE ARMSTRONG EXCELON SDT: 51951 ARMOR GRAY MONOLITHIC INSTALLATION WT-3 WALL TILE 3 DALTILE $5/SF MATERIAL COST ONLY: TBD GROUT COLOR: TBD; PROVIDE ALLOWANCE, MISC SCHLUTER STRIP AT ALL EXPOSED 4.3 WALLS: FELT-1 FELT PLANK FILZ FELT ARO PLANK 4; BCBCC REPEAT: COLOR: TBD ' TILE EDGES FELT-2 FELT FILZ FELT COLOR: TBD -- 4.3.1 PAINT FOR WALL PROVIDE THREE (3) COATS; ONE (1) PRIMER PLUS TWO (2) • GL 1 GLASS SHELF 3/8"TEMPERED GLASS -- FINISH COATS OF EGGSHELL UNO. COLOR AS SPECIFIED. HW-1 CABINET PULL MOCKETT 3"TAB PULL- DP3A; BLACK FINISH TYPICAL AT ALL CABINET DOORS& 4.3.2 APPLY FINISHED WALL TREATMENT- PAINT, WALLCOVERING, TILE, ETC - PRIOR DRAWERS, U.N.O. TO INSTALLING COVER PLATES ON ANY DEVICES. HW-2 CABINET PULL MOCKETT 12" SLENDER BAR PULL- DP252C BLACK FINISH _ 0 07.01.19 ISSUED FOR PERMIT MT-1 BLACKENED STEEL REFER TO ELEVATIONS FOR MORE NO: DATE: REMARKS: 4.3.3 ALL DUCTWORK INSIDE OF AIR DIFFUSERS, WHICH IS VISIBLE WHEN VIEWED KICK PLATE INFORMATION REVISIONS- THROUGH THE AIR DIFFUSER SHALL BE PAINTED FLAT BLACK. MT-2 METAL FAUX REFER TO ELEVATIONS FOR MORE SUPPORT INFORMATION 4.3.4 ALL AREAS OF EXPOSED STRUCTURE SHALL BE PAINTED FLAT WHITE AFTER ALL i DRAWING TITLE: DEVICES, DUCTS, CABLES, ETC HAVE BEEN INSTALLED. PL-1 PLASTIC LAMINATE ABET LAMINATE 1831, SEI 1ST FLOOR FINISH PLAN PL-2 PLASTIC LAMINATE LAB DESIGNS AUTUMN REFLECTIONS; WS325 VRM VERITCAL USE ONLY 4.4 MISCELLANEOUS: LAMINATE 4.4.1 ALL MISCELLANEOUS GRILLS, PLATES, ETC. OCCURRING ON WALLS OR CEILING PL-3 PLASTIC LAMINATE WILSONART COLOR: TBD Q SHALL BE PAINTED TO MATCH THE SURFACES ON WHICH THEY OCCUR UNO. ALL PL-4 PLASTIC LAMINATE WILSONART COLOR: TBD • PROJECT NO.: ISSUE DATE: 0) N METAL SURFACES SHALL BE PRIMED PRIOR TO PAINTING SS-1 SOLID SURFACE CAESARSTONE QUARTZ; RAVEN, 4120; 2CM. THICK, U.N.O. MITERED SQUARE EDGE 28021.00 07.01.19 4.4.2 METAL ELEMENTS AND DOOR/WINDOW FRAMES TO BE PAINTED SHALL HAVE SS-2 SOLID SURFACE WILSONART QUARTZ; HALDI, 04032; 2CM. THICK, U.N.O. MITERED SQUARE EDGE DRAWN BY: CHECKED BY: THREE (3) COATS OF SEMI-GLOSS LATEX ENAMEL FINISH. SS-3 SOLID SURFACE CAESARSTONE COLOR: TBD; 2CM. THICK, U.N.O. MITERED SQUARE EDGE 1 DP AR T d7 SHEET NUMBER: p N 4 CODED NOTES 4 1ALTERNATE NOTES 3 SYMBOL LEGEND & TYPICALS 2 SCHEDULE A4.O1 1 I I E1 ,----, ,„ 7/ . z, \ ASD SKY I __ _________,„ ,, ., „, /7 (CPT-3) )._ i-N __ , \ , . .. ,...„„ ,/ . .,N ___:____:_..:_ .„._ ,----- - , . . / ' O 11 `\, , . 11/\- _ . . \ ��____, , .0” (CPT 3) \ Ir— . ,�� SC-1 , ,. � � . \ /' VW, 1 • 1 `, 920 SW 6th Avenue 1 �:.� , . /44/ �_....,_________ ____________, � (CPT-1)� "--2''' ? "\1\-\\ 20'-a" � LA7.41 ' ► // 12th Floor 1 " . //� ., \� �r4IPVII: //� / (CPT-3) Portland, OR {CPT 3) A741 ' . .// , ,, ....lanail.,502:4 \ \ /, 1 _...:,E.:,..:._:.. ,,,__'_:___,Ii.*1...:::Tr.,11-";'4_ \ T 678.491 .3773 . ./. . ..:0444444.44444444.,,_ 4 tl - :. _ — / www.asdsky.com s CCPT s / t T -- (CPT-5). (CPT 3) - • 04/ r 1 ` • + _ f • '7.41 (CPT-3) C I �.,� K (CPT 3) 1 CPT-3 m a 1: : r C41 ... ® r �� - A4 1 - CPT-1(CPT 3) , ff 4 11 . . j C ) • r (SC-1 ) 11 - °r, ici / 1 1*'' . + +r � ,.� -T-4 11 . {CPT-2} Ilk _. ,� �, �� +�, � � - \\\.: m� i % 1 •' • oi4 , + \ , • (CPT 3) 2 . + _ / I A7.41� r 1 � i► 1\ \' ::/ r � (CPT 2) � - CCPT-�� ,(614 � A61,---- � /ri + � 7.41Bio;- ���� �.",// N.� 1 L - PI r / . :2) / LPT3/ (CPT-2) l - - - �, THE ‘ \ (CPT-3) 4 2: PARTNERS ® CPT 3) '�; GROUP ® 1 `LJ w •7.41 �(� ,/ 11111111 % 11111111111 � `��F_ ® (CPT-2) (CPT 2) �' �� . ( \ ��� 1 \ (CPT-3) C s . \ ' ► y `� P (cPT,� 11850 SW 67TH AVE. i-br, . Com) /.1 +� 1 1i1 (CPT-2) - A.. ... . 1 ® PT-4 - •7.4 �' Q B2 1 % ®4 i SUITE 100 4 illa' B 1 PORTLAND,//iCPT3) (CPT2) _/: _ ..„4/ 1101:11 . ..„„_, f a P2 d +<+� i� • ! ' •% i CCPT 2) � i 5 1 r� ) 97223 • (CPT3 . . . -1 , _. . . . f f O O . , _ .. . . . , .. . . . Acp,3) r = • '7.41 (�11� , - ' " - •- . • _ _ �\• r \ ( SC 1 } ) . z., ••'� ► (CPT-2) • , 18`_0" ___ • C �\ '7� I I WG-1 I a %%VP ( PT )- .. C -3 //`� (CPT-3) (� rr �� � \ ' ��� 7.41 - .. _ .. _. (CPT-1 ) ,, rc°7--- — a. r ,i3/4.1 (CPT-2) h___ iOT3) r (CPT-3) i-` ►- (CPT-3) 7 a 541'�`PT- I 0, . .. . . . ... . . . . _ . . • _ - c 3 f . . . . . . . . . . . . . . . . . . __ . , .. ,. . . __ • _ _ _ . . . . . _ . . . . . . _ , . . . . . ( ) . „�� .• IN _ - CPT-3 r1 , r ,..,,,--,-1- r� � � (7P :T) r (CPT-2) � E��SC-1 ) - •`_ N + Com) m .. CPT 3 (CPT 1 ) • --..., ..Aa' "1 c I ________—,-----T - --- --- --- - (CPT 3) ! ►• • rr (CPT 3) m (CPT 3) _ \_! __ r _ _ - C. 4. I CCPT2) __ - --- ._ �TCPT•4)_._ --_ ft 4 r V-------- --11------- 1 I 2ND FLOOR - FINISH PLAN 1 /8" = 1-0" �� ;p,sF_ AREMLN- �,t.r, KEY I ITEM MANUFACTURER I DESCRIPTION I REMARKS I KEY ITEM MANUFACTURER I DESCRIPTION REMARKS 6526 `'j WALL BASE ACCENT BASE FINISH TAG NOTE: MULTIPLE FINISHES OCCUR AT BASE WALL ;AN r-knNC1SCO. GENERAL REQUIREMENTS NO. FINISH PLAN NOTE I W I ACCENT WALL FINISH TAG SOME WALL LOCATIONS • . SEE ELEVATION or B-1 BASE JOHNSONITE 2 112" RUBBER BASE; COLOR TBD ROLLED GOODS ONLY; STRAIGHT PT-1 PAINT PPG 1013-1 RADISSON WALLS: EGGSHELL FINISH; LA FOR DETAILS. BASE CARPET. COVE BASE DOORS/TRIM: SEMI-GLOSS FINISH 4.0 REFER TO PARTITION PLAN FOR TYPICAL GENERAL REQUIREMENTS INCLUDING @ @ SUBMITTAL REQUIREMENTS. 1 PROVIDE ORGANIC TRANSITION BETWEEN CPT-1 & CPT-2, STAGGER CARPET HARD/RESILIENT FLOORING PT-2 PAINT COLOR: TBD WALLS: EGGSHELL FINISH; 4.01' TILES AT 1/3 OFFSET. COORDINATE WITH SHAW CONTRACT FLOORING. ( FLOOR ) ACCENT FLOOR MATERIAL. B-2 BASE JOHNSONITE 2 1/2" RUBBER BASE; COLOR TBD ROLLED GOODS ONLY; STRAIGHT DOORS/TRIM: SEMI-GLOSS FINISH GENERAL FINISH NOTES: 2 MITER CARPET TILE AS REQUIRED IN ORDER TO SHIFT DIRECTION TO BASE @ CARPET, COVE BASE @ PT-3 PAINT COLOR: TBD WALLS: EGGSHELL FINISH; WORK/ALIGN WITH BUILDING ANGLES. BASE BASE MATERIAL. HARD/RESILIENT FLOORING DOORS/TRIM: SEMI-GLOSS FINISH 4.1 REFER TO GENERAL FINISH LEGEND FOR TYPICAL INFORMATION. 3 APPLY FELT-2 TO POP-UP DRYWALL CEILING IN THIS LOCATION. WB-1 BASE BY MILLWORKER 2 1/2" HIGH WOOD BASE, PAINTED TO MATCH AT CONCRETE FLOOR PT-4 ACCENT PAINT COLOR: TBD WALLS: EGGSHELL FINISH; 4.2 FLOOR: 4 PAINT DRYWALL CEILING IN THIS AREA PT 6, FLAT FINISH. I FLOOR MATERIAL TRANSITION ADJACENT WALL 5 PROVIDE WOOD WALL BASE, WB-1, IN AREAS WITH CONCRETE FLOORS. FLOOR DOORS/TRIM: HEMI GLOSS FINISH PT-5 ACCENT PAINT COLOR: TBD WALLS: EGGSHELL FINISH; This drawing is the property of Associated 4.2.1 FURNISH AND INSTALL FLASH PATCHING TO PROVIDE FLOOR IN CONDITION TO 6 RUBBER BASE, B-1, TO BE PROVIDED IN THIS ROOM. ICPT-1 CARPET SHAW CONTRACT SEEK TILE, 5T216; COLOR: PEAK, 15506 12"X 48"; ASHLAR INSTALLATION DOORS/TRIM: SEMI-GLOSS FINISH DIRECTION OF MATERIAL Space Design, Inc. and is not to be RECEIVE MATERIALS PER DOCUMENTS. COORDINATE DOOR CLEARANCES AND ICPT-2 CARPET SHAW CONTRACT DISCOVER TILE; 5T217; COLOR: PEAK, 15506 12"X 48"; ASHLAR INSTALLATION PT-6 ACCENT PAINT COLOR: TBD FLAT FINISH AT DRYWALL CEILING reproduced or copied in whole or part. It is UNDERCUTTING. 1. FINISHES SHALL BE AS FOLLOWS UNO: CPT-3 CARPET SHAW CONTRACT POURED TILE, 5T206; COLOR: MORTAR, 06530 24"X 24"; MONOLITHIC TW-1 TAC-WALL KOROSEAL COLOR: TBD; PROVIDE J-TRIM AROUND ALL REFER TO ELEVATIONS not to be used on any other project and is to INSTALLATION EXPOSED EDGES be returned upon request. Scales as stated 4.2.2 VCT PATTERN AND START POINT SHALL BE PER INSTRUCTIONS ON DRAWING. WALLS PT-1 ICPT-4 CARPET SHAW CONTRACT EXPANSE TILE, 5T219; COLOR: CLIFF, 15530 12"X 48"; ASHLAR INSTALLATION WC-1 WALL COVERING KNOLL TEXTILES SWAY VIVID COLLECTION; WC1581/3; COLOR: 50"WIDTH; REPEAT: 72"VERTICAL, herein are for reference only as normal SEAMS SHALL BE TIGHT AND INVISIBLE. FLOOR SHALL BE CLEANED PER BASE B-1 CPT-5 BREAKROOM RUG SHAW CONTRACT EXPANSE TILE, 5T219; COLOR: MOSS, 15326 12"X 48 CARPET TILE RUG - NOT EVENING TIDE 48" HORIZONTAL reproduction processes may alter the MANUFACTURERS INSTRUCTIONS AND RECEIVE TWO (2) COATS OF NON-SLIP WAX CARPET CPT-1 WHICH SHALL BE THOROUGHLY MACHINE BUFFED AS PER MANUFACTURER'S CEILING CEILING WHITE BOUND; SEALED CONCRETE FLOOR WC-2 WALL COVERING FILZ FELT 100% MERINO WOOL; COLOR: 150 WEIB 1/8"THICK; 70 3/4"WIDTH; 48 OZ 1 accuracy of original drawings. UNDERNEATH LIN YD WEIGHT Associated Space Design, Inc. 2016 INSTRUCTIONS CPT-6 LIVING ROOM /GAME SHAW CONTRACT IDENTITY TILE, 5T237; COLOR: MINT, 35327 9"X 36"; CARPET TILE RUG - NOT WC-3 WALL COVERING CARNEGIE ALPINE, 7362; COLOR: A26 54"WIDTH; ACRYLIC BACKING 4.2.3 PROVIDE TRANSITION STRIPS AT ALL LOCATIONS BETWEEN DISSIMILAR ROOM RUG BOUND; SEALED CONCRETE FLOOR WD-1 WOOD FEATURE BY MILLWORKER TEXTURED RANDOM MIX OF RECLAIMED MIXED 314"THICK; 3"-10"WIDTH; 18"-12' FLOORING, INCLUDING SEALED CONCRETE. PROVIDE SAMPLE FOR COLOR UNDERNEATH WALL OAK, AMERICAN GOTHIC, BLACK WALNUT W/ RANDOM LENGTH APPROVAL. TRANSITION STRIP SHALL BE INSTALLED AT CENTERLINE OF DOOR OR AT CPT-7 GAME ROOM RUG SHAW CONTRACT HONEST TILE, 5T236; COLOR: IVY, 35375 9"X 36"; CARPET TILE RUG - NOT MATTE CLEAR FINISH; MATCH ARCHITECTS CENTERLINE OF CASED OPENING. 4 I CODED NOTESBOUND; SEALED CONCRETE FLOOR SAMPLE O CODED NOTE UNDERNEATH WG-1 WALL GRAPHIC PRINTED GRAPHIC ON VINYL WALLCOVERING; - 4.2.4 PROVIDE WATERPROOF MEMBRANE AT RESTROOMS. FINISH GWB WALLS TIGHT 'RUG-1 AREA RUG LIVING MAHARAM FRINGE, 650015, 192 PROVIDE RUG PAD $21/SY MATERIAL COST ONLY - - - TO FLOOR AND INSTALL SEALANT IN ACCORDANCE WITH WALL TYPES. INSTALL ROOM WT-1 WALL TILE 1 CONCRETE ORIGAMI TILE; 8" X 8"X 5/8" GROUT COLOR: TBD; PROVIDE LATICRETE "HYDRO-BAN" WATERPROOF MEMBRANE AT FLOOR AND +1- 2 1/2" UP RUG-2 AREA RUG PAULIG TEPPICHE BEAT TAMOURE; 3+33 PROVIDE RUG PAD COLLABORATIVE SCHLUTER STRIP AT ALL EXPOSED WALL, IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. CARE SHALL A4-1 PRICE AS ADD ALTERNATE: TO REPLACE EXISTING ELEVATOR RECEPTION TILE EDGES BETAKEN TO TIE MEMBRANE INTO FLOOR DRAIN. NOTE THAT CERAMIC TILE BASE IS LOBBY &STAIR CARPET W/NEW: ELEVATOR LOBBY: $24/SF SC-1 CONCRETE POLISH & SEAL EXISTING CONCRETE SLAB GC &ARCHITECT TO REVIEW WT-2 WALL TILE 2 STATEMENTS TILE AK ORIGIN MISTY GRAY MATTE; 2 112"X 10 112" GROUT COLOR: TBD; PROVIDE SCHEDULED FOR THIS ROOM AND MEMBRANE SHALL NOT BE VISIBLE ABOVE BASE. MATERIAL COST; STAIR: $20/SF MATERIAL COST. INSTALL 118"THICK SMOOTH LAYER OF LATEX FORTIFIED THIN SET MORTAR OVER A -- CONDITION OF EXISTING SLAB SCHLUTER STRIP AT ALL EXPOSED WATERPROOFING MEMBRANE. ALLOW THIN SET TO CURE PRIOR TO INSTALLATION 2 Y,, PRICE AS ADD ALTERNATE:TO REPLACE EXISTING BLACK ONCE DEMOLITION IS COMPLETE TILE EDGES OF ADHESIVE AND FLOOR TILE/BASE. SUBMITTAL REQUIRED GRANITE TILE W/NEW PORCELAIN TILE AT$7/SF MATERIAL ISDT-1 TILE ARMSTRONG EXCELON SDT; 51951 ARMOR GRAY MONOLITHIC INSTALLATION WT-3 WALL TILE 3 DALTILE $5/SF MATERIAL COST ONLY; TBD GROUT COLOR: TBD; PROVIDE ALLOWANCE. MISC SCHLUTER STRIP AT ALL EXPOSED 4.3 WALLS: FELT-1 FELT PLANK FILZ FELT ARO PLANK 4; BCBCC REPEAT; COLOR: TBD TILE EDGES IFELT-2 FELT FILZ FELT COLOR: TBD - 4.3.1 PAINT FOR WALL PROVIDE THREE (3) COATS; ONE (1) PRIMER PLUS TWO (2) IGL-i GLASS SHELF 3/8"TEMPERED GLASS ---- FINISH COATS OF EGGSHELL UNO. COLOR AS SPECIFIED. HW-1 CABINET PULL MOCKETT 3"TAB PULL- DP3A: BLACK FINISH TYPICAL AT ALL CABINET DOORS & 4.3.2 APPLY FINISHED WALL TREATMENT- PAINT, WALLCOVERING, TILE, ETC - PRIOR DRAWERS, U.N.O. TO INSTALLING COVER PLATES ON ANY DEVICES. I HW-2 CABINET PULL MOCKETT 12" SLENDER BAR PULL- DP252C BLACK FINISH 0 07.01.19 ISSUED FOR PERMIT MT-1 BLACKENED STEEL REFER TO ELEVATIONS FOR MORE N0: DATE: REMARKS: 4.3.3 ALL DUCTWORK INSIDE OF AIR DIFFUSERS, WHICH IS VISIBLE WHEN VIEWED KICK PLATE INFORMATION THROUGH THE AIR DIFFUSER SHALL BE PAINTED FLAT BLACK. MT-2 METAL FAUX REFER TO ELEVATIONS FOR MORE REVISIONS: SUPPORT INFORMATION DRAWING TITLE: 4.3.4 ALL AREAS OF EXPOSED STRUCTURE SHALL BE PAINTED FLAT WHITE AFTER ALL IPL-1 PLASTIC LAMINATE ABET LAMINATE 1831, SEI I 2ND FLOOR FINISH PLAN DEVICES, DUCTS, CABLES, ETC HAVE BEEN INSTALLED. PL-2 PLASTIC LAMINATE LAB DESIGNS AUTUMN REFLECTIONS; WS325 VRM VERITCAL USE ONLY LAMINATE 4.4 MISCELLANEOUS: TBD PLASTIC LAMINATE WILSONART COLOR. 4.4.1 ALL MISCELLANEOUS GRILLS, PLATES, ETC. OCCURRING ON WALLS OR CEILING I PL-3Q SHALL BE PAINTED TO MATCH THE SURFACES ON WHICH THEY OCCUR UNO. ALL IPL-4 PLASTIC LAMINATE WILSONART COLOR: TBD I PROJECT NO: ISSUE DATE: CO METAL SURFACES SHALL BE PRIMED PRIOR TO PAINTING. ISS-1 SOLID SURFACE CAESARSTONE QUARTZ; RAVEN, 4120; 2CM. THICK, U.N.O. MITERED SQUARE EDGE ISS-2 SOLID SURFACE WILSONART QUARTZ; HALDI, Q4032; 2CM. THICK, U.N.O. MITERED SQUARE EDGE 28021.00 07.01-19 4.4.2 METAL ELEMENTS AND DOOR/WINDOW FRAMES TO BE PAINTED SHALL HAVE ISS-3 SOLID SURFACE CAESARSTONE COLOR: TBD; 2CM. THICK, U.N.O. MITERED SQUARE EDGE I DRAWN BY: CHECKED BY. THREE (3) COATS OF SEMI-GLOSS LATEX ENAMEL FINISH. DP AR SHEET NUMBER: p - N 4 I CODED NOTES 4 1 ALTERNATE NOTES 3 1 SYMBOL LEGEND & TYPICALS 2 I SCHEDULE A4.02 i I I - _. ., N, / , _ \\.. , , ,..„,, \„, ASD SKY O ----.-- 10P CONF. 6103 ,/ * ,....--- 400,0 \ 00 \ ii, -, • 40 RECEPTI N•�� 0 •4,quu��,umsuuga�, ` � O .� iiiO3 { 101 �� 0° OFFICE •^. i #10°111:e\_')\ .,, \---------, __ ,, _ ... , Immo X \ i \ a 113 \ 920 SW 6th Avenue ,'': •��1� � r. \ OFFICE 12th Floor � OFFICE OFFICE \��, \ 117 � 105 112 —! �_ Portland, OR ''��._ '�f O I OFFICE \ `�� , \ T 678.491 .3773 t 116 �r www.asdsky.com / ... .,. . _ - �� OFFICE OFFICE r/‘411311 `'��� 111 115 • �j OFFICE • , ., , ,_ lid". A ....-. /� ., 107 IV �1 ' Ji I /�� ,` OFFICE 106 , STORAGE! MAIL 102 \ OFFICE T _ \00.00:7 4:10:40.. PANTRY 110/11111111141111.11 , raEli OFFICE //: 109 \\ / ,/ 1 . WOMEN'S ��! THE / t. ;_ 55831 120 PARTNERS**********8"1/48.1? �= 5582 , GROUP I 1,ium , b \ - 11850 SW 67TH AVE. SUITE 100 I PORTLAND, OR _ll �' �, 97223 1 \ ,) , /., r► J \, rte" u U y , , .____ / __ 11, --- =MEW Iiii.Mili. III � /r _ �.. rEMINIIIIi - __-__ -- _- ------------- --'-r--' ' : ''-j / _MilLt.....,j.....=..__,_..,qr.. _._-- --- 1 I 1ST FLOOR - FURNITURE PLAN 118" = 1 '-0" � D �Re JOSEPH A REM.ING ' 1. FURNITURE PLAN FOR REFERENCE ONLY. FIELD VERIFY ALL MEASUREMENTS. C� V Cl 6526 1—i_ • SAN F 12ANCISCO. di Ch 464 of c This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2016 0 07.01.19 ISSUED FOR PERMIT NO: DATE: REMARKS: REVISIONS: DRAWING TITLE: 1ST FLOOR FURNITURE PLAN Q PROJECT NO., ISSUE DATE: 28021.00 07.01.19 v DRAWN BY: CHECKED BY, <- r HF AR 0, ,l- SHEET SHEET NUMBER: (V 2 GENERAL NOTES A5.O1 I I 1 ... -----7 /„., , ASD SKY OFFICE _�- —I 11 227 , ,_ .„0/0/0///, / .,\ I 4, \ c:27 (D) o •.• ,,,,,,,X4,- ,-4.\\, 400,, \AL ► ' GAMEROOM OFFICE � , _ Np, �I 253 9 228w \ • IILJ LJ LJ LJ �� CO ,- L� Lir UU �: .000 � O / 920 SW 6th Avenue L J -� • ,_,„ ...40 /s. „ \ \ , \ OFFICE 12th Floor L �. 60111i 0 OFFICE 224 L. n ^ r �+ �. Portland, OR / OFFICE \- -/ i 265 OPEN OFFICE 229 117 T 678.491 .3773 I tj{ / \\••• ••••/\\ ONE26z L J (�, J L J ELEVATOR 141�� CO 9 V/ \ \ E� o LOBBYO12320 SW d h Avem 0 11110` �r00. 11 / MARKETING PHONE ®4o OFFICE O /� STORAGE ,0 \ 1r0 261 STOR. --�1 252230C4' 1):e:04.\10. � I�.eill_RM r� �/ �/ �/ �_ �,�er!e 1• A PHONE ` ` ,����.,�.J ._ r h ro ' *is 222 /,/,- Oe'llit"erPn 1144111111111111111, -wIIIIIIIBREAKROOM C / �®ii �� OFFICE /4 ,*I `' l�i 260 ti • C 3 E OPP. OFFICE ),: , \ 1 221 / r 00 1 IT SUITE • •�� y90 '''Q *• 1....._ / // 250 I' ' t7) /�, s c r Al / // , 11 r• ¢;�� •a ////1 � � OFFICE ;:: � � �/ 11 �/C R''- �,�� b'/ ��,25 r��----7 II Q • a 9� \Y/PRINT C VCROOM �`,� LORTH •/ '/ �` 4114 I 257 �>����� �._ 240011,' Q COLLAR. OFFICE IDF \ST:2) \ ii 267. 264 - _.. \ -- 251 0' 0* OFFICEwoo \ T H E 263 OFFICE / , o _ WOMEN'S 206 Ile Iiii, (� , to 100 ., ♦**CD PARTNERS /liG EXEC.OFFICE iii lir," 44ttvo., (2) COPY 1 PRINT 11-IJANITOR/ ,a I' 205 '-! % GROUP OFFICE i I SOUTH W+D MEN'S 1• �, OPEN OFFIC- ,,,.: • II 256 a P;r ,�27258 _ Y -- �/ OFFICEOFFICE _ r Asb ! s 219 �� N s B EXEC. OFFICE *it / 272 , �! : 204 216 1...„,.1 �- F. " 1 OFFICE I/- 11 /,fir ® _ COFFEE y 2,0 / 11850 SW 67TH AVE. / / fro 41 %//i //: I ,► o c, ' *I SUITE 100 /.."1114111.-; r 4/1/. 40. 1 STOR. 295 8P CONF. IIEXEC. OFFICE EXEC.OFFICE I. OFFICE s . [1 1PORTLAND, OR 72F618cE �, 294 296 297 7)4C 111r; / - '-i / M• �:. I1�11=� y 11/ ® ! 7223 / i*._._. 287H '' ` OFFICE OFFICE H 6 , �� 4 o COATS �', 203 1110 ® s !� LIVING ROOM / OFFICE 00 201 %� 0„y, 280 it o OFFICE COATS ra,�` ► ' •! 212 �_ OFFICEtillf 275 293 / EXEC. OFFICE .1.--- -°°1- / 269 OFFICE OFFICE / SI IS .� 111, r�; , II L ��{ l�i ....,.,,„ OE j �. WO4 1.111 .� 1:::°:1COLLAB. � 279 r / �. 213 i 10,Th 0 0 OFFICE _ 276 r: �r EXEC. OFFICE �� �� � o it IA OFFICE OFFICE -- 292 likkOFFICE284 288 OPEN OFFICE 278 (DI 0111 �� 270 11 !�rLL] OFFICE `' lit I / ntif-4101111 nn tilliti ti 208 COLLAR. Arair -—. 7 , .2.„..o) •-------- [__,71 7 ,---- OFFICE OFFICE C. OPEN OFFICE r� 285 287 r.i �3i t BOARDROOM r I 282r 1111111ft ( 202 I S all OFFICE 0 (C) I. ���� r i a 291 / ill a o 00 0 0 ©1011 P � P' ' cgCgJ V o0 COLLAR. OPEN OFFICE E C A AO.��0 �, 286 290 CJg g . III11 tfaa __. W1‘- 1 1 2ND FLOOR - FURNITURE PLAN 1 /8" = 1-0" �e D ARe �r 1. FURNITURE PLAN FOR REFERENCE ONLY. FIELD VERIFY ALL MEASUREMENTS. p_41‘%. f)SFF'!iA 4ZEMLiNG `�� BSZ6 11, SAN FRANCISCO. Cll � �Or � . �i This drawing is the propertyof Associated Space Design, Inc. and is not to be reproduced or copied in whale or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2016 0 07.01.19 ISSUED FOR PERMIT N . DATE: REMARKS: REVISIONS DRAWING TITLE: 2ND FLOOR FURNITURE PLAN 2 PROJECT NO.: ISSUE DATE 28021.00 07.01.19 L6 DRAWN BY: CHECKED BY: HF AR 6, — -- - --------- -- ---- SHEET NUMBER.2 GENERAL NOTES N 1 ... 1 A5.02 1 I ,_ .._ ASD SKY ALIGN / ,. T.1T.1 i E i Do ,' / ,„ -- Ti i , Ti. Do al LI .,: 920 SW 6th Avenue \ 12th Floor 08° Portland, OR T 678.491 .3773 www.asdsky.com EQ EQ .i 4 I GAMEROOM TV WALL 3/8" = 1 '-0" 10'-0"AFF 11-J9 2"AFF B.O.ACT E TH _- B.O.DRYWALL C PARTNERS _. \ / / , GROUP \ / / 11850 SW 67TH AVE. a \ / / SUITE 100 °° / \ \ PORTLAND, OR 97223 / \ \ . / \, . \ EQ EQ SCHEDULED SCHEDULED EQ EQ SCHEDULED EQ EQ 11 . ,- . DOOR&FRAME DOOR&FRAME DOOR&FRAME 3 I LEVEL 02 - OFFICE ISLAND TYPICAL ELEVATION 3/8" = 1 '-0" 10'-0"AFF IV B.O.ACT , \ \ \ \ \ \ 0 N N \ ea / / / 01) ARe 41 4j„ eJOSEPH A.REMLING , / / / _ 6.526 y / / / -- - f A SAN FRANCISCQ.> �yA, �' EQ EQ EQ SCHEDULED EQ EQ EQ [ SCHEDULED EQ EQ SCHEDULED DOOR&FRAME DOOR&FRAME �f DOOR&FRAME This drawing is the property of Associated Space Design,Inc.and is not to be 2 I LEVEL 02 - TYPICAL INTERIOR STOREFRONT ELEVATION 3/8" = 1 '-0" reproduced or copied in whole or part.It is not to be used on any other project and is to be returned upon request.Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design,Inc.2016 job 10'-0"AFF B.O.CEILING N / \ / \ / ,, 0 07.01.19 ISSUED FOR PERMIT b NO: DATE: REMARKS: i / co REVISIONS: \ , DRAWING TITLE: / \ INTERIOR ELEVATIONS / \ PROJECT NO.: ISSUE DATE: co 28021.00 07.01.19 tri DRAWN BY: CHECKED BY: . EQ EQ SCHEDULED SCHEDULED EQ EQ • .' i HF AR a, DOOR&FRAME DOOR&FRAME SHEET NUMBER: p N 1 I LEVEL 01 - TYPICAL INTERIOR STOREFRONT ELEVATION 3/8" = 1 '-0" A6.01 MINIM 1 - I I 7'-7" A D SKY �10'-0"AFF �10'-0"AFF EQ DIVS B.O. GYP B.O.ACT 13 v 9 7.11% •'7.11 r II /I-, . , .N PL-2 COAT CLOSET tQ I / / \ \ I , / \ \ N \ = PL-2 UPPER CABINETS / \ \ / / 1 1/2" 3'-0" — Ar, 4 0 mml o • SS-3 WATERFALL EDGE N Qo `" 7I . 7 - PL-1 COUNTER 920 SW 6th Avenue 7 12th Floor PROVIDE GROMMET HOLE - \ ' / \ i° OPEN �-,j� T.3 FOR PRINTER CABLES / N Portland, OR N BELOW — PT-3 BELOW WORK SURFACE N ' \ N T 678.491 .3773 -, PL-3 BASE CABINETS&TOE KICKS; V \/ PL-3 BASE CABINETS&TOE KICKS CABINETS TO LOCK ' + HW-1 www.asdsky.Com 4'-41/2" 2'-0" I 1'-6" 1 112" I I 6 4 .. 1 1` '7.11 •7.11 1 112"- 1112" 2'- 91/2" L 2' -0" 1' - 6" 3' -0" VERIFY rTRASH / 1 112 8 1 RECEPTION DESK BACK 3/8" = 1-0" 4 I MAIL ROOM 2 3/8" = 1 '-0" 11'- 1" 4 EQ DIVS 4"10'-0"AFF ji,10'-0"AFF B.O. GYP B.O.ACT THE 9 PARTNERS '7.11 . GROUP / \ / \ / \ / \ , \ / \ \ / \ i. / \ / \ \ \ u N N . / N PL-2 UPPER CABINETS / \ / \ / 11850 SW 67TH AVE. El MOCKETT GROMMET MM3 SUITE 100 CAP AND LINER SET; SATIN --i"'— — SS-3 WATERFALL EDGE N EH T.15 70/ ICI STAINLESS FINISH PORTLAND, OR FELT-1 k f /\ l PL-1 COUNTER 97223 / \ 7fl / j® 11 I,. ‘ EN OPEN PL-3 N \ I I BELOW PL 3 BASE CABINETS&TOE KICKS - MT-1 ' -— 1 1- HW-1 5 EQ SLOTS 3'-0" sIL 7'- 8" 4`\ <12-� 2 7.11, 1, •7.11 1 112" 2 EQ DIVS 3'- 0" 1'-6" / / r 7 1 RECEPTION DESK FRONT 3/8" = 1-0" 3 I MAIL ROOM 1 3/8" = 1-0" � 10'-0"AFF ji410'-0"AFF B.O.ACT Iiirl13.0. GYP EQ—.l• 6'-6" ---EQ tEQ 10'-0" L EQ 1 N '� TW-1 Zo. \ OPEN BEYOND is L EV ARe PL-1 COUNTER PICTURE RAIL- 1/8"THICK / \ I\ n n 'ti 'USFF'!!A aEML,NG / �` PL-2 BASE CABINETS&TOE KICKS BLACK METAL FLAT U / \ / \ / \ 7` --- HW-1 BARSTOCK TRIM; U-SHAPE 6526 \ \ ' 1 ' 1 ' CI 2" DEEP AND 2"TALL; ' N . / . BLOCKING AS REQ'D * SAN Fit/1NC15Gt7 1/61. LA 41(.4 6 ' 7.11 7.11 ' 2'- 51/2" 4'-6" TRASH/RECYCLE/COMPOS— This drawing is the property of Associated Space Design, Inc. and is not to be 6 I TRASH NOOK 3/8" = 1-0" 2 1 RECEPTION ART WALL 3/8" = 1-0" reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. EQ EQ Associated Space Design, Inc. 2016 4 2 1 3 '7.14 •7.14 '7.14 7.14 Ai10'-0"AFF ildb10'-0"AFF B.O. ACT B.O. GYP -- 1 9 LL i •7.11 _ ' — r-- .- .._._.---- -:-----„,-----.-- PT-3 PAINTED 314”MDF PANEL WI o7 . . ' . . N\ PL-2 REFRIGERATOR CABINET 6,, 3" 3" 6" SMOOTH FINISH Nv OPEN f . / / PL-2 UPPER CABINETS - w C T•1 BEYOND WI 118"THICK BLACK METAL 1 I I —H_ HW-1 _ } 0 0 . FLAT BARSTOCK TRIM - _ = ALONG ENTIRE TOP AND io Q.: I - r `r I _. _.... . -- BOTTOM EDGE 5 T P.1 - N C3 i T.12 j WT-2 5 — .... °° 0 07.01.19 ISSUED FOR PERMIT r-A - 7.14 SS 2 VERTICAL SURFACE 1",14 �� �r--'-� NO DATE REMARKS > 1: — SS-2 t� , 5S-2 COUNTER REVISIONS: --- _ _ I _ _ DRAWING TITLE: , LI ' / ‘`\-- PL-1 BASE CABINETS&TOE KICKS - a L - i �; 7: T N ., HW-1 — ?� , ___71_ - - ��_ - WD1 1ST FLOOR MILLWORK —L— _ \ i C4 / — 0 - ELEVATIONS Li _ -T I' re \i/ = --1 —i. —1 '2 12 2 5 7 r 1'-0" PROJECT NO.: ISSUE DATE: •7.1 7.12- 7.91 •7.11 / 5' 0" /"_ 7'-5" 5 EQ DIVS 28021.00 07.01.19 u7 3' - 3" 2' -3" 1' -4" 1'-6 1/2" 3'-0" DRAWN BY: CHECKED BY• Y.-- - — 19' 4" r- VERIFY VERIFY CLEAR ADA - i. Cr) I AR SHEET NUMBER: q N 5 I LEVEL 01 - PANTRY 3/8" = 1 '-0" 1 I RECEPTION TV AND COFFEE BAR 3/8" = 1 '-0" A6. 1 1t..... _ . I I I I 10'-0"AFF 10'-0"AFF A D SKY B.O.ACT 1 B.O.ACT � 9'-0"AFF B.O. SOFFIT , _ I — 1 • Vit �� to , a 16# itikk - TW-1 W N „AA. Ai, • , r - 1 ..iiii% \x"..i.. a — - PT-2 - PT-2 1--.- I r 1 N _1 �— - — — T a , PL-1 COUNTER r aMT-2 SUPPORT -- o W — —.-_ 920 SW 6th Avenue PL-2 BASE CABINETS&TOE KICKS _ - 12th Floor ;! 1--= PL 2 SHELVING gill— ,i Portland, OR . w T 678,491 .3773 — --- -_._ www.asdsky.com 1' 0"' I1'-0" • 4 EQ 6'-6" EQ '7.11 ' 4'-7" 2'-0" 6'-6112" 1'-6" e e - i - - e 2 EQ DIVS 12 I CONFERENCE ROOM 220 3/8" = 1 '-0" 8 I LIVING ROOM DISPLAY SHELF 3/8" = 1 '-0" 4 1 COPY/PRINT NORTH ELEVATION 2 3/8" = 1 '-0" 2" 1'-0" EQ EQ EQ 1'-0" 2" 3'-7112" 6' -0" 2 EQ DIVS ji10'-0"AFF 110'-0"AFF B.O. ACTto I iiii9'- B.O. ACT 0"AFF I I THE E 11-}B.O. SOFFIT PT-2 5 9 PARTNERS 7.11 7.11 MT-2 SUPPORT GROUP /\ Nik as , N N . PL-2 UPPER CABINETS PL-2 SHELVING � .. �._ z_ _.~ 11850 SW 67TH AVE. P.2 =. - o NM E SUITE 100 - PL 3 COUNTER&END PANEL `� ��� I `� • i` ® oo ® ao PORTLAND, OR TLAN .. _ - WT-2 ;. II _. - PL-1 BASE CABINETS&TOE KICKS ! „� \ 97223 \ .—_ SS 2 COUNTER I ' - PL 1 COUNTER&END PANEL OPEN 1 - I PL-2 BASE CABINETS&TOE KICKS PL-3 BASE CABINETS&TOE KICKS M BELOW/ _ N / \/ \'. EI `j FIW1 OPEN i \ \' ' '� HW-1 -. / ,I BELOW III 1 \ \ / -- - , �.. _ - x. u 10 5 7 1 4 Ki) 6 t 1 7.1 17.11 7.11- •7.11 •7.1 1 7.11 3" 3'-9 I 6'-0" 1 112 1 _5.61 6 3 0' 4' 0" .-1 1/2" ii 2 EQ DIVS CLEAR ADA VERIFY CLEAR 2 EQ DIVS TRASH / 11 I IT SUITE ISLAND 3/8" = 1-0" 7 I LIVING ROOM COFFEE BAR 3/8" = 1 '-0" 2 I COPY/PRINT NORTH ELEVATION 1 3/8" = 1 '-0" dim 15'-O"AFF IV B.O. STRUCT. - PL-3 UPPER CABINET jib 10'-0"AFF HW-1 10'-0"AFF B.O.ACTii PT-2 B.O.ACT 9'-0"AFF _, EQ 5' 0" EQ — — — 41 LOCKING ROLLED DOWN �B-O. SOFFIT17 I-- • — — — - — — — SCREEN, REFERENCE _ 0 - I TYP. CONSTRUCTION PLAN FOR A n A \ SPEC. x, \ x x. xy x k X a X x -..,____ i T Al, ',' ‘‘.T. .' '.• '',' .. T 2.• '..' '. •.' '..' '- . OPEN N . TW-1 r BEYOND — �, - �. \�,.'�. T X PL-2 SHELVES ' o _ z Z 1 / — 1.12 D ARe m — o Q a PL-3 COUNTER&END PANELS / C'3� ,� � /\ / WT-2 '� 0 l r A 9EMLIN - PL-1 BASE CABINETS&TOE KICKS / \ ., / 6526 C) oo b = SS 2 COUNTER n OD i O / �'- --- \,- / - i. Q / PL-2 BASE CABINETS&TOE KICKS - \ / - \ / \ / \ HW-1 SA RANCIS o • - FURNITURE (FOR REFERENCE) N \ / \ _� - `~ PL 2 GOAT CLOSET&TOE KICK IvA I k iN I f — / BY OTHERS r \/ V I LI _ I Y , - Hw2 8 4 11 3 �` 1 ii: 6'-6" EP 7.1 7.11 7.1 <17.11) •7.11 6'-2" r 1112" 7'-6112" 1112" 2'-4112" 3'-0" 3'-0" 2'-4112" h 3 EQ DIVS ,. .. -- I —p-- , • TRASH/RECYCLE This drawing is the property of Associated Space Design, Inc. and is not to be 10 I IT SUITE TRANSACTION WINDOW 318" = 1 '-0" 6 I LIVING ROOM ELEVATION 1 318" = 1 '-0" 3 I COPY/PRINT SOUTH ELEVATION 2 318" = 1 '-0" nreroduced otobeused orco yothwholeorprojecp nt.Itis d is to - be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2016 3'-6" 6'-0" 3'-7112" --- - -/ -- ----- -- ' -- / VERIFY 2 EQ DIVS {- 10-0"AFF _k 10'-0"AFF - - B.O. GWB B.O. ACT 9'-0"AFF —. B.O. SOFFIT 8 - - 17.11 •7.11 -\ r, ' ; I I MMMM EQ EQ _ 't— =- 7 - ASD SKY 1 _____i ai :________ . 11J Ji _ Cr C W --_ —•- b i CY W 3 — _ b a _— � 920 SW 6th Avenue En uJ I- PT-5 12th Floor v I Portland, OR UJ 1 — WD-1 7 678.491 .3773 i; - 1 — I www.asdSky.com • 7 5 7.13 7.13 6' -2112" 3'-0" '-2 1/2" (_5" 4 1 BREAKROOM LOUNGE 3/8" = 1 '-0" B.O. STRUCT. 5 EQ DIVS ,, � fi p7.13mw ' PT-1 THE m PL-2 FIXED CABINET FRONTS;ALIGN �` PARTNERS � SEAMS W!MILLWORK BELOW ,. - GROUP .0 x c� \N 1 . .^. . . / N PL-2 UPPER CABINETS HW-1 _ - C.3 .v, 11850 SW 67TH AVE. N E a 1'-6" EQ — EQ 1'-6" SUITE 100 r t WIL r iN > C.3 WC 3 �r , PORTLAND, OR _ 97223 ..\ 1 �' SS-2 COUNTER ,' . , / N / . I - - PL-2 BASE CABINETS&TOE KICKS 'I. - o / ' ,/ \ 1 1 1 1 1 1 HW-1 r N , \ 1 I \ / 8'-O" 6'-O" \� \ U / N \/ , U V V 1 i i 1L v I II 9 / \..15 3 •7.1 7.11, 7.11 •7.11 I 2'- 11" 5'-8112" 1'-6" 4'-6" EQ DIVS r i--- i 2 EQ DIVS -RASH/RECYCLE/COMPOST 8 1 ISLAND LONG SIDES 3/8" = 1 '-0" 7 1 ISLAND SHORT SIDES 3/8" = 1 '-0" 3 1 BREAKROOM ELEVATION 3 3/8" = 1 '-0" 41[- B.O. STRUCT. 10'- 0" 2'-6" --- 4EQDIVS Nms� 10'-0"AFF S.O.ACT / \ /\ . . / \ / \ ` \ / \ ,' . \ ` WX X X N N , �- PL-2 UPPER CABINETS \ V \ / \ II / \ / \,,' HW-1 \/ \/ W \-/ 'To-f �- . '\J '' 0- is I ~4 PL-1 FRAME FACE&INTERIOR 11 CJ W l • WC-1 iv J riiir Jun. .... _._.._.__:-. SS-1 COUNTER E 5 C.7 C.8 IL �+ OSF#�.,A RLMLlMG / i1 / / s PL-2 BASE CABINETS&TOE KICKS > '� PL-2 FRAME&INTERIOR u \ / / N H HW-1 tY T.4 ,4012.1.0.1--;:ii 1 6526 1 I \ /I _ _ cA. k \ / 1 FILLER PANEL AS REQ'D [ �iRN F F2J1NC1SrC�. i \I/ I r� it I1 11 f 11 ., ri 314" k( ' 1 3 7 4 �I�FRAME •7A1 •7.11 •7.11 <A7.1 <1-12- 3 .12' •7.13 8 112" 1'-0" 1'- 5" 3'-0" 2, -0" 1 112" 9'- 9" 1 112 2' -6" FILLERS , CLEAR ADA VERIFY ' This drawing is the property of Associated Space Design, Inc. and is not to be 6 I MOTHER'S ROOM 3/8" = 1 '-0" 2 I BREAKROOM ELEVATION 2 3/8" = 1 '-0" reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. - --- Associated Space Design, Inc. 2016 B.O. STRUCT. B.O. STRUCT. 4'-6" 1'-0" EQ EQ 1'- 0" .-2" ,�-. --. -- / -- --4- _ • SIM. 7 ,06,10'-0"AFF _ \ B.O. SOFFIT C') — ii) . 1 id MT-2 SUPPORT ,. l �� - -}-_ - PL-2 SHELVING I I - METRO SMARTWALL GRID I - I I SYSTEM OR VENDOR SUPPLIED 6 - - FOOD DISPLAY; COORD. W/ TENANT - I r T,8 I. _. _ I I r"-= - PL-1 INTERIOR cnT, Cr) li L J PL-4 NOOK INTEIOR T.6 f _ 0 07.01.19 ISSUED FOR PERMIT CV coiiiim - I __ � J oo , ,_D (:)iD -1 NO: DATE: REMARKS' ..•—•,, �' PL-1 COUNTER 1 rl 3 SS-2 COUNTER REVISIONS: o I" C 9 I , - - PL-1 BASE CABINETS&TOE KICKS - -- PL-2 BASE CABINETS&TOE KICKS HW 1 0 1 / 1 / .11. / \ HW-1 DRAWING TITLE: ---I--- CV N \ / 1 I .■ \ 2ND FLOOR MILLWORK PL-2 SURROUND V .� c.10 I c.10 N / I ELEVATIONS CONT. 4 2 3 5 7 I 5 PROJECT NO., ISSUE DATE: 00 .7.13 •7.13 •7.11 •7.11 I e •7.11 •7.11 28021.00 07.01.19 L 3" 4'-8" 3._J" 2'-2" DRAWN BY: CHECKED BY: t..: r♦ / r 3' 0" r 1'-6" 4'-0112" 3'-0" 1' 6" H F AR a)TRASH/RECYCLE VERIFY W/EQUIP 1 CLEAR ADA 1 SHEET NUMBER p N 5 1 BREAKROOM MARKET 3/8" = 1 '-0" 1 1 BREAKROOM ELEVATION 1 3/8" = 1 '-0" A6.22 N I I • I 1 __ I .. �R ... I _ I I EXISTING STRUCTURE 1 ,,. I I ANCHOR RUNNER I I CHANNEL TO STRUCTURE 3 5/$"20 GA METAL STUDS _ BRACED TO STRUCTURE I I W/FASTENERS @ 24"OC ABOVE + I MIN • 1 • R_4\`` FIRESTOP AT EACH CAVITY 1- is 1,.,1 ?- FRT BLOCKING AS REQUIRED 1 '= CEILING SYSTEM; SEE IREFLECTED CEILING PLAN c' -_ I •,_ 1 FOR LOCATION AND TYPE a v �� CEILING SYSTEM;SEE 1 r` 11 1 I ( 1 1 1 I Il �na� I I ( I I ( I ( I ( REFLECTED CEILING PLAN I 5/8"GWB ONE SIDE OF 3 5/8 I 1 f;;1 FOR LOCATION AND TYPE 920 SW 6th Avenue I 20 GAUGE METAL STUDS AT 'lI 16"OC ' � CORNER BEAD,TYP. z I 12th Floor Portland, OR ca 3 5/8"SOUND ATTENTUATION z 1 '_ BLANKETS-FULL HEIGHT 1 112"RECESSED ALUMINUM T 678,491 .3773 U I , = CHANNEL W/NEOPRENE WWW.asdsky.com O I _ GASKET LU 1i` U W I /\ `/ LL IA O i '• �V _ CL 1 ANCHOR RUNNER CHANNEL PARTITION BEYOND w I • ,�''• TO SLAB W/FASTENERS @ 24"OC MIN 1/2"THK CLEAR TEMPERED GLASS WALL BASE AS SCHEDULED FLOORING AS SCHEDULED 1 ,. [�_�1 J v;I m,a o1 1, 14 46' 1"BRUSHED ALUMINUM / ACOUSTICAL SEALANT EACH SIDEILA CHANNEL FASTENED TO SLAB _ 6 I PARTITION - TYPE 203 3" = 1 '-0" 3 I PARTITION - TYPE 1G3 3" = 11-011 TH E PARTNERS GROUP II, ,t 1 ,; NiNN -4111111k 1 EXISTING STRUCTURE N:� EXISTING STRUCTURE N \ I I \ EXISTING STRUCTURE 11850 SW 67TH AVE. ;:. \'''''' SUITE 100 ACOUSTICAL SEALANT; EACH SIDE ACOUSTICAL SEALANT; EACH SIDE i i CHANNELRUNNERANCHOR O STUCTURE PORTLAND, OR ;,1 1 I W/FASTENERS @ 24"OC ANCHOR RUNNERANCHOR RUNNER \ — I I MIN 97223 CHANNEL TO CHANNEL TO / FIRESTOP AT EACH CAVITY STRUCTURE W/ \ STRUCTURE W/ 1, ,^r, \l FASTENERS @ 24"OC FASTENERS @ 24"OC / I`' MIN MIN I I 1 > } -; l CEILING SYSTEM; SEE } CEILING SYSTEM; SEE I ) CEILING SYSTEM; SEE 40111111°1°- REFLECTED CEILING PLAN REFLECTED CEILING PLAN 1 1 REFLECTED CEILING PLAN ` 1 ' FOR LOCATION AND TYPE -' 1 b' FOR LOCATION AND TYPE \ ! FOR LOCATION AND TYPE 1 1 I 1 I � . { 1 1 1_- - 1 1 ry I I I_I { '� II 11 I � _ 1 ,' -': ,„- _„, '-: ". = 5/8"GWB EACH SIDE OF 6"20 '`•. - 518"GWB ONE SIDE OF 3 5/8" I 1- • - 518"GWB EACH SIDE OF 6"20 GAUGE METAL STUDS AT 16" 20 GAUGE METAL STUDS AT GAUGE METAL STUDS AT 16" WOC 16"OC =•: 1 1 ::- OC I z z 6 SOUND ATTENTUATION 3 5/8 SOUND ATTENTUATION 0 I .,• 6 SOUND ATTENTUATION BLANKETS-FULL HEIGHT BLANKETS-FULL HEIGHT z I I¢ BLANKETS-FULL HEIGHT _ 21 - W \ 1 ! I I > ... w - U ' U ,,.3 l W fF,- U •--lit I `i U W w J LL LL W R o .I R ; -.1 ANCHOR RUNNER CHANNEL ANCHOR RUNNER CHANNEL w 1 1�+' ANCHOR RUNNER CHANNEL TO SLAB W/FASTENERS @ TO SLAB W/FASTENERS @ w I TO SLAB W/FASTENERS @ u. �::. -_ 24"OC MIN 24"OC MIN L 1,. -,. 24"OC MIN 1. - . I WALL BASE AS SCHEDULED WALL BASE AS SCHEDULED > I 1 r'"t WALL BASE AS SCHEDULED • .I FLOORING AS SCHEDULED FLOORING AS SCHEDULED _,- :1011111111111111— FLOORING AS SCHEDULED •'-' 'lir , . 1 1 1 . I IIV (IVYin' AV(lVpl 1'l' "V110` 1' at m arm !Hie(,wei'Tv! ;Y (4 in::npr+,u �Ipti,-e�p .alu ndn(1III n,ia 11 a �" , (il '� N III .a 9'1,1 Oil 1a4�I' /111' ACOUSTICAL SEALANT EACH SIDE ACOUSTICAL SEALANT EACH SIDE ACOUSTICAL SEALANT EACH SIDE ,0D ARe 8 PARTITION - TYPE 1S6 3" = 1 '-0" 5 PARTITION - TYPE 103 3" = 11-0" 2 PARTITION - TYPE 1A6 3"' = 11-0" JOSFA- L'" > t.) T i \\ SAN FHANCISCO- "> CIl ,, 8L OJ" I..r_ ... I ;,__ _....,k 1 1 :`., ,.::‘ N EXISTING STRUCTURE I I EXISTING STRUCTURE 1 1 1 1 I I ANCHOR RUNNER ACOUSTICAL SEALANT; EACH SIDE \ I CHANNEL TO STRUCTURE This drawing is the property of Associated I I EXISTING STRUCTURE I I W/FASTENERS @ 24"OG Space Design,Inc. and is not to be =-` ANCHOR RUNNER I I \ 1 I _ MIN reproduced or copied in whole or part.It is _0 - , CHANNEL TO I G_ ANCHOR RUNNER CHANNEL TO I I FIRESTOP AT EACH CAVITY not to be used on any other project and is to ` be returned upon request Scales as stated STRUCTURE W/ .,._ RR • I STRUCTURE W/FASTENERS @ 24" :: I I ;: herein are for reference onlyas normal FASTENERS @ 24"OC OC MIN I� MIN • �,': reproduction processes may alter the ' - = I'`' accuracy of original drawings. c, c, is FIRESTOP AT EACH CAVITY Associated Space Design, Inc.2016 ;'_ } CEILING SYSTEM; SEE c c' FRT BLOCKING AS REQUIRED '.. I CEILING SYSTEM; SEE _ L REFLECTED CEILING PLAN } } L REFLECTED CEILING PLAN -'� I FOR LOCATION AND TYPE I 1 I FOR LOCATION AND TYPE 11111111 / 1111111 (1[ I 1 1 � 1L1II �1 _ 11111111111 �; — CEILING SYSTEM SEE �I�_�I 11 11 I 1 I I LI I I I I — REFLECTED CEILING PLAN ` 518"GWB EACH SIDE OF 3 5/8" FOR LOCATION AND TYPE . _ I ,- 5/8"GWB EACH SIDE OF 3 5/8" - 20 GAUGE METAL STUDS AT — . , I i'_ 20 GAUGE METAL STUDS AT 16"OC I '"� CORNER BEAD,TYP. `-1 16"OC 7 ..„ ,,... ,.._, .. 3 5/8"SOUND ATTENTUATION °' �"' . , --� 3 5/8"SOUND ATTENTUATION a. z 1 1 1/2"RECESSED ALUMINUM z BLANKETS-FULL HEIGHT z 2 I BLANKETS-FULL HEIGHT CHANNELW/NEOPRENE _, CU . 0 GASKET w 01 U • - z w ill f1 w W L.L. awC W ��� CL •OW _'_ 0 - w - PARTITION BEYOND 1-' I : 0 07.01.19 ISSUED FOR PERMIT I— ce NO: DATE: REMARKS: ANCHOR RUNNER CHANNEL w w I, ANCHOR RUNNER CHANNEL u. TO SLAB W/FASTENERS @ t -� 1/2"THK CLEAR TEMPERED w `' TO SLAB W/FASTENERS @ REVISIONS: ''I- 24"OC MIN w , GLASS ,r "1. 24"OC MIN LL IDRAWING TITLE: :'.j WALL BASE AS SCHEDULEDCL y';-� WALL BASE AS SCHEDULED PARTITION TYPES/ - FLOORING AS SCHEDULED V FLOORING AS SCHEDULED PARTITION SECTIONS & F DETAILS f a 111 11trnmIV 1'IIP Elf, INua1fuEntf 1 m.q 1! ,,IA, lttninI(liyrII ^\I,nrarfn i 1 , 11 7,1ia,uk ,Pd 1 1U wa 4b' 1-- PROJECT NO.: ISSUE DATE: 1Lo " BRUSHED ALUMINUM 28021.00 07.0t19 CHANNEL FASTENED TO SLAB DRAWN BY: CHECKED BY: r ACOUSTICAL SEALANT EACH SIDE A 17 ACOUSTICAL SEALANT EACH SIDE AR AR SHEET NUMBER: p N 7 1 PARTITION - TYPE 183 3" = 1 '-0" 4 I PARTITION - TYPE 2G3 3" = V-0" 1 I PARTITION - TYPE 1A3 3" = 1 '-0" A7.01 w A I -- - I I I IIIIIMB NOTE:STAINLESS STEAL'TRASH"OR "RECYCLE"OR"COMPOST"DECAL TO BE NOTE: STAINLESS STEAL"TRASH"OR INSTALLED ONTO FACE OF DOOR. "RECYCLE"OR"COMPOST"DECAL TO BE 2'-0" - REFER TO ELEVATIONS FOR SPECIFIC INSTALLED ONTO FACE OF DOOR. e e LOCATIONS. CONFIRM SPEC.W/ REFER TO ELEVATIONS FOR SPECIFIC 1 1/7 MDF SHELF W/HIGH t, ARCHITECT LOCATIONS.CONFIRM SPEC.WI PRESSURE LAMINATE; REFER ARCHITECT TO ELEVATION FOR FINISH .2 .. , \ Y ASD SKY , .< FRT BLOCKING AS REQUIRED POLISHED CHROME COAT ROD ,-, v--k/KVVJOL Z: , ib! PLASTIC LAMINATE COUNTERTOP; -- --e- . WITH POLISHED CHROME ENDS , SCRIBE TO WALL. REFER TO SOLID SURFACE COUNTERTOP(3CM); ;1 = . ELEVATIONS AND FINISH SCHEDULE FOR SCRIBE TO WALL. REFER TO _ LAMINATE TYPE ELEVATIONS AND FINISH SCHEDULE FOR SPECS 7: 1 2'-1"U.N.O. .- GLASS WALL TILE MAY OCCUR; SEE , E7-: 1 •: , `g,a,' ALL EXTERIOR SURFACES TO BE 3/4" I, ELEVATIONS < . s. i ' MDF W/HIGH PRESSURE LAMINATE. 2'- 1"U.N.O. > . , . - . -___ ___ .., ----- FACE OF PARTITION ui . -J ' REFER TO ELEVATIONS FOR w LAMINATE TYPE ‘ V --..-- FACE OF PARTITION z 0 - .......4.- , _ 16V___Z__IV.Z.__V__Ce._ 1td____1_ill_ „, .. • 1 i .i, :: -.4101...- 1><17t- ' •, ......- • z . :., • •. ., „.. .. • .•, , .--. ..• _ r. :5 5. 5, - .,- --5 .._ --.• • •- :-*, . .• , . • -, -.5 .• -_ - - - --: ... . , , ALL INTERIOR SURFACES TO BE . •' w < ' ,•-;;;;: ; [..•>< X U. . > MELAMINE;COLOR VARIES HIGH w _., .., ..;: . DOOR PULL AS SCHEDULED ,..-: 920 SW 6th Avenue c4 PRESSURE LAMINATE; REFER w ,, _ ,— -' - 'T - - - - - - - II VT DOOR PULL AS SCHEDULED - : TO ELEVATION FOR FINISH 0 i^ 7 , - ADJUSTABLE 3/4"MELAMINE §i 1 - i 1 I _ -7 ;' -: 12th Floor . w - 1 I t I _ ‘ ;'.i I I I I - ' SHELVES :i ! 1 1 1 E ' - Portland, OR u. ..:.: 1 1 1 I 7 ' !II 1 I t _ . I , : k, i ,;. T 678.491 .3773 2 SIDE BY SIDE TRASH CAN MOUNTING KIT ,., 1 i FACE OF PARTITION 0 :: 1 i 1 - ,:: 1 1 = . 1 7 : &BINS(50 QTS.EACH). z SIDE BY SIDE TRASH CAN MOUNTING KIT - 1 wwwiasdsky.corn it: - HAFELE(OR EQUAL) 0 i=" ..: j . &BINS(50 QTS.EACH). w - I , - MODEL: 503.13.533(FROSTED NICKEL) < I I7 , HAFELE(OR EQUAL) -J 1 ”,> , l , CONCEALED HINGE UJ — .,.. ti ,, r 4 - MODEL: 503.13.533(FROSTED NICKEL) 0 H- c •4i--• 1 I I '1/ .s. ALL EXTERIOR SURFACES TO BE 3/4" u.1 ,. - . w . : 1 MDF W/HIGH PRESSURE LAMINATE. I-- —it , 1 ,_ , ALL EXTERIOR SURFACES TO BE 3/4" - , FRT BLOCKING WITHIN WALL CAVITY, w Z 1 1 . , i u_ REFER TO ELEVATIONS FOR LAMINATE ce MDF W/HIGH PRESSURE LAMINATE. , - -AS' : I I I I . : _I JI.T 1/..111? .e '1'Pt AS REQUIRED w w i ) - cc :: 1 1 1 I 'i : TYPE u.. ,. 1 I 1 1 , REFER TO ELEVATIONS FOR LAMINATE -: --a /ALL INTERIOR SURFACES TO BE Lu ,... — " •r 'Z'•I\-- . re 1: 1 1 1 1 MELAMINE ..a . /ALL EINTERIOR SURFACES TO BE 13 MILLWORK — SECTION — COAT ROD AND SHELF 11/2" = V-0" — CONTINUOUS LIGHT STRIP AS -! :. L T _J L _I L. ,. I i I , I 1 1 , i Ik MELAMINE s, s, 1:- SCHEDULED ', ; : L J L J - DOOR PULL AS SCHEDULED c..•..,1 -k : • .___=- ‘--- 7, FRT BLOCKING AS REQUIRED(TYP) (t___ __ :' N ., _ - -4. ! FRT BLOCKING AS REQUIRED(TYP) FACE OF WALL - .. ! ' PLASTIC LAMINATE COUNTERTOP; 1 II SCRIBE TO WALL. REFER TO I ELEVATIONS AND FINISH SCHEDULE PLASTIC LAMINATE BASE; SCRIBE TO \ .• FOR LAMINATE TYPE FLOOR PLASTIC LAMINATE BASE;SCRIBE TO , . FLOOR LOCATION VARIES-SEE PLAN; /MOCKETT GROMMET MM3 CAP AND LINER SET;SATIN STAINLESS FINISH THE SEALANT BEAD 9 I MILLWORK — SECTION — UPPER CABINETS 1 1/2" = 1 '-0" 6 1 MILLWORK — SECTION — BASE CAB. TRASH — PLAM 1 1/2" = 1 '-0" 3 I MILLWORK — SECTION — BASE CAB. TRASH — SS 1 1/2" = V-0" .r ‘ V'* `` PARTNERS - BLOCKING AS REQUIRED GROUP ... ' t , 11850 SW 67TH AVE. SUITE 100 .,, , • HEAVY DUTY COUNTER SOLID SURFACE COUNTERTOP(3CM); PLASTIC LAMINATE COUNTERTOP; PORTLAND, OR - , . , BRACKETS AS NEEDED; PAINTED , SCRIBE TO WALL. REFER TOSCRIBE TO WALL. REFER TO 97223 TO MATCH WALL,TYP. , I ELEVATIONS AND FINISH SCHEDULE FOR - ELEVATIONS AND FINISH SCHEDULE FOR , .. SPECS '• LAMINATE TYPE ' II / . \• WALL TILE MAY OCCUR;SEE ELEVATIONS :1; cs! -. 2'- 1"U.N.O. • • = N. . - / 2'- 1"U.N.O. k A 1 ---• FACE OF PARTITION 1---a--- FACE OF PARTITION 1-,-; V ' 1,' - • - - • , - - , - - • •-. . 1., , _.Z1 afilir Zit t=ti=__:WI=_:11Let_Zee IVA Yttii___ee__V___1'\___, -4Z7: ALL EXPOSED SURFACES TO BE 3/4" ,---,71 Ii. ,;.X MDF W/HIGH PRESSURE LAMINATE. 7i : - .. \ REFER TO ELEVATIONS FOR ii' N I . DOOR PULL AS SCHEDULED ,-,1 '! DOOR PULL AS SCHEDULED , LAMINATE'TYPE ...., . z , F.: , ,..,,_ k :: ; ,1 :t- 1 --t - • C ' > =.1m _ u)- . 12 I DETAIL: COUNTERTOP WORKSURFACE 1 1/2" = I-0" UJ L'll — SINGLE EXTENTION DRAWER H z z O SINGLE EXTENTION DRAWER ADJUSTABLE 3/4"SHELVES - ec 31- - ff F.--- u_ Zi ...‘ --, H u_ _ -,2 ,, _ < -n __, I ___. LIJ > CC .i:I.— > re u_ caUil I -L 0 W , - , - FACE OF PARTITION o ix 0 _ . WI 1.-- :i""` (I ALL EXTERIOR SURFACES TO BE 3/4" 1,„ -' 1, : ce --1 §i ALL EXTERIOR SURFACES TO BE 3/4"MDF MDF W/HIGH PRESSURE LAMINATE. w < _ , , Li• D ::,1 ; REFER TO ELEVATIONS FOR LAMINATE u. n ;4 = LLI CI Ei11—. . -_::: — LU aW/HIGH PRESSURE LAMINATE. REFER TO tX LIJ ,”, TYPE rt w - .. ELEVATIONS FOR LAMINATE TYPE FL- ,,._-' -,'>•< , , ,_ __,-4---- -.NI ALL INTERIOR SURFACES TO BE --1' --, ALL INTERIOR SURFACES TO BE ., _ _,• ., MELAMINE; COLOR VARIES s:. s: MELAMINE;COLOR VARIES :I !- •-• .-1::' , FRT BLOCKING WITHIN WALL CAVITY, - - . 14N___AT. WC AS REQUIRED GLASS WALL TILE AS -41 - ::. .___ 14 :.! II -__-, ., ZN -, , SPECIFIED .- . - - 7---- FRT BLOCKING AS REQUIRED(TYP) ‘..- . FRT BLOCKING AS REQUIRED(TYP) :: . '1 1 -':-'" ' .-• , '' ,, 1 I-„•-•,." CONTINUOUS LIGHT STRIP AS -,s., :4. . . l'. , SCHEDULED : Il FLEXIBLE SEALANT. X-: H if;--‘,-, : SUBMIT COLOR OPTIONS . I I )• -' ' ----- TO ARCHITECT FOR ) 27, ..: PLASTIC LAMINATE BASE;SCRIBE TO k - - PLASTIC LAMINATE BASE; SCRIBE TO APPROVAL - FLOOR FLOOR SOLD SURFACE AS 7', - ,.•-', ,7---4,-- ..T.-..,,,.. .;,.... : ..,--;..$ .i•7',/•---‘,:„,/ NOTED ON -`:-:,,--•--- WALL AS SPECIFIED ._ -. . .., , 8 I MILLWORK — SECTION — UPPER CABINETS OPEN 1 1/2" = V-0" 5 I MILLWORK — SECTION — BASE CAB. DRAWERS — SS 1 1/2" = l '-0" 2 I MILLWORK — SECTION — BASE CAB. DRAWERS — RAM 1 1/2" = 1 '-0" PLASTIC LAMINATE COUNTERTOP; SOLID SURFACE COUNTERTOP(3CM); SCRIBE TO WALL. REFER TO This drawing is the property of Associated SCRIBE TO WALL REFER TO ELEVATIONS AND FINISH SCHEDULE FOR Space Design,Inc.and is not to be SOLID SURFACE COUNTERTOP(3CM); 7, LAMINATE TYPE I,_ ELEVATIONS AND FINISH SCHEDULE FOR reproduced or copied in whole or part.It is if — SCRIBE TO WALL. REFER TO SPECS not to be used on any other project and is to 11 DETAIL — Gli‘SS WALL TILE DETAIL — SS 6" = l '-0" ._, ELEVATIONS AND FINISH SCHEDULE FOR SPECS 2'-1"U.N.O. . i _ .7. WALL TILE MAY OCCUR; SEE ELEVATIONS be returned upon request.Scales as stated herein are for reference only as normal ,,_ /- 2'- 1"U.N.O. ' _ .N.. WALL TILE MAY OCCUR; SEE ELEVATIONS - -a FACE OF PARTITION ,-' -'--•---- FACE OF PARTITION reproduction processes may alter the accuracy of original drawings. 2'-1"U.N.O. c - ',, , - V ..,,,,,,,..:_,.,,,„___,....,..____.__.......__:,....,,,...:, ,- Associated Space Design,Inc.2016 tf.,•::,-, EQ ;.: EQFACE OF PARTITION 1 \ Elg r ..... , • K -: wmailli■••.- lw, .i X.,, .., v .s.DOOR PULL AS SCHEDULED Z:i ;,---;, DOOR PULL AS SCHEDULED ? • COUNTER TYPE AS NOTED ---,. Z „ ' ' A - ON SECTION AND 1 i , DOOR PULL AS SCHEDULED :: ELEVATIONS , '- -•- ----\ 5... , .= , .. , . ..- - % - -.. \ 0 '' Z 5 . • ADJUSTABLE 3/4"MELAMINE SHELVES 0 : '0 ADJUSTABLE 3/4"MELAMINE SHELVES f.i ; . F. ., . 17-* Z \ I < .1 , ;I z > -4-- p §. t: \,,,,, 6 ,, -, OUTLINE OF REQUIRED ADA CLEARANCE w -J ., , W = 7 - .3) LLJ ii Leallkiw 7P-J. —ea! AlEVZ_II_ ZI, I' i. -.I il I I 1 -..a FRT BLOCKING AS REQ'D < > ..: - : \., ' 1 --I 1.-..e' ALL EXTERIOR SURFACES TO BE 3/4" H s, ) ALL EXTERIOR SURFACES TO BE 3/4"MDF 0 _ - •, ALL EXTERIOR SURFACES TO BE 3/4"MDF i , _ ___. . ,_• MDF WI HIGH PRESSURE LAMINATE. .. . W/HIGH PRESSURE LAMINATE. REFER " : . . LLI L' U.I re W/HIGH PRESSURE LAMINATE. REFER TO I : - 1., III . 1 z u_ , o \ , . ELEVATIONS FOR LAMINATE TYPE REFER TO ELEVATIONS FOR LAMINATE - TO ELEVATIONS FOR LAMINATE TYPE w I 1 L.j.. 1 ALL EXPOSED SURFACES I- --- w c _ : ALL INTERIOR SURFACES TO BE ctIlij ' ,- ' ! - ' j TYPE rt §: I ---- TO BE FINISHED; MATCH x i Zst \ .,',.: t4i •••IC ' -.• ALL INTERIOR SURFACES TO BE _-. -z MELAMINECOLOR VARIES i FACE OF DOOR -a w u. , . : , s w - v.) \ - , ALL INTERIOR SURFACES TO BE i ; MELAMINE; COLOR VARIES s - , , \ L T MAX : MELAMINE; COLOR VARIES , CONCEALED HINGE §, .. . , ,, < I N : , ,7 CONCEALED HINGE . DOOR PULL _ 1 , iIm".. :-:,-' 0 07,01.19 ISSUED FOR PERMIT N1 i i V II il 'ir MANF:MOCKETT Zi tsi - 7- NO: DATE: REMARKS: I I/ - CONCEALED HINGE i- _ FRT BLOCKING AS REQUIRED -_ ,;; p. MODEL: DP3A _ ,,'ft .,- s, FRT BLOCKING AS REQUIRED(TYP) I FINISH: BLACK . _..,..,_. -1 (TYP) N .: 1 CN1 :,i Z )(7' '..' DRAWING TITLE: REVISIONS: FRT BLOCKING AS REQUIRED(TYP) V. .1 I [ I ----- - ' MILLWORK SECTIONS & 1 K . PLASTIC LAMINATE BASE; SCRIBE TO DETAILS FLOOR PLASTIC LAMINATE BASE FLOOR PLASTIC LAMINATE BASE; SCRIBE TO < PROJECT NO.: ISSUE DATE: E 28021.00 07.01.19 ea DRAWN BY: CHECKED BY: N-- N ' HF AR ._- o) SHEET NUMBER: El CNI 1 0 I MILLWORK — EDGE PULL @ COUNTER — SS 6" — 11-0" 7 I MILLWORK — SECTION — BASE CAB. SINK — SS 1 1/2" = V-0" 4 I MILLWORK — SECTION — BASE CAB. — RAM 1 1/2" = V-0" 1 I MILLWORK — SECTION — BASE CAB. — SS 1 1/2" = 1 '-0" A7. 1 I cNi r--- =ma I I I — — - I WWW. /\\/ _ Vt SOLID SURFACE COUNTERTOP(3CM);SCRIBE TO WALL. REFER TO ELEVATIONS AND FINISH SCHEDULE FOR PLASTIC LAMINATE COUNTERTOP; PLASTIC LAMINATE COUNTERTOP; SPECS 01 •- ,,: kiii', x ill:,., ii coil,. N. , iiiiiii , SCRIBE TO WALL. REFER TO SCRIBE TO WALL. REFER TO zi ELEVATIONS AND FINISH SCHEDULE I ELEVATIONS AND FINISH SCHEDULE FOR -• „I 2X4 VERTICAL SPLIT BLOCKING FIRE REFER TO PLAN .FOR LAMINATE TYPE REFER TO PLAN LAMINATE TYPE RETARDANT TREATED AS REQUIRED , 1. H 1 OPENING IN WALL-REFER TO ELEVATION y ASD SKY ,..:i _ I .I Ii.1 I Id' traln_A-Arz:_irAr I"ii/Pi I I 4 ntiVAL. I if YZZAIF.0,111112F1141k I ,tiellrel_ e.,z4W_Vtreu.CIIC_i ‘ e: ritz:v,itt,_::,,,z4:1....-_,_i_gfaiovv:i::tyms.i.L .-miLi:: ifir----lijuiv),_ iLztii:= -, ...c ,,-. INTERIOR SURFACE TO BE .1,4 , 1 1><T><-I I ' I 1><T,;•'-,• F.L : PROVIDE CONT.SEALANT BEAD MELAMINE 4 .:.7 I 1- ---- ,: - -i - -' ; •' - - ! ',. ' ' N'\,,, ADJUSTABLE 3/4"MELAMINE , - i\\. BLOCKING AS REQUIRED ...-/ - .7_.' ., , „ ,-.• - 7i ,____,,, / t 1 ..1 ADJUSTABLE 3/4"MDF SHELVES W/ .b .: SHIM AS REQ'D W/EQUIPMENT ADJUSTABLE 3/4"MDF SHELVES W/ - HIGH PRESSURE PLASTIC LAMINATE , . ::, HIGH PRESSURE PLASTIC LAMINATE Ei :------4 - SCHEDULED PARTITION; REFER TO z t. , ON RECESSED STANDARDS ON RECESSED STANDARDS z _ PARTITION PLAN FOR WALL TYPE 0 - --- -- _ `' 1 .L, ! ' - 0 ; . ,, ALIGN EQUIPMENT W/FACE OF COUNTER ' , 7:: \ CONCEALED HINGE. < < „ ,. , .. FACE OF PARTITION - _.or '' W W .. ADJUSTABLE 3/4"MELAMINE SHELVES -,:-.1- 3/4"MDF W/PLASTIC LAMINATE; !_-, 1 0 .. . . , REFER TO ELEVATION&FINISH PLAN I- i-- POWER/DATA AS INDICATED; cc ALL INTERIOR SURFACES TO x REFER TO POWER PLAN .., F.,-. FOR PLASTIC LAMINATE TYPE - ALL INTERIOR SURFACES TO w tsi - _ u.. BE PLASTIC LAMINATE TO a. , , t , !, : BE PLASTIC LAMINATE TO . w ...... _ .. : ,: „.... i KW____11___Ifir zz,__7,2V.____II_I__..: x MATCH EXTERIOR TYPE x , .- MATCH EXTERIOR TYPE EQUIPMENT, N.I.C. 920 SW 6th Avenue .,1 rill LiI 1 , _ :;I L:lieWia, .4444‘_I 1-A1A,Z ilia NE_A___IZ_IV-.,_ .- , - --. 12th Floor k , , • Portland, OR DOOR PULL AS SCHEDULED - 1,,,„,;L.i FACE OF PARTITION T 678.491 .3773 ,7 1 _-<- - — - 1` - FRT BLOCKING AS REQUIRED(TYP) -- .- - 1): • , I FRT BLOCKING AS REQUIRED• --- .11\A ,-,- .. _____ lllllll mull , (TYP) WWW.asdsky.corn -- -1. nAl )1\ —. 1 , V PLASTIC LAMINATE BASE; SCRIBE SCHEDULED BASE 7 . TO FLOOR ; PLASTIC LAMINATE BASE; SCRIBE TO FLOOR z -% 0 101 MILLWORK - SECTION - OPEN SHELVING AT IT WINDOW 1 1/2" = 1 '-0" 8 MILLWORK SECTION OPEN SHELVING AT IT WINDOW 1 1/2" = 1 '-O" 4 I MILLWORK - SECTION EQUIPMENT - SS 1 1/2" = I-0" w 0 ...„ NOTE: ALL CABINET DOORS TO 1-- -. X , RECEIVE RUBBER BUMPERS I w u.. = PLASTIC LAMINATE COUNTERTOP; re * SCRIBE TO WALL, REFER TO ELEVATIONS AND FINISH SCHEDULE FOR LAMINATE TYPE „. • \. , rnit - SCHEDULED EQUIPMENT 3/4”MDF PANEL SHELF W/ 114 111_ I_ _IV _I_ I ___Y,ii /14 _ I_: Vt _ ZIV211 .191,Y IV, HIGH I N PROVIDE CONT.SEALANT BEAD THE _. PRESSURE LAMINATE; . PART'V- REFER TO ELEVATION FOR 1 NERS 1-- .\\\\ TYPE BLOCKING AS REQUIRED - , -- -..- 1'-0" :, -..., i: FIRE RETARDANT TREATED SHIM AS REQ'D W/EQUIPMENT,TO GROUP , / WOOD BLOCKING, FOR BRACKET MATCH COUNTER PLASTIC 4' , TO ATTACHED TOO LAMINATE ------- .,-- 3/4"MDF W/PLASTIC LAMINATE; e/ , , rs____--_,- _ L-i _I:: ' ALIGN EQUIPMENT W/FACE OF COUNTER REFER TO ELEVATION&FINISH PLAN ATTACHED BRACKET TO TOP 1.4 FI, ' ''ff17/- -r n FOR LAMINATE TYPE \ , . PANEL, BEFORE APPLYING i 11850 SW 67TH AVE. _.-., . 0 - BOTTOM PANEL I I SUITE 100 POWER/DATA AS INDICATED; N _ A&M HARDWARE;CONCEALED POWER/DATA AS INDICATED; 1 REFER TO POWER PLAN Cl , FLAT BRACKET OR EQUAL REFER TO POWER PLAN PORTLAND, OR - .. : = -, 97223 ..:. . PROVIDE MITERED CORNERS EQUIPMENT, N.I.C. , a , \ -5-- . SCHEDULED PARTITION; REFER "------------------ SOFFIT TO CONST. PLAN FOR WALL -• . -, \ .:: .P- — TYPE .!. . - FACE OF PARTITION '' -• SCRIBE TO SOFFIT I _ . : . . FIXED PANEL-3/4"MDF W/PLASTIC _ - LAMINATE; REFER TO ELEVATION& I ' SCHEDULED BASE . ---- _ FINISH PLAN FOR PLASTIC LAMINATE TYPE 12 I MILLWORK - SECTION - REFRIGERATOR 1 1/2" = I-0" ;: .. . 7 I MILLWORK - SECTION - FLOATING SHELF 1 1/2" = 1 '-0" 3 I MILLWORK - SECTION - EQUIPMENT - PLAM 1 1/2" = 1-011 -, - PLASTIC LAMINATE COUNTERTOP; PLASTIC LAMINATE REVEAL TO PLASTIC LAMINATE REVEAL TO SCRIBE TO WALL. REFER TO / MATCH EXTERIOR TYPE _ _ , MATCH EXTERIOR TYPE ELEVATIONS AND FINISH SCHEDULE FOR __,_ .____ Zsi 1><1 rx---- 7 LAMINATE TYPE -- '?trI --, 2'-1"U.N.O. .. -,1-.--1111111, .,, „.. — -— „„-AVII I!, 11 ..,. /A. . .:: _, 2X4 VERTICAL SPLIT BLOCKING FIRE _, -------- 2X4 VERTICAL SPLIT BLOCKING FIRE 2' 1U.NO. RETARDANT TREATED AS REQUIRED RETARDANT TREATED AS REQUIRED - . N.. =- ), " , SOLID SURFACE COUNTERTOP(3CM); :: ,I.,., _ '.~-01--- FACE OF PARTITION 1 : SCRIBE TO WALL. REFER TO ELEVATIONS AND FINISH SCHEDULE FOR _ y , , INTERIOR SURFACE TO BE - --. . . INTERIOR SURFACE TO BE \ Lak‘Z MC::WItcri_=:1-2:407AW:17/FA'=1111 -W .f:f F ‘ l- ' SPECS ;: .. MELAMINE :; :: MELAMINE ITIrloo•_........_ 1.>‹,7- . is, _........ .,,,,, ''L ' ,_ 14'"7 - * SCRIBE COUNTER TO WALL _ g: ( ''.-r 7 "I- ' .- ADJUSTABLE 3/4"MELAMINE :: ADJUSTABLE 3/4"MEIAMINEI _lli - r - , at.. ; . ki . „ , ,..„ SHELVES - SHELVES 1 - DOOR PULL AS SCHEDULED P-LAM REVEAL TO MATCH CABINET -_-.. . __ 7-.. _A, DOORS - 1 VTZZAlz_1411/.... I,1111_,ArIt'__:.111___,Z7___AII:f.__I__k- '. : jr: IrnItte.:i Z_Zzzate_IIII:=71 rik II ,-7,---Y,i-A-V:::!:::.4 7.1 -qii VENTILATION SLOT AT BACK OF CABINET ,; ... . . <o) 5; FACE OF SCHEDULED PARTITION - 7.--.., =-1 SCHEDULED PARTITION; REFER TO :: :-.... - - SCHEDULED PARTITION; REFER TO - a : - ., ALL EXTERIOR SURFACES TO BE 3/4"MDF w -..„: - LAMINATE FINISH ON INTERIOR TO . ,,,- PARTITION PLAN FOR WALL TYPE i PARTITION PLAN FOR WALL TYPE :i co z - W/HIGH PRESSURE LAMINATE. REFER z re? :. , MATCH BASE CABINETS , -, i, CONCEALED HINGE. :: ' 7- -- CONCEALED HINGE. 0 0 : 0 .• TO ELEVATIONS FOR LAMINATE TYPE _ ,. —, _. < _ . < cc .. z ____„,_,...--------------- t_ W = * W , 3/4"MDF W/PLASTIC LAMINATE; 3/4"MDF W/PLASTIC LAMINATE; 1 .0 POWER/DATA AS INDICATED0; ..., 0 POWER/DATA AS INDICATED; : REFER TO ELEVATION &FINISH PLAN :: REFER TO ELEVATION &FINISH PLAN w s ° -F-- 1 w c.) REFER TO POWER PLAN - - 0 k 0 0 REFER TO POWER PLAN 0 7--7. FOR PLASTIC LAMINATE TYPE -, FOR PLASTIC LAMINATE TYPE1- .t. - ° . . .- : 1- =. •: 0 0 — Of -.E SCHEDULED EQUIPMENT N.. _ , ,- - W ''.." -- ALL INTERIOR SURFACES TO BE w ' " .A ZzLIZ:AN We 4401\___~.444:::i/z=ic IV/11=7/_ez::ariat,zzz:-7`.' ::§g11,:_rilZ V it—#e`lit114:":1===mKIL L_ISIV, eLTAr-1 i_, : ° s 0 0 IF-- 1;1-l ll ---L‘L'-'— ^'''''"--: w . . 0 _ ,,, MELAMINE; COLOR VARIES w Z•sis ,1111:1•1:::Etlit::=Z:=WC11111:=Ailvial::z__:=7//40:_71-_11:1_1i111:,iai:\ Ce i re egi .(til ' NN. t !' -•' DOOR PULL AS SCHEDULED . A . . 7 zi- '17 I - 7 ' § . . . -, . m.-- _ --,„,,,,,i , „ - - z DOOR PULL AS SCHEDULED 3/4"MDF SUBSTRATE W/P-LAM; REFER - I ' CONCEALED HINGE -,-4-„,. , 0 0 ;. TO ELEVATION&FINISH SCHEDULE FOR POLISHED CHROME COAT ROD F.- 0: I ' 1:_' • . t • 0° . -... ; O _,-,- PROVIDE 1"CONT. SLOT, FOR VENTILATION ,7-----1 . LAMINATE TYPE i-- WITH POLISHED CHROME ENDS < > m 7 . ALL EXPOSED SURFACES TO MATCH ZNI 1 / ,0 ide--- 'IrQ.,,_______ FRT BLOCKING AS REQUIRED 1.1 ,,;.-., 4 t • "4 W ....I W Ft, zz EXTERIOR PLASTIC LAMINATE csi .-, / I.,.1.:.0-.. .. ,. ...°) V • . _.__ ____..„ _ a (TYP) BLOCKING AS REQUIRED 7 / 0 eNIC /4 Ira;1A0St4Ell-li .C2:0#6:11N:!..:1 4*OF ( .., BASE BLOCKING - s "" 1 ' x -I- -,',- POWER/DATA AS INDICATED; ,___ ,, ... , w a. ss „..±. w1 REFER TO POWER PLAN 1 s w - P-LAM BASE TO MATCH CABINET DOOR; _1II PLASTIC LAMINATE BASE; SCRIBE TO SCRIBE P-LAM BASE TO FLOOR z -- FLOOR 0 : , P . ,- < : __,, ,,E"IY___1111C_141____I_BIIVIK/_,Z17::4fdtv,_ZI-z_AVAVA-e_W'_:-7,02,Lirl ,•._, > :f This drawing is the property of Associated w Z.,, 'XI IX ' X I Space Design,Inc.and is not to be _., fl) 11111_:ZIAIIIII:LJ_FAIIIII_ZZ___111* _/1-/AMLJIC_ZI:ZAH:-- 6 I MILLWORK - SECTION - BASE CAB. W/ AV - PLAM 1 1/2" = l '-0" 2 I MILLWORK - SECTION BASE CAB. W/ MICROWAVE 1 1/2" = 11_011 reproduced or copied in whole or part.It is 1- NOTE: ALL CABINET DOORS TO NOTE: ALL CABINET DOORS TO not to be used on any other project and is to X , RECEIVE RUBBER BUMPERS I _ I I MOM .. , .. ,. • • w, , I,n fill11 ---- , -- :11,1,1 , 11V II III II II 111 I All II I \ r-1,,,,.> ' I. .,A"---- ... - --- SOFFIT , i • 2X4 VERTICAL SPLIT BLOCKING FIRE 2X4 VERTICAL SPLIT BLOCKING FIRE RETARDANT TREATED AS REQUIRED . RETARDANT TREATED AS REQUIRED - - -- SCRIBE TO SOFFIT _ - z - O -, , '•' . i . k , FIXED PANEL-3/4"MDF W/PLASTIC .,, ,, ' . . w - LAMINATE; REFER TO ELEVATION& .,, . ., _I FINISH PLAN FOR PLASTIC LAMINATE ., . . : ASD SKY 0 . TYPE -f- !.4 _ . _ = w ,' ., - _ -... SCHEDULED PARTITION; REFER TO E --., SCHEDULED PARTITION; REFER TO PARTITION PLAN FOR WALL TYPE .' . PARTITION PLAN FOR WALL TYPE . t I , ..i __ PLASTIC LAMINATE REVEAL TO -' 1>< 2 MATCH EXTERIOR TYPE FIXED 3/4"MDF W/PLASTIC FIXED 3/4"MDF W/PLASTIC 1 '-i.i .: LAMINATE; REFER TO ELEVATION& N*e- '. :: i'____JelibrzaL Wirt V.•21,2 VLI I I',17/ Z LAMINATE; REFER TO ELEVATION & '7 , •, FINISH PLAN FOR PLASTIC LAMINATE - - FINISH PLAN FOR PLASTIC LAMINATE TYPE TYPE zi, u, IIIVINV_ ,/IIIII141 ,2:iNIKIT JIAIIi 1.4Y ... .. .1- I :04 - ALL EXTERIOR SURFACES TO BE 3/4" 1 - 1.-'' 920 SW 6th Avenue ..., , MDF W/HIGH PRESSURE LAMINATE. I I -„, REFER TO ELEVATIONS FOR 12th Floor:L.: ... ... z ii , LAMINATE TYPE 7 E\ O ,. . ,, ,, „,. _ 'L F-7 Portland, OR ALL INTERIOR SURFACES TO BE :-- ::4_ : T 678.491 .3773 > MELAMINE; COLOR VARIES w :: - 111 n 'i z-- www.asdsky.com "cC ADJUSTABLE 3/4MELAMINE 2._. -Z-- w ::,• „,, SHELVES z 0 w - .,, 'Jr 114 .• ot`;-. NOTE: ALL CABINET DOORS TO i NOTE: ALL CABINET DOORS TO CONCEALED HINGE re .„ RECEIVE RUBBER BUMPERS I .. RECEIVE RUBBER BUMPERS I • [1- 71 .. , . w I I -.- FRT BLOCKING WITHIN WALL CAVITY, ...m..A.-----,---.4, ..,,,,,..I.-Azi.iiii. ' AS REQUIRED t• .--' j ......N ,': CONTINUOUS LIGHT STRIP AS ' SCHEDULED -- 7:- k DOOR PULL AS SCHEDULED -.it -(- SCHEDULED EQUIPMENT t.-- , • - :OE VIKA AI 1114 WIZ____IGVI IZ____III Km eedvitIv_i_ _t7r- '— t, , -_- FRT BLOCKING WITHIN WALL CAVITY, - AS REQUIRED THE : , .: 6 MILLWORK - SECTION - UPPER CAB. W/ FIXED PANEL 1 1/2" = V-0" .,--- N: ' : , PARTNERS ,.• , : , • . . . _ . -..a 3/4"MDF W/PLASTIC LAMINATE; 2 --, 3/4"MDF W/PLASTIC LAMINATE; -_, .,-,,, REFER TO ELEVATION&FINISH PLAN t - , '. • REFER TO ELEVATION&FINISH PLAN GROUP - FOR LAMINATE TYPE .... ,. , FOR LAMINATE TYPE I 1-,1-, POWER/DATA AS INDICATED; = . e 1 rr.,2-_I v II te,zeir_Z_V____01,IKV:-_I____IIILAP____i ; 1 REFER TO POWER PLAN z - 11850 SW 67TH AVE. , - z SUITE 100 . . ,i .. _ = , „ , " PORTLAND, OR z . , . CONCEALED HINGE 97223 , .. . _ , - 1 _' ri) .,. .. , CUSTOM WOOD MILLWORK WALL I V. MOUNTED V„gIV. •• :0- . 1AI I ' ARCHITECTS SAMPLE Z-CLIPS ATTACHED DIRECTLY , .,, 4 I MILLWORK - SECTION - REFRIGERATOR AT GRAB-N-GO 1 1/2” = 11-0" 2 MILLWORK - SECTION - FOOD DISPLAY AT GRAB-N-GO 1 1/2" = t ., .. TO STUD; LOCATE AS REQ'D _ • . , -,, a w / _ . , ----- -I 2X4 VERTICAL SPLIT BLOCKING FIRE WELDED CORNER ... 7-, RETARDANT TREATED AS REQUIRED --:-.. / = .1 „. ,- .• : •, :. -▪' .: ..L..... ---I SCHEDULED PARTITION; REFER TO . -. , : CONSTRUCTION PLAN FOR WALL - II `"!-• 1 ' „: .1 i'-,- , — V— I i__. , - I TYPE : - _ .7%. ADJUSTABLE 3/4"MELAMINE J •1'. : ' . .__ \ ; , ; kz SHELVES ' I I e: , k _ D. Z , i_IMAIIIV___IIIII/ III__Wat_l__IIIIIMIK_I__zi-LI.filr __z_l- : •, l•--' '''. ...- ---- DECORATIVE 1/2"SQUARE TUBE t. , ,- : -- ‘- ' „ st .; ___ .!.. CONCEALED HINGE. , STEEL; BLACKENED FINISH; i 0 w ,. - I --. I ANCHORED TO WALUBLOCKING AS _ - _ ' 1REQ'D-COORDINATE PLACEMENT& TYPE WITH ARCHITECT INTERIOR SURFACE TO BE I , ' 2▪; -.., , , • ' 3/4"MDF SHELF W/SCHEDULED PAINT ,k ....,.._ I , / „: , , , - COLOR; REFER TO ELEVATION &FINISH - i MELAMINE PLAN FOR TYP. 7,'' ADJUSTABLE 3/4"MELAMINE --it - TENANT PROVIDED TV;GC TO • t; Z / .., I IrtIAI__,I_Ill/111/IZ_Z_II.ei 4red:__I.I_Ilk.11- ___..,A ' SHELVES ; E '.- ---0--- SCHEDULED PARTITION; REFER ;.'_Itl,.r.4_, 1:-`><1 47' 1> ' I - ; PROVIDE BLOCKING AS REQ'D .. f:s .. , III____11'_WieZAZ ,iNe41 I iir#1_:_:i — TO PARTITION PLAN FOR WALL l'' I III II ,.- b '6 L.,--44 •. _-ff .- PE I ' - n / .•-• 1 , TYPE • : /,.- ....t -• SCHEDULED PARTITION; REFER TO : 1 „ CABINET BACK IS 1/2"M.D.F. - PARTITION PLAN FOR WALL TYPE : .: g: „ . , TENANT PROVIDED FLUSH MOUNT TV ADJUSTABLE 3/4"MELAMINE,Y 0 „, „ ' , ., - - '1 iL4 : BRACKET 111 : . -.: ..-- SHELVES ,•.,r- OD A/fe z Q , z, u....147,4*- zlitotz__IE__zAtrz.z.,_• _. re__-97,4-----vircwdz::: -.L. i= 1 • A: , V -'Frmr CONCEALED SHELF SUPPORT,STEEL 3/4" MDF W/PLASTIC LAMINATE; - < ' ELECTRICAL REFER TO POWER PLANS - ' .: -01 •k; ANGLE FASTEN TO VERTICAL BLOCKING; • I[ -, ' '• t; REFER TO ELEVATION&FINISH PLAN .- TYP. w> 1,---4,,_,„les FIXED 3/4"MDF SHELF W/SCHEDULED :: 1 0' - ) / . ; * --: - ; ii: FOR PLASTIC LAMINATE TYPE w :- PAINT COLOR; REFER TO ELEVATION & a , ,_-,, .:; w o . I FINISH PLAN FOR TYPE - I-- I•' - - • 2X4 VERTICAL SPLIT BLOCKING B/W cc - , _ z: ;\ , IA a -- , .., : .., :., DOOR PULL AS SCHEDULED I STUDS; FIRE RETARDANT TREATED u. _ w ,- r AS REQUIRED - - _ , 4 ,,, - , ,_ 0., ,• 1 or__I:Ilizz:nreZi]il::-..Ztillor/_747.1t1Er_:11L:_FL zr,facLzezzi:,..--A 1'-O • 3/4"MDF APRON W/MITERED CORNER z ,--_!.., 1 I I I • - .. I ,"er iork-7.7.1:sAO:NEPFHHA6IAC5.2:,0:it#11:1NOG.;c21 „ FLOATING SHELF,TYP; 3/4"MDF WI PLASTIC J ! :2 - 0 - '[:;v..4,0 ,,,,,, I mon.., 44,. Imo r ..00'-'--- --- • LAMINATE; REFER TO ELEVATION &FINISH i-= '4 I , ' . ! . < ''' Z • \ PLAN FOR PLASTIC LAMINATE'TYPE a , > ___ - 0 )\----.i . , -, . ., , - w , ., , w 17-: , This drawing is the property of Associated ..., < , w . Space Design,Inc.and is not to be , reproduced or copied in whole or part.It is , > \\\ , 0 w . ,- MITER ALL OUTSIDE CORNERS / , , I-- I _., Lu . !... cc not to be used on any other project and is to • ' " 0 w I- WELDED CORNER / _ , , u_ -- I be returned upon request Scales as stated I. i . w ce herein are for reference only as normal - ix w , 7, ` I a. a reproduction processes may alter the / L, • „ ' NOTE: ALL CABINET DOORS TO w u,i •, . T....4 W accuracy of original drawings. RECEIVE RUBBER BUMPERS I ,- • ) u ' L\ ' ., . I -. - Associated Space Design, Inc.2016 J , - — DECORATIVE 1/2"SQUARE TUBE -771- STEEL; BLACKENED FINISH; ,,, i ,,1 / „ „ HEAVY-DUTY SHELF PINS PAINTED TO -- - ANCHORED TO WALUBLOCKING AS 7 S . .• MATCH SELF,TYP. I I I REQ'D-COORDINATE PLACEMENT& '' , - " ,- I TYPE WITH ARCHITECT \ ..) ---. , , I 1 t =,,L. I =-' Lir- _ , „ . 1 :,,,.; SCHEDULED EQUIPMENT : ga. TT rI - Fr ' . n I . , ,_ , . I 7 , w- 7:, B- a , , , i Lit - I L ... rat l_=- , . . ..-. • ,- I - , > . 7-1 , , ..... 3/4"MDF W/PLASTIC LAMINATE; --‘1r1-7 Z-CLIPS ATTACHED DIRECTLY a t REFER TO ELEVATION&FINISH PLAN,, '. FOR LAMINATE TYPE • ' -rri TO STUD; LOCATE AS REQ'D w -- I _, :- I ,, ,,.„ • 0 07.01.19 ISSUED FOR PERMIT , , • \ ; -.-/ . NO: DATE: REMARKS: ' - = POWER/DATA AS INDICATED; . ! : I - I REFER TO POWER PLAN REVISIONS: , •7(-----------------------------:,-----=----,------- -': ,i 1 BLOCKING AS REQUIRED I 1 -, ) --- , DRAWING TITLE: , — — --] . in ,-:141, \/ " I .- MILLWORK SECTIONS & , Y--- /- I- ft .. ,,,, __. / I BASE BLOCKING - , a w ,„ DECORATIVE 1/2"SQUARE TUBE DETAILS CONTINUED m --- BASE,SCRIBE BASE TO FLOOR II . -- STEEL; BLACKENED FINISH; < . --, ANCHORED TO WALUBLOCKING AS PROJECT NO.: ISSUE DATE: e REFER TO PLAN - REQ'D-COORDINATE PLACEMENT& T— . • ' 28021.00 07.01.19 45 TYPE WITH ARCHITECT _ REFER TO PLAN I I DRAWN BY: CHECKED BY: ' • - _-_ I-- , -.,- /- . HF AR 7 ' E; •• • I I SHEET NUMBER: CN1 I 7 I DETAIL: WOOD WALL W/ TV 1 1/2" = V-0" 5 I MILLWORK - SECTION - BOOKCASE 1 1/2" = V-0" 3 I MILLWORK - SECTION - WATER MACHINE 1 1/2" = V-0" 1 I MILLWORK - SECTION - SHELVES W/ METAL DETAIL 1 1/2" = V-0" A7. 1 3 r\i r-- IIIIMIIIII a II I I • I I 1111111111111 5/8"GYP ON 3 5/8"METAL STUDS 5/8"GYP ON 3 5/8"METAL STUDS / \ 5 1/2" _ _ _ _ ,ASD SI(Y ,. . ._ _ __ _ ___ _ _ ,-r— I I , .,1t -17. `ice.:. '' . - Iv-S.T,:Y._ „ i� ,I. 7.-. , I. ::- - •.V .7' / i\ -►.•I Y.LI....I ..; . .7', :I I IT ' :j 1 i �I 51/2" il . I I I I1 !!:I I I s 1. II — — f II I I 1 F / 1 i i' 1 ! / V ! 1 / / 11 / / II / / 11 / / 1 / / / I I / / II / % l I / / II / l I / / l l 1 / 1 1 / / ------- :4t�._- 9.._ --_--- _---=-'-_ .,,. - - _• - • 1 irif--- A i+) I` 920 SW 6th Avenue 12th Floor ALIGN Portland, OR CUSTOM WOOD MILLWORK WALL MOUNTED / SOLID SURFACE COUNTERTOP(2CM); 3/4"MDF PANEL W/1/8"THICK BLACK T 678.491 ,3773 ON Z-CLIPS-MATCH ARCHITECTS SAMPLE SCRIBE TO WALL. REFER TO METAL FLAT BARSTOCK TRIM ALONG ELEVATIONS AND FINISH SCHEDULE ENTIRE TOP AND BOTTOM EDGE; www.asdsky.com FOR SPECS REFER TO ELEVATION FOR PAINT COLOR 7'-01/2" 5'-0" 7'-5" - - 5 I DETAIL: RECEPTION COFFEE BAR 1 1/2" = 11-0" THE PARTNERS GROUP 7 f` `\/ I► ( 11850 SW 67TH AVE. I 1I I I . I SUITE 100 !, i l I PORTLAND, OR I 1 . _ _I I I - - - - _ - - _ - - - _... _j -I 97223 I �- 1 JI 10'-0"AFF — — — - — — — i I: - -._ - — — - — — —II - I — _ - - — -- 10'0"AFF ... 10' 0"AFF �_ 10' 0"AFF I, : 8.0. DRYWALL \ I I. iv B.O.DRYWALL N j I Iv B.O.DRYWALL 1 j I B.O. DRYWALL` \ / / °— _ — I I_ — — — / I , I I I i i CUSTOM WOOD MILLWORK WALL i �i I CUSTOM WOOD MILLWORK WALL I I I I I ( MOUNTED ON Z-CLIPS-MATCH I I MOUNTED ON Z-CLIPS-MATCH ) I II I { I ' ARCHITECTS SAMPLE I 1' ARCHITECTS SAMPLE I 1 I I J 11 I ) j / I I I I, CUSTOM WOOD MILLWORK WALL / 'I i I, CUSTOM WOOD MILLWORK WALL ..i1 I ( ( 1 j ., I j MOUNTED ON Z-CLIPS-MATCH / j I MOUNTED ON Z-CLIPS-MATCH ,r, i 1 I- Z-CLIPS ATTACHED DIRECTLY r I Z-CLIPS ATTACHED DIRECTLY b ! I I ARCHITECTS SAMPLE - I I: ARCHITECTS SAMPLE I j I TO STUD;LOCATE AS REQ'D •1• TO STUD; LOCATE AS REQ'D I I I 1 ( I i I �, N I I 1 I ! I l 1j j iI I t. I zI - — — — -I / / I - - - - -I I - 1 . - j I I- - I -'1 I Z-CLIPS ATTACHED DIRECTLY I — J Z-CLIPS ATTACHED DIRECTLY - I j I I 1I- — -- _ -. -` I TO STUD; LOCATE AS REQD i — 1= - —. i I TO STUD; LOCATE AS REQ'D / I j / I I I �' / 0 j : / I - I ( ( 118"THICK BLACK METAL FLAT BARSTOCK j � I : 1"X 1/2"BLACK METAL ANGLE ANCHORED ' ' \ , 1"X 1/2"BLACK METAL ANGLE ANCHORED I t, '`l I: TO BLOCKING TO HOLD SOLID SURFACE c., : -I TO BLOCKING TO HOLD SOLID SURFACE I 1 -1 1/2' i - IN PLACE IN PLACE_ED FIXTURE I ( I - ( 3/4"MDF PANEL MOUNTED ON Z- CO 1'-1 112" j I 1" I I T CLIPS; REFER TO ELEVATION FOR r • I I I \ T- I • PAINT COLOR � I -•-I SCHEDULED FIXTURE �I I I I l I 1 I - / i ( _� I 1/2"PLYWOOD SUBSTRATE .•. [. 1/2"PLYWOOD SUBSTRATE I i I I L Z-CLIPS ATTACHED DIRECTLY TO :: _- j -1 �': 1 I I ( I - r I I STUD; LOCATE AS REQD f.I I I I I = I I 1 - I I - _' ( 1 ' I I I TENANT PROVIDED TV;GC TO ;) I? • I I I I �� 1 PROVIDE BLOCKING AS REQ'D ''-I I. - I I I i' I I I SOLID SURFACE BACKSPLASH (2CM) -_�I-- SOLID SURFACE BACKSPLASH(2CM) I I I j '•^1 1'- ADHERED TO SUBSTRATE BEYOND; REFER - ADHERED TO SUBSTRATE BEYOND; REFER I f f I 1 j Y TO MANUFACTURERS REQUIREMENTS; ( TO MANUFACTURERS REQUIREMENTS; I ',. I I I I PROVIDE BLOCKING AS REQ'D = PROVIDE BLOCKING AS REQ'D / I . j _ I i I =1 I = I ; ' I i �- ! = 3/8"TEMPERED GLASS SHELF E .• 3/8"TEMPERED GLASS SHELF I I I / 1 1 j * ! I 1 TENANT PROVIDED FLUSH MOUNT TV ) 7 •'.--II I % I �, j I I I _ I I I BRACKET 1 I r._ I. ,_ N `. 'USFi'!�A.REMIJNG '� . vet 1 ( - in I j I' ELECTRICAL; REFER TO POWER PLANS SLOTMOUNTSTANDOFF FOR 3/ "PANELS - CRL SLOT MOUNT STANDOFF FOR 3/8"PANELS 6526 /, I l: � CRLS O 0 8 ( I i BLACK FINISH;SM38MBL; PROVIDE BLOCKING AS I F BLACK FINISH;SM38MBL; PROVIDE BLOCKING A: ,. ,�' s I I I:: I I t ,f I:_ REQD I ® t b REQD j SAN F FtAhtC1SCC?. , t C� "i I I: =1 318 TEMPERED GLASS SHELF -_H • 3/8 TEMPERED GLASS SHELF i I 1 . (_ 4 I � 1 I : 7 :�_I I gar•> ' I I I 1 I I I � I - I I I II h �• . - j I I I I I k: \ " El .: CRL SLOT MOUNT STANDOFF FOR 318 PANELS CRL SLOT MOUNT STANDOFF FOR 3/8"PANELS / I I { I 1 - ( ' I I • =1 1 : BLACK FINISH;SM38MBL; PROVIDE BLOCKING AS I • -I 1- BLACK FINISH; SM38MBL; PROVIDE BLOCKING A= / I I IMIIIMI . \/ ''''' \ - 1 "-------k 20 GA. 2 112" RUNNER STUDS r- \\ \ ATTACHED TO STRUCTURE \ 12 GA HANGER WIRE �, - ,- 20 GA. 2 112" METAL STUDS \ \ ATTACHED TO STRUCTURE 1 1 -- ---� GYP. BOARD • - PROVIDE KICKERS AS REQUIRE • • -r- / MAIN OR CROSS RUNNER a \ ANGLE SPACER WINOTCWES AT ASD SKY \ RUNNER ONLY W/HORIZ. 6D. \ 318"CLR. RING SHANK NAIL(PLACE HEAD r - (I . ..:1 518" GYPSUM BOARD \ / / TOWARD CENTER OF SPAN OR Zfl ON 2 112• " METAL \„/ ,/- r — I / SPACER • STUDS - BERC 2 CLIP WITH 3/4" 1�����llmlilliiiiiiiiiiiriil : IIuIIhlimFlul iIiIiilIiCLEARANCE ON ATTACHED 4 �1 WALLS I I I I I I i I - 518" GYPSUM BOARD \— �HEIGHTAFF I I I I I. Y' ;= - - WALL ANGLE WI#10 S.M.S. TEAR AWAY 'L' BEAD W/2 112" METAL WALL ANGLE WI#10 S.M.S. SCREW AT WALL STUD, DO B.O. CEILING - SCREW AT EACH STUD AND :• REFER TO RCP STUDS, AS REQUIRED NOT FASTEN TO GRID 118" POP RIVET TO GRID ;`\ ACOUSTICAL TILE - -- SCHEDULED CEILING SYSTEM; FIXED END FREE END - • REFER TO RCP - - • 1. 8" OR WITHIN 1/4 OF THE LENGTH OF 920 SW 6th Avenue THE END TEE, WHICH EVER IS LEAST. • °' �- • -- BLOCKING AS REQUIRED 12th Floor a I� CORNER MOLDING Portland, OR - • SPACER MAY BE SLOTTED CHANNEL -�: SCHEDULED PARTITION; 1. (SHOWN) OR ANGLE W/"DIAMOND POINTS" NOTE: T 678.491 .3773 REFER TO CONSTRUCTION _ A A • • • OF SPRING STEEL WHICH SNAP TIGHT TO i_AHEIGHT AFF - ", _• - ::., PLAN PREVENT MOVEMENT OF SPACER � � CEILINGS TO COMPLY WITH ASCE 7-05 WWW.aSd51(y.00i11 SECTION 13.5.6.2.2 REFER TO RCP - - 518" GYPSUM BOARD SOFFIT WI CEILINGS TO COMPLY WITH SEISMIC BA. SOFFIT -: \ • 2 112" METAL STUDS, AS REQ'D DESIGN CATEGORY D 518" GYPSUM BOARD SOFFIT ... ___-• -- - MAIN OR CROSS RUNNER ON 2 112" METAL STUDS - V - SCHEDULED PARTITION; REFER TO CONSTRUCTION PLAN FOR CORNER MOLDING WALL TYPES 12 1 FLOATING SOFFIT 3" = 1-0" 8 I DROPPED DRYWALL SOFFIT 3" = 1-0" 4 I LAY-IN CEILING TILE DETAILS (ARMSTRONG SEISMIC RX SUSP. SYST.) / ' 4' - 0" 4' - 0" 6'-0" MAX.TO • 20 GA. 2 1/2" RUNNER STUDS; ATTACHED TO 1ST BRACE ` STRUCTURE 1 �/��//�����////// - B.O. STRUCTURE ABOVE \ / \ a - WALL LINE 4 � - CABLES ATTACHED TO STRUCTURE ABOVE \ PROVIDE KICKERS AS NEEDED\ t N ! 1 / / \ \ 0 3 V // \ / - -- VERTICAL SUPPORT- 12 GA. WIRE @ 4'-0" O.C. EACH WAY THE \ \ o MAX. • \ , l N 2 TYP. • COMPRESSION STRUT HANGER WIRE THROUGH 314" \/ o • —, / EMT. DIAGONAL BRACING- SPLAYED 12 GA. WIRES AT PARTNERS - LFILZFELT STANDARD SUSPENSION / 12'-0" O.C. EACH WAY, LATERAL BRACING 6'-0" FROM HARDWARE o _ _/ WALL. 12'-0" FROM CENTER. GROUP \ N - / INTERMEDIATE RUNNERS @ 4'-O" O.C. - 518" GYPSUM BOARD CEILING � ` WI 2 112" METAL STUDS, A5 • / REQ'D N.T _ i CROSS RUNNERS 4'-0" O.C. SCHEDULED LIGHT 1 1 FIXTURE \ \ / ADDITIONAL CROSS "T" 11850 SW 67TH AVE. BARS @ 2'X2' CEILING. TYP. SUITE 100 I - 1" FELT PANEL - i/ \__:::: / MAIN RUNNERS @ 4'-0" O.C. PORTLAND, OR 9 1 �' / 97223 i ������������ � , . .. ���� HEIGHT AFF `; 111 B.O. CEILING NOTE: 1. 4 WAY 45° DIAG. 12 GA. WIRE BRACING @ 12'-0" �i N APPLIED FELT; REFER TO CEILING PLAN & FINISH NON-BEARING PARTITIONS THAT TERMINATE AT A EACH WAY. ATTACH EACH WIRE TO "T" BAR SCHEDULE FOR MORE INFORMATION SUSPENDED CEILING AND ARE LATERALLY W14 TIGHT TURNS IN 1-112" BRACED IN ACCORDANCE WITH REQUIRED 2. 12 GA. VERTICAL HANGER WIRE @ 12" O.C. DETAILS MAY BE CONSIDERED AS NOT ADDING TO EACH WAY W/3 TIGHT TURNS. CORNER MOLDING THE LATERAL LOAD REQUIRED TO BE RESISTED 3. 1" CONDUIT COMPRESSION STRUT @ 12'-0" BY THE CEILING SYSTEM. O.C. EACH WAY. SEE TYP. COMPRESSION STRUT DETAIL 1/-A7.21 11 I CEILING DETAIL @ FELT PANELS 3" = 1 '-0" 7 I DRYWALL TO FELT TRANSITION 3" = 1 '-0" 3 1 TYPICAL SUSPENDED CEILING BRACING N.T.S. j• SAFETY OR SUPPORT WIRE. ALL CABLE TO BE 12 GA. REFER TO DETAIL 1 . 11- FOR ATTACHMENT TO STRUCTURE ABOVE. • I 20 GA. 2 112" RUNNER eRECESSED FLUORESCENT LIGHT FIXTURE �� --- B.O. STRUCTURE ABOVE STUDS ATTACHED TO 3,,Z- -_____________ STRUCTURE 400 - --- - CABLES ATTACHED TO STRUCTURE ABOVE 60° MAX. 2 PROVIDE KICKERS AS NEEDED 4$` /� \ \ 45°. ., PROVIDE T BAR HOLD V DOWN AT EACH CORNER, 15116" PRELUDE SUSPENSION SYSTEM . ! TYP. • ,,,./- GRID • • GRID RUNNER @ 4'-0" O.C. 5 •_ SCHEDULED LIGHT • FIXTURE ! NOTES: 1. ONE 12 GA. CABLE FROM EACH CORNER OF THE FIXTURE VERTICALLY TO THE ROOF 1-112"TECTUM CLOUD SCHEDULED CEILING OF THE STRUCTURE. r--.... ._,----------- FOR TYPE REFER TO RCP 2. FROM TWO DIAGONALLY OPPOSITE CORNERS OF THE FIXTURE ONE CABLE TO THE ‘71c D n n STRUCTURE ABOVE AT 45°ALONG THE LENGTH OF THE FIXTURE AND ONE CABLE TO ��.t. `� ZD THE STRUCTURE ABOVE ALONG THE WIDTH OF THE FIXTURE. PLACEMENT OF CABLES ...._4+-C1/ ♦. `�.♦, ..` ,. ♦. SHALL BE SUCH THAT TERMINATION AT THE ROOF STRUCTURE ARE ABOVE FIXTURE ' '"�' REMLSNG �'► HEIGHT AFF ► I 1'1"1 6526 r-,I B.O. CEILING i 3. FROM TWO DIAGONALLY OPPOSITE CORNERS OF THE FIXTURE, ONE SLACK#12 GA. EQ EQ I I I I I I I I I I I II SAFETY WIRE. ATTACH TO STRUCTURE WITH PHILIPS REDHEAD 5/16" DIA X 1-1/2" LONG *� SAN FRANCISCO i i / MIN. EMBEDMENT 1-112":. LOOP WIRE THROUGH HOLE AT REDHEAD AND FASTEN WITH CA NOTE: INSULATED OVERLAP TYPE SPLICE TUBE; T& B#ZE-8-7 CRIMPED WITH TOOL AS . N CEILING TO COMPLY WITH ASCE 7-05 RECOMMENDED BY SUPPLIER. 'O REFER = �.Jl- SECTION 13.5.6.2.2 TO RCP �. 4. ATTACH 118"THREADED EYEHOOK TO EACH SIDE OF FIXTURE HOUSING WITH LOCK CORNER MOLDING WASHER AND NUT. LOOP SLACK WIRE THROUGH EYEHOOK. 518" GYPSUM BOARD CEILING WI 5. MECHANICAL DIFFUSER GRILLES WILL BE BRACED SIMILAR TO LIGHTING FIXTURES 2 1/2" METAL STUDS, AS REQ'D WITH TWO #12 GA. WIRES FROM DIAGONALLY BRACES CORNERS SEE NOTE 2 This drawing is the property of Associated Space Design, Inc. and is not to be 10 I CEILING DETAIL @ TECTUM CLOUD 3" = 1 '-0" 6 1 DRYWALL CEILING TO ACT 3" = 1 '-0" 2 1 DETAIL @ SUSP.FIXTURES N.T.S. reproduced or copied in whole or part. Itis not to be used on any other project and is to - be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the 'i + - METAL DECK accuracy of original drawings. - Associated Space Design, Inc. 2016 PROVIDE ONE COMPRESSION STRUT HEIGHT AFF 114" DIA. EXPANSION FOR EVERY 144 SF OF CLG. WITH MAX. BOLTS SPACING OF 12'-0" O.C. (LENGTH NIVB.O. STRUCTURE EQUALS CENTER OF BOLTS). USE 112" EMT. FOR LENGTHS TO 3'-9"; USE 314" • :"MAX FR0' WALL EMT. FOR LENGTHS 3'-9"TO 5-10". PROVIDE AIRCRAFT CABLE @ ATTACHED METAL STUD TO STRUCTURE , - -- rt- 8'-0" O.C., ATTACHED TO ROD -. -. SPACER12 GA. GALVANIZED STEEL WIRE SPLAY /� ; 4 WAYS. PLACE AT 45°, SECURE TO SLAB — - n i v '� ATTACHED CABLE TO STRUCTURE ,1111°' ABOVE. i i 14 - 314" X 1 112" BATTEN STRIPS :1:O:I::NER @ 4WHITE) @ 4'-0" O.C. ATTACHED BATTENS TO • SCHEDULED CEILING WOOD PLANKS W/FINISH iI SYSTEM; REFER TO RCP r /...iv_•/' NAILS I - --� -... - . I / NOTE: 0 07.01.19 ISSUED FOR PERMIT -- - - (2) 314" LIGHT WEIGHT MDF f'. r-: ,,;.-,; •, Ill I I 1 1 I I HEIGHT AFF FIXTURES WEIGHT 20#OR MORE, NO. DATE: REMARKS: PANELS, GLUE TOGETHER I B.O. CEILING CONNECT 2- 12 GA. FIXTURE SUPPORT REVISIONS: FOR WOOD PLANKING W/ 2" 3"MAX. WIRES AT DIAGONAL CORNERS OF Zo PLASTIC LAMINATE ON ALL - WALL ANGLE MOLDING - EACH FIXTURE THREE FULL WRAPS. DRAWING TITLE: EXPOSED FACES; REFER TO DRYWALL CORNER MOLDING MINIMUM FIXTURE SUPPORT WIRES CEILING SECTIONS & RCP FOR LAMINATE TYPE SUPPLIED AND HUNG BY T-BAR L - ALIGN CONTRACTOR. MAX. FIXTURE WEIGHT DETAILS MAIN RUNNER @ 4'-0" O.C. 55#. Q -- -- - SCHEDULED CEILING SYSTEM; REFER TO RCP EXTEND TUBE TO BE TIGHT TO PROJECT NO,: ISSUE DATE: co CEILING GRID AND STRUCTURE .- ABOVE, ABOVE, THEN INSTALL BOLT TO 28021.00 07.01.19 cfl 1 112" REFER TO RCP 1 112" SECURE ONE TUBE TO THE OTHER. DRAWN BY: CHECKED BY: A- - - TUBES SHALL LAP ONE ANOTHER AT LEAST 4" IN FULLY EXTENDED SL AR 0) POSITION. SHEET NUMBER- p N 9 1 CEILING DETAIL - SUSPENDED WOOD BAFFLES 3" = 1 '-0" 5 1 DRYWALL CEILING TO ACT, FLUSH 3" = 1 '-0" 1 I TYPICAL CEILING BRACING N.T.S. A7 .21 N. 1 I I ASD SKY 920 SW 6th Avenue 12th Floor Portland, OR T 678.491 .3773 www.asdsky.com THE PARTNERS GROUP 11850 SW 67TH AVE. SUITE 100 PORTLAND, OR 97223 ALIGN CENTERLINE OF TOP OF TRANS. STRIP W/CENTERLINE OF DOOR j SCHEDULED DOOR MAY OCCUR; REFER TO DOOR SCHEDULE — — — — — SCHEDULED VCT FLOOR; REFER TO FINISH PLAN FOR TYPE ADA APPROVED VINYL TRANSITION STRIP; COLOR: �. r TBD • r - SCHEDULED CARPET; l' REFER TO FINISH PLAN FOR _, ., ..r _ TYPE r ........1. 'UJ'!/,','.,, I i,. .I _;: K II1i)I)WkRI4h14iI�J 1//11/l con 2 FINISH - VCT TO CARPET FLOOR TRANSITION 6" = 1-0" COSI � A R IrI>.,Ir� �� 6526 �..I di,AN F I4ANGISC0. 'E�QI�O� This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2016 SCHEDULED SEALED CONCRETE FLOOR, REFER TO FINISH PLAN/ , ANODIZED ALUMINUM SCHLUTER STRIP, SCHIENE-AE - BLACK FINISH ! SCHEDULED CARPET; REFER TO —_ — FINISH PLAN FOR TYPE — —_ — N �\ `ii ll.t'i ' '', I,', I'. i ,l, .I — SLOPE UNDERBED FILL AS REQ'D TO - - - INSTALL TRANSITION STRIP ' - EXISTING CONC SLAB 0 07.01.19 ISSUED FOR PERMIT NO: DATE: REMARKS: REVISIONS: DRAWING TITLE: FINISH MATERIAL DETAILS 2 Q PROJECT NO.: ISSUE DATE: 0 28021.00 07.01.19 DRAWN BY CHECKED BY: N— N-- HF — HF AR cs, SHEET NUMBER: p N 1 I FINISH - SEALED CONCRETE TO CARPET TRANSITION 3" = 1 '-0" A7 .41 I I MIMI _ L V.I.F. 6'-0" )1 V.I.F. t3'-0" tVERIFY W/SCHEDULE t 1I. 6'-0" _, 1_. \ / \ �c----- 7- ��— /� / \ / / \ / \ / \ AD SKY / / \ / \ / \ / / \ / \ / \ / / \ / \ / \ / / \ / \ / \ %,,,v _ / - / \ b / \ o _ / o / \ / \ rn // // // / // `' \ \ / -I \ / \ / °0 \ `° \ c / \ / \ / \ \ / \ / \ / \ \ / \ / \ / \ \ / \ / \ / \ \ / \ / \ / \ \ / \ / \ / \ . 920 SW 6th Avenue 12th Floor DOOR TYPE"1" DOOR TYPE"2" DOOR TYPE"3" DOOR TYPE"4" Portland, OR SOLID CORE,STAIN GRADE SOLID CORE, STAIN GRADE FRAMELESS SOLID CORE,PAINT (PAIR)FRAMELESS T 678.491 .3773 DOOR; STAIN TO MATCH DOUBLE DOOR; STAIN TO GRADE DOUBLE DOOR; PAINT TO GLASS DOORS& www.asdsky.com EXISTING BASE BUILDING MATCH EXISTING/RELOCATED MATCH ADJACENT WALL COLOR, SEMI- SIDELITES MULTI-TENANT DOOR TENANT DOORS GLOSS I 5 I DOOR TYPES 3/8" = 1 '-0" FIRE DOOR TYPE DESCRIPTION RATING DOOR MATERIAL DOOR FINISH FRAME MATERIAL FRAME FINISH COMMENTS 1 3'-0" X 8'-0" X 1 3/4" NR SC STAIN AL BLK AL DOOR & FRAME STAIN / FINISH TO MATCH BUILDING STANDARD MULTI-TENANT CORRIDOR DOOR 2 5'-0" X 8'-0" X 1 3/4" NR SC STAIN* AL BLK AL DOOR STAIN TO MATCH EXISTING / RELOCATED TENANT TH E DOORS IN SUITE 3 5'-0"X 8'-O" X 1 3/4" NR SC PT - - DOUBLE FRAMELESS/ HIDDEN PIVOT DOORS, PAINTED TO PARTNERS MATCH ADJACENT WALL 14 6-0" X 9'-O" X 1/2" NR GLASS - - - DOUBLE FRAMELESS GLASS PIVOT DOORS I GROUP - 1E1 1 EXISTING DOOR/FRAME TO REMAIN - - - - - I R1 13'-0" X 8'-0" X 1 3/4" NR SC STAIN* AL BLK AL RELOCATED DOOR; NEW FRAME I R2 13'-0" X 8'-O" X 1 3/4" NR SC STAIN* AL BLK AL RELOCATED DOOR; NEW FRAME W/ADJACENT SIDELIGHT I 11850 SW 67TH AVE. SUITE 100 4 DOOR SCHEDULE PORTLAND, OR 97223 t +1-6" t A8-1 'PRICE AS ADD ALTERNATE:TO REFINISH/PROVIDE NEW STAIN COLOR FOR EXISTING DOORS TO BE REUSED/RELOCATED. l �O ., (2)2 1/2"20 GA METAL STUDS \ • BRACED TO STRUCTURE '- ABOVE \ KICKERS AS REQUIRED 3 ALTERNATES ,- \„ G,' � � 1/2"THK FRT HEADER AS REQUIRED ABBREVIATIONS: c) IL '., CONCEALED CLOSER AL ALUMINUM j o o ADJ ADJACENT —� - U I I I I ( 1 IL �. w_�y - - CORNER BEAD,TYP. BLK SATIN BLACK PAINTED FINISH BLK AL BLACK ALUMINUM-FACTORY FINISH iiE DENOTES EXISTING DOOR TO REMAIN =; i HC HOLLOW CORE ' HM HOLLOW METAL `______ N NEW TOP PATCH FITTING NR NOT RATED PT PAINTED FINISH, SEE FINISH PLAN NOTES R DENOTES EXISTING DOOR TO BE REUSED BUTT HINGE SC SOLID CORE SS STAINLESS STEEL ,k SCHEDULED WOOD DOOR T TEMPERED SAFETY GLAZING,3/8"THICK U.N.O. V WD WOOD 1 1/2"PROFILE ALUMINUM I V FRAME j —c PARTITION BEYOND ... _ _ _ _ _ FINISH: BLACK NOTES: w;: 1.ALL FRAMES TO BE RACO SOLUTION II 487 ALUMINUM FRAME, 1 1/2"PROFILE, BLACK FACTORY FINISH 1/2"THK CLEAR TEMPERED ` .I i - ' GLASS N3-001 487_1.5INCH_DOOR-HEAD AT-DRYWALL `' t! �, ^ <> N3-003_487_1.5 INCH_HINGE-JAMB N3-005_487_1.5 INCH STRIKE-JAMB_AT-GLASS ) n 2.ALL LOCK SET CORES SHALL BE COMPATIBLE WITH THE BASE BUILDING STANDARD. KEYING REQUIREMENTS SHOULD BE COORDINATED WITH THE TENANT AND LANDLORD PRIOR TO ORDERING HARDWARE. zt,,_ :,,:,:-. '.-:,,,,;.-::-: 3. DENOTATIONS: = ( I + "E"DENOTES AN EXISTING DOOR TO BE REMAIN BOTTOM PATCH FITTING SCHEDULED PARTITION "R"DENOTES AN EXISTING DOOR TO BE REUSED �Ir' FLOOR PIVOT 4.ALL HARDWARE SHALL MATCH EXISTING UNO ili � THRESHOLD MAY OCCUR 5.ALL DOORS REQUIRING A CARD READER(CR)OR DOOR MANAGEMENT ALARM (DMA)SHALL RECEIVE A DOOR CLOSER. _�; � -- Y• 6.ALL GLASS SIDELIGHTS SHALL HAVE 3/8"TEMPERED GLASS, U.N.O. z Y 7.ALL MAGNETIC AND ELECTRIFIED LOCKS SHALL BE TIED INTO THE BUILDING FIRE ALARM SYSTEM. � " 8. HARDWARE AT ALL EGRESS DOORS SHALL BE READILY OPENED FROM THE EGRESS SIDE,WITHOUT THE USE OF KEY, SPECIAL KNOWLEDGE,OR EFFORT IN COMPLIANCE WITH IBC 1008.1.9. d(3,Eh!� -RESILING "' W+ 6526 .�. 2 SECTION - HERCULITE GLASS DOOR 3 = 1 -0 7 DOOR - ALUMINUM DOOR JAMB 3 = 1 -0 2 ABBREVIATIONS AND NOTES ' ca tscca. . MANUFACTURER OR BUILDING MANUFACTURER OR BUILDING SET DESCRIPTION ITEMS FINISH STANDARD SET DESCRIPTION ITEMS FINISH STANDARD i:,.1 2 1/2"20 GA METAL STUDS IA STANDARD PASSAGE SET BUTT HINGES 626 4 1/2"X 4 1/2" CARD READER PROVIDED AND INSTALLED BY SEC. BRACED TO STRUCTURE MORTISE LOCKSET SET WITH LEVER 626 MATCH EXISTING VENDOR This drawing is the property of Associated ABOVE (PASSAGE FUNCTION) Space Design,Inc.and is not to be ..=` I FLOOR STOP 626 ROCKWOOD 446 165 DOUBLE CLOSET DOORS BUTT HINGES 626 4 1/2"X 4 1/2" reproduced or copied in whole or part.It is SILENCER CLEAR LOCKSET WITH LEVER(STORAGE 626 MATCH EXISTING not to be used on any other project and is to ��' be herein are forned r efen quest rence onlyles as as normal stated FUNCTION) SCHEDULED PARTITION I B1 STANDARD LOCKSET BUTT HINGES 626 4 1/2"X 4 1/2" I DUMMY TRIM 626 reproduction processes may alter the y STORAGE ROOM MORTISE LOCKSET WITH LEVER 626 MATCH EXISTING ( TOP&BOTTOM FLUSH BOLT 626 accuracy of original drawings. FRT BLOCKING AS REQUIRED (STORAGE FUNCTION) I DUST PROOF STRIKE 626 Associated Space Design,Inc.2016 ,} �` ( FLOOR STOP 626 ROCKWOOD 446 I SILENCER CLEAR �.` = SILENCER CLEAR e ,. ,. R4 SURFACE CLOSER 626 LCN 4040 OR EQUAL;MOUNTED I B6 HIDDEN DOUBLE DOORS CENTER HUNG PIVOT HINGES 1626 I RIXSON OR EQUAL INSIDE OF ROOM I FLUSH FITTING PULL-OUT EDGE PULL 1626 I I -- CEILING SYSTEM; SEE _ `b' ROLLER DOOR CATCH 626 INSTALLED FLUSH AT CONCEALED B2 WELLNESS ROOM PRIVACY BUTT HINGES 626 4 1/2"X 4 1/2" WOOD HEADER I ( I 74 1 Ef� REFLECTED CEILING PLAN II j 1 j I j I j II '; °>j I I j 1 j 1 DOOR W/"OCCUPIED" MORTISE LOCKSET WITH LEVER 626 MATCH EXISTING MAGNETIC STOP 1626 INSTALLED AT HEADER � x.,..,. L FOR LOCATION AND TYPE I I FLOOR LOCK 1626 i .a (PRIVACY FUNCTION) : ='.� CORNER BEAD,TYP. w CEILING SYSTEM; SEE INDICATOR FLOOR STOP 626 ROCKWOOD 446 0REFLECTED CEILING PLAN FOR SILENCER CLEAR G1 DOUBLE GLASS DOORS W/ CENTER HUNG PIVOT HINGES 626 z %'`I C., _ LOCATION AND TYPE I 1I I w IL '� �.-+i SURFACE CLOSER 626 LCN 4040 OR EQUAL;MOUNTED I CARD READER 1 DOUBLE SIDED DOOR PULL(EA.) 1626 ROCKWOOD RM3301 MP(60"LONG) 1 1/2"PROFILE ALUMINUM FRAME INSIDE OF ROOM 1 1/2"RECESSED ALUMINUM g g j I (FAIL SAFE) TOP&BOTTOM PATCH FITTINGS 1626 DORMA(STAINLESS STEEL) CHANNEL W/NEOPRENECONCEALED CLOSER(EA.) 626 DORMA RTS-88 W/90 DEGREE .f / B3 SINGLE DOOR W/ BUTT HINGES(1 ELECTRIFIED) 626 4 1/2"X 41/2" ( HOLD-OPEN w zCARD READER MORTISE LOCKSET SET WITH LEVER 626 MATCH EXISTING GASKET a z< 7/7 1 I I 1 FLOOR STOP 1626 ROCKWOOD 446 P j O rO U / (FAIL SAFE) ELECTRIC STRIKE I MAG LOCK(EA) PROVIDED AND INSTALLED BY SEC. V O 0 (FLOOR STOP 626 ROCKWOOD 446 I VENDOR I SILENCER CLEAR I CARD READER PROVIDED AND INSTALLED BY SEC. ,°\ z ( 7/7I SURFACE CLOSER 626 LCN 4040 OR EQUAL,W/90 DEGREE VENDOR SCHEDULED WOOD DOOR HOLD-OPEN;MOUNTED INSIDE OF PUSH BUTTON RELEASE PROVIDED AND INSTALLED BY SEC. 0 07.01.19 ISSUED FOR PERMIT PARTITION BEYOND U w f ROOM VENDOR NO: DATE: REMARKS: ii CARD READER PROVIDED AND INSTALLED BY SEC. CEILING-MOUNTED MOTION SENSOR PROVIDED AND INSTALLED BY SEC. 7 —■ / ALUMINUM FRAME BEYOND VENDOR VENDOR REVISIONS: 1/2"THK CLEAR TEMPERED z GLASS w7/0 I B4 1 SINGLE DOOR W/ BUTT HINGES(1 ELECTRIFIED) 1626 4 1/2"X 4 1/2" I H1 RELOCATED LEVER W/LOCKSET 1 i I DRAWING TITLE: SCHEDULED FLOOR CARD READER MORTISE LOCKSET SET WITH LEVER 626 MATCH EXISTING I I I DOOR SCHEDULE & DOOR o / (FAIL SECURE) ELECTRIC STRIKE I TYPE DETAILS I FLOOR STOP 1626 ROCKWOOD 446 tlJ1� 4YI1 IA MI' MrIPIV1 $11��I ItN141NIPNY�i'1911111_�,' 11/4M IA A6aPdl'I,!'I N611'� Q 1 SILENCER CLEAR I PROJECT NO.: ISSUE DATE: N r — NOTE:ORDER FRAMES AND DOORS SURFACE CLOSER 626 LCN 4040 OR EQUAL;MOUNTED LONG TO ACCOMMODATE FLOOR INSIDE OF ROOM 28021.00 07.01.19 cc tA// CHANNEL FASTENED TO SLAB 1"BRUSHED ALUMINUM LEVEL AND ENSURE FRAME DETAIL DRAWN BY: CHECKED BY: r. AT CEILING IS MAINTAINED. T. AR AR a, SHEET NUMBER: p N 1 I SECTION - HERCULITE GLASS SIDELITE 3" = 1 '-0" 6 I DOOR - ALUMINUM FRAME 3" = 11-0" 1 I DOOR HARDWARE SCHEDULE A8 .O1 cv I I • B8' MIN. CORRIDOR UNDER 200 FT. DOOR APPROACHES [SECT. 118-404.2] DOOR HARDWARE [SECT. 1008.1.91 MAX. DOOR CLOSER PRESSURES THRESHOLDS [SECT. 118-404.=5 ELEVATOR LOBBY AND CAR RAIL HEIGHT ELEVATOR NOTES: ELEVATOR CONTROLS [SECT. 11B-4071 VESTIBULES [SECT. 11B-403.5 -PROVIDE THIS ] [SECT. 116-403.5] u 5 L35 INTERIOR / 2 " CLEAR @ EXT. DOORS ADDITIONAL SPACE IF 1. THE AUTOMATIC DOOR REOPENING EXTERIOR (EXT.) MEANS SUBJECT TO EXTERIOR AIR �2-8/ DOOR IS EQUIPPED 5 LBS EXTERIOR '1 1 ? CLEAR 0 INT. " 15 LBSFIRE (SEE STATE TITLE 24 HALL LANTERNS DEVICE MUST BE LOCATED VERTICALLY PRESSURES, AS IN OPEN AIR STRUCTURES. WITH BOTH A LATCH SECT. 3304.(1.2}} /; \ r CAR POSITION -� AT 5" AND 29" ABOVE THE THRESHOLD, MIN. ,�, DOORS AND CLOSER ; -10 MIN. SMOOTH OR r ASDSKY INDICATOR AND MUST BE ACTIVATED WHEN AN NOTES: L, \ \ UNINTERRUPTED BOTTOM RAIL 1 �� OR PROVIDE KICK PLATE R!' - OBJECT PASSES THROUGH EITHER OF RAISED NUMBERS AND LETTERS, WHITE 32 18' INT' 18"I NT. o ce ce "- z ' z \ / I \ EMERGENCY „O'- i ON BLACK BACKGROUND. CONTROL CLR. 24 EXT. 32 " o ¢ N z EVACUATION SIGN .�'�'� n I : THE UNES. " = CLR. 24 EXT. `L . I G DOOR CLOSER SPEED m ��7-'" �' \ "' 2. THE AREA ADJACENT AND BELOW THE BUTTONS, TO BE RAISED 1/8", SQUARE " m ,, W r W I L \ en - ) , c EXTERIOR CALL BUTTONS �3� SHOULDERS, ILLUMINATED. us ¢ S MIN. 5 SECONDS FOR DOOR GATE TO �E� CALL BUTTON SHALL BE FLAT, FLUSH - r I DOOR DOOR/ GAT _ MIN. �+ THRESHOLD: ..,� AND CLEAR OF ALL PROTRUDING z z �� � � I HARDWARE OSE FROM THE 90' POSITION TO THE " " 36 - 12' POSITION • • HEIGHT CHANGE IN LEVEL 1/4 TO 1/2 IS PERMITTED, WITH 1:2 �:,-�.•:•r- ...•........: OBJECTS. 1 z MIN• 3. IF TELEPHONE IS IN CLOSED MAX. HGT. FROM MIN. (36" FOR OCCUPANCY a! m I� COMPARTMENT, THEN DOOR MUST HAVE FLOOR TO \ MIN. \ 18" INT. LOAD LESS THAN 10) 60" MIN. 48" MIN. if, I Q �` BEVEL; GREATER CHANGE SHALL BE RAMPED 1:12. o �, (A) SIDE-OPENING DOOR LEVER OR LOOP HARDWARE, PER 3/4' BUTTON HIGHEST BUTTON 32' 18 INT. 32" 24" EXT. x 80 MIN. MINIMUM CLEAR WIDTH FOR (13 a5/8' NUMERAL 70 8 O z ,� )• r 1008.1.9.ELEVATOR MUST BE EQUIPPED WITH A 100 - , 24" EXT. Com' , : SINGLE WHEELCHAIR FRONT APPROACH a ._._..._,...._.....,.; 1-T., BRAILLE 50 6 0 44" Ml ORRIDOR O R 200 FT. SECT. CLEAR AND LEVEL P 1FORM `-4JEll CARPET PILE a DOOR REOPENING DEVICE THAT REOPENS m 44 MIN. VE [ Q UNDER NUMBERS o 11B-403.51 . ij '5..:".? \ :: DOOR WHEN OBSTRUCTED DURING O 4 O ` / / $ z CLOSING. MAIN ENIRY� 10 2 O "' m TWO DOORS IN SERIES DOORS AT OPPOSITE NOTE: Lever Toggle Push-Pull IF CARPET OR CARPET TILE IS USED ON A GROUND OR r.;y' 5. DOORS SHALL REMAIN FULLY OPEN FLOOR °� .- WALLS OPENING INWARD 48' o z I , I %zNOT: FLOOR SURFACE, THEN IT SHALL BE SECURELY 920 SW 6th Avenue :,M WHEN ANSWERING A CALL FORA „� ,y ,. ., EXCEPT PULL SIDE " ATTACHED: HAVE A FIRM CUSHION, PAD OR BACKING OR HAND-ACTIVATED LATCHING AND LOCKING DOORS " • MINIMUM OF 5 SECONDS. OCTAGON SYMBOL p O r0 � NOTE: ' I 24 Imo-7E ALONG A PATH OF TRAVEL SHALL BE OPERABLE WITH 12th Floor m o -FLOOR INDICATION ON BOTH in = ' ` 6. MUST HAVE AN AUDIBLE AND VERBAL SHALL BE RAISED, \ DOORS MAY ALSO SWING OUTWARD AT BOTH ENDS. SUCH l� � k' PERMITTED MIN. " A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC NO CUSHION OR PAD: AND HAVE A LEVEL LOOP, pO JAMBS BRAILLE TO THE LEFT • TEXTURED LOOP, LEVEL-CUT PILE OR �, ' ANNOUNCEMENT OR SIGNAL THAT BUT "X IS NOT " DOORS MUST HAVE 12` MINIMUM CLEARANCE TO THE ON PUSH y BARS, PUSH-PULL ACTIVATING BARS OR OTHER Portland, 0 R SOUNDS TO TELL THE PASSENGERS THE �' SIDE IN HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT LEVEL-CUT/UNCUT PILE TEXTURE. THE MAXIMUM PILE � •••:: ::::7:*:;::•::•= 36" ;::::::::::::::::::z:::::::::::::'•::: CAR IS STOPPING AT OR PASSING A MIN. HGT. FROM FLOOR TO PUSH/STRIKE IF THE DOOR 1S EQUPPIED WITH BOTH LATCH 60" MIN. GROUP R 24" REQUIRING THE ABILITY TO GRASP THE DOOR HEIGHT SHALL BE 1/2 INCH. T 678.491 .3773 LOWEST BUTTON ` AND CLOSER. ' - ` HARDWARE. WWW.a S CI S k}I.C O CIT MIN. I' FLS ` OCCUPANCIES IN. �( 7. AUDIBLE SIGNAL 1 BELL UP; 2 MINIMUM CLEAR WIDTH FOR PUSH SI (B) CENTER-OPENING DOOR BELLS = DOWN TWO WHEELCHAIRS www Com • , LATCH APPROACH 1 1 ELEVATOR N.T.S. 2 I PATH OF TRAVEL N.T.S. RAMPS WITH TURNING PLATFORMS WHEN DOOR SWINGS } SFE NO1E " M NFOPLUSDDOOR4WIDTH RAMP & WHEEL GUIDE DETAILS [SECT. 1010. 11B-4051 12" MIN. RAMP/STAIR HANDRAILS STAIRS [SECT. 1009. 11B-504. 11B-505] STAIR NOTES: STAIR NOSING f$ECT. 116-5041 IDENTIFICATION [SECT. 11B-703. 11B-504.81 INTERMEDIATE TURNING N01- 60 " , THE UNDERSIDES OF NOSINGS SHALL LOCATED ON STRIKE SIDE MIN. 78 60 MIN. WHEN CIRCULAR NON-CIRCULAR NOT BE ABRUPT. THE RADIUS OF N- LANDING ( }� 12' MIN. ` 50' µ1N' --"oilliIllIllMMm--- NO ONTONDINGSWINGS / iii Or A: 1 1/4" - 2" B: 1 1/2" MIN 12" CURVATURE AT THE LEADING EDGE 1 1 2" MAX. 1 1 2" MAX. 1' HT. WEST STAIR 12" µ1N SEE NO CONTINUOUS AND y OFTHE TREAD SHALL BE NO / / L_ NO ROOF ACCESS Sly 2 "\ SMOOTH GUIDE B. 1 1/2' MIN D: 4"1/46 MAX �I 'I GREATER THAN 1/2 INCH. RISERS 11 .� RAIL 2"-4" O.C. PERIMETER / \ • SHALL BE SLOPED OR THE MIN. 5' HT. 7 L_____ THE • \ k •-1/ ABOVE RAMP A B G C " HANDRAILS SHALL RETURN TO UNDERSIDE OF THE NOSING SHALL /� �6_ 1. HT B2 Thu 24 `.. V SURFACE WALL OR TERMINATE IN NEWEL V PARTNERS °p " I,� ! * 1 MAX. HAVE AN AtJGLE NO LESS THAN 60' 1� TOP PLATFORM M 27" MAX. �( D - FROM EDGE POST FROM THE HORIZONTAL. NOSINGS GRADE 2- •:•.. . ... 72` INTERMEDIATE LEVEL LANDING - OF TREAD EQ. EQ. 12" SHALL PROJECT NO MORE THAN 1 "� BRAILLE GROUP MIN. , , PROTRUDES INTO m \ m n m n ,.•, 12' MIN. x SEF NOTE T A PATH OF -, 1 \ ��, ��, f 1/2 INCHES. WATER SHALL NOT ---- 72 TRAVEL -. .��•--- MIN. 2" WIDE '� ACCUMULATE ON THE TREAD 41-\_ NO IE 2 48" MIN.; IF OCCUPANCY LOAD IS > \\ "�� r "' SOUD COLOR M SURFACE. TREAD SURFACE TO BE CHARACTER HEIGHTS ARE SUGGESTED 300, THEN 60` MIN. HANDRAIL �+ (A) {B} (C) CONTRASTING SUP RESISTANT. (a) FLUSH RISER (b) ANGLED NOSING A MINIMUM HEIGHT OF 5/8' IS ELEVATION A AND CURB STRIPEtd- ° REQUIRED. NOTE: BLOCKING REQUIRED- ,r,r NOTES: ,ILL TEXT SHALL BE TACTILE-RAISED 1 850 SW 67TH AVE. EXAMPLES OF RAMP DIMENSIONS RAMP NOTES: _� Cl2 CODE STIPULATED LOAD STAIR NOTES: THE UNDERSIDES OF NOSINGS SHALL NOT 1/32' MIN. TEXT COLOR SHALL SUITE 100 SLOPE MAX. VERTICAL RISE MAX. HORIZ. PLAN DISTANCE 1. MAXIMUM HORIZONTAL DISTANCES OF EACH :_ REQUIREMENTS FOR HANDRAILS '/ //•4; e 1. CLOSED RISERS ONLY BE ABRUPT. THE RADIUS OF CURVATURE CONTRAST VISUALLY IMTH BACKGROUND RAMP AND RUN VARY (SEE TABLE BELOW). "' (TYPICAL, EACH EXAMPLE) ' E i J 2. SUP RESISTANT TREADS AT THE LEADING EDGE OF THE TREAD 70X OR GREATER. (INCHES} BTWN. LANDINGS (FEET} 2. IF CHANGE of DIRECTION AT LANDING IS 30' A N ` -` 3. 2' WIDE SOLID CONTRAST SHALL BE NO GREATER THAN 1/2 INCH. ` PORTLAND, OR TO SUIT DESIGN ^ r,, R 1:12 30 30 OR GREATER, A 72' LEVEL LANDING IS REQUIRED M N STRIPING FOR TOP AND BOTTOM RISERS SHALL BE SLOPED OR E .I 97223 1:16 30 40 PIPE RAILING MOUNTED " M UNDERSIDE OF THE NOSING SHALL HAVE 1' HT. SANS SERIF FONT m IN EACH DIRECTION OF TRAVEL. MIN. 183 MIN. TREAD ON INTERIOR STAIRS, ALL AN ANGLE NO LESS THAN 60' FROM THE (CAPITALIZED)---EXIT ROUTE 1:20 30 50 INSIDE CURB CAN CATCH 1:15 30 37.5 /� TREADS ON EXTERIOR STAIRS. WHEEL AND CREATES - -- T-1_ HORIZONTAL NOSINGS SHALL PROJECT NO HT. AND SPACING PER 2'-4' ABOVE .-.`r� -(RAISED GRADE 2 BRAILLE �� TRIPPING HAZARD MORE THAN 1 1/2 INCHES. WATER SHALL CSC 118-703• HERE) ,� I \ RAMP SURFACE X i ,X NOT ACCUMULATE ON THE TREAD CONTRASTING BORDER COMPONENTS OFA SINGLE RAMP SAMPLE RAMP I 11 NOTE: 36 MIN. GROUP R, OCCUPANT LOAD // / DIMENSIONS 50, 60 TO PRIMARY ENTRY, OCCUPANCY RESISTANT.TREAD SURFACE TO BE SLIP TO LATCH LETTERING m Q MAX. HORIZ. ACCEPTABLE UNACCEPTABLE SECTION B 300, 48" MIN. ALL OTHERSQ AND BRAILLE � � � / HORIZONTAL PROJECTION OR RUN X t SLOPE MAX. RISE (IN.) PROJ. (FT.) 1'1 __\... I ly.:_!i 1:12 TO <1:16 30 30 fli..."1.1 / 1:16 TO <1:20 30 40 LEVEL LANDING FIG. 16 3I STAIRS, RAMPS, RAILINGS, SIGNAGE N.T.S. WA1U LOW: - SPOUT SHALL PROVIDE A FLOW "STRAIGHT-THROUGH" PLATFORM "HI-LO" DRINKING FOUIfjAIN OF WATER 4 INCHES HIGH MIN. LIFT PLAN "90 DEGREE TURNING" PLATFORM WHEELCHAIR UFT NOTES: PROTRUDING OBJECTS STREAM MEASURER HORIZ UFT PLAN [SECT. 11B-204] . ACCESSIBLE RELATIVE TO THE FRONT FACE USE UFT TO PROVIDE INTERIOR OR EXTERIOR ACCESS WHERE EXISTING , FOUNTAIN OF UNIT. SITE CONSTRAINTS OR OTHER CONSTRAINTS MAKE USE OF A RAMP ' STANDARD W!-IERE SPOUTS ARE LOCATED 90' TURNING STRIKE SIDE OR ELEVATORS UNFEASIBLE. `+ FOUNTAIN;� LESS THAN 3 INCHES FROM �� N. -� FRONT OF UNIT, ANGLE OF WATER STREAM SHALL BE 30 PLATFORM LIFTS CLEARANCE: II UFT MUST BE SELF OPERABLE WITHOUT ASSISTANCE, KEYS OR OTHER 1////////////////. i o DEC. MAX, BETrYEEN 3 AND 5 N INCHES, 15 DEC MAX. " " 18" 0 INTERIOR, \ -•� SECURITY DEVICES. � IMAX' ANY AMOUNT !r U[l 42 MIN. + DR. WIDTH OR 60 MIN.; " \ ,C a:r,•••-,r. - „/ CLEAR WIDTH CLEAR - 8 WHICHEVER IS GREATER 24 0 EXTERIOR . :-:•:~e:-:-:e•: s� " FLOOR 85 t. SCREW DRIVE •,,r W CONTROLS: CONSTANT PRESSURE TYPE: PUSH-BAR OR EQUALLY / /� X 12 MAX. `�`-� • /� POWER UNIT NON-SUP �,�"' Z -/ N SPACE . .• 4., Q ACCESSIBLE CONTROL / TYR PROTECT SHADED AREA . -� DEPTH OF ALCOVE TO BE CONTROL BOX PLATFORM ,�`• * a 6 % FROM CROSS-TRAFFIC I: - AT LEAST AS DEEP AS TOP LANDING TOP AND BOTTOM LANDINGS MUST HAVE A SOLID DOOR OR GATE 42" r NOTE: 3�• 41:j- DRINKING FOUNTAIN UNIT. z / CANE DETECTION AREA x RECOMMENDED �� Nr- - - - - 1 r . - 4'-O" DOORLa' - - ' IN HEIGHT, LEVEL CLEAR SPACES OF 60" SQUARE MINIMUM. UFT z / f i Q ISOMETRIC ��• ` 3'_0, �� MUST BE OPERABLE ONLY WHEN DOORS OR GATES ARE PROPERLY m BARRIER INCLUDES ' V N. CANE DETECTION 18 18 �� `�' Q DOOR CLOSED. SEE "DOOR APPROACHES" IN "1. PATH OF TRAVEL" FOR j THIS IS N o " " �1°� _ `'� ¢ z / r3 RAIL WITHIN 6 OF y y y N , , x •, '• . o c� STRIKE SIDE CLEARANCES AT DOORS. 'c) - A SIGN ` t \ FLOOR 'I 'I 'I NOTE: WALL " " o .( -/ce N / .. ¢ V I \ \- IF ALCOVE DEPTH IS z\ to 18 MIN• NON-SUP CALL-SEND CONTROLS MUST BE AT EACH LANDING AND COMPLY m cc / `' /� m OVERHEAD HAZARDS GREATER THAN 24% , INTERIOR, 24" - PLATFORM WITH SECTION 3105(F) OF TITLE 24. o j �x I iLI l`- \ \ Ni1 rj Ili-1 THEN ALCOVE WIDTH • J D -e MIN. EXTERIOR\ �� � ._ �� , MUST BE 36 MIN. • NOTES: IF A RAMP LANDING IS PROVIDED, r //i///i///./< CLEAR ��,;(3.9f t'L.A REMLING 60' MIN. THE FOLLOWING CLEAR INSIDE CAB DIMENSION COMBINATIONS 1:12 SLOPE MAXIMUM FOR RAMPS 15" LONG OR GREATER. FLOOR a V CLEAR AND LEVEL ARE ACCEPTABLE AS ILLUSTRATED: " IF BOTTOM OF OBJECT IS IF BOTTOM OF OBJECT IS IF OBJECTS ARE MOUNTED \ 6526 UPPER PLATFORM .-0 MIN. CLEAR e W D J 2:12 SLOPE MAXIMUM FOR RAMPS LESS THAN 15 LONG. ABOVE 27" BELOW 27" ON POSTS OR PYLONS �j2" MICV� DACE SPOUT to *- i WIDTH DEPTH JAMB (PLAN 't ENLARGED PLAN SAN F HANCISCO 60140" MIN. CLEAR AND PROVIDE STANDBY POWER OR SELF-RECHARGEABLE BATTERY POWER WALKING PARALLEL TO A WALL clop, LEVEL LOWER PLATFORM A. 3'-6" MIN. 5'-0' MIN. 4" MAX. TO ENSURE CONTINUED OPERATION FOR 5 UP AND DOWN TRIPS IN / / B. 4'-O" MIN. 6'-O' MIN. 4" MAX. THE EVENT OF A PRIMARY POWER LOSS. �(�: THERE ARE ADDITIONAL RESTRICTIONS ON THE USE OF LIFTS IN NEW CONSTRUCTION. REFER TO ADAAG 4.1.3. EXCEPTION 4. This drawing is the property of Associated Space Design, Inc. and is not to be 4 I WHEELCHAIR LIFT N.T.S. 5 I PROTRUDING OBJECTS N.T.S. 6 I DRINKING FOUNTAIN N.T.S. reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated MULTIPLE ACCOMMODATION RESTROOMS herein are for reference only as normal SINGLE ACCOMMODATION RESTROOMS GRAB BARS SECT. 11B-609.2 URINALS SECTION 11B-605 LAVATORIES ADA PERMANENT ROOM reproduction processes may alter the SECT. 11 B-6031 [ ] [ ] p y [SECT, 11B-603] 60" III. CLEAR (OUTS G) 1 1/2, - �� 18" 18"k IDENTIFICATION SIGNAGE accuracy of original drawings. " ' 48" MIN. CEA' 14' MIN, }, 48" MIRROR ---s-: LEVER VALVE X k LOCATED ON STRIKE SIDE 60" MIN. Associated Space Design, Inc. 2016 60 MIN f I ( " ) : ::: T.- ............. \� �� 17" MIN. CI) _C11-) \25' MAX. REACH FROM ADJACENT SIGN WITH FACE OF FINISH 36 BAR MIN. _ T- / " INSULATED TRAP AND HOT _ _ _FRONT OF COUNTER TO GRADE 2 BRAILLE (A) 60' MINIMUM x 30' MINIMUM / CENTERLINE OF HANDHELD ELONGATED RIM r- - - Y' , 25 MA -_ WATER. " SPRAYER MOUNTING BRACKET /� " " z o 1 1 4" TO 1 1 2' z . FRONT OF FAUCET " " ROLL IN SHOWER BACK/CONTROL MAX 7 MIL-18" MA 18 MIN :. a / �' / / WITH NO SIDE , / / NO EXPOSED SHARP OR CONTROL SEE RESTROOM 18 MIN. CLR /CONTROL a / z DIAMETER Q r� OBSTRUCTIONS �, _ - ,� ABRASIVE SURFACES IN " IDENTIFICATION" 9" MIN. �/ NOTEs: 1:48 MAX SLOPE IN ANY - ' k 22-23' -, ` , I ��. �. x ' KNEE SPACE, TYP. 8 KNEE CLEARANCE (BELOW} // Li ItKS AND NUMBERS ON SIGNS SHALL DIRECTION. 1' MAX GRATE y `` 4k-4�� ¢ r - I 1' i ¢ AR VARIES BE RAISED: CONTRASTING IN COLOR. OPENING. I i z za `�Qm 4 l3 1/ `Trp, - m m , /. LO RAISED CHARACTERS ON SIGNS SHALL BE m z Q� `L ? 32" MIN. ;� MIN. l�ru�' \i " FLOOR 29" MIN. VERTICAL CLEAR FROM FINISH SELECTED fROM FONTS WHERE THE WIDTH wo o 0�, CLEAR ,( \�1 01 M SPACE OF THE UPPERCASE LETTER 0 IS 60 us�' FLOOR CLEAR 'jr � y o� "' "' , FLOOR TO UNDER COUNTER WHEELCHAIR PERCENT MINIMUM AND 110 PERCENT "' r� " �0��� SPACE TOILET & ACCESSORIES CLEAR FLOOR \. ... c �1r 3O L CLEAR FLOOR SPACE TYPICAL u z 60 MIN. _ •••r SPACE �I ( } MAXIMUM OF THE HEIGHT OF THE �� • • 8" MIN. 6" MAX. IDIUPPERCASE LETTER "I". STROKE ` �). 7� f ik \ THICKNESS OF THE UPPERCASE LETTER 'I' a �1/2" MAX ¢ . --" P� cy NOTE: NOTE: a z HEIGHT OF THE CHARACTER. CLEAR FLOORIn �' SHALL BE 15 PERCENT MAXIMUM OF THE m THRESHOLD �, v z z ALSO SEE ADA FIG. 29 (b) FOR SIDE ‘`-'21P ,, J M �0 SPACE ��\a "-a- c,, DOORS MUST GRAB BAR AND OVERALL STALL FLAT FACE COAT HOOK ON WALL ACCESSORIES Z Q P WHERE PERMANENT SIGNAGE IS PROVIDED - • " :� COMPLY WITH DIMENSION REQUIREMENTS FOR VARIOUS OR PARTITION OTHER THAN DOOR m m J FOR ROOMS AND SPACES, SIGNAGE IS " FLUSH\ t. \ SECTION 3304 TYPES OF ACCESSIBLE RESTROOMS. PREFERRED , 'I �� `� TITLE 24 co c~ii ¢ 1- PROVIDED FOR ROOMS AND SPACES; 60 MIN. w SIGNAGE AS DESCRIBED ABOVE SHALL C $:•:•:•:-:•:•:•:•:-.•:-...„0:-:•:•:•:•:•:0 VALVE DOORS (SEE SEAT COVER DISPENSER SIDE WALL �p •\Q P�.k ALSO BE PROVIDED ON THE STRIKE SIDE 32" MIN. LOCATION PREFERRED = OF 000R• " ON •WIDE P.3) GRAB BAR ® 250 `� �`' 5 5 7 MAX),MAXPRIVACY LOCK _ _ POUND CAPACITY QP `� ��� QP O� SQ�Q C0 \ n CLEAR / SIDE -' l ON DOOR : " 54" MIN. , P P ` 7' MAX w 0 07.01.19 ISSUED FOR PERMIT -\-i •' MIN l'-O" 42" MIN. 'I, (B) ELEVATION-60' MINIMUM X 19" MINI a NO: DATE: REMARKS ....:::•..............•a: . ..................:.>is�:K.::-a::: :•::::•:•:•:•:•.• SANITARY NAPKIN " e: 30 MINIMUM ROLL-IN SHOWER 1•'' M N-18' MAX I I I DISPOSAL 7 IN-9" MAX 1 I I - RESTROOM IDENTIFICATION SIGNAGE (AT DOOR) RESTROOM IDENTIFICATION SIGNAGE " / le CONTROL AREA O REVISIONS: 30" MIN. SEAT SHALL FOLD TO YIITHIN 6 • N /,3• BAR. MIN. �e I' ` s �'- 12"MI I -' \ (ADJACENT TO DOOR) 59 HOSE MIN. f \ \ OF SIDE WALL SURFACE .-, � o Y � DRAWING TITLE: 17 MIN-18 IMAX Q NOTE: i " �' -i- \� ENTRY DOOR, PP. o t- m o " " Q x DOOR E of ANY TOILET > ` e x $ C DISABLED ACC ESS 2 WHERE SIX OR MORE STALLS (WC + URINALS) ARE PROVIDED O "�I' o c,r o ,� '�,' '� I � 0 o lam' • " Q z O O FOLDING SEAT -, M 47 a z Q STANDARDS (REFERENCE WITHIN A MULTIPLE ACCOMMODATION TOILET ROOM, AT LEAST r " ,M•, o �¢ �„ ` `� z • ONLY} Q Y& ONE STALL SHALL BE PROVIDED FOR THE SEMI-AMBULANT ASMCD ` �_ 24 MIN. / �- x �` ,�, cn oo ,., ao a PER 3100A b 3A (iv). TITLE 24. -`� m TEN ::I `�- ~' IL ROLL 'APER HOLDER w I / PROJECT NO.: ISSUE DATE: DOORS OTHER THAN DOOR ACCESSIBLE STALL(S) MAY 1/4' 11 • N WOMEN MEN TACK CONTROL AREA \ \ \ `� 28021.00 07.01.19 WITHOUT STOPS o 1/4' THICK /4' THICK THIN( 1/4 THICK DRAWN BY: CHECKED BY: -t- ENCROACH ENCROACH ON 60' CLEAR TURNING AREA NO MORE THAN 12'. o WOMEN UNISEX TRIANGLE MEN (RAISED 2 (RAISED GRADE 2 N- - - 17"-19' TO TOP - OF TOILET SEAT f l + 1� � Rota�1 AR AT a) SHEET NUMBER p C\E 7 I TOILETS AND FACILITIES N.T.S. 8 I ACCESSIBLE SHOWER STALL N.T.S. DA-REF c., 1 1