Loading...
Specifications OFFICE COPY OFFICE COPY 1\46-c,2bZ.1- 00011 NEC-2021- 000 12 MEG207,1 -00015 CSTFW y URAL CALCULATIONS CULLUMBER ENGINEERING OOWW For Tigard Business Park: Tenant RECEIVED JAN 6 2D21 Imp rove m e nt %ITY OF TIGARD BUILDING DIVISION Client: PM Design Group Project Address: SW Garden Place, Tigard, OR 97223 Homeowner: - Project Number: CM110920 Purpose: Structural Engineering for T.I. Date: 111/11/2020 Engineer: D. Goretoy, E.I. EOR: Wesley Cullumber, P.E. The design calculations contained herein have been prepared by or under the direction of the following Registered Civil Engineer: WE5LEY CULLUMBER N 80675 / r * r„, 03- t-2t sakiit Wesley Cullumber, PE CullumberEng.com wcullumber@CullumberEng.com 916-251-9798 STRUCTURAL CALCULATIONS 4.0").471."..keN Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DESIGN Ito ProjectNo.: CM110920 Table of Contents 1. DESIGN CRITERIA 2 PROJECT APPROACH 2 DESIGN VALUES 2 CODE REFERENCES 3 2. SEISMIC ANALYSIS 4 3. WIND ANALYSIS 5 4. STRUCTURAL CALCULATIONS 6 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 1 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 ND DESIGN INC ProjectNo.: CM110920 1. DESIGN CRITERIA PROJECT APPROACH Typical design approach for gravity and lateral analysis. Seismic loading applied for lateral analysis. Gravity loading applied as specified in the calculations. DESIGN VALUES 1. CRITERIA Risk Category =II 2. GRAVITY LOADS Space heater Weight (DL) =90 lb 3. SEISMIC LOADS MCER ground motion(period=0.2s) Ss =0.863g MCER ground motion(period=1.0s) S1 =0.395g Design Spectral Acc.for Short Periods SDS =0.691g Design Spectral Acc.for 1-sec. Periods SD1 =0.525g Response Modification Factor R =2.5 Soil Site Class =D Seismic Design Category = D Basic Seismic Force Resisting System: design for non-structural components 4. WIND LOADS(not in scope) Ultimate Wind Speed(3-Second Gust) =96 mph Basic Wind Speed,Vasd =77 mph Wind Exposure =C Topographic Factor Kzt = 1.0 5. GEOTECHNICAL(not in scope) ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 2 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 A r,,r^. hrc1 ,--f ProjectNo.: CM110920 CODE REFERENCES ASCE 7-16 Minimum Design Loads for Buildings and Other Structures ACI 318-14 Building Code Requirements for Structural Concrete and Commentary CBC 2019 California Building Code 2019 AISC Steel Construction Manual 14th Edition ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 3 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 r,l .-: Project No.: CM110920 2. SEISMIC ANALYSIS OTC Hazards by Location Search Information . v Address: 11952 SW Garden PI,Tigard,OR 97223,USA V.-mr-rwver 193ft Coordinates: 45A33863,-122.7630817 t*rir'i land Hdlsbom o qk Gresham Elevation: 193 R Beaver on �'- Ml. Tirnestamp: 2020-11-10T23.29:34A28Z Nation Hazard Type: Seismic Reference ASCE7-16 Go gle © Map ieia 2070 Goggle Document: Risk Category: � Site Class: ©-de+atilt Basic Parameters Name Value Description Ss 0,863 MCER ground motion(period=0,2s) St 0,395 MCER ground motion(period=1,0s) SMS 1.036 Site-modified spectral acceleration value Skit * Site-modified spectral acceleration value SOS 0.691 Numeric seismic design value al 0.2s SA Sol 'null Numeric seismic design value al 1.0s SA "See Section 11.4.8 •Additional Information Name Value Description SDC -:Tull Seismic design category F. 1.2 Site amplification factor at 0.2s Fv 'null Site amplification factor at 1.0s CRS 0.887 Coefficient of risk(0.2s) CR1 0.867 Coefficient of risk(1,0s) PGA 0.393 MCEO peak ground acceleration FPGA 1207 Site amplification factor at PGA PGAM 0.474 Site modified peak ground acceleration ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 4 of 13 STRUCTURAL CALCULATIONS Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 ANC. Project No.: CM110920 3. WIND ANALYSIS OTCHazards by Location Search Information v Address: 11952 SW Garden PI,Tigard,OR 97223.USA Vanrviuver b-3 193 ft Coordinates: 45A33e63.-122.7630817 c"I" land idlsimroo O Elevation: 193ft Heave on Gresham Mt. Timestamp: 2020-11-10T23:29:02.855Z Nation Hazard Type: Wind (� Go,' g:. le Map data iP.'p{;nnilR ASCE 7-18 ASCE 7-10 ASCE 7-05 MRI 10-Year 86 mph MRI 10-Year 72 mph ASCE 7-05 Wind Speed 85 mph MRI 25-Year 72 mph MRI 25-Year 79 mph MRI 50-Year 77 mph MRI 50-Year 85 mph MRI 100-Year 82 mph MRI 100-Year 91 mph Risk Category I 90 mph Risk Category I 100 mph Risk Category II 96 mph Risk Category' 110 mph Risk Category III 103 mph Risk Category 11-tV 115 mph Risk Category IV 107 mph The results indicated here DO NOT reflect any state or loud amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are Interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer.Per ASCE 7,islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area-in some cases,this website wil extrapolate past the last wind speed contour and therefore,provide a wind speed that is sightly higher.NOTE.For queries near wind-borne debris region boundaries,the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. Mountainous terrain,gorges,ocean promontories.and special wind regions shall be examined for unusual wind conditions. Whie the information presented on this website is believed to be correct,ATC and its sponsors and contributors assume no responsibility or liablity for its accuracy.The material presented in the report should not be used or relied upon for any specific application without competent examination and verification or its accuracy,suitability and applicability by engineers or other licensed professionals.ATC does not intend that the use of this information replace the sound judgment of such competent professionals,having experience and knowledge in the field of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website.Users of the information from this website assume all liability arising from such use.Use of the output of e,ie um/helix/line nest imply ennrnvai in,the nnvnrn inn hni6fenn end,,hndiae raennneihla tem h,delinn endo annrn,n,l anti intarnratafinn far the. ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 5 of 13 STRUCTURAL CALCULATIONS • ilThes, Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW SW Garden Place,Tigard,OR 97223 " I DESIGN INC Project No.: CM110920 4. STRUCTURAL CALCULATIONS 1 E L 1_,. :---4 Y ----___ -. .- 1 1 i SPACE HEATER LOCATION 1 I I • 1 al. -1 l I_, - I ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 6 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR97223 ND �ESk I'd IiVa. Project No.: CM110920 V♦•a".�'"_a'-3�Tc'�r'e#-77,7 r_.s L.rd,iv{17 fr.1-_. Description: 'Seismic Demand on Non-Structural Components 'Date: I11/11/2020 (ASCE 7-10&16, 13.3) Lateral Force Procedure Occupancy Importance IP 1.0 Design Spectral Accele Sps= 0.691 g Design Spectral Accele SDI= 0.525 g ComponentAmplifical ap Component Response Rp Fp= [0.4apSDSWp*(1+2z/h)]/(Rollo) Component Weight apHorizontal Shear Vertical Shear Remarks p lb R p Fp Max Min, Design Fp Fv Design Fv Space Heater 90 1 2.5 0.33 1.11 0.21 30 0.14 12 Heater with Bracket system by manuf. Equations: Horizontal Shear Design Fp= (1.2apSDsWp)/(Rollo) Fp is not required to be taken greater than Fo= 1.6SDSIpWp Fp shall not be taken less than, Fp= 0.3SoslpWp Vertical Shear Fv= 0.2SDSWp ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 7 of 13 STRUCTURAL CALCULATIONS 00.0.,49,04171"keks. Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DE.5lut Project No.: CM110920 j. r % d=6" /,/ min . ' T aggi ILC do=12" A34 min .' min ,/,/ 117 DL=90# Fv=12# WOOD BLOCKING ATTACHMENTS Load Combo LC=DL+0.7Fv=99# At wood blocking Assume dc=18"stead 1/2"dia thru bolt w/2"dia.washers If 4x12 DF#2. Fc_perp=625psi Mc=O-T(d) -LC(dc) Washer area A=nrA2=3.14 inA2 Allowed Ta=Fc'A=1,960#>T OK! T=LC(dc)/d=99'18"/6"-297# Vertical Shear Z=510#>LC OK! T=C Wood blocking to studs If Simpson A34 at top&bot Z=395# Z>T&C OK! At Concrete Wall If 1/2"dia. Hilti KWIK Bolt 3 carbon Steel Embedment length Le=2.25"min. Z=1,865">LC OK! Ta=1,235#>T OK! ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 i WEB:www.CullumberEng.com Page 8 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 .ND DESK' Project No.: CM110920 Mr'nunic.]I unc wwn0 Systems KWIK Bolt 3 Expansion Anchor 3.3.6 Table 6-Carbon Steel KWIK Bolt 3 Allowable Loads in Normal-Weight Concrete' Anchor Embedment1'.-2000 pal(13.6 MPa) I -3000 pa(20 7 MPa) I -4000 psi(27 6 MPa) 1'..`6000 psi(41.4 MPa) Demeter Depth Tension Shear Tension Shear Tenson Shoat Tenon Show in. (men) in. (mn) b (kt*) b (kN) lb(kN) lb (kN) lb (kN) lb (kN) b(kN) lb(kN) 1-178 R9Y 300 365 430 550 (1.31 11.6) 11.9) (2.4) 1/4 2 (51) 635 530 715 530 800 530 530 (6.4) (2.81 (2.4) (3.2) (2.4) 13.6) 57.4) 845 (2.4) 3 (76) 755 795 840 (38) (3.4) 13.5) (3.7) 730 1135 910 1275 1095 1090 1.5;9 1411 (32) (5.0) 14.0) (5.7) (4.9) (4.8) 3/8 1260 1555 1850 1315 2060 1315 (95) 2.1/2 (64) (5.61 1315 16.9) 1315 (8.2) (5.8) (921 (5.8) 1580 (5.8) 1770 15.8) 1965 2150 3.1/2 (89) (7.0) (7.9) (8.7) (9.6( 1235 1865 1430 2300 1820 2405 1975 2.1/4 (571 (5.5) (8.3) 16.4) (10.2) (7.2) (10.7) (8.81 1/2 3.1/2 1930 2165 2440 3240 2415 (12.7) (8A 2415 (9.7) 2415 (10.9) 2415 (14.4) (10.7) 4-3/4 (121) 2135 (10.7) 2355 (10.7) 2575 (10.71 3620 (9.51 (10.5) (11.5) (16.1) 1920 2750 2065 3410 2210 3755 2130 2-3/4 (701 (8.5) (12.2) (92) (15 2) (9.81 (16.8) 02.61 5/8 4 (1021 2660 3020 3385 4770 3910 089) 01.8) 3910 (13.4) 3910 (15.1) 3910 121.2) (17.4) 5.1/2 1140) 3285 (17.4) 3695 (174) 4100 117.4) 5325 (14.6) (16.4) (18.2) (23.7) 2120 4090 2425 4900 2730 5310 3785 5310 3 a;4 (831 (9.4) (18.2) (10.8) (21.8) (12.1) (23.6) (168) (23.6) 3/4 4.3/4 (121) 3240 4260 5285 6155 (19.1) (14.4) 5340 (18A) 5340 (23.5) 5495 (27.4) 8225 4535 (23.8) 5860 (23,8) 7185 (244) 7005 (27.7) 6-1/2 (165) (20.2) (26.1) (32) (31.2) 4•1/2 (1/a) 3330 7070 4050 7600 4870 8140 5070 (14.8) (31.4) (18.0) (33.8) (20.8) (36.2) (22.6) / 6 (152) 4930 6000 7070 8400 9200 (25 41 121.9) 9200 (26.7) 9200 (31 4) 9200 (37.4) (40 9) 9 12291 6670 140.9) 7670 (40.9) 8670 (40.9) 10670 (29.71 (34.1) (38.6) 07.5) I M11ninedcile toed vales Ib other concrete teerplhe.M reebobsi lents WI be L4kw(nlcd by blear MNNPWBrbn <a Inc RA11.4OPlabbo e I. .tn.hen cem 1.n aal+✓"'I I.»'O.4Ta.sepo I not(Canada;Ccii I800.1634iSe I Wwla.laeca 14ntlW Tantcarq lowed Guide 2011 299 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 9 of 13 �� STRUCTURAL CALCULATIONS Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DESIGN IN Project No.: CM110920 Table 12B BOLTS: Reference Lateral Design Values,Z,for Single Shear (two member)Connections'-' fnr sawn lumber nr SG_main member with 1/4'ASTM A 36 steel side plate Trscxness i e 0 Egg s '� LL LL LL Z ` ` v � V to csm 7 4 g, o o 3e _ $ z o gpg a & II8m o 3 g a p C 7 U C . 0 . 2.. �2 R. t. 0 4 Zj Z. Zi 4 Zi Zs Zi 4 Z5 Zn Z. 4 Z. Zs Z,r Zs 4 4 4 In. in. in. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. Rm. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. 112 730 420 620 350 580 310 580 310 550 290 520 280 510 270 470 240 460 240 450 230 618 910 480 780 400 730 360 720 360 690 340 650 320 640 320 590 290 580 280 560 270 1-172 114 31'4 1090 550 940 450 670 420 860 410 B20 390 780 360 770 360 710 320 690 320 6-80 310 718 1270 600 1090 510 1020 470 1010 450 960 430 910 410 900 400 820 370 810 360 790 350 1 1460 660 1250 550 1170 510 1150 500 1100 480 1040 450 1030 450 940 400 930 400 900 390 1,2 610 460 690 370 640 340 630 330 600 310 570 290 560 280 510 250 500 250 490 240 5/8 1020 520 870 430 800 390 790 380 750 360 710 340 700 330 640 300 630 290 610 280 1-3,4 1/4 314 1220 590 1040 480 960 440 950 430 900 410 860 390 840 370 770 330 750 330 73D 320 7/8 1420 650 1210 540 1130 490 1110 480 1050 450 1000 420 980 420 890 380 880 370 850 360 1 1630 710 1380 580 1290 540 1270 520 1200 500 1140 470 1120 460 1020 410 1000 410 980 400 1/2 930 600 860 470 830 410 820 400 780 380 740 350. 720 340 650 300 640 290 62U 260 5/8 1370 670 1150 530 1050 470 1040 470 980 430 920 400 910 390 810 340 800 330 770 320 2 1.2 1t4 3/4 1640 750 1370 590 1270 530 1250 520 1180 490 1110 450 1090 440 980 380 960 370 930 360 7/8 1910 920 1600 650 1480 590 1450 570 1370 530 1290 490 1270 480 1140 420 1120 410 1080 400 1 2190 880 1830 70D 1690 640 1660 620 1570 580 1480 540 1450 530 130D 480 1280 450 1240 440 112 930 620 860 550 1330 510 820 510 800 480 770 450 770 430 720 370 720 360 71D 350 i 5+8 1370 860 1260 690 1210 610 1200 600 1160 550 1130 500 1120 490 1060 420 1050 410 102D 400 3-112 114 314 1900 990 1740 760 1670 680 1660 660 1580 610 1480 560 1450 540 129D 460 1260 450 1220 440 7t8 2530 1070 2170 840 1990 740 1950 710 1840 660 1720 610 1690 590 1510 510 1480 500 1430 470 1 2980 1150 2460 890 2270 800 2230 770 2100 730 1970 660 1930 650 1720 560 1690 540 1630 530 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 10 of 13 STRUCTURAL CALCULATIONS 0•00,9004—h.hkes...4, Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DESIGN INC ProjectNo.: CM110920 G CEILING OR ROOF 7. I MIN. FRAMING LINE MIN. - SPACE HEATER BRACKET . SUPPOR PER MANUf, REQUIREMENTPie:1111 WALL MOUNTED /''� BRACKET MOUNTING IJT BRACKET / \ BY MANUF. ATTACHMENT PER DETAILS BELOW +- EXISTING(E)WALL SPACE HEATER BY OTHERS T- G K"I'1 MIN. SIDE VIEW FRONT VIEW ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 11 of 13 STRUCTURAL CALCULATIONS • • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DESIGN It,= Project No.: CM110920 f2)METAL STUD BRACE 3625162.43 TO R1 WALL TOP TRACE W)(3)t 10 TEK5 45°MAK. ! i PROVIDE DIAG.BRACE if(E)PARTITION 5 NOT SECURED AT TOP iI NEW BLKG INSTALL NEW BRACKET BACK PLATE TO SOLO If)MfTAt STUD If)METAL STUD BLKG SURFACE.REMOVE WALL WALL GYPSUM BOARD AS -1 NEEDED IY2 i..I (2)yio THRU BOLTS ter' MINIMUM Trial-BOLTMIN. I D_.. SPACING PROVIDE SOLID PLY BLKG A5 NEEDED (g)R 12 W000 OR�r. m . II ® TEK SCREWS TO BLKG ENDS t j,1 NEW 4%12 DF/2 HEATER SUPPORT INN i . • BLKG SEWN(f) HEATER SuPPORT BRACKET BY MANUf, li f l WALL STUDS BRACKET I SIMPSON A34 AT MB SECTION AA WI TEK SCREWS TO METAL STUD ATTACHMENT TO METAL STUD WALL 2 f2)METAL STUD BRACE 3625162 43 TO(E)WALL. TOP TRACK WI(3)M 10 TEAS 45'MAN. II . <` PROVIDE UTAG BRACE If(E)PARTITION IS NOT SECURED AT TOP NEW BLKG INSTALL NEW BRACKET - (E)WOOD 5t10 BACK PLATE TO SOLID i I (E)WOOD STUD- WALL 5tYsG SURFACE.REMOVE WALL J GYPSUM BOARD AS I NEEDED 1/2- (2)Y2'0 THRu BOLTS f-.__...3'J' _. MINIMUM TriRU-BOLT MIN -� II SPACING i !m (2)t 6D TO BLKG ENDS AT TOP.MID. IMF AND BOTTOM NEW 4%12 DM2 riEATER SUPPORT HEATER SUPr'OR7 1/2. -1111 BLKG BTWN CO BRACK):T BRACKET BY Maw,. MIN. WALL STLAS SIMPSON A34 AT TIB I ATTACHMENT TO WOOD STUD WALL I 3 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 12 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 DESIGN INC ProjectNo.: CM110920 lyz (E)CONC WALL MINIMUM THRU-BOLT MIN. SPACING (2) ,'0 CARBON STEEL MILTI KWIK BOLT 3 W/ iad3l EMBEDMENT HEATER SUPPORT lye BRACKET BY MANUF. MIN. ATTACHMENT TO CONCRETE WALL I 4 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 13 of 13 Centrifugal Ceiling Exhaust and Inline Cabinet Fans Models SP and CSP /IF 33 of r I r C m 1 ;1 GREENHECK 3 Building Value in Air. February 2019 Models SP and CSP tY @f° •: Ceiling and Cabinet Fans in. _Air `► — Great things come in small packages, as do our SP ceiling exhaust fan and CSP inline cabinet fan models. Be assured when you buy any Greenheck product, it is a quality product at a competitive price. Plus, we guarantee our SP and CSP fans with a three-year warranty. We are your market leader for the most comprehensive ceiling and cabinet fan line in the market. Typical Installations Benefits • Multifamily housing • Industry leading sound levels • Hotels • Compact size • Hospitals • Wide range of performance • Schools • Available with EC motors for higher efficiency and more controllability • Bathrooms • Helps maintain acceptable Indoor Air Quality • Storage rooms Table of Contents Standard Construction Features 4-5 Model SP-L 15 Power Ratings and Certifications 6 Model CSP-B 15 Certifications 6 Model CSP-A 16-17 Vari-Green® Motors and Controls 7 Model SP (50 cycle) 18 Sound and Fan Selection 8 Model CSP (50 cycle) 19 ENERGY STAR®and Codes and Standards . . . .9-15 Accessories 20-23 Model Number Code 9 Electrical Accessories 24-25 Model SP-VG 10 Discharge Accessories 26-27 Model SP-A-VG 11 Pressure Drop 27 Model SP-A 12-13 Specifications Vari-Green 28 Model SP-B and SP-C 14 Model Specifications 29-31 2 s Models SP and CSP � ,;, I�. Ceiling and Cabinet Fans Aauern Model Comparison Location Mounting Airflow Application Drive Impeller Type Performance U. O IT a Model 1 Q L. a a E i _ E e e o O a - -.. C 7 V o E o 0 E E i 0 o w m 'g _ g' m a d ._' c E in o .c . .. Z a d £^ Eve, 3 5 v °p R _ m a° w o S E o' rn 3 d I? d 'gE a — e 0 5 cc x 3 c� Evict a s 0 V w 0 v, •x •x m 0 0 a 2.8 f a SP ✓ ✓ ✓ ✓ ✓ V ✓ ✓ 1,600 1 CSP V ✓ ✓ ✓ ✓ I ✓ 3,800 1 SP fans are designed for ceiling mounted exhaust applications. CSP fans are designed for inline supply or exhaust applications. Model Level of Description Profile Sound Air Volume UL Listing Construction min.height min.sones max.cfm Premium Plus Fan: 7 inches 110 cfm UUcUL Listed for above bathtub/ SP VG Highest performing energy (178 mm) <0.3 (187 m3/hr) shower with GFCI branch protected efficient fan circuit(sizes 110 and 80 only) Premium Constant CFM 9 inches 130 cfm UUcUL Listed for above bathtub/ SP A-VG Ceiling Fan: (229 mm) <0.3 (220 m3/hr) shower with GFCI branch protected 3 speed cfm selection circuit Premium Ceiling Fan: UUcUL Listed for above bathtub/ Widest selection to meet sound 9 inches 1,600 cfm c SP A requirements. Select sizes (229 mm) <0.3 (2718 m3/hr) shower with GFCI branch protected u. available with Vari-Green motor. circuit(Sizes A390 and smaller) rn c Deluxe Ceiling Fan: 1 Compact to fit most 7 inches 200 cfm UUcUL Listed for above bathtub/ V SP B applications with quiet (178 mm) 0.8 (340 m3/hr) shower with GFCI branch protected operation circuit Low Profile Ceiling Fan: 35/e inches UUcUL Listed for above bathtub/ SP L Designed to fit in 2x4 wall (86 mm) 1.0 84 cfm shower with GFCI branch protected construction circuit. Economy Ceiling Fan: 35/s inches 50 cfm SP C Designed for light commercial (86 mm) 3.0 (85 m3/hr) UL Listed applications Premium Inline Fan: c CSP A Widest selection and industry- 9 inches 0.8 3,775 cfm ti leading low sound.Select sizes (229 mm) (6414 m3/hr) UUcUL Listed available with Vari-Green motor. Deluxe Inline Fan: 7 inches 185 cfm CSP B Compact design to fit in small ( ) 1.5 (314 m3/hi.) UL/cUL Listed remote spaces 178 mm All dimensions are in inches(millimeters) 3 Standard Construction Features rH ■t . \ . Va e in Air. gs u A� Model SP-A and SP-A-VG Model SP-B 3 ill-4g Villw 3 <; _1, 0, o 6 J, 11 • v�/ 12 . . . . . . 3 12 P It/ -0 < '' 14 9 0 4 0 • f g ' Model SP-L t . 11 3 46.. __,—___-,--...----.------ Model SP-C ''`1- 2 Model SP-VG 1 - 10 , 2 , 11 s 3 V •' 10 12r f 3 1 s -"........- --', 40: • 7 ,12 t 7 _ 11 1 •� 4 Model CSP-A Model CSP-B 94iiiik 0,, ©; 1 o 7 0 ©� sy, t " . >.. 12 A. 3 11 x 1 "' .. i 11 8 1 12—" O 10 ` 13 g 13 4 Standard Construction Features TEO( alue ran Mi.' ^w`;- Number and Description Specific Features for Each Model SP-VG SP-A SP-B SP-C SP-L CSP-A CSP-B Backdraft Durable plastic to reduce backdrafts 50-90 V V V V 1 Damper P Aluminum to reduce backdrafts V 110-1550 V 50-90 Round-For quick and easy connections V 50-90-VG V V V 90-130-VG 2 Outlet Square-For quick and easy connections 110-1550 V Oval-Metal construction for increased fire V resistance Removes quickly for maintenance/replacement V V V ✓ V V 3 Power Pack Includes conversion from horizontal to ✓ V vertical discharge Vertical electrical access to eliminate drilling holes V V Ceiling ✓ V 4 Electrical Access Horizontal electrical access Wall External electrical access to save installation time V V V 5 Electrical Eliminates drilling holes V V V V V V V Knockouts (horizontal or vertical) Acoustic V 6 Insulation Absorbs sound 7 Disconnect Servicing is quick and safe V V V V V V V 8 Electrical Large for easy wiring V V V V V V V Junction Box 9 Grille Concealed attachment screws securely fasten V V V grille to housing for quiet,rattle free operation 10 Mounting Adjustable for multiple installation conditions V V V V V ✓ Brackets Integral for quick installation I V Embossed galvanized steel for rigidity V V V V V V V 11 Housing A low profile for height restricted areas V V V V ✓ Motors are compatible for use with speed controls and have thermal overload protection 60 60 60 Domestic&International cycle, cycle, cycle, 12 Motors •50 cycle,220v or 240v 115v V ✓ 115v 115v ✓ V •60 cycle,115v,208v,220v,230v,&277v options only only only — (See CAPS or pg.6 for availability) Gain easy access to internal components once 13 Access Panel V ✓ V V V V V _ installed CFM Speed User-controlled internal switch to set fan to 50-90-VG 14 Selector operate at one of three speeds for desired airflow 90-130-VG Constant cfm motors capable of two speed 50 60 30 / 70 x \ Control with operation.Run at continuous low speed and 80(L) 403g70 75 45 50 90 s 45 Van-Green switch to high speed on demand.ASHRAE 62.2, 110(L) 30 80 s 60 30 110 5 60 Motor California Title 24 and Washington State Energy only CFM TIME ` CFM TIME Code compliant. sP-9gq.VG uwr.dluekSle controls SP-110(L)4G uger.divabbk•onbok Exclusive Electrical access cover located on the housing exterior.This feature permits external wiring without removing Electrical Wiring the power assembly,saving installation time and cost.Available on models SP-A and CSP-A. Feature Available for applications requiring 700 cfm or greater. Double-Wide Double-wide fans have two double-width forward-curved wheels, N i I r 1 Fans which are housed in separate scrolls,and driven by a single motor. Available on models SP-A and CSP-A. Vertical Exhaust outlet duct installed in the optional vertical position. Discharge The power assembly must be rotated to match the duct adapter position. Available on SP-A and CSP-A models. 5 I k Power Ratings and Certifications 1� , c ;- f{ -Va inAir. , Available Motor Voltage and Cycle Ratings Available Motor Voltage and Cycle Ratings Power Rating V/Hz Power Rating V/Hz Models 115V/ 115V/ 220-240V/ 220-240V/ Vari-Green Models 115V/ 115Vf 220-240V/ 220-240V/ Vail-Green Available(X) 60Hz 50Hz 50Hz 60Hz 277V Motor Available(X) 60Hz 50Hz 50Hz 60Hz 277V Motor Option Option SP-A50 x x x x x SP-050' x SP-A70 x x x x x SP-80 x x SP-A90 x x x x x SP-BOL x x SP-A110 x x x x x x SP-110 x x SP-A125 x x SP-110L x x SP-A130 x x x x x CSP-A110 x x x x SP-A190 x x x x CSP-A125 x x SP-A200 x CSP-A190 x x x x SP-A250 x CSP-A200 x SP-A290 x x x CSP-A250 x SP-A390 x x x x CSP-A290 x x x SP-A410 x CSP-A390 x x x x SP-A510 x x x x CSP-A410 x SP-A510-VG x x CSP-A510 x x x x SP-A700 x CSP-A700 x SP-A700-VG x x x x x x CSP-A700-VG x x x x x x SP-A710 x x CSP-A710 x x SP-A710-VG x x CSP-A780 x x x SP-A780 x x x CSP-A900 x SP-A900 x CSP-A1 050 x x x SP-Al 050 x x x CSP-A1050-VG x x x x x x SP-A1050-VG x x x x x x CSP-A1410 x SP-A1410 x CSP-A1550 x x x SP-A1550 x x x CSP-A1750 x SP-650 x CSP-A2150 x SP-B70 x CSP-A3600 x x x SP-680 x CSP-6110 x x x x SP-B90 x x x CSP-B150 x x x x SP-B110 x x x x CSP-e200 x x x x SP-B150 x x x x *Note:All motors are rated for continuous use except model SP-050. SP-B200 x x x x SP-L50 x SP-L80 x 'Note:All motors are rated for continuous use except model SP-050. Greenneck Fan Corporation certifies that the CSP models shown herein are licensed to bear Greenheck Fan Corporation certifies that the SP the AMCA seal.The ratings shown are based on rP tests and procedures performed in accordance models shown herein are licensed to bear the sin with AMCA Publication 211 and comply with AMCA seal.The ratings shown are based on tests "MM." the requirements of the AMCA Certified Ratings and procedures performed in accordance with Program.The COP models are not AMCA certified 'Pr O� AMCA Publication 211 and AMCA Publication 311 with 50 hertz motors. ,..22and comply with the requirements of the AMCA Certified Ratings Program.The SP models are not - AMCA certified with 50 hertz motors. ^Products that earn the ENERGY STARS ^ Cj (20 US LISTED prevent greenhouse gas emissions by meeting strict energy efficiency - guidelines set by the U.S.Environmental Models SP and CSP are listed electric fans(UUcUL 507). Protection Agency and the U.S. LEARN MORE AT Ceiling Exhaust Fans are also UL Listed for above bathtub/ Department of Energy. energystar.gov shower with GFCI branch protected circuit.File no.E33599. Note:SP/CSP fans are rated for direct contact with insulation. Fans that are ENERGY STAR certified include:SP-A70, SP-A90,SP-A110,SP-A125,SP-Al 90,SP-A200,SP-A250, SP-B70,SP-B80,SP-B90,SP-L50,SP-L80,SP-80-VG, SP-80L-VG,SP-110-VG,SP-110L-VG,SP-A50-90-VG, SP-A90-130-VG 6 Vari-Green® Motor & Controls . Value in,Pii` },. v VARI-GREEN Vari-Green® Controls by CREENHECK Air Quality-VOC- Control a Vari-Green motor via changes in Volatile Organic Compounds(VOC's).VOC's are gasses that are emitted from humans, building materials, perfumes,foods, and furniture off-gassing. aR { Range is 0-2000 CO2 ppm equivalent. , • Institutional facilities-Schools, court houses, hospitals; bathrooms,waiting rooms, cafeterias. ' r/ s • Commercial buildings-Offices, conference rooms, • `!� bathrooms, break rooms. - 00011 Air Quality-Temperature and Humidity-Control a Vari-Green motor via changes in temperature, humidity, or both. Range is 32°to 120°F and 0 to 100% relative Vari-Green® Motor humidity. EC Motor Technology Information &Advantages- • Multifamily structures-Apartments, condos, hotels; Greenheck's Vari-Green (VG) Electronically Commutated bathrooms, utility rooms. (EC) motor combines motor technology, controllability • Commercial buildings-Office buildings; offices, and energy-efficiency into one single low maintenance conference rooms, utility rooms, bathrooms. unit and is the industry's first fully controllable motor. Transformer- Provides 24V power from the existing The EC motor operates on AC power that is converted line voltage at the fan to the Vari-Green motor and to DC-providing more efficient motor operation as controls. Dual voltage primary (120/240V)transformer compared to an AC operation. The controllability of the provided with the fan. Vail-Green motor allows communication compatibility with a variable volume system. This allows speed Remote Dial or Touch Remote-Allows the user to adjustment of the motor to meet the needs of the manually adjust a fan's speed from a remote location system to exhaust air as needed and reduce over- and mounts to a wall using a 2x4 junction box.The exhausting conditioned air. 24VDC transformer, described above, is included with all orders.A wall cover plate is supplied. Available Vari-Green Controls and Models • The Touch Remote includes a countdown timer Models to automatically turn the fan off after 10, 30,60 or SP/CSP-A510-VG 90 minutes. Controls SP-80(L)-VG SP-A50-90-VG SP/CSP-A700-VG • Recommended for use in commercial buildings SP-110(L)-VG SP-A90-130-VG SP/CSP-A710-VG and restaurants. SP/CSP-Al050-VG VOC X Two-Speed Control with Integral Transformer- Temperature/ Control allows motor RPM to be set at two independent Humidity X speeds(high or low). Meets minimum airflow Two-Speed X requirements with the ability to bump up to high speed Remote Dial X or meet maximum airflow requirements or reset to low Touch Remote X speed for energy conservation. constant Pressure x Constant Pressure Control -Control Vari-Green motor Transformer x via static(variable volume)or velocity(constant CFM) pressure on the inlet or outlet side of the fan. Optional, Built-in Time Delay X - one or two,duct or room probes for use in: Built-in Two Speed X • Multifamily structures-Apartments, condos, hotels; Constant Airflow X X X dryers, residential kitchens and bathrooms. o-1ov DC X • Institutional facilities-Schools, prisons, CFM Speed Selector X multistory office buildings; bathrooms. See Greenheck's Vari-Green Motor and Vari-Green Controls brochures for more information. 7 Sound and Fan Selection "f -NH Things to know when sound is critical • va in Air. Sound Data take into account the desired sound level at the The sound data shown in this catalog has been location of the listener. presented to aid the system designer in selecting a The compact size of the SP and CSP fans provides fan which will meet the desired sound criteria. Sone the system designer greater flexibility in locating these levels have been included on the performance pages fans for lowest sound levels. In to provide a means of quickly evaluating the relative critical sound areas, insulated loudness of a fan selection. ductwork, flexible duct connections, or placing Fiberglass What is a sone? Remote Sones are an internationally recognized unit of the fan in a remote mounted section of the ductwork model CSP loudness. In practical terms, the loudness of one with vibration (away from the critical isolators and sone is equivalent to the sound of a quiet refrigerator insulated area) offers the best _____- ductwork measured from five feet away in an acoustically average means of meeting = " the provides g a, room. A sone is a single number rating, indicating the desired sound levels. installation. inlet noise derived from the eight audible octave bands. Sones are a linear measurement of sound level. For Why are low sound levels important? example, a sound level of 10 sones is twice as loud as The main application of a ceiling exhaust fan under 5 sones. 200 cfm is typically to exhaust odor and humid air from Can radiated noise increase sound levels? a bathroom. If a bathroom fan is excessively loud,the occupant will seldom use it. Lack of proper venti—lation Radiated noise from fan housings can cause may lead to a variety of concerns including damage unacceptable sound levels on any brand of fan. The to finishes, walls, ceilings and even health issues. size of these fans allows them to be placed in areas Greenheck is proud to offer some of the quietest fans where this noise will be transmitted to the conditioned on the market. space through walls or ceilings. Where possible, cabinet fans should be located in remote parts of the Why is Indoor Air Quality (IAQ) important? ventilation system. According to the United States Environmental Where should an SP or CSP fan be used? Protection Agency(EPA),the concentration of some Model SP and CSP are designed for the lowest pollutants are often 2 to 5 times higher indoors than possible S sound levels.fansF are designed wheels, outdoors.The average American spends approximately insulated housings and vibration isolators between important. 90% o tteP or moie sture onso IAQ is extremely to ly Poor moisture control may lead t mold the motor and housing contribute to quiet, efficient and mildew issues that may cause health concerns. operation. Applied and installed as recommended, SP Seemingly harmless items such as building materials, and CSP sound levels will fall well within the ranges shown in the Suggested Limits for Room Loudness personal care items and cleaning agents may contribute to poor IAQ.Greenheck ceiling exhaust fans are chart. For applications where sound levels are critical, guaranteed to effectively exhaust moisture and odors a remote mounted CSP with ductboard is from your bathroom. recommended. Placement of SP and CSP fans should Suggested Limits for Room Loudness Sones dBA When room sound levels are critical, such 1.3-4 32-48 Private homes(rural and suburban) i as in executive offices, conference rooms, 1.7-5 36-51 Conference rooms hospital operating rooms, and school study 2-6 38-54 Hotel rooms,libraries,movie theatres,executive offices areas, a CSP fan is the best choice. Shown 2.5-8 41-58 Schools and classrooms,hospital wards and operating rooms here is a comparison of SP and CSP fans Court rooms,museums,apartment houses,private homes of the same size, with equal performance in 3-9 44-60 (urban) typical installations. The CSP shows lower 4-2 48-64 Restaurants,lobbies,general open offices,banks Sone values. 5-15 51-67 Corridors and halls,cocktail lounges,washrooms and toilets 7-21 56-72 Hotel kitchens and laundries,supermarkets Model CFM WG FRPM Sones Reprinted from AMCA Publication 302(Application of Sone Ratings for Non-ducted SP-A410 405 1/8 1000 3.0 Air Moving Devices,with room-sone-dBA correlations)with the written permission from CSP-A410 403 1/8 1000 1.5 AMCA International,Inc.,30 West University Drive,Arlington Heights,IL 60004-1893. Sone value on CSP is with insulated inlet duct. NOTE:Values above are for room loudness and are not sound ratings.Room loudness is the resulting level in a conditioned space after the acoustical qualities of the room have been accounted for. 8 ENERGY STAR® •1 ram, Codes and Standards Value i • � ENERGY STAR® is a market-based partnership formed to reduce greenhouse gas emissions through energy efficiency and make it ^ Products that earn the ENERGY STAR easier for consumers to identifyenergy-efficientproducts that offer prevent greenhouse gas emissions 9Y PjK by meeting strict energy efficiency savings, performance,features, and comfort. guidelines set by the U.S.Environmental To earn the ENERGY STAR label, energy-products must meet strict LEARN MORE AT Protection Agency and the U.S. gY energystar.gov Department of Energy. efficient standards set by the U.S. Environmental Protection Agency (EPA)for energy consumption, air and sound performance. Fan Fans that are ENERGY STAR certified include: , SP-A90,SP-A110,SP-A125,SP-A190,SP-A200,0,SP-SP-A250, models that are ENERGY STAR certified are identified in this catalog. SP-B70,SP-B80,SP-B90,SP-L50,SP-L80,SP-80-VG, SP-80L-VG,SP-110-VG,SP-110L-VG.SP-A50-90-VG, Note: ENERGY STAR is only for products 500 cfm or less. SP-A90-130-VG Codes and Standards ASHRAE 62.2 sets the minimum Indoor Air Quality(IAQ)standards and minimum ventilation rates in commercial and residential buildings.This standard is used as the basis for state and local building codes such as the Washington State Energy Code. Select Greenheck fans are able to provide low speed continuous ventilation and cycle to high speed upon activation of a switch or a sensor. California Title 24 states that each bathroom shall be mechanically ventilated and shall comply with the following: Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. Humidity controls shall be capable of adjustment between a relative humidity range of less than or equal to 50 percent to a maximum of 80 percent. Multiple Greenheck ceiling exhaust fans can be used to comply with these latest codes and standards. Model Number Code The model number code system is designed to completely identify the fan. The remainder of the model code is determined by the size and performance of the fan. SP - A50L - VIG Model I L Vari-Green® SP-Silent Partner EC Motor Option CSP-Cabinet Silent Partner Light Options Level of Construction LED-Fan/Light(LED)Combination No letter designation Identifies model as Premium Plus with a Van-Green motor A- Premium unit;lowest sound,insulated housing Nominal cfm at 0.10 inches static pressure B- Deluxe unit; low sound,low profile L- Low Profile,ceiling/wall mounted C- Economy unit;inexpensive 9 Model SP-VG [JGREENfIECK Premium Ceiling Exhaust Fan VA,Pir.;.l. Model SP-VG Model SP-VG Dimensions SP-VG 80,110 J� Model A B C DE Designer Unit �g Grille Weight sound 1% 101/2 NERGYSTAR x •4 14 13 12 ) 1 ^ °m 80(L) (gas) (267) (1944) — (102) (356x330) (5) ■- 110(L) 11% 10'/ 7% 6 14 x 13 12 C �p"1 HVI CERTIFIED (289) (267) (194) (152) (ass x 330) (5) All dimensions are in inches(millimeters)and weight in pounds(kilograms).Outlet connection width is 1 in.(25 mm).Mounting bracket width is 11/2 in.(38 mm). —� C US LISTED For complete dimensional information,see CAPS submittal drawings. 410) 'Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model SP-VG Performance Model ENERGY HVI RPM Amps' Max. CFM/Static Pressure in Inches wg STAR® P WInaut tts" 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 SP-80(L)-VG ' + 935 0.1 6.1 CFM 80 80 80 80 78 66 38 Sones <0.3 <0.3 <0.3 0.6 1.4 2.2 3.0 SP-110(L)-VG ' + 940 0.2 8.4 CFM 110 110 110 109 100 62 28 Sones <0.3 <0.3 <0.3 1.4 2.3 3.0 3.6 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. 10 Model SP-A-VG Premium Constant CFM Ceiling Exhaust Fan Vie. e1uef, '' ' - Model SP-A-VG SP-A50-90-VG Model SP-A-VG DimensionsE or SP-A90-130-VG Model A B C D E Designer Decorative Unit Grille Grille Weight B -A_, LONE>ro SP-ASD-90-VG ( 13V 10% 9 6 14'%x 131/4 1514(387) 12 (337) (270) (229) (152) (378 x 337) square (5) O 1- SP-A90-130-VG D * All dimensions are in inches(millimeters)and weight in pounds(kilograms). _ \ - C US LISTED Outlet connection width is 1 in.(25 mm).Mounting bracket width is 11/2 in.(38 mm). For complete dimensional information,see GAPS submittal drawings. *Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model SP-A-VG Performance Model ENERGY CFM RPM Max Max CFM/Static Pressure in Inches wg STAR® Selection Amps* Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 CFM 50 50 50 50 50 50 50 50 50 50 808 0.29 22.1 Sones <0.3 <0.3 0.6 0.7 1.5 2.0 2.0 2.5 2.5 CFM/Watt* 56.5 20.7 17.3 9.9 6.5 5.4 4.0 3.4 2.9 Watts* 1.2 3.2 3.7 5.5 8.3 10.9 14.3 17.9 21.7 CFM 70 70 70 70 70 70 70 70 66 SP 70 838 030 23.3 Sones <0.3 <0.3 0.4 0.9 1.4 2.0 2.D 3.0 2.5 . A50-90-VG CFM/Watt* 56.2 19.7 17.4 10.4 7.2 5.4 4.2 3.5 3.0 Watts* 1.6 4.3 4.8 7.6 10.8 14.3 17.7 22.1 22.1 CFM 90 90 90 90 90 90 90 82 71 90 887 0.31 24.1 Sones <0.3 0.5 0.6 1.0 1.5 2.0 2.0 2.5 2.5 CFM/Watt" 28.7 18.1 15.4 10.4 7.0 5.4 4.5 3.6 3.2 Watts" 3.8 5.6 6.5 9.3 13.4 17.8 21.6 22.5 22.3 CFM 90 90 90 90 90 90 90 82 71 90 887 0.31 24.1 Sones <0.3 0.5 0.6 1.0 1.5 2.0 2.D 2.5 2.5 CFM/Watt" 28.7 18.1 15.4 10.4 7.0 5.4 4.5 3.6 3.2 Watts* 3.8 5.6 6.5 9.3 13.4 17.8 21.6 22.5 22.3 CFM 110 110 110 110 110 110 102.5 82 67 SP 110 960 0.31 24.2 Sones 0.4 0.9 0.8 1.3 1.5 2.5 2.5 2.5 2.5 A90-130-VG CFM/WatG 22.7 14.7 13.3 9.4 6.9 5.3 4.4 3.5 3.1 Watts" 5.6 8.4 9.1 12.7 17.0 22.1 23.4 23.4 22.2 CFM 130 130 130 130 130 122.7 99.1 80.8 63.7 130 1041 0.32 24.2 Sones 1.2 1.4 1.5 2.0 2.5 3.0 2.5 2.5 2.5 CFM/Watt" 16.2 12.0 11.1 8.5 6.2 5.1 4.2 3.4 3.0 Watts" 9.1 11.7 12.7 16.4 22.4 23.9 23.5 23.5 22.4 Performance certified is for model SP exhaust for installation type B.Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sores at 5 ft(1,5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. 11 Model SP-A =''H� �� Premium Ceiling Exhaust Fan 1IfG = a irA�-x31► ` -, Model SP-A Dimensions SPA 50-90 SP-A 110-510,510-VG, Designer Decorative Unit g; A 710-VG,710,780 Model A A B C D E ✓ �'� Grille Grille Weight l')1 1 13%4 10%e 9) -.-_8(152)6 !14/s x 13/4 15/4(387 (5)50, 2 If B 16)41 125 190 (337) (270) (229 ) 17 C D—,� I (337) (270J (229) (203) (152) (378x337J square (8) i 200,250,290, 14 11% 11'/4 8 6 24 �' r' �D� 390 (356) (302) (286) (203) (203) (11) Y 410,510, 18 14% 14Yz 8 8 193/B x 16'/B 31 ��' 710-VG (457) (365) (368) (203) (203) (492 x 416) (14) SP-A 700,700-VG, 700,700-VG 23/ 11 B/s 11'/a 19'Fz 8 25Ys x 13'/e 34 1050-VG,900-1$50 moo) (295) (295) (495') (203) (638 x 343) (15) 710,780 ik- 18 14/e 14(457) (365) 'z 10 8 19%x 16'/8 34 B 23/4 14/e l 4/z (254)) (203) (492 x 416) (15) �A rrs 1050900,1VG, 17/,e 8 25 x 16'/e 56 �\ I r- .< touno 1410,1550 ` (694 (365) (358) (443) (2 (25)050, aliti; „�« All dimensions are in inches millimeters and weight In pounds(kilograms) ®•• 03) (635x 476) C A FIVI Outlet connection width is 1 in.(25 mm).Mounting bracket width is t'h in.(38 nun). /, DQ CE RTIFlEo For complete dimensional information,see CAPS submittal drawings. C 0 US LISTED ^` r•e= � . r y' S ,,, t * ti ti M • N fi€ >.. '!`4 fig{ .� ¢ T - ' ' w„,,,,,,-.':.-', , i 5 lB.. 3 n£ , • x $=r .fie % K'. Ts f f to Model SP-A its .1 Premium Ceiling Exhaust Fan =fi Value •Continuous Ventilation Compatible: Low speed continuous operation is adjustable from 30 cfm to full rated fan speed *Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. ENERGY Continuous Control Max. CFM/Static Pressure in Inches wg Model e HVI Ventilation RPM Amps* Input STAR Compatible Voltage Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 1.25 SP-A50 + 790 0.33 25.9 CFM 89 66 61 31 Sones 0.4 0.6 0.6 0.9 CFM 88 74 71 54 SP-A70 790 0.14 15.6 Sones <0.3 <0.3 <0.3 <0.3 CFM/Watt* 5.64 4.97 4.83 4.12 Watts* 15.6 14.9 14.7 13.1 CFM 114 101 98 80 SP-A90 + • 870 0.14 16.9 Sones <0.3 <0.3 <0.3 0.4 CFM/Watt* 6.75 6.20 6.95 5.33 Watts* 16.9 16.3 14.1 15 CFM 130 119 115 98 SP-A110 ,`f ♦ 950 0.16 19.4 Sones <0.3 <0.3 <0.3 0.5 CFM/Watt* 6.70 6.33 6.15 5.54 Watts* 19.4 18.8 18.7 17.7 CFM 144 130 127 109 SP-A125 1010 0.19 23 Sates 0.4 0.4 0.4 0.6 CFM/Watt* 6.26 5.73 5.62 5.00 Watts* 23.0 22.7 22.6 21.8 CFM 229 214 210 186 156 SP-A190 1400 0.45 54.2 Sates 2,5 2.0 2.0 2.0 1.5 CFM/Watt* 4.23 4.08 4.05 3.78 3.36 Watts* 54.2 52.5 51.9 49.2 46.4 CFM 267 246 242 224 199 162 109 68 SP-A200 900 0.47 56.1 Sates 2.0 2.0 2.0 2.5 3.0 3.5 4.0 4.5 CFM/Watt* 4.76 4.42 4.34 4.10 3.75 3.19 2.29 1.49 Watts* 56.1 55.7 55.7 54.7 53.1 50.8 47.6 45.7 CFM 294 274 271 250 230 201 147 92 SP-A250 "t 1000 0.56 67 Sones 2.5 2.5 2.5 3.0 3.5 4.0 5.0 5.0 CFM/Watt* 4.39 4.18 4.12 3.89 3.67 3.36 2.65 1.80 Watts* 67.0 65.6 65.8 64.2 62.6 59.8 55.4 51.2 SP-A290 1050 0.72 80.7 CFM 315 293 287 257 231 207 175 124 Sates 2.5 2.5 2.5 3.0 3.0 3.5 3.5 4.5 SP-A390 1350 1.34 135 CFM 410 395 391 368 345 325 307 279 Sones 4.5 4.5 4.5 4.5 5.0 5.0 5.5 5.5 SP-A410 1000 1.74 121 CFM 443 413 405 351 306 Sates 3.5 3.0 3.0 3.0 3.5 SP-A510 1070 3.30 224 CFM 557 512 501 439 392 325 Sones 5.0 4.5 4.5 4.5 4.5 4.0 850 0.75 49.1 CFM 399 354 341 255 SP-A510-VG Sows 4.5 4.0 3.9 3.4 1275 2.40 155 CFM 604 583 576 540 495 443 377 Sones 7.9 7.7 7.7 7.3 7.0 6.8 6.4 SP-A700 1100 3.20 350 CFM 757 730 723 700 679 649 613 560 494 396 Sates 5.0 5.0 5.0 5.5 5.5 6.0 6.0 6.5 6.5 6.5 6 1275 1.82 111 CFM 568 527 517 466 419 372 329 275 223 170 100 SP-A700-VG Sones 3.5 3.5 3.5 3.5 4.0 4.5 5.0 6.0 7.0 7.0 9.0 10 1450 3.52 218 CFM 801 774 766 729 699 666 634 597 569 530 418 Sones 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.5 7.5 8.0 9.0 SP-A710 1080 4.40 285 CFM 752 714 701 653 588 486 320 Sones 6.0 6.0 6.0 6.0 6.0 5.5 5.5 925 0.96 60.4 CFM 441 410 397 327 SP-A710-VG Sones 4.5 4.3 4.2 4.0 1450 3.39 230 CFM 709 685 677 656 621 580 534 483 399 Sones 9.6 9.4 9.2 9.0 8.7 8.6 8.3 8.1 7.8 SP-A780 1600 3.30 348 OEM 812 782 775 741 704 665 625 581 Sones 8.5 8.5 8.5 8.0 8.0 8.0 8.0 8.0 CFM 955 907 896 841 773 701 SP-A900 950 4.00 285 Sones 4.0 5.0 5,0 5.0 5.0 5.0 SP-A1050 1095 6.30 420 CFM 1125 1059 1043 964 885 796 662 Sones 6.0 6.0 6.0 6.0 5.5 5.5 5.5 6 1050 1.94 120 CFM 838 789 779 735 685 632 579 SP-A1050-VG Sones 4.0 4.0 4.0 4.0 4.0 4.5 5.0 10 1225 3.75 240 CFM 1162 1106 1092 1023 944 831 668 Sones 7.5 7.0 7.0 7.0 6.5 6.0 5.0 SP-A1410 1450 7.40 786 CFM 1455 1415 1404 1353 1307 1262 1218 1174 Sones 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 SP-A1550 1610 8.60 818 CFM 1607 1558 1558 1506 1449 1407 1369 1323 Sones 10.5 10.0 10.0 10.0 10.0 10.5 11.5 13.0 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. 13 `-: Model SP-B and SP-C Deluxe and Standard Ceiling Exhaust Fan '` in Air4 Model SP-B Model SP-B Dimensions tee/'\ � , al Designer Decorative Unit A 1„ SOUAD Model A B C D E00,11111111117t EL,,aE_.;,,, Grille Grille WeightD C ntn ® MMOWOOr 50,70,80 13% 11/ 7 6 P/a 9 j ��' (352) (292) (179) (152) (32) 1478 x 13r/ 15%a(387) (4) �% NCER7��p 90,110,150, 13% 1 P/r 7 6 1 Ya (378 x 337) square 10 i��j���%i-y��% /- 200 (352) ( (292) ;179) (1152) (32) (kilograms).Mounting bracket width i*�j�i/��, All dimensions are in inches millimeters and weight inpounds `. ® US LISTED is Ws in.(38 min).For complete dimensional information.see CAPS submittal drawings. •Continuous Ventilation Compatible: Low speed continous operation is adjustable from 30 cfm to full rated fan speed *Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model SP-B Performance ENERGY Continuous Max. CFM/Static Pressure in Inches wg Model STAR® HVI Ventilation RPM Amps* Input Compatible Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 SP-B50 + ♦ 625 0.50 37.8 CFM 67 54 51 40 29 Sones 1.2 1.4 1.4 2.0 3.0 CFM 89 75 71 54 35 SP-B70 5-- + 675 0.16 17.1 Sones 0.8 0.8 0.9 1.4 2.0 CFM/Watt* 5.20 4.46 4.25 3.27 2.27 Watts* 17.10 16.80 16.70 16.50 15.41 CFM 94 81 77 62 46 Sones 0.8 0.9 0.9 1.3 2.0 SP-B80 A + ♦ 900 0.16 18.6 CFM/Wgtt* 5.05 4.40 4.21 3.44 2.71 Watts* 18.60 18.40 18.30 18.00 16.95 CFM 104 92 89 72 57 SP-B90 + 700 0.18 21.1 Sones 1.0 1.0 1.0 1.5 2.0 CFM,Wstt* 4.93 4.40 4.24 3.48 2.88 Watts* 21.10 20.90 21.00 20.70 19.77 SP-B110CFM 133 114 110 97 95 94 91 85 72 50 + • 950 1.14 SD.2 Sones 1.5 1.5 1.5 2.0 2.0 2.0 3.0 3.5 4.0 4.5 SP-6150 1050 1.70 128 CFM 160 156 155 154 152 149 147 138 123 92 Sones 2.5 2.5 2.5 3.0 3.5 3.5 4.0 4.5 4.5 5.0 SP-6200 1100 2.20 172 CFM 197 195 194 191 187 184 181 166 151 128 Sones 3.5 4,0 4.0 4.5 4.5 5.0 5.0 5.5 5.5 5.5 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B.free inlet spherical fan sone levels. Model SP-C e ---''\ Model SP-C Dimensions �f A Model A B C D E F Decorative Unit 1 D Grille Weight tounc 71/2 T/z 3s/a 3 1S/e 1/2 9'/a x 9 5 hr° i 50 "n (191) (191) (92) ps) (41) (13) (zasx22s) z) CI �� NVI All dimensions are in inches(millimeters)and weight in pounds(kilograms).For Y CERTIFIED complete dimensional information,see CAPS submittal drawings. Q *Note:Amp draw is approximate and may vary based on motor manufacturer. F ® US LISTED Model SP-C Performance Model HVI RPM Amps" Watts CFM/Static Pressure in Inches wg 0 0.1 0.125 0.25 0.375 0.5 0.625 SP-050 + 1680 0.80 46 CFM 52 49 49 47 44 38 29 Sones 3.0 3.0 3.0 3.0 3.5 4.0 4.0 Performance certified is for model SP exhaust for installation type 8:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. 14 Model SP-L and CSP-B F � Deluxe Inline Cabinet Fan Value, ' i " ' • • Model SP-L Model SP-L Dimensions �F''F~Ey r1 i Y ' Model A B C D E F Designer Unit ® �� sounn Grille Weight / B A D ..art d ©�- ..e 50,80 1 Vs(352) 11%2) 3%(92) 2%(67) 113 3%6 1478 x 37) 4) M V t (352) (292) ' (92) (67) (173) (86) (378x337) (4) CERTIFIED All dimensions are in inches(millimeters)and weight in pounds(kilograms). For complete dimensional information,see CAPS submittal drawings. C 0 US USTED `Note:Amp and watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. f Model SP-L Performance Model HVI RPM Amps" Watts* • CFM 0 - 0.1 -- 0.125 0.25 0.31 5 STAR0.5 _ 0.625 2 53 51 41 ENERGY Max. CFM/Static Pressure in Inches wg ar P Input 19 SP-L50 Zg' + 800 0.17 17.8 Sones 1.0 1.2 1.3 2.0 3.0 3.5 CFM/Watts 3.48 2.99 2.91 2.38 i 1.85 1.15 Watts 17.8 17.7 ' 17.5 17.2 16.8 16.5 CFM 86 78 76 67 57 46 33_ SP-L80 Y'- + 850 0.23 26.8 Sones 1.5 2.0 2.0 2.0 2.5 3.5 4.0 CFM/Watts 3.21 2.92 2.85 2.54 2.19 1.78 1.30 Watts 26.8 26.7 26.7 26.4 26.0 25.8 25.4 Performance certified is for model SP exhaust for installation type B:Free inlet.Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper. Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. Model CSP-B Inlet D - diameter Model CSP-B Dimensions FxG �\/ W ! ar orsnnfn Rnnncr Model ABCDEF G Unit ��O �) C �, Weight / ,�„o.rmrt 110,150,200 13% 11% 7 6 1 Ye 13'/2 3'/e 10'/. II I+ E (352) (292) (1 78) (152) (32) (260) (83) (5)_ bili All dimensions are in inches(millimeters)and weight in pounds(kilograms). 11‘, I� Inlet connection width is 1 inch(25 mm).Mounting bracket width is 1Y2 in.(38 mm). For complete dimensional Information,see CAPS submittal drawings. A . V C 00 US LISTED *Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model CSP-B Performance Max. CFM/Static Pressure in Inches wg Model RPM Amps* Input Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 CFM 103 100 100 98 97 96 94 86 CSP-B110 950 1.14 80 Sones 1.5 1.5 1.5 2.0 2.0 2.0 2.5 2.5 Watts' 92.3 92.2 92.2 92.1 92.0 92.0 91.9 91.4 CFM 151 150 149 148 144 146 142 135 CSP-B150 1050 1.70 129 Sones 2.0 2.0 2.0 2.0 2.5 2.5 3.0 3.0 Watts' 145.0 145.0 145.0 145.0 144.9 144.9 144.9 144.7 ----- CFM 186 184 184 182 181 179 175 170 CSP-B200 1100 I 2.20 ' 173 Sones 3.0 3.0 3.0 3.0 3.5 3.5 3.5 3.5 Watts* 183.0 182.4 182.4 181.8 181.5 180.9 179.7 178.2 Performance certified is for model CSP inline for installation type D:Ducted inlet,Ducted outlet.Performance ratings include the effects of a backdraft damper. Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type D:ducted inlet spherical fan sone levels.Ratings do not include the effect of duct end correction.Ratings are based on 10 ft of insulated duct. 15 Model CSP-A = ,,, ;rH , Premium Inline Cabinet Fan , �R ''� , in Air * �, '- Model CSP-A Dimensions CSP-110-510,510-VG, r%,, 710,710-VG,780 Model A B C D E F G Unit Weight 110,125,190 (37) ( 9 8 5 12 9Ya 16 G �4 (337) (270) (229) (203) (152) (305) (235) (7) 200,250,290, 14 1 P/s 11'/n 8 8 12'/a 10 23 r ► am 390 (356) (302) (286) (203) (203) (327) (254) (10) D• � � �� 410,510, 18 14% 141/2 8 8 16'% 13'/a 36Nikita. 510-VG,710-VG (457) (365) (368) (203) (203) (429) (337) (16) �V ,I /A 70Q,700-VG 23% 11% 11% 19'/z 8 22% 10'1 34 Ir (600) (295) (295) (495) (203) (575) (267) (15) 710,780 18 14'/a 14'/z 10 8 16'/a 13Ya 36 S CSP-700,700-VG, c U■ us ` p (457J (365) (368) (254) (203) (429) (337) (16) �� 1050-VG, �7 900,105Q (�A` 900-3600 1050-VG, 23"/< l4%s 14'/z lT/e 8 22% 13''/a 59 1410,1550 (603) (365) (368) (443) (203) (575) (337) (27) / I�� 1750,2150 35 (375) 14a/) 28 6 (832) 13 31 G I/ ~D (889) 14%1 (3 75) (78 (762) 323/4 (130) (31) 3600 16Yz 16Yz 40 11 14%(371) 122 F (1156) (419) (419) (1016) (279) (1099) (371) (55) All dimensions are in inches(millimeters)and weight in pounds(kilograms).Inlet and outlet connection widths are 1 in.(25 mm).Mounting bracket width is 1/ in.(38 mml. Inlet For complete dimensional information,see CAPS submittal drawings. s .trs Model CSP-A if ,� Premium Inline Cabinet Fan N * Valuer = '$' "Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model ax. Control RPM Amps* Input CFM/Static Pressure in Inches wg Voltage Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 1.25 CFM 124 112 110 102 77 CSP-A110 950 0.62 20 Sons 0.8 0.8 0.8 0.9 0.9 `Welts' 20.3 20.0 19.9 19.7 18.4 CFM 138 126 124 114 91 CSP-A125 1100 0.63 23 sows 1.1 1.1 1.1 1.o 1.2 Watts' 22.5 22.3 22.2 22.1 21.3 CFM 215 202 198 180 159 121 CSP-A190 1400 1.10 55 Sews 2.0 1.5 2.0 2.0 2.5 2.5 Watts' 55.1 54.1 53.7 51.9 49.8 46.0 CFM 254 231 226 203 178 145 109 70 CSP-A200 900 0.43 58 Sores 0.6 0.4 0.5 0.9 1.0 1.3 1.5 1.5 Watts" 57.9 57.3 57.1 56.1 54.6 52.5 50.3 48.0 CFM 266 246 241 221 205 187 165 132 CSP-A250 1000 0.79 67 Sones 0.9 1.0 1.0 2.0 2.5 3.0 2.5 2.5 Watts" 66.5 65.6 65.4 64.0 62.7 61.2 59.4 56.6 CFM 318 299 292 265 248 229 201 144 CSP-A290 1050 0.71 102 Ganes 1.1 1.2 1.3 2.0 2.5 3.5 3.0 3.0 Watts' 102.2 100.9 100.4 98.3 96.9 95.0 90.5 81.3 CFM 412 400 397 382 363 339 324 309 CSP-A390 1350 1.33 161 Sones 2.0 2.0 2.0 2.5 3.0 4.0 4.5 4.5 Watts' 160.8 158.5 157.9 152.4 147.9 141.8 135.4 130.0 CFM 447 441 403 364 317 217 CSP-A410 1000 1.87 132 Sones 1.5 1.5 1.5 2.0 2.0 2.0 Watts' 132.2 131.7 128.7 125.6 120.5 112.4 CFM 545 514 506 464 405 324 CSP-A510 1070 3.11 218 Sones 2.5 2.0 2.0 2.0 2.0 2.5 Watts' 218.2 214.3 213.3 207.0 196.4 182.8 CFM 428 358 338 238 850 0.86 55 Sones 0.8 0.6 0.5 0.3 CSP-A510-VG Watts' 54.8 48.9 47.0 35.8 CFM 621 590 583 540 479 414 328 1275 2.40 160 Sones 1.5 1.4 1.4 1.3 1.2 1.5 1.7 Watts' 154.4 159.6 160.1 156,1 140.7 123.1 99.9 CFM 766 755 752 739 726 702 678 635 549 418 CSP-A700 1100 3.20 352 Sones 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.5 4.0 Watts' 352.1 350.7 350.3 348.7 346.3 340.7 332.E 315.5 289.1 256.1 CFM 625 570 558 504 450 402 348 261 213 167 67 6 1275 1.83 110 Sones <0.3 <0.3 <0.3 <0.3 <0.3 0.8 1.1 1.5 2,0 2,5 3.0 CSP-A700-VG Watts' 55.6 58.7 60.0 63.5 69.4 76.5 83.8 89.5 95.3 101.0 108.2 CFM 895 857 848 803 760 725 688 647 604 556 479 10 1450 3.53 216 Sones 1.0 1.0 1.0 1.0 1.0 1.2 1.5 1.5 2.0 2.5 3.0 Watts' 157.1 160.6 161.3 168.5 169.4 173.1 179.9 187.1 193.6 201.4 215.3 CFM 737 698 688 635 567 475 334 CSP-A710 1080 4.40 333 Sows 2.5 2.5 2.5 2.5 2.0 2.0 2.0 'Ways' 332.5 324.1 322.0 310.8 295.8 277.4 255.2 CFM 470 415 405 322 925 1.08 68 Sows 0.6 0.4 0.4 0.4 CSP-A710-VG Watts' 67.8 61.2 60.6 49.0 CFM 730 699 690 654 622 574 514 446 349 1450 3.51 236 Sones 2.2 2.1 2.1 2,0 1.9 2.1 2.4 2.7 2.8 Watts' 236.0 234.2 231.4 223.1 218.9 200.8 180.0 156.8 119.9 CFM 813 784 777 742 707 672 638 603 567 527 CSP-A780 1600 3.77 496 Sones 3.0 3.0 3.0 3.0 3.0 2.0 3.0 3.0 3.0 3,5 Watts' 496,4 493.0 492.2 488.0 467.5 453.1 441.8 423,1 407,2 CFM 908 852 841 782 715 631 CSP-A900 950 4.87 335 Sones 1.4 1.4 1.4 2.0 2.5 3.0 Watts' 335.0 288,6 286.0 272.7 259.9 245.5 CFM 1182 1110 1093 1013 922 832 743 CSP-A1050 1095 6.65 469 Sones 2.5 2.5 2.5 2.5 2.5 2.5 2.5 Watts' 468.8 455.9 453.3 440.8 424.9 411.0 399.2 CFM 805 754 741 689 642 597 547 6 1050 1.90 115 Sines <0.3 <0.3 <0.3 0.4 0.5 1.0 1.5 CSP-A1 D50-VG Watts" 79.8 85.2 85.0 91.4 97.4 105.5 114.9 CFM 1131 1105 1092 1047 998 900 758 10 1225 3.85 241 Sows 1.0 0.9 0.9 1.0 1.2 1.3 1.4 Watts" 220.7 231.5 231.5 239.7 239.9 216.7 173.9 CFM 1584 1543 1533 1483 1439 1395 1345 1293 1238 1181 CSP-A1410 1450 7.80 871 Sones 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 4.0 4.0 Wens' 870.8 837.9 829.9 788.2 751.0 728.3 696.3 661.8 628.8 595.9 CFM 1672 1618 1604 1543 1484 1427 1367 1307 1240 1172 CSP-A1550 1610 8.32 913 Sones 5.0 4.5 4.5 4.5 4.5 4.0 4.0 4.5 4.5 4.5 Watts' 912.8 877.4 868.4 829.3 802.9 778.0 744.3 710.7 679.1 647.4 CFM 1842 1768 1749 1619 1464 1284 1032 772 484 CSP-A1750 1130 6.60 600 Sates 5.0 5.0 5.0 4.5 4,0 4.0 3.5 3.0 3.0 Watts' 599.8 570.5 563.0 515.0 470.9 420.3 366.1 317.2 276.5 CFM 2249 2175 2156 2044 1900 1701 1424 1114 CSP-A2150 1100 7.80 761 Ganes 5.0 4.5 4.5 4.0 4.0 4,0 3.0 3.0 Watts' 760.8 731.5 724.0 679.7 622.7 544.0 459.7 382.3 CFM 3778 3653 3622 3460 3280 3091 2844 2551 2232 1750 CSP-A3600 1100 7.10 1314 Sones 5.0 5,0 5.0 5.0 4.5 4.0 4.0 4.0 3.5 3.5 Watts' 1313.7 1253.3 1238.3 1160.0 1084.0 1041.5 971.1 871.9 766.5 649.5 Performance certified is for model CSP inline for installation type D:Ducted inlet,Ducted outlet.Performance ratings include the effects of a backdraft damper. Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type D:ducted inlet spherical fan sone levels.Ratings do not include the effect of duct end correction.Ratings are based on 10 ft of insulated duct. 17 Model SPin 114V. f YH �` 50 Cycle Performance inAir `` • For uses in countries with 50 cycle (50 Hz) power, SP-A 110-510,510-VG, Greenheck offers the same reliability and performance 710,710-VG,760 for ceiling mounted exhaust fans model SP. B/h A • Same dimensions and outlet options r \ • Performance shown in 50 cycle RPMs 1 E • Full-line of grille and discharge accessories available �p� Model SP Dimensions SP-A 700-VG,1o50-VG, SP-A A BCDE Designer Decorative Unit 900-1550 Grille Grille Weight B .1' 110,125,190 137 10% 9 8 6 17 f A (337) (270) (229) (203) (152) 14%x 131/4 15%(387) (8) t �\ 200,250,290,390 14 11% 11% 8 8 (378 x 337) square 24 / E v (356) (302) (286) (203) (203) (11) '' � 410,510, 18 14% 141/2 8 8 19'%x 16% 31 C .D 510-VG,710-VG (457) (365) (368) (203) (203) (492x416) (14) 700-VG 23% 11% 11% 191/28 251/e x 13'/ 34 (600) (295) (295) (495) (203) (638 x 343) (75) 710,780 18 14% 14Yz 10 8 19%x 16% 34 (457) (365) (368) (254) (203) (492 x 416) (15) 900,1050,1050-VG, 23% 14% 141/2 18'/8 8 25 x 16% 56 1410,1550 (603) (365) (368) (476) (203) (635 x 416) (25) SP-B 50-200 Outlet connection width is 1 in.(25 mrn).Mounting bracket width is 17r in.(38 mm). f B/•�A Designer Decorative Unit } SP-B A BCDE / �� D C Grille Grille Weight 13'% 11% 7 6 1'% 14'/a x 13Y4 9 50,70,80 352 292 178 752 32 (378 x 337 4 �ii -i ( ) ( I ( ) ( ) 15'/a(387) ii e. �� 150,200 1 7 (6) (32) 1(378 x 337) square 1(31 0 ��i��%�%why (352) (292) (152) (152) dimensions are in inches(millimeters)and weight in pounds(kilograms).Mounting bracket width is 11/2 in.(38 min).For complete dimensional information,see CAPS submittal drawings. *Note:Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 220-240V. Model Control Max. CFM/Static Pressure in Inches of wg (50 Hertz Motor) Voltage RPM Amps' Input 0.000 0.050 0.100 0.125 0.150 0.250 0.375 0.500 Watts* SP-A710 950 0.29 49 CFM 119 115 110 106 103 88 Sows 1.3 1.3 1.2 1.2 1.3 1.6 SP-A190 1400 0.e5 113 CFM 216 206 197 192 187 167 133 Sonar 3.2 3.0 2.8 2.9 2.9 3.1 3.4 SP-A290 1050 0.36 81 CFM 329 315 302 296 290 262 222 164 Soros 3.2 3.3 3.3 3.3 3.4 3.7 4.0 4.9 SP-A390 1350 0.67 135 ChM 410 402 395 392 387 368 345 325 Sones 5.4 5.4 5.4 5,4 5.5 5.7 6.0 6.3 SP-A510 900 1.65 2QQ CFM 447 425 400 388 376 315 159 Sones 3.7 3.5 3.3 3.3 3.3 3.1 2.6 850 0.75 qg CFM 399 375 354 341 320 255 SP-A510-VG Sones 4.5 4.3 4.0 3.9 3.7 3.4 1275 2.40 155 CFM 604 595 583 576 567 540 495 443 Sones 7.9 7.8 7.7 7.7 7.5 7.3 7.0 6.8 6 1275 1.82 111 CFM 568 548 527 517 492 466 419 372 Sones 3.5 3.5 3.5 3.5 3.5 3.5 4.0 4.5 SP-A700-VG CFM 801 788 774 766 748 729 699 666 10 1450 3.52 218 Sores 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 925 0.96 60 0717 441 425 410 397 379 327 SP-A710-VG Sores 4.5 4.4 4.3 4.2 4.2 4.0 1450 3.39 230 car,' 709 697 685 677 671 656 621 580 Sores 9.6 9.5 9.4 9.2 9.2 9.0 8.7 8.6 SP-A780 1334 1.65 348 CFM 677 659 642 633 625 591 544 493 Sones 8.8 8.9 8.8 8.7 8.6 8.2 8.1 8.1 SP-Al 050 950 3.15 420 0FF! 990 945 905 886 867 769 531 Sones 7.2 7.0 6.8 6.8 6.8 6.6 6.5 6 1050 1.94 120 007 838 814 789 779 757 735 685 632 SP-A1050-VG Sones 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 10 1225 3.75 240 GEM 1162 1134 1106 1092 1058 1023 944 831 Sones 7.5 7.5 7.0 7.0 7.0 7.0 6.5 6.0 SP-A1550 1340 4.3 818 CFM 1337 1314 1290 1279 1266 1211 1161 1112 Sones 11.1 10.7 10.6 10.6 10.6 10.5 11.6 13.5 CFM 102 97 92 88 86 75 59 45 SP-B90 700 0.325 50 Saner 1.9 2.2 2.6 2.7 2.7 3.0 3.6 4.1 SP-B1,0 950 D.57 g0 CFM 133 124 114 110 107 97 95 94 Sones 2.0 2.0 2.1 2.2 2.2 2.4 2.7 2.8 SP-B150 1050 0.85 129 CFM 160 158 156 155 155 154 152 149 Sanes 3.0 3.1 3.3 3.3 3.4 3.7 4.3 4.5 SP-B200 1100 1.1 173 CFM 197 196 195 194 194 191 187 184 Sates 4.4 4.7 4.6 4.7 4.9 5.1 5.6 5.8 18 r Model CSP 50 Cycle Performance = � : value', i►�� -p For uses in countries with 50 cycle (50 Hz) power, CSP-A 110-510, 510-VG, Greenheck offers the same reliability and performance 710,710-VG,780 for inline cabinet fans model CSP. F/^ • Same dimensions and outlet options T • Performance shown in 50 cycle RPMs /) 61 • Full line of discharge accessories available t 11 1 Model CSP Dimensions CSP-A 700-VG,1050-VG ` , > CSP-A A BCD E F G Unit 900-3600 I g A WeightEt' �� 110,125,190 13Y4 10% 9 8 6 12 9 16 f (337) (270) (229) (203) (152) (305) (235) (7) I411 1��AA,,,.200,250,290,390 G 14 11% 11'/4 8 8 12% 10 23 I I`� (356) (302) (286) (203) (203) (327) (254) (10) l� � 410,510, 18 14% 141/2 8 8 16% 1314 36 D 510-VG,710-VG (457) (365) (368) (203) (203) (429) (337) (16) r4401 700-VG 230E 11%95 11%9 (95) 8 22% 10Y) 34 \ (600) (295) (295) (ass) (203) (575) (267) (1s) 710,780 18 14% 14'/ 10 8 16% 13Y4 36 (457) (365) (368) (254) (203) (429) (337) (16) Inlet 900,1050,1050-VG, 233/4 14% 141/2 183/4 8 22% 133/4 59 1410,1550 (603) (365) (368) (476) (203) (575) (337) (27) CSP-B 1750,2150 35 14'/4 14% 28 6 32'/4 13 68 Inlet D-diameter (889) (375) (375) (711) (152) (832) (330) (31) FxG 3600 45% 16'/ 16'h 40 11 43/4 14% 122 (1156) (479) (419) (1016) (279) (1099) (371) (55) 1 CSP-B A BC DE F G Unit ( l` ��1)Weight I \\�� ` E 110,150,200 13%52) (12) 7 6 ('2) (6'0)) 3(83) 1(5) 6 (352) (292) (178) (152) (32) (260) (83) (5) All dimensions are in inches(millimeters)and weight in pounds(iilograms).Inlet and outlet connection widths are 1 in.(25 mm).Mounting bracket width is 1'V2 in.(38 mm). \� For complete dimensional information,see CAPS submittal drawings. *Note:Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 220-240V. Model Control Max CFM/Static Pressure in Inches of wg (50 Hertz Motor) Voltage RPM Amps* Input 0.000 0.050 0.100 0.125 0.150 0.250 0.375 0.500 0.625 Watts* CSP-A110 950 0.31 51 CFM 124 116 112 110 109 102 77 Sones 1.1 1.1 1.1 1.1 1.1 1.3 1.3 CSP-A190 1400 0.55 100 CFM 215 202 198 180 159 121 Sones 2.3 2.0 2.2 2.7 2.9 3.0 CSP-A390 350 0.67 144 CFM 412 400 397 382 363 339 324 309 Sones 2.8 2.7 2.8 3.2 3.7 4.7 5.5 6.5 850 0.86 55 CFM 428 393 358 338 313 238 CSP-A510-VG Sones 0.8 0.7 0.6 0.5 0.5 0.3 1275 2.40 160 CFM 621 605 590 583 572 540 479 414 328 Sones 1.5 1.5 1.4 1.4 1.4 1.3 1.2 1.5 1.7 6 1275 1.83 110 CFM 625 598 570 558 531 504 450 402 CSP-A700-VG Sones <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 0.8 10 1450 3.53 216 CFM 895 876 857 848 826 803 760 725 Sones 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 925 1.08 68 CFM 470 443 415 405 384 322 CSP-A710-VG Sones 0.6 0.5 0.4 0.4 0.4 0.4 1450 3.51 236 CFM 730 715 699 690 681 654 622 574 514 Sones 2.2 2.2 2.1 2.1 2.1 2.0 1.9 2.1 2.4 CSP-A780 1334 1.89 405 CFM 685 656 648 609 562 520 461 Sones 5.0 4.9 4.8 4.7 4.6 4.7 4.9 CSP-A1050 950 3.33 455 CFM 1079 1031 982 957 934 841 655 Sones 6.3 6.3 6.0 5.9 5.9 6.0 5.5 6 1050 1.90 115 CFM 805 780 754 741 715 689 642 597 CSP-A1050-VG Sones <0.3 <0.3 <0.3 <0.3 0.4 0.4 0.5 1.0 10 1225 3.85 241 CFM 1131 1118 1105 1092 1070 1047 998 900 Sones 1.0 1.0 0.9 0.9 1.0 1.0 1.2 1.3 CSP-A1550 1340 4.16 830 CFM 1391 1326 1311 1240 1171 1098 1019 929 Sones 7.5 7.4 7.4 7.3 7.4 7.3 7.3 7.2 CSP-B110 950 0.57 80 CFM 103 102 100 99 99 98 97 96 93 Sones 2.0 1.9 2.0 2.1 2.1 2.3 2.6 2.7 3.1 CSP-B150 1050 0.85 129 CFM 151 150 149 149 149 148 148 145 142 Sones 2.5 2.7 2.7 2.7 2.7 2.9 3.1 3.4 3.6 CSP-B200 1100 1.1 173 CFM 186 185 184 183 183 182 180 178 175 Sones 3.4 3.7 3.6 3.7 3.7 4.0 4.1 4.1 4.3 19 , Accessories - h r - • ":- ` in Air Wheel Options SP-B Replacement Power Packs Greenheck's ceiling and cabinet fans (models SP Save installation and down time by replacing the entire and CSP) deliver high performance from a forward- power pack instead of individual components. Available curved wheel. The forward-curved wheel design offers as a replacement part on both high-efficiency and low sound. Fan wheels are all current and previous constructed of polypropylene or steel as standard, and SP-B models. most models offer an aluminum wheel option. • Level A models utilize steel or polypropylene (standard)wheel construction depending on size. • Level B and L models are standard with a polypropylene wheel. I C. Polypropylene .._ -1 Contractor 4 Packs Save installation time and labor by installing the housing first,then installing the internal components after the sheetrocking, plastering and finishing is done. Housings are packaged in one box, power assemblies and grilles are packaged in another box. Components are shipped to coincide with the phase of your project. Steel Aluminum (Model SP-B and SP-L series). «l. • Niii, t �'A „ - ''N , ...: :-. ilk' •It ' „ -I • y Pelf w t F' '� ' ti ~ p. Al r ,,, *x' ".;... Accessories Grille Options Lighted Grille Options Designer(Standard) Greenheck's fan and light combinations include either a Available in white prismatic or a frosted lens with LED lamp. Our unique polystyrene finish, with light box is manufactured with a reflective material to optional motion humidity increase the light given off by the LED lamp. UL Listed or combination sensors. for above bathtub and showers with GFCI branch All optional sensors have protected circuit. time delay functionality as standard. Model SP-A, sizes 50 - 390 Available on A50-A390 and B50-B200.No grille Model SP-B, sizes 50 -200 mounted sensors available on the SP-L50 and SP-L80. Note: When selecting a lighted grille it will add height to Aluminum a the fan assembly. See CAPS drawings for exact values. White enamel finish standard for 1 models A410-A1550. :, - Optional for models A50-A390 and -Its Prismatic Lens B50-B200. The prismatic lens design provides approximately 25% more light than a 111 II Stainless Steel traditional frosted lens.The lens may be Polished stainless steel finish optional , easily removed to replace light bulbs. ti for models A50-A390 and B50-B200. s1 Frosted Lens _ The frosted lens option is a traditional Decorative design which lets approximately 80% I II White plastic finish,with or without of light through the lens.The lens may light, motion detector with time delay. be easily removed to replace light _ Optional for models A50-A390 and bulbs. _ B50-B200. I '"` Note:Our LED light bulbs are ENERGY STAR®certified. Not all fan/lighted grille options are Architectural Grilles ENERGY STAR®certified. See CAPS for availability. Aluminum, powder coated paint. aA-747A1 Available on A50-A390 and L•ii �i -1 LED B50-200. A i�� �ra0-a � �, • GU24 Base • 85% more efficient than "' • 25,000 hour life incandescent • Reflective light box Custom Molded polystyrene available in an array of colors. Includes all the same accessory options as the standard grilles. For more information on the many ways this grille option can be used, please contact your Greenheck representative. 411111110110111 Customized Grille Lens Lenses can be customized -- .,' with formed shapes ter . or logos. Contact your • Greenheck representative .. for details. 21 Accessories I ;'- 1H .y Filters Hanging Vibration Isolators Fans used in most applications will collect airborne dirt Vibration isolator kits are available for suspended on wheels and motors over time, even where air is not installations. Kits include all hardware necessary to excessively dirty. Accumulations of dirt on the fan wheel mount one unit, with the exception of 1/4-20 threaded will sharply reduce performance and cause imbalance. rod to be supplied by others. Fan mounting brackets Dirt buildup on the motor can cause it to overheat.All of include prepunched these conditions will shorten the life of the fan.To help mounting holes for A reduce this accumulation, washable aluminum mesh ease of installation. I'' B filters are available to trap dirt before it enters the fan. These filters should be regularly cleaned to maintain 1/4-20---4' hanging performance.The Filter Loss Chart below shows the support effect the filter will have on performance.To determine rod by others the added resistance, divide the desired cfm by the filter MI area(ft2). This will give ft/min. Use this with the filter loss chart to get the 0 -added resistance. �j�r'������"/f/'/ll�,j'I"I `101 � Filters reduce Mesh 7l` r..--- sound levels, in Filter \\\\ ��-::":-���� addition to reducing ����������������������� Unit Size A B dirt accumulations ����������\\ On the motor and SP B50-B200 4'/(774) 15%(397) Wheel. Grille A50-A190 51/2(140) 15(381) A200-A390 6%(171) 15%(400) Filter Loss Chart A410,A510,A510-VG,A710,A710-VG,A780 91/4(235) 19'/(502) Filter Model A700,A700-VG 5/ (140) 25%(645) SP Model Filter Designer *Metal Area(ft') A900,A1050,A1050-VG,A1410,A1550 91/2(235) 251/2(648) Grille Grille ------- SP-A50-A190 F-200 F-210 0.739 A1750,A2150 9'/4(235) 36%(933) SP-B50-B200,A200-A390 F-200 F-220 0.911 A3600 91/4(235) 471/4(7200) SP-A410-A510,SP-A510-VG, All dimensions shown in inches(millimeters). SP-A710-A780,SP-A710-VG i NA F-250 1.518 SP-A900-A1550, NA F-260 2.D78 SP-A1050-VG Model RDC - Round Duct Connector *Aluminum or Stainless Steel Grille. • Replaces the standard square discharge Transition Duct Reducer duct connector and RDC-8 damper • Durable plastic construction `'o 6,,32 • Uses existing 0s) mounting holes IA ��%A • RDC-6 includes a damper ��► 3, (polypropylene . bo0) 4 o) nz 019 • construction) i • RDC-8 does not include a damper (galvanized Model For use with sizes: construction) 473324 B50 B200 A50-A90 I Model I Use with sizes: Diameter 6x4 Reducer A110-A190 481734 RDC-6 A110-A190 6(152) L50,LB0 A200-A510 4x3 Reducer RDC-8 8(203) _..__. ___ _....._. -. __... _.... A510-VG,A710-VG All dimensions shown in inches(millimeters). *Used In conjunction with RDC-6 for SP model sizes A110 thru A190 All dimensions shown in inches(millimeters). 22 Accessories value Ai.' .�;. Ceiling Radiation Damper The National Fire Protection Association (NFPA) E D��c RJ-4 and RJ-6x9 �.. Standard 90A requires openings in fire rated ceiling j �' assemblies to be protected by appropriately rated ceiling radiation dampers. As a result, many local codes require fans installed in fire rated ceilings to be D C A � protected by dampers which are insulated against both \A— B� heat and flame. �„/ Greenheck's ceiling radiation dampers are also Warnock Hersey Listed to go into a one hour E RJ-10x10 combustible (wood) installation. Greenheck's UUcUL B Classified ceiling radiation dampers are rated for three A hours of fire resistance in a steel/concrete installation. Model RJ - Pitched Roof Cap Model SP-A • Steel construction with black enamel finish SP-A Fan • Integral flashing flange Hanging • Built-in birdscreen and damper Vibration -- __.. _. Isolation i !* Model Use for sizes: A B C D E Throat ce, Ceiling 80,80L,C50, 11 91/2 8' 5%16 41/2 4(102) Radiation RJ-4 B50-B80, L50,L80 (279) (235) (270) (135) (114) diameter Damper - -_.... , 110,100L, 3 in. Fire RJ-6x9 B90-8200, 18%i 14% 1412 110% 6'hz 6 x 9 �� � Rated A50-A390 (476) (362) (368) (264) (165) (752 x 229) Ceiling AxB r I"-Grille -__ _--- A410-A1050 Model SP-B RJ- A510-VG, 182 271/2 15%', 23%19'/ 10 x 10 10x10 A700-VG,A710-VG, (470) (699)I(400) (600) (241) (254 x 254) � r All dimensions shown in inches(millimeters). � SP-B Fan di - �`---- 4000'00, Hanging ,--r "'Vibration - ^-\ IMM- Isolation Ild Ceiling Radiation Damper 10 11.125 (254 (283) i Fire 3 in. a"Rated ±_ ' Ceiling 3.5(89)— I- AxB -I"-Grille 2.875(73) ' 9.375 SP Model CRD Length(A) Width(B) Height UL W.H. 6.5(165) (238) A50-A190 310 13'h j 11 3 310 310 1.625(42)- (343) (283)3) (76) 310E j B50-B200 14% 12% 3 320 3.375(86) LA200-A390 320 (365) (311) (76) 320L 320 /jam/ i A410-A510 l i `11.25 i A510-VG, 18%,c 14'/s 3 5.125 A710-A780 1350 (468) I (379) (76) 350 350 (130) (292) A710-VG All dimensions shown in inches(millimeters). A700,A700-VG 700 24'/,s 121/4 3 700 NA (614) (311) (76) Model EL-10x3 - A900-A1550, 360 24'/,e 14's/s 3 360 360 I Elbow Discharge with Grille Al 050-VG (614) (379) (76) I I g All dimensions shown in inches(millimeters).Add an"L"to all CRD models if • Designed for installation under roof eaves fan&light combo is used.'CRD is approximately 1/4 inch(6 mm)larger than housing dimension.(See Installation,Operation and Maintenance Manual). • Black epoxy finish (elbow and grille) c>psslf7Fo ® • Built in damper C US ° • SP and CSP sizes 50-290 Intertek 23 Electrical Accessories ' �W— •' ' ^in Air °t ; Dehumidistat Speed Controls Dehumidistats are available as a wall Speed controls may be used on model mount switch or integrated to the fan. SP and CSP fans for manual adjustment Each sensor automatically detects of the fan's performance(for final system excess humidity to help control fir! balancing)or to control the fan's output in condensation. confined spaces, such as conference or Wall switch: meeting rooms.The fan can be adjusted Rated for 120V, 3A, 1/6 HP s..• to 60% of design airflow with a speed • control. This reduction in airflow and fan • UL Listed - speed is also accompanied by a reduction Integrated switch to fan: in noise level. Solid state speed • Available on 115V controls are available for a range of - SP-A50 thru SP-A390 applications up to 15 amps. Speed - SP-B50 thru SP-B200 controls can be used to operate more than one fan if the combined total amperage of the fans does not exceed the control rating. Internal Mounting SPEED CONTROL INTERNAL AND/OR EXTERNAL MOUNTING OPTIONS Model FAN SIZES Voltage Rating — -- Amp Rating 50 70 80 90 110 125 150 190 200 250 29D 390 410 510 700 710 780 900 1050 1410 1550 1750 2150;,3600 6WSSC 115-127V I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E NA NA NA NA NA NA 6Amp 10WSSC 115-127V E E E E E E E E E E E E E E E E E E E E E E E NA 10 Amp 1 15WSSC 115-127V E E E E E E E E E E E E E E E E E E E E E E E NA 15 Amp 5W240 220-240V NA NA NA 'I/E I/E NA I/E I/E "I/E NA I/E I/E NA I/E NA NA I/E NA I/E NA I/E NA NA NA 5 Amp _.1.---1 t- --i ------ ! a I _.. I ±-- SWSSC 220-240V NA NA NA 'E E NA E E *E NA E E NA E NA NA E NA E NA E NA NA NA 8 Amp 5W277 227V NA NA NA NA I/E I/E I/E I/E "I/E NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 5 Amp E=External mounted only I/E=Available Internal and External Mounted KEY: "Only available on the B-series(A-series is not available) NA=Not available NOTES: Speed controllers are not available for 208V applications. SP-050 speed controller is shipped loose only. All speed controller options listed in table are UL Listed. Handy box sizes are 2x4 for all options above except 1 OWSSC and 15WSSC,which are 4x4. Speed controller Is not compatible with SP-A50-90-VG and SP-A90-130-VG Thermostat Reverse Acting Adjustable for temperature ranges between " • UL Approved 30°F to 110°F(-1°C to 43°C), 120V, 16 amp • CSA Certified Cooling • 120V, 22 Amps When the temperature in the space rises above the set point of 50°F to 90°F(10°C to 32°C)the contacts close and the thermostat will signal the fan to come on in order to exhaust air from the space. 24 •� w h Electrical Accessoriesiff s;. value it Switches Motion Detectors Switches may be used on model SP and Motion detectors may be used CSP fans to enable manual control of your i with SP and CSP fans or fan fan or fan and light combination. 1 and light combinations. Motion 1. II detectors use a passive infrared 1 Function 1motion detector to automatically Single pole rocker switch assembly turn the fan on when a change • Rated for 120-277V, 15A r.-- ----4 in motion is sensed. They have • UL Listed a viewing area of 180 degrees, however they must be placed in 1 Function with Pilot Light Ell the line-of-sight. — -- Single pole light combination switch - assembly Grille Mounted • Rated for 120V, 15A — Available on models up through , Awailissavii size SP-A390 and SP-B200. r i 0 • UL Listed • Rated for 115V ..}w- -=-x. 2 Function • UL Listed Two single pole combination switch 1 Wall Mounted assembly For use on fan or lights. Available • Rated for 120V, 15A shipped loose. • UL Listed • Rated for 115V • UL Listed Time Delay Switch • Requires 2x4 handy box - 1 • Time delay can be set for Time delay switches save energy by 30 seconds to 30 minutes in automatically turning off equipment. They L. 5 minute increments may be used with SP and CSP fans or , fan and light combinations for extended ; II— operating time of fan. Time delay switches Firestat act in the same manner as a standard • 120V, 8 Amp to 120V, switch, however,there is a delay of 10 to 4 Amp capacities 60 minutes after the fan has been turned off. • Max element temperature of 1 Minimum Ventilation Control 350°F(177°C) This control contains a microprocessor • Type II -5 inch insertion that monitors the operation of the fan to • Type Ill -111/2 inch insertion make sure that the space is receiving the ■ correct amount of ventilation per ASHRAE 62.2 Transformers • 120V,2.5A Transformers are available for • UL Listed applications requiring voltage '--_1 Via reduction. Selection is based on motor amperage. All transformers are shipped loose. See performance + pages for motor amp ratings. Models Voltage Ratings Amp Ratings T-2.0 230/277V to 115 2.0 Amps T-4.3 230/277V to 115 4.3 Amps Note:All switch covers are standard white. Other colors available upon request. 7 8.6 230/277V to 115 8.6 Amps T-6.5 230/277V to 115 6.5 Amps 25 Discharge Accessories ri 1 ;�`YH , - -:? - in A ::: ,-...-...., :,ir. Model WC - Hooded Wall Cap Model WC - Hooded Wall Cap (Round Connection) (Square or Rectangular Connections) • Aluminum construction - aluminum finish • Steel construction with black enamel finish • For outside wall applications • For outside wall applications • Built-in birdscreen (not available on WC-4) • Built-in birdscreen and damper and damper —C B ----- A C '1114 C , l A EI, '''lD1,, y� :; Model Recommended A B C D E Model Recommended A BCD E F G Sizes Sizes WC-4 iC50, L50,L80 61/2 1 6 1 4 4 5 i WC-10x3 50-290 51/4 12' 3/2 101/4 11'/ 41/4 5 -_--_- (165) (152) (101) _..(101) (127) (140) (324) (89) (260) (283) (108)1(127) WC-6 B50-8200,80, SOL 8 8 6 4', 5 WC-8x8 200 510 10'/ 10'/4 18% 8'% 81/4 6% 5 A50-A190, 110,100L (203) (203) (152) (105) (127) (260) (260)'plot (210) (210) (171) (127) __ 11 1 11 88 WC-8 A200 A510 5% 3/x WC-18x8 700-1550 10/4 20/4 SYa 18/4 6'/4 5 (279) (279) (203) (130) (89) (260) (514) (210) (464) (464)464) (171) l(127)j All dimensions shown in inches(millimeters). All dimensions shown in inches(millimeters). Model WL - Wall Louvered Discharge Model BVE - Brick Vent • Anodized aluminum grille • Designed for installation in masonry walls • Built-in damper • Anodized aluminum construction • Not recommended for exterior applications exposed • Built-in aluminum mesh insect screen to severe weather conditions. An external wall louver is recommended for such applications. A—J—... C/-I < % _ o � <II: ::- - NI, Model Recommended A B C D E Model Recommended A B C Sizes Sizes 12 3(3 5) (13 ) (26)4_(197) 8'9) - __.._(206) + (119/7). _ I (102). WL-10x3 50-290 BVE808 50-290 WL-18x6 390-1550 9/4 8 18 9 6 BVE128 390-510 12 7% 4 (502) (203) (457) (229) (152) 1 (305) (197) (102) n (millimeters). 700-1050 155/a T/, 4 All dimensions shown in inches BVE157 15% , (7% _. _-_ 102 _1 ) ( / All dimensions shown in inches(millimeters). 26 „ Discharge Accessories a Model RCC-7 - Curb Cap Model GRS - Curb Cap • Weathertight aluminum B • All aluminum exterior construction construction r Th. , • Galvanized steel internal B • Integral birdscreen l —IC supports • Built-in curb cap -Dia- D • C Integral birdscreen p-j t • Requires roof curb I I_ �3� • Built-in curb cap Dia. I�1-75 I—A—1 -f (44) • Requires roof curb A For all Throat For all Throat Model sizes: A B C D Dia. Model sizes: A B C D Dia. RCC-7 50-390 15(381) 12(305) 10(254) 6%(162) 7(178) GRS-10 410-710 19(483) 201/2(521)73/(197) 2(51) 101/4(260) All dimensions shown in inches(millimeters). GRS-12 780-1050 22(559) 29(737) 10(254) 31/2(89) 121/4(311) GRS-16 1410-2150 26(660) 29(737) 11 (279) 4'/4(108) 165/16(414) 1 GRS-20 3600 30(762) 35%2(902)11 Y(28e) 33/4(95) 20'/,5(516) All dimensions shown in inches(millimeters). Model GRSF - Flashing Flange •All aluminum exterior construction B Model RFC-7 - Flashing Flange • Galvanized steel internal } • Weathertight aluminum I B supports ISE i construction • Integral birdscreen • Integral birdscreen I _� I Dia. • Built-in flashing flange A • Built-in flashing flange -Dia.` r Model For all A B C D Throat I ` sizes: Dia. h A—1 GRSF-10 410-710 23(584) 201/2(521) 7144(197) 2(51) 10144(260) GRSF-12 780-1050 26(660) 29(737) 10('254) 31/2(89) 12%(311) Model For all A B C D Throat _ ----- sizes: Dia. GRSF-16 1410-2150 30(762) 29(737) 11(279) 41/4(108) 1654s(414) RFC-7 50-390 18(457) 12(305) 10(zsa)6%(162) 7(ns) GRSF-20 3600 34(864) 35/y02) 1114(286)1 3%(95) 120k5(516): All dimensions shown in inches(millimeters). All dimensions shown in inches(millimeters). Accessory Pressure Drops 0 !Al NI , il ;-. . , The chart to the right can be used with all of the _..i.._ .... .. _ 20 i discharge accessories shown on pages 23, 26 and 27. wL-,sxs Specific pressure drop values for these accessories _i _ R4-1 ox,o must be included in total system calculations for proper g 1eiiii■■ 1■■ 11p4 rI■ BVE-157, fan selection. . e—e��nommaloiwiliiiinVa WC-18x8 5_____ ■uppri_ %p■....BVE-128, e■Ypleid■M:� EMA ■ 21x8 5 -IIl/lil12ll= AAIP®....We 10x3, T' 5 MIIM'/„'1MP-ES.. WC-6, 4 1/1111®„11111=®®11® RJ-6x9, BL-10x3. WL-10x3, 3 i� iill0e�INE RFC RCC-7 2 ri1HIIIIRa .01 .02 .03 .04.05.08.07.08.09.10 Pressure Drop(Inches wg) Above accessories tested with 4 feet of inlet duct 27 Specifications ;; Vari-Green® °4 : in Air y" Vari-Green Control - Indoor Air Quality- tAirtir # Temperature / Humidity Control to be a packaged indoor air quality control designed to regulate fan speed based on level of temperature and/or relative humidity in a space. Control it shall include a Proportional Integral Derivative(PID) feedback loop and shall have labeled terminal strips for easy wiring. Fan shall be direct drive including an electronic commutation (EC)Vari-Green Motor. Control package shall be Vari-Green Indoor Air Quality— Temperature/Humidity Control. Vari-Green Motor Motor to be an electronic commutation (EC) motor Vari-Green Control - Indoor Air Quality— specifically designed for fan applications. AC VOC (Volatile Organic Compound) induction type motors are not acceptable. Examples Control to be a packaged indoor air quality control of unacceptable motors are: Shaded Pole, Permanent designed to regulate fan speed based on level of Split Capacitor(PSC), Split Phase, Capacitor Start VOC concentration in a space. Control shall include a and 3 phase induction type motors. Motors shall be Proportional Integral Derivative(PID)feedback loop and permanently lubricated with heavy-duty ball bearings shall have labeled terminal strips for easy wiring. Fan to match the fan load and prewired to the specific shall be direct drive including an electronic commutation voltage and phase. Internal motor circuitry shall (EC)Vari-Green Motor. Control package shall be convert AC power supplied to the fan to DC power to Vari-Green Indoor Air Quality—VOC Control. operate the motor. Motor shall be speed controllable down to 20% of full speed (80% turndown). Speed Vari-Green Control -Constant Pressure shall be controlled by either a potentiometer dial Control to be a packaged constant pressure control mounted on the motor or by a 0-10 VDC signal. Motor designed to regulate fan speed based on demand. shall be a minimum of 85% efficient at all speeds. Control shall include a Proportional Integral Derivative (PID)feedback loop and shall have all components Vari-Green Control - Remote Dial prewired to labeled terminal strips for easy wiring. Remote Dial shall be a Vari-Green Control specifically System shall include the appropriate pressure tap and designed to provide 0-10 volt DC signal to Greenheck's preset pressure transducer. Fan shall be direct drive Vari-Green Motor. including an electronic commutation (EC)Vari-Green Motor. Control package shall be Vari-Green Constant Vari-Green Control - Two Speed Pressure Control. Two speed control shall be a Vari-Green Control Indoor installations shall include pressure tap specifically designed to allow the Vari-Green Motor (duct or room)and control box with integral to operate at two discrete speeds.Two speed control pressure transducer. shall include two dials that may be set at any point Outdoor installations shall include duct pressure tap, between 0 and 10 volts DC and an integral transformer pressure transducer,and control box. Control box shall capable of reducing 115/208-240 volt AC power to be prewired and in a NEMA-3R weather tight enclosure 24 volt AC power. for mounting outdoors near the fan location. LEED information Greenheck became one of the first The Vari-Green®motor significantly helps manufacturers in the Air Movement qualification efforts for the Energy and Atmosphere lir and Control industry to join the LEED/ credits and prerequisites;specifically credit one, green movement when they joined the United Optimize Energy Performance and prerequisite two, States Green Building Council (USGBC) in Minimum Energy Performance. 2005. Greenheck has been actively researching qualification requirements for our products to meet LEED credits and prerequisites. 28 Van -Green® _if , EE-.M Model Specifications `�' p x. r Value in ai► I* ,.. , ti.. ,, _- . s: „....... Models SP-A50-90-VG and SP-A90-130-VG Ceiling mounted exhaust fans shall be of the centrifugal direct drive type.The fan housing shall be constructed of heavy-gauge galvanized steel.The housing interior shall be lined with 0.5 inch acoustical insulation.The outlet duct collar shall include a plastic backdraft damper. Outlet shall be adaptable for horizontal or vertical discharge.The designer grille for sizes SP-A50 through SP-A390 shall be constructed of high-impact polystyrene. The access for wiring shall be external.The motor disconnect shall be internal and of the plug-in type. The motor shall be mounted on vibration isolators.The fan wheel shall be of the forward-curved centrifugal type and dynamically balanced. The fan shall have a rocker switch with 3 cfm settings located internally. For the SP-A50-90-VG the settings are 50, 70, and 90 cfm. For the SP-A90-130-VG the settings are 90, 110, and 130 cfm.The fan will come preset at 70 cfm for the SP-A50-90-VG and 110 cfm for the SP-A90-130-VG. Upon installation,the switch shall be selected to the desired CFM.All fans shall bear the AMCA Certified Ratings program AMCA Sound and Air Performance seal and shall be UUcUL Listed. Ceiling or wall mount fans shall be model SP as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin. Complete specifications, in Construction Specifications Institute (CSI)format, are available on greenheck.com. f 29 r Model Specifications • - in Air �' z; Model SP-8O(L)-VG, SP-110(L)-VG - Ceiling mounted exhaust fans shall be of the centrifugal direct drive type with an EC motor and overload 101001 protection. The fan housing shall be constructed of ''- galvanized steel and have a low profile housing. The �, outlet duct collar shall have an aluminum backdraft damper. The fan shall be capable of built-in two-speed operation with a time delay. The access for wiring shall be external. The motor disconnect shall be internal and of the plug-in type. The fan wheel shall be of the forward-curved centrifugal Models SP-A5O thru A155O type and dynamically balanced. All fans shall bear the Ceiling mounted exhaust fans shall be of the centrifugal AMCA Certified Ratings program AMCA Sound and Air direct drive type.The fan housing shall be constructed Performance Seal and shall be UL/cUL Listed. of heavy-gauge galvanized steel.The housing interior shall be lined with 0.5 inch (13 mm)acoustical insulation. Models SP-B50, B70, B80, B90, B11O, B150, The outlet duct collar shall include a polypropylene and B200 backdraft damper on SP-A50-SP-A90 and a spring loaded aluminum backdraft damper on SP-A110 and Ceiling mounted exhaust fans shall be of the centrifugal larger.Outlet shall be adaptable for horizontal or vertical direct drive type.The fan housing shall be constructed discharge.The designer grille for sizes SP-A50 through of galvanized steel. The polypropylene duct collar shall SP-A390 shall be constructed of high-impact polystyrene be 6 inches(152 mm) in diameter and shall include and for sizes SP-A410 through SP-A1550,the grille a backdraft damper.The designer grille shall be shall be constructed of aluminum. Grilles shall be constructed of non-yellowing high-impact polystyrene non-yellowing. and attached to the housing with hidden attachment screws. The access for wiring shall be internal.The The access for wiring shall be external.The motor motor disconnect shall be internal and of the disconnect shall be internal and of the plug-in type. plug-in type. The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal The motor shall be mounted on vibration isolators. type and dynamically balanced. All fans shall bear the The fan wheel shall be of the forward-curved AMCA Certified Ratings program AMCA Sound and Air centrifugal type, constructed of calcium carbonate filled Performance seal and shall be UUcUL Listed. Ceiling polypropylene and dynamically balanced.All fans shall fans shall be model SP as manufactured by Greenheck bear the AMCA Certified Ratings program AMCA Sound Fan Corporation, Schofield, Wisconsin. and Air Performance Seal and shall be UUcUL Listed. Model SP-A fans with 50 hertz motors are not AMCA certified. Ceiling fans shall be model SP-B50, B70, B80, B90, B110, B150 or B200 as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin. Model SP-B fans with 50 hertz motors are not AMCA certified. 30 mmW:. Model Specifications ., ,�. ;'�. Model SP-050 Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of galvanized steel. The polypropylene duct collar shall be a sleeve for ease of connection to 3-inch (76 mm) and 4-inch (102 mm)round ductwork and shall include a backdraft damper. The grille shall be constructed of non-yellowing high-impact polystyrene and attached to the housing with torsion springs. The wheels shall be constructed of high-strength polymer.The access for wiring shall be easily accessible internally. The motor disconnect shall be internal and of the plug-in type. All fans shall bear the Models CSP-A110 thru A3600 AMCA Certified Ratings program AMCA Sound and Air Performance seal. Model SP-050 shall be UL Listed. Duct mounted exhaust, supply or return air fans shall Fans shall be model SP-050 as supplied by Greenheck be of the centrifugal direct drive type. The fan housing Fan Corporation, Schofield, Wisconsin. shall be constructed of heavy-gauge galvanized steel. Model SP-C fans with 50 hertz motors are not AMCA certified. The housing interior shall be lined with 0.5 inch (13 mm) acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper and shall be adaptable for horizontal or vertical discharge. The access for wiring shall be external. The motor disconnect shall be issijou ''`. p internal and of the g-lu m type. e. P The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal type and dynamically balanced.All fans shall bear the AMCA Certified Ratings program AMCA Model SP-L50 and SP-L80 Air Performance Seal and shall be UUcUL Listed. Wall or ceiling mounted exhaust fans shall be of the Ceiling fans shall be model CSP as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin. centrifugal direct drive type.The fan housing shall be constructed of galvanized steel. The galvanized duct Model CSP-A fans with 50 hertz motors are not AMCA certified. collar shall be sized to fit a 4-inch diameter duct and Models CSP-B110, B150 and B200 shall include a backdraft damper. The grille shall be constructed of non-yellowing high-impact polystyrene Duct mounted exhaust, supply or return air fans and attached to the housing with hidden attachment shall be of the centrifugal direct drive type.The fan screws. The access for wiring shall be internal.The housing shall be constructed of galvanized steel. The motor disconnect shall be internal and of the plug-in polypropylene duct collar shall be 6 inch (152 mm) in type. diameter to accept 6-inch (152 mm) round ductwork The fan wheel shall be of the forward curved and shall include a backdraft damper. The access for centrifugal type, constructed of calcium carbonate filled wiring shall be internal. The motor disconnect shall be polypropylene and dynamically balanced.All fans shall internal and of the plug-in type. bear the AMCA Certified Ratings program AMCA Sound The motor shall be mounted on vibration isolators. and Air Performance Seal, shall be UUcUL Listed and The fan wheel shall be of the forward-curved shall be Energy Star 4.0 qualified. Wall or ceiling mount centrifugal type, constructed of calcium carbonate fans shall be model SP-L50 or L80 as manufactured by filled polypropylene and dynamically balanced.All Greenheck Fan Corporation, Schofield, Wisconsin. fans shall bear the AMCA Certified Ratings program AMCA Air Performance Seal and shall be UUcUL Listed. Ceiling fans shall be model CSP-B110, B150 or B200 as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin. Model CSP-B fans with 50 hertz motors are not AMCA certified. 31 Design and Selection Support � r i .+ , Enjoy Greenheck's extraordinary service, before, during and after the sale. 4 , Greenheck offers added value to our wide selection of top performing, energy-efficient - _ products by providing several unique Greenheck service programs. --'"' Our Quick Delivery Program ensures shipment of our in-stock products _-_ Di within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3-5-10-15 or 25-day production cycles, depending upon their complexity. Ilif Greenheck's free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products -NIP and ongoing corporate commitment to sustainability can help you qualify Greenheck for LEED credits. - sr: GREEN t Our 3D service allows you to download, at no charge, easy-to-use AutoDeske Revit®3D drawings for many of our ventilation products. €, Find out more about these special Greenheck services at greenheck.com 0 t y t in ill sa t fi ' Building Value in Air r 11;- Greenheck delivers . .. top quality,innovative air- ' - And building owners and • to mechanical engineers by related equipment.We offer occupants value the energy helping them solve virtually extra value to contractors efficiency,low maintenance any air quality challenges by providing easy-to-install, and quiet dependable operation '' '--`i their clients face with a competitively priced,reliable they experience long after the comprehensive selection of products that arrive on time. construction project ends. Our Commitment (,,�e� LbINS ic o As a result of our commitment to continuous improvement,Greenheck reserves the right to change N \ / n specifications without notice. Product warranties can be found online at Greenheck.com,either on the specific product page or McMBE5` , siog in the literature section of the website at Greenheck.com/Resources/Library/Literature. Prepared to Support Green Building Efforts , [74 GREENHECK - Building Value in Air. 00.r8U.1013 R152-2019 SP P.O. Box 410•Schofield, WI54476-0410•Phone(715)359-6171 •greenheck.corn Copyright 02019reenheck Fan Corp. OPERATING MAINTENANCE REZtIOR® INSTRUCTIONS INSTRUCTIONS Rezmor LLC O'Fallon,MO USA 63368-Tel.:1800 695-1901 The heater must be properly installed before it is used. The heater motor is permanently lubricated. www.ReznorHVAC.com 02014 Reznor,LLC.All rights reserved.All other trademarks are the property of their respective organizations. HEATER OPERATION Occasional cleaning of the inlet grille will prevent clogging. Use a vacuum with a brush attachment. INSTRUCTIONS Start an Cleaning should be done while the heater is disconnected from EGEB Model(10.1 kW to 20 kW) On a call for heat from either the remote thermostat or the unit the main service panel.Wait until the housing and heating elements cool before performing maintenance. mounted thermostat the elements and fan will be energized. © WARNING A When the thermostat is satisfied the elements will be deenergized. Anny o er servicing should be performed by a qualified te• The fan will continue to mn until the residual heat is removed When using electrical appliances,basic precautions should always be from the heater.Then the fan will stop. taken to reduce the risk of fire,electrical shock and injury,including the following, Automatic Reset Thermal High Limit Read carefully these instructions before installation,operation of the heater.Failure to adhere to the instructions could result in fire,electric The heater has an automatic reset thermal high limit that will deener- shock serious personal injury,and death or property damage.Review itsgize the heating elements if the interior temperatures of heater exceed frequently for continuing safe operation and instruction of future its setting.The limit will aumlling. lly reset when the heater interior users,if necessary. temperatures fall below its setting. IMPORTANT INSTRUCTIONS - Read all instructions before installing or using this heater. - This heater is hot when in use.To avoid bums,do not let bare skin touch hot surfaces. Keep combustible materials, like furniture, pillows, bedding, papers, clothes, and curtains at least 36 in. (915 om)from the front of the heater and away from the sides and rear. - Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended. - Do not operate any heater after it malfunctions.Disconnect power at service panel and have heater inspected by a reputable electrician before reusing. - To disconnect heater, turn off power to heater circuit at main disconnect panel. - Do not use outdoors. - Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electrical shock or fire,or damage the heater. - To prevent a possible fire,do not block air intakes or exhaust in any way whatsoever. - A heater has hot and arcing or sparking parts inside.Do not use it in areas where gasoline,paint or flammable liquids are used or stored. - Use this heater only as described in this manual.Any other use nut recommended by the manufacturer may cause fire,electrical shock, or injury. - The thermostat should not be considered an infallible device in cases where maintaining a temperature is considered critical.In these particular cases,it is imperative to add a monitoring system to avoid the consequences of a thermostat failure. - This heater is not approved for use in corrosive atmospheres,wet or very humid locations such as marine,green house or chemical storage areas. SAVE THESE INSTRUCTIONS 1Ns263-201001-07 111, REZ INSTRUCTIONS TL DOS rLLC UIIA ON INSTRUCTIONS O'Fallon,MO USA 63368-Tel.:1 800 695-1901 www.ReciaorHVAC.com Laappareil dolt etre installs correctement avant de]'utiliser. Le moteur de Iappareil de chauffage est lubrifie de maniere C2014 Revlon,LLC.All rights reserved.All other trademarks are the property permanents. of their respective organizations. FONCTIONNEMENT DE L'APPAREIL la Nettoyer grille d'entree Wait de temps mps a autre pour sviter INSTRUCTIONS Y Mise en marche 1'encrassement.Utiliser un aspirateur muni d'une brosse. EGEB Model(10.1 kW to 20 kW) Des que le thermostat mural ou le thermostat integre a Peppered Le nettoyage dolt etre fait apres avoir coupe I'alimentation A envoi uric demands Jr chauffage,les elements commencent a electrique au hennas d'alimentation principal.Attendre chauffer et le ventilateur dematre. que le bother et les elements de Pappareil aient refroidi AVERTISSEMENT avant de proceder a 1'entretien. Lorsque la te.uphature desires est atteinte an thermostat,les Lors de I'utilisation d'appareils 0lectriques,it est important de respecter les elements cessent de chauffec Un technicien qualifie peat accomplir tout autre service. regles de securite de base,notemment les consigns suivantes,pour reduire les risques d'incendie,de choc electrique el de blessure. Le ventilateur continue de fonctionnerjusqu'a cc que la chaleur residuelle soil evacuee de lappareil.Le ventilateur s'eteint ensuite Lire attentivement ces instructions avant de proceder a Piostallation ou de lui-meme. I'utilisation de eel appareil.Ne pas respecter ces instructions peut entrainer un incendie,une electrocution,des blessures graves,la mortou des degats materiels. Protection thermiuue a reencienchement Consultez-les regulierement pour assurer on bon fonctionnement securitaire et renseigner les tutus utilisateurs,tress echeant. automatique INSTRUCTIONSL'appareil est muni d'une protection thermique a reenclenchement IMPORTANTES automatique qui stein les Elements chauffants lorsque la temperature interne de Pappareil depasse sa veleur de reglage. - Lire attentivement toutes les instructions avant d'installer ou d'utiliser cot Ce dispositif remet Pappareil de chauffage en marche des que la apparel temperature interne a baisse sous se valour de reglage. - La temperature de surface du bother de Pappareil peat etre elevee lorsqu'il fonctionne.Pour prevenir les brolures,eviter de toucher les surfaces chaudes du boitier avec la peas.Gander les produits combustibles lets que mobilicrs, coussins,literies,joumaux,vetements el rideaux a une distance d'au moms 36 po(915 tom)du devant de Pappareil et eloignes de farriers et des cotes. - Toujours prendre d'extremes precautions lorsqu'un appareil de chauffage est utilise a proximite d'enfants on de personnes handicapees,ou lorsqu'il est laisse en fonction sans surveillance. - Ne pas utiliser eel appereil de chauffage apres un mauvais fonctionnemcnt. Couper Palimentation electrique au panneau d'alimentation et faire inspector Pepperell par un technicicn qualifid avant de reutiliser. - Pour debrancher l appareil,couper]'alimentation electrique sur le panneau d'alimentation principal. - Ne pas utiliser a 1'exterieur. - Ne pas inserer de corps strangers a I'interieur des bouches de ventilation ou de sorties d'air de Pappareil,sow risque de provoquer un incendie on un court-circuit,ou d'endommager l'appareil. - Pour prevenir les risques d'incendie,no pas bloquer les entrees et les sorties d'air de lappareil. - Certaines composantes de Pepperell peuvent etre chaudes et produire des arcs electriques et des etincelles.Ne pas utiliser dans un lieu oil l'on utilise ou entrepose de]'essence,de la peinture ou tout autre liquide inflammable. - Utiliser lappareil conformement aux instructions de cc manuel. Toute utilisation autre quo cellos que recommandent le fabricant representc un danger d'incendie,de choc electrique ou de blcssures. - Le thermostat ne doit pas etre considdre comme un dispositif infailiible dans les ces oil le maintren d'une temperature est juge critique.Dans cos cas particuliers,it est imperatif d'ajouter un systeme de surveillance afin d'eviter les consequences d'une defaillance du thermostat. - Cel appareiln'e pas etc approuvepourune utilisation dens des environnements cortosifs,mollilles ou tres humides tell que les milieux matins,les seises et les sires d'entreposage de produits chimiques. CONSERVER CES INSTRUCTIONS INS263-201001-07