Loading...
Specifications OFFICE COPY OFFICE COPY Mac-21)-2-1- 00011 N 202►- 0 0 0 12 M>rG20?,1 -00015 sT0 y URAL CALCULATIONS 00 CULLUMBER ENGINEERING WW For Tigard Business Park: Tenant RECEIVED JAN 6 2021 Improvement CITY OF TIGARD BUILDING DIVISION Client: PM Design Group Project Address: SW Garden Place, Tigard,OR 97223 Homeowner: - Project Number: CM110920 Purpose: Structural Engineering for T.I. Date: 111/11/2020 Engineer: D. Goretoy, E.I. FOR: Wesley Cullumber, P.E. The design calculations contained herein have been prepared by or under the direction of the following Registered Civil Engineer: WESEEY CULLUM8ER No. 80675 e„ 03-A I-2 I Wesley Cullumber, PE CullumberEng.com wcullumber@CullumberEng.com 916-251-9798 STRUCTURAL CALCULATIONS Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR97223 AND DESIGN If` Project No.: CM110920 Table of Contents 1. DESIGN CRITERIA 2 PROJECT APPROACH 2 DESIGN VALUES 2 CODE REFERENCES 3 2. SEISMIC ANALYSIS 4 3. WIND ANALYSIS 5 4. STRUCTURAL CALCULATIONS 6 ADDRESS 6930 DestinyDrive Suite#300,Rocklin,CA 95677 PHONE:916-251-9798 WEB:www.CullumberEng.com II g Page 1 of 13 STRUCTURAL CALCULATIONS Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 ND D ESI G 1' Project No.: CM110920 1. DESIGN CRITERIA PROJECT APPROACH Typical design approach for gravity and lateral analysis. Seismic loading applied for lateral analysis. Gravity loading applied as specified in the calculations. DESIGN VALUES 1. CRITERIA Risk Category =II 2. GRAVITY LOADS Space heater Weight (DL) =90 lb 3. SEISMIC LOADS MCER ground motion(period=0.2s) Ss =0.863g MCER ground motion(period=1.0s) S1 =0.395g Design Spectral Acc.for Short Periods SDS =0.691g Design Spectral Acc.for 1-sec. Periods SD1 =0.525g Response Modification Factor R =2.5 Soil Site Class = D Seismic Design Category = D Basic Seismic Force Resisting System: design for non-structural components 4. WIND LOADS(not in scope) Ultimate Wind Speed(3-Second Gust) =96 mph Basic Wind Speed,Vasd =77 mph Wind Exposure =C Topographic Factor Kzt =1.0 5. GEOTECHNICAL(not in scope) ADDRESS:6930 Destiny Drive Suite t#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 2 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR97223 AND DESIGN INL Project No.: CM110920 CODE REFERENCES ASCE 7-16 Minimum Design Loads for Buildings and Other Structures ACI 318-14 Building Code Requirements for Structural Concrete and Commentary CBC 2019 California Building Code 2019 AISC Steel Construction Manual 14th Edition ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 3 of 13 STRUCTURAL CALCULATIONS „0,..)frithoNkeN. Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 %i19U D CC Project No.: CM110920 f.- 2. SEISMIC ANALYSIS CTC Hazards by Location Search Information v Address: 11952 SW Garden Pt.Tigard.OR 97223.USA 1r,,,,rr,uver tar 193 ft Coordinates: 45.433863.-1227630817 i"k'i 0land Mdlsbo+oU ;CA Gresham Elevation: 193 ft Beave on (771 Mt. Tirnestamp: 2020-11-10T23.29:34A282 Nation Hazard Type: Seismic Reference ASCE7-16 GO gle Map data r=7020 Google Document: Risk Category: II Site Class: O-dc`.ault Basic Parameters Name Value Description Ss 0,863 MCER ground motion(period=0,2s) Si 0,395 MCER ground motion(period=l,Os) SPAS 1.036 Site-modified spectral acceleration value SM1 *null Site-modified spectral acceleration value Sos 0.691 Numeric seismic design value at 0.2s SA Sp1 -nul Numenc seismic design value at 1.0s SA See Section 11.4.8 vAdditional Information Name Value Description SDC 'nu11 Seismic design category F, 1.2 Site amplification factor at 0.2s Fv *nul Site amplification factor at 1.0S C,RS 0.887 Coefficient of risk(02s) CR1 0.867 Coefficient of risk(1.0s) • PGA 0.393 MCEO peak ground acceleration FpGA 1,207 Site amplification factor at PGA PGAM 0.474 Site modified peak ground acceleration ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 4 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 DESIGN INC ProjectNo.: CM110920 3. WIND ANALYSIS OTCHazards by Location Search Information • © _ , Address: 11952 SW Garden PI,Tigard,OR 97223.USA Vanrnilggt ty ;...�,-+`fi' t7t) 193 ft Coordinates: 45A33863.•1227630817 Wini I G land flrll•,hrrnr o Ki Gresham Elevation: 193 ft Heave on ID Mt. Timestemp: 2020-11-10T2329:02.955Z Nation Hazard Type: Wind Go gle ry Map data r2020 Google ASCE 7-16 ASCE 7.10 ASCE 7.05 MRI 10-Year 68 mph MRI 10-Year 72 mph ASCE 7-05 Wind Speed 85 mph MRI 25-Year 72 mph MRI 25-Year 79 mph MRI 50-Year 77 mph MRI 50-Year 85 mph MRI 100-Year 82 mph MRI 100-Year 91 mph Risk Category I 90 mph Risk Category I 100 mph Risk Category II 96 mph Risk Category II 110 mph Risk Category III 103 mph Risk Category IIl-IV 115 mph Risk Category IV 107 mph The results indicated here DO NOT relied arty state or local amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard bads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer.Per ASCE 7,islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area-in some cases,this website wil extrapolate past the last wind speed contour and therefore,provide a wind speed that is slightly higher.NOTE For queries near wind-borne debris region boundaries.the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. Mountainous terrain,gorges,ocean promontories.and special wind regions shall be examined for unusual wind conditions. Whie the information presented on this website is believed to be correct.ATC and its sponsors and contributors assume no responsibility or liablity for its accuracy.The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy.suitability and applicablity by engineers or other licensed professionals.ATC does not intend that the use of this information replace the sound judgment of such competent professionals,having experience and knowledge in the field of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website.Users of the information from this website assume all liablity arising from such use.Use of the output of }alit waheltA AM!nM Im.,l,arwnutl MI Ma,newaminn k IINIM M,o M,eac roennnealla Inr M1aninn nestle onnra,nil Mn intonVOtinINI few rhn • ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 5 of 13 , . STRUCTURAL CALCULATIONS Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DESIGN INC- Project No.: CM110920 4. STRUCTURAL CALCULATIONS I _ _ I -----‘'-- P .1 11 SPACE L.....,____________I HEATER LOCATION 1 I : • • • • ---...„.., CI , 11 i • • .._._ ,.; kl ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 6 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DESIGN INC Project No.: CM110920 e TIP Description: (Seismic Demand on Non-Structural Components Date: I11/11/2070 (ASCE 7-10&16, 13.3) Lateral Force Procedure Occupancy Importance Ip 1.0 Design Spectral Accele Sos= 0.691 g Design Spectral Accele SDI= 0.525 g Component Amplificat ap Component Response RP FP= [0.4apSosWp*(1+2z/h)]/(Rp/lp) Component Weight Horizontal Shear Vertical Shear Remarks p lb ap R p Fp Max Min. Design Fp Fv Design Fv Space Heater 90 1 2.5 0.33 1.11 0.21 30 0.14 12 Heater with Bracket system by manuf. Equations: Horizontal Shear Design FP= (1.2aPSosWP)/(RA) Fp is not required to be taken greater than FP= 1.6SoslpWp Fp shall not be taken less than, Fp= 0.3Sosl,Wp Vertical Shear Fv= 0.2SDSWp ADDRESS:6930 Destiny Drive Suite##300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 7 of 13 STRUCTURAL CALCULATIONS Project Name: _Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 E r r ?--,. Project No.: CM110920 d-6" min —♦ T C dc=12" a34 min '%. 6" jf min 1. hd # Fv=1212# WOOD BLOCKING Fv ATTACHMENTS Load Combo LC=DL+0.7Fv=99# At wood blocking Assume dc=18"stead 1/2"dia thru bolt wi 2"dia.washers If 4x12 DF#2. Fc_perp=625psi Mc=O=T(d) . LC(dc) Washer area A=rrrA2=3.14 inA2 Allowed Ta=Fc'A=1,960#>T OKI T=LC(dc)I d=99'18"/6"=297# Vertical Shear Z=510#> LC OK! T-C Wood blocking to studs If Simpson A34 at lop&bot Z=395# Z>T&C OK! At Concrete Wall If 1/2"dia. HMI KWIK Bolt 3 carbon Steel Embedment length Le=2.25"min, Z=1,865">LC OK! Ta=1,235#>T OK! ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 8 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 1 .1 DESIG" ProjectNo.: CM110920 Mechanical 4nchera.o Syuto !e KWIK Bolt 3 Expansion Anchor 3.3.6 Table 6•Carbon Steel KWIK Bolt 3 Allowable Loads in Normal-Weight Concrete' AnchorEmbedmentf,-2000 psi 113 8 MPa) f',.-3000 psi(20 7 MPa) f',-4000 psi(27.6 MPa) /.•6000 psi(41.4 MPa) Pa) Depth Tension Shear Tension Shear Tension Shear Tension Shear in. Oran) n. (mna b 91M lb (uN) lb 4kM b 91141 b (kM lb 9(N) lb MN) lb (kN) 1 //8 Rgf 300 365 430 550 (1.3) (1.6) (1.9) (2.4) 1/4 635 530 715 530 800 530 530 46.4) 2 ls1) (2.8) RA) (3.2) (2.4) (3.6) R.4) 845 (2.4) 3 n61 755 795 840 (3.8) (3.4) (3.5) (3.7) 730 1135 910 1275 1095 1090 1.5/8 (41) (3.2) 15.0) (4.0) (5-7) (4.9) 0.8) 3/8 24 n 164) 1260 1555 1850 1315 2060 1315 (9.51 (5.6) 1315 16.9) 1315 18.2) (5.6) (9.2) (5,8) 1580 (5.8) 1770 (5 8) 1965 2150 3-1/2 (891 (7.0) (7.9) (8.7) (9 6) . 1235 1665 1430 2300 1620 2405 1975 2.174 (571 (5.5) (8.3) MA) 110.2) (7.2) (10.7) (8.8) 112 31/2 (89) 1930 2185 2440 3240 2415 (12.71 (8.6) 2415 (9.7) 2415 (10.9) 2415 (14.41 (10.7) 4•8/4 (121) 2135 (10.7) 2355 (10.7) 2575 (10.7) 3620 (9.5) (10.5) (11.5) (16.1) 1970 2750 2085 3410 2210 3785 2830 2.3/4 (701 (8.51 (12.2) (9.7) (15.2) (9.8) (16.8) 112.6) SA 2660 3020 3385 4770 3910 115.9) 4 (1021 (11.8) 3910 (13.4) 3910 (15.11 3910 R1.2) (17.4) 5.1/2 (140) 3285 (17.4) 3695 (17.4) 4100 (17.4) 5325 (14.6) (16.4) 118.21 (23-7) 2120 4090 2425 4900 2730 6310 3785 6310 3•1/4 (83) (9.4) (18.2) (10.6) (21.8) 112.1) (23.6) 116.81 (23.61 4 3/4 1121) 3240 4260 5285 6155 (101) (14.4) 5340 (18.9) 5340 (23.51 5495 (27.4) 6225 4535 (23.8) 5860 (23.8) 7185 (24.4) 7005 (27.71 6.1/2 (1651 (20.2) (26.1) 132) (31.2) 3330 7070 4050 7600 4870 8140 5070 4.1/2 (114) (14.8) (31.4) (18.0) (33.8) R0.8) (36.21 (22.6) 1 4930 6000 7070 8400 9200 (25.4) 6 1152) R1.9) 9200 (26.7) 9200 (31.4) 9200 (37.4) (40.9) 9 (229) 6670 (40.9) 7670 (40.9) 8670 (40.9) 10670 (29.71 (34.11 138.6) (47.5) I lhkarned.Me bad vases to 0trv.,r.iu...It's'rcr'.)tn,.rrvl,,,,u,h!rl l*can be calculated by Wear uNnpolate°. I .MC 6i411-400479.KO' Mwv as hhr.cem en aapa n11.90P479-5000 I kill,)Ca sfal Cap I.69U.M3'4i5a 1 MMMha4.ca 1 AMw iasuonng Tecnney God.2011 N9 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 9 of 13 STRUCTURAL CAL Project Name: Tigard Business Parkrk::TenTenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 Project No.: CM110920 Table 126 BOLTS: Reference Lateral Design Values.Z,for Single Shear (two member)Connections'= for sawn lumber Or SCL main member w;^,h 1:4"ASTM A 36 steel so-Jc plate Thickness Zif 11, 1 0E� dm Z. V0. - p2ID i 0 2 2 Z m O N p 'o N f W f N LL < LL 4 b Mf C n �s `At O m v S c$ � ! 0 40 Slit Re 8a Q $ 5; a Sw o 3 kn as 0e G7 +! 8 0o c0o C., x 0= 0rn lDo $ (2wrPi38: t7z t,., t. D Z. Z1 Zu Z1 Z. Za 2. Z1 Za Z1 Za Z1 Zu 21 Za Z1 Za Zt Zn Z1 In. in. in. lbs. lbs_ lbs. lbs. lbs. lbs. lbs lbs. lbs lbs lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. 1/2 730 420 620 350 580 310 580 310 550 290 520 280 510 270 470 240 460 240 450 230 518 910 480 780 400 730 360 720 360 690 340 650 320 640 320 590 290 580 280 560 270 1-112 1/4 3+4 1690 550 940 450 870 420 860 410 820 390 780 360 770 360 710 320 690 320 680 310 718 1270 600 1090 510 1020 470 1010 450 960 430 910 410 900 400 820 370 810 360 790 350 1 1460 660 1250 550 1170 510 1150 500 1100 480 1040 450 1030 450 940 400 930 400 900 390 112 810 460 690 370 640 340 630 330 600 310 570 290 560 280 510 250 500 250 490 240 5/8 1020 520 870 430 800 390 790 38D 750 360 710 340 700 330 640 300 630 290 610 280 1-34 1/4 3/4 1220 590 1040 480 960 440 950 430 900 410 860 380 840 370 770 330 760 330 730 320 7/8 1420 650 1210 540 1130 490 1110 480 1050 450 1000 420 980 420 890 360 880 370 850 360 1 1630 710 1380 580 1290 540 1270 520 1200 500 1140 470 1120 480 1020 410 1000 410 980 400 112 930 600 860 470 830 410 820 400 780 380 740 350 720 340 650 300 640 290 620 280 5/8 1370 670 1150 530 1050 470 1040 470 980 430 920 400 910 390 810 340 800 330 770 320 2 1:2 1.4 3/4 1640 750 1370 590 1270 530 1250 520 1160 490 1110 450 1090 440 980 380 960 370 930 360 7/8 1910 820 1600 650 1480 590 1450 570 1370 530 129D 490 1270 480 1140 420 1120 410 1080 400 1 2190 880 1830 700 1690 640 1660 620 1570 580 1480 540 1450 530 1300 460 1280 450 1240 440 1.'2 930 620 86D 550 830 510 820 51D 800 480 770 450 770 430 720 370 720 360 710 350 5r8 13{0 eerl 1250 COO 1210 610 1200 600 1160 550 1130 500 1120 490 1060 420 1050 410 102D 400 3-1;2 14 3 4 1900 990 1740 760 1670 680 1660 660 1580 610 1480 560 1450 540 1290 460 1260 450 122D 440 7/8 2530 1070 2170 840 1990 740 1950 710 1840 660 1720 610 1690 590 1510 510 1480 500 1430 470 1 2980 1150 2480 890 2270 800 2230 770 2100 730 1970 660 1930 650 1720 560 1690 540 1630 530 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 WEB:www.CullumberEng.com Page 10 of 13 STRUCTURAL CALCULATIONS • itle Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR97223 AND r-d = Project No.: CM110920 CEILING OR ROOF C' MIN. �, FRAMING LINO MIN NE . NI SPACE NEATER BRACKET SUPPOR PER MANUP. REQUIREMENT aftWALL MOUNTED BRACKET MOUNTING KIT BRACKET BY MANUP. ATTACINMENT PER DETAILS BELOW I �-- EXISTING IE)WALL SPACE NEATER BY OTNERS 1- 6 1._ 6' MP;. MIN ---,i 510E VIEW FRONT VIEW ADDRESS:6930 Destiny Drive Suite 14300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 11 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR 97223 AND DESIGN INC Project No.: CM110920 12)METAL STUD••Ar 3625;62-43 TO(E)WALL TOP TRACK W/(3)01O TEES 45°MAX ' ', PROVIDE DIAG.BRACE IF( )PARTITION 15 NOT SECURED AT TOP 1.4- NEW BLKG INSTALL NEW BRACKET BACK PLATE TO SOLID . n`a IE)METAL.STUD IE)METAL STUD BLKG SURFACE.REMOVE WALL . WALL GYPSUM BOARD AS >-.... _._--_. ..... , I ( �� »NEEDED I jl 12)Y2'm TnRU BOLTS ___ MINIMUM THRU-BOLT MIN. �w- �'__ - 1, SPACING `I� PROVIDE SOUO PLY BLKG I AS NEEDED (3) 12 WOOD OR tii I. ® TEE SCREWS TO BLKG ENDS NEW 4%I2 Dr,2 HEATER SUPPORT IY2 BIKE;SEWN(E) HEATER SUPPORT BRACKET BY MANUF, ANN. I I) II WALL STUDS BRACEET I SIMPSON A34 AT TH3 SECTION Aq Wf TEK SCREWS TO I ' METAL STUD ATTACHMENT TO METAL STUD WALL 2 12)METAL STUD BRACE 3625162.43 TO(E)WALL TOP TRACK W1131#10 TEES 45•MAX cI PROVIDE DIAG BRACE IF IL)PARTITION IS NO7 SECURED AT TOP NEW BLKG INSTALL NEW BRACKET If1 WOOD STUD BACK PLATE TO SOLID • (E)WOOD STUD Yfat.l. BLKG SURFACE.REMOVE WALL _-.- I GYPSUM BOARD AS NEEDED I*. (2)YZ•0 THRU BOLTSIf i _• �T MINIMUM TnRULBOLT AMN, I SPACING Et..' m (N) i 6D TO BLKG ENDS AT TOP.MAD. ®i AND BOTTOM NEW 4%1 2 DE02 HEATER SUPPORT HEATER SUPPORT IY2 NAG BTWN(E) BRACKET BRACKET BY MANUf. MIN. WALL STUDS SIMPSON A34 AT TO r_ ATTACHMENT TO WOOD STUD WALL I 3 ADDRESS:6930 Destiny Drive Suite t(300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 12 of 13 STRUCTURAL CALCULATIONS • Project Name: Tigard Business Park:Tenant Improvement CULLUMBER ENGINEERING Location: SW Garden Place,Tigard,OR97223 it'ji� 4IL3iiyl°aj` Project No.: CM110920 IYi (E)CONC.WALL MINIMUM THRU.BOLT MIN. SPACING (2)Y21O CARBON STEEL I HILT! BOLT 3 W/ did °Yp'EMBEDMENT HEATER SUPPORT IYz • BRACKET 5Y MANUr. MIN. ATTACHMENT TO CONCRETE WALL 4 ADDRESS:6930 Destiny Drive Suite#300,Rocklin,CA 95677 I PHONE:916-251-9798 I WEB:www.CullumberEng.com Page 13 of 13 t Centrifugal Ceiling Exhaust and Inline Cabinet Fans Models SP and CSP / , . it. /Ir . OJ C r ,; 0 vim; - Z fi D 4c90,11 0 a� r '; 10_0 `Mlli Z D flGREENHECK 70 Building Value in Air. February 2019 rF Models SP and CSP H, • Ceiling and Cabinet Fans Great things come in small packages, as do our SP ceiling exhaust fan and CSP inline cabinet fan models. Be assured when you buy any Greenheck product, it is a quality product at a competitive price. Plus, we guarantee our SP and CSP fans with a three-year warranty. We are your market leader for the most comprehensive ceiling and cabinet fan line in the market. Typical Installations Benefits • Multifamily housing • Industry leading sound levels • Hotels • Compact size • Hospitals • Wide range of performance • Schools • Available with EC motors for higher efficiency • Bathrooms and more controllability • Helps maintain acceptable Indoor Air Quality,,,x „§ • Storage rooms Table of Contents Standard Construction Features 4-5 Model SP-L 15 Power Ratings and Certifications 6 Model CSP-B 15 Certifications 6 Model CSP-A 16-17 Van-Green® Motors and Controls 7 Model SP (50 cycle) 18 Sound and Fan Selection 8 Model CSP (50 cycle) 19 ENERGY STAR®and Codes and Standards . . . .9-15 Accessories 20-23 Model Number Code 9 Electrical Accessories 24-25 Model SP-VG 10 Discharge Accessories 26-27 Model SP-A-VG 11 Pressure Drop 27 Model SP-A 12-13 Specifications Vari-Green 28 Model SP-B and SP-C 14 Model Specifications 29-31 2 ti ' Models SP and CSP o._ �. ,• Ceiling and Cabinet Fans ...in. Value in Art'•t• Model Comparison Location Mounting Airflow Application �ype Impeller Type Performance C 0 F0. R Model jE m Eo d ' •. cN QiOo ca � ` a a2 0 a ° y ° ° m e ° °' m2V a Vv £ 9 E £ ° ° d m W a 1? a e . 3 f- ff m y E� E =a '° o o a e _ t a ° c e m a rn y m P x m E a 12 c o 2 8 A = 3 u 6 m a a 8 u fii t`s rn 'x 'x m o o E. F H f n. SP V V V V V V V V 1,600 1 CSP V V V V V V ✓ 3,800 1 (011.°5tt- . — _. __ Jr .,... lit ��4.' � 2, I. SP fans are designed for ceiling mounted exhaust applications. CSP fans are designed for inline supply or exhaust applications. Model Level of Description Profile Sound Air Volume UL Listing Construction min.height min.sones max.cfm Premium Plus Fan: 7 inches 110 cfm UUcUL Listed for above bathtub/ SP VG Highest performing energy (178 mm) <0.3 (187 m3/hr) shower with GFCI branch protected efficient fan circuit(sizes 110 and 80 only) Premium Constant CFM g inches 130 cfm UUcUL Listed for above bathtub/ SP A-VG Ceiling Fan: (229 mm) <0.3 (220 m'/hr) shower with GFCI branch protected 3 speed cfm selection circuit Premium Ceiling Fan: UUcUL Listed for above bathtub/ Widest selection to meet sound 9 inches 1,600 cfm 3 <0.3 SP A requirements. Select sizes (229 mm) (2718 m'/hr) shower with GFCI branch protected u_ available with Vari-Green motor. circuit(Sizes A390 and smaller) cn 5 Deluxe Ceiling Fan: d Compact to fit most 7 inches 200 cfm UUcUL Listed for above bathtub/ c) SP B applications with quiet (178 mm) 0.8 (340 m3/hr) shower with GFCI branch protected operation circuit Low Profile Ceiling Fan: 35/e inches UUcUL Listed for above bathtub/ SP L Designed to fit in 2x4 wall (86 mm) 1.0 84 cfm shower with GFCI branch protected construction circuit. Economy Ceiling Fan: 35/e inches 50 cfm SP C Designed for light commercial (86 mm) 3.0 (85 m3/hr) UL Listed applications Premium Inline Fan: u, Widest selection and industry- 9 inches 3,775 cfm @ CSP A 0'8 (6414 m3/hr) UUcUL Listed leading low sound.Select sizes (229 mm) available with Vari-Green motor. 2 Deluxe Inline Fan: 7 inches 185 cfm CSP B Compact design to fit in small 1.5 (178 mm) (314 ms/hr) UUcUL Listed remote spaces All dimensions are in inches(millimeters) 3 Standard Construction Features a _-- 6 tttt {. ANC e ti\�.. +�. ..<-.�,- inAir' . Model SP-A and SP-A-VG Model SP-B eltikl , '''f. 1 0 0 - 2 8 3 6 O -_ 4 11 tiy/ 12 f 3 12 r „r•r• �. IC 14 '�-^ / 411•..e apt. 4 I) s .©7 Model SP-L O :.....„ 4-, 3 11 imicii Model SP-C `-744 1‘12 Model SP-VG 1 • -0, . -I,: 2 11 \ . -.:-.0. iir i \ 3 1.. ; 0. 10 12,/�/r J r 7 12 . 'C _ 11 4 Model CSP-A Model CSP-B s ©' 4C 0.iiiik / 7 ' 11 . 3 k.x> t 12 .r. 3 b.-. s ' 1 i 11 $ 10 10 13 '"'. 13 -_ 4 Standard Construction Featuresif . .1 r"T- K--,.'.. . .: , Value inAir. . �: Number and Description I Features for Each Model Specific SP-VG SP-A SP-B SP-C , SP-L CSP-A CSP-B Backdraft Durable plastic to reduce backdrafts 50-90 V V V V 1 Damper p Aluminum to reduce backdrafts ✓ 110-1550 V 50-90 Round-For quick and easy connections V 50-90-VG V V V 90-130-VG 2 Outlet Square-For quick and easy connections 110-1550 V Oval-Metal construction for increased fire V. _ resistance Removes quickly for maintenance/replacement ✓ V V V ✓ V. 3 Power Pack Includes conversion from horizontal to _ vertical discharge V V Vertical electrical access to eliminate V/ V Ceiling V if drilling holes 4 Electrical Access Horizontal electrical access Wall External electrical access to save installation time V V V 5 Electrical Eliminates drilling holes V V ✓ V ✓ V V _Knockouts (horizontal or vertical) Acoustic 6 Absorbs sound V V Insulation 7 Disconnect Servicing is quick and safe V V V ✓ ✓ V V 8 Electrical Large for easy wiring V V V V V V V _Junction Box 9 Grille Concealed attachment screws securely fasten V V V grille to housing for quiet,rattle free operation Mounting Adjustable for multiple installation conditions ✓ V. V V V V 10 Brackets Integral for quick installation V V Embossed galvanized steel for rigidity V V V ✓ V V V 11 Housing A low profile for height restricted areas V V V V V Motors are compatible for use with speed controls and have thermal overload protection 60 60 60 12 Motors Domestic&International cycle, V ✓ cycle, cycle, ✓ ✓ •50 cycle,220v or 240v 115v 115v 115v •60 cycle, 115v,208v,220v,230v,&277v options only only only (See CAPS or pg.6 for availability) 13 Access Panel Gain easy access to internal components once ✓ ✓ ✓ ✓ ✓ ✓ ✓ installed 14 CFM Speed User-controlled internal switch to set fan to 50-90-VG Selector operate at one of three speeds for desired airflow 90-130-VG Constant cfm motors capable of two speed ( 50 60 30 'N 70 30 Control with operation.Run at continuous low speed and 80(L) ! aG ,.�A -(p 70 is 45 99 154,4445 Van-Green switch to high speed on demand.ASHRAE 62.2, 110(L) 30 v 30 5 �>80 30 110 5 w Motor California Title 24 and Washington State Energy only ` CFM TIME i CFM TIME Code compliant. SP.L9(L).VGuaerad)uebblecontrols SP.H9(q.VG user-adjustable controls Exclusive Electrical access cover located on the housing exterior.This feature permits external wiring without removing Electrical Wiring the power assembly,saving installation time and cost.Available on models SP-A and CSP-A. Feature Available for applications requiring 700 cfm or greater. • {� Double-Wide Double-wide fans have two double-width forward-curved wheels, � I i I Fans which are housed in separate scrolls,and driven by a single motor. Available on models SP-A and CSP-A. Vertical Exhaust outlet duct installed in the optional vertical position. Discharge The power assembly must be rotated to match the duct adapter position. ill_ Available on SP-A and CSP-A models. 5 r► Power Ratings and Certifications r ;: 'H. , r, - in A�._40' " Available Motor Voltage and Cycle Ratings Available Motor Voltage and Cycle Ratings Power Rating V/Hz Power Rating V/Hz Models 115V/ 115V/ 220-240V/ 220-240V/ Van-Green Models115V/ 115V/ 220-240V/ 220-240V/ Van-Green (X) 60Hz 50Hz 50Hz 60Hz 277V Available(x) 60Hz 50Hz 50Hz 60Hz 27N Motor Option Option SP-A50 x x x x x SP-050' x SP-A70 x x x x x SP-80 x x SP-A90 x x x x x SP-80L x x SP-A110 x x x x x x SP-110 x x SP-A125 x x SP-110L x x SP-A130 x x x x x CSP-A110 x x x x SP-A190 x x x x CSP-A125 x x SP-A200 x CSP-A190 x x x x SP-A250 x CSP-A200 x SP-A290 x x x CSP-A250 x SP-A390 x x a a CSP-A290 x x x SP-A410 x CSP-A390 x x x x SP-A510 x x x x CSP-A410 x SP-A510-VG x x CSP-A510 x x x x SP-A700 x CSP-A700 x SP-A700-VG x x x x x x CSP-A700-VG x x x x x x SP-A710 x x CSP-A710 x x SP-A710-VG x x CSP-A780 x x x SP-A780 x x x CSP-A900 x SP-A900 x CSP-A1050 x x x SP-A1050 x x x CSP-A1050-VG x x x x x x SP-A1050-VG x x x x x x CSP-A1410 x SP-A1410 x CSP-A1550 x x x SP-A1550 x x x CSP-A1750 x SP-650 x CSP-A2150 x SP-B70 x CSP-A3600 x x x SP-880 x CSP-B110 x x x x SP-B90 x x x CSP-B150 x x x x SP-B110 x x x x CSP-B200 x x x x SP-B150 x x x x 'Note:All motors are rated for continuous use except model SP-050. SP-B200 x x x x SP-L50 x SP-L80 x 'Note:All motors are rated for continuous use except model SP-050. Greenheck Fan corporation certifies that he CSP models shown herein are licensed to bear Greenheck Fan Corporation certifies that the SP the AMCA seal.The ratings shown are based on models shown herein are licensed to bear the tests and procedures performed in accordance gm with AMCA Publication 211 and comply with AMCA seal.The ratings shown are based on tests eorewmr the requirements of the AMCA Certified Ratings 'Pr Of� and procedures performed in accordance with Program.The CSP models are not AMCA certified AMCA Publication 211 and AMCA Publication 311 with 50 hertz motors. r_ and comply with the requirements of the AMCA Certified Ratings Program.The SP models are not AMCA certified with 50 hertz motors. Products that cam the ENERGY STAR® ^ C 13 US LISTED prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S.Environmental Models SP and CSP are listed electric fans(UVcUL 507). Protection Agency and the U.S. LEARN MORE AT Ceiling Exhaust Fans are also UL Listed for above bathtub/ Department of Energy. energystar.g ov shower with GFCI branch protected circuit.File no.E33599. Note:SP/CSP fans are rated for direct contact with insulation. Fans that are ENERGY STAR certified include:SP-A70, SP-A90,SP-A110,SP-A125,SP-A190,SP-A200,SP-A250, SP-B70,SP-880,SP-890,SP-L50,SP-L80,SP-80-VG, SP-80L-VG,SP-110-VG,SP-110L-VG,SP-A50-90-VG, SP-A90-130-VG 6 r Vari-Green® Motor & Controls .,Value rnAi>f VARI-GREEN Vari-Green® Controls by GREENHECK Air Quality-VOC-Control a Vari-Green motor via changes in Volatile Organic Compounds(VOC's).VOC's are gasses that are emitted from humans, building materials, perfumes,foods, and furniture off-gassing. /4A,1 Range is 0-2000 CO2 ppm equivalent. . - • Institutional facilities-Schools,court houses, t hospitals; bathrooms, waiting rooms, cafeterias. • 0* • Commercial buildings-Offices, conference rooms, • %or bathrooms, break rooms. Air Quality-Temperature and Humidity-Control a Vari-Green motor via changes in temperature, humidity, or both. Range is 32°to 120°F and 0 to 100% relative Vari-Green® Motor humidity. EC Motor Technology Information&Advantages - • Multifamily structures-Apartments, condos, hotels; Greenheck's Vari-Green (VG) Electronically Commutated bathrooms, utility rooms. (EC) motor combines motor technology, controllability • Commercial buildings-Office buildings; offices, and energy-efficiency into one single low maintenance conference rooms, utility rooms, bathrooms. unit and is the industry's first fully controllable motor. Transformer- Provides 24V power from the existing The EC motor operates on AC power that is converted line voltage at the fan to the Vail-Green motor and to DC-providing more efficient motor operation as controls. Dual voltage primary(120/240V)transformer compared to an AC operation. The controllability of the provided with the fan. Vari-Green motor allows communication compatibility with a variable volume system. This allows speed Remote Dial or Touch Remote-Allows the user to adjustment of the motor to meet the needs of the manually adjust a fan's speed from a remote location system to exhaust air as needed and reduce over- and mounts to a wall using a 2x4 junction box.The exhausting conditioned air. 24VDC transformer, described above, is included with all orders. A wall cover plate is supplied. Available Vari-Green Controls and Models • The Touch Remote includes a countdown timer to automatically turn the fan off after 10, 30,60 or 90 minutes. SP/CSP-A510-VG Controls SP-80(L)-VG SP-A50-90-VG SP/CSP-A700-VG • Recommended for use in commercial buildings SP-110(L)-VG SP-A90-130-VG SP/CSP-A710-VG and restaurants. SP/CSP-A1 050-VG VOC X Two-Speed Control with Integral Transformer- Temperature/ Control allows motor RPM to be set at two independent Humidity X speeds(high or low). Meets minimum airflow Two-Speed X requirements with the ability to bump up to high speed Remote Dial x or meet maximum airflow requirements or reset to low speed for energy conservation. Touch Remote X Constant Pressure x Constant Pressure Control -Control Vari-Green motor via static(variable volume)or velocity(constant CFM) Transformer x pressure on the inlet or outlet side of the fan. Optional, Built-in Time Delay X one or two, duct or room probes for use in: Built-in Two Speed X • Multifamily structures-Apartments, condos, hotels; Constant Airflow X X X dryers, residential kitchens and bathrooms. 0-10v DC X • Institutional facilities-Schools, prisons, CFM Speed Selector X multistory office buildings; bathrooms. See Greenheck's Van-Green Motor and Vari-Green Controls brochures for more information. 7 .. Sound and Fan Selection a NH Things to know when sound is critical in Air.. Sound Data take into account the desired sound level at the The sound data shown in this catalog has been location of the listener. presented to aid the system designer in selecting a The compact size of the SP and CSP fans provides fan which will meet the desired sound criteria. Sone the system designer greater flexibility in locating these levels have been included on the performance pages fans for lowest sound levels. In to provide a means of quickly evaluating the relative critical sound areas, insulated loudness of a fan selection. ductwork, flexible duct connections, or placing Fiberglass W hat is a sone? Remote the fan in a remote . Sones are an internationally recognized unit of mounted of the ductwork modal CSP loudness. In practical terms, the loudness of one with vibration sone is equivalent to the sound of a quiet refrigerator (away from the critical nsulatedantl measured from five feet away in an acoustically average area) offers the best pduork ro a means of meeting the quietest room. A sone is a single number rating, indicating the desired sound levels. installation. inlet noise derived from the eight audible octave bands. Sones are a linear measurement of sound level. For Why are low sound levels important? example, a sound level of 10 sones is twice as loud as The main application of a ceiling exhaust fan under 5 sones. 200 cfm is typically to exhaust odor and humid air from Can radiated noise increase sound levels? a bathroom. If a bathroom fan is excessively loud,the Radiated noise from fan housings can cause occupant will seldom use it. Lack of proper venti—lation unacceptable sound levels on any brand of fan. The may leads , a variety cei ino concerns including damage to finishes, walls, ceilings and even health issues. size of these fans allows them to be placed in areas Greenheck is proud to offer some of the quietest fans where this noise will be transmitted to the conditioned on the market. space through walls or ceilings.Where possible, cabinet fans should be located in remote parts of the Why is Indoor Air Quality (IAQ) important? ventilation system. According to the United States Environmental Where should an SP or CSP fan be used? Protection Agency(EPA), the concentration of some Model SP and CSP are designed for the lowest pollutants are often 2 to 5 times higher indoors than possible sound levels.fansF are designed wheels, outdoors.The average American spends approximately insulated housings and vibration isolators between important. m 90/o Cant.f their time indoors,controlso IAQ is extremely t ly the motor and housing contribute to quiet, efficient and mild . Poor s that y cause may lead o mold and mildew issues that may health concerns. operation.Applied and installed as recommended, SP Seemingly harmless items such as building materials, and CSP sound levels will fall well within the ranges personal care items and cleaning agents may contribute shown in the Suggested Limits for Room Loudness to poor IAQ. Greenheck ceiling exhaust fans are chart. For applications where sound levels are critical, guaranteed to effectively exhaust moisture and odors a remote mounted CSP with ductboard is from your bathroom. recommended. Placement of SP and CSP fans should Suggested Limits for Room Loudness Sones dBA When room sound levels are critical, such 1.3-4 32-48 Private homes(rural and suburban) as in executive offices, conference rooms, 1.7-5 36-51 Conference rooms hospital operating rooms, and school study 2-6 38-54 Hotel rooms,libraries,movie theatres,executive offices areas, a CSP fan is the best choice. Shown 2.5-8 41-58 Schools and classrooms,hospital wards and operating rooms here is a comparison of SP and CSP fans of the same size, with equal performance in 3-9 44-60 Court rooms,museums,apartment houses,private homes q (urban) typical installations. The CSP shows lower 4-2 48-64 Restaurants,lobbies,general open offices,banks sone values. 5-15 51-67 Corridors and halls,cocktail lounges,washrooms and toilets 7-21 56-72 Hotel kitchens and laundries,supermarkets Model CFM WG FRPM Sones Reprinted from AMCA Publication 302(Application of Sone Ratings for Non-ducted SP-A410 405 1/8 1000 3.0 Air Moving Devices,with room-sone-dBA correlations)with the written permission from CSP-A410 403 1/8 1000 1.5 AMCA International,Inc.,30 West University Drive,Arlington Heights,IL 60004-1893. Sone value on CSP is with insulated inlet duct. NOTE:Values above are for room loudness and are not sound ratings.Room loudness is the resulting level In a conditioned space after the acoustical qualities of the room have been accounted for. 8 ENERGY STAR° Codes and Standards :. Value f ENERGY STAR® is a market-based partnership formed to reduce greenhouse gas emissions through energy efficiency and make it Products that earn the ENERGY STAR® prevent greenhouse gas emissions easier for consumers to identify energy-efficient products that offer ,f/ O by meeting strict energy efficiency savings, performance, features, and comfort. guidelines set by the U.S.Environmental To earn the ENERGY STAR label, products must meet strict energy- LEARN MORE AT Protection Agency and the U.S. energystar.gov Department of Energy. efficient standards set by the U.S. Environmental Protection Agency EPA for energyconsumption, air and soundperformance. Fan Fans that are ENERGY STAR certified include:SP-A70, (EPA) p SP-A90,SP-A110,SP-A125,SP-A190,SP-A200,SP-A250, models that are ENERGY STAR certified are identified in this catalog. SP-B70,SP-B80,SP-B90,SP-L50,SP-L80,SP-80-VG, SP-80L-VG,SP-110-VG,SP-110L-VG,SP-A50-90-VG, Note: ENERGY STAR is only for products 500 cfm or less. SP-A9o-130-vG Codes and Standards ASHRAE 62.2 sets the minimum Indoor Air Quality(IAQ)standards and minimum ventilation rates in commercial and residential buildings.This standard is used as the basis for state and local building codes such as the Washington State Energy Code. Select Greenheck fans are able to provide low speed continuous ventilation and cycle to high speed upon activation of a switch or a sensor. California Title 24 states that each bathroom shall be mechanically ventilated and shall comply with the following: Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. Humidity controls shall be capable of adjustment between a relative humidity range of less than or equal to 50 percent to a maximum of 80 percent. Multiple Greenheck ceiling exhaust fans can be used to comply with these latest codes and standards. Model Number Code The model number code system is designed to completely identify the fan.The remainder of the model code is determined by the size and performance of the fan. SP - A50L - VG Model I ( L Vari-Greene SP-Silent Partner EC Motor Option CSP-Cabinet Silent Partner Light Options Level of Construction LED-Fan/Light(LED)Combination No letter designation identifies model as Premium Plus with a sari-Green motor A- Premium unit;lowest sound,insulated housing Nominal cfm at 0.10 inches static pressure t3- Deluxe unit;low sound, low profile L- Low Profile,ceiling/wall mounted C- Economy unit; inexpensive 9 Model SP-VG �`; , IH�. Premium Ceiling Exhaust Fan in Air " ► Model SP-VG Model SP-VG Dimensions SP-VG 80,110I. Model A B C D E Designer Unit ' Grille Weight ,, FOND 80 L 11s/s 10'/z Ns - 4 14 x 13 12 {/ I E� �•aa 1 ii O (289) (267) (194) (102) (356 x 330) (5) I �N���� 110(L) 11% 101 7% 6 - 14 x 13 12 C p"1 CERTIFIED (289) (267) (194) (152) (356 x 330) (5) All Outlet dimensions are in inches(millimeters)inmm) and weight in pounds(kilograms). — �'�?� For concomplete tion width is 1 o.(25 n, Mounting bracketsubmftal widthw is . in.(38 mm). `, 11 US LISTED For complete dimensional information,see CAPS submittal drawings. *Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model SP-VG Performance Model ENERGY HVI RPM Amps' Max.ax. CFM/Static Pressure in Inches wg STAR® Watts' 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 SP-80(L)-VG ,A- + 935 0.1 6.1 CFM 80 80 80 80 78 66 38 Sones <0.3 <0.3 <0.3 0.6 1.4 2.2 3.0 SP-110(L)-VG A + 940 0.2 8.4 CFM 110 110 110 109 100 62 28 Sores <0.3 <0.3 <0.3 1.4 2.3 3.0 3.6 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. i(1 4 Model SP-A-VG F; i ,, .. Premium Constant CFM Ceiling Exhaust Fan Model SP-A-VG SP-A50-90-VG Model SP-A-VG Dimensions ra SP-A90-130-VG Model A B C D E Designer Decorative Unit Grille Grille Weight 1111) „-iB ` A-,,� ENERGY STAR 101 ww.pu« SP-A50-90-VG 13rA 10% 9 6 14%x 13% 15/(387) 12 (337) (270) (229) (152) (378 x 337) square (5) SP-A90-130-VG -,. All dimensions are in inches(millimeters)and weight in pounds(kilograms). ��- C (31 US LISTED Outlet connection width is 1 in.(25 mm).Mounting bracket width is 11/2 in.(38 ram). For complete dimensional information,see CAPS submittal drawings. *Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model SP-A-VG Performance ENERGY CFM Max Max CFM/Static Pressure in Inches wg Model STAR® Selection RPM Amps* Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 CFM 50 50 50 50 50 50 50 50 50 50 808 0.29 22.1 Sons <0.3 <0.3 0.6 0.7 1.5 2.0 2.0 2.5 2.5 CFM/Watt' 56.5 20.7 17.3 9.9 6.5 5.4 4.0 3.4 2.9 Watts' 1.2 3.2 3.7 5.5 8.3 10.9 14.3 17.9 21.7 CFM 70 70 70 70 70 70 70 70 66 SP " 70 838 0.30 23.3 Sones <0.3 <0.3 0.4 0.9 1.4 2.0 2.0 3.0 2.5 A50-90-VG CFM/Watt' 56.2 19.7 17.4 10.4 7.2 5.4 4.2 3.5 3.0 Watts* 1.6 4.3 4.8 7.6 10.8 14.3 17.7 22.1 22.1 CFM 90 90 90 90 90 90 90 82 71 90 887 0.31 24,1 Sones <0.3 0.5 0.6 1.0 1.5 2.0 2.0 2.5 2.5 CFM/Watt* 28.7 18.1 15.4 10.4 7.0 5.4 4.5 3.6 3.2 Watts* 3.8 5.6 6.5 9.3 13.4 17.8 21.6 22.5 22.3 CFM 90 90 90 90 90 90 90 82 71 90 887 0.31 24,1 Sones <0.3 0.5 0.6 1.0 1.5 2.0 2.0 2.5 2.5 CFM/Watt' 28.7 18.1 15.4 10.4 7.0 5.4 4.5 3.6 3.2 Watts* 3.8 5.6 6.5 9.3 13.4 17.8 21.6 22.5 22.3 CFM 110 110 110 110 110 110 102.5 62 67 SP 110 960 0.31 24.2 Sones 0.4 0.9 0.8 1.3 1.5 2.5 2.5 2.5 2.5 A90-130-VG CFM/Watt` 22.7 14.7 13.3 9.4 6.9 5.3 4.4 3.5 3.1 Watts* 5.6 8.4 9.1 12.7 17.0 22.1 23.4 23.4 22.2 CFM 130 130 130 130 130 122.7 99.1 80.8 63.7 130 1041 0.32 24.2 Sones 1.2 1.4 1.5 2.0 2.5 3.0 2.5 2.5 2.5 CFMW/att' 16.2 12.0 11.1 8.5 6.2 5.1 4.2 3.4 3.0 Watts* 9.1 11.7 12.7 16.4 22.4 23.9 23.5 23.5 22.4 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sons at 5 ft(1.5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. 11 Model SP-A '� rH, Premium Ceiling Exhaust Fan . LLlna� Model SP-A Dimensions SP-A 50-90 SP-A 110-510,510-VG, Model A B C D E Designer Decorative Unit g A 710-VG,710,780 Grille Grille Weight / _g �A 50,7D,90 13'/a 105/a 9 6 12 ��� I E1I (337) (270) (229) (152) (5) 13% 10% 9 8 6 141/a x 131/ 15Y 387 17 C '�'" E 11Q, 125,190 ( ) D (337) (270) (229) (203) (152) (378x337) square (8) 200,250,290, 14 1 P/a 11'/a 8 8 24 , ��, C --I 390 (356) (302) (286) (203) (203) (11) 410,510' 18 14% 14% 8 8 19%x16% 31 510-VG, (457) (365) (368) (203) (203) (492 x 416) (14) 710-VG 23% 11% 11% 19Y2 8 25Ya x 13'/ 34 SP-A 700,700-VG, 1050-VG,900-1550 700,700-VG (600) (295) (295) (495) (203) (638 x 343) (15) ft, 710 780 18 14% 14'h 10 8 19'%x 16%A 34 B/1� (457) (365) (368) (254) (203) (492 x 416) (15) 900,105Q , �A� 1DRRD 1D50-VG, 23% 14% 14/2 17/u 8 25 x 16% 56 E MED 1410,1550 (603) (365) (368) (443) (203) (635 x 416) (25) ® hilit: ; i HI■ All dimensions are in inches(millimeters)and weight in pounds(kilograms). NVt Outlet connection width is 1 in.(25 mm).Mounting bracket width is 1Y2 in.(38 mm). C D CERTIFIED For complete dimensional information,see CAPS submittal drawings. 1 C CO US LISTED k flk c Pak 1 4 illri •ra'br y,, a y. ✓(� � r`% { i, ' -� A. ySt ' ra ' ;' x,. ., ., 'x' 4 tea l rT y , y .,Ei3s.�.. ?` 1 12 � Model SP-A ,��h. Premium Ceiling Exhaust Fan Value, •Continuous Ventilation Compatible: Low speed continuous operation is adjustable from 30 cfm to full rated fan speed *Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. ENERGYContinuous Max. CFM/Static Pressure in Inches w Model HVI Ventilation Control RPM Amps* Input ST9 STAR Compatible Voltage Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 1.25 SP-A50 + 790 0.33 25.9 CFM 89 66 61 31 Sones 0.4 0.6 0.6 0.9 CFM 88 74 71 54 SP-A70 790 0.14 15.6 Sones <0.3 <0.3 <0.3 <0.3 CFM/Watt* 5.64 4.97 4.83 4.12 Watts* 15.6 14.9 14.7 13.1 CFM 114 101 98 80 SP-A90 f.`[ + • 870 0.14 16.9 Sones <0.3 <0.3 <0.3 0.4 CFM/Watt* 6.75 6.20 6.95 5.33 Watts* 16.9 16.3 14.1 15 CFM 130 119 115 98 SP-A110 Yxf ♦ 950 0.16 19.4 Sones <0.3 <0.3 <0.3 0.5 CFM/Watt* 6.70 6.33 6.15 5.54 Watts* 19.4 18.8 18.7 17.7 CFM 144 130 127 109 SP-A125 1010 0.19 23 Sones 0.4 0.4 0.4 0.6 CFM/Watt* 6.26 5.73 5.62 5.00 Watts* 23.0 22.7 22.6 21.8 CFM 229 214 210 186 156 SP-A190 1400 0.45 54.2 Sones 2.5 2.0 2.0 2,0 1.5 CFM/Watt* 4.23 4.08 4.05 3.78 3.36 Watts* 54.2 52.5 51.9 49.2 46.4 I,IM 267 246 242 224 199 162 109 68 SP-A200 f`s 900 0.47 56.1 Sones 2.0 2.0 2.0 2.5 3.0 3.5 4.0 4.5 CFM/Watt* 4.76 4.42 4.34 4.10 3.75 3.19 2.29 1.49 Watts* 56.1 55.7 55.7 54.7 53.1 50.8 47.6 45.7 CFM 294 274 271 250 230 201 147 92 SP-A250 1000 0.56 67 Sones 2.5 2.5 2.5 3.0 3.5 4.0 5.0 5.0 CFMNVatt* 4.39 4.18 4.12 3.89 3.67 3.36 2.65 1.80 Watts* 67.0 65.6 65.8 64.2 62.6 59.8 55.4 51.2 SP-A290 1050 0.72 80.7 CFM 315 293 287 257 231 207 175 124 Series 2.5 2.5 2.5 3.0 3.0 3.5 3.5 4.5 SP-A390 1350 1.34 135 CFM 410 395 391 368 345 325 307 279 Sones 4.5 4.5 4.5 4.5 5.0 5.0 5.5 5.5 SP-A410 1000 1.74 121 CFM 443 413 405 351 306 Sones 3.5 3.0 3.0 3.0 3.5 SP-A510 1070 3.30 224 CFM 557 512 501 439 392 325 Sones 5.0 4.5 4.5 4.5 4.5 4.0 850 0.75 49,1 GEM 399 354 341 255 SP-A510-VG Sones 4.5 4.0 3.9 3.4 1275 2.40 155 CFM 604 583 576 540 495 443 377 Sones 7.9 7.7 7.7 7.3 7.0 6.8 6.4 SP-A700 1100 3.20 350 CFM 757 730 723 700 679 649 613 560 494 396 Sones 5.0 5.0 5.0 5.5 5.5 6.0 6.0 6.5 6.5 6.5 6 1275 1.82 111 CFM 568 527 517 466 419 372 329 275 223 170 100 SP-A700-VG Sones 3.5 3.5 3.5 3.5 4.0 4.5 5.0 6.0 7.0 7.0 9.0 10 1450 3.52 218 CFM 801 774 766 729 699 666 634 597 569 530 418 Sones 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.5 7.5 8.0 9.0 SP-A710 1080 4.40 285 CFM 752 714 701 653 588 466 320 Sones 6.0 6.0 6.0 6.0 6.0 5.5 5.5 925 0.96 60.4 CFM 441 410 397 327 SP-A710-VG Sones 4.5 4.3 4.2 4.0 1450 3.39 230 CFM 709 685 677 656 621 580 534 483 399 Sones 9.6 9.4 9.2 9.0 8.7 8.6 8.3 8.1 7.8 SP-A780 1600 3.30 348 CFM 812 782 775 741 704 665 625 581 Sores 8.5 8.5 8.5 8.0 8.0 8.0 8.0 8.0 SP-A900 950 4.00 285 CFM 955 907 896 841 773 701 Sores 4.0 5.0 5.0 5.0 5.0 5.0 SP-A1050 1095 6.30 420 CFM 1125 1059 1043 964 885 796 662 Sones 6.0 6.0 6.0 6.0 5.5 5.5 5.5 6 1050 1.94 120 CFM 838 789 779 735 685 632 579 SP-A1050-VG Sones 4.0 4.0 4.0 4.0 4.0 4.5 5.0 10 1225 3.75 240 OEM 1162 1106 1092 1023 944 831 668 Sones 7.5 7.0 7.0 7.0 6.5 6.0 5.0 SP-A1410 1450 7.40 786 CFM 1455 1415 1404 1353 1307 1262 1218 1174 Sones 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10,0 5P-A1550 610 8.60 g18 CFM 1607 1558 1558 1506 1449 1407 1369 1323 Sones 10.5 10.0 10.0 10.0 10.0 10.5 11.5 13.0 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sores at 5 ft(1.5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. 13 Model SP-B and SP-C �'- , v i4 # , ., Deluxe and Standard Ceiling Exhaust Fan ;r,Ar� Model SP-B Model SP-B Dimensions t Designer Decorative Unit fB �A st*ts. Model A B C D E t ,. �<;.;�. c. lOuno Grille Grille Weight . D C ".,*�Ip 50,70,80 n. 13% 11'% 7 6 1'/4 9 j �u' (352) (292) (179) (1521 (32) 14%x 13'/4 15Ya 087) (4) j!�i NTV�p 90,110,150, 137/a 11% 7 6 1'/4 (378 x 337) square 10 o i�i�G ( ) (179) (152) (32) (5) �i-/�i�� �-i- ... 200 352 292 _ All dimensions are in inches(millimeters)and weight in pounds(kilograms).Mounting bracket width i��i/-' is 11 in.(38 mm).For complete dimensional information,see CAPS submittal drawings. C 1:00 US LISTED *Continuous Ventilation Compatible: Low speed continous operation is adjustable from 30 cfm to full rated fan speed 'Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model SP-B Performance ENERGY Continuous Max. CFM/Static Pressure in Inches wg Model STD® HVI Ventilation RPM Amps* Input Compatible Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 SP-B50 + • 625 0.50 37.8 CFM 67 54 51 40 29 Sores 1.2 1.4 1.4 2.0 3.0 CFM 89 75 71 54 35 Sones 0.8 0.8 0.9 1.4 2.0 SP-B70 + 675 0.16 17.1 CFM/Watt* 5.20 4.46 4.25 3.27 2.27 Watts* 17.10 16.80 16.70 16.50 15.41 CFM 94 81 77 62 46 SP-B80 A A. • 900 0.16 18.6 Sones 0.8 0.9 0.9 1.3 2.0 CFMANatt* 5.05 4.40 4.21 3.44 2.71 Watts* 18.60 18.40 18.30 18.00 16.95 CFM 104 92 89 72 57 SP-B90 ' + 700 0.18 21.1 Sones 1.0 1.0 1.0 1.5 2.0 CFM/Watt* 4.93 4.40 4.24 3.48 2.88 Watts* 21.10 20.90 21.00 20.70 19.77 SP-B110 + • 950 1.14 80.2 CFM 133 114 110 97 95 94 91 85 72 50 Sones 1.5 1.5 1.5 2.0 2.0 2.0 3.0 3.5 4.0 4.5 SP-B150 1050 1.70 128 CFM 160 156 155 154 152 149 147 138 123 92 Sones 2.5 2.5 2.5 3.0 3.5 3.5 4.0 4.5 4.5 5.0 SP-B200 1100 220 172 CFM 197 195 194 191 187 184 181 166 151 128 Sones 3.5 4.0 4.0 4.5 4.5 5.0 5.0 5.5 5.5 5.5 Performance certified is for model SP exhaust for installation type B.Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m) in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. Model SP-C Model SP-C Dimensions . B \A Model A B C D E F Decorative Unit �(� D Grille Weight round 50 7'% 7% 3% 3 Ws 1/2 91/4x 9 5 Lek "'° °u' (1 (797) (92) (76) (47) (13) (235 x 229) (2) All dimensions are are in inches(millimeters)and weight in pounds(kilograms).For ~TV'e complete dimensional information,see CAPS submittal drawings. *Note:Amp draw is approximate and may vary based on motor manufacturer. F US LISTED Model SP-C Performance CFM/Static Pressure in Inches wg Model HVI RPM Amps* Watts 0 0.1 0.125 0.25 0.375 0.5 0.625 SP-050 + 1680 0.80 46 CFM 52 49 49 47 44 38 29 Saves 3.0 3.0 3.0 3.0 3.5 4.0 4.0 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper.Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sores at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. 14 Model SP-L and CSP-B , Deluxe Inline Cabinet Fan r ` > :L. Value ` ` Model SP-L \ Model SP-L Dimensions �F-:'F`E� °°"' mm Designer Unit A ♦ Y fib MUM Model A B C D E F \, Grille Weight �B ,D �- au 50,80 13,A 11 IA 3% 2% 4'/,e 3/s 14'/s x 13/ 9.5 v, (352) (292) (92) (67) (113) (86) (378x337) (4) GEMMED All dimensions are in inches(millimeters)and weight in pounds(kilograms). For complete dimensional information,see CAPS submittal drawings. C CO US LISTED *Note:Amp and watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. j Model SP-L Performance ENERGY Max. CFM/Static Pressure in Inches wg Model H1N. aM Amps* Input r..Z X3� ;-11 ,ry ' Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 1 s . CFM 62 53 51 41 31 19 SP-L50 `;`r + 800 0.17 17.8 Sones 1.0 1.2 1.3 2.0 3.0 3.5 CFM/Watts 3.48 2.99 2.91 2.38 1.85 1.15 Watts 17.8 17.7 17.5 17.2 16.8 16.5 CFM 86 78 76 67 57 46 33 SP-L80 - + 850 0.23 26.8 Sones 1.5 2.0 2.0 2.0 2.5 3.5 4.0 CFM/Watts 3.21 2.92 2.85 2.54 2.19 1.78 1.30 Watts 26.8 26.7 26.7 26.4 26.0 25.8 25.4 Performance certified is for model SP exhaust for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille and backdraft damper. Speed(rpm)shown Is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type B:free inlet spherical fan sone levels. Model CSP-B Inlet D -diameter Model CSP-B Dimensions FxG Model A BCDE F G Unit •� �I Weight 1C 110,150,200 13'/e 11'/z 7 6 1'/a 13'/z 3'/4 10'1a I I ����'lE i (352) (292) (178) (152) (32) (260) (83) (5) Illi::. All dimensions are in inches(millimeters)and weight in pounds(kilograms). �� Inlet connection width is 1 inch(25 mm).Mounting bracket width is 1 K in.(38 mm). For complete dimensional information,see CAPS submittal drawings. B I /� �� C CO US LISTED `Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Model CSP-B Performance Max. CFM/Static Pressure in Inches wg Model RPM Amps* Input Watts* 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 GEM 103 100 100 98 97 96 94 86 CSP-8110 950 1.14 80 Sones 1.5 1.5 1.5 2.0 2.0 2.0 2.5 2.5 Watts" 92.3 92.2 92.2 92.1 92.0 92.0 91.9 91.4 CFM 151 150 149 148 144 146 142 135 CSP-B150 1050 1.70 129 Sones 2.0 2.0 2.0 2.0 2.5 2.5 3.0 3.0 Watts' 145.0 145.0 145.0 145.0 144.9 144.9 144.9 144.7 CFM 186 184 184 182 181 179 175 170 CSP-B200 1100 2.20 173 Sones 3.0 3.0 3.0 3.0 3.5 3.5 3.5 3.5 Watts' 183.0 182.4 182.4 181.8 181.5 180.9 179.7 178.2 Performance certified is for model CSP inline for installation type D:Ducted inlet,Ducted outlet.Performance ratings include the effects of a backdraft damper. Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type D:ducted inlet spherical fan sone levels.Ratings do not include the effect of duct end correction.Ratings are based on 10 ft of insulated duct. 15 Model CSP-A Premium Inline Cabinet Fan ,_a in Aar Model CSP-A Dimensions CSP-110-510,510-VG, Fe00 . 710,710-VG,780 Model A BCDEF G Unit Weight 13' ( 8 5 12 9'/4 16 110,125,190 C' IFr (337)7J (270)70) (229) (203) (152) (305) (236) (7) 200,250,290, 14 11% 111/4) 8 8 12% 10 23 f11 p�1 ° remote (356) (302) (286) (203) (203) (327) (254) (10) i 410,510, 18 14% 14'/ 8 8 16% 13'/a 36 1 Df l remotea 510-VG,710-VG (457) (365) (368) (203) (203) (429) (337) (16) B A „,,:4,,,,, 66. 700,700-VG 235 11% 11% 191/2 8 22% 101/2 34 (600) (295) (295) (495) (203) (575) (267) (15) 71 Q,780 18 14% 14'% 10 8 16% 13'/a 36 CSP-700,700-VG, C L'J US LISTED (457) (365) (358) (254) (203) (429) (337) (16) 1050-VG, �� 900,1050, (�`I A 900-3600 1050-VG, 23s/< 14'/r l4'/z 1T/,F 8 227a 13'/a 59 141D,1550 (603) (365) (368) (443) (203) (575) (337) (27) 1� 1750,2150 14'/4 14% 28 6 32a/4 13 68 �+ D kl--t- 35 (889) (375) (375) (711) (152) (832) (330) (31) \ ''',,IC( ( 40 11 ( ) (2)3600 (1156) (419) (419) (1016) (279) (1099) (377) (55) All dimensions are in inches(millimeters)and weight in pounds(kilograms).Inlet and outlet F connection widths are 1 in.(25 mm).Mounting bracket width is 11/2 in.(38 mm). Inlet / For complete dimensional information,see CAPS submittal drawings. r 16 ,. y�WYrww..... F r Model CSP-A Premium Inline Cabinet Fan • :.:. Valued 'Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 115V. Control Max. CFM/Static Pressure in Inches wg Model Voltage RPM Amps* Input 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1.0 1.25 Watts* CFM 124 112 110 102 77 CSP-A110 950 0.62 20 Sores 0.8 0.8 0.8 0.9 0.9 Warts' 20.3 20.0 19.9 19.7 18.4 CFM 138 126 124 114 91 CSP-A125 1100 0.63 23 Sones 1.1 1.1 1.1 1.0 1.2 Walls' 22.5 22.3 22.2 22.1 21.3 CFM 215 202 198 180 159 121 CSP-A190 1400 1.10 55 Sores 2.0 1.5 2.0 2.0 2.5 2.5 Watts 55.1 54.1 53.7 51.9 49.8 46.0 CFM 254 231 226 203 178 145 109 70 CSP-A200 900 0.43 58 Settee 0.6 0.4 0.5 0.9 1.0 1.3 1.5 1.5 Walls 57.9 57.3 57.1 56.1 54.6 52.5 50.3 48.0 CFM 266 246 241 221 205 187 165 132 CSP-A250 1000 0.79 67 Sores 0.9 1.0 1.0 2.0 2.5 3.0 2.5 2.5 Watts' 66.5 65.6 65.4 64.0 62.7 61.2 59.4 56.6 CFM 318 299 292 265 248 229 201 144 CSP-A290 1050 0.71 102 Sores 1.1 1.2 1.3 2.0 2.5 3.5 3.0 3.0 Watts' 102.2 100.9 100.4 98.3 96.9 95.0 90.5 81.3 CFh1 412 400 397 382 363 339 324 309 CSP-A390 1350 1.33 161 Sores 2.0 2.0 2.0 2.5 3.0 4.0 4.5 4.5 Walls' 160.8 158.5 157.9 152.4 147.9 141.8 135.4 130.0 CFM 447 441 403 364 317 217 CSP-A410 1000 1.87 32 Series 1.5 1.5 1.5 2.0 2.0 2.0 Watts' 132.2 131.7 128.7 125.6 120.5 112.4 CFM 545 514 506 464 405 324 CSP-A510 1070 3.11 218 Sones 2.5 2.0 2.0 2.0 2.0 2.5 Watts' 218.2 214.3 213.3 207.0 196.4 182.8 CFO 428 358 338 238 850 0.86 55 Sores 0.8 0.6 0.5 0.3 CSP-A510-VG Watts" 54.8 48.9 47.0 35.8 CFM 621 590 583 540 479 414 328 1275 2.40 160 Sores 1.5 1.4 1.4 1.3 1.2 1.5 1.7 Watts' 154.4 159.6 160.1 156.1 140.7 123.1 99.9 CFM 766 755 752 739 726 702 678 635 549 418 CSP-A700 1100 3.20 352 Sores 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.5 4.0 Watts' 352.1 350.7 350.3 348.7 346.3 340.7 332.6 315.5 289.1 256.1 CFO 625 570 558 504 450 402 348 261 213 167 67 6 1275 1.83 110 Sones <0.3 <0.3 <0.3 <0.3 <0.3 0.8 1.1 1.5 2.0 2.5 3.0 CSP-A700-VG Watts' 55.6 58.7 60.0 63.5 69.4 76.5 83.8 89.5 95.3 101.0 108.2 CFM 895 857 848 803 760 725 688 647 604 556 479 10 1450 3.53 216 Saws 1.0 1.0 1.0 1.0 1.0 1.2 1.5 1.5 2.0 2.5 3.0 Watts" 157.1 160.6 161.3 168.5 169.4 173.1 179.9 187.1 193.6 201.4 215.3 CFM 737 698 688 635 567 475 334 CSP-A710 1080 4.40 333 Scores 2.5 2.5 2.5 2.5 2.0 2.0 2.0 Watts' 332.5 324.1 322.0 310.8 295.8 277.4 255.2 CFM 470 415 405 322 925 1.08 68 Sones 0.6 0.4 0.4 0.4 CSP-A710-VG Watts' 67.8 61.2 60.6 49,0 CFM 730 699 690 654 622 574 514 446 349 1450 3.51 236 Sones 2.2 2.1 2.1 2.0 1.9 2.1 2.4 2.7 2.8 Watts' 236.0 234.2 231.4 223.1 218.9 200.8 180.0 156.8 119.9 CFM 813 784 777 742 707 672 638 603 567 527 CSP-A780 1600 3.77 496 Sones 3.0 3.0 3.0 3.0 3.0 2.0 3.0 3.0 3.0 3.5 Watts' 496.4 493.0 492.2 488.0 467.5 453,1 441.8 423.1 407.2 CFM 908 852 841 782 715 631 CSP-A900 950 4.87 335 Sones 1.4 1.4 1.4 2.0 2.5 3.0 Watts' 335.0 288.6 286.0 272.7 259.9 245.5 CFM 1182 1110 1093 1013 922 832 743 CSP-A1050 1095 6.65 469 Sones 2.5 2.5 2.5 2.5 2.5 2.5 2.5 Watts* 468.8 455.9 453.3 440.8 424.9 411.0 399.2 CFM 805 754 741 689 642 597 547 6 1050 1.90 115 Sones <0.3 <0.3 <0.3 0.4 0.5 1.0 1.5 CSP-A1050-VG Watts' 79.8 85.2 85.0 91.4 97.4 105.5 114.9 CFM 1131 1105 1092 1047 998 900 758 10 1225 3.85 241 Cones 1,0 0.9 0.9 1.0 1.2 1.3 1.4 Watts' 220.7 231.5 231.5 239.7 239.9 216.7 173.9 CFM 1584 1543 1533 1483 1439 1395 1345 1293 1238 1181 CSP-A1410 1450 7.80 871 Sones 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 4.0 4.0 Watts' 870.8 837.9 829.9 788.2 751.0 728.3 696.3 661.8 628.8 595.9 CFM 1672 1618 1604 1543 1484 1427 1367 1307 1240 1172 CSP-A1550 1610 8.32 913 Sores 5.0 4.5 4.5 4.5 4.5 4.0 4.0 4.5 4.5 4.5 Watts' 912.8 877.4 868.4 829.3 802.9 778.0 744.3 710.7 679.1 647.4 CFM 1842 1768 1749 1619 1464 1284 1032 772 484 CSP-A1750 1130 6.60 600 Sones 5.0 5.0 5.0 4.5 4.0 4.0 3.5 3.0 3.0 Watts' 599.8 570.5 563.0 515.0 470.9 420.3 366.1 317.2 276.5 CFM 2249 2175 2156 2044 1900 1701 1424 1114 I CSP-A2150 1100 7.80 761 Some 5.0 4.5 4.5 4.0 4.0 4.0 3.0 3.0 Watts' 760.8 731.5 724.0 679.7 622.7 544.0 459.7 382.3 • CFM 3778 3653 3622 3460 3280 3091 2844 2551 2232 1750 CSP-A3600 1100 7.10 1314 Sones 5,0 5.0 5.0 5.0 4.5 4.0 4.0 4.0 3.5 3.5 Watts 1313.7 1253.3 1238.3 1160.0 1084.0 1041.5 971.1 871.9 766.5 649.5 Performance certified is for model CSP inline for installation type D:Ducted inlet,Ducted outlet.Performance ratings include the effects of a backdraft damper. Speed(rpm)shown is nominal.Performance is based on actual speed of test.The sound ratings shown are loudness values in spherical fan sones at 5 ft(1.5m)in a spherical free field calculated per Annex B of AMCA 311.Values shown are for installation type D:ducted inlet spherical fan sone levels.Ratings do not include the effect of duct end 1 7 correction.Ratings are based on 10 ft of insulated duct. A Pt, Model SP I H . ., � r 50 Cycle Performance '* inAfr �` For uses in countries with 50 cycle (50 Hz) power, SP-A 110-510,510-VG, Greenheck offers the same reliability and performance 710,710-VG,780 for ceiling mounted exhaust fans model SR. /B�I� A • Same dimensions and outlet optionsN. • Performance shown in 50 cycle RPMs i E NI i -4 1 • Full-line of grille and discharge accessories available C /� �� Model SP Dimensions SP-A 700-VG,1050-VG, I// SP-A A B C D E Designer Decorative Unit 900-1550 Grille Grille Weight 110 125,190 13'4 10% 9 8 6 17 r A (337) (270) (229) (203) (152) 14%x 13'/ 15%(387) (8) I/ t 200 250,290 390 14 11% 11/° 8 8 (378x337) square 24 / (356) (302) (286) (203) (203) (11) 1 l. 410,510, 18 14% 14% 8 8 19%x 16% 31 C. DQ 510-VG,710-VG (457) (365) (368) (203) (203) (492 x 416) (14) 700-VG 23% 11% 11% 191/28 251/2 x 131/2 34 (600) (295) (295) (495) (203) (638 x 343) (15) 710,780 18 14% 14% 10 8 19B%x 16% 34 (457) (365) (368) (254) (203) (492 x 416) (15) 900,1050,1050-VG, 23% 14/a 141/2 18% 8 25 x 16% 56 1410,1550 (603) (365) (368) (476) (203) (635 x 416) (25) SP-8 50-200 Outlet connection width is 1 in.(25 rum).Mounting bracket width is 1Yx in.(38 min). B�,�A SP-B A B C D E Designer Decorative Unit04011: D c Grille Grille Weight 14%7 6 1 1'/B 11'h '/a x 3'/� 50,70,80 13 9 i� • 90,110, 13% 11Yr (178) (152) (32)114%x 13Ya lsqu(a e 1a0 *i��i/--� -�i 150,200 (352) (292) (152) (152) (32) (378 x 337) (5) �iy��//ji All dimensions are in inches(millimeters)and weight in pounds(kilograms)-Mounting bracket width is 11/in.(38 mm).For complete dimensional information,see CAPS submittal drawings. `Note:Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 220-240V. Model Control Max. CFM/Static Pressure in Inches of wg (so Hertz Motor) Voltage RPM Amps* Input 0.000 0.050 0.100 0.125 0.150 0.250 0.375 0.500 Watts* SP-A110 950 0.29 qg CFM119 115 110 106 103 68 Sones 1.3 1.3 1.2 1.2 1.3 1.6 SP-A190 1400 0.ac 113 CFM 216 206 197 192 187 167 133 Sones 3.2 3.0 2.8 2.9 2.9 3.1 3.4 SP-A290 1050 0.36 81 CFM 329 315 302 296 290 262 222 164 Sones 3.2 3.3 3.3 3.3 3.4 3.7 4.0 4.9 SP-A390 1350 0.67 135 CFM 410 402 395 392 387 368 345 325 Saner 5.4 5.4 5.4 5.4 5.5 5.7 6.0 6.3 SP-A510 900 1.65 224 ChM447 425 400 388 376 315 159 Sones 3.7 3.5 3.3 3.3 3.3 3.1 2.6 850 0.75 49 CFM 399 375 354 341 320 255 Sones 4.5 4.3 4.0 3.9 3.7 3.4 SP-A510-VG CF1.1 604 595 583 576 567 540 495 443 1275 2.40 155 Sones 7.9 7.8 7.7 7.7 7.5 7.3 7.0 6.8 6 1275 1.82 111 CFM 568 548 527 517 492 466 419 372 SP-A700-VG Sones 3.5 3.5 3.5 3.5 3.5 3.5 4.0 4.5 10 1450 3.52 218 CFO 801 788 774 766 748 729 699 666 Saner 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 925 0.96 60 CFM 441 425 410 397 379 327 SP-A710-VG Sones 4.5 4.4 4.3 4.2 4.2 4.0 1450 3.39 230 CFM 709 697 685 677 671 656 621 580 Sones 9.6 9.5 9.4 9.2 9.2 9.0 8.7 8.6 SP-A780 1334 1.65 348 CFM 677 659 642 633 625 591 544 493 Stones 8.8 8.9 8.8 8.7 8.6 8.2 8.1 8.1 SP-A1050 950 3.15 420 CFM 990 945 905 886 867 769 531 Sones 7.2 7.0 6.8 6.8 6.8 6.6 6.5 6 1050 1.94 120 CFO 838 814 789 779 757 735 685 632 SP-Al -VG Sones 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 10 1225 3.75 240 CFM 1162 1134 1106 1092 1058 1023 944 831 Sores 7.5 7.5 7.0 7.0 7.0 7.0 6.5 6.0 SP-A1550 1340 4.3 818 CFM 1337 1314 1290 1279 1266 1211 1161 1112 Sores 11.1 10.7 10.6 10.6 10.6 10.5 11.6 13.5 SP-B90 700 0.325 50 CFM 102 97 92 88 as 75 59 as Sones 1.9 2.2 2.6 2.7 2.7 3.0 3.6 4.1 SP-B110 950 0.57 80 CFM 133 124 114 110 107 97 95 94 Sones 2.0 2.0 2.1 2.2 2.2 2.4 2.7 2.8 SP-6150 1050 0.85 129 CFO 160 158 156 155 155 154 152 149 Sones 3.0 3.1 3.3 3.3 3.4 3.7 4.3 4.5 SP-B200 1100 1.1 173 CFM 197 196 195 194 194 191 187 184 Sores 4.4 4.7 4.6 4.7 4.9 5.1 5.6 5.8 18 . r fie Model CSPN. 50 Cycle Performance 1. " Value r Je. ► - ' . _ For uses in countries with 50 cycle (50 Hz) power, CSP-A 110-510, 510-VG, Greenheck offers the same reliability and performance 710,710-VG,780 for inline cabinet fans model CSP. Fes\ • Same dimensions and outlet options 1 , ' p • Performance shown in 50 cycle RPMs G ( IC • Full line of discharge accessories available f I/ I ii D� i Model CSP Dimensions CSP-A 700-VG,1050-VG I,� CSP-A A B C D E F G Unit 900-3600 g p' Weight �� 110,125,190 1314 10% 9 8 6 12 9 16 g (337) (270) (229) (203) (152) (305) (235) (7) ��A` 20Q,250,290,390 14 11% 11'/4 8 8 12% 10 23 I�I `mil (356) (302) (286) (203) (203) (327) (254) (10) G 1D�� 410,510, 18 (14%365) 14'/2 8 8 16'/a 137) 36 I. 570-VG,710-VG (457) (365) (368) (203) (203) (429) (337) (1s) � 700-VG 23% 11% 11% 19Y2 8 22% 10'/2 34 C (600) (295) (295) (495) (203) (575) (267) (15) 710,780 18 14% 14'/2 10 8 16% 13'/4 36 (457) (365) (368) (254) (203) (429) (337) (16) Inle�/ 900,1050,1050-VG, 231/4 14% 141/2 181/4 8 22% 131/4 59 1410,1550 (603) (365) (368) (476) (203) (575) (337) (27) CSP-B 1750,2150 35 14% 14'/4 28 6 32% 13 68 Inlet D-diameter (889) (375) (375) (711) (152) (832) (330) (31) Fx\G 3600 45Y2 16'/2 16/e 40 11 4314 14% 122(1156) (419) (419) (1016) (279) (1099) (371) (55) CSP-B A BCDE F G Unit Weight (I 5 IIE 110,150,200 (52) 112) 7 6 ('2) (60) 33) 1(5)/4 I / (352) (292) (778) (152) (32) (260) (83) (5) All dimensions are in inches(millimeters)and weight in pounds(kilograms).Inlet and outlet �f connection widths are 1 in.(25 min).Mounting bracket width is 1'/ in.(38 mm). For complete dimensional information,see CAPS submittal drawings. *Note:Amp and Watt draw is approximate and may vary based on motor manufacturer.Below performance is for 220-240V. Model ControlMax CFM/Static Pressure in Inches of wg (50 Hertz Motor) Voltage RPM Amps* Input 0.000 0.050 0.100 0.125 0.150 0.250 0.375 0.500 0.625 Watts' CSP-A110 950 0.31 51 CFM 124 116 112 110 109 102 77 Sones 1.1 1.1 1.1 1.1 1.1 1.3 1.3 CSP-A190 1400 0.55 100 CFM 215 202 198 180 159 121 Sones 2.3 2.0 2.2 2.7 2.9 3.0 CSP-A390 1350 0.67 144 CFM 412 400 397 382 363 339 324 309 Sones 2.8 2.7 2.8 3.2 3.7 4.7 5.5 6.5 850 0.86 55 CFM 428 393 358 338 313 238 Soros 0.8 0.7 0.6 0.5 0.5 0.3 CSP-A51 0-VG 1275 2.40 160 CFM 621 605 590 583 572 540 479 414 328 Sores 1.5 1.5 1.4 1.4 1.4 1.3 1.2 1.5 1.7 6 1275 1.83 110 CFM 625 598 570 558 531 504 450 402 CSP-A700-VG Sones <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 0.8 10 1450 3.53 216 CFM 895 876 857 848 826 803 760 725 Songs 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 925 1.08 68 CFM 470 443 415 405 384 322 Sones 0.6 0.5 0.4 0.4 0.4 0.4 CSP-A71 0-VG GEM 730 715 699 690 681 654 622 574 514 1450 3.51 236 Sones 2.2 2.2 2.1 2.1 2.1 2.0 1.9 2.1 2.4 CSP-A780 1334 1.89 405 CFM 685 656 648 609 562 520 481 Sones 5.0 4.9 4.8 4.7 4.6 4.74.9 CSP-A1050 950 3.33 455 GEM 1079 1031 982 957 934 841 655 Sones 6.3 6.3 6.0 5.9 5.9 6.0 5.5 6 1050 1.90 115 CFM 805 780 754 741 715 689 642 597 CSP-A1 050-VG Sones <0.3 <0.3 <0.3 <0.3 0.4 0.4 0.5 1.0 10 1225 3.85 241 CFM 1131 1118 1105 1092 1070 1047 998 900 Scnes 1.0 1.0 0.9 0.9 1.0 1.0 1.2 1.3 CSP-A155D 1340 4.16 830 CFM 1391 1326 1311 1240 1171 1098 1019 929 Sones 7.5 7.4 7.4 7.3 7.4 7.3 7.3 7.2 CSP-B110 950 0.57 80 CFM 103 102 100 99 99 98 97 96 93 Sates 2.0 1.9 2.0 2.1 2.1 2.3 2.6 2.7 3.1 CSP-B150 1050 0.85 129 CFM 151 150 149 149 149 148 148 145 142 Soles 2.5 2.7 2.7 2.7 2.7 2.9 3.1 3.4 3.6 CSP-B200 1100 1.1 173 CFM 186 185 184 183 183 182 180 178 175 Soles 3.4 3.7 3.6 3.7 3.7 4.0 4.1 4.1 4.3 1 19 r a --, Accessories H :.U'a in Air 42:* ` Wheel Options SP-B Replacement Power Packs Greenheck's ceiling and cabinet fans (models SP Save installation and down time by replacing the entire and CSP) deliver high performance from a forward- power pack instead of individual components. Available curved wheel. The forward-curved wheel design offers as a replacement part on both high-efficiency and low sound. Fan wheels are all current and previous constructed of polypropylene or steel as standard, and SP-B models. 11 most models offer an aluminum wheel option. e,,,. — • Level A models utilize steel or polypropylene (standard)wheel construction depending on size. • Level B and L models are standard with a polypropylene wheel. Polypropylene ���' Contractor 4 Packs Save installation time and labor by installing the housing first, then installing the internal components ;)+ after the sheetrocking, plastering and finishing is done. ,^`` ��!- Housings are packaged in one box, power assemblies ,\. and grilles are packaged in another box. Components are shipped to coincide with the phase of your project. Ott el Aluminum (Model SP-B and SP-L series). R 4_ k t...„. , ;$4 t % : ' -' . r • 20 111 II Accessories , ,ECK ,ii Value in Ain,' Grille Options Lighted Grille Options Designer(Standard) Greenheck's fan and light combinations include either a Available in white prismatic or a frosted lens with LED lamp. Our unique polystyrene finish, with light box is manufactured with a reflective material to optional motion humidity increase the light given off by the LED lamp. UL Listed or combination sensors. for above bathtub and showers with GFCI branch All optional sensors have protected circuit. time delay functionality as standard. Model SP-A, sizes 50- 390 Available on A50-A390 and B50-B200.No grille Model SP-B, sizes 50 -200 mounted sensors available on the SP-L50 and SP-L80. Note: When selecting a lighted grille it will add height to Aluminum the fan assembly. See CAPS drawings for exact values. White enamel finish standard for ` giff7 models A410-A1550. Optional for models A50-A390 and j Prismatic Lens = �- B50-B200. " " The prismatic lens design provides approximately 25% more light than a I l Stainless Steel traditional frosted lens.The lens may be + Polished stainless steel finish optional easily removed to replace light bulbs. • fir.. for models A50-A390 and B50-B200. Frosted Lens The frosted lens option is a traditional - Decorative r design which lets approximately 80% (II White plastic finish, with or without L of light through the lens.The lens may light, motion detector with time delay. ' j be easily removed to replace light Optional for models A50-A390 and bulbs. B50-B200. " `� - Note:Our LED light bulbs are ENERGY STAR®certified. Not all fan/lighted grille options are Architectural Grilles ENERGY STAR®certified. See CAPS for availability. Aluminum, powder coated paint. tfi'-- L.1! Available on A50-A390 and = -1 LED B50-200. =' : . iL=a L • GU24 Base • 85% more efficient than 0* • 25,000 hour life incandescent • Reflective light box Custom Molded polystyrene available in an array of colors. Includes all the same accessory options as the standard grilles. For more information on the many ways this grille option can be used, please contact your Greenheck representative. Customized Grille Lens Lenses can be customized with formed shapes , �•R or logos. Contact your Greenheck representative for details. �F y 21 Accessories • _H ■ ,, - in Air ' "'‘ Filters Hanging Vibration Isolators Fans used in most applications will collect airborne dirt Vibration isolator kits are available for suspended on wheels and motors over time, even where air is not installations. Kits include all hardware necessary to excessively dirty.Accumulations of dirt on the fan wheel mount one unit, with the exception of 1/4-20 threaded will sharply reduce performance and cause imbalance, rod to be supplied by others. Fan mounting brackets Dirt buildup on the motor can cause it to overheat.All of include prepunched these conditions will shorten the life of the fan.To help mounting holes for reduce this accumulation, washable aluminum mesh ease of installation. A B filters are available to trap dirt before it enters the fan. These filters should be regularly cleaned to maintain 114-20�" performance.The Filter Loss Chart below shows the support ' Illoo••• effect the filter will have on performance.To determine rod by others iliti. the added resistance, divide the desired cfm by the filter area(ft2).This will I give ft/min. Use this with the filter loss chart to get the o - added resistance. _ \ 1 Filters reduce Mesh ` sound levels, in Filter \\\` \ addition to reducing -,�\\������������ ��� Unit Size A B dirt accumulations ��������� \\\\\\\\\ on the motor and SP B50-B200 4/(114) 15%(397) Wheel. Grille A50-A190 5/(140) 15(381) _ -.._... A200-A390 6%(171) 15%(400) Filter Loss Chart A410,A510,A510-VG,A710,A710-VG,A780 9V(235) 1934(502) Filter Model A700,A700-VG 51(140) 25%(645) Filter SP Model Designer *Metal Area(ft2) A900,A1050,A1050-VG,A1410,A1550 91/4(235) 251,6(648) Grille Grille I SP-A50-A190 F-200 F-210 0.739 A1750,A2150 9Y(235) 363/4(933) SP-B50-B200,A200 -A390 F-200 F-220 0.911 A3600 9%<(235) 47/(1200) ;,SP-A410-A510, SP-A510-VG, NA F-250 1.518 All dimensions shown in inches(millimeters). l SP-A710-A780,SP-A710-VG SP-A900-A1550, NA F-260 , 2.078 SP-A1050-VG Model RDC - Round Duct Connector *Aluminum or Stainless Steel Grille. • Replaces the standard square discharge RDC-8 Transition Duct Reducer duct connector and damper • Durable plastic construction o vm • Uses existing nm mounting holes01 \ • RDC-6 includes ,� i '.' a dampers . 3 i1s pal 4s15 (polypropylene construction) • RDC-8 does not include a damper(galvanized Model For use with sizes: construction) 473324* B50-B200 A50-A90 Model Use with sizes: 1 Diameter 6x4 Reducer A110-A190 --- ---- --- ---- --- RDC-6 A110-A190 1: 6(152) 481734 L50,L80 A200-A510 4x3 Reducer RDC-8 A510-VG,A710-VG 8(203) All dimensions shown in inches(millimeters). — - -- ------- - —-- -- - - *Used in conjunction with RDC-6 for SP model sizes A110 thru A190 All dimensions shown in inches(millimeters). 22 Accessories iiii,` .. K `t: Value i Ceiling Radiation Damper D---"----, The National Fire Protection Association (NFPA) RJ-4 and RJ-6x9 E {'�� C\� Standard 90A requires openings in fire rated ceiling j I assemblies to be protected by appropriately rated ceiling radiation dampers.As a result, many local L\ codes require fans installed in fire rated ceilings to be D C \A protected by dampers which are insulated against both \ B heat and flame. �,/ Greenheck's ceiling radiation dampers are also Warnock Hersey Listed to go into a one hour E RJ-1 Ox10 combustible(wood) installation. Greenheck's UUcUL B Classified ceiling radiation dampers are rated for three A hours of fire resistance in a steel/concrete installation. Model RJ - Pitched Roof Cap Model SP-A • Steel construction with black enamel finish SP-A Fan • Integral flashing flange Hanging • Built-in birdscreen and damper ;:.. Vibration __. __. . ,.____ - -, Isolation Model Use for sizes: A B C D E Throat .","` Ceiling 80,80L,C50, 11 9% 8'h 5%a 41/2 4(102) Radiation RJ-4 B50-B80,L50,L80 (279) (235) (210) (135) (114) diameter Damper — -- --- _. f 110,100L, 18'/ 14'/< 14% 10'/e 6'/z 6 x 9 3 in. FRated ire RJ-6x9 B90-A390 f A50-A390 (476) (362) (368) (264) (165) (152x 2291 Ceiling I - Ax6 Grille A410-A1050 Model SP-B RJ- A510-VG, 181/2 271/2 15% 23% 91/2 10 x 10 SP-B Fan Alldimensions [ 0 -V shOWn'o inches(mllh(mefe/5)�) (600) (241) (254x254)1 Hanging - ,-_, "'Vibration a�y,\ .. �,_' Isolation Ceiling MBA Radiation 10 11.125 Damper (254 (283) } /Fire 3 in. /� Rated L r,: e, Ceiling 3.5(89)-- Axe 'I Grille 2.875(73)' 9.375 SP Model CRD Length(A) Width(B) Height UL W.H. 6.5(165) " (238) A50-A190 310 13'/z 3 31 D 310 1.625(42)— (283) (343) (283) (76) 310E B50-B200 14% 12% 3 320 3.375(so //„ A200-A390 320 (365) (311) (76) 320L 320 //�j\` A410-A510 / 11.25 A510-VG, 18'/c 14' 3 5.125 350 a/a 350 350 (292) A710-A780 (468) (379) (76) (139) A710-VG �._ All dimensions shown in inches(millimeters). A700,A700-VG 700 (6 4J 377) n6) 700 NA Model EL-10x3 - J A900-A1550, 2a'rs ,a's 3 360 360 Elbow Discharge with Grille A1050-VG 360 ', (614) (379) (76) g All dimensions shown in inches(millimeters).Add an"L"to all CRD models if • Designed for installation under roof eaves fan&light combo is used.'CRD is approximately 1/4 inch(6 mm)larger than housing dimension.(See Installation,Operation and Maintenance Manual). • Black epoxy finish (elbow and grille) 4`,pssip, •• Built-in damper 0 U5 • SP and CSP sizes 50-290 C (M) US lntertek 23 Electrical Accessories a E` ff.ECit :Ct:1' V.,luc.r)Ar ? . Dehumidistat Speed Controls Dehumidistats are available as a wall Speed controls may be used on model mount switch or integrated to the fan. SP and CSP fans for manual adjustment Each sensor automatically detects of the fan's performance(for final system excess humidity to help control i) n balancing)or to control the fan's output in condensation. confined spaces, such as conference or Wall switch: „ meeting rooms. The fan can be adjusted to 60% of design airflow with a speed • Rated for 120V, 3A, 1/6 HP control.This reduction in airflow and fan • UL Listed - -- speed is also accompanied by a reduction Integrated switch to fan: in noise level. Solid state speed • Available on 115V controls are available fora range of - SP-A50 thru SP-A390 applications up to 15 amps. Speed -SP-B50 thru SP-B200 controls can be used to operate more than one fan if the combined total amperage of the fans does not exceed the control rating. Internal Mounting SPEED CONTROL INTERNAL AND/OR EXTERNAL MOUNTING OPTIONS Model FAN SIZES Voltage Rating Amp Rating 50 70 80 90 1110 125 150T190 200 250 290 390 410 510 700 710 780 900'1050',14101550 1750 2150 3600 BWSSC 115-127V VE I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E i/E NA NA NA NA NA NA 6 Amp 10WSSC 115-127V EEEEE EEEEEEEEEEEEEEEEEE NA 10 Amp 15WSSC 115-127V E E E E E E E E E E E E E E E E E E E E E E E NA 15 Amp 5W240 220-240V NA NA NA *I/E I/E NA I/E I/E *I/E NA I/E I/E NA I/E NA NA I/E NA I/E NA I/E NA NA NA 5 Amp BWSSC 220-240V NA NA NA *E E NA E E 'E NA E E NA E NA NA E NA E NA E NA j NA NA 8 Amp 5W277 227V NA NA NA NA I/E I/E I/E I/E *l/E NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 5 Amp E=External mounted only I/E=Available Internal and External Mounted KEY: *Only available on the B-series(A-series is not available) NA=Not available NOTES: Speed controllers are not available for 208V applications. SP-050 speed controller is shipped loose only. All speed controller options listed in table are UL Listed. Handy box sizes are 2x4 for all options above except 10WSSC and 15WSSC,which are 4x4. Speed controller is not compatible with SP-A50-90-VG and SP-A90-130-VG Thermostat Reverse Acting Adjustable for temperature ranges between • P 9 UL Approved 30°F to 110°F (-1°C to 43°C) 120V, 16 amp • CSA Certified Cooling • 120V, 22 Amps When the temperature in the space rises above the set point of 50°F to 90°F(10°C to 32°C)the contacts close and the thermostat will signal the fan to come on in order to exhaust air from the space. 24 Electrical Accessories F ,, C, Switches Motion Detectors Switches may be used on model SP and Motion detectors may be used CSP fans to enable manual control of your i with SP and CSP fans or fan 0 fan or fan and light combination. and light combinations. Motion detectors use a passive infrared 1 Function 1 y motion detector to automatically Single pole rocker switch assembly turn the fan on when a change • Rated for 120-277V, 15A in motion is sensed.They have • UL Listed a viewing area of 180 degrees, however they must be placed in 1 Function with Pilot Light MP, the line-of-sight. Single pole light combination switch �, ,. — -, Grille Mounted assembly } r Available on models up through r � • Rated for 120V, 15A size SP-A390 and SP-B200. PA x iz , ..rmriiiiimm • UL Listed • Rated for 115V a _ r 2 Function „, ,, • UL Listed Two single pole combination switch Wall Mounted assembly For use on fan or lights. Available ----7w„` • Rated for 120V, 15A shipped loose. -- --� • UL Listed • Rated for 115V F • UL Listed Time Delay Switch • Requires 2x4 handy box • Time delay can be set for Time delay switches save energy by 30 seconds to 30 minutes in automatically turning off equipment.They .� 5 minute increments may be used with SP and CSP fans or fan and light combinations for extended 4- operating time of fan.Time delay switches Firestat act in the same manner as a standard • 120V, 8 Amp to 120V, switch, however,there is a delay of 10 to 60 minutes after the fan has been turned off. 4 Amp capacities • Max element temperature of 1 Minimum Ventilation Control 350°F (177°C) This control contains a microprocessor • Type II-5 inch insertion that monitors the operation of the fan to • Type Ill - 111/2 inch insertion make sure that the space is receiving the ■ correct amount of ventilation per ASHRAE 62.2 Transformers • 120V, 2.5A "-"'"""' *' Transformers are available for i • UL Listed :- applications requiring voltage ' reduction. Selection is based onFIM motor amperage. All transformers "" are shipped loose. See performance k pages for motor amp ratings. Models Voltage Ratings Amp Ratings T 2 0 230/277V to 115 1 2.0 Amps T-4.3 230/277V to 115 4.3 Amps Note:All switch covers are standard white. - 3 i T-6.5 230/277V to 115 6.5 Amps Other colors available upon request. T 8.6 230/27N to 115 1 8.6 Amps I 25 Discharge Accessories • in Air Model WC - Hooded Wall Cap Model WC - Hooded Wall Cap (Round Connection) (Square or Rectangular Connections) • Aluminum construction - aluminum finish • Steel construction with black enamel finish • For outside wall applications • For outside wall applications • Built-in birdscreen (not available on WC-4) • Built-in birdscreen and damper and damper B ~G .'per Fy AC ' c It- A-.1•1111P'"1 \ ,.„._,ti E II.` -IDL =: Model Recommended A B C D E Model Recommended A BCD E F G Sizes Sizes WC-4 C50, L50, L80 6'/ 6 4 4 5 WC-10x3 50-290 5'/z 12'/< 3'/� 101/411"/a 4"/a 5 (165) (152) (101) (101) (127) (140) (324) (89) (260) (283) (108) (127) WC-6 B50-B200, 80, 80L 8 8 6 4'/ 5 WC-8x8 200-510 101/4101/4 81/4 8'/4 8'/ 6'/< 5 A50-A190, 110, 100L (203) (203) (152) (105) (127) (260) (260) (210) (210) (210) (171) (127) WC-8 A200-A510 11 11 8 51/4 3/ 101/4 20% 8/ 181/4 1814 6% 5 (279) (279) (203) (130) (89) WC-18x8 700-1550 (260) (514) (210) (464) (464) (171) (127) All dimensions shown in inches(millimeters). All dimensions shown in inches(millimeters). Model WL - Wall Louvered Discharge Model BVE - Brick Vent • Anodized aluminum grille • Designed for installation in masonry walls • Built-in damper • Anodized aluminum construction • Not recommended for exterior applications exposed • Built-in aluminum mesh insect screen to severe weather conditions. An external wall louver is recommended for such applications. r A---- *i e 1 Model Recommended A B C D E Model Recommended A B C Sizes Sizes WL-10x3 50-290 12 5'/4 10 Tia 3'b BVE808 50-290 8'/o 7% 4 (305) (133) (254) (197) (89) (206) (197) (102) WL-18x6 390-1550 19'/" 8 18 9 6 BVE128 390-510 12 7% 4 (502) (203) (457) (229) (152) (305) (197) (102) All dimensions shown in inches(millimeters). BVE157 700-1050 155/ 73/4 4 (397) (197) (102) All dimensions shown in inches(millimeters). 26 r" Discharge Accessories .1 ;. - 'tT •,:vj aiue it .`ir. t Model RCC-7 - Curb Cap Model GRS - Curb Cap • Weathertight aluminum f B •All aluminum exterior construction construction • Galvanized steel internal B • Integral birdscreen �D supports • Built-in curb cap Dia. D I • Integral birdscreen D-(f • Requires roof curb A I —F(38 • Built-in curb capI Dia. I�445 • Requires roof curb A J ( ) For all Throat For all Throat Model sizes: A B C D Dia. Model sizes: A B C D Dia. RCC-7 50-390 15(381) 12(305) 10(254) 63/8(162) 7(178) GRS-10 410-710 19(483) 201/4(521) 73/4(197) 2(51) 101/4(260) All dimensions shown in inches(millimeters). GRS-12 780-1050 22(559) 29(737) 10(254) 312(89) 1214(311) GRS-16 1410-2150 26(660) 29(737) 11 (279) 41/4(108) 165/,5(414) GR5-20 3600 30(762) 35%%(902)111/4(286) 33/4(95) 20 10(516) 1 Model GRSF - Flashing Flange All dimensions shown in inches(millimeters). • All aluminum exterior construction B Model RFC-7 - Flashing Flange • Galvanized steel internal • Weathertight aluminum B supports r,fC construction r -- • Integral birdscreen ✓1 i • Integral birdscreen J Dia. -TC • Built-in flashing flange A • Built-in flashing flange 1 D —Dia.' ` Model For all A B C D Throat sizes: Dia. �q .� GRSF-10 410-710 23(584) 201/2(521) 733A(197) 2(51) 101/4(260) GRSF-12 780-1050 26(660) 29(73n 10(254) 3'/>(89) 12%(311). Model For all A ) B -- _...C D Throat -- --- sizes: ! Dia. GRSF-16 1410-2150 30(754 29(737) 11(279) 4'/4(108) 165As(414), 457)1 12 ) 10 254)1 3 (162) 7(178) j GRSF-20 3600 34(864) 35'h(902) 11944(286) 3%4(35) 20%(516)' All dimensions shown in (inches(millimeters). 6/e All dimensions shown in inches(millimeters). Accessory Pressure Drops 3o I I _ 1 The rt o the right can be th all of the discharge e t accessories shown and pages 23, 26 and 27. zo wL-1ex6 9P 9 . I Specific pressure drop values for these accessories ._..RJ-10x10 must be included in total system calculations for proper + Y P P 8,o BVE-157, fan selection. . 8 1 WC-18x8 6 7 � I WC-8x8 m WC-8 s 5 WC-6, RJ-6x9, 4 EL-10x3, WL-10x3, 3 _ ! BVE-806: - - RFC-7, 1 RCC-7 ' I .01 .02 .03 .04.05.06.07 Oa 0910 Pressure Drop(Inches wg( Above accessories tested with 4 feet of inlet duct 27 Specifications Vari-Green® m _ inAic ,i/b Vari-Green Control - Indoor Air Quality- War Temperature / Humidity fit/ s Control to be a packaged indoor air quality control 11 designed to regulate fan speed based on level of temperature and/or relative humidity in a space. Control • { shall include a Proportional Integral Derivative(PID) *1` » feedback loop and shall have labeled terminal strips for easy wiring. Fan shall be direct drive including an electronic commutation(EC)Vari-Green Motor. Control package shall be Vari-Green Indoor Air Quality— Temperature/Humidity Control. Vari-Green Motor Motor to be an electronic commutation (EC) motor Vari-Green Control - Indoor Air Quality— specifically designed for fan applications. AC VOC (Volatile Organic Compound) induction type motors are not acceptable. Examples Control to be a packaged indoor air quality control of unacceptable motors are: Shaded Pole, Permanent designed to regulate fan speed based on level of Split Capacitor(PSC), Split Phase, Capacitor Start VOC concentration in a space. Control shall include a and 3 phase induction type motors. Motors shall be Proportional Integral Derivative(PID)feedback loop and permanently lubricated with heavy-duty ball bearings shall have labeled terminal strips for easy wiring. Fan to match the fan load and prewired to the specific shall be direct drive including an electronic commutation voltage and phase. Internal motor circuitry shall (EC)Vari-Green Motor. Control package shall be convert AC power supplied to the fan to DC power to Vari-Green Indoor Air Quality—VOC Control. operate the motor. Motor shall be speed controllable down to 20% of full speed (80% turndown). Speed Vari-Green Control - Constant Pressure shall be controlled by either a potentiometer dial Control to be a packaged constant pressure control mounted on the motor or by a 0-10 VDC signal. Motor designed to regulate fan speed based on demand. shall be a minimum of 85% efficient at all speeds. Control shall include a Proportional Integral Derivative (PID)feedback loop and shall have all components Vari-Green Control - Remote Dial prewired to labeled terminal strips for easy wiring. Remote Dial shall be a Vari-Green Control specifically System shall include the appropriate pressure tap and designed to provide 0-10 volt DC signal to Greenheck's preset pressure transducer. Fan shall be direct drive Vari-Green Motor. including an electronic commutation (EC)Vari-Green Motor. Control package shall be Vari-Green Constant Vari-Green Control - Two Speed Pressure Control. Two speed control shall be a Vari-Green Control Indoor installations shall include pressure tap specifically designed to allow the Vari-Green Motor (duct or room)and control box with integral to operate at two discrete speeds.Two speed control pressure transducer. shall include two dials that may be set at any point Outdoor installations shall include duct pressure tap, between 0 and 10 volts DC and an integral transformer pressure transducer, and control box. Control box shall capable of reducing 115/208-240 volt AC power to be prewired and in a NEMA-3R weather tight enclosure 24 volt AC power. for mounting outdoors near the fan location. LEED information Greenheck became one of the first The Vari-Green®motor significantly helps manufacturers in the Air Movement qualification efforts for the Energy and Atmosphere lir and Control industry to join the LEED/ credits and prerequisites; specifically credit one, green movement when they joined the United Optimize Energy Performance and prerequisite two, States Green Building Council (USGBC) in Minimum Energy Performance. 2005. Greenheck has been actively researching qualification requirements for our products to meet LEED credits and prerequisites. 28 a, �e p may. Vari-Green® E CK . Model Specifications s "s]n Value in AA"' • • Models SP-A5O-90-VG and SP-A9O-130-VG Ceiling mounted exhaust fans shall be of the centrifugal direct drive type.The fan housing shall be constructed of heavy-gauge galvanized steel.The housing interior shall be lined with 0.5 inch acoustical insulation.The outlet duct collar shall include a plastic backdraft damper. Outlet shall be adaptable for horizontal or vertical discharge.The designer grille for sizes SP-A50 through SP-A390 shall be constructed of high-impact polystyrene. The access for wiring shall be external.The motor disconnect shall be internal and of the plug-in type. The motor shall be mounted on vibration isolators.The fan wheel shall be of the forward-curved centrifugal type and dynamically balanced.The fan shall have a rocker switch with 3 cfm settings located internally. For the SP-A50-90-VG the settings are 50, 70, and 90 cfm. For the SP-A90-130-VG the settings are 90, 110, and 130 cfm.The fan will come preset at 70 cfm for the SP-A50-90-VG and 110 cfm for the SP-A90-130-VG. Upon installation, the switch shall be selected to the desired CFM. All fans shall bear the AMCA Certified Ratings program AMCA Sound and Air Performance seal and shall be UUcUL Listed. Ceiling or wall mount fans shall be model SP as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin. Complete specifications, in Construction Specifications Institute(CSI)format, are available on greenheck.com. Ai � y y Ig�� i gyp . 29 � x s Model Specifications / frrf ; NI - , '- ,F- -1 Model SP-80(L)-VG, SP-110(L)-VG Ceiling mounted exhaust fans shall be of the centrifugal ,. r': direct drive type with an EC motor and overload iip . protection. The fan housing shall be constructed of galvanized steel and have a low profile housing. The � outlet duct collar shall have an aluminum backdraft ✓.�• ^^' , •,.1, damper. The fan shall be capable of built-in two-speed operation with a time delay. The access for wiring shall be external. The motor disconnect shall be internal and of the plug-in type. The fan wheel shall be of the forward-curved centrifugal Models SP-A50 thru A1550 type and dynamically balanced. All fans shall bear the Ceiling mounted exhaust fans shall be of the centrifugal AMCA Certified Ratings program AMCA Sound and Air direct drive type.The fan housing shall be constructed Performance Seal and shall be UUcUL Listed. of heavy-gauge galvanized steel. The housing interior shall be lined with 0.5 inch (13 mm)acoustical insulation. Models SP-B50, B70, B80, B90, B110, B150, The outlet duct collar shall include a polypropylene and B200 backdraft damper on SP-A50- SP-A90 and a spring loaded aluminum backdraft damper on SP-A110 and Ceiling mounted exhaust fans shall be of the centrifugal larger. Outlet shall be adaptable for horizontal or vertical direct drive type. The fan housing shall be constructed discharge. The designer grille for sizes SP-A50 through of galvanized steel. The polypropylene duct collar shall SP-A390 shall be constructed of high-impact polystyrene be 6 inches(152 mm) in diameter and shall include and for sizes SP-A410 through SP-A1550,the grille a backdraft damper. The designer grille shall be shall be constructed of aluminum. Grilles shall be constructed of non-yellowing high-impact polystyrene non-yellowing. and attached to the housing with hidden attachment screws. The access for wiring shall be internal. The The access for wiring shall be external. The motor motor disconnect shall be internal and of the disconnect shall be internal and of the plug-in type. plug-in type. The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal The motor shall be mounted on vibration isolators. type and dynamically balanced. All fans shall bear the The fan wheel shall be of the forward-curved AMCA Certified Ratings program AMCA Sound and Air centrifugal type, constructed of calcium carbonate filled Performance seal and shall be UUcUL Listed. Ceiling polypropylene and dynamically balanced. All fans shall fans shall be model SP as manufactured by Greenheck bear the AMCA Certified Ratings program AMCA Sound Fan Corporation, Schofield, Wisconsin. and Air Performance Seal and shall be UUcUL Listed. Model SP-A fans with 50 hertz motors are not AMCA certified. Ceiling fans shall be model SP-B50, B70, B80, B90, B110, B150 or B200 as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin. Model SP-B fans with 50 hertz motors are not AMCA certified. 30 4 g Model Specifications r blue i Model SP-050 Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed _ of galvanized steel.The polypropylene duct collar shall be a sleeve for ease of connection to 3-inch (76 mm) and 4-inch (102 mm)round ductwork and shall include - a backdraft damper.The grille shall be constructed of non-yellowing high-impact polystyrene and attached to the housing with torsion springs. r The wheels shall be constructed of high-strength polymer.The access for wiring shall be easily accessible internally. The motor disconnect shall be internal and of the plug-in type. All fans shall bear the AMCA Certified Ratings program AMCA Sound and Air Models CSP-A110 thru A3600 Performance seal. Model SP-050 shall be UL Listed. Duct mounted exhaust, supply or return air fans shall Fans shall be model SP-050 as supplied by Greenheck be of the centrifugal direct drive type.The fan housing Fan Corporation, Schofield, Wisconsin. shall be constructed of heavy-gauge galvanized steel. Model SP-C fans with 50 hertz motors are not AMCA certified. The housing interior shall be lined with 0.5 inch (13 mm) acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper and shall be adaptable for horizontal or vertical discharge.The access for wiring shall be external. The motor disconnect shall be .40011111W " P internal and of the plug-in type. The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal type and dynamically balanced.All fans shall bear the AMCA Certified Ratings program AMCA Model SP-L50 and SP-L80 Air Performance Seal and shall be UUcUL Listed. Ceiling fans shall be model CSP as manufactured by Wall or ceiling mounted exhaust fans shall be of the Greenheck Fan Corporation, Schofield, Wisconsin. centrifugal direct drive type.The fan housing shall be constructed of galvanized steel.The galvanized duct Model CSP-A fans with 50 hertz motors are not AMCA certified. collar shall be sized to fit a 4-inch diameter duct and Models CSP-B110, B150 and B200 shall include a backdraft damper.The grille shall be constructed of non-yellowing high-impact polystyrene Duct mounted exhaust, supply or return air fans and attached to the housing with hidden attachment shall be of the centrifugal direct drive type. The fan screws. The access for wiring shall be internal. The housing shall be constructed of galvanized steel. The motor disconnect shall be internal and of the plug-in polypropylene duct collar shall be 6 inch (152 mm) in type. diameter to accept 6-inch (152 mm) round ductwork The fan wheel shall be of the forward curved and shall include a backdraft damper. The access for centrifugal type, constructed of calcium carbonate filled wiring shall be internal. The motor disconnect shall be polypropylene and dynamically balanced.All fans shall internal and of the plug-in type. bear the AMCA Certified Ratings program AMCA Sound The motor shall be mounted on vibration isolators. and Air Performance Seal, shall be UUcUL Listed and The fan wheel shall be of the forward-curved shall be Energy Star 4.0 qualified. Wall or ceiling mount centrifugal type, constructed of calcium carbonate fans shall be model SP-L50 or L80 as manufactured by filled polypropylene and dynamically balanced. All Greenheck Fan Corporation, Schofield, Wisconsin. fans shall bear the AMCA Certified Ratings program AMCA Air Performance Seal and shall be UUcUL Listed. Ceiling fans shall be model CSP-B110, B150 or B200 as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin. Model CSP-B fans with 50 hertz motors are not AMCA certified. 31 q ,a. Design and Selection Support µ° F , •Enjoy Greenheck's extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. r Our Quick Delivery Program ensures shipment of our in-stock products D within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3-5-10-15 or 25-day production cycles, depending upon their complexity. Greenheck's free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and al _ efficiently select the right products for the challenge at hand. A Greenheck has been Green for a long time! Our energy-saving products { NOr and ongoing corporate commitment to sustainability can help you qualify creenner,k for LEED credits. GREEN �e Our 3D service allows you to download, at no charge, easy-to-use � +iri AutoDese Revit® 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com �, ii 201 lt a�� ` Building Value in Air >< 41 Greenheck delivers value top quality,innovative air- And building owners and C to mechanical engineers by related equipment.We offer occupants value the energy helping them solve virtually extra value to contractors efficiency.low maintenance any air quality challenges by providing easy-to-install, and quiet dependable operation it., 4 their clients face with a competitively priced,reliable they experience long after the -- comprehensive selection of products that arrive on time. construction project ends. Our Commitment �a,3tLo/k � Iri ,, � a As a result of our commitment to continuous improvement, Greenheck reserves the right to change N i n specifications without notice. Lai Product warranties can be found online at Greenheck.com,either on the specific product page or MfMBE,' Pia n the literature section of the website at Greenheck.com/Resources/Library/Literature. Prepared to Support t Green Building Efforts IWO / GREENHECK _ Building Value in Air. 00F&V 1013 R152-2019 SP P.O.Box 410• Schofield, WI 544 76-04 10•Phone(715)359-6171 •greenheck.com Copyright©2019 Greenheck Fan Corp. r Ra 1 OPERATING MAINTENANCE REZNOR® INSTRUCTIONS INSTRUCTIONS Rcznor LLC O'Fallon,MO USA 63368-Tel.:1 800 695-1901 The heater must be properly installed before it is used. The heater motor is permanently lubricated. www.ReznorHVAC.com 02014 Reznor,LLC.All rights reserved.All other trademarks are the DATER OPERATION Occasional cleaning of the inlet grille will prevent clogging. property of their respective organizations. Use a vacuum with a brush attachment. INSTRUCTIONS Startup Cleaning should be done while the heater is disconnectedfrom EGEB Model(10:1 kW to 20 kW) the main service panel.Wait until the housing and heating On a call for heat from either the remote thermostat or the unit elements cool before performing maintenance. • mounted thermostat the elements and fan will be energized. e WARNING When the thermostat is satisfiedAny other servicing should be performed by a qualified the elements wilt be deenergized. technician. The fan will continue to run until the residual heat is removed When using electrical appliances,basic precautions should always be from the heater.Then the fan will stop. taken to reduce the risk of fire,electrical shock and injury,including the following: Automatic Reset Thermal Hieh Limit Read carefully these instructions before installation,operation of the The heater has an automatic reset thermal high limit that will deener- heater Failure to adhere to the instructions could result in fire,electric gize the heating elements if the interior temperatures of heater exceed shock,serious personal injury,and death or property damage.Review its setting.The limit will automatically reset when the heater interior frequently for continuing safe operation and instruction of future users,if necessary. temperatures fall below its setting. IMPORTANT INSTRUCTIONS - Read all instructions before installing or using this heater. - This heater is hot when in use.To avoid bums,do not let bare skin touch hot surfaces. Keep combustible materials, like furniture, pillows, bedding. papers, clothes, and curtains at least 36 in. (915 ram)from the front of the heater and away from the sides and • MT. - Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended. - Do not operate any heater after it malfunctions.Disconnect power at service panel and have heater inspected by a reputable electrician before reusing. - To disconnect heater, turn off power to heater circuit at main disconnect panel. - Do not use outdoors. - Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electrical shock or fire,or damage the heater. - To prevent a possible fire,do not block air intakes or exhaust in any way whatsoever. - A heater has hot and arcing or sparking parts inside.Do not use it in areas where gasoline,paint or flammable liquids are used or stored. - Use this heater only as described in this manual.Any other use not recommended by the manufacturer may cause fire,electrical shock, or injury. - The thermostat should not be considered an infallible device in cases where maintaining a temperature is considered critical. In these particular cases,it is imperative to add a monitoring system to avoid the consequences of a thermostat failure. - This heater is not approved for use in corrosive atmospheres,wet or very humid locations such as marine,green house or chemical storage areas. SAVE THESE INSTRUCTIONS INS263-201001-07 REZ INSTRUCTIONS INSTRUCTIONS rLLC UTILSA ON TTI O'Fallon,MO USA 63368-Tel.:1 800 695-1901 www.ReznorHVAC.com Laappareil doit etre install¢correctement avant de l'utiliser. Le moteur de l'appareil de chauffage est lubrifie de maniere t 2014 Reznor,LLC.All rights reserved.All other trademarks are the property perruanente. of their respective organizations. FONCTIONNEMENT DE L'APPAREIL Nettoyer la grille d'entree d'air de temps a autre pour Eviler INSTRUCTIONS Mise en marche I'encrassement.Utiliser un aspiratem muni d'une brosse. EGEB Model(10.1 kW to 20 kW) Des que le thermostat mural ou le thermostat integre a l'appareil Le nettoyage doit etre fait apres avoir coupe l'alimentation • A AVERTISSEMENT © envoi one demand¢de chauffage,Its elements commencent a electrique au panneau d'alimentetion principal.Attendre chauffer el le ventilateur demarre. que le bolder et les elements de l'appareil aient refroidi avant de procederal'entretien. Lorsque la temperature desiree est atteinte au thermostat,lee Lors de l'utilisation d'appareils electriques,it est important de respecter les elements cement de chauffer. Un lechnicien qualifie pout accomplir tout autre service. regles de secmite de base,notamment les consigns suivantes,pour reduire les risques d'incendie,de oboe electrique et de blessure. Le ventilateur continue de fonetionnerjusqu'a cc que la chaleur residuelle snit evacuee de l'appareil.Le ventilateur s'eteint ensuite Lire attentivement ces instructions avant de proceder a ('installation ou de lui-memo. !'utilisation de cot apparel!.Ne pas respecter ces instructions pout entminer on incendie,une electrocution,des blessures graves,la mort ou des digits materiels. Protection thermique a reenclenchement Consultez-les regulierement pour assurer un bon fonctionnement securitaire et renseigner les tutors ulilisateurs,le cas echeant. automatique INSTRUCTIONS L'appareil est muni dune protection thermique a reenclenchement IMPORTANTE S temperature automatique qui¢feint les elements chauffants loreque la temper interne de l'appareil&passe sa valeur de reglage. - Lire attentivement toutes les instructions avant d'installcr ou d'utiliser cct disposititremei l'appareil de chauffage en march¢des quo la appareiL temperature interne a baisse sous sa valeur de reglage. - La temperature de surface du bonier de l'appareil peut etre¢levee lorsqu'il • fonctionne.Pour prevenir les brtllures,eviter de toucher les surfaces chaudes du boitier avec la peau.Garden les produits combustibles tels que mobitiers, coussins,Mertes,joumaux,vetements el rideaux a une distance d'au moires • 36 po(915 rum)du devant de l'appareil et eloignes de farrier¢et des cotes. - Toujours prendre d'extremes precautions lorsqu'un apparcil de chauffage est utilise a proximite d'enfants ou de personnes handicapees,ou lorsqu'il est laisse en fonction sans surveillance. - Ne pas utiliser cot appareil de chauffage apres un mauvais fonctionnement. I Cooper]'alimentation electrique au panneau d'alimentation et false inspector l'appareil par un technicicn qualifie avant de reutiliser. - Pour debrancher l'appareil,couper]'alimentation electrique sun le perinea, d'alimentation principal. • i - Ne pas utiliser a l'extericur. - Ne pas inserer de corps etmngers a 1'interieur des bombes de ventilation ou de sorties d'air de l'appareil,sous risque de provoquer un incendic ou un court-circuit,ou d'endomrnager l'appareil. - Pour prevenir les risques d'incendie,ne pas bloquer les entrées et les sorties d'air do l'appareil. - Certaines composantes de l'appareil peuvent etre chaudes et produire des arcs electriques et des etincetles.Ne pas utiliser dans un lieu on Ion utilise ou entrepose de]'essence,de la peinture ou tout autre liquide inflammable. • - Utiliser l'appareil confonnement aux instructions de ce manuel. Toute utilisation autre que cellos que recommandent le fabricant represente un danger d'incendie,de choc electrique ou de blessures. - Lc thermostat ne doit pas etre considers comma un dispositif infaillible dans Its cas on le maintien d'une temperature est jug¢critique.Dans ces cas perilculiers,it est imperatif d'ajouter en systeme de surveillance stun d'eviter les consequences d'une defaillence du thermostat. - Cetapparciln'apes ate approuve pouruneutilisation dans des environnements I corrosifs,mouilles ou lilt humides tels que les milieux matins,les serres et les sires d'entteposage de produits chimiques. CONSERVER CES INSTRUCTIONS INS263-201001-07