Loading...
Report (3) HD Fowler Note: North Duplex Pump Lift Station TECHNICAL BROCHURE B3888D4 • FEATURES Impeller: Cast iron,two vane semi-open, non-clog with pump-out couLo$ vanes for mechanical seal protection.Balanced for smooth operation. Silicon bronze impeller available as an option. SIw..Pump ® Casing: Heavy duty gray cast iron,ASTM A48,Class 30.Volute type casing with 4", 125#,ANSI flanged, horizontal discharge.Compatible with A10-40 cast iron or Al 0-40B cast iron and brass(non-sparking) guide rail assembly. Dual Mechanical Seals: Silicon carbide vs.silicon carbide outer seal and ceramic vs.carbon inner seal,stainless steel metal parts, BUNA-N elastomers. Upper and lower shaft seals are positioned independently and are separated by an oil-filled chamber. Shaft: 300 series stainless steel keyed design. Fasteners: 300 series stainless steel. Capable of running dry temporarily without damage to seals or motor. WS_ D4 Series Model 3888D4 SUBMERSIBLE SEWAGE PUMPS 4 GOULDS a xylem brand "D Fowler Nx North Duplex Goulds Water Technology Wastewate Pump Lift Station APPLICATIONS Three Phase: Used in a variety of residential,commercial and • 1.5 -7.5 HP; 200,230,460 and 575 volts industrial applications such as: • Class 10 overload protection must be provided in • Sewage systems, Flood and Pollution Control, control panel Dewatering/Effluent, Farms, Hospitals,Trailer Courts, MOTORS Motels • Fully submerged in oil-filled chamber: High grade SPECIFICATIONS turbine oil surrounds motor for more efficient heat Pump: dissipation, permanent lubrication of bearings and • Maximum solid size: 3" mechanical seal for complete protection against • Discharge size:4", 125#ANSI flange outside environment. • Maximum capacity: 620 GPM • Class F insulation • Maximum total head: 60 feet • Designed for Continuous Operation: Pump ratings • 300 Series stainess steel fasteners are within the motor manufacturer's recommended • 20' Power cord working limits and can be operated continuously • Standard silicon carbide/silicon carbide outer seal without damage when fully submerged. • Bearings: Upper and lower heavy duty ball bearing Motor: construction for precision positioning of parts and • Maximum ambient temperature: 104°F(40°C) to carry thrust loads. continuous duty, 140°F(60°C)intermittent duty • Rated for continuous duty when fully submerged • Power Cable: Severe duty rated,oil and water • Insulation: Class F resistant.Epoxy seal on motor end provides secondary moisture barrier in case of outer •60 Hertz jacket damage and to prevent oil wicking.20 foot •Single row ball bearings standard with optional lengths available. • 300 Series stainless steel keyed shaft • 0-ring:Assures positive sealing against Single Phase: contaminants and oil leakage. • 1.5 -5 HP; 208 and 230 volts AGENCY LISTINGS • Built-in thermal overloads with automatic reset d d • Built-in capacitors Sp® ByTeste CanadiantoUL Stan778darands AssociationCSA22.2 108 Standards c us File#LR38549 MODEL AND MOTOR INFORMATION Order No. HP Phase Vohs RPM Impeller Maximum L.R. KVA Power F.L.Motor Resistance Wt. Dia.(in.) Amps Amps Code Cable Efficiency% Start Line-Line fibs.) WS1518D4M 208 17.2 50.8 B 80 1.1 0.9 WS1512D4M' 1 230 14.7 29.5 E 14/3 70 1.4 1.8 WS1538D4M 200 11.5 40.9 H 81 1.7 1.5 1750 5.63 195 WS1532D4M 230 10.0 40.0 F 83 2.3 WS1534D4M 3 460 5.0 20.0 F 14/4 83 NA 9.3 W5153704M 575 4.0 14.4 H 74 14.8 WS1518D4 208 17.2 50.8 B 80 1.1 0.9 WS1512D4 1 230 14.7 29.5 E 14/3 70 1.4 1.8 WS1538D4 200 11.5 40.9 H 81 1.7 1.5 1750 6.25 195 W5153204 230 10.0 40.0 F 83 2.3 WS1534D4 3 460 5.0 20.0 F 14/4 83 NA 9.3 W51537D4 575 4.0 14.4 H 74 14.8 WS2018D4 208 20.3 50.8 B 80 1.1 0.9 WS2012D4 1 230 17.3 36.9 D 14/3 75 1.4 1.5 WS2038D4 200 13.3 40.9 H 81 1.7 2 1750 6.63 200 WS203204 230 11.6 40.0 F 83 2.3 WS2034D4 3 460 5.8 20.0 F 14/4 83 NA 9.3 WS2037D4 575 4.6 14.4 H 74 14.8 WS3018D4 208 25.5 50.8 B 80 1.1 0.9 WS3012D4 1 230 21.5 46.4 C 10/3 79 1.0 1.0 208 WS3038D4 200 16.6 53.8 G 10/4 85 1.3 WS3032D4- 3 230 1750 7.00 14.4 49.5 H 83 1.9 WS3034D4 3 460 7.2 24.8 H 14/4 83 NA 7.5 205 WS3037D4 575 5.8 17.3 G 78 11.6 WS5012D4 1 230 26.5 57.7 A 10/3 80 1.0 0.8 213 WS5038D4 200 19.1 73.9 F 10/4 84 0.9 W5503204 5 230 1750 7.25 16.6 63.6 E 85 1.2 WS5034D4 3 460 8.3 31.8 E 14/4 85 NA 48 210 WS5037D4 575 6.6 22.8 E 80 7.4 WS7532D4 230 23.0 105.0 G 83 0.7 WS7534D4 7.5 3 460 1750 7.69 11.5 52.5 G 10/4 83 NA 2.8 225 WS7537D4 575 9.2 42.0 E 84 4.4 PAGE 2 Fo HD Goulds Water Technology Du Northrth Duplexlexler �``' Wastewater Pump Lift Station MATERIALS OF CONSTRUCTION Item Material I — 6 No Part Name Standard Optional t 1 Impeller,non-clog 1003 1179 I 2 Casing 1003 _ 3 Shaft-keyed 300 Series SS 4 \N i 5 4 Fasteners 300 Series SS 7 3 i ._ ,, 5 Ball bearings Steel I -- ". % 6 Power cable STOW,20 feet Additinnal lengths 8 // 7 0-ring BUNA-N 1 1. Outer Mech. Metal Seal Service Rotary Stationary Elastomen Farts 8 OPT Heavy duty Silicon Tungsten BUNA-N 300 Series Carbide Carbide SS Mild 300 Series STD Silicon carbide BUNA-N PERFORMANCE RATINGS(gallons per minute) abrasives SS Material Code Engineering Standard Series No. ►WS15D4M WS15D4 WS20D4 WS30D4 W550D4 W575D4 1003 Cast iron-ASTM A48 Class 30 HP ► V/2 1%2 2 3 5' _ 7% RPM ► 1750 - - - 1179 Silicon bronze-ASTM C87600 10 300 395 15 170 320 370 - o « 20 230 300 440 520 a a 25 120 205 365 440 2 3 30 100 270 360 510 n o 35 160 275 440 F m 40 80 175 355 u. 45 85 260 50 155 55 80 METERS FEET 70 , I I ' r _ ' { I I I I ! - .� 1 i 4 !SERIES WS_D4 { I ' ' ' 1 �,_ Id SIZE 3"SOLIDS RP 1750 60 T T � 1- { —i — -- _ _ � l + r. 1 I 1 HPM VARIOUS 20- _ w F4 • , SO4 ,..� _- _. 1 1 -j , , ' 1 15- 50 '._._ , 1 ... —► 10GPM - . ._. U Q t L Z W ; 8 30 S€0Dq Q wS�SDq O 5 20 : WSJ 4. Sd M f-4 t b 10 I i � ft , 1 t 0 - 0 0 "-`50 100 150 200 250 300 350 400 450 500 550 600 U.S.GPM 0 20 40 60 80 100 120 140 m'/hr FLOW RATE PAGE 3 HD Fowler Note: North Duplex Pump Lift Station TECHNICAL BROCHURE BCP4 R12 FEATURES [r7�centriprom NEMA 4X, 30 watt,flashing red light and alarm horn-95db. Duplex NEMA 4X,fiberglass enclosure withgasketed, hinged door Weatherproof g g Panel and stainless steel hardware. Entire unit is UL and CUL listed. Single Phase Field adjustable for 115,208 or 230V, 60 Hz. 2 pump circuit breakers. Three Phase Mil Field adjustable for 208/230/460/575V,60 Hz. ,4 115V control circuit transformer. 2 adjustable motor overload protectors. E4 1-4" Heaters not required. (� Provides fully automatic operation for two pumps. Solid state pump alternator circuit displays float status for ease of installation and trouble shooting. DUPLEX NEMA 4X WEATHERPROOF PANELS SINGLE AND THREE PHASE CONTROL PANELS • Centri Pro a xylem brand HD Fowler Note: North Duplex Centri Pro Wastewater Pump Lift Station APPLICATIONS • Hinged door with lockable stainless steel latch for Superior quality duplex liquid-level controller,auto- safe operation indoors or out. matically controls alternation for two pump operation. • High-level alarm circuit includes through-door High-level alarm warning designed for a variety of mounted silence switch for manual silence of alarm sump,effluent,sewage and water transfer applica- horn. tions. •Through-door mounted alarm test switch insures SPECIFICATIONS proper operation of the alarm circuit without the need to open the panel. •Accepts single or dual power feed. •Two through-door mounted pump run lights. •2 hand-off-automatic(H-O-A)pump switches. •Top-mounted high intensity flashing red light pro- •On-off control circuit switch. vides 360°visibility. •2 oversized magnetic contactors. • Pulsating,corrosion proof alarm horn. • Numbered terminal strip-screw type. •These duplex controls are factory wired for opera- • Float Switches-Note: Please order float switches tion with three float bulbs.An easy field modification separately.We offer several types and models.See for four float bulb operation using separate"lag-on" the Float Switch bulletin for available options.The and "alarm bulbs"is provided. type selected determines the quantity needed. •Alternator selector switch allows a choice of auto- The basin depth and panel location determine the matic alternation or operation of only pump 1 or required cord length.Contact your distributor or pump 2.Typically used if one pump is down for Customer Service for additional information. maintenance. • Electronic pump alternator. • Lag pump-start delay built-in. Delays starting lag •Alternator selector switch. pump for 5 seconds if both pumps attempt to start • Lag pump start delay. simultaneously as after a power outage. • Panel can be wired for a single power feed for FEATURES pumps and control circuit or the control circuit can • be wired to a separate power supply to insure alarm Rugged, NEMA 4X construction withstands even the integrity in case of a tripped main breaker. most severe weather conditions and prevents corro- sion. •Auxiliary alarm contacts provided for remote alarm connection. • Provides fully automatic operation for two pumps. Alternates pump starting to distribute operating •Color coded wiring,screw type terminals and plug time.Provides extra pumping capacity in times of in sockets,ensure ease of field servicing. high inflow by energizing both pumps. • Field wiring diagram, panel schematic and installa- •Alternator selector toggle for maintenance on one tion instructions included. or both pumps. • Requires three float switches or with optional fourth lag float,order separately. PANEL MODEL INFORMATION SINGLE PHASE PANELS THREE PHASE PANELS ORDER NUMBER AMP/HP RANGE ORDER NUMBER AMP RANGE D10020 0-20 AMPS D31625 1.6-2.5 D12127 3 HP D32540 2.5-4.0 D12836 5 HP _ D34063 4.0-6.3 D36310 6.3 - 10 D31016 10- 16 D31620 16-20 D32025 20-25 D32232 22-32 PAGE 2 HD Fowler Note: North Duplex Ce ntri Pro Wastewater Pump Lift Station ADDITIONAL OPTIONS Code(add as required) P = Special duplex Mini CAS seal fail and high A = Guaranteed pump submergence circuit temperature circuit for use on only three phase C = 115V condensation heater 15/20GD, 15/20GX, 1 GA/2GA,GV Plus and Impact pumps.For single phase,see CentriPro D = Single phase lightning arrestor single phase grinder control panels bulletin E = Three phase lightning arrestor BCP1 PGP for standard, BCP1 PC1 P for explosion proof. G = Elapsed time meter(2)-Duplex T = 4 intrinsically safe relays in duplex panel J = Seal fail circuit(2)-Duplex YY= Duplex dry contact for seal failure interface to L = Cycle counter(2)-Duplex building management system. N = High temp.indicator with pump shutdown - ZZ= Duplex dry contact for pump running interface to Duplex building management system. When ordering options,add the appropriate code number as a suffix to the panel order number. Example...D31625CG adds a condensation heater and(2)elapsed time meters. ENCLOSURE DIMENSIONS (in inches) Single Phase A I B C D E F G 10.1 15.5 18.3 14.8 6.8 7.2 13.3 Three Phase A B C D E F G 12.1 17.5 20.3 16.8 6.8 7.2 15.3 NOTE Mounting holes are%". A O ■ O C B D v 0 O c G < F r PAGE 3 HD Fowler Note: North Duplex CentriPro Wastewater Pump Lift Station SINGLE PHASE COMPONENTS THREE PHASE COMPONENTS 1. NEMA 4X enclosure 1. NEMA 4X enclosure 2. Flashing alarm light 2. Flashing alarm light 3. Alarm horn(RB50) 3. Alarm horn(RB50) 4. Pump run light 4. Pump run light 5. Alarm silence button 5. Alarm silence button 6. Alarm test button 6. Alarm test button 7. Control power on/off switch 7. Control power on/off switch 8. H-O-A switch 8. H-O-A switch 9. Alarm reset button 9.Alarm reset button 10.Contactor(RB32) 10.Contactor(RB47) 11.Terminal strip 11.Terminal strip 12.Alternator circuit(RB75) 12.Alternator circuit(RB75) 13. Motor circuit breakers 13.Control transformer 14. Motor circuit protectors(RB52 through 57) 2 z O O O , O • •`O 0 C� 7,8 14 7,8 I 13 13 El E nnn E 10 1101 12 El CID I 11 9 El S 11 11 • •`O 0 O` jO\� ^ �O O - 0 1 O ' ' 0 r 1 3 1 3 PAGE 4 HD Fowler Note: North Duplex Centri Pro Wastewater Pump Lift Station DUPLEX SINGLE PHASE WIRING DIAGRAM - D10020 NOTE:The standard panels shown in this book are not designed to be used with pumps requiring external capacitors.See the catalog for panels with built-in capacitor packs. 25 A Si 0 0 I Q FOR 120 VOLT OPERATION USE TERMINALS(L1)AND(N) ; 1r PUMP N0.1 JUMP TERMINALS(N)AND(L2) i r — — 2 n A S2 I L7 I • OI I Q 230 VAC I I rl 2T 0 PUMP No.2 SINGLE PHASE I i 0 ° I © - //// 60HI I I O i WHITE I 1 I WA 1 I I • / CONTROL O ON-OFF zz- RUN A 230 VOLT SYSTEM BLACK O HAND :0: REQUIRES A 4 WIRE POWER SUPPLY LINE 0OFFPURPLE • 0L1,L2,N AND GND. YELLOW ()AUTO WITHOUT A NEUTRAL THE CONTROL CIRCUIT WILL NOT WORK. RUN .. •BLACK 0HAND N. O OFF BLUE ALTERNATOR SWITCH- ORANGE ()AUTO () STANDARD ON ALL DUPLEX PANELS,THIS SWITCH PROVIDES OPTIONS FORE) ALTERNATE PUMPS,USE RED ONLY PUMP 1 OR USE ONLY PUMP 2.IT IS USED WHEN A O ALTERNATOR SWITCH O TEST PUMP IS REMOVED FOR i PUMP 1 RED—L SERVICE. R1 EI ALT TEST °"—" n PUMP 2 nn SILENCE 1!R2 MUTE C 4r YE O O-1 �C YELLOW I J FOR SEPARATE 120 VAC J( ` ` ' BR RESET CONTROL POWER SUPPLY, V c ��� ��. .�. .�� RESET J7�� REMOVE JUMPER(J1)FROM OFF LEAD LAG ALARM C BROWN TERMINALS(WAND(L1). FLASHING* FLASH CONNECT 15 AMP MAX. 1[ RED PROTECTED 120 VAC SUPPLY J� �� TO TERMINALS(L1)AND(N). L1 N,r SONALERT PINK HORN WITH THE NEUTRAL OF THE i WHIT SUPPLYTO(N). H L1 N 1 2 3 4 5 6 7 8 9 10 11 •)FOR USE WITH WIDE 0Iii: Bn Ii) Q 0 O ANGLE FLOAT SWITCH(ONE I I FLOAT FOR BOTH ON AND BLACK I I I I I I LI F-I OFF OPERATION).JUMP tiDRY CONTACTS TERMINALS(3)AND(4), J10 l I I I I I 0� INSTALL WIDE ANGLE FLOAT I I I I J2 TO TERMINALS(1)AND(2). I I I I �� ALARM FLOAT ®FACTORY WIRED FOR(3)FLOAT OPERATION.FOR(4)FLOAT I I Y LAG FLOAT OPERATION,REMOVE JUMPER(J2) 1 (OPTIONAL)* FROM TERMNALS(6)AND(8).INSTALL 6 LEAD FLOAT LAG FLOAT ON TERMINALS(5)AND(6). OFF FLOAT* PAGE S HD Fowler Note: North Duplex CentriPro Wastewater Pump Lift Station DUPLEX THREE PHASE WIRING DIAGRAM - D3 — — — — S1 T�G 0 0 - • 1 ��_` V_oz .O� © - - PUMP I NO.1 �ir7Cr0—_ T © - , S2 IDO 208/230/460/575 VAC 2 `■ THREE PHASE © 0 04-a o— I © - - No z 60 HE Ell© O %� T © - , a a a > > o m FACTORY WIRED FOR 460 VAC.FOR 208,230 OR 't o FOR 575 VAC OPERATION CHANGE CONTROL 2A 75 VA TRANSFORMERPRIMARYAT TERMINAL BLOCK. WHITE —® 12!)VAC !I 9 CONTROL III / ON-OFF 0 RUN BLACK OHAND 0 OFF PURPLE • 'S 10` YELLOW 00 AUTO ALTERNATOR SWITCH- STANDARD ON ALL DUPLEX PANELS,THIS RUN SWITCH PROVIDES BLACK HAND :0: OPTIONS FORLIALTERNATE • 0 PUMPS,USE ONLY PUMP 1 OFF BLUE • CI)O OR USE ONLY PUMP 2.IT IS /° USED WHEN A PUMP IS ORANGE o REMOVED FOR SERVICE. AUTO 7 FOR SEPARATE 120 VAC CONTROL POWER SUPPLY, RED REMOVE JUMPER(J1)FROM TERMINALS(H)AND(L1). 0 \ ALTERNATOR SWITCH O TEST CONNECT 15 AMP MAX. R1 y PUMP 1 TEST 11, RE o o— PROTECTED 120 VAC SUPPLY rii ALT TO TERMINALS(L1)AND(N). PUMP 2 SILENCE WITH THE NEUTRAL OF THE nn * YEL R2 MUTE,r YELLOW I SUPPLY TO(N). 'L n i . i . i i n RESET )FOR USE WITH WIDE ANGLE YC ,O, O ,O O RESET V BR% 10� FLOAT SWITCH(ONE FLOAT OFF LEAD LAG ALARM BROWN FORBOTH ON AND OFF Jn� OPERATION).JUMP TERMINALS FLASHING FLASH (3)AND(4),INSTALL WIDE RED `O\ ANGLE FLOAT TOTERMINALS nVJ� L1 l n N1r`nn SONALERT I PINK WHIT (1)AND(2). J HORN J FACTORY WIRED FOR(3) H L1 N 1 2 3 4 5 6 7 8 9 10 11 FLOATOPERATION FOR(4) FLOATOPERATION,REMOVE I�'II`� O A A GI nn ? ? ? 7 ? ? ? ® O JUMPER(J2)FROM TERMNALS BLACK (6)AND(8).INSTALL LAG I I I I I Li hJ FLOAT ON TERMINALS •.� I I I I I I I tiDRYCONTACTS (5)AND(6). J1Q 0.0(�0� I I I I J2 I I I ALARM FLOAT I b LAG FLOAT (OPTIONALJ ) �� LEAD FLOAT OFF FLOATa. PAGE 6 HD Fowler Note: South Duplex Pump Lift Station TECHNICAL BROCHURE B3888D4 ae' � FEATURES Impeller: Cast iron,two vane semi-open, non-clog with pump-out ' uiFo ,ns vanes for mechanical seal protection. Balanced for smooth operation. Silicon bronze impeller available as an option. s.w.g,pump a ® Casing: Heavy duty gray cast iron,ASTM A48,Class 30.Volute type casing with 4", 125#,ANSI flanged,horizontal discharge.Compatible with Al 0-40 cast iron or Al0-408 cast iron and brass(non-sparking) guide rail assembly. Dual Mechanical Seals: Silicon carbide vs.silicon carbide outer seal and ceramic vs.carbon inner seal,stainless steel metal parts, BUNA-N elastomers.Upper and lower shaft seals are positioned independently and are separated by an oil-filled chamber. " Shaft: 300 series stainless steel keyed design. Fasteners: 300 series stainless steel. Capable of running dry temporarily without damage to seals or motor. WS_D4Series Model 3888D4 SUBMERSIBLE SEWAGE PUMPS 4 GOULDS a xylem brand HD Fowler Note: South Duplex Goulds Water Technology Wastewater Pump Lift Station I APPLICATIONS Three Phase: Used in a variety of residential,commercial and • 1.5 -7.5 HP; 200,230,460 and 575 volts industrial applications such as: •Class 10 overload protection must be provided in • Sewage systems, Flood and Pollution Control, control panel Dewatering/Effluent, Farms, Hospitals,Trailer Courts, MOTORS Motels • Fully submerged in oil-filled chamber: High grade SPECIFICATIONS turbine oil surrounds motor for more efficient heat Pump: dissipation, permanent lubrication of bearings and • Maximum solid size: 3" mechanical seal for complete protection against • Discharge size:4", 125#ANSI flange outside environment. • Maximum capacity: 620 GPM • Class F insulation • Maximum total head: 60 feet • Designed for Continuous Operation: Pump ratings • 300 Series stainess steel fasteners are within the motor manufacturer's recommended • 20' Power cord working limits and can be operated continuously • Standard silicon carbide/silicon carbide outer seal without damage when fully submerged. Motor: • Bearings: Upper and lower heavy duty ball bearing construction for precision positioning of parts and • Maximum ambient temperature: 104°F(40°C) to carry thrust loads. continuous duty, 140° F(60°C)intermittent duty • Rated for continuous duty when fully submerged • Power Cable:Severe duty rated,oil and water • Insulation: Class F resistant.Epoxy seal on motor end provides secondary moisture barrier in case of outer •60 Hertz jacket damage and to prevent oil wicking.20 foot • Single row ball bearings standard with optional lengths available. • 300 Series stainless steel keyed shaft • 0-ring; Assures positive sealing against Single Phase: contaminants and oil leakage. • 1.5-5 HP; 208 and 230 volts AGENCY LISTINGS • Built-in thermal overloads with automatic reset • Built-in capacitors A A® TestedBy toCanadian ULStandards 778 and CSA 22.2Association 108 Standards f7 Cl us File#LR38549 MODEL AND MOTOR INFORMATION Order No. HP Phase Volts RPM Impeller Maximum LR. KVA Power F.L.Motor Resistance Wt. Dia.(in.) Amps Amps Code Cable Efficiency% Start Line-Line (lbs.) WS1518D4M 208 17.2 50.8 B 80 1.1 0.9 WS1512D4M 1 230 14.7 29.5 E 14/3 70 1.4 1.8 WS1538D4M 200 11.5 40.9 H 81 1.7 1.5 1750 5.63 195 WS1532D4M 230 10.0 40.0 F 83 2.3 W51534D4M 3 460 5.0 20.0 F 14/4 83 NA 9.3 WS1537D4M 575 4.0 14.4 H 74 14.8 WS1518D4 - 208 17.2 50.8 B 80 1.1 0.9 WS151204 1 230 14.7 29.5 E 14/3 70 1.4 1.8 WS1538D4 - 1 5 200 1750 6.25 11.5 40.9 H 81 1.7 195 WS153204 23010.0 40.0 F 83 2.3 WS1534D4 3 460 5.0 20.0 F 14/4 83 NA 9.3 WS1537D4 575 4.0 14.4 H 74 14.8 WS2018D4 208 20.3 50.8 B 80 1.1 0.9 WS2012D4 1 230 17.3 36.9 D 14/3 75 1.4 1.5 WS203804 200 13.3 40.9 H 81 1.7 WS2032D4 2 230 11.6 40.0 F 83 2.3 1750 6.63 200 WS2034D4 ' 3 460 5.8 20.0 F 14/4 83 NA 9.3 W52037D4 , 575 4.6 14.4 H 74 14.8 W53018D4 208 25.5 50.8 B 80 1.1 0.9 WS3012D4 1 230 21.5 46.4 C 10/3 79 1.0 1.0 208 W53038D4 200 16.6 53.8 G 10/4 85 1.3 WS3032D4 3 230 1750 7.00 14.4 49.5 _ H 83 1.9 WS3034D4 3 460 7.2 24.8 H 14/4 83 NA 7.5 5 205 WS3037D4 575 5.8 17.3 G 78 11.6 W55012D4 1 230 26.5 57.7 A 10/3 80 1.0 0.8 213 WS5038D4 200 19.1 73.9 F 10/4 84 0.9 WS5032D4 5 -2� 1750 7.25 16.6 63.6 E 85 1.2 W55034D4_ 3 460 8.3 31.8 E 14/4 85 NA 4.8 210 WS5037D4 575 6.6 22.8 E 80 7.4 WS7532D4 230 23.0 105.0 G 83 0.7 WS7534D4 7.5 3 460 1750 7.69 11.5 52.5 G 10/4 83 NA 2.8 225 W87537D4 575 9.2 42.0 E 84 4.4 PAGE 2 HD Fowler Note: SouthuthDuplex Goulds Water Technology Wastewater Pump Lift Station MATERIALS OF CONSTRUCTION Item Material Part Name �.. __-__ 6 No. Standard Optional I 1 Impeller,non-clog 1003 1179 2 Casing 1003 3 Shaft-keyed 300 Series SS I . 5 7 4 Fasteners 300 Series SS 1 3 if 5 Ball bearings Steel ti 6 Power cable STOW,20 feet Additional lengths 8`' 7 0-ring BUNA-N _____Liii,„4 Out Seal Service Rotary Stationary Elastomen Metalrts 2 J 8 OPT Heavy duty Silicon Tungsten BUNA-N 300 Series Carbide Carbide SS Mild 300 Series PERFORMANCE RATINGS(gallons per minute) STD Silicon carbide BUNA-N abrasives SS Material Code Engineering Standard Series No. ►WS15D4M W515D4 W520D4 WS30 WSSO W575D4 1003 Cast iron-ASTM A48 Class 30 HP I. 1'/s 1 6 2 3 5 01 71/2 RPM 1.- 1750 1179 Silicon bronze-ASTM C87600 10 300 395 15 170 320 370 `y 20 230 300 440 520 s' 25 120 205 365 440 xe 3 30 100 270 360 510 'm 0 35 160 275 440 .61 To h m 40 80 175 355 u. 45 85 260 50 155 55 80 METERS FEET 70 . r 1 ! i , 1 , 1 L - ( i ' — SERIES WSSIZE 3"J 20- 1 I.. I R RPM 1750 S I , _ VARI T 60 ' . . _ , I L __ t _ r - III Iles, 4 O , �� 1 ( i --Ow10GPM 15- 50It w3 S O + 004 �2 FT i ) lNs3t) U 40 04 1 1 I 1 . a >- Ws-, 0 30 S 04 Q WS1s04 I O '' I 5 WS1g0gM ; 1 „ 0 - 0 0 50 100 150 200 250 300 350 400 450 500 550 600 U.S.GPM 0 20 40 60 80 100 120 140 m3/hr FLOW RATE PAGE 3 r HD Fowler Note: South Duplex 1 Pump Lift Station APPLICATION DATA AND CONSTRUCTION DETAILS Maximum Solid Size 3" Minimum Casing Thickness s/n" Casing Corrosion Allowance 'A" Maximum Working Pressure 30 PSI Maximum Submergence 50 feet Minimum Submergence Fully submerged for continuous operation 6"below top of motor for intermittent operation Maximum Environmental Temperature 40°C(104°F)continuous operation,60°C(140°F)intermittent operation Power Cable-Type Type SJTOW:single phase,11 and 2 HP Type STOW:single phase,1 1-3 HP and 5 HP,460 V (See Motor Information forAwG data/size.) Type STOW:single phase,3 and 5 HP,three phase 5 HP,230 V and 71/2 HP Motor Cover,Bearing Housing,Seal Housing,Casing Gray Cast Iron-ASTM A48,Class 30 Impeller-Standard,Optional Gray Cast Iron-ASTM A48 or Cast Bronze-ASTM B584 C87600 Motor Shah AISI 300 Series Stainless Steel Motor Design NEMA 56 Frame,oil filled with Class F Insulation Motor Overload Protection Single phase:on winding thermal overload protection auto reset Three phase:requires Class 10 overloads in control panel External Hardware 300 Series Stainless Steel Impeller Type Semi-open with pump out vanes on back shroud Oil Capacity-Seal Chamber 1.5 quarts Oil Capacity-Motor Chamber 1 Y-5 HP single and three phase:7 quarts 71/2 HP three phase:6.5 quarts Mechanical Seals-Standard Upper Carbon/Ceramic;Type 21 Lower Silicon Carbide/Silicon Carbide;Type 31 Mechanical Seals-Optional Lower Silicon Carbide/Tungsten Carbide;Type 31 DIMENSIONS (All dimensions are in inches.Do not use for construction purposes.) . ® /'. ROTATION iii 12.62" "N/'�I 28.25" 4"125 L `�drI ANSI FLANGE i 5.75" I 1 b•�5" KICKBAC 3.50" y xylem Xylem,Inc. l Let's Solve Water 2881 East Bayard Street Ext.,Suite A Seneca Falls,NY 13148 Phone:(866)325-4210 Fax:(888)322-5877 www.xyleminc.com/brands/gouldswatertechnology Goulds is a registered trademark of Goulds Pumps,Inc.and is used under license. SKr is a registered trademark of Aktiebolaget SKr,Sweden. 0 2012 Xylem Inc. 83888D4 R1 April 2012 HD Fowler Note: South Duplex Pump Lift Station TECHNICAL BROCHURE BCP4 R12 FEATURES (at CentnPro® NEMA 4X,30 watt,flashing red light and alarm horn-95db. Duplex NEMA 4X,fibergenclosurelass gasketed, hinged door Weatherproof gass with g Panel and stainless steel hardware. Entire unit is UL and CUL listed. e .4y Single Phase Field adjustable for 115,208 or 230V,60 Hz. 2 pump circuit breakers. Three Phase Field adjustable for 208/230/460/575V,60 Hz. 115V control circuit transformer. 2 adjustable motor overload protectors. Heaters not required. Provides fully automatic operation for two pumps. Solid state pump alternator circuit displays float status for ease of installation and trouble shooting. DUPLEX NEMA 4X WEATHERPROOF PANELS SINGLE AND THREE PHASE CONTROL PANELS CentriPro a xylem brand HD Fowler Note: South Duplex Ce ntri Pro Wastewater Pump Lift Station APPLICATIONS • Hinged door with lockable stainless steel latch for Superior quality duplex liquid-level controller,auto- safe operation indoors or out. matically controls alternation for two pump operation. • High-level alarm circuit includes through-door High-level alarm warning designed for a variety of mounted silence switch for manual silence of alarm sump,effluent,sewage and water transfer applica- horn. tions. •Through-door mounted alarm test switch insures SPECIFICATIONS proper operation of the alarm circuit without the need to open the panel. •Accepts single or dual power feed. •Two through-door mounted pump run lights. •2 hand-off-automatic(H-O-A)pump switches. •Top-mounted high intensity flashing red light pro- •On-off control circuit switch. vides 360°visibility. •2 oversized magnetic contactors. • Pulsating,corrosion proof alarm horn. • Numbered terminal strip-screw type. •These duplex controls are factory wired for opera- • Float Switches-Note: Please order float switches tion with three float bulbs.An easy field modification separately.We offer several types and models.See for four float bulb operation using separate"lag-on" the Float Switch bulletin for available options.The and "alarm bulbs"is provided. type selected determines the quantity needed. •Alternator selector switch allows a choice of auto- The basin depth and panel location determine the matic alternation or operation of only pump 1 or required cord length.Contact your distributor or pump 2.Typically used if one pump is down for Customer Service for additional information. maintenance. • Electronic pump alternator. • Lag pump-start delay built-in. Delays starting lag •Alternator selector switch. pump for 5 seconds if both pumps attempt to start • Lag pump start delay. simultaneously as after a power outage. • Panel can be wired for a single power feed for FEATURES pumps and control circuit or the control circuit can • be wired to a separate power supply to insure alarm Rugged, NEMA 4X construction withstands even the integrity in case of a tripped main breaker. most severe weather conditions and prevents corro- sion. •Auxiliary alarm contacts provided for remote alarm connection. • Provides fully automatic operation for two pumps. Alternates pump starting to distribute operating •Color coded wiring,screw type terminals and plug time. Provides extra pumping capacity in times of in sockets,ensure ease of field servicing. high inflow by energizing both pumps. • Field wiring diagram,panel schematic and installa- •Alternator selector toggle for maintenance on one tion instructions included. or both pumps. • Requires three float switches or with optional fourth lag float,order separately. PANEL MODEL INFORMATION SINGLE PHASE PANELS THREE PHASE PANELS ORDER NUMBER AMP/HP RANGE ORDER NUMBER AMP RANGE D10020 0-20 AMPS D31625 1.6-2.5 D12127 3 HP D32540 2.5-4.0 D12836 5 HP D34063 4.0-6.3 D36310 6.3- 10 D31016 10- 16 D31620 16-20 D32025 20-25 D32232 22-32 PAGE 2 HD Fowler Note: South Duplex CentriPro Wastewater Pump Lift Station ADDITIONAL OPTIONS Code(add as required) P = Special duplex Mini CAS seal fail and high A = Guaranteed pump submergence circuit temperature circuit for use on only three phase 15/20GD, 15/20GX, 1 GA/2GA,GV Plus and C = 115V condensation heater Impact pumps.For single phase,see CentriPro D = Single phase lightning arrestor single phase grinder control panels bulletin E = Three phase lightning arrestor BCP1 PGP for standard, BCP1 PC1 P for explosion proof. G = Elapsed time meter(2)-Duplex T = 4 intrinsically safe relays in duplex panel J = Seal fail circuit(2)-Duplex YY= Duplex dry contact for seal failure interface to L = Cycle counter(2)-Duplex building management system. N = High temp.indicator with pump shutdown - ZZ= Duplex dry contact for pump running interface to Duplex building management system. When ordering options,add the appropriate code number as a suffix to the panel order number. Example...D31625CG adds a condensation heater and(2)elapsed time meters. ENCLOSURE DIMENSIONS (in inches) Single Phase A B C D E F G 10.1 15.5 18.3 14.8 6.8 7.2 13.3 Three Phase A B C D E F G 12.1 17.5 20.3 16.8 6.8 7.2 15.3 NOTE:Mounting holes are33/e". A �� ��� A C B D y r 0 ENE0 A E F PAGE 3 HD Fowler Note: Ce ntri Pro South Duplex Wastewater Pump Lift Station SINGLE PHASE COMPONENTS THREE PHASE COMPONENTS 1. NEMA 4X enclosure 1. NEMA 4X enclosure 2. Flashing alarm light 2. Flashing alarm light 3. Alarm horn(RB50) 3. Alarm horn(RB50) 4. Pump run light 4. Pump run light 5. Alarm silence button 5. Alarm silence button 6. Alarm test button 6. Alarm test button 7. Control power on/off switch 7. Control power on/off switch 8. H-O-A switch 8. H-O-A switch 9. Alarm reset button 9.Alarm reset button 10. Contactor(R832) 10.Contactor(RB47) 11.Terminal strip 11.Terminal strip 12.Alternator circuit(RB75) 12.Alternator circuit(RB75) 13. Motor circuit breakers 13.Control transformer 14. Motor circuit protectors(RB52 through 57) 2 2 0 • 0 0 • 0 • • NO 0 • • O 0 7,8 7,8 3 I 14 13 0 0 nnn o o 1 nnn 011E I11 ooE 1 „ .v0 _ 0 0 0�0 - 0 3 3 PAGE 4 HD Fowler Note: Ce ntr� Pro South Duplex Wastewater Pump Lift Station DUPLEX SINGLE PHASE WIRING DIAGRAM - D10020 NOTE:The standard panels shown in this book are not designed to be used with pumps requiring external capacitors.See the catalog for panels with built-in capacitor packs. 25A S1 oTo I O - yy�\�� FOR 120 VOLT OPERATION T PUMP NO.1 USE TERMINALS(L1)AND(N) o o JUMP TERMINALS(N)AND(L2) r — — 25 A 52 1 u i • o I O - yyam� I 2T _ 0 PUMP NO.2 230 VAC I SINGLE PHASE Ikg) 1 • ° o I 60 HO 1 1 I O i WHITE I I I GIB I I / CONTROL ON-OFF zz- RUN A 230 VOLT SYSTEM BLACK HAND :O' REQUIRES A 4 WIRE POWER SUPPLY LINE o OFFFPURPLE • S1 L1,L2,N AND GND. YELLOW p/AUTO WITHOUT A NEUTRAL THE CONTROL CIRCUIT WILL NOT WORK. RUN •BLACK 0HAND • O OFF•BLUE Cli ALTERNATOR SWITCH- ORANGE O AUTO O STANDARD ON ALL DUPLEX PANELS,THIS SWITCH PROVIDES OPTIONS FORD ALTERNATE PUMPS,USE RED ONLY PUMP 1 OR USE ONLY PUMP 2.IT IS USED WHEN A 0 ALTERNATOR SWITCH Q TEST PUMP IS REMOVED FOR JJ�L PUMP 1 RED—L SERVICE. Y R1 El ALT TEST n7nt PUMP 2 �J11 SILENCE [R2 MUTE,r Y YE O O� "LLL ll' YELLOW 'FOR SEPARATE 120 VAC nJ� RESET CONTROL POWER SUPPLY, V .0, .�. .�� RESET 4 BR REMOVE JUMPER(J1)FROM OFF LEAD LAG ALARM C BROWN TERMINALS(H)AND(L1). FLASHING FLASH CONNECT 15 AMP MAX. RED :0: PROTECTED 120 VAC SUPPLY J1 pp TO TERMINALS(L1)AND(N). t L1 4 N1r SONALERT PINK HORN WITH THE NEUTRAL OF THE L `` WHITE SUPPLY TO(N). H L1 N 1 2 3 4 5 6 7 8 9 10 11 ANGLE FLOAT SWITCH(ONE n n �I I II ( I O FOR USE WITH WIDE 0 0 0 O FLOAT FOR BOTH ON AND BLACK I I I I I I Li F1 OFF OPERATION).JUMP TERMINALS(3)AND(4), ,11C-------`-' I I I I I I DRY CONTACTS INSTALL WIDE ANGLE FLOATI I I J2 TO TERMINALS(1)AND(2). I I I I y ALARM FLOAT S FACTORY WIRED FOR(3)FLOAT b� OPERATION.FOR(4)FLOAT I I jib LAG FLOAT AL)&9 OPERATION,REMOVE JUMPER(J2) I o FROM TERMNALS(6)AND(8).INSTALL LEAD FLOAT LAG FLOAT ON TERMINALS(5)AND(6). OFF FLOATS PAGE 5 HD Fowler Note: South Duplex Ce ntri Pro Wastewater Pump Lift Station DUPLEX THREE PHASE WIRING DIAGRAM - D3 -- -- s1 T' "0 1 0 - — 1 © _ _ PUMP I NO.1 ^0 0.°._ 1 T 0 _ , 52 208/230/460/575 VAC O ■ � � 2 - THREE PHASE © e - - No 2 60 HO 1 !I��00 T © - U UO U n 0 m o FACTORY WIRED FOR 460 VAC.FOR 208,230 OR v N N FOR 575 VAC OPERATION CHANGE CONTROL 2A 75 VA TRANSFORMERPRIMARYATTERMINALBLOCK. WHITE ® 14-v 12a VAC O CONTROL / ON-OFF ° RUN BLACK O HAND Ho. i O OFF PURPLE • ST` YELLOW ° AUTO ALTERNATOR SWITCH- STANDARD ON ALL DUPLEX PANELS,THIS RUN SWITCH PROVIDES BLACK HAND ,O, OPTIONS FOR©ALTERNATE • ° PUMPS,USE ONLY PUMP 1 OFF BLUE OR USE ONLY PUMP 2.IT IS ° USED WHEN A PUMP ISNTERNATOR GE REMOVED FOR SERVICE. °AUTO O FOR SEPARATE 120 VAC CONTROL POWER SUPPLY, RED REMOVE JUMPER(J1)FRO TERMINALS(H)AND(L1). SWITCH O TEST CONNECT 15 AMP MAX. ❑ ALT 1 TES RED 0- PROTECTED 120 VAC SUPPLY I( ALT 2 SILENCE TO TERMINALS(L1)AND(N). 1I WITH THE NEUTRAL OF THE R2 MUTE{ „ YELO G SUPPLY TO(N). 11 YELLOW I n i i RESET a FOR USE WITH WIDE ANGLE V C ,O` ,OO ,O, ,O, RESET t ¢ BRV D� FLOAT SWITCH(ONE FLOAT OFF LEAD LAG ALARM BROWN FORBOTH ON AND OFF nnJ� OPERATION).JUMP TERMINALS FLASHING FLASH (3)AND(4),INSTALL WIDE L! RED ` ANGLE FLOAT TOTERMINALS jj�� ,O` (1)AND(2). j PINK wig,.N SONALFRT I HORN 7 G3'FACTORY WIRED FOR(3) H L1 N 1 2 3 4 6 5 7 8 9 10 11 FLOATOPERATION.FOR(4) FLOATOPERATION,REMOVE 7-0 On ? nil----? --,II , 1 0 , (T) O JUMPER(J2)FROM TERMNALS BLACK (6)AND(8).INSTALL LAG I I I I I Li Li tJ FLOAT ON TERMINALS J10_f I I I I I I kt DRY CONTACTS (5)AND(6). I I I I J2 1 I I I ALARM FLOAT I Ib LAG FLOAT y (OPTIONAL)® LEAD FLOAT OFF FLOAT® PAGE 6 xy le m Let's Solve Water TECHNICAL BROCHURE BCPCGR R14 ' II • TRW t I. 4 i 4r s Si 3 . Guide Rail Systems EFFLUENT AND SEWAGE Centri Pro a xylem brand Ce ntri Pro Wastewater FEATURES Al 0-30, 3"X 4"RAIL SYSTEM:Connects to any ALL MODELS: pump with a 3", 150#ANSI flanged discharge.Outlet Cast iron construction for standard applications. is a 4"flanged discharge. Optional brass pump adapter for applications Al 0-40, 4"X 4"RAIL SYSTEM:Connects to any requiring a non-sparking disconnect. pump with a 4", 150#ANSI flanged discharge.Outlet Standard kit contains a base,a pump adapter with all is a 4"flanged discharge. required bolts and fittings,and the upper guide rail Al 0-60, 4"X 6" RAIL SYSTEM:Connects to any positioning bracket. pump with a 4", 150#ANSI flanged discharge.Outlet Optional intermediate guide rail brackets are available is a 6"flanged discharge. in either steel or brass for non-sparking applications. Guide rails are not supplied -they may be sourced locally-2" stainless steel guide rails recommended. Spare pump adapter kits are available for those who want a back-up pump/adapter ready for an emergency quick change. 3"AND 4" DISCHARGE GUIDE RAIL SYSTEM Pump Part Discharge Number A Max. C H J Weig ht 311 Al 0-30 4°/16 333/s 22' 63/4 11±1/4 170 lbs. Positioning 4" A10-40 373/16 34144 23 7344 12±1/4 185 lbs. Bracket mis =MS Top View El- - -I& -1 2„ I f 4--33/a' 1 I NO11.,!C'��''�I „. (2)2"Pipe Guide Rails ,iv I i 9 1 n ih I 1"I �. by installer �' 1 „• NOTE: i __y-__O II= =ll 1 Motor Frame; I � ' ', 1 �� -f• Reliance-180Ty I 1 7s/16" ter - 7J� 1 I MIN Base 1 4" 150 PSI '-H ".—"F' l I I ANSI Flange ISI. �M /17 ' V� Positioning HI1BONde ,J I\ Bracket i 12" �" ` t 7„ 0 AIHiles -L 1" f H ( i 1' i B r i PAGE 2 Centri Pro Wastewater 3"AND 4" DISCHARGE GUIDE RAIL SYSTEM • Heavy duty cast iron construction. • System Components Include: •Twin guide rails provide positive alignment with • Base with integral cast elbow. base. • Pump adapter-guide assembly with fasteners. • No sealing devices required-pump weight provides • Upper guide rail positioning bracket. Carbon steel sufficient force for proper seal. bracket available as an option in stainless steel. • Self cleaning design.When pump flange engages base,the shearing action wipes the sealing surfaces NOTE:Guide rails are not furnished by CentriPro. clean. Lifting chains and bails need to be ordered separately.Intermediate bracket available as seen on page 4 for pits over 11 feet. 4" DISCHARGE GUIDE RAIL SYSTEM Pump Part g Frame Wei A Discharge Number 210 4" A10-60 373/4 185 lbs. 250 4" A10-60 43'/8 185 lbs. Positioning Top View ' Bracket 1§§......m 1 1 1 f' -Ir. %. II ,,. u• I I 11 911 21 MIH I I i 1 D' r'' 33/SH --I---- `'41IYa�41111 - 1 *.'%f' -'.' 1 ` II (2)2"Pipe Guide Rails it — y J _L / byinstaller MIH I,I! B5/1/i' r II I n n II" 261/2" I T �_ 6"150 P51 p ''INI g„ 1 I ANSI Flan e 0 t lal�hO MI V tii:\ I APositioning I 77".'''''''-- Bracket N■ I i /rf 6/e' � 1 0•o o" -,. I I 1 10" e Holes •� 1 1" \\N.,1..,...______.---Me .......„...„„.„) I 393/4" I PAGE 3 PUMP ADAPTER KITS 0 r� i--_ 1K340-for Al 0-30 iron 1K341 -for Al 0-40/A10-60 iron 1 K447-for Al 0-30B brass 1 K448-for Al 0-40B/A10-60B brass _ Part numbers are for repairs,component is included in the A 10-30,40 accessory. INTERMEDIATE GUIDE RAIL BRACKET 0 A10-30(B)standard 4K436 0 A10-40(B),60(B)standard 4K437 e ("/70 A10-30 304 SS 4K631 O -�--��� Al 0-40 304 SS 4K632 •., Used on pits over 11 feet for extra support. 0 Must be purchased separately. A lb. MINIMUM BASIN DIAMETER kt j Minimum Recommended -- g1 �.... Simplex 36" 42" • . . Duplex 48" 60" �1• e UPPER GUIDE RAIL BRACKET 41100- V A10-30(B) 4K467 A10-40(B),60(B) 4K468 0 Pump Discharge Order ANSI Flanged Material of Used On These Pumps Size Number Discharge Size Positioning Bracket 3" A10-30 Carbon Steel 3WDA,3DWS,3WS,3888D3,3SD 3" Al 0-30SS Stainless Steel 3GV,3MV,3MK 4" 150 lb.ANSI A10-40 Carbon Steel 4" Al 0-40SS 4WDA,4DWS,4DWN,4WS,3888D4,4SD,4NS 4" Al 0-40SS Stainless Steel 4GV,4MV,4MK 6" 150 lb.ANSI 4" Al 0-60SS 3"XP Al 0-30B 3XWC,3SDX,3GVX,3MVX,3MKX 4" 150 lb.ANSI 4"XP Al 0-40B Carbon Steel 4XWC,4XWN,4SDX,4GVX,4MVX,4MKX 4"XP Al 0-60B 6" 150 lb.ANSI 4XWC,4XWN,4XD,4SDX,4GVX,4MVX,4MKX *For 6MK units,see Conery base elbow CBE6060. xylem Xylem Inc. Let's Solve Water 2881 East Bayard Street Ext.,Suite A Seneca Falls, NY 13148 Phone:(866)325-4210 Fax:(888)322-5877 www.xylem.com/centripro CentriPro is a trademark of Xylem Inc.or one of its subsidiaries. 02018 Xylem Inc. BCPCGR R14 November 2018 TECHNICAL BROCHURE BCPFS 1 f . 4 ; /y i 1 0 PUMP / CONTROL PANEL SWITCHES Centri Pro a xylem brand Ceritr Pro Wastewater . . ,. A2D SERIES A2HT SERIES SJE PumpMaster'Pump Switch High Temperature Float Switch Features Features • Mechanically activated, heavy duty •Temperature Rating: 221° F(105° C) contacts,wide angle operation. •Wide Angle Switch: contacts open @ 45°below 6'liin • Passed NSF standard 61 protocol "` horizontal and close at 45°above horizontal by an approved Water Quality Association laboratory. • Float Material: PC/ABS(Polycarbonate ABS) •Controls pumps up to 1/2 HP at • Cord Material:Teflon coating 120 VAC and 1 HP at 230 VAC. • Ratings: 13 Maximum Amps, Y2 HP, 115/230 V • Non-corrosive PVC housing for • Float Dimensions: 4.63" Long x 2.63" Diameter use in liquids up to 140°F (60°C). • Nomenclature: see page 9 • Not sensitive to rotation •Available lengths:20', 30' and 50' * or turbulence. NOTE:A2HTL High Temperature Rating: 185° F • Pumping range: 7"to 36". "No other lengths available an this Series. • 16 AWG,SJOW cord is available with or without piggyback plug. •Available as pump up,pump down and SPDT models,see Nomenclature Chart. • For potable water,water or sewage applications. • UL Recognized for use in water and sewage. •CSA Certified. • See chart for amperage range and other data. SAP. A2E SERIES SJE PumpMaster Plus' Pump Switch Features • Controls pumps up to 3/ HP at 120 VAC and 2 HP at 230 VAC. • 14 AWG, SJOW cord is available with or without piggyback plug. •All other features are the same as A2D PumpMaster Series above. PAGz3 CentriPro Wastewater PUMP SWITCHES (WIDE ANGLE) can be connected directly to a pump CONTROL SWITCHES (NARROW ANGLE) can only be used with control panels or alarm panels Order Maximum Running Maximum Starting Cord Length Bare Pump Control (1) (2) Mounting Number Amps Amps (Feet) Leads Switch Switch N.O. N.C. Strap Weight A2013 10 X X - X X A2D14 X X - X X A2D23U X X - X X A2D23W 15 X X - X X X A2D33 X X - X X A2D33U X X - X X A2033W 3 20 X X - X X X A2D34 X X - X X A2D34W X X - X X A2D53W 30 X X - X X X A2D63W 50 X X - X X X A2D83W 85 100 X X - X X X A2E03 4 X X - X X A2E23 X X - X X A2E23U 15 X X - X X A2E33 20 X X - X X A2F53 30 X X - X X A2ES3U 15 X X - X X A2E63 50 X X - X X A2E63U X X - X X A2E73 75 X X - X X A2E83 X X - X X A2E83U 100 X X - X X A2G23 15 X X - X X A2G33 20 X X - X X A2G43 20 120 25 X X - X X A2G53 30 X X - X X A2G63 50 X X - X X A2H33 12 60 20 X X - X X A2HTL13 10 X X A2HTL33 20 X X X X X A2HTL53 30 X X X X X A2HT13 13 58 10 X X X X X A2HT33 20 X X X X X A2HT53 30 X X X X X A2HT63 50 X X X X X A2NO3 3 X - X X X A2N13 10 X - X X X A2N23 X - X X X A2N23W 15 X - X X X A2N23WB X - X X X A2N23WU X - X X X A2N33 X - X X X A2N33U X - X X X A2N33W X - X X X A2N33WB 20 X - X X X A2N33WU X - X X X A2N34 X - X X X A2N43W 5 25 X - X X X A2N43WU N/A X - X X X A2N53 X - X X X A2N53W 30 X - X X X A2N53WU X - X X , X A2N63 X - X X X A2N63W 50 X - X X X A2N73 X - X X X A2N73W 75 X - X X X A2N83 100 X - X X X A2N83U X - X X X A2N93 125 X - X X X A2S23 15 X - X X X A2S53 10 30 X - X X X A2S63 50 X - X X X A2T33 15 90 20 X - X X X A2X03 7 X - X X X A2X13 70 X - X X X A2X13U X - X X X A2X23 15 X - X X X A2X23U X - X X X A2X33 See Description N/A X - X X X A2X33U 20 X - X X X A2X33W X - X X X A2X53 X - X X X A2X53U 30 X - X X X A2X63W X - X X X N.O.(1)=PUMP DOWN N.C.(2)=PUMP UP PAGE 6 Centri Pro Wastewater NOMENCLATURE A2 HTL 3 3 PTIONS OPTIONS U - Pump Up or Normally Closed (NC) W = A2WT Cable Weight B = Bulk Packed (internal only) Style of Cord 1 = 115 V piggyback 2 = 230 V piggyback 3 = Bare lead 4 = Single pole double throw(SPDT) Length of Cord 1 = 10' 2 = 15' CO 3 = 20' 4 = 25' a 5 = 30' 6 = 50' 7 = 75' 8 = 100' Only available on select control switches. 9 = 125' Type of Switch D = PumpMaster-SJE E = PumpMaster Plus'-SJE G = AmpMaster'-SJE H = VerticalMaster°-SJE J = VerticalMaster II-SJE N = SignalMasterTM-SJE P = MicroMaster° Plus-SJE R = MicroMaster`-SJE S = C I Diaphragm Level Switch-MP T = Double Float' Master-SJE X = MilliAmpMasterTM HT = High Temperature-MDI-221° HTL= High Temperature-MDI- 185° Float Switch PAGE 9 FLOAT (ACCESSORIES To Finish Any Onsite Installation CABLE CLAMP ASSEMBLY EIGHT MINI Anti Provides cable anchor point and strain relief.Secures cable in Provides an accurate pivot point for suspended float switches. vertical direction. One piece cable weight • For use with 18/16 gauge,14 gauge,&12 gauge cable • Turn and Lock for easy installation 1 MOUNTING CLAMP:ABS Nylon blend HOUSING: 9.6 ounces(0.27 kgs.),2.5 inch diameter x 2.5 HOSE CLAMP:highly corrosion resistant stainless steel inch long(6.35 cm diameter x 6.35 cm),impact resistant,noncorrosive,PVC housing for use in AC liquids up to 140°F(60°C) WIRE/CABLE ACCOMMODATED:SJOW,SJTW,18/2,18/3 Provides convenient installation of float switches. NOTE:The Cable Weight Mini can be used on the following control switches • Six Float Bracket supports 1-6 floats with 18/2 or 18/3 cable: • Four Float Bracket supports 1-4 floats 3 • SJE SignalMaste • Can be directly mounted to wall or • SJE SignalMastere SPDT used with wall mounting device • SJE MilliAmpMaster'" • Provides convenient location to stow excess • Sensor Float®Mini float cord • Supplied with UL Recognized cord strain f ELAN' METER WITH PIGGY-SACK PLUG relief connectors . 4itiollt. Plugs into switched outlet or piggy-back switch G METAL COMPONENTS: all metal components of plugger control panel.Unit must be placed _�_' are made of 300 series inside an enclosure. stainless steel • Screws and mounting adhesive included STRAIN RELIEF CONNECTORS: which accommodate _:00'',,, 18/2,18/3,16/2, - 'w 16/3 SJTWcordss v o VERTICAL REED SWITCH sJTW c • Control differential:.375 inch(1 cm) IMO MOUNTING BRACKET • Maximum angle from vertical:5° • Electrical: 250 mAmps,12-125 VAC,50/60 Hz • Secures discharge pipe to basin wall. 500 mAmps,6-12 VDC,50/60 Hz • Clamps directly to 2"PVC discharge pipe. : • Housing and Float:1.60 inch diameter x 6.7 inch long (4.06 cm X 17.01 cm),high impact, corrosion resistant PVC for use in sewage and non-potable water up jCABEWEIG " `;` to120°F(so°c) Provides an accurate pivot point for suspended float switches. ttAtitelfrAINEIrMirarillie • • Gripper teeth on clip and weight channel securely 10 lb.weight li lock float cable into place • Yellow,vinyl coated,mushroom style t$ • Cable weight can be adjusted without the use of tools HOUSING:1 pound,5 ounce(0.6 kgs.), U.S.Patent 2.8 inch diameter x 3.3 inch long 5,306,885 mp m diameternt,nx n- om), rro impact resistant,noncorrosive, CHAIN 1111111111111111111. PVC housing for use in liquids up to 140°F(60°C) • 1/8"thickness CLIP:injection molded acetal plastic • 316 grade stainless steel • Available in one foot increments WIRE/CABLE ACCOMMODATED: SJOW,SJTW,18/2,18/3, 16/2,16/3,14/2 and 14/3 SHIP WEIGHT:1.6 lbs.(.726 kgs) _RACKET_ • Universal hanger for up to 6 float switches, submersible transmitters,and small 4 horsepower pump cords. •SJE RHOMBUS. • Hook males steel x 3.0" (1.8 mm x 76.2 mm) • 304 stainless steel 9sco:. 9ao 03/2l in 1 4z 2020 SJE,Inc_All Rights Reserved. SJE Rhombus is a trademark of SJE.Inc www.sjerhombus.com • Toll Free 888-342-5753 H.7 FLOAT ACCESSORIES-Cable Clamp Assembly, Float Brackets,Pipe Mounting Bracket,Cable Weights,ETM w/Piggy-Back Plug,Vertical Reed Switch,Anchor and Chain. Part# Description 1008569 18 8.16 Gauge Cable Clamp Assembly 1008574 14 Gauge Cable Clamp Assembly 1008575 12 Gauge Cable Clamp Assembly 1027830 304 Stainless Steel Float Bracket with 3 Black Cord Snubbers 1009432* 4 Float Bracket with Mounting Device 1009433 4 Float Bracket without Mounting Device 1009434 6 Float Bracket with Mounting Device 1009435 6 Float Bracket without Mounting Device 1009436 Float Bracket Mounting Device 1027771 Pipe Mounting Bracket 1002230* Cable Weight 1030356 Cable Weight Mini 1022846 Elapsed Time Meter w/120V Piggy-Back Plug 1032834 Elapsed Time Meter w/230V Piggy-Back Plug 1011027 10 foot Vertical Reed Switch 120V Box 1016561 15 foot Vertical Reed Switch 120V Box 1018687 10 lb.Mushroom Anchor 1018823 1/8 inch Chain 1052814 6 Hook Bracket *This item is an SJE Rhombus Quick Ship product which normally ships within 1 business day from receipt of order at no additional charge. California Prop 65 requires the following:®WARNING Cancer and Reproductive Harm-www.P65Wamings.ca.gnv H.8 www.sjerhombus.com•email:customer.service@sjeinc.com SEE PRICE BOOK FOR PRICING. SJE RHOMBUS Kennedy Swing Check Valves A.W.W.A. C508 was developed in 1976 to set a standard for the manufacture,testing and application of Iron Body Bronze Mounted (IBBM) Check Valves. The valves are designed with an iron body and include either metal-to- metal or composition-to-metal seating. Kennedy Swing Check Valves are designed and manufactured in conformance with A.W.W.A. C508 and are for use on water, oil and gas lines. Under certain circumstances where it is desirable to have more positive control of the closing of the disc, the valves can be supplied with either lever-and-spring or lever-and-weight. For restricted spacing requirements Kennedy Valve manufactures a Wafer Check Valve that also helps to control water hammer. Features Swing Check Valve-AWWA ."AIR • Stainless steel hinge pin. • Working parts are removable through the top of the valve. • Tapped bosses available. • Available with lever-and-spring or lever-and-weight. • Double bronze side plug construction. • Bodies are made of high strength cast iron with reinforced flanges-ANSI B 16.1/125 #flanges. • May be installed in a vertical line with the flow up. • Figure #1106 Series 2"-12" Test Pressure- Seat and Shell 400 PSI Working Pressure - non-shock CWP 200 PSI • Figure#106 Series 14•-24" Test Pressure- Seat and Shell 300 PSI Working Pressure - non-shock CWP 150 PSI FLOW VERSUS PRESSURE DROP Data Representative of Kennedy Figure 1106 and 1106A Swing Check Valves CHECKVALVEa2E 2 2.1 3 4 5 5 8 1012 1su 1820 24 10 f 3 4 � 2il o I 0.6 IISF 10 20 30 50 70 100 200 300 500 1000 2000 5000 10000 20000 40000 100000 Certified to FLOW ING.P.N. NSF/ANSI 61-G saes 2•-12' Updated 02/19/13 Kennedy Valve / Check Valves 15-1 • • AWWA SWING CHECK VALVES 211-12" TECHNICAL DATA & PARTS LIST Resilient/Bronze - Figure v 1106' 1106AW, 1106AS KENNEDY VALVE Bronze/Bronze - Figure# 1106, 1106LW, 1106LS uA Ve—BA 13A 111A 12AA IAA l ' 110A /YAH- FOR LBM1W 1, y' I 4w - IvV^ ' RESILIENT _ BRONZE 4IMIMMIMM �D � A TO SEATING e ASSEMBLY 1AB G 1>• (1106A,1106AW,1106AS) SA LEVER AND WEIGHT ASSEMBLY II sc/MAO IAA �,� 27A sAA 1A i1 Q"",-1A8 111144.41 1BAN 6. "I 21A _ " 1� 7AA_RBYWAYBB 2Aw 25A -"--SA to 12AB `7AB FOR L&1W 22A I 17A t -. �' �� 14A - . col, BRAlA R�pM ,4 c�\� SEATING .: i� •� ASSEMBLY 16Af� ue Iv --. (1106,1106LW,1106LS) Ep\ CAC —¢��� BAB LEVER AND SPRING 23A1 ,` 1106 ]_r- ASSEMBLY su NY1 i / a List kiI l" Below 22A 21A/ _VIM. Pert No. ON. Description Material 8 ASTM Spec. IA won 2 Side Plug Whit 0-Rog Bronze Disc Arrangement 2"-3" 1AB10-Ring) 1 for LS/LW 2A 'SEE FOOT NOTE Cap Bolts Stainless Steel.ASTM F593C 088) 3A 0-Ring Syn.Rubber 4A Cap Cast Iron.ASTM/1128 Clew B Cast Iron,ASTM A126 Class B �� 12AB SA 6A Body Cast Pin SS A-276(304) ©' BRONZE 7AA Hinge Bronze(2'-3--) \• 7AA DISC D.I.A-636(4'-te') ,A A. TAB Hinge wlkeyway for LS/LW Bronze(2.3-) •EJ•-N+ 7AB 13A Ductile Iron ASTM A530(4'-12') `�`�. BAA Disc son(4'-12') Bronze(4-I2') �` 11 L BAB Disc Bolt(4•n2') Bronze lzl(-B 12') �``AC 9AA Disc Boll 0-Ring(4'-12'1106A,8'-11-non) Syn.Rubber t` SAD 2 Disc Boa Gasket(4'8 a 11061 /, MA Disc Holder Bronze(2'3')'" ,r-'' '' 14A Cast Iron.ASTM A126 Cleat B(4'-12') 11A Dies Plate Bronze v`� 15A 12AA Disc NXHle(Bone N)Rubber • 12AB" Disc Bronze(2'-3')TT Cast Men.ASTM A126 Class B(4•-12-) 13A Disc Nut Stainless Steel,ASTM F693C(188) I wfresillent disc 12'-31 10A 14A" Disc Ring(4•-12')—(2•a•)"' Bronze 0 Q�, ,5A Seat Ring Bronze -/ 7AA RESILIENT 6A baton Steel .o a` `/ 7AB DISC 17A Extended Hinge Pin for LS/LW Stainless Steel,ASTMA-276(304) 11 A DISC I6A Keyfoe LSfLW Stainless Steel,ASTM A 2761304 a 19A Set Screw Stan �4 QQ/a•/ 20AA Lever Ann lor LS Stee ��it ,�-�' 20AB Lever Armlar LW Sloe �`)1V4 i�A/� 13A 21A Bracket Stee e'✓1� / 22A Hex Head Bracket Boll Stee Q� �b 23A Eye Bolt w/2 Hex Nuls Ste: 0.IN... 12AA 24A stuffing sox Bronze oY. 25A Packing Graphite Filled 4\ t 1SA 26A 1 Gland Bronze 27A 1 Weight Cast Iron.ASTM A126 Class 23A 1 Sal Screw Steel •Oty of cover bolts.2,M=4 bolts.IO-12-=0 boas. "Denotes that part is available only as pad elan assembly. "'Cast integral(2'-31. Updated 02/19/13 Kennedy Valve! Check Valves 15-3 Dimensional Data 2 "-12" 1106/1106LW/106LS FIG. 1106LW SHOWN. SAME DIMENSIONS t EDP -»I APPLY TO 1106 AND 1106LS l aiaaiai, if D v.: A DETAIL LW/LS :\ Ibl .,,,,„ IF 1, ; R /s\`�" C �S� I a DtA J A B L-BOLT CIRCLE DIA.END FLANGES M-NO.OF BOLTS PER FLAT END FLANGES N-BOLT HOLE DIA. END FLANGES CONFORM TO ANSI 816.1 'A B C D E F G H J L M N R SIZE inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm 2" 8.00 203 0.65 17 6.00 152 6.00 152 6.56 167 6.50 165 4.72 120 0 50 13 0.34 9 4.75 121 4 102 0.75 19 10.00 254 2 112- 8.50 216 0.69 18 7.00 178 6.44 164 6,56 167 6.50 165 4.94 125 0.50 13 0.41 10 5.50 140 4 102 0.75 19 8.00 203 3- 9.50 241 0.78 20 7.50 191 6.85 174 6.56 167 6.50 165 5.34 136 0.50 13 0.44 11 5.00 152 4 102 0.75 19 8.00 203 CZ)11.50 292 1.00 25 9.D0 229 8.69 221 9.00 229 7.75 197 8.19 208 0.62 16 0.41 10 7.50 191 8 203 0.75 19 12.00 305 6" 14 00 356 1.03 26 11 A0 279 10.51 267 11.00 279 9.75 248 9.00 229 0.75 19 0.43 if 1 9.50 241 8 203 0.87 22 15.00 381 8" 19.50 495 1.25 32 13.50 343 12.56 319 13.50 343 14.13 359 10.18 259 0.87 22 0.75 19 '1.75 298 8 203 0.87 22 15.00 381 10" 24.50 622 1.31 33 16.00 406 14.07 357 16.15 425 18.00 457 11.62 295 1.00 25 0.81 21 14.25 362 12 305 1.00 25 15.00 381 12" 27.50 699 1.38 35 19.00 483 16.13 410 19.00 483 18.00 457 13.75 349 1.00 25 0.87 22 17.00 432 12 305. 1.00 25 15.00 381 BODY MARKINGS (ONE SIDE) I (OPPOSITE SIDE) A.W.W.A. FIG.NO. KENNEDY 200 W CAP MARKINGS YEAR KENNEDY SIZE BOSS AND DRAIN TAPPING SCHEDULE == A B VALVE SIZE (In.) 2-31/2 4-5 6 8,10,12 MAX. SIZE A I 1 I!! B C 1 DPIPE TAP(NPT) 3/a 1 1V4 2 When ordering Check Valves tapped for by- . C... .._i .. IIPI pass or drain, specify exact location and size �" of tap using letters above for boss designation. ` These locations of drain and by-pass tappings conform to the Manufacturers Standardization C D E F Society(MSS SP-45 current edition). G 15-4 Kennedy Valve/ Check Valves Updated 02/19/13 GASKET MATERIAL SPECIFICATIONS RUBBER SHEET PRODUCTS: COMMERCIAL NEOPRENE COMMERCIAL BUNA WHITE FDA NITRILE GOOD OIWCAS RESIST GOOD RESISTANCE TO OILS GOOD FOR ALL TYPES GOOD FOR BUMPERS, &AROMATIC FUELS OF FOOD PROCESSING SUPERIOR CHEMICAL PHARMACEUTICAL AND COSMETIC APPLICATIONS: PADS&SEALING,RESISTS RESISTANCE PRODUCTS RESISTANT TO OILY ROT,CHECKING&CRACKING GOOD RESISTANCE TO &GREASY FOODS,NON-TOXIC BOTH OIL&WATER NON-MARKING,NON-ALLERGENIC COLOR BLACK BLACK WHITE THICKNESS(INCHES): 1/32-2 1/32-1 1/16-1/4 DUROMETER HARDNESS/SHORE A+1.5:__ 60 60 _..._. 60 TENSILE: 1300 900 1000 ELONGATION: 500 300 650 TEMPERATURE MAX: 170 F 170 F 220 F WEIGHT PER LINEAL FOOT(36"WIDE): 1/8-2.7 1/8-2.6 1/8-2.8 FINISH: SMOOTH SMOOTH SMOOTH SPECIFICATIONS: -ASTM D-2000-86e -ASTM D-2000.86e FDA APPROVED/NON-TOXIC -SAE 1200,1 BC 609 -SAE 1200,1 BE 609 NON-ALLERGENIC/NON-MARKING -MIL R-3065,SC 609 GOOD OIL RESISTANCE ____a6 RED RUBBER _ COMMERCIAL EPDM CLOTH INSERTED RUBBER APPLICATIONS.- RECOMMENDED FOR LOW EXCELLENT FOR EXTREME PRESSURE—HEATING& TEMP/WEATHER PLUMBING(LOW COST) OZONE&CHEMICAL RESIST. EXCELLENT FOR AIR,HOT&COLD WATER, AGING,ABRASION& EXCELLENT ELECTRICAL TEAR RESISTANCE &DYNAMIC PROFS SATURATED STEAM,LOW PRESSURE HYDRAULIC CONFORMS TO UNEVEN EXCELLENT RESISTANCE TO -EXCELLENT FOR CUSTOM CUTTING FLANGE SURFACES HIGH TEMP,ANIMAL&VEG OILS,STEAM& &OFF-SIZE APPLICATIONS OXYGENATED SOLVENTS COLOR: RED BLACK BLACK THICKNESS(INCHES): 1/8-3.5 1/16-1/4 1/16-1/4 DUROMETER HARDNESS/SHORE A+1-! 75 60 65 TENSILE: 600 1000 400 ELONGATION: 200 500 200 TEMPERATURE MAX: 170 F 220 F 170 F WEIGHT PER LINEAL FOOT(36"WIDE) 1/8-3.5 1/8-22 N/A FINISH: FABRIC FINISH SMOOTH SMOOTH SPECIFICATIONS: ASTM D-1330-66 -ASTM D-2000-860 FABRIC WEIGHT:4 OZ CLASS II SAE 1200,IBA(608,708),C12 FABRIC TYPE:POLYESTER ASTM D-2000 -MIL R-3065 OIL RESISTANCE:NONE _ TYPE AA -RS608,C12 SPECIALTY SHEET PRODUCTS: SOFT-CHEM GRAPHOIL EXCELLENT RESISTANCE -ASBESTOS-FREE,NO FIBERS, , IIIIS it/ 0 CJJARACTERISJICS& TO CHEMICALS,MOSTLY BINDERS OR ADDITIVES \ 1, APPLICATIONS. UNAFFECTED BY STEAM IMPERMEABLE TO GASES FIBROUS STRUCTURE &LIDQUIDS,RESISTS THERMAL LAIN BOLT&GASKET,INC HIGH COMPRESSIBILITY SHOCK,EXC.SEALABHATY EXCELLENT CORROSION DOES NOT AGE,SHRINK RESISTANCE OR HARDEN,HIGHLY &IMPERMEABILITY CHEMICAL RESISTANT HOMOGENEOUS TANG INSERTED(316SS) CREEP ASTM F38B 212 F: 35%(1/32") 0.05 0.1 SFALABILITY ASTM F37B FUEL A: 002 ml/min -- — GAS LEAKAGE DIN 3535/6: .02 mVmin --- -- HOT COMPRESSION: THICKNESS DECREASE AMBIENT 3625 psi 37% -- — THICKNESS DECREASE 572 F 29% -- -- COMPRESSIBILITY ASTM F367: 60% 45%(5000 pai) 35%(5000 psi) RECOVERY ASTM F36A: 12%min 20%(5000PSI) 18%(5000psi) TENSILE AS1M 152: 1500 psi 700 PSI 5000 psi VACUUM TO FULL PRESSURE: 3000 osi -- -- CHEMICAL RESISTANCE: 0-14 ph 0-14 ph 0-14 ph DENSITY: .85 g/cm3 62.4 lbs/B3 62.4 lb/R TEMPERATURE MAX: 500 F 900 F(in air) 900 F(in air) 1200 F(in steam) 1800 F(inert media) PRESSURE MAX: 3000 psi 2000 psi 2000 psi TESTED BY ECOLE POLYTECHNIC(1/16"}: , Gb psi 1260 98%minimum CARBON 98%minimmn a 0.2 1200ppmmax LBACIIABI CIRAS ULFURIDBS 1203 ppm max GS psi 3.5 50 pop max 50 ppm max CAIN BOLT GASKET,INC TECHNICAL MANUAL GASSPEC.XLS t 0 CAIN BOLT&GASKET,INC [OLD STANDARD/NEW STANDARD PIPING GASKET SPECS/RINGS,FULL FACE 125 150#RING 125-150#FULL FACE 1 _ PIPE Slg PIPE SIZE NEW STD.ASA B OLD STD. NEW STD.ASAI.D. &OLD STD. LD. XO.D. 1.0. LO.XO.D. NO. DIA. BOLT HOLES HOLES CIRCLE 1/2 27/32 X 1-7/8 1/2 27/32 X 3-1/2 4 5/8 2-3/8 3/4 1-1/16 X 2-114 3/4 1-1/16 X 3-7/8 4 5/8 2-3/4 1 1-5/16 X 2-5/8 1 1-5/16 X 4-1/4 4 5/8 3-1/6 1-1/4 1-21/32 X3 1-1/4 1-21/32 X 4-5/8 4 5/8 3-1/2 1-1/2 1-29/32 X 3-3/8 1-1/2 1-29/32X 5 4 5/8 3-7/8 2 2-3/8 X 4-1/8 2 2-3/8 X 6 4 3/4 4-3/4 2-1/2 2-7/8 X 4-7/6 2-1/2 2-7/8 X 7 4 3/4 5-1/2 3 3-1/2 X 53/8 3 a-1l X 7.1/3 ?/d 6 4 4-112 X 6.7/8 4 4-1/2 X 9 I I 3/4 7-1/2 I 5 5-9/16 X 7-3/4 - 6 8 //8 6-1IL 6 6-5/8 X 8-3/4 6 6-5/8 X 11 8 7/8 9-1/2 8 8-5/8 X 11 8 85/8 X 13-1/2 8 7/8 11-3/4 p W 10 10-3/4 X 13318 10 10-314 X 16 12 1 14-1/4 Q II 12 12-3/4 X 18-1/8 12 12314 X 19 12 1 17 Ll p I 14 14 X 173/4 14 14 X 21 12 1-1/8 18-3/4 H¢ 16 18 X 20-1/4 18 16 X 23-1/2 16 1-1/8 21-1/4 be p SO18 18 X 215/8 18 18 X 25 16 1-1/4 22-3/4 v p 20 20 X 23-7/8 20 20 X 27-1/2 20 1-1/4 25 O O 22 22 X 26 22 22 X 29-1/2 20 1-1/4 27-1/4 p 24 24 X 28-1/4 24 24 X 32 20 1-3/8 29-1/2 Ili y 26 28 X 30-1/2 26 26 X 34-1/4 24 1-3/8 31-3/4 O 3 28 28 X 32-3/4 28 28 X 38-1/2 28 13/8 34 30 30 X 34-3/4 30 30 X 38-3/4 28 1-3/8 36 2 2 32 32 X 37 32 32 X 413/4 28 1-5/8 38-1/2 34 34 X 39 34 34 X 43-3/4 32 1-5/8 40-1/2 36 36 X 41-1/4 36 36 X 46 32 1-5/8 42-3/4 38 38 X 43-5/8 38 38 X 48-3/4 36 1-5/8 45-1/4 40 40 X 45-5/8 40 40 X 50-3/4 36 1-5/8 47-1/4 42 42 X 48 42 42 X 53 36 15/8 49-1/2 44 44 X 50-118 44 44 X 55-1/4 40 1-5/8 51-3/4 46 46 X 52-1/8 46 46 X 57-1/4 40 1-5/8 53-3/4 48 48 X 54-112 48 48 X 59-1/2 44 1518 56 250-300#RING 250-300#FULL FACE PIPE SIZE 95_3[7�I�.LD. OLD STD. O NEW STD.ASA I.D. NEW STD.ASA ID. NO. DIA. BOLT I.D.X O.b. x O.D. HOLES HOLES CIRCLE 1/2 27/32 X 2-1/8 1/2 27/32 X 3-3/4 4 5/8 2-5/8 3/4 1-1/16 X2-5/8 314 1.1/16X4.5/8 4 3/4 3-1/4 1 15/16 X 2-7/8 1 15/16 X 4-7/8 4 3/4 3-1/2 O N 1-1/4 1-21/32 X 3-1/4 1-1/4 1-21/32 X 5-114 4 3/4 3-7/8 p 11/40 ill 1-1/2 1-29/32 X 3314 1-1/2 1-29/32 X 6-118 4 7/8 4 1/2 O E 2 2-3/8 X 4-3/8 2 2-3/8 X 6-112 8 3/4 5 "I CZ 2-1/22-7/8 X 5-1/8 2-12 2-7/8 X 7-12 a 7/8 5-7/8 O y ti 3 3-12 X 5-7/8 3 3-1/2 X 8-1/4 8 7/8 6-5/8 WIll 4-12 X 7-1/8 4 4-1/2 X 10 8 7/8 7-7/8 OF 5 5-9/16 X 8-12 5 5-9116 X 11 8 7/8 9-1/4 C5 118 6 6-5/8 X 9-7/8 6 6-518 X 12-1/2 12 7/8 10-5/8 2 2 8 8-5/8 X 12-1/8 8 8-5/8 X 15 12 1 13 4 10 10-3/4 X 14-1/4 10 10-3/4 X 17-1/2 16 1-1/8 15-1/4 12 12-3/4 X 16-5/8 12 12-3/4 X 20-1/2 16 1-1/4 17-3/4 14 14 X 19-1/8 14 14 X 23 20 1-1/4 20-1/4 16 16 X 21-1/4 16 16 X 25-1/2 20 1-3/8 22-1/2 19 18 X 23-12 18 18 X 28 24 1-3/8 24-3/4 20 20 X 25-3/4 20 20 X 30-1/2 24 1-3/8 27 22 22 X 27-3/4 22 22 X 33 24 1-3/8 29-1/4 24 24 X 30-1/2 24 24 X 36 24 1-518 32 26 26 X 32-7/8 26 26 X 38-1/4 28 1-5/8 34-1/2 28 28 X 35-3/8 28 28 X 40-3/4 28 1-5/8 37 30 30 X 37-1/2 30 30 X 43 28 1-7/8 39-1/4 32 32 X 39-5/8 32 32 X 45-1/4 28 1-718 41-12 34 34 X 41-5/8 34 34 X 47-1/2 28 - 1-7/8 43-1/2 36 36 X 44 36 36 X 50 32 2-1/8 46 38 38 X 46-1/8 38 38 X 52-1/4 32 2.1/8 48 40 40 X 48-3/4 40 40 X 54-1/4 36 2-1/8 50-1/4 42 42 X 50-3/4 42 42 X 57 36 2-1/8 52-3/4 44 44 X 53 44 44 X 59-1/4 36 2-1/8 55 46 46 X 55-1/4 46 46 X 61-1/2 40 2-1/8 57-1/4 48 48 X 58-3/4 48 48 X 65 40 2-1/8 60-3/4 ASTM A563 GR A HEX & HEAVY HEX NUT CARBON STEEL MECHANICAL PROPERTIES GRADE NOMINAL SIZE STYLE OF PROOF LOAD STRESS, KSI HARDNESS NUT NUTS WITH NON ZINC COATED ZINC-COATED BRINELL ROCKWELL UNC,8 UN,6 NUTS NUTS MIN MAX MIN MAX UN AND COARSER PITCH THREADS A Y TO 1-1/2 HEX 90 68 116 302 B68 C32 A ''A TO 4 HEAVY HEX 100 75 116 302 868 C32 CHEMICAL PROPERTIES �-� ELEMENT HEAT PRODUCT CARBON % 0.55 MAX 0.58 MAX MANGANESE % PHOSPHORUS % 0.12 MAX 0.13 MAX SULFUR % 0.15 MAX SULFUR CONTENT OF 0.23%MAX IS ACCEPTABLE WITH THE PURCHASERS APPROVAL A563 GR A NUTS ARE INTENDED FOR USE ON GENERAL STRUCTURAL AND MECHANICAL BOLTS,STUDS,AND OTHER EXTERNALLY THREADED PARTS.A563 GR A NUTS ARE SUPPLIED IN A HEX OR HEAVY HEX PATTERN PER ASME B18.2.2 STANDARD FOR SQUARE AND HEX NUTS.A563 GR A NUTS ARE NORMALLY USED WITH A307A AND A307B BOLTS AND STUDS. NOTE:PROPERTIES AND APPLICATION PARAMETERS ARE TYPICAL AND ARE PRESENTED IN GOOD FAITH BUT NO WARRANTY/S EXPRESSED OR IMPLIED. HD Fowler Submittal Package • Fought & Company Z Tigard , OR "Low Flow >1" Submersible Pump" a 18 Pages 0 ce W rm.J FOR: BY: 0 McKillip Excavation Inc H.D. Fowler �• PO Box 585 Chris Moore • Donald, OR 28800 SW Boberg Road • ** Sam McKillip ** Wilsonville, OR 97070 H.D. FOWLER COMPANY BELLEVUE,WA • BELLINGHAM,WA • BOISE,ID • BOZEMAN,MT • BREMERTON,WA EUGENE,OR • HAYDEN,ID • HERMISTON,OR • IDAHO FALLS,ID • JACKSON,WY MARYSVILLE,WA • MEDFORD,OR • OLYMPIA,WA • PACIFIC,WA • PASCO,WA REDMOND,OR • SPOKANE,WA • TWIN FALLS,ID • VANCOUVER,WA WENATCHEE,WA • WILSONVILLE,OR • YAKIMA,WA HD Fowler Note: Low Flow Submersible Pump TECHNICAL BROCHURE BLSPO3 Ti ...Ns l .\ �couios � —a mp vuTp *If' M LSPO3AT z>F LSPO3AV Sump pump s , 1 LSPO7 LSPO3 / LSPO7 SUBMERSIBLE SUMP PUMPS GOULDS a xylem brand HD Fowler Note:Low Flow Goulds Water Technology Wastewater Submersible Pump FEATURES Corrosion-resistant construction Complete unit is lightweight,portable and easy to Stainless Steel motor casing and fasteners service. Glass filled thermoplastic impeller and casing. Available in manual and automatic versions.See next page for specific order numbers. Upper and lower heavy duty ball bearing A double labyrinth lip seal system protects the construction. motor.It consists of three lip seals and a V-ring in Motor is permanently lubricated for extended addition to an impeller counterblade system which service life and is powered for continuous keeps solid particles away from the seal unit. operation.All ratings are within the working limits of the motor. AGENCY LISTINGS Hard coated 400 series stainless steel shaft for Canadian Standards Association improved corrosion resistance. File#LR114251 c us Float switch is adjustable for various liquid levels. Easily removed for direct pump operation or switch Underwriters Laboratories replacement. File#83318 APPLICATIONS MOTOR Specially designed for the following uses: •Single phase,3450 RPM,60 Hz • Basement draining • LSP03, '/3 HP, 115 V,2.9 maximum amps •Water transfer • LSP07,34 HP, 115 V(7.1 amps)or 230 V(3.5 amps) • Dewatering • Built-in thermal overload protection with automatic reset. SPECIFICATIONS • Permanent-split-capacitor type • Discharge size: 1 'h" NPT • Class B insulation •Capacities:to 57 GPM • Stainless steel shaft • Maximum head: 34 feet TDH •Air filled design • Maximum solids: 3/a"spherical • Power cord length: LSP03; 10 feet standard,20 feet •Temperature: 104°F(40°C)maximum liquid optional, LSP07; 20 feet. temperature. FLOAT SWITCH OPTIONS • Maximum pump submergence is 10 ft.for LSP03;16 ft.for LSP07. • Models are available with a float switch.Several options for automatic operation. •"AV"models are supplied with a vertical float switch. •"A" models are supplied with a built in float switch. • "AT" models are supplied with a piggy-back replaceable float switch. PAGE 2 -"° Fowler Flow : Low Flow Goulds Water Technology Wastewater Submersible Pump FEET MODEL: LSP03, LSPO7 SIZE: 3/8" SOLIDS MAX. 35 RPM: 3450 HP: 1/3 and 3/4 LSPO7 30 `p 25 I ! U I Q 20 LSP03 z 0 Q 15 O I- 10 5 00 10 20 30 40 50 GPM CAPACITY MODEL INFORMATION Minimum Float Switch Cord Discharge Min. Min. Minimum Maximum Shipping Order No. HP Volts Amps Circuit Phase Style Length Connection On Off Basin Solids Weight Breaker Level Level Diameter Size Ibs/kg LSP0311 Plug/No Switch Manual Manual 9" LSP0311A Built-In Wide 11" 5" 12" Angle LSP0311AT Piggyback Wide 11" 5" 12" Angle LSP0311AV % 115 2.9 Piggyback 8.5 Vertical " 2" 12" i:C LSP0311 F Plug/No Switch Manual Manual 9" LSP0311AF Built-In Wide 11" 5" 12" Angle 20' LSP0311ATF 10 1 Piggyback Wide WO 11" 5" 12" SO Angle LSP0711 F Plug/No Switch Manual Manual 9" LSP0711AF Built-In Wide 12 5" 6.5" 12" 115 7.1 Angle LSP0711 ATF Piggyback Wide 12.5" 6.5" 12" Angle 44 20' 15/6.8 LSP0712F Plug/No Switch Manual Manual 9" Built-In Wide LSP0712AF 12.5" 6.5" 12" 230 3.5 Angle LSP0712ATF Piggyback Wide 12.5" 6.5" 12" Angle PAGE 3 HD Fowler Note: Low Flow j Submersible Pump DIMENSIONS I (All dimensions are in inches.Do not use for construction purposes.) F H LSPO3 9Y4 7% '.-= LSPO7 1114 9% LSPO3AV 93/4 7% POWER CORD: 16/3 SJTW WITH THREE AN GROUNDING PLUG 616"DIA. IT Tfti3 _r 1'h"NPT --1 10; RIP i _..'I A DISCHARGE INN .,— F F LSP03AV 12" Illi— H �� N r rl I______u� ___�IIII' EN 11 ■ ■ 1.1 v v xylem Xylem,Inc. Let's Solve Water 2881 East Bayard Street Ext.,Suite A Seneca Falls,NY 13148 Phone:(866)325-4210 Fax:(888)322-5877 www.xyleminc.com/brands/gouldswatertechnology Goulds is a registered trademark of Goulds Pumps,Inc.and is used under license. C 2012 Xylem Inc. BLSPO3 RI April 2012 HD Fowler Note: Optional Low Flow Submersible Pump IibffjPump s Pump Specifications 250-Series Submersible Sump / Effluent Pump LITERS PER MINUTE 0 20 40 60 80 100 120 140 160 160 25 4I I I I 1 I 7 20 6 5 15 04 w I I- w f w — 4 z z o o a = W = J Q Q FO 10 3 - 2 5 - 7 0 10 20 30 40 50 GALLONS PER MINUTE Libel* 250_P1 RI/17/2018 ()Copyright 2018 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. Pumps HD Fowler Note: Optional Low Flow Submersible Pump 250-Series Dimensional Data . ......_.__.. 9.5in [240mm] P1 III 1""iceS.Sin ��tc*lic_,' ).1-"N\ � [165mm] J MANUAL VERSION PIGGY BACK 115V CORD AUTOMATIC VERSION Ii ) imil pima' p 11 Kr ] I -='--7."--- —T--.--..- Mil -7 1 10.7in IIIIl— 0 1 — IIII,rii o awlme 3.Oin rr� F_MIDN[I4R ,i, rr� �II_Imd li11■ e [77mm] —'1ii■ w I vbe't,`.'�' Pumps PROAFMART ANO CONFIDE/AIM THE NFORMAIION CONTAINED N TH6 DRAWING 6THE SOLE PROPERTY OP _ND. 250 SERIES DIMENSIONAL MERIT PUMPS.ANY REPRODUCTION IN PART OR AS A WHOLE WRHOUF NE WRMEN PE7M651ON OP Maar PUMPS DATE:OCTOBER/2015 6 PROHIEDFD. APPLICATION DO NOT SCALE DRAWING scALeIH I WEIGHT: 23 LB$ 1nHsrlal 250_P2 RI/17/2018 CCopynght 2018 Liberty Pumps Inc. All rights reserved. Specifications subject to change without entice. 1610 HD Fowler Note: 1 Optional Low Flow ''' Submersible Pump 250-Series Electrical Data FULL LOCKED THERMAL STATOR CORD MODEL HP VOLTAGE PHASE LOAD ROTOR OVERLOAD WINDING LENGTH DISCHARGE AUTOMATIC AMPS AMPS TEMP CLASS FT 250 1/3 115 1 5.2 8 105°C/221°F B 10 11/2 NO MANUAL YES 251 1/3 115 1 5.2 8 105°C/221°F B 10 1 1/2 INTEGRAL FLOAT YES 253 1/3 115 1 5.2 8 1O5C/221°F B 10 11/2 PIGGYBACK FLOAT YES 257 1/3 115 1 5.2 8 105C/221°F B 10 11/2 INTEGRAL VERTICAL FLOAT 250-Series Cord Length Options* Model 10' 25'(-2) 35'(-3) 50'(-5) 250 Standard Optional Optional Optional 251 Standard Optional Optional Optional 253 Standard Optional Optional N/A 257 Standard Optional N/A N/A 10' cord length standard on all models. For optional lengths, add "-2, - 3 or-5" suffix to model number. Example: for model 250 with 35' cord. Order 250-3 WARNING: *Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty Pumps product. Using a cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other significant failure. 250 P3 RI/17/2018 cCopyright 2018 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice_ HD Fowler Note: Optional Low Flow Submersible Pump 250-Series Technical Data VORTEX IMPELLER ENGINEERED POLYMER SOLIDS HANDLING SIZE ��rt PAINT POWDER COAT MAX LIQUID TEMP 60°C 140'F CLASS B MAX STATOR TEMP 130°C/266°F THERMAL OVERLOAD 105°C/221°F SJTW(10 ft&25 ft models) POWER CORD TYPE SJTOOW(35 ft&50 ft models) MOTOR HOUSING I VOLUTE CLASS 25 CAST IRON SHAFT STAINLESS HARDWARE STAINLESS 0-RINGS BUNA N ENGINEERED DOUBLE LIP SEAL SEAL WITH STAINLESS STEEL SPRINGS WEIGHT 23 LBS. 250-Series Specifications 1.01 GENERAL: The contractor shall provide labor,material,equipment,and incidentals required to provide (QTY)centrifugal pumps as specified herein.The pump models covered in this specification are 250-Series single phase pumps.The pump furnished for this application shall be model as manufactured by Liberty Pumps. 2.01 OPERATING CONDITIONS: Each submersible pump shall be rated at 1/3 hp, 115 volts,single phase,60 Hz.,3450 RPM.The unit shall produce GPM at feet of total dynamic head. The submersible pump shall be capable of handling effluent with 1/2"solid handling capability.The submersible pump shall have a shut-off head of 23 feet and a maximum flow of 44 GPM @ 5 feet of total dynamic head. The pump shall be controlled with: A piggyback style on/off float switch. An integrally wired on/off float switch. A Vertical Mechanical Float(VMF)type on/off switch. A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm. A NEMA 1 indoor simplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor simplex control panel with four float switches and a high water alarm. A NEMA 1 indoor simplex control panel with four float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm. 250_P4 RI/17/2018 ®Copyright 2018 Liberty Pumps Inc. All rights reserved. Specifications subject to change without rotice. uha L' Pumps HD Fowler Note: Optional Low Flow Submersible Pump A NEMA 1 indoor duplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm. A NEMA 1 indoor duplex control panel with four float switches and a high water alarm. 3.01 CONSTRUCTION: Each centrifugal effluent pump shall be equal to the c�us certified 250-Series pumps as manufactured by Liberty Pumps, Bergen NY.The castings shall be constructed of class 25 cast iron.The motor housing shall be oil filled to dissipate heat.Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor.All mating parts shall be machined and sealed with a Buna-N 0-ring.All fasteners exposed to the liquid shall be stainless steel.The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord.The motor shall be protected on the lower side with an engineered double lip seal with stainless steel springs. The pump shall be furnished with stainless steel handle. 4.01 ELECTRICAL POWER CORD The submersible pump shall be supplied with 10,25,35,or 50 feet of multiconductor power cord.It shall be cord type SJ1W,or SJTOOW capable of continued exposure to the pumped liquid.The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code.The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly,with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord,by means of a damaged or wicking cord. 5.01 MOTORS Single phase motors shall be oil filled,permanent split capacitor,class B insulated NEMA B design,rated for continuous duty.At maximum load the winding temperature shall not exceed 130 degrees C unsubmerged.Since air filled motors are not capable of dissipating heat they shall not be considered equal.The pump motor shall have an integral thermal overload switch in the windings for protecting the motor.The capacitor circuit shall be mounted internally in the pump. 6.01 BEARINGS AND SHAFT Upper and lower ball bearings shall be required.The bearings shall be a single ball/race type bearing.Both bearings shall be permanently lubricated by the oil,which fills the motor housing.The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.311". 7.01 SEALS The pump shall have an engineered double lip seal with stainless steel springs.The motor plate/housing interface shall be sealed with a Buna-N 0-ring. 8.01 IMPELLER The impeller shall be engineered polymer,with pump out vanes on the back shroud to keep debris away from the seal area. It shall be threaded to the motor shaft. 9.01 CONTROLS All pumps can be supplied with a CSA and UL approved VMF type switch,an integrally wired wide angle tilt float switch,or piggyback type wide angle tilt float switches.The piggyback style switches are equipped with a plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable.Manual pumps are operable by means of a pump control panel. 250_P5 RI/17/201 S ®Copyright 2018 Liberty Pumps Inc. All rights reserved Specifications subject to change without notice. Yam* Pumps HD Fowler Note: Optional Low Flow Submersible Pump 10.01 PAINT The exterior of the casting shall be protected with Powder Coat paint. 11.01 SUPPORT The pump shall have cast iron support legs,enabling it to be a free standing unit. 12.01 SERVICEABILITY Components required for the repair of the pump shall be shipped within a period of 24 hours. 13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile grommets or 0-rings.Discharge piping shall be schedule 80 PVC and furnished with a PVC shut-off ball valve.The Tank shall be wound fiberglass or roto-molded plastic.An inlet hub shall be provided with the fiberglass systems. Stainless steel Guide Rail Zinc plated steel Guide Rail "diameter of basin size "height of basin size "distance from top of tank to discharge pipe outlet Fiberglass cover Structural foam polymer cover Steel cover Simplex System with Outdoor panel and alarm Duplex System with Outdoor panel and alarm Separate Outdoor Alarm Remote Outdoor Alarm 14.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity,moisture content and insulation defects.The motor and volute housing shall be pressurized,and an air leak decay test is performed to ensure integrity of the motor housing.The pump shall be run,voltage current monitored,and the tester checks for noise or other malfunction. 15.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified facility. 16.01 WARRANTY Standard limited warranty shall be 3 years. 250 P6 R1/17/2018 ®Copyright 2018 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. Pumps- SENSOR FLOAT° MINI Control Switch Mercury activated,narrow-angle float switch designed to activate pump control panels and alarms. This narrow-angle sensing device is used to accurately monitor liquid levels in confined sewage and non- potable water applications.The Sensor Float®Mini control switch is not sensitive to rotation. Normally Open Model(high level) 11111 The control switch turns on (closes)when the float tips slightly above horizontal signaling a high level, and turns off(opens)when the float drops slightly below horizontal. Normally Closed Model(low level) -- The control switch turns on (closes)when the float drops slightly below horizontal signaling a low level, and turns off(opens)when the float tips slightly above horizontal. If g Contact SJE-Rhombus regarding intrinsically safe applications. FEATURES SPECIFICATIONS I Designed for use in confined spaces. CABLE:flexible 18 gauge,2 conductor(UL, CSA)SJOW,water-resistant(CPE) I Not sensitive to rotation. jacket / Control differential of.5 inches(1 cm)above or below horizontal. FLOAT: 2.81 inch diameter x 3.42 inch / UL Listed for use in non-potable water and sewage. long (7.14 cm x 8.68 cm), high impact, corrosion resistant PVC housing for use / CSA Certified. in sewage and non-potable water up to I Three-year limited warranty. LR54245 LISTED 140°F (60°C) 83N2 YGI�l. MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi OPTIONS MERCURY TILT SWITCH: single pole, single throw, mercury-to-metal contacts, This switch is available: hermetically sealed in a steel capsule and epoxy sealed in the float housing I for normally open(high level)applications or normally closed (low level)applications. ELECTRICAL: 5 amp, 120/230 VAC, 50/60 Hz / in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters(longer lengths available). This switch is not recommended for / with two mounting options that allow for flexibility in installation: controlling: I electric loads less than 30 Mounting Clamp: for applications where the switch can be milliamps, 12 VAC attached to a discharge pipe or similar mounting device. I non-arcing electric loads .. Externally Weighted:for applications where the switch can be (intrinsically safe applications) suspended from above. SE RhtlniDus. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE• 1-218-847-1317 1-218-847-4617 Fax SEE BACKSIDE FOR ORDERING INFORMATION. email: sje@sjerhombus.com SEE PRICE BOOK FOR LIST PRICE. WWW.sjerhombus.com 115 • SENSOR FLOAT° Mini Control Switch Mercury activated, narrow-angle float switch designed to activate pump control panels and alarms. ORDERING INFORMATION Normally Open Normally Closed OPTIONS Shipping Part # Description Part# Description Weight PACKAGING 1002181 10MPCNO 1002184 10MPCNC 1.20 lbs. Bagged -ptandard Boxed-optional 1002206 10MWENO 1002209 1OMWENC 3.18 lbs. Bulk-optional No Mounting- deduct optional 1002187 15MPCNO 1002190 15MPCNC 1.57 lbs. 1002212 15MWENO 1002215 15MWENC 3.41 lbs. ADDITIONAL CABLE Additional cable length over 30 feet is available. 1002193 20MPCNO 1002196 20MPCNC 1.90 lbs. 1002218 20MWENO 1002221 20MWENC 3.74 lbs. UL Listed for Water&Sewage 1002199 3OMPCNO 1002202 30MPCNC 2.68 lbs. 1002224 30MWENO 1002227 3OMWENC 4.56 lbs. LISTED LR54245 PC=Pipe Clamp WE=Weighted Externally NO= Normally Open NC=Normally Closed 83N2 NOTE: Descriptions are grouped by cable length measured in feet(10, 15, 20, 30). SEE PRICE BOOK FOR LIST PRICE. SPECIFICATIONS OTHER INFORMATION CABLE:flexible 18 gauge, 2 conductor(UL, CSA) SJOW,water-resistant NORMALLY OPEN(HIGH LEVEL) (CPE)jacket OPERATION FLOAT: 2,81 inch diameter x 3.42 inch long(7.14 cm x 8.68 cm), high impact, The control switch closes (turns on)when corrosion resistant PVC housing for use in sewage and non-potable signalinghe float tips slightly above horizontal = a high level, and opens(turns water up to 140°F (60°C) off)when the float drops slightly below g MAXIMUM WATER DEPTH:30 feet(9 meters), 13 psi horizontal. O MERCURY TILT SWITCH: single pole, single throw, mercury-to-metal NORMALLY CLOSED(LOW LEVEL) contacts, hermetically sealed in a steel capsule and epoxy sealed in OPERATION the float housing The control switch closes(turns on)when Z ELECTRICAL: 5 amp 120/230 VAC, 50/60 Hz the float drops slightly below horizontal 8signaling a low level, and opens(turns This switch in not recommended for controlling: off)when the float tips slightly above / electric loads less than 30 milliamps, 12 VAC horizontal. / non-arcing electric loads NOTE: Contact SJE-Rhombus regarding intrinsically safe applications. S E Rh USw Call or fax your order! www.sjerhombus.com 1-888-DIAL-SJE (1-888-342-5753) / Fax 218-847-4617 sje@sjerhombus.com Cat Page PN 516P 116 c�SJE Rhombus12 06/11 TANK ALERT° XT Alarm System Versatile,indoor or outdoor liquid level alarm system. This alarm system monitors liquid levels in lift pump chambers,sump pump basins,holding tanks, sewage,agricultural,and other water applications. The Tank Alert'XT indoor/outdoor alarm can serve as a high or low level alarm depending on the float - switch model used. • The alarm horn sounds and the red beacon illuminates when a potentially threatening liquid level condition occurs.The horn can be silenced, but the alarm light remains on until the condition is remedied.Once the condition is cleared,the alarm will automatically reset. A"power on"light on the switch indicates power to the alarm panel. FEATURES SPECIFICATIONS • Enclosure meets Type 3R water-tight standard. VOLTAGE:120 VAC,50/60 Hz • Automatic alarm reset,horn silence switch,and alarm test switch. ALARM ENCLOSURE:6.5 x 4.5 x 3.0 inch • Alarm horn sounds at 85 decibels at 10 feet(3 meters). (16.51 x 11.43 x 7.62 cm),indoor-outdoor, weatherproof,thermoplastic meets Type • Alarm system(when installed on separate circuit)operates even if 3R water-tight standard pump circuit fails. ALARM HORN:85 decibels at 10 feet • Complete package includes standard SJE SignalMaster•control (3 meters),meets Type 3R water-tight switch with 15 feet(4.57 meters)of cable(other lengths available) standard as installed by factory and mounting clamp. ALARM BEACON:UL Listed,Type 4x beacon • UL Listed for indoor or outdoor use. assembly • CSA Certified. TEST/SILENCE SWITCH:certified to IP66 and • Five-year limited warranty. sIGNwrg IP68 standards f SSPf ® AUXILIARY ALARM CONTACTS(OPTIONAL): 11e5424e ® 120 VAC,5 amps max.,50/60 Hz .14- 1C PRE-MOUNTED TERMINAL BLOCK (OPTIONAL):20 amps,120/230 VAC OPTIONS POWER CORD(OPTIONAL):6 foot (1.8 meter)cord with 120 VAC plug When ordered with the alarm,the system is available with: FLOAT SWITCH:SJE SignalMaster•control switch with mounting clamp • alternate float switch models for high or low liquid level warning. Cable:15 feet(4.57 meters),flexible 18 • auxiliary dry normally open contacts for easy attachment of remote gauge,2 conductor(UL)SJOW,water- devices. resistant(CPE) Float:2.74 inch diameter x 4.83 inch • premounted terminal block so enclosure can also be used as a long(7 cm x 12.3 cm),high impact, junction box for splicing pump,pump switch,and pump power.Meets corrosion resistant NEC standard for junction boxes. polypropylene housing for use in sewage and non- • 6 foot(1.8 meter)power cord and liquid-tight connectors. potable water up to 140°F(60°C) `) SJE RHOMBUS. 1-888-DIAL-SJE•1-218-847-1317 California Prop 65 requires the following:thWARNING Cancer and Reproductive Harm-www.P65Warnings.ca.gov 1-218-847-4617 Fax SEE REVERSE SIDE FOR ORDERING INFORMATION. email:customer.service@sjeinc.com SEE PRICE BOOK FOR LIST PRICE. www.sjerhombus.com D.13 TANK ALERT® XT Alarm System Versatile indoor or outdoor liquid level alarm system. ORDERING INFORMATION STANDARD ALARM (120 VAC) Shipping OPTIONS Part# Description Weight CONTROL SWITCH 1009923 TAXT-01H(120 VAC w/15'SJE SignalMaster High Level) 3.00 lbs. OPTIONS The Tank Alert' 1010261 TAXI-01L(120 VAC w/15'SJE SignalMaster Low Level) 3.00 lbs. xT alarm system 1004442 TAXI-01H(120 VAC w/15'SJE Sensor Float'High Level) 3.00 lbs. comes standard 1005140 TAXI-01L(120 VAC w/15'SJE Sensor Float°Low Level) 3.00 lbs. with a 15 foot SJE S1005141 TAXT-01X(120 VAC no float) 1.50 lbs. swtm control switcchh with mounting float STANDARD ALARM I20withBlockermnaclamp. Other ( VAC) Terminal Shipping are switchesare available. Part# Description Weight See control switch TAXT-01HAUXTB(120 VAC w/15'SJE Si nalMaster• section of the catalog. 1012416 High Level Auxiliary Contacts TB) g 3.50 lbs. To determine the 1022241 TAXT-01HTB(120 VAC w/15'SJE SignalMaster°High Level TB) 2.00 lbs. atere ao alarm with an allternate float,add 1005481 TAXT-01HTB(120 VAC w/15'Sensor Float°High Level TB) 3.50 lbs. the price of the part 1005836 TAXT-01LTB(120 VAC w/15'Sensor Float°Low Level TB) 3.50 lbs. number with"no float" 1006836->TAXT--01XTB(120 VAC no float TB) 2.00 lbs. to the price of the float switch. 1009214 TAXT-01HAUXTB(120 VAC w/15' Sensor Float°High Level 3.50 lbs. U ate for Auxiliary Contacts TB) Water Sewage eweNe SIGNALING STANDARD ALARM (120 VAC)with Options Shipping ® �® Part# Description Weight LISSTEND sszs 1005850 TAXT-01HAUX(120 VAC w/15'Sensor Float°High Level B Aux Con) 3.50 lbs. $Sp 1006690 TAXT-01HPC(120 VAC w/15'Sensor Float°High Level Power Cord) 3.50 lbs. H=High Level L=Low Level X=No Float TB=Includes Terminal Block PC=Power Cord AUX=Auxiliary Contacts MASTER CARTON holds 12 boxed units. SEE PRICE BOOK FOR LIST PRICE. SPECIFICATIONS OTHER INFORMATION VOLTAGE:120 VAC, 50/60 Hz Option Description ALARM ENCLOSURE:6.5 x 4.5 x 3 inches(16.51 x 11.43 x 7.62 cm), indoor -outdoor,weatherproof,thermoplastic,meets Type 3R water-tight standard AUX Auxiliary Alarm Contacts ALARM HORN:85 decibels at 10 feet(3 meters), meets Type 3R water-tight (factory installed) standard as installed by factory PC 6 foot power cord with two ALARM BEACON:UL Listed,Type 4X beacon assembly RCC8 1/2 inch liquid-tight TEST/SILENCE SWITCH:certified to IP66 and IP68 standards connectors AUXILIARY ALARM CONTACTS(OPTIONAL):120 VAC,5 amps max., 50/60 HZ PRE-MOUNTED TERMINAL BLOCK(OPTIONAL):20 amps,120/230 VAC POWER CORD:(optional)6 foot(1.8 meters)cord with 120 VAC plug FLOAT SWITCH:SJE SignalMaster"control switch with mounting clamp CABLE:15 feet(4.57 meters),flexible 18 gauge, 2 conductor(UL)SJOW, water-resistant(CPE) FLOAT: 2.74 inch diameter x 4.83 inch long(7 cm x 12.3 cm),high impact, corrosion resistant polypropylene housing for use in sewage and ` non-potable water up to 140°F(60°C) MAXIMUM WATER DEPTH:30 feet(9 meters),13 psi ELECTRICAL:5 amps,125 VAC/250 VAC,50/60 Hz SJE RHOMBUS Call or fax your order! www.sjerhombus.com I-888-DIAL-SJE(I-888-342-5753) • Fax 218-847-4617 customer.service@sjeinc.com Product offering and pricing are subject to change without notice. ll Rights e 7v d. ®2078 SJE,Inc.a All marts Reserved. D.14 Please visit wwwcsjerhom6us.com far the most current information. SJE RHOMBUS is a trademark of SJE,Inc. ,--- � TECHNICAL ki. Control ® Quality Products by NDS SPECIFICATION NompWHITE PVC SWING CHECK VALVE RATED @125 PSI STATIC PRESSURE @ 72°F MOLDED IN THE USA . y': MADE OF PVC TYPE I MATERIAL EPDM FLAPPER ALL PARTS ARE NSF/ANSI 61 +372 LISTED EXCEPT 1520V20 IPS SLIP X IPS SLIP • IPS-IRON PIPE SIZE ..- (SAME AS SCH.40 PIPE) B A PART A B WEIGHT NUMBER (INCHES) (INCHES) (LBS) IPS CONNECTION 1520-05 3.50 1.94 0.15 U2"IPS 1520-07 3.50 1.94 0.20 3/4"IPS 1520-10 5.00 2.34 0.35 1"IPS 1520-12 5.32 3.16 0.55 1 1/4"IPS C 1520-15 5.45 3.16 0.60 1 1/2"IPS 1520-20 6.14 4.23 0.95 2"IPS 1520-30 8.57 5.71 2.50 3"IPS 1520-40 9.60 6.35 3.30 4"IPS I520V20* 6.14 4.23 0.95 2"IPS *CONTAINS VITON FLAPPER °m NG1� ndspro.c ,-- -,SI TECHNICAL ECHNICAL ® Quality Products by NDS SPECIFICATION SCHEDULE 80 PVC UNIONS RATED @150 PSI STATIC PRESSURE @ 72°F MOLDED IN THE USA MADE OF PVC UP TO 4"NSF/ANSI 61+372 LISTED(NOT SM OR TM) \ ! 0 ' UP TO 2"UPC LISTED(NOT SM OR TM) t i IPS X IPS CONNECTION IPS-IRON PIPE SIZE(SAME AS SCH.40 PIPE) PART NUMBER A B WEIGHT IPS C-A,CD,U_QUIC6-,VITONO-RING (INCHES) (INCHES) (LBS) CONNECTION U-0500-S U-0500-SV 192 2.09 0.10 1/2" U-0500-T U-0500-TV U-0750-S U-0750-S2.57 2.37 0.20 3/4" U-0750-T U-0750-T U-1000-5 U-1000-SV 2.63 2.67 0.25 1" rac..iii U-1000-T U-1000-TV A U-1250-S U-1250-SV 3.20 2.87 0.40 I 1/4" U-1250-T U-1250-TV U 1500-5 I U-1500 SV 3.74 3.22 0.60 CI 1/2" U-1500-T U-1500-TV B U-2000-S U-2000-SV 4.08 3.59 0.85 2" U-2000-T U-2000-TV U-2500-S U-2500-SV 5.04 4.II 1.45 21.2" U-2500-T U-2500-TV U-3000-S U-3000-SV 5.85 4.39 2.00 3" U-3000-T U-3000-TV U-4000-S U-4000-SV 7.21 5.23 3.30 4" U-4000-T U-4000-TV PART NUMBER C D WEIGHT HIS (EPDM 0-RINGS) (INCHES) (INCHES) (LBS) CONNECTION SXSM TXTM U-0500-SM U-0500-TM 1.92 3.04 0.15 1/2" Cti U-0750-SM U-0750-TM 2.57 3.48 0.30 3/4" 11-1000-SM U-1000-TM 2.63 3.90 0.40 I" U-1250-SM U-1250-TM 3.20 4.20 0.50 I 1/4" U-1500-SM U-1500-TM 3.74 4.66 0.70 1 1/2" U-2000-SM U-2000-TM 4.08 4.89 1.10 2" D S-SLIP T-FEMALE PIPE THREAD SM-SLIP X MALE PIPE THREAD TM-FEMALE PIPE THREAD X MALE PIPE THREAD ndspro.com 11.41 IDO5 � sit� o ntro 1 TECHNICAL a Quality Products by NDS SPECIFICATION .„.," iiiii-PMIP NON-SERVICEABLE BALL VALVE PVC SCHEDULE 40 SOCKETS RATED @150 PSI @ 72°F STATIC PRESSURE VALVE BODY,BALL,HANDLE&STEM ARE PVC 16.. BUNA OR TEFLON BALL SEAT c r EPDM 0-RING ABS CAP - '- fy IPS-IRON PIPE SIZE (SAME AS SCHEDULE 40 PIPE) FPT-FEMALE PIPE THREAD i 2"AND SMALLER VALVES HAVE TWO-SIDED HANDLE 2.5"AND LARGER HAVE SINGLE LEVER HANDLE C r F"w PENIIIMidillillii PART NUMBER A B C 1) WEIGHT IPS LIP FPT INCHES) (INCHES) (INCHES) (INCHES) (LBS) CONNECTION EI310-05 E1320-05 2.98 1.45 2.47 1.33 0.15 1/2"IPS E1310-07 E1320-07 3.49 1.74 2.89 1.56 0.25 3/4"IPS E1310-10 E1320-10 3.96 2.17 3.58 1.86 0.40 1"IPS E1310-12 E1320-12 4.43 2.69 4.13 2.22 0.70 1 1/4"IPS F131115, E1320-I5 4.80 2.79 4.21 2.22 0.75 11/2"IPS E1310-20 E1320-20 5.40 3.37 4.85 2.66 1.15 2"IPS E1310-25 E1320-25 7.00 4.52 6.51 6.35 3.05 21/2"IPS E1310-30 E1320-30 8.22 5.13 7.22 6.35 3.90 3"IPS E1310-40 E1320-40 11.53 6.50 9.00 8So 8.95 4"IPS E1310-60 N/A 15.88 9.50 12.00 10.15 2I.25 6"IPS e010ndspro.com NII -4. 0 LASCO' Fittings, inc. SUBMITTAL 1- t SCHEDULE 40 PVC 1+.�I1• I�-- `' .r . • - LASCO Fittings, Inc., an Aalberts Industries company, spe- c cializes in the production and sale of injection molded fittings for Irrigation, Plumbing, Industrial, Pool/Spa and Retail mar- -, kets. LASCO Fittings, Inc. operates a 26-acre manufacturing facility in Brownsville,TN.With eight Regional Distribution Fa- cilities strategically located within the United States, LASCO provides worldwide distribution and overnight service. Injection Molded PVC Pipe Fittings in sizes 3/8" through 12" LASCO Fittings, Inc:s comprehensive line of PVC fittings offers a variety of injection molded configurations in Schedule 40 sizes 3/8"through 12"conforming to ASTM O 2466. STANDARDS AND SPECIFICATIONS-Schedule 40 40111111111111 ASTM D-1784-Rigid Poly(Vinyl Chloride)(PVC)Compounds and Chlorinated Poly Vinyl Chloride)(CPVC)Compounds. ASTM D-2466-Socket Type Poly(Vinyl Chloride)(PVC)Plastic Pipe Fittings,Schedule 40. ASTM F-1970- Standard Specification for Special Engineered Fittings,Appurtenances or Valves for use in Poly(Vinyl Chloride) (PVC)or Chlorinated Poly(Vinyl Chloride)(CPVC)Systems. MATERIAL- LASCO Schedule 40 Fittings are produced from PVC Type 1,Cell Classification 12454-B. -0-rings are produced from a Buna-N(NItrile)material. LISTINGS- NSF/ANSI Standard 61,Annex G:Drinking Water System Components Weighted average lead content of 50.25% and is in compliance with California's Health&Safety Code Section 116875(commonly known as AB1953)NSF/ANSI Standard 14:Plastics Piping system Components and Related Materials.Includes/ANSI Standard 61,Annex G DO NOT USE LASCO FITTINGS FOR COMPRESSED AIR OR GASES. DO NOT TEST PVC PIPING SYSTEMS WITH COMPRESSED AIR OR GASES. DO NOT USE FITTRNGSWITH LIQUIDS NOT RECOMMENDED BY LASCO. MODIFICATIONS Of FITTINGS VOIDS THE WARRANTY. MADE IN USA Limited Warranty LASCO Fittings,Inc.products are warranted to be free from manufacturing defects in materials and workmanship.They are warranted against rot,rust,and electrolytic corrosion for a period of three years from date of installation.If LASCO products prove defective due to manufacturing defects in material or workmanship during that period,the manufacturer will provide new replacement units of the same type and size.No remedy will be granted under this warranty if LASCO products are not used strictly in accordance with LASCO's directions with respect to use and storage or if the products have been modified in any way.THE MANUFACTURERS LIABILITY UNDER EXPRESSED OR IMPLIED WARRANTY OR FOR ANY REASON IS LIMITED TO FURNISHING REPLACEMENT UNITS OR GRANTING A CREDIT FOR DEFECTIVE UNITS.NO TABOR EXPENSE OR CONSEQUENTIAL DAMAGES WILL BE PAID BY LASCO.THIS WARRANTY IS IN LIEU OF ALL OTHER GUARANTEES AND WARRANTIES,EXPRESSED OR IMPLIED,INCLUDING BUT HOT LIMITED TO,WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE,EXCEPT FOR ANY WARRANTIES IMPLIED BY LAW FOR NONCOMMERCIAL CONSUMERS.ANY SUCH WARRANTIES ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. 414 Morgan Street•Brownsville,TN 38012 (731)772-31801 www.lascofrttimgs,com Thisspecifcation rTprovidedkrreference only.LASCO Fittings.Inc reserves the right to change nay portion of this sperifitatron without notice dwithoutmarring obligation ro make sa[h changes tolASCO products preriaaslyasabsequendy sold Nose eisA our ewbsite wwwmstohttvrgs.tom for fhemost arrerRinformation. Al ANDUAtBESTRRITS IES HD Fowler Submittal Package • Fought & Company Z Tigard , OR "Storm & Media Filter Exterior Piping" 4 10 Pages a. v' OG ` W ' FOR: BY: 0 McKillip Excavation Inc H.D. Fowler PO Box 585 Chris Moore • Donald, OR 28800 SW Boberg Road • ** Sam McKillip ** Wilsonville, OR 97070 H.D. FOWLER COMPANY BELLEVUE,WA • BELLINGHAM,WA • BOISE,ID • BOZEMAN,MT • BREMERTON,WA EUGENE,OR • HAYDEN,ID • HERMISTON,OR • IDAHO FALLS,ID • JACKSON,WY MARYSVILLE,WA • MEDFORD,OR • OLYMPIA,WA • PACIFIC,WA • PASCO,WA REDMOND,OR • SPOKANE,WA • TWIN FALLS,ID • VANCOUVER,WA WENATCHEE,WA • WILSONVILLE,OR • YAKIMA,WA JMIagIe fowri ad bngers seonmtioarlsr ow- GRAVITY SEWER SUBMITTAL AND DATA SHEET PIPE SIZE AVERAGE 0.D. NOM. I.D. MIN.T. MIN. E APPROX. D APPROX. WEIGHT (IN) (IN) (IN) (IN) (IN) (IN) (LBS/FT) SDR 35 (PS46) ASTM D3034 4 4.215 3.975 0.120 3.50 4.695 1.05 > 6 6.275 5.915 0.180 4.25 6.995 2.36 > 8 8.400 7.920 0.240 4.75 9.360 4.24 10 10.500 9.900 0.300 6.00 11.700 6.64 > 12 12.500 11.780 0.360 6.25 13.940 9.50 15 15.300 14.426 0.437 7.25 17.048 14.19 SDR 26 (PS115)ASTM D3034 4 4.215 3.891 0.162 3.50 4.863 1.40 6 6.275 5.793 0.241 4.25 7.239 3.11 8 8.400 7.754 0.323 4.75 9.692 5.63 10 10.500 9.692 0.404 6.00 12.116 8.84 12 12.500 11.538 0.481 6.25 14.424 12.56 > 15 15.300 14.124 0.588 7.25 17.652 18.90 PS46,ASTM F679 > 18 18.701 17.629 0.499 8.00 20.845 21.43 21 22.047 20.783 0.588 9.50 24.575 29.88 24 24.803 23.381 0.661 9.60 27.647 38.96 27 27.953 26.351 0.745 10.10 31.157 49.47 30 CIOD 32.000 30.194 0.853 16.75 35.612 64.18 36 CIOD 38.300 36.042 1.021 19.02 42.816 93.00 42 CIOD 44.500 41.948 1.187 22.43 49.604 - 48 CIOD 50.800 47.888 1.355 I 24.78 56.624 - PS115,ASTM F679 18 18.701 17.261 0.671 8.00 21.581 28.49 21 22.047 20.349 0.791 9.50 25.443 - 24 24.803 22.891 0.889 9.60 28.627 - 27 27.953 25.799 1.002 10.10 32.261 - 30 CIOD 32.000 29.070 1.148 16.75 36.348 - 36 CIOD 38.300 35.464 1.373 19.02 45.438 - 42 CIOD 44.500 41.072 1.596 22.43 51.356 - 48 CIOD 50.800 46.886 1.822 24.78 58.628 - GPK FITTING SUBMITTAL SHEET Intro: GPK manufactures PVC sewer fittings in accordance with either ASTM D 3034,F 1336 or F 679 to be used in gravity flow or low pressure applications. Injection molded fittings are produced in sizes 4"(100mm)through 12"(300mm)diameter. Fabricated fittings are produced in sizes 4"(100mm)through 36"(973mm)diameter. Material: Fabricated fittings are manufactured from PVC pipe and molded components meeting the requirements of either ASTM D 3034,F 1336 or F 679 for workmanship,extrusion quality, stiffness,impact resistance,dimensions and structural performance. Extruded pipe components are made from PVC material with a minimum cell classification of 12454, 13343 or 12364 as defined in ASTM D1784. Injection molded fittings are made from PVC material with a minimum cell classification of 12454 or 13343 as defined in ASTM D 1784. Extrusion Quality: Extruded components are tested in accordance with and meet the requirements of ASTM D 2152 for properly fused PVC. Impact Resistance: Extruded Components are tested in accordance with ASTM D 2444 using a 20 lb(9.07kg). Tup A and a Flat Plate Holder B. The strength shall equal or exceed the values shown below: 4"—5" 150 Ft-Lbs 6"—8" 210 Ft-Lbs 10"—36" 220 Ft-Lbs (100mm—125mm 2031) (150mm—200mm 284 J) (250mm—973mm 299 J) Impact Resistance: Injection molded fittings are tested In accordance with ASTM D 2444 using a 20 lb(9.07kg). Tup A and a Flat Plate Holder B.The strength shall equal or exceed the values shown below: 4" 50 Ft-Lbs 6"—8" 75 Ft-Lbs 10"—12" 90 Ft-Lbs (100mm 68 J) (150mm—200mm 102 J) (250mm—300mm 122 J) Pipe Stiffness: Extruded Components are tested in accordance with ASTM D 2412. The stiffness equals or exceeds the requirements of ASTM D 3034 and F 679. Pipe Flattening: Extruded components are flattened as described in ASTM D 3034 and F 679 until the distance between the plates is 40%of the outside diameter of the pipe. There shall be no splitting, cracking or breaking. Pressure/Pressure Deflection: Gasketed joints are tested in accordance with ASTM D 3212. Pressure:10 minutes @ 10.8 psi(74.5 kPa)+10 minutes deflected @ 10.8 psi(74.5 kPa). Vacuum: 10 minutes @ 22 in.Hg(74 kPa)+10 minutes deflected @ 22 in.Hg(74kPa). Branch Bending: The chemically fused areas around the fabricated branches of tee,wye and tee-wye fittings are tested to ASTM F 1336 to verify their strength and integrity. Pipe Stop Support: Tee and tee-wye fittings are tested to requirements of ASTM F 1336 for pipe stop load support. No cracking or splitting shall occur and pipe spigot shall not protrude into waterway of the fitting. Joining Methods: Chemically Fused Solvent Weld Joints Solvent cement is handled and tested in accordance with ASTM D 2564 and D 2855. The Lap Shear Strength shall equal or exceed 900 psi(6205 kPa)@ 72 hours. Heat Fusion Welded Joints(Butt Fusion Welds) Elastomeric Seals(Gaskets) Must meet all requirements of ASTM F 477 and D 3212. Saddles: Injection Molded saddle tees and saddle wyes shall have skirts with a minimum of 80 square inches(516 square cm)surface area which can be bonded to pipe. Fabricated saddle tees and saddle wyes shall have skirts with a minimum of 160 square inches (1032 square cm)surface area which can be bonded to pipe. The worm drive saddle straps used to fasten the saddles are manufactured with corrosion resistant 300 series AISI stainless steel. GPK does not recommend gasket skirts where air tests are required. Epoxy Reinforced Welds. 2 811 or li (HpK SDR35 D 3034 / PS46 F 679 FITTING SPECIFICATIONS p IPRODUCTS,M. 1.0 GPK PVC Sewer Fittings shall be manufactured in accordance with either ASTM D 3034,F1336 or F 679. The PVC material shall have a minimum cell classification of 12454,13343 or 12364 as defined in ASTM D 1784. 2.0 The purpose of GPK in-line fittings is to convey municipal sanitary and industrial wastes,storm water runoff and many other related applications. They are designed to be used in gravity flow and low pressure applications not to exceed 10.8 psi.(74.5 kPa). 3.0 Injection Molded Fittings are produced in sizes 4"(100mm)through 12"(300mm)diameter. Fabricated Fittings are produced in sizes 4"(100mm)through 36"(973mm)diameter.A fabricated fitting is considered any fitting made from pipe or a combination of pipe and molded components. 4.0 Chemical Resistance GPK fittings resist attack from certain alcohols,alkalies,salt solutions,acids and other types of chemicals. Refer to chemical resistant chart for suitability. 5.0 Marking.GPK fittings shall be marked with applicable size,"PVC",company name or logo,PSM and the ASTM specification number(D 3034,F 1336 or F679). The fittings and/or packaging shall Include the manufacturer's date and shift code. 6.0 Testing. A test after installation of either low pressure air(Uni-B-6)or a water infiltration-exfiltration test is recommended. 7.0 Deflection Test. The maximum allowable pipe fitting deflection should be 7 Y%of base ID as shown in table X1.1 of D 3034,and X2.1 of F 679. 8.0 Backfilling and Tamping. Backfilling should follow closely after assembly of pipe and fittings. 8.1 Backfilling.with proper material is important to achieve desired density in haunching area which enables pipe,fitting and soil to work together to meet designed load requirements. This eliminates excess deflection and shear breaks due to heavy loads. Approved material shall be used properly,compacted continuously above and around the pipe and fittings as well as between fitting and trench wall. A cushion of approved material up to a minimum of 12"(305mm)over the fittings and between the trench walls shall be applied in accordance with the engineers' specifications. 8.2 Tamping. This shall be done by hand tamping of the embedment material between the trench wall of the service line fitting and riser connection. Tamping can also be done by mechanical tampers or by using water to consolidate the embedment material. Extreme unstable ground conditions may require wider trenches to enable you to compact a larger area around the pipe and fittings to the density consistent of the original ground surface conditions. 9.0 Service Lines. Normally,service lines from the property line to the collection sewer should be a minimum depth of 3 feet(1 meter)at the property line and should be laid in straight alignment and uniform slope of not less than%"per foot(20.8mm/meter)for 4"(100mm)nominal pipe and 1/8"(10.4mm/meter)per foot for 6"(150mm)pipe. Where collection sewers are deeper than 7 feet(2 meters)a vertical standpipe or stack is permitted but not recommended,consult the project engineer for proper installation details. Deep sewer chimney and risers necessitate extreme care during backfilling. Where surface loading is anticipated the final backfill must be compacted to a density compatible with those surface loads to be encountered. 9.1 Backfilling around pipe service laterals on slope. Extra attention should be given on slopes to prevent the newly backfilled trench from becoming a"French Drain". Before backfilling completely there is a tendency for ground and surface water to follow the direction of the looser soil. This flow may wash out soil from under or around pipe and branch line fittings,reducing or eliminating the support needed. To avoid this problem the backfilling should be of greater compaction. Tamping should be done in 4"(100mm)layers and continued in this manner all the way up to the ground or surface line of the trench. Concrete collars or other concrete poured around the fitting to stabilize unwanted movement is recommended to prevent water from undercutting the underside of the pipe and fittings. Summary: Due to various ground conditions and different situations,installation techniques vary widely. We warranty our products to be free of manufacturer's defects. We will not replace the products that are installed or used incorrectly. The design of the systems that our product is used in is a factor that cannot be overlooked. 811 1 Adapting PVC to Concrete Has Never Been More Advanced Durability, Reliability and Versatility NroO A GPK-designed, heavy duty rubber CONCRETE MANHOLE gasketmanhole adapter.is fit into each hol The M gasket joint eliminates many pipeline junction GPKSURESEAL problems, virtually guaranteeing a fitting that is GASKET leak proof. It exceeds 10.8 p.s.i. pressure testing PVC PIPE and withstands a vacuum of 22 in. Hg for zero -7� infiltration of ground water. This design also allows for compression and low insertion pres ,, ; sures during installation. GPK gaskets also maintain enough flexibility to adjust for pipe ?i;� ', y It PVC MANHOLE �• ADAPTER WITH GPK deflection long after the installation process has w- : SILICA-IMPREGNATED been completed. " SURFACE The smooth inner wall of the PVC sleeve ° • provides optimum flow conditions. The exterior " ' ' . GROUT has an abrasive silica layer that allows grout to bond the adapter into the concrete manhole, assuring a solid, watertight seal. GPK Manhole Adapters Tested for tv "Sheer" Strength x ' s a, -` In the Mechanical Engineering Laboratory at North Dakota State University, the GPK PVC Manhole Adapter was tested for "sheer" strength. v /J A variety of bonding materials were used to grout the adapter into the manhole. The - % Tinius-Olsen Force Tester was used to provide ';4.., the test data (see Table 1). Tests recorded an t" '42'.. average force over 3 tons p.s.i. was required to After an opening has been Apply a non-shrinking grout break the bond of the GPK Manhole Adapter. made in the wall of the or concrete mixture in Note that is would be next to impossible to concrete manhole, position between the adapter and duplicate this force in a normal field application. the GPK Adapter in the manhole. center of the opening. GPK PVC Manhole adapters, Installed _k using the proper conventional methods, are c 7, superior to anything else on the market for strength and flexibility. TABLE 1 Force (in pounds) 4.. required to break '^" i adapter out of $j Grout Used Curing Time manhole. j Quikrete 37 Days 10,300 Allow the bonding material Quikrete 4 Days 4,600 to cure properly to assure a Quikrete 4 Days 4,880 watertight seal. NOTE: Table 1 Shows Results of Three Tests Done at an Independent Laboratory Using Quikrete Mortar Mix that is Made to Meet ASTM Designation 387 for Type N Mortar. 51051K'S Diaphragm Valves Flan•ed ix Y a 6 Asahi/America -Type-14 Flanged Diaphragm Valves The Type-14 diaphragm valve features improved body to bonnet sealing performance,visual aposition indication,weir design for excellent throttling capabilities and built in travel stop to prevent over-tightening and eliminate compressive strain.Bubble tight sealing can be achieved even in tough applications containing suspended particles or slurrys. Features: °` Altti •Flanged(ANSI)face-to-face dimensions are equivalent to most metallic valves •Body and bonnet constructed of thermoplastic for maximum corrosion resistance `,4 » •Uniquely designed body and bonnet for superior sealing I •Weir design for excellent throttling i •Bubble-tight sealing,even in applications such as slurries or suspended particles •Bonnet seals to protect internals from corrosive environments s •Built-in travel stop to prevent over-tightening _ PTFE Diaphragm EPDM Diaphragm PTFE Diaphragm da or compressive strain on diaphragm Size Part List Part List Size Part List Part List r •Indicator at the top for indication of valve Number P,rice($ .Number Price($) (in) Number Price($) Number Price($) a ._ r position and prevention of over-tightening PVC Body with PVC Bonnet-Flanged (PVC Bodywith PP Bonnet-Flanged •PVDF gas barrier,which protects EPDM r2 1461005 138.00 1462005 225.00 1/2 1463005 207.00 1464005 295.00 a backing from gas permeation 3/4 1461007 155.00 1462007 234.00 3/4 1463007 225.00 1464007 316.00 1= •Bayonet structure to connect compressor 1 1461010 198.00 1462010 316.00 1 1463010 285.00 1464010 391.00 and diaphragm 11/4 1461012 236.00 1462012 399.00 13/4 1463012 410.00 1464012 489.00 11/2 1461015 299.00 1462015 467.00 1% 1463015 439.00 1464015 582.00 e Options: 2 1461020 354.00 1462020 576.00 2 1463020 525.00 1464020 653.00 0 311 •2"Square Nut 21/2 1461025 508.00 1462025 801.00 21/2 1463025 734.00 1464025 1,090.00 y LL •Chain Operator 3 1461030 579.00 1462030 996.00 3 1463030 940.00 1464030 1,341.00 •Stem Extensions(Single and two-piece) 4 awe846.00 1462040 1,406.00 4 1463040 1,246.00 1464040 1,892.00 •Locking Device(For tamper-proofing) 5 1461050 1,313.00 1462050 2,584.00 PVDF Body with PPG Bonnet-Flanged e 6 1461060 1,795.00 1462060 3,329.00 /2 - - 1468005 267.00 8 1126080 3,841.00 1127080 4,737.00 3/, 1468007 300.00 10 1126100 6,532.00 1127100 9,062.00 1 - - 1468010 443.00 a PP Body with PP Bonnet-Flanged 11/4 - - 1468012 616.00 c o. 1/2 1465005 179.00 1466005 265.00 144 - - 1468015 656.00 .13 m 2/4 1465007 195.00 1466007 277.00 2 - - 1468020 830.00 io 1 1465010 247.00 1466010 373.00 21/2 - - 1468025 1,199.00 1%4 1465012 310.00 1466012 440.00 3 - - 1468030 1,512.00 P 114 1465015 381.00 1466015 551.00 4 - - 1468040 2,157.00 5 i 2 1465020 449.00 1466020 674.00 5 - - 1468050 3,314.00 a, i 21/2 1465025 635.00 1466025 942.00 6 - - 1468060 5,069.00 3 1465030 730.00 1466030 1,167.00 8 - - 1136080 10,289.00 ✓ 4 1465040 1,070.00 1466040 1,640.00 10 1136100 14,724.00 o c7 5 1465050 1,575.00 1466050 2,805.00 B All diaphragm with PTFE diaphragms have PVDF gas barriers .o 6 1465060 2,102.00 1466060 3,633.00 as a standard feature. 8 1132080 4,613.00 1133080 5,500.00 10 1132100 7,842.00 1133100 10,318.00 g as+wVAMERICA 7 276 HARRINGTON Always Available @ 1-800-877-4472 WMP-Series PLASTIC-BODIED MAGMETER Seametrics APPLICATIONS - 3 inch Industrial wastewater discharge Grey water Well monitoring \ " Irrigation Pr Mining 2 inch 1 inch Features The WMP-Series is a full-bore,plastic-bodied electromagnetic flow meter No movingparts designed for flow and usage monitoring applications in 1, 2 and 3 inch • pipe. The polypropylene flow tube offers corrosion resistance to a wide • Minimal straight pipe required range of chemicals and fertilizers. It is light weight and easy to install or remove from the pipe for inspection. • Battery powered With no moving parts, the magmeter permits unobstructed flow, Built-in rate & total indicator minimizing flow disturbances and straight pipe requirements. The WMP- • Series can be used in piping configurations where there is little space • Corrosion resistant between the meter and an elbow or valve. The WMP-Series is resistant to wear from sand and debris found in ground or surface water. Since • Pulse output (WMP101 only) there are no bearings or propeller to wear out, maintenance and repair costs are kept to a minimum and it tolerates high flows without damage. A hinged polyethylene cover is included that protects from dust and UV rays,while permitting easy access to the flow rate and total display.The electronics housing can be fitted with cross-drilled screws and seal wire for tamper-evidence. Flow rate and total can be displayed in a variety of units,customer-selected and factory-set. Ir The WMP101 is externally powered via a 5-pin connector cable(20ft/6m) Unobstructed Flow which also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to- analog conversion,and telemetry applications. The WMP104 is a battery-operated unit for use when pulse output is not required.The standard batteries are user replaceable with an approximate Contact Your Supplier 1 year life depending on usage.An extended battery life option offers an estimated 2-4 year life depending on usage. In the event of DC power loss, or when changing batteries,the WMP will retain internal settings and flow total. USA.: 9001 253.872.0284 seametrics.com WMP-Series Seametr�cs PLASTIC-BODIED MAGMETER Features Polyethylene protective cover ► 11110C) LCD rate and total indicator Powder-coated diecast aluminum electronics housing —� dirdit)j Cross-drilled screws(2)for tamper-evidence ""5 Seametrics Fitting Kit for 2&3 inch model 316SS electrodes Corrosion-resistant glass-filled polypropylene body --� Lightweight for easy handling Specifications* Pipe Size 1,2,or 3 inch full port Fittings 1 inch NPTF,2 or 3 Inch flange clamps with 2 or 3 inch NPTF fitting kit Pressure 150 psi or 10.3 bar working pressure @ 70'F Operating Temperature Range Operating:10'to 130"F(-12°to 54°C),Non-operating:-40'to 176°F(-40'to 80°C) Accuracy ±1%of reading(between 10%and 100%of maximum flow) t3%of reading(between cutoff and 10%of maximum flow) Flow Range Minimum 1":2.3 gpm(0.145 Vs) 2":6 gpm(0.38Ifs) 3":14 gpm(0,88 Vs) Maximum 1":110 gpm(6.94 Vs) 2":300 gpm(18.9 Vs) 3":670 gpm(42.3 Vs) Materials Body GlasS-filled polypropylene Electrodes 316 stainless steel Electronics Housing Power coated diecast aluminum Display Cover Polyethylene Display Rate Total Digits 6 8 Units Gallons/Minute,Million Gallons/Day, Acre-Feet,Acre-Inch,Gallons,Gallons x 1000, Cubic Feet/Second, Cubic Feet,Liters,Megaliters,Cubic Meters, Cubic Feet/Minute,Liters/Second,Liters/Minute, Cubic Meters x 1000 Million Liters/Day,Cubic Meters/Minute, Cubic Meters/Hour Security Cross-drilled screws and tamper-evident seal(optional) Power WMP101 10-30 Vdc @ 60 mA maximum(15 mA average) Note:Using an unregulated power supply>18 Vdc may damage the meter due to AC line input voltage fluctuation. W MP104 6-AA 1.5V lithium cells,replaceable.Estimated life is 1 year depending on usage(standard) 2-C 3.6V lithium batteries,replaceable.Estimated life is 2-4 years depending on usage(extended battery life opt) Pulse Output Signal(WMP101 only) Current sinking pulse,opto-isolated,32 Vdc maximum @ 10mA maximum Pulse Rate Low Frequency(-NU) 1 unit/pulse out,pulse width of 10 ms,depending on unit selection (WMP101 only) High Frequency(-HF) 1" 2" 3" Pulse width 1.1 ms,min-max frequency,3-150 Hz Pulse/Gal 80 30 13 Pulse/Liter 21.14 7.93 3.44 Empty Pipe Detection Hardware/software,conductivity based Conductivity >20 microSiemens/cm Environmental NEMA 3X,IP64 Electrical Connection(WMP101 only) 5-pin male circular connector,mates to industry standard cable *specifications subject to change•Please consult our website for current data(seametrics.com). 253.872.0284 Page 2 seametrics.com WMP-Series Seamettics PLASTIC-BODIED MAGMETER How to Order MODEL SIZE OPTIONS UNITS External Power=WMP101 1"=-100 Tamper-evident seal, Rite Total screws,and wire=-32 Gal/Min =GPM Gal = G Battery Power=WMP104 2"=-200 Extended Battery Life=-133 Liters/Sec =LPS Gal x 1000 = GT 3" _ -300 (WMP104 Only) Liter/Min =LPM Cubic Feet = CF *High frequency output=-HF Cu Ft/Sec =CFS Acre Inch = Al (WMP101 Only) BSP fittings= -93 Cu Ft/Min =CFM Acre Feet = AF Cu Met/Min=CMM Liter = L Cu Met/Hr =CMH Mega Liters = ML Mil Gal/Day =MGD Cubic Meters = CM Mil Lit/Day =MLD Cu Met x 1000 = CMT `See specifications for default Consult factory for additional units. ACCESSORIES Remote Rate and Total Indicator(DC powered)=FT430W(-HF Option Required,WMP101 Only) Remote Rate and Total Indicator(Loop powered)=FT440W(-HF Option Required,WMP101 Only) Remote Data Logger=DL76W(WMP101 Only) 2"Fitting Kit,FNPT Flange Clamps=101222 2"Fitting Kit,BSP Flange Clamps =102203 3"Fitting Kit,FNPT Flange Clamps=102073 3"Fitting Kit,BSP Flange Clamps =102204 Seametrics• 19026 72nd Avenue South • Kent,Washington 98032-USA 1-6565029Or2120200114 (P)253.872.0284•(F)253.872.0285 • 1.800.975.8153•seametrics.com 1/14/2020 SPEARS PVC SCHEDULE 80 FITFINGSAIIMPFIL) 80-2.0716 Performance Engineered & Tested SPEARS®Schedule 80 PVC product designs combine years of proven experience with computer generated stress analysis to yield the optimum physical structure and performance for each fitting.Material reinforcement is uniformly placed in stress concentration areas for substantially improved �4 � pressure handling capability. Resulting products are subjected to numerous verification tests to assure obtaining the very best PVC fittings available. 1114,' 1/4"Through 14"Availability Higher Flow Capacity Spears®comprehensive line of PVC injection molded fittings Smooth interior walls result in lower pressure loss and and extruded pipe offers a variety of configurations in sizes higher volume than conventional metal fittings. 1/4" through 14". Schedule 80 fittings are manufactured to Additional Fabricated ASTM D 2467 and pipe is produced to ASTM D 1785. Spears® exclusive CL 150 Flanges are produced in sizes 1/2"-18"with Configurations through 36" ANSI B16.5 bolt patterns, plus numerous Unions, Saddles, Extra large, hard-to-find, and custom configurations Transition and Specialty fittings in a variety of sizes. are fabricated from NSF® Certified pipe. Fittings are engineered and tested to provide toll pressure handling Exceptional Chemical&Corrosion Resistance capabilities according to Spears®specifications. Unlike metal,PVC fittings and pipe never rust, scale, or pit, Advanced Design Specialty Fittings and will provide many years of maintenance-free service and extended system life. Spears® wide range of innovative, improved products include numerous metal-to-plastic transition fittings and High Temperature Ratings unions with Spears® patented special reinforced (SR) PVC thermoplastic can handle fluids at service temperatures plastic threads. up to 140° F (60° C), allowing a wide range of process PVC Valves applications,including corrosive fluids. SPEARS® PVC Valve products are available for total Lower Installation Costs system compatibility and uniformity; see VALVES IN Substantially lower material costs than steel alloys or lined SPEARS®PRODUCT SOURCE BOOK. steel,combined with lighter weight and ease of installation,can reduce installation costs by as much as 60%over conventional metal systems. Sample Engineering Specifications All PVC Schedule 80 pipe and fittings shall be produced by Spears° Manufactunng Company from PVC Type I, cell dassification 12454, conforming to ASTM Standard D 1784.All PVC injection molded Schedule oN c¢eriF, 80 fittings and extruded pipe shall be Certified for potable water service by NSF®International. All Schedule 80 fittings shall be manufactured in strict compliance to ASTM D 2467 and Schedule 80 pipe shall be , � d LPCB U K A S manufactured in strict compliance to ASTM D 1785.All fabricated fittings i MINIMshall be produced in accordance with Spears°General Specifications for ° Fabricated Fittings.All PVC flanges shall be designed and manufactured Wr to meet CL150 bolt pattern per ANSI Standard B16.5 and rated for a Assessed to ISO 9001:20ee maximum internal pressure of 150 psi,non-shock at 73°F through size Certificate"umber 299 18". PROGRESSIVE PRODUCTS FROM SPEARS'INNOVATION g TECHNOLOGY Visit our web site: www.spearsmfg.com PVC Thermoplastic Pipe Temperature Pressure De-Rating To determine the maximum internal pressure rating at an elevated temperature,simply multiply the pipe pressure rating at 73°F by the percentage specified for the desired temperature. System Operating 73 80 90 100 110 120 130 140 Temperature*F(°C) (23) (27) (32) (38) (43) (49) (54) (60) PVC 100% 90% 75% 62% 50% 40% 30% 22% NOTE:Valves,Unions and Specialty Products have different elevated temperature ratings than pipe. INNMP Typical Material Properties ASTM PVC Chemical Resistance Properties Test PVC PVC is generally inert to most mineral acids, bases, Method salts and paraffinic hydrocarbon solutions. For more Mechanical Properties,73°F information on PVC chemical resistance refer to the Chemical Resistance of Rigid Vinyls Based on Immersion Specific Gravity,g/cma D 792 1.41 Test,published by the GEON®company. Tensile Strength,psi D 638 7,200 Modulus of Elasticity,psi 0 638 440,000 Compressive Strength,psi D 695 9,000 Flexural Strength,psi D 790 13,200 Izod Impact,notched,ft-lb/in D 256 .65 Thermal Properties Heat Deflection Temperature,°F at 68 psi D 648 165 Thermal Conductivity,BTU I hr/sq ft I°F/in C 177 1.2 NOT FOR DISTRIBUTION OF Coefficient of Linear Expansion,in/in/°F D 696 3.1 x 10'5 COMPRESSED AIR OR GAS Flammability Limited Oxygen Index,% D 2863 43 UL 94 Rating 94V-0 Other Properties Water Absorption,%24 hr. D 570 .05 ND ti{ 41 Industry Standard Color White/Dark Gray =e ASTM Cell Classification D 1784 12454 NSFe Potable Water Approved YES ir SPEARS®MANUFACTURING COMPANY•CORPORATE OFFICE 15853 Olden St.,Sylmar,CA 91342•PO Box 9203,Sylmar,CA 91392 SPEARS = : (818)3641611•www.spearsmfg.com lbw SPEARS SPEARS°DISTRIBUTION CENTERS September 04,2016 PACIFIC SOUTHWEST SOUTH CENTRAL UTAH FLORIDA NORTHEAST 15860 Olden SL 1000 Lakeside Parkway 5395 West 1520 South 9563 Parksouth Ct. 590 Industrial Dr.,Suite 100 Sylmar(Los Angeles),CA 91342 Flower Mound,TX 75028 Salt Lake City,UT 84104 Orlando,FL 32837 Lewisberry(Harrisburg),PA (818)364-1611.(800)862-1499 (469)5283000•(800)441-1437 (303)371-9430•(800)7774154 (407)843-1960•(800)327-6390 17339-9532 Fax(818)367-3014 Fax(469)5283001 Fax(303)375 9546 Fax(407)4253563 (717)938-8844•(800)233-0275 Spears' Spears' Fax(717)938-6547 555 Zephyr St 7330 Langrreld Rd. SpeerelAssociated Marketing Stockton,CA 95206 Bldg 300 Suite 100 MIDWEST SOUTHEAST 11500 Roosevelt Blvd. (818)364-1611•(800)862-1499 Houston,TX 77092 1 Gateway CL,Suite 4205ewpuM N PI Suite 100 Building 0,Unit 1 Fax(818)3673614 (469)5283000•(800)441-1437 Bolingbrook(Chicago),IL 60440 Philadelphia,PA 19116 Fax(489)528-3001 (630)759-7529•(800)662.633U Lawanceviile(Manial.GA 30043 (717)9388844•(800)233-0275 Fax(630)759-7515 (678)9651263•(800)662fi326 Fax(717)938-6547 Fax(6713)9855642 NORTHWEST ROCKY MOUNTAIN Spears° Spears' spears• 4103'C'St.NE Suite 200 7001 Soetnede DrCabot Business Park 7 Aubum ISeattlel,WA 98002 4880 Florence 81. Louisville,KY 40214 4835 Sirara Dr.,Suite 400 11 Noddk St. (253)939-4433•(800)347-7327 Denver,CO 8°238 Call your nearest Spears' Charlotte,NC 28273 Mansfie Fax(253)939.7557 (303)371-9430.(800)7774184 Distribution Center (678) -1263•(800)662-0326 (117)0ld,MA02048 Fax(303)375s9596 Fax(676)9855642 717) 38-6844•(800)233-0275 INTERNATIONAL SALES Fax(717)938E547 \ 15853 Olden St.•Sylmar(Los Angeles).CA 91342•(818)364-1611•Fax(818)8983774 111, ©Copyright 2016 Spears°Manufacturing Company. All Rights Reserved.Printed in the United States of America 07/16. 80-2-0716 HD Fowler Submittal Package • Fought & Company Z Tigard , OR "CMP Slotted Drain" ›• 2 Pages a 0 t� W J FOR: BY: 0 McKillip Excavation Inc H.D. Fowler UN PO Box 585 Chris Moore • C Donald, OR 28800 SW Boberg Road • ** Sam McKillip ** Wilsonville, OR 97070 H.D. FOWLER COMPANY BELLEVUE,WA • BELLINGHAM,WA • BOISE,ID • BOZEMAN,MT • BREMERTON,WA EUGENE,OR • HAYDEN,ID • HERMISTON,OR • IDAHO FALLS,ID • JACKSON,WY MARYSVILLE,WA • MEDFORD,OR • OLYMPIA,WA • PACIFIC,WA • PASCO,WA REDMOND,OR • SPOKANE,WA • TWIN FALLS,ID • VANCOUVER,WA WENATCHEE,WA • WILSONVILLE,OR • YAKIMA,WA C=:: NTECHS ENGINEERED SOLUTIONS SPECIFICATION FOR CORRUGATED METAL PIPE SLOTTED DRAINTM - STANDARD HEIGHT GRATE (2 '/z" - 6") - ALUMINIZED STEEL TYPE 2 1.0 GENERAL 1.1 This specification covers the manufacture and installation of Aluminized Type 2 corrugated steel pipe(CSP)with Slotted Drain used for the removal of surface water as detailed in the project plans. 2.0 DESIGN STANDARDS 2.1 The CSP meets the design parameters of the American Association of State Highway and Transportation Officials (AASHTO)Standard Specification for Highway Bridges,AASHTO LRFD Bridge Design, and/or the American Iron and Steel Institute(AISI). 3.0 MATERIAL 3.1 The Aluminized Steel Type 2 coils shall conform to the applicable requirements of AASHTO M 274 or ASTM A929. 3.2 The grate shall be galvanized in accordance with ASTM A123, except with a 2 oz. galvanized coating,total both sides. 4.0 PIPE 4.1 The CSP shall be manufactured in accordance with the applicable requirements of AASHTO M 36 or ASTM A760. The pipe sizes, diameters, gauges, corrugations shall be as shown on the project plans. 4.2 All fabrication of the product shall occur within the United States. 5.0 GRATES 5.1 The grates shall be manufactured from ASTM A1011, Grade 36 steel. The spacers and bearing bars(sides) shall be 3/16" material±0.008". 5.2 The spacers shall be on 6"centers and welded on both sides to each bearing bar(sides)with four(4) 1-1/4" long 3/16" fillet welds on each side of the bearing bar. 5.3 The engineer may call for tensile strength tests on the grate if the grate is not in compliance with Section 5.2. If tensile strength tests are called for, minimum results for an in-place spacer pulled perpendicular to the bearing bar shall be: T= 12,000 pounds for 2-1/2"grate T= 15,000 pounds for 6"grate 5.4 The grates shall have a 1-3/4"opening in the top and be 2-1/2"or 6"high as shown on the plans. Options include: 5.4.1 Vertical (straight sides)grate with a 1-3/4"opening in the top and vertical spacers unless shown otherwise on the plans. The grate shall be 2-1/2"or 6"high as shown on the plans. 5.4.2 Trapezoidal grate with a 1-3/4"opening in the top and 30°slanted spacers unless shown otherwise on the plans. The grate shall be 2-1/2"or 6"high as shown on the plans. 5.5 The grate shall be fillet welded with a minimum weld 1"long to the CSP on each side of the grate at every other corrugation. 6.0 COUPLING BANDS 6.1 Modified HUGGER(7-5/8"wide) bands for the CSP shall be made of the same base metal and coatings as the CSP to a minimum of 18 gauge. 6.2 When the Slotted Drain is banded together,the adjacent grates shall have a typical gap of 2"-3". 6.3 Ends of the CSP are rerolled with annular corrugations for proper indexing. 6.4 Connection fasteners will be provided. 7.0 TOLERANCES FOR FINISHED SLOTTED DRAIN OF 20' LENGTHS 7.1 Vertical Bow:±3/8"; Horizontal Bow: ±5/8"; Twist: ± 1/2" 8.0 HANDLING,ASSEMBLY,&INSTALLATION 8.1 Refer to the recommendations of the National Corrugated Steel Pipe Association's (NCSPA). 8.2 The installation shall be in conformance with the project plans and specifications or the manufacturer's recommendations. If there are any inconsistencies or conflicts,the contractor must bring them to the attention of the project engineer. 8.3 It is always the contractor's responsibility to follow OSHA guidelines for safe practices. 9.0 CONSTRUCTION LOADS 9.1 Construction loads may be greater than design loads. The contractor shall follow the of the manufacturer's guidelines. 11/10/2016 . A MEI N J � 1111.111 HEL-C❑R PIPE (12" THRU 36" DIA.) SIDE VIEW 6" STANDARD STRAIGHT SIDED GRATE EXTENSI❑N , ler° VARIES d • 2-1/2° OR 6' STANDARD STRAIGHT SIDED GRATE N Q 8 HEL-COR PIPE (12" THRU 36" DIA.) gpP O z z NOTES 1) FINISHED ELEVATION IS SET FROM TOP OF GRATE, NOT FROM INVERT OF PIPE. 2) DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES. 3) REFERENCE CONTECH BAND MANUAL DWG.# 1008466 FOR BAND DETAILS. 4) REFERENCE CONTECH SLOTTED DRAIN DWG.# 103381 SECTI❑N A-A 5) FOR GENERAL REQUIREMENTS, BACKFILL TO THE TOP OF PIPE WITH 1500 PSI GROUT, FOR AIRPORT & HEAVY WHEEL LOADS, 3000 PSI CONCRETE IS REQUIRED. 6) ORDER MUST NOTE IF FOR AIRPORT LOADING FOR SPECIAL WELDING & REINFORCEMENT. REF. DWG. 1008136, SD 8 INSTALLATION, AIRPORT LOADINGS. 7) ADDITIONAL GRATES MAY BE STACKED FOR INCREASED HEIGHT. a _ SLOTTED DRAIN arm Iry STRAIGHT SLOT GRATE EXTENSION CONSTRUCTION PRODUCTS INC. DRAWN BY: F.B. REV. BY: CMD SCALE: N/A COPYRIGHT DATE: 5_7_g3 DATE: 6-10-04 1008988C HD Fowler Submittal Package • Fought & Company C) Z Tigard , OR "Force Main & Pump �• Station Connections a4 Pages 0 0 OC W J FOR: BY: 0 McKillip Excavation Inc H.D. Fowler LL PO Box 585 Chris Moore ■ Donald, OR 28800 SW Boberg Road • ** Sam McKillip ** Wilsonville, OR 97070 H.D. FOWLER COMPANY BELLEVUE,WA • BELLINGHAM,WA • BOISE,ID • BOZEMAN,MT • BREMERTON,WA EUGENE,OR • HAYDEN,ID • HERMISTON,OR • IDAHO FALLS,ID • JACKSON,WY MARYSVILLE,WA • MEDFORD,OR • OLYMPIA,WA • PACIFIC,WA • PASCO,WA REDMOND,OR • SPOKANE,WA • TWIN FALLS,ID • VANCOUVER,WA WENATCHEE,WA • WILSONVILLE,OR • YAKIMA,WA vesf or m'144 Building essen[ials �,�5�, Y `,• JMMMMMagle for a better tomorrow- Q w • °nARRgN 7. Z A/ StM�a�/�y0 POLYETHYLENE %G14. p�p� �y WATER & SEWER q"TEE° SUBMITTAL AND DATA SHEET HDPE IRON PIPE SIZE (I.P.S.) PRESSURE PIPE ANSI/NSF-61, 14 LISTED an PE 4710 DR 7 (333 psi) DR 9(250 psi) DR 11 (200 psi) w m Q PIPE AVG. MIN. AVG. WEIGHT MIN. AVG. WEIGHT MIN. AVG. WEIGHT cz SIZE O.D. T. I.D. LB/FT T. I.D. LB/FT T. I.D. LB/FT N 0 1/2 0.840 0.120 0.586 0.12 0.093 0.643 0.10 0.076 0.679 0.08 w 3/4 1.050 0.150 0.732 0.19 0.117 0.802 0.15 0.095 0.849 0.12 H co 1 1.315 0.188 0.916 0.29 0.146 1.005 0.23 0.120 1.061 0.20 o' 1-1/4 1.660 0.237 1.158 0.46 0.184 1.270 0.37 0.151 1.340 0.31 1-1/2 1.900 0.271 1.325 0.61 0.211 1.453 0.49 0.173 1.533 0.41 6 D 2 2.375 0.339 1.656 0.95 0.264 1.815 0.77 0.216 1.917 0.64 2, 3 3.500 0.500 2.440 2.06 0.389 2.675 1.66 0.318 2.826 1.39 4 4.500 0.643 3.137 3.40 0.500 3.440 2.75 0.409 3.633 2.30 w `m 5-3/8 5.375 0.768 3.747 4.85 0.597 4.109 3.92 0.489 4.338 3.29 m 5 5.563 0.795 3.878 5.20 0.618 4.253 4.20 0.506 4.490 3.52 c -o 6 6.625 0.946 4.619 7.36 0.736 5.065 5.96 0.602 5.349 4.99 m 7 7.125 0.976 5.056 8.52 0.792 5.446 6.89 0.648 5.751 5.78 0 8 8.625 1.232 6.013 12.48 0.958 6.594 10.09 0.784 6.963 8.46 ii,- w 10 10.750 1.536 7.494 19.40 1.194 8.219 15.68 0.977 8.679 13.14 w 12 12.750 1.821 8.889 27.28 1.417 9.746 22.07 1.159 10.293 18.49 0 14 14.000 2.000 9.760 32.90 1.556 10.107 26.61 1.273 11.301 22.30 0 w 16 16.000 2.286 11.154 42.97 1.778 12.231 34.75 1.455 12.915 29.12 a 5- 18 18.000 2.571 12.549 54.37 2.000 13.760 43.97 1.636 14.532 36.84 m m 20 20.000 2.857 13.943 67.13 2.222 15.289 54.28 1.818 16.146 45.49 y 22 22.000 3.143 15.337 81.23 2.444 16.819 65.68 2.000 17.76 55.05 m 24 24.000 3.429 16.732 96.67 2.667 18.346 78.18 2.182 19.374 65.52 w c 26 26.000 - - - 2.889 19.875 91.75 2.364 20.988 76.90 m 28 28.000 - - - 3.111 21.405 106.40 2.545 22.605 89.15 30 30.000 - - - 3.333 22.934 122.13 2.727 24.219 102.35 32 32.000 - - - - - - 2.909 25.833 116.46 34 34.000 - - - - - - 3.091 27.447 131.48 36 36.000 - - - - - - 3.273 29.061 147.41 I.D. : Inside Diameter O.D. : Outside Diameter T. Wall Thickness * For data, sizes, or classes not reflected in these charts, please contact JM Eagle-for assistance. TEGRITY sion Products, Inc. 270 Parkade Court, Peachtree City, GA 30269-(P) 1.888.770.6330-www.integrityfusion.com PRODUCT SPECIFICATIONS SHEET MOLDED HDPE FITTINGS PE3408 / PE4710 /PE100 HDPE BLACK • • MATERIAL: IntegriFuse fittings are manufactured with pre-blended black high density bimodal polyethylene copolymer resin recognized by the Plastic Pipe Institute as having a PE3408 I PE4710/PE100 rating and a Hydrostatic Design Basis of 1600 psi @ 73°F.This resin has a cell classification of 445574C in accordance with ASTM D3350. IntegriFuse fittings are designed for use in,but not limited to,potable water,natural gas,industrial, landfill,oil&gas, mining,&irrigation applications. REQUIREMENTS: ASTM D2513 -Specification for Thermoplastic Gas Pressure Pipe,Tubing,and Fittings ASTM D3350 -Specification for Polyethylene Plastic Pipes and Fittings Materials ASTM D3261 -Specification for Butt Heat Fusion Polyethylene(PE)Plastic Fittings for Polyethylene(PE)Plastics Pipe and Tubing ASTM F2880 -Specification for Lap-Joint type Flange Adapters for use on Polyethylene Pressure Pipe ASTM F714 -Specification for HDPE Pipe Dimensions ASTM F1055 -Specification for Electrofusion Fittings REFERENCE DOCUMENTS: PPI TR-19 -Thermoplastics Piping for the Transport of Chemicals PPI TR-31 -Underground Installation of Polyolefin Pipe PPI TR-33 -Generic Butt Fusion Procedure for Polyethylene Gas Pipe PPI TR-4 -Standard Practice for Hydrostatic Design Basis for Polyethylene Pipe ASTM D2657 -Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings CERTIFICATIONS/LISTINGS: FM 1613 -Approval Standard: Plastic Pipe and Fittings for Underground Fire Protection Service AWWA C901/C906 -Standard for Polyethylene Pressure Pipe and Fittings for Water Distribution ANSI/NSF 61&372 -Plastic Piping System Components&Related Materials-NSF/ANSI/CAN 61 &NSF/ANSI 372 TEST METHODS: Time-to-Failure of Plastic Pipe Under Constant Internal Pressure. ASTM D1598 Must exceed 170 hours in 80°C bath @ 670psi Hoop Stress,or Must exceed 1000 hours in 80°C bath @ 580psi Hoop Stress,or Must exceed 1000 hours in 23°C bath @ 1600psi Hoop Stress. (All methods are considered equivalent) ASTM D1599 Short-Term Hydraulic Pressure Failure of Plastics Pipe,Tubing,and Fittings. Uniform pressurization until failure between 60 and 70 seconds from start of test. Most result in ductile failure at a pressure great enough to create a 2520psi Hoop Stress. ASTM D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings Determination of diameter,wall thickness,and length dimensions including procedures for dimensioning molded thermoplastic pipe fittings. IntegriFuse' • • TEGRITY • sion Products, Inc. 270 Parkade Court,Peachtree City,GA 30269-(P)1.888.632.6330-www.integrityfusion.com FEATURES: Manufactured from pre-blended virgin materials. These fittings are availabe in various configurations and DR and are primarily intended for use in pressure piping applications. These fittings are compatible for heat fusion to any PE material made from PE3408/PE4710/ PE100 resins that comply with ASTM D3350.Select sizes can be supplied with AWWA or FM marking. Designed for use on pipe conforming to ASTM F714, D2513, and D3035. PRESSURE RATING: PE4710/PE100 Butt Fusion Fittings are pressure rated in accordance with industry and regulatory guidelines for natural gas or water @73°F. Pressure ratings are subject to change depending on ambient temperatures. Pressure ratings vary according to wall thickness and the design factor for the intended application,see below for ratings: Fitting Pressure Rating(PSI)@ 73°F(23°C) SDR Water(.63 DSF) Water(.5 DSF) Natural Gas(.32 DSF)US Natural Gas(.4 DSF)Canada 7 335 265 170* 215* 9 250 200 125° 160* 11 200 160 100 125 13.5 160 125 80 100 17 125 100 65 80 21 100 80 50 65 26 80 65 40 50 32.5 65 50 30 40 Subject to maximum operating pressure limits of regulatory requirements. Minimum wall thickness for plastic piping gas distribution systems is limited to.062". Above listed pressure ratings based on 73°F ambient temperature. Pressure ratings subject to derating depending on temperature. PRESSURE TESTING: Pressure testing can be conducted in accordance with the recommendations of the pipe manufacturer,or as described in ASTM F2164 STANDARD PRACTICE FOR FIELD LEAK TESTING OF POLYETHYLENE(PE)PRESSURE PIPING SYSTEMS USING HYDROSTATIC PRESSURE, typically 1.5 x's the rated working pressure not exceeding 8 hours in duration for a single test. MAXIMUM OPERATING TEMPERATURE: The maximium operating temperature of PE4710 Butt Fusion Fittings is 140°F. Pressure de-rating factors should be considered when operating systems above the 73°F stated pressure rating,to maintain the 50 year substantiated long-term hydrostatic strength of the polyethylene material. STORAGE/SHELF LIFE: Black high density polyethylene resin contains a minimum of 2%of a finely dispersed concentration of carbon black which provides protection from UV effects. Even so, it is recommended that fittings which are stored for extended periods(two years or greater)be stored indoors in their original packaging. Fittings stored indoors in their original packaging have a virtually unlimited shelf-life. CHEMICAL RESISTANCE: Polyethylene generally exhibits strong resistance to many chemical compounds. Known chemical resistance characteristics at specified temperatures can be found in PPI Technical Report TR-19. INSTALLATION: These fittings are compatible for heat fusion by butt,socket,or electrofusion joining products. They can be heat fusion joined to pipe or fittings manufactured from PE3408/PE4710/PE100 resins that comply to ASTM D3350. Qualified mechanical joining products can be used to join these fittings, consult the manufacturer for recommendations. Fusion jointing should only be attempted by persons who have been trained and have qualified joints through destructive testing. Rev:09/24/19-This document replaces all previous Product Specifications and is subject to change without notice. IntegriFuse' .mR,F--F r ER +GF+ FIH, �x t to GEORG FtSCHER.CEN `RAL LASTICS 39605 Independence,Shawnee,OK,74804 11.800.654.3872 I www.gfcp.com PRODUCT SPECIFICATIONS SHEET MOLDED ELECTROFUSION COUPLINGS .5" CTS - 1.25" CTS .5" IPS - 12" IPS 4" DIPS - 12" DIPS* 'Available in PE 3408 only At Georg Fischer Central Plastics (GFCP)we are proud to be recognized as the company that pioneered and introduced to industries within the United States to the concept of joining polyethylene piping systems together via the process of electrofusion.As an International leader in the world of manufactured Polyethylene (PE) Electrofusion fittings and with manufacturing facilities located around the world, GFCP has been actively involved since the early 1960's in the research and promotion of innovative joining methods for polyethylene piping systems for the natural gas, potable water, wastewater, oilfield, mining landfill,telecommunications and geothermal industries. With unparalleled expertise focusing on the design and manufacturing of polyethylene electrofusion fittings, GFCP offers the largest, most complete line of electrofusion products, manufactured from a variety of common virgin resins, available in the market. Our substantial vertically integrated manufacturing capabilities allow GFCP to exercise complete control of our manufactured products. From design, to "state of the art" manufacturing, to shipping; GFCP maintains a high level of product consistency and quality throughout our manufacturing processes. GFCP Electrofusion Couplings are designed and manufactured in accordance with ASTM F-1055 for use with pipe conforming to ASTM D2513/3035, F-714 and with Butt fittings conforming to ASTM D3261 as applicable . These fittings can be supplied with an integral identification resistor which is recognized by all GFCP's processors to automatically set the proper fusion parameters. Electrofusion fittings are supplied with a 24 digit ISO compliant barcode label which facilitates the fusion of the GFCP electrofusion fitting with other manufacturer's processors. PE2406 Electrofusion Couplings are produced from a pre-blended virgin resin that has a PPI listing of PE2406 which complies with ASTM D3350. PE3408 Electrofusion Couplings are produced from a pre-blended virgin resin that has a PPI listing of PE3408 which complies with ASTM D3350. This resin carries a NSF Standard 61 listing for use with potable water. Available Features: • PE2406 fittings are engineered for use on MDPE Pipe • PE3408 fittings are engineered for use on HDPE Pipe • Compatible for fusion to either PE2406 or PE3408 pipe materials without special fusion procedures. • Pressure rated for natural gas and potable water*applications(*only in some sizes) • PE3408 fittings utilize NSF listed Resin • PE3408 fittings are tested to the requirements of AWWA C906 • PE3408 fittings are FM Approved (4"-24") • CSA Certification • Available in metric sizes Product Specifications Sheet R PO1/2013 HD Fowler Submittal Package Fought & Company Z Tigard , OR "Tank Cross Over" 10 Pages a 0 v C W J FOR: BY: 0 McKillip Excavation Inc H.D. Fowler LL PO Box 585 Chris Moore • Donald, OR 28800 SW Boberg Road • ** Sam McKillip ** Wilsonville, OR 97070 01 H.D. FOWLER COMPANY BELLEVUE,WA • BELLINGHAM,WA • BOISE,ID • BOZEMAN, MT • BREMERTON,WA EUGENE,OR • HAYDEN,ID • HERMISTON,OR • IDAHO FALLS,ID • JACKSON,WY MARYSVILLE,WA • MEDFORD,OR • OLYMPIA,WA • PACIFIC,WA • PASCO,WA REDMOND,OR • SPOKANE,WA • TWIN FALLS,ID • VANCOUVER,WA WENATCHEE,WA • WILSONVILLE,OR • YAKIMA,WA SPECIFICATIONS/AVAILABLE CONFIGURATIONS & STYLE NUMBERS (2"-20") M&H AWWA C515 RESILIENT WEDGE GATE VALVES (2000) M&H Valve AWWA C515 Resilient Wedge Gate Valves Meet or Exceed the Requirements of AWWA Standard C515 Size Range Water Working Bubble Tight Hydrostatic Shell Pressure psi Seat Test psi Test psi AWWA 2"—20" 250 Water Works 250&400 500 ULFM 4"— 16" 200 Fire Protection 250&400 500 Style No. Style No. Style No. Available End Connections(No Gear) Size With With With Range 2"Nut Hand wheel Post Plate Mechanical Joint S) (no 2%") I 2"-16" 7571 7571-HW 7571-P (3"-16") Flanged Ends(NRS) 2"-16" 7561 7561-HW 7561-P (3"-l6") Flanged End X Mechanical Joint(NRS) 3"-16" 7572 7572-HW 7572-P (3"-16") Push-on (NRS)(For PVC/SDR) 2"-12" 7597 7597-HW 7597-P (3"-12") Threaded(NRS) 2"-3" 7057 7057-HW 7057-P (3"only) Threaded(NRS)(With T-Head Nut) 2"-3" 7067-07THN(With T-Head Nut) ***Threaded(OS&Y) 2"-3" N/A 7067 N/A Tyton X Tyton(NRS)(For D.I./C900) 4"-12"&16" 7901 7901-HW 7901-P(4"-12"&16") Tyton X Flange(NRS)(For D.1./C900) 4"-12" 7902 7902-HW 7902-P(4"-12") ***Flanged Ends(OS&Y) 2"-16" N/A 7068&7068A* N/A **Tapping Valve(NRS) 4"-16" 7950 7950-HW 7950-P (4"-16) M.J.Cutting-in Valve(NRS) 4"-12" 7576 7576-HW 7576-P(4"-12") ****Flanged End(Open Mitre Box) 3"-12" 7211-0 721 1-O-HW N/A ****Flanged End(Enclosed Mitre Box) 4"-12" 7211-C 7211-C-1-IW N/A Style No. Style No. Available End Connections(Bevel Gear) Size With With Range 2"Nut Hand wheel Mechanical Joint(NRS) 14-20" 7571-B 7571-BHW Flanged Ends(NRS) 14"-20" 7561-B 7561-BHW Flanged End X Mechanical Joint(NRS) 14"-20" 7572-B 7572-BHW Tyton X Tyton(NRS)(For D.1./C900) 16" 7901-B 790I-BHW Flanged Ends(OS&Y) 14"-20" 7068-B 7068-BHW **Tapping Valve(NRS) 14"-16" 7950-B 7950-BHW Style No. Style No. Available End Connections(Spur Gear) Size With With Range 2"Nut Hand wheel Mechanical Joint(NRS) 14-20" 7571-S 7571-SHW Flanged Ends(NRS) 14"-20" 7561-S 7561-SHW Flanged End X Mechanical Joint(NRS) 14"-20" 7572-S 7572-SHW Tyton X Tyton(NRS)(For D.I./C900) 16" 7901-S 7901-SHW Flanged Ends(OS&Y) 14"-20" 7068-S 7068-SHW **Tapping Valve(NRS) 14"-16" 7950-S 7950-SHW Note: 2"to 3"sizes full wall ductile iron(per AWWA Dimensions) *7068A is Tapped&Plugged in"A"Position (2"—4" ='/:"tap)(6"—12"='/a"tap) **Each size accommodates a full size diameter tapping cutter.. esulll.0% ***2"OS&Y Flanged and Threaded versions are UL Listed = 3�y, r,1L ****All other end connections available. Cvvvi 18"and larger RS gate valves will be furnished with either bevel or spur gearing. Catfied 4"11-2 . By-pass valve not required on gate valves through 24" NSF/ 81.G_ NOTE: It is recommended that valves be installed with stems vertical when used in raw sewage or sludge applications or in water with excessive sediment. Sizes 2"-12" i September 1, 2012 / C515 Gate Valves RECOMMEND SPECIFICATIONS (NRS STYLE 7000)(OS&Y STYLE 7068)(2"-20") M&H AWWA C515 RESILIENT WEDGE GATE VALVES (2000) RECOMMENDED SPECIFICATIONS(2"-20") 1. Valves shall conform to the latest revision of AWWA Standard C515 covering resilient seated gate valves for water supply service. 2. The valves shall have a ductile iron body,bonnet,and 0-ring plate. The wedge shall be totally encapsulated with rubber. 3. The sealing rubber shall be permanently bonded to the wedge per ASTM D-429. 4. Valves shall be supplied with 0-ring seals at all pressure retaining joints. No flat gaskets shall be allowed. 5. The valves shall be either non-rising stem or rising stem,opening by turning left or right,and provided with 2"square operating nut or a handwheel with the word"Open"and an arrow to indicate the direction to open. 6. Stems shall be cast copper alloy with integral collars in full compliance with AWWA. All stems shall operate with copper alloy stem nuts independent of wedge and of stem(in NRS valves). OS&Y (rising stems) shall be bronze 7. All stems shall have two 0-rings located above the thrust collar and one 0-ring below. Stem 0-rings shall be replaceable with valve fully opened and subjected to full pressure. 8. The stems on 4"-20"shall have a low torque thrust bearing located above and below the stem collar to reduce friction during operation. 9. Waterway shall be smooth,unobstructed and free of all pockets,cavities and depressions in the seat area. Valves 4"and larger shall accept a full size tapping cutter. 10. The body,bonnet and 0-ring plate shall be fusion-bonded epoxy coated,both interior and exterior on body and bonnet. Epoxy shall be applied in accordance with AWWA C550 and be NSF 61 Certified. 11. Each valve shall have maker's name,pressure rating,and year in which it was manufactured cast in the body. Country of origin to be clearly cast into body&cover castings. 12. Prior to shipment from the factory,each valve shall be tested by hydrostatic pressure equal to the requirements of AWWA C509(and UL/FM where applicable). 13. Valves shall have all component parts cast and assembled in the USA and shall be manufactured by the M&H Valve Company. NOTE: It is recommended that valves be installed with stems vertical when used in raw sewage or sludge applications or in water with excessive sediment. September 1, 2012 / C515 Gate Valves MATERIAL SPECIFICATIONS (1 of 2) M&H AWWA C515 RESILIENT WEDGE GATE VALVES (2000) CAST IRON SPECIFICATION ASTM A126 CLASS B Physical Properties Minimum tensile strength 31,000 psi Minimum transverse strength 3,300 lbs. Minimum deflection(12"Centers) .12 in Chemical Analysis(percent) Phosphorus(maximum) .75 Sulfur(maximum) .15 DUCTILE IRON SPECIFICATION ASTM A536 Physical Properties Minimum tensile strength 65,000 psi Minimum yield strength 45,000 psi SBR-STYRENE BUTADINE RUBBER-ASTM D-5000"O-Rings" & "Wedge/Seat Rubber" Hardness 78±5 100%Modulus(PSI) 800 ALTERNATE---EPDM"0-Rings"& "Wedge/Seat Rubber" Hardness 80±2 100%Modulus(PSI) 600 Tensile(PSI) 1,450 Elongation(%) 150 Compression set,ASTM D395 Method B 18%max. September 1, 2012 / C515 Gate Valves MATERIAL SPECIFICATIONS (2 of 2) M&H AWWA C515 RESILIENT WEDGE GATE VALVES (2000) STANDARD CAST BRONZE—ASTM B584 CDA836(Stem Nut) Physical Properties Minimum tensile strength 30,000psi Minimum yield strength 14,000psi Minimum elongation(in 2 inches) 20% Chemical Analysis *Copper 84.0—86.0 Lead 4.0—6.0 Tin 4.0—6.0 Nickel(maximum) 1.0 Zinc 4.0—6.0 *=CU+NI=79%Min CAST BRONZE-ASTM B584 CDA867(Stem) Physical Properties Minimum tensile strength 80,000 psi Minimum yield strength 32,000 psi Minimum elongation(in 2 inches) 15% Chemical Analysis Copper 55.0—60.0 Lead(maximum) .50—1.5 Aluminum 1.0—3.0 Iron 1.0—3.0 Nickel(maximum) 1.0 Zinc 30.0—38.0 Manganese 1.0—3.5 Tin(maximum) .2 ALTENATE CAST BRONZE-NDZ-S ASTM B763 UNS C99500(Stem) Physical Properties Minimum tensile strength 70,000 psi Minimum yield strength 40,000 psi Minimum elongation(in 2 inches) 12% Chemical Analysis Copper 82.8 Lead(maximum) .25 Aluminum(maximum) 2.0 Iron(maximum) 5.5 Nickel(maximum) 5.5 Zinc(maximum) 2.0 Silicon(maximum) 2.0 September 1, 2012 / C515 Gate Valves ITEM DESCRIPTION MATERIAL ASTM SPEC. R1 HOLD DOWN HEX BOLT 304 STAINLESS STEEL R2 HOLD DOWN BOLT WASHER 304 STAINLESS STEEL R3 OPERATING NUT OR HAND WHEEL CAST IRON ASTM A126 CLASS 8 R4 BOLTS/NUTS (STUFFING BOX) 304 STAINLESS STEEL R5 STUFFING BOX/SEAL PLATE DUCTILE IRON ASTM A536 70-50-05 R6 0—RING (STEM) QTY=3 NBR R7 0—RING (STUFFING BOX) NBR R8 THRUST WASHER DELRIN R9 STEM (AWWA GRADE C) BRONZE ASTM B584 CDA 867 R10 HEX HEAD BOLTS & NUTS 304 STAINLESS STEEL R11 COVER/BONNET DUCTILE IRON ASTM A536 70-50-05 R12 STEM NUT (AWWA GRADE A) BRONZE EPDM ASTM A584 CDA 844 R13 WEDGE/DISC/GATE CAST IRON & ?fe COATED ASTM A126 CLASS B R14 0—RING (COVER) NBR R15 BODY — ALL TYPES DUCTILE IRON ASTM A536 70-50-05 R16 POST PLATE CAST IRON ASTM A126 CLASS B R17 PIPE PLUG (OPTIONAL) GALVANIZED - C -_ Ar -____ ,\ 0 ,,,% , • ii-,_.:,,.:4„, 0 ,::4-„Tr .e.14nu 0 illkini kg � _� � 1 Millr MI a ' iiiiiiio o‘i 4, - „ ail I I.0)i OF iPIIIIIIII"11 0 1 0 DWN: TRIJ 4" THRU 1 2" M&H VALVE COMPANY DATE: 7/1/05 RESILIENT SEAT GATE VALVE ANNISTON,AIABAMA DWG. NO. C515—NRS—STYLE 7000 A DIVISION OF MCWANE INC. 7000 VALVE ASSEMBLY / MATERIAL LIST THIS ERASING NG AND ALL INFORMATION 6 OUR PROPERTY ANO 944LL NOT E USED.COPIED,OR REPMg10ED STOUT WRITTEN CONSENT.DESIGN AND RI EERION RIGIfTS RESERVED. COMPLIES WOH + 7571 WITH 2" SQUARE NUT © * ® APPLICABLE 7571 -HW WITH HANDW REQUIREMENTS OF AWWA C515 7571-P WITH POST PLATE (3"-12") APPROVED G OPTIONAL 2" SQUARE NUT HANDWHEEL m'n m ' Jill_ POSTOPTIONAL PLATE 'Maim (3"-12") � -.-_-_ 1 12" Diameter [I-11 PIIIIIMIIPIIII IT-11 I.I iim E lei ELLIPTICAL BOLT HOLES , (j- - 1H i 'WI `` • —C— F MJ END IN ACCORDANCE B NUMBER & SIZE OF BOLTS TO ANSI A21.11 A ELLIPTICAL BOLT HOLE DESIGN ALLEVIATES THE NEED FOR ANTI-ROTATIONAL BOLTS SKE IZE A 8 C D E F G H WEIGHT 2" NUT "2 8 1/4 4 1/8 2 1/2 4 1/2 10 7/8 4-5/8 7 1/4 2 25 "2 1/2 — "3 8 1/2 4 3/4 2 1/2 7 3/4 12 3/8 4-5/8 10 3 40 4 9 1/2 4 3/4 2 1/2 9 1/8 14 3/4 4-3/4 10 4 1/4 66 6 10 1/2 5 1/4 2 1/2 11 1/8 19 6-3/4 12 6 1/4 107 O 13 1/8 6 9/16 2 1/2 13 3/4 22 1/2 6-3/4 14 8 1/4 159 10 15 1/2 7 3/4 2 1/2 15 3/4 26 1/2 8-3/4 18 10 1/4 281 12 16 8 2 5/8 18 30 8-3/4 18 12 1/4 353 HANDWHEEL--ADD 1# (2" - 2 1/2"), 6.5# (3"-4"), 7#(6"), 10#(8"), 16#(10" & 12") INDICATOR POST PLATE ADD 16# (3"-12") ONLY PALLET QUANTITIES 2" NUT: 46(2 1/2"), 36(3"), 30(4"), 24(6"), 10(8)", 6(10"), 6(12") PALLET QUANTITIES HANDWHEEL: 36(2" & 2 1/2"), 30(3"), 40(4"), 18(6"), 8(8"), 6(10"), 4(12") TURNS TO OPEN: 7 3/4(2"), 8(2 1/2"), 10(3"), 13 1/2(4"), 19 1/2(6"), 25 1/2(8"), 31 1/2(10"), 37 3/4(12") "2" to 3" SIZES FULL WALL DUCTILE (PER AWWA C509 DIMENSIONS) DWN: TRIJ 2" THRU 12" M&H VALVE COMPANY DATE: 9/1/12 RESILIENT SEAT GATE VALVE ANNISTON, ALABAMA DWG. NO. C515-STYLE 7571 A DIVISION OF MCWANE INC. 7571 MJ X MJ THIS DRAWING AND ALL INPORWINRI IS OUR PROPERI'(AND SHALL NOT BE USED. COPIED.DR REPRODUCED WITHOUT WRITTEN CONSENT. DESIGN MID INVENTION RIGHTS RESERVED. m. 0tt.,.o ' T 'IT1 1 ' GLANDS APPROVED . d C153 DUCTILE IRON COMPACT FITTINGS -e------ . 1. ry t1tc1-... - , , BCOh s4. 1,1 rir _it „„kk i, Irk bs� ����� �R ...ere % las t -"kJ.- - MJ COMPACT SPLIT REPAIR GLANDS MJ GLANDS .Inside Diameter Bolt Circle Weight(lhs.) ( Size Weight Size Weight et:::14..07-.03) i+-.061 4 4.90 7.50 4 3 3 18 22 6 7.00 9.50 5 4 4 20 32 8 9.15 11.75 6 6 5 24 37 10 11.20 14.00 6 a 6 30 85 12 13.30 16.25 18 10 9 36 115 Split glands work with standard MJ gaskets and standard T-head bolts.Glands 12 10 42 180 are shipped in halves and do not need separate bolts.T-head bolts alone hold the 14 17 48 275 halves together. 16 21 - - NIJ ALLESSn,Y RI,' AND WERIEEES. 3 4 5/8 3 45-60 4.4 3.96 4 4 3/4 31/2 75-90 6.9 4.8 6 6 3/4 31/2 75-90 9.8 6.9 8 6 3/4 4 75-90 11.3 9.05 10 a 3/4 4 75-90 15.6 111 12 9 3/4 4 75-90 17.3 13.2 14 10 3/4 41/2 75-90 26.5 15.3 16 12 3/4 41/2 75-90 31.9 17.4 18 12 3/4 41/2 75-90 36.2 19.5 20 14 3/4 41/2 75-90 42.2 21.6 24 16 3/4 5 75-90 54.2 25.8 30 20 1 6 100-120 224 32 36 24 1 6 - 100-120 179.7 38.3 42 28 11/4 61/2 120-150 362 44.5 48 32 11/4 81/2 120-150 463 50.8 54 36 1 1/4 61/2 120-150 - 57.56 60 38 11/4 61/2 120-150 - 61.61 64 38 1 1/4 6 112 120-150 - 65.67 „,„iprai TYLER UNION' m Quality Waterworks Products April 30.2012 ME ROMAC INDUSTRIES,INC. Romac Style "LCT»TM ell1-800-426-9341 www.romac.com MADEINU.$.A Manhole Adapter Gasket cGasket: Virgin SBR per ;_. ASTM D 2000 M2AA 60, cci compounded for water and Manhole sewer service. Adapter NUse:The gasket is designed Gasket to be used on PVC sewer E° pipe when grouting into a '% - m concrete manhole wall. as "LCT"Gasket cross section M NOMINAL CATALOG NUMBER SIZED FOR SDR APPROXIMATE PIPE SIZE 35 PIPE O.D.s WEIGHT(Ibs.) 4" 4" LCT-Adapter Gasket 4.215 0.30# 6" 6" LCT-Adapter Gasket 6.275 0.45# 8" 8" LCT-Adapter Gasket 8.4 0.55# 10" 10" LCT-Adapter Gasket 10.5 0.70# 12" 12" LCT-Adapter Gasket 12.5 0.85# 15" 15" LCT-Adapter Gasket 15.3 1.00# 18" 18" LCT-Adapter Gasket 18.7 1.25# 21" 21" LCT-Adapter Gasket 22.05 1.50# 24" 24" LCT-Adapter Gasket 24.8 1.65# 1 27" 27" LCT-Adapter Gasket 27.96 1.85# To Order: Specify catalog number. Other sizes available, please specify pipe O.D. Price on application. Example: For 6.28 O.D.,order 6" LCT = MJ x SDR35 Transition Gasket (PVC Sewer) y Gasket: Virgin SBR per ASTM D 2000 - N. o MBA 710, compounded for water and Ira sewer service. Other compounds cs available on request. MJ x SDR35 Transition Use:The gasket is designed to be used Gasket Cn in cast iron mechanical joint fittings for Ws to PVC sewer pipe. Pressure Rating: Up to NOMINAL APPROXIMATE R 10 psi. For higher pressure PIPE SIZE CATALOG NUMBER WEIGHT(Ibs.) M ratings, contact Romac 4" 4"MJ x SDR35 Transition Gasket 0.60# Engineering. 6" 6"MJ x SDR35 Transition Gasket 0.90# �.._$°T 6"MJ x SDR35 Transition Gasket 1.15# 1 Q 10"MJ x SDR35 Transition Gasket 1.60# 12" 12"MJ x SDR35 Transition Gasket 1.90# 18" 18"MJ x SDR35 Transition Gasket 3.16# 24" 24"MJ x SDR35 Transition Gasket 5.00# To Order: Specify catalog number. 6-10 ROMAC INDUSTRIES, INC. MJ X SDR35 TRANSITION GASKET SUBMITTAL INFORMATION USE: The MJ X SDR 35 gasket is designed to be used in cast iron mechanical joint fittings for adapting to PVC sewer pipe. MATERIAL Gasket Gasket is made from virgin Styrene Butadiene Rubber (SBR) compounded for water and sewer service in accordance with ASTM D2000 MBA 710 - 90. Also available in Ethylene Propylene Diene Methylene (EPDM) and Nitrile Butadiene Rubber (NBR) on request. PRESSURE When properly installed on the correct size pipe, the Romac MJ X SDR 35 gasket can work up to 10 psi. For higher pressure ratings, contact Romac Engineering SIZES 4"—24" Romac Document Number 45-8-0044 7 15 This information is based on the best data available at the date printed above, please check with Romac Engineering Department for any updates or changes. Phone (425) 951 6200 • Toll Free 800 426 9341 • Fax (425) 951 6201 • www.romac.com 9J16' 3/4' Marked --. 1k Sewer 0 �I Storm " 0 �' C/O Vancouver Logo l6T POOSEi I'WOE x 11/4 OF£P .-2 1/2•— 2' 3/6' s•—I I Ay dolleaftits :1r1� 6 I Y g0 k�I�I0 —r� J I/T NOTES: OLYMPIC FOUNDRY INC. 18"FLANGE UP VALVE BOX&"VI"COVER MATL:Frame Cast Iron ASTM A48,CL30 44E1MM RATING: H-20 PART NO. 910 APPROX WT:Valve Box 42 Lbs,Cover 14 Lbs REV:A DATE:3/13/2003 Drawing on new template REV o�awnce A DOCUMENT APPROVED DWN:CL DATE:3/13/2003 REV: DATE: xxr- BY: DATE: CHKD:CL DATE:3113/2003 �°a DWG#:910 SCALE:N/A SHEET:1 OF 1 <.-2 DEC , qx LL3 � 1 rva�> �a":,, �� 4 ; '� 1 HD Fowler Submittal Package 7 Fought & Company Tigard , OR . r Tank Modul a a k Piping" 1 , 2 Pages , k�a I FOR: BY: I cop McKillip Excavation Inc H.D. Fowler Us PO Box 585 Chris Moore L Donald, OR 28800 SW Boberg Road ■ ** Sam McKillip ** Wilsonville, OR 97070 10 H.D. FOWLER COMPANY BELLEVUE,WA • BELLINGHAM,WA • BOISE,ID • BOZEMAN,MT • BREMERTON,WA EUGENE,OR • HAYDEN,ID • HERMISTON,OR • IDAHO FALLS,ID • JACKSON,WY MARYSVILLE,WA • MEDFORD,OR • OLYMPIA,WA • PACIFIC,WA • PASCO,WA REDMOND,OR • SPOKANE,WA • TWIN FALLS,ID • VANCOUVER,WA WENATCHEE,WA • WILSONVILLE,OR • YAKIMA,WA CflEJLIflE-Northwest, PVC D-2729 DRAIN PIPE CNWPVC-2729 FEBRUARY,2012 PLEASE ORDER BY PART NUMBER. _ WEIGHT FEET PERCENT MIN. MIN. PER PER OF BELL PART SIZE O.D. I.D. WALL 100' PALLET TL LENGTH NO. 10'BELLED END 3"SOLID 3.250 3.110 .070 48.22 1000 3.1 3.0 52075 PVC-DRAIN FIELD ASTM 0-2729 3"PERF 3.250 3.110 .070 48.22 1000 3.1 3.0 52180 SOLID & 4"SOLID 4.215 4.065 .075 67.45 900 4.2 3.5 52115 PERFORATED 14"PERF 4.215 4.065 .075 67.45 900 4.2 3.5 52210 6"SOLID 6.275 6.075 .100 134.15 350 4.0 4.0 52155 6"PERF 6.275 6.075 .100 134.15 350 4.0 4.0 52260 WEIGHT FEET PERCENT MIN. MIN. PER PER OF BELL PART SIZE O.D. I.D. WALL 100' PALLET TL LENGTH NO. 20'BELLED END 3"SOLID 3.250 3.110 .070 48.22 2000 6.2 3.0 52080 PVC-DRAIN FIELD ASTM 0-2729 3"PERF 3.250 3.110 .070 48.22 2000 6.2 3.0 52081 SOLID & 4"SOLID 4.215 4.065 .075 67.45 1200 6.2 3.5 52125 PERFORATED 4"PERF 4.215 4.065 .075 67.45 1200 6.2 3.5 52225 6"SOLID 6.275 6.075 .100 134.15 700 8.3 4.0 52158 6"PERF 6.275 6.075 .100 134.15 700 8.3 4.0 52262 FURNISHED IN 10'LENGTHS BELLED END. PERFORATIONS ARE 2 ROWS OF%"HOLES ON 5"CENTERS 120°APART IN ACCORDANCE WITH ASTM D-2729. CRESLINE-NORTHWEST,LLC. CORPORATE HEADQUARTERS:600 CROSS POINTE BOULEVARD-EVANSVILLE,IN 47715•TELEPHONE(812)428-9300 PLANT:223 MAURIN ROAD S CHEHALIS,WA 98532•TELEPHONE(360)740-0708•FAX(360)740-0721 www.cresline.com PVC-DWV CAE J L I I I b NOrthW St y CELLULAR PERFORATED CORE CNWPVC-DWVCCPERF JANUARY,2016 WEIGHT FEET PERCENT MIN. PART MIN. PER PER OF BELL NO. 20'BELLED END SIZE O.D. I.D. WALL 100' PALLET TL LENGTH PERF. PERFORATED 3" 3.500 3.068 .216 94.25 1500 5.0 4.0 51138 PVC-DWV CELLULAR CORE C. 4 4.500 4.026 .237 134.17 960 5.0 4.0 51150 DRAIN,WASTE&VENT "" ASTM F891 6 6.625 6.065 .280 236.39 400 5.6 6.0 51158 wow* PERFORATED WITH 2 ROWS OF 5/8"HOLES ON 5"CENTERS 120°APART. THE ADVANTAGES OF CELLULAR CORE • LIGHTER WEIGHT • HIGH STIFFNESS AND IMPACT STRENGTH • EXCELLENT TENSILE STRENGTH • EASIER TO CUT AND SAW • LOWER WASTE NOISE • SCHEDULE 40 • CARRIES NSF-DWV LISTING • LOWER COST • ASTM F891 NOTE:USES THE SAME FITTINGS,PVC CEMENT AND INSTALLATION PROCEDURES AS CONVENTIONAL PVC-DWV PIPE CRESLINE—NORTHWEST, LLC. CORPORATE HEADQUARTERS: 600 CROSS POINTE BOULEVARD•EVANSVILLE, IN 47715•TELEPHONE(812)428-9300 PLANT:223 MAURIN ROAD•CHEHALIS,WA 98532•TELEPHONE(360)740-0708•FAX(360)740-0721 www.cresline.com HD Fowler Submittal Package • Fought & Company Z Tigard , OR "Misc" >111 11 Pages a 0 W'` FOR: BY: 0 McKillip Excavation Inc H.D. Fowler U PO Box 585 Chris Moore ■ CI Donald, OR 28800 SW Boberg Road • ** Sam McKillip ** Wilsonville, OR 97070 0H.D. FOWLER COMPANY BELLEVUE,WA • BELLINGHAM,WA • BOISE,ID • BOZEMAN,MT • BREMERTON,WA EUGENE,OR • HAYDEN,ID • HERMISTON,OR • IDAHO FALLS,ID • JACKSON,WY MARYSVILLE,WA • MEDFORD,OR • OLYMPIA,WA • PACIFIC,WA • PASCO,WA REDMOND,OR • SPOKANE,WA • TWIN FALLS,ID • VANCOUVER,WA WENATCHEE,WA • WILSONVILLE,OR • YAKIMA,WA "B" / z """"�•.,,,� 11 GAUGE (.1196") / 304 STAINLESS STEEL / DIAMETER VARIES AVAILABLE FOR / 1.5"- 36" PIPE i / �/ // SLOTTED LEGS LEG DIMENSIONS .'' / RE-ORIENT FOR VARY �_ ADJUSTABILITY r , $ i 00 AM 0 ZMOonIMIMANOMMISiiMUM w w a.— II - O> 1 vein v viid VARIES J SLOT FOR 'B - B' TOP VIEW ANCHOR WIDTH BOLTS 1.5" (1.5" -10" BRACKETS) 2.0" (12"- 16" BRACKETS) 3.0" (18"- 24" BRACKETS) 4.0" (27" - 36" BRACKETS) �^ -' m1111MASMINUSIMINI111111SWAIM 1-:__ I- ,V 3/8" DIAMETER STAINLESS STEEL PINCH BOLT 'A - A' SPECIFICATIONS: 1) CLAMP AND BRACKETS ARE TYPE 304 RELINER / DURAN, INC. STAINLESS STEEL, 11 GAUGE (.1196"). 53 MT. ARCHER ROAD, LYME, CT. 06371 2) 3/8" 0 PINCH BOLT AND NUTS ARE TYPE (800) 508-6001 FAX: (877)434-3197 18-8 STAINLESS STEEL. WWW.RELINER.COM 3) WIDE RANGE OF SIZES FOR SDR35, DESCRIPTION DATE SCALE SCH40, CIOD-C900. STOCKED FOR 1 .5" -36" STAINLESS STEEL 6/10/16 NONE OTHER SIZES AVAILABLE. ADJUSTABLE DRAWING NUMBER CLAMPING BRACKETS BRACKET 316SS THREADED ROD STAINLESS STEEL (TYPE 316) MECHANICAL PROPERTIES FULL SIZE BOLTS,SCREWS,STUDS MACHINED TEST SPECIMENSOF BOLTS,SCREWS,STUDS YIELD TENSILE YIELD TENSILE ELONGATION IN HARDNESS STRENGTH,MIN,0.2% STRENGTH,MIN PSI STRENGTH,MIN,0.2% STRENGTH,MIN 4D,MIN, % ROCKWELL, MIN OFFSET, PSI OFFSET, PSI PSI 50,000 90,000 45,000 85,000 20 885 CHEMICAL PROPERTIES ELEMENT CHEMICAL COMPOSITION,%MAX (UNLESS MIN/MAX LIMITS GIVEN) CARBON 0.08 MANGANESE 2.00 PHOSPHORUS, MAX 0.045 SULFUR, MAX 0.030 SILICON 1.00 CHROMIUM 16.00-18.00 MOLYBDENUM 2.00-3.00 NICKEL 10.00-14.00 316SS THREADED ROD IS INTENDED FOR USE IN CORROSIVE ENVIRONMENTS. ADDED NICKEL AND MOLYBDENUM GIVE THEM SUPERIOR CORROSION RESISTANCE AND INCREASED TENSILE STRENGTH AT HIGH TEMPERATURES WHEN COMPARED TO 304SS.THE NUT NORMALLY USED WITH A 3165S THREADED ROD IS A 316SS HEX NUT. NOTE:PROPERTIES AND APPLICATION PARAMETERS ARE TYPICAL AND ARE PRESENTED IN GOOD FAITH BUT NO WARRANTY IS EXPRESSED OR IMPLIED. 31CR NUT STAINLESS STEEL (TYPE 316) MECHANICAL PROPERTIES YIELD STRENGTH, PSI TENSILE MAGNETIC PERMEABILITY REDUCTION IN ELONGATION % HARDNESS STRENGTH, PSI AREA% ROCKWELL, MIN 55,000-75,000 100,000-125,000 2.0 MAX 40 30 B100 CHEMICAL PROPERTIES ELEMENT CHEMICAL COMPOSITION,%MAX (UNLESS MIN/MAX LIMITS GIVEN) CARBON 0.08 MANGANESE 2.00 PHOSPHORUS 0.045 SULFUR 0.030 SILICON 1.00 CHROMIUM 16.00-18.00 MOLYBDENUM 2.00-3.00 NICKEL 10.00-14.00 316SS NUTS ARE INTENDED FOR USE IN CORROSIVE ENVIRONMENTS.ADDED NICKEL AND MOLYBDENUM GIVE THEM SUPERIOR CORROSION RESISTANCE AND INCREASED TENSILE STRENGTH AT HIGH TEMPERATURES WHEN COMPARED TO 304S5.3165S NUTS ARE SUPPLIED IN A HEX HEAD PATTERN PER ASME B18.2.2 STANDARD FOR SQUARE AND HEX NUTS.THE BOLT NORMALLY USED WITH A 316SS NUT IS A 316SS HEX BOLT. NOTE:PROPERTIES AND APPLICATION PARAMETERS ARE TYPICAL AND ARE PRESENTED IN GOOD FAITH BUT NO WARRANTY IS EXPRESSED OR IMPLIED. W _ ❑ ❑ ❑ C CL FULL FACE FLANGE-TYTE® CL co O 2018 EDITION P 5 co Gasket Thickness and Material: ANSI/AWN C115/A21.15 The FULL FACE FLANGE-ME Gasket is only offered in 1/8'thickness per the recommendation of Flanged Ductile Iron Pipe with Ductile-Iron ANSI/AWWA C115/A21.15 Appendix A,Sec.A.2.The FULL FACE FLANGE-TYPE Gasket is commonly or Gray-Iron Threaded Flanges. provided in SBR elastomer which is adequate for most conditions of service for potable or domestic wastewater contact.SBR elastometer carries a maximum service temperature of 150'F ANSUAWWA C110/A21.10 for water and 125'F for air applications. Ductile-Iron and Gray-Iron Fittings for Water Suggested Specification: ANsuAWWA c153/A21s3 Ductile-Iron Compact Fittings for Water Ductile Iron pipe flanged joints shall conform to ANSUAWWA CI 15/A21.15.Gaskets for Ductile Service Iron flanged joints shall be full face type SBR elastomer per ANSI/AWN C111/A21.11 and shall be 1/8"thickness.Flanged gaskets shall be the high performance type satisfying the special ANSI/AWWA C111/A21.11 requirements of ANSI/AWWA C111/A21.11 Appendix C,Sec.C.2 and have at least 131 bulb Rubber-Gasket Joints for Ductile-Iran type rings molded into both faces of the gasket.Flanged gaskets shall be U.S.Pipe Pressure Pipe and Fittings FULL FACE FLANGE-TYTE Gasket or pm-approved equal. AStE/ANSI 816.1 Assembly Procedures: Cast Iron Pipe Flanges and Flanged Fittings The FULL FACE FLANGE-TYPE Gasket should be assembled using the same general procedures ASME/ANSI 816.5 and practices for installing flanged joints.AtSUAWWA C115/A21.15 Appendix C,Sec.C.3 can Pipe Flanges and Flanged Fjttings be used for general guidance. AWWA C207 The use of flanged joints underground is NOT recommended because of the rigidity of the joint. Steel Pipe Flanges for Waterworks Service- Sizes 4 in.through 144 in. The faces of the flanges must be tree of sand,grit,grease,or other foreign matter. Flanged bolts should be tightened in a progressively crisscross pattern,such as tightening the bottom both then,the top bolt;next,the bolts at either side;and finally,the remaining bolts. This process should be repeated until all bolts are sufficiently tightened. See Table 1 on page 6 fa bolt torque requirements. Storage Recommendation: Gaskets should be stored in a cool location,out of direct sunlight and shall not come in contact with petroleum products.Gaskets should be inaccessible to vermin and should be stored away from any electrical equipment such as switchgear unless adequate precautions are taken to avoid the concentration of ozone in the storage area.Gaskets should be used on a first-in,first- out basis and should be inspected annually and prim to installation.Evidence of surface cracking,dry rot,or vermin attack is cause for discarding the gaskets and replacement with new gaskets. FILL FACE FIARGE-ME®is a Registered Trademark or United States Pipe and Foundry Company.LLC. U.S..PIPE FULL FACE FLANGE-ME Gaskets BRO-023 Revised 02.1a 1.6.11 0 C CI ❑ CL FULL FACE FLANGE-TYTE° CCM - 2018 EDITION P 6 (3) BULB TYPE RINGS r NOTE:U.S Pipe recommends the use of FULL FACE FLANGE-TYTE® Gaskets or RING FLANGE-TYTE®Gaskets with all ductile iron flanged joint products supplied by U.S.Pipe. Failure to use a flange-TYTE®gas- I ket on any fabricated pipe product 14"or larger could result in voiding the { / ` manufacturer's warranty.flange-TYTE®gaskets were designed for superi- (hI �`l`1 or sealing performance on ductile iron flanges of all types and to aid in{!}(.� .. alignment issues that may arise on projects.Flat rubber gaskets are NOT `�r, G r considered equal in performance and may not provide the sealing capabib- ; ;;�!i t �J ty requirements of a project.In addition,their use could result in unintend- ed damage to the flanges and threads of the fabricated pipe by applying excess torque to the bolts/flanges in order to seal the joint. FOIL FACE FLANGE.TYIEna is a Registered trademark of United Slates Pipe and Foundry \ Company.LLC. BOLT HOLES Table 1.FULL FACE FLANGE-TYTE' Technical Data WoridegPressure psi 150 250 350 Size BC 0D Bulb-type rings No.of Bolt Bolt Torque Inches Inches Inches each side Holes ft-lb C 4 ) 7.50 9.00 3 8 - 90 110 6 9.50 11.00 3 8 - 90 110 8 11.75 13.50 3 8 - 90 110 10 14.25 16.00 3 12 - 90 130 12 17.00 19.00 3 12 - 90 130 14 18.75 21.00 3 12 - 110 150 16 21.25 23.50 3 16 - 110 160 18 22.75 25.00 3 16 - 120 180 20 25.00 27.50 3 20 - 120 200 24 29.50 32.00 3 20 - 130 220 30 36.00 38.75 3 28 - 140 - 36 42.75 46.00 3 32 - 160 - 42 49.50 53.00 3 36 - 585 - 48 56.00 59.50 3 44 - 625 - 54 62.75 66.25 3 44 550 - - 60 69.25 73.00 3 52 600 - - 64 76.00 80.00 3 52 600 NOTE Gasket Thickness:All FULL FACE FLANGE-7YTE Gaskets are 1/8"thickness.Thinner gaskets are NOT recommended for use with Ductile Iron flanges. Material:Unless otherwise specited by the purchaser,gaskets will be furnished as SBR.Special elastomers such as neoprene,nitrite.EPOM,and fluorocarbon are available upon request.Gaskets made with special elastomers are marked with color dots.Neoprene is yellow EPOM is orange,Nitrite is greon.fluorocarbon is red. Assembly:Sea Page 4 of the FULL FACE FLANGE-TYTE Brochure for guidance. Compatibility:The FULL FACE FLANGE-TYTE Gasket is compatible with flanges conforming to ANSI/AWWA C115/621.15, ANSUAWWA C110/1421.10.ASME 816.1 class 125.and ANSI/AWWA C201 class 8,D.and E flanges. U.S.PIPE FULL FACE FLANGE-ME Gaskets BRO-023 nedsed 02.18 • ASTM A563 GR A N Fu & HEAVY HEX NUT CARBON STEEL MECHANICAL PROPERTIES GRADE NOMINAL SIZE STYLE OF PROOF LOAD STRESS, KSI HARDNESS NUT NUTS WITH NON ZINC COATED ZINC-COATED BRINELL ROCKWELL UNC,8 UN,6 NUTS NUTS MIN MAX MIN MAX UN AND COARSER PITCH THREADS A % 1-1/2 HEX 90 68 116 302 B68 C32 A '/a TO 4 HEAVY HEX 100 75 116 302 B68 C32 CHEMICAL PROPERTIES ELEMENT HEAT PRODUCT CARBON % 0.55 MAX 0.58 MAX MANGANESE % PHOSPHORUS % 0.12 MAX 0.13 MAX SULFUR % 0.15 MAX SULFUR CONTENT OF 0.23%MAX IS ACCEPTABLE WITH THE PURCHASERS APPROVAL A563 GR A NUTS ARE INTENDED FOR USE ON GENERAL STRUCTURAL AND MECHANICAL BOLTS,STUDS,AND OTHER EXTERNALLY THREADED PARTS.A563 GR A NUTS ARE SUPPLIED IN A HEX OR HEAVY HEX PATTERN PER ASME B18.2.2 STANDARD FOR SQUARE AND HEX NUTS.A563 GR A NUTS ARE NORMALLY USED WITH A307A AND A307B BOLTS AND STUDS. NOTE:PROPERTIES AND APPLICATION PARAMETERS ARE TYPICAL AND ARE PRESENTED IN GOOD FAITH BUT NO WARRANTY IS EXPRESSED OR IMPLIED. SUBMITTAL HEX BOLT T-316 - ASTM F593 18 Chromium, 10 Nickel, 2 Molybdenum (AISI T-316) Chemical Requirements • Carbon max 0.080 • Manganese max 2.00 • Phosphorous max 0.045 T'316 F-593 or Gor • Sulfur max 0.030 316 • Silicon max 1.00 • Chromium 16-18 • Nickel 10-14 • Molybdenum 2-3 Mechanical Requirements Cold Worked Hot For'ed • Hardness Rockwell Min B80-C32 B65-B95 • Tensile strength (KSI) Min 100 Max 150 (1/4" to 5/8" DIA) • Tensile strength (KSI) Min 85 Max 140 (3/4" to 1 1/2" DIA) • Tensile strength (KSI) Min 75 Max 100 (1/4" to 1 1/2" DIA) • Yield Strength (KSI) Min 45 - 65 Min 30 • Elongation 25 30 r Hex Nuts ASTM F594(ASME B18.2.2) r Heavy Hex Nuts ASTM F594 (ASME B18.2.2) I— T-316 Stainless Steel Washers r- Buried r- Submerged r Above Grade r Below Grade r Other Dimensional Data • Unless otherwise specified in the purchase order, shall be threaded in accordance with ANSI/ASME B18.2.1, page C-1, for hex cap screws (finished hex bolts). • Additional information can be found in ASTM F593, DTD 1998 (Stainless Steel Bolts, Hex Cap Screws) and in ASTM F594, DTD 1998 (Stainless Steel Nuts). T'RIPA C 475 Klug Circle-Corona,CA.92880(951)280-4488-Fax: (951)272-4445 Reg al Cij E & Cable N ® CO us 830 South West Street, Sikeston MO 63801 800-876-3020/573-472-2990 I FAX 573-471-3134 UF/TWU Irrigation Wire Description: Regency's single conductor UF/TWU Irrigation Wire is manufactured for the purpose of direct burial power wire applications in accordance with Article 339 of the National Electric Code NFPA-70. Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3 and B-8. Gauge sizes 18 thru 8 are solid conductors. Sizes 6 thru 4/0 are stranded conductors. The insulation is a high quality polyvinylchloride (PVC)for systems applications of up to 600 volts and conductor temperatures up to 60 C. The UF/TWU Irrigation Wire is constructed in accordance with Underwriters Laboratories, Inc. standard 493 and 83, as well as CSA 22.2 No. 75. Application: Suitable for use as power and control wire for irrigation systems. ram♦Construction: Conductor: Soft drawn bare copper LASTM Spec. B-3 and B-8). Solid (18 awg to 8 awg) stranded (6 awg to 4/0 awg) Insulation: Polyvinylchloride (PVC) Temperature: 60 C Voltage: 600 volts Conductor Size Insulation Thickness Colors 14 .060 1-12 C12 .060 1-12 10 .060 1-9, 11 8 .080 1-8 6 .080 1-5 4 .080 1, 2, 3, 5 2 .080 1, 2, 3, 5 1/0 .095 1, 2, 3, 5 2/0 .095 1, 2, 3, 5 `s rRt y�>f 0 '$Y ;: 1-Black, 2-White, 3-Red, 4-Blue, 5-Green;6-Yellow, 8-Orange, 9- Gray, 10-Pink, 11-Purple, 12-Tan. Material must be able to pass the following tests without showing signs of degradation: Cold Bend—The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to —25 C for four (4) hours. Electrical - AC test voltage, 60 seconds at 5000 volts. Sunlight Resistance Test - Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. Cftrislt* Christy's Detectable Marking Tape Our DETECTABLE marking tape provides far easy buried pipeline detection and below ground identification and warning.The tape can be located below ground with a non-ferrous metal detector when buried at the proper depths. All Christy's tape meets or exceeds the industry standards 4001 including the American Public Works Association(APWA)color code. - m TAPE MUST BE BURIED FLAT FOR MAXIMUM DETECTABILITY AND LINE PROTECTION. -..- CONSULT YOUR SPECIFIC LOCATOR MANUFACTURER FOR BURIAL LIMITATIONS. Tape Width Tape Bury Depth NOTE:Nat all widths are available as standard for ? - 6° 1B° the stock color/legend combinations shown. 3" 6"-28" Contact Christy's-for stock availability of specific 6" 6" 36" products.Non-stock combinations are subject to minimum requirements and plate charges. 12"or wider 6"-36" Illo 0 SPECIFICATIONS • Christy's"DETECTABLE marking tape consists of a 5.0 m8(0.005")thickness;five-ply composition; ultra-high molecular weight;100 percent virgin polyethylene;acid,alkaline and corrosion resistant • The tape tensile strength is in accordance with ASTM 0882-80A and will not he less than 7800 PSI. • Elongation properties are in accordance with ASTM D882-80A and are less than 150%at break point • Tape color&legend combination will be in accordance with APWA or local requirements. The color is . The legend reads • Tape is 5 mil overall thickness,with a.35 mil solid aluminum foil core.A.8 mil clear film,reverse printed with a repeating warning message is laminated to aluminum foil with a 3.75 m8 clear film backing. • Tape width shall be .(For best results we recommend a tape width at least/of the diameter of the pipeline being protected.A 4"diameter line would use 3"or wider tape for optimum protection).Standard widths are 2".3",6",&12". • Tape lettering shall be 1"tall on 2"detectable tape and 1.5"tall on 3"-12"tape. SPECIAL AND CUSTOM LEGENDS T.Christy Enterprises,Inc. Christy's'offers a full range of non-standard tapes,including specialty applications such as Telemetry,Irrigation 655 E.Ball Rd.•Anaheim,CA 92805 Tel:(714)507-3300•Fax:(714)507-3310 and additional water line wording.All standard combinations listed are available in at least one color/width www.TChristy.cem•800-BLU-CLUE combination.We offer specific agency legends,designations or color combinations.Custom legends can include the use of specific wording,insignias and phone numbers.Call for special pricing. AUGUST 2016 La-4031 • carSip s. How To Order Marking Tapes STANDARD COLOR/LEGEND COMBINATIONS 4/, TA.XX.XX. XXX nuns Example:TA.DT.2."RW is 2"Detectable Purple Reclaimed Water. CAUTII' ' '1ION;BUlB BURIED CAS Lt ,o. Type of Tape Width of Tape Colors Legend Cede uNE o- tION:BO Id ilill* DT-Detectable 2-2" B-Blue CP-Cathodic Protection PL-Pipeline ^r ND-Non-Detectable 3-3" P-Purple CTV-Cable N PIN-Potable Water R' # ,1TIBN;BBNo 6-6" Y-Yellow E-Electric RAW-Raw Water r 12-12" G-Green F-Fire RJ-Restrained Joint tI�N:BUl4`' R-Red FM-Force main RW-Reclaimed Water 'vs :oat'- W-White FO-Fiber Optic S-Sewer 0-Orange G-Gas STDR-Storm Drain DETECTABLE&NON-DETECTABLE BR-Brown IRR-Irrigation TEL-Telephone MARKING TAPE NPW-Non-Potable Water W-Water NS-Hydrant Not in Service NOTE:Not all widths are available as standard for STANDARD COLOR/LEGEND COMBINATIONS the stock color/legend combinations shown. Contact Christy's"for stock availability of specific Color Legend Code Printed Text on Tape products.Non-stock combinations are subject Blue BIRR "Caution knigation Line Buried Below" to minimum requirements and plate charges. Blue BNPW "Caution Nan-Potable Water Line Burled Below" Blue BPW "Caution Potable Water line Buried Below" Blue BRJ "Caution Restrained Joint Buried Below" Blue BRW "Caution Raw Water Buried Below" Blue BW "Caution Water Line Buried Below" Brown BRFM "Caution Force Main Buried Below" Green GEM "Caution Force Main Buried Below" Green GIRR "Caution Irrigation tine Buried Below" Green GNPW "Caution Non-Potable Line Buried Below" Green GPW "Caution Potable Line Buried Below" Green GRAW "Caution Raw Water Line Buried Below" Green GS "Caution Sewer Line Buried Below" Green GSTDR "Caution Storm Drain Buried Below" Orange OF0 "Caution Fiber Optic line Buried Below" Orange OTEL "Caution Telephone Line Buried Below" Orange OCP "Caution Cathodic Protection Cable Buried Below" Orange 0 CTV "Caution Cable TV Line Buried Below" Orange ORS "Caution Hydrant Not in Service Line Buried Below" Purple PIRR "Caution Irrigation Line Buried Below" Purple PRW "Caution Recycled/Reclaimed Water Line Buried Below" Purple PNPW "Caution Non-Potable Line Buried Below" Red RE "Caution Electric Line Buried Below" Red RCP "Caution Cathodic Protection Cable Buried Below"' T.Christy Enterprises,Inc. Red RF "Caution Fire Line Buried Below" 655 E.Ball Rd.•Anaheim,CA 92805 Ye0ow YE "Caution Electric line Buried Below" Yellow YG "Caution Gas Line Buried Below" Tel:(714)507-3300•Fax:(714)507-3310 Yellow YCP "Caution Cathodic Protection Buried Below" www.TChristy.cam•B00-BLU-GLUE Yellow YPL "Caution Pipeline Buried Below" AUGUST 2016 Llyd1131