Specifications OFFICE COP' M�ctioti3 001gq
COMcheck Software Version COMcheckWeb
Envelope Compliance Certificate RECEIVED
4CT 0 5 2023
Project Information CITY OF TIGARD
BUILDING DIVISION
Energy Code: 2021 IECC
Project Title: 23-615 Clario
Location: Tigard, Oregon
Climate Zone: 4c
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
Building Area Floor Area
1-Warehouse:Nonresidential 2366
Envelope Assemblies
Envelope TBD: No envelope assemblies specified
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 1 of 12
COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Information
Energy Code: 2021 IECC
Project Title: 23-615 Clario
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
Allowed Interior Lighting Power
Proposed Interior Lighting Power
Interior Lighting TBD: No lighting fixtures specified
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 2 of 12
COMcheck Software Version COMcheckWeb
Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2021 IECC
Project Title: 23-615 Clario
Project Type: Alteration
Exterior Lighting Zone 0 (Unspecified)
Construction Site: Owner/Agent: Designer/Contractor:
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/ Wattage (B X C)
Total Tradable Watts(a)= 0
Total Allowed Watts= 0
Total Allowed Supplemental Watts(b) = 350
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 350 watts may be applied toward compliance of both non-tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
Exterior Lighting TBD: Exterior lighting zone not specified (see project screen)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 3 of 12
COMcheck Software Version COMcheckWeb
Mechanical Compliance Certificate
Project Information
Energy Code: 2021 IECC
Project Title: 23-615 Clario
Location: Tigard, Oregon
Climate Zone: 4c
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
Mechanical Systems List
QuantitySystem Type & Description
1 HVAC System (Single Zone):
Heating: 1 each-Other, Gas,Capacity= 125 kBtu/h
No minimum efficiency requirement applies
Cooling: 1 each-Single Package DX Unit,Capacity=88 kBtu/h,Air-Cooled Condenser,Air Economizer
Proposed Efficiency= 11.20 EER,Required Efficiency= 11.00 EER
Proposed Part Load Efficiency= 15.00 IEER, Required Part Load Efficiency= 14.60 IEER
Fan System: FAN SYSTEM 1--Compliance(Brake HP and fan efficiency method) : Passes
Fans:
FAN 1 Supply,Single-Zone VAV, 3000 CFM,3.0 motor nameplate hp, 1.1 design brake hp(3.0 max. BHP),0.90 fan
energy index,fan exception: Fan array<=5 total HP or<=4.1 kW
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building
plans,specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been
designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
MILES HOTZ - DRAFTER 71/:, 10/5/2023
Name-Title Signature (/ Date
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 4 of 12
COMcheck Software Version COMcheckWeb
II rirl Inspection Checklist
Energy Code: 2021 IECC
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
&Req.ID
C103.2 Plans,specifications, and/or ❑Complies Requirement will be met.
[PR2]1 calculations provide all information ❑Does Not
with which compliance can be ['Not Observable
determined for the mechanical and
service water heating systems and ❑Not Applicable
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks. Hot water system sized
per manufacturer's sizing guide.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 5 of 12
•
Section
# Footing I Foundation Inspection Complies? Comments/Assumptions
& Req.JD
C403.13.2 a Snow/ice melting system and freeze ❑Complies Requirement will be met.
protection systems have sensors and ❑Does Not
C403.13.3 controls configured to limit service for
[FO9]3 pavement temperature above 50F and ❑Not Observable
outdoor temperature above 40F. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 6 of 12
Section
Plumbing Rough-in Inspection Complies? Comments/Assumptions
&Req.ID
C404.5, Heated water supply piping conforms ❑Complies Exception: Requirement does not apply.
C404.5.1, to pipe length and volume ❑Does Not
C404.5.2 requirements.Refer to section details.
[PL6]3 ['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
•
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Page 7 of 12
Data filename:
Section
# Mechanical Rough-In Inspection Compiles? Comments/Assumptions
&Req.ID
C402.2.6 Thermally ineffective panel surfaces of❑Complies Requirement will be met.
[ME41]3 sensible heating panels have ❑Does Not
insulation >= R-3.5.
❑Not Observable
❑Not Applicable
C403.8.4 !Motors for fans that are not less than ❑Complies Exception: Requirement does not apply.
[ME142]2 1/12 hp and less than 1 hp are ❑Does Not
electronically commutated motors or
have a minimum motor efficiency of ❑Not Observable
70 percent.These motors have the ❑Not Applicable
means to adjust motor speed.
C403.8.6 Each DX cooling system >65 kBtu ❑Complies Requirement will be met.
[ME143]2 and chiller water/evaporative cooling ❑Does Not
system with fans> 1/4 hp are
designed to vary the indoor fan airflow ❑Not Observable
as a function of load and comply with ❑Not Applicable
detailed requirements of this section.
C403.9 Large diameter fans where installed ❑Complies Exception: Requirement does not apply.
[ME144]2 shall be tested and labeled in ❑Does Not
accordance with AMCA 230.
['Not Observable t
[Not Applicable
C403.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values.
CME5512 ❑Does Not
❑Not Observable
❑Not Applicable
C403.5.5 Fault detection and diagnostics ❑Complies Requirement will be met.
[ME11312 installed with air-cooled unitary DX ❑Does Not
units or VRF units having
economizers. ❑Not Observable
❑Not Applicable
C403.2.2 Natural or mechanical ventilation is ❑Complies Requirement will be met.
[ME59]1 provided in accordance with ❑Does Not
;International Mechanical Code
Chapter 4. Mechanical ventilation has ['Not Observable
capability to reduce outdoor air supply;❑Not Applicable
to minimum per IMC Chapter 4.
C403.7.1 !Demand control ventilation provided ❑Complies Exception: Requirement does not apply.
[ME59]1 for spaces>500 ft2 and >15 ElDoes Not
people/1000 ft2 occupant density and
served by systems with air side Not Observable
economizer,auto modulating outside ❑Not Applicable
air damper control,or design airflow
>3,000 cfm.
C403.7.2 Enclosed parking garage ventilation ❑Complies f Exception: Requirement does not apply.
[ME115]3 'has automatic contaminant detection ❑Does Not
and capacity to stage or modulate
fans to 50%or less of design capacity. Not Observable
❑Not Applicable
C403.7.6 HVAC systems serving guestrooms in ❑Complies Exception: Requirement does not apply.
[ME141]3 'Group R-1 buildings with> 50 ❑Does Not
guestrooms: Each guestroom is
provided with controls that ❑Not Observable
automatically manage temperature ❑Not Applicable
setpoint and ventilation(see sections
'C403.7.6.1 and C403.7.6.2).
C403.7.4 Exhaust air energy recovery on ❑Complies Requirement will be met.
[ME57]1 systems meeting Table C403.7.4(1) ❑Does Not
and C403.7.4(2).
['Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 8 of 12
•
Section
Mechanical Rough-In inspection Complies? Comments/Assumptions
&Re..ID
C403.7.5 Kitchen exhaust systems comply with ❑Complies Exception: Requirement does not apply.
[ME116]3 ' replacement air and conditioned (Does Not
supply air limitations, and satisfy hood
rating requirements and maximum Not Observable
exhaust rate criteria. ❑Not Applicable
C403.5, Air economizers provided where ❑Complies Requirement will be met.
C403.5.1, required, meet the requirements for ❑Does Not
C403.5.2 design capacity, control signal,
[ME62]1 ventilation controls, high-limit shut-off, Not Observable
integrated economizer control, and ❑Not Applicable
provide a means to relieve excess
outside air during operation.
C403.5.3. Air economizers automatically reduce ❑Complies Requirement will be met.
3 outdoor air intake to the design ❑Does Not
[ME124]1 minimum outdoor air quantity when
outdoor air intake will not reduce Not Observable
cooling energy usage.See Table ❑Not Applicable
C403.5.3.3 for applicable device types
and climate zones.
C403.5.3. System capable of relieving excess ❑Complies Requirement will be met.
4 outdoor air during air economizer ❑Does Not
[ME125]1 operation to prevent over pressurizing
the building.The relief air outlet Not Observable
located to avoid recirculation into the ❑Not Applicable
building.
C403.5.3. Return,exhaust/relief and outdoor air ❑Complies Requirement will be met.
5 dampers used in economizers have ❑Does Not
[ME126]1 !motorized dampers that automatically
shut when not in use and meet ❑Not Observable
maximum leakage rates.Reference ❑Not Applicable
section C403.7.7 for details.
C403.4.1. Heating for vestibules and air curtains Complies Exception: Requirement does not apply.
4 with integral heating include ❑Does Not
[ME63]2 automatic controls that shut off the
heating system when outdoor air ❑Not Observable
temperatures>45F.Vestibule ❑Not Applicable
heating and cooling systems
controlled by a thermostat in the
vestibule with heating setpoint<=
60F and cooling setpoint>=80F.
C403.3.3 Hot gas bypass limited to: <=240 ❑Complies Requirement will be met.
[ME35]1 kBtu/h-50%>240 kBtu/h-25% ❑Does Not
❑Not Observable
❑Not Applicable
C408.2.2. Air outlets and zone terminal devices ❑Complies Requirement will be met.
1 have means for air balancing. ❑Does Not
[ME53]3 ['Not Observable
['Not Applicable
C403.11.3 Refrigerated display cases,walk-in ElComplies Exception: Requirement does not apply.
coolers or walk-in freezers served by ❑Does Not
C403.11.3 remote compressors and remote
.1, `condensers not located in a ['Not Observable
C403.11.3'condensing unit, have fan-powered ❑Not Applicable
.2 condensers that comply with Sections
[ME123]3 C403.11.3.1 and refrigeration
compressor systems that comply with
C403.11.3.2..
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 9 of 12
. Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
Req.{D
C405.7 Low-voltage dry-type distribution ❑Complies Requirement will be met.
[EL26]2 electric transformers meet the ❑Does Not
minimum efficiency requirements of
Table C405.6. ❑Not Observable
❑Not Applicable
C405.8 Electric motors meet the minimum ❑Complies Requirement will be met.
[EL2712 efficiency requirements of Tables ❑Does Not
C405.7(1)through C405.7(4).
Efficiency verified through certification ['Not Observable
under an approved certification ❑Not Applicable
program or the equipment efficiency
ratings shall be provided by motor
manufacturer(where certification
programs do not exist).
C405.9.1, Escalators and moving walks comply ❑Complies Exception: Requirement does not apply.
C405.9.2 with ASME A17.1/CSA B44 and have ❑Does Not
[EL2812 automatic controls configured to
reduce speed to the minimum [Not Observable
permitted speed in accordance with ❑Not Applicable
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
C405.10 Total voltage drop across the ❑Complies Requirement will be met.
[EL29]2 combination of feeders and branch ❑Does Not
circuits <=5%.
[Not Observable
❑Not Applicable
C405.1.1 At least 90%of dwelling unit ❑Complies Exception: Requirement does not apply.
EEL30]2 permanently installed lighting shall ❑Does Not
have lamp efficacy>=65 Im/W or
luminaires with efficacy>=45 Im/W ❑Not Observable
or comply with C405.2.4 or C405.3. ❑Not Applicable
C405.11, '50%of 15/20 amp receptacles ❑Complies Exception: Requirement does not apply.
C405.11.1,installed in enclosed offices, (❑Does Not
[EL3112 conference rooms,copy rooms, break ['Not Observable
rooms,classrooms and workstations
and >25%of branch circuit feeders ❑Not Applicable
;for modular furniture will have
"automatic receptacle control in
accordance with C405.11.1.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 10 of 12
Section
# Final Inspection Complies? Comments/Assumptions
&Req.ID
C303.3,` 'Furnished O&M manuals for HVAC ❑Complies Requirement will be met.
C408.2.5. systems within 90 days of system ❑Does Not
3 acceptance.
[F18]3 ❑Not Observable
❑Not Applicable
C403.3.1 'HVAC systems and equipment ❑Complies Requirement will be met.
[F127]3 'capacity does not exceed calculated ❑Does Not
loads.
['Not Observable
❑Not Applicable
C403.4.1 Heating and cooling to each zone is ❑Complies Requirement will be met.
[FI47 3 controlled by a thermostat control. ❑Does Not
Minimum one humidity control device
per installed [Not Observable
humidification/dehumidification ❑Not Applicable
system.
C403.4.1. Thermostatic controls have a 5 °F ❑Complies Requirement will be met.
2 deadband. ❑Does Not
[FI38]3 ❑Not Observable
❑Not Applicable
C403.4.1. Temperature controls have setpoint ❑Complies Requirement will be met.
3 overlap restrictions. ❑Does Not
[F120]3 ❑Not Observable
❑Not Applicable
C403.4.2 Each zone equipped with setback ❑Complies Exception: Requirement does not apply.
[F139]3 controls using automatic time clock or ❑Does Not
programmable control system.
['Not Observable
❑Not Applicable =:
C403.4.2. Automatic Controls: Setback to 55°F ❑Complies ,Requirement will be met.
1, (heat)and 85°F (cool); 7-day clock, 2- ❑Does Not
C403.4.2. hour occupant override, 10-hour
2 backup ❑Not Observable
[F140]3 ❑Not Applicable
C403.4.2. Systems include optimum start ❑Complies Requirement will be met.
3 controls. ❑Does Not
[FI41]3 ❑Not Observable
❑Not Applicable
C408.1.1 Building operations and maintenance ❑Complies Requirement will be met.
[FI57]1 documents will be provided to the ❑Does Not
owner.Documents will cover
manufacturers' information, ['Not Observable
'specifications, programming ❑Not Applicable
procedures and means of illustrating
to owner how building,equipment and
systems are intended to be installed,
maintained,and operated.
C408.2.1 Commissioning plan developed by ❑Complies Requirement will be met.
[F128]1 registered design professional or ❑Does Not
approved agency.
['Not Observable
❑Not Applicable
C408.2.3. HVAC equipment,systems and ❑Complies Requirement will be met.
1 'system-to-system relationships have ❑Does Not
[FI31]1 been tested to ensure proper
operation. ['Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3< Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 11 of 12
•
Section
#: Final inspection Complies? Comments/Assumptions
Req.I D
C408.2.3. HVAC and service water heating ❑Complies Requirement will be met.
2 control systems have been tested to ❑Does Not
[F110]1 ensure proper operation,calibration
and adjustment of controls. ❑Not Observable
❑Not Applicable
C408.2.3. Economizers have been tested to ❑Complies Requirement will be met.
3 ensure proper operation. ❑Does Not
(FI32]1 ❑Not Observable
❑Not Applicable
C408.2.4 Preliminary commissioning report ❑Complies Requirement will be met.
[F129]1 completed and certified by registered ❑Does Not
design professional or approved
agency. ONot Observable
❑Not Applicable
C408.2.5 Furnished HVAC as-built drawings ❑Complies Requirement will be met.
Fi7]3 submitted within 90 days of system ❑Does Not
acceptance.
❑Not Observable
❑Not Applicable
C408.2.5. An air and/or hydronic system ❑Complies Requirement will be met.
1 balancing report is provided for HVAC ❑Does Not
[FI43]1 systems. ❑Not Observable
❑Not Applicable
C408.2.5. Final commissioning report due to ❑Complies Requirement will be met.
2 building owner within 90 days of ❑Does Not
[F130]1 receipt of certificate of occupancy. [Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 23-615 Clario Report date: 10/03/23
Data filename: Page 12 of 12