Loading...
Specifications (3) MECZoi3.ae-N.g � � 1006 SW Vc.�.cns StFF B&G BUILDERS,IN I ED sSubmittal Transmittal 4244 NE Alberta St. Portland, OR 97218 OCT 0 5 2023 DATE JOBNO (503)232-6004 CITY OF TIGARD ATTENTION er 25, 2023 110-22 FAX(503)232.6177 3UILDING DIVISION Alexis Richbart RE TO Brendan Sanchez Madrona Recovery II Access Architecture 0 WE ARE SENDING YOU EAttached El Under separate cover via the following items: EjShop drawings Prints OBrochures El Samples EjSpecifications EiCopy of Letter p Calculations COPIES DATE SUBMITTAL# DESCRIPTION 09/25/23 11-REV1 Latimer HVAC-Mechanical equipment and duct design THESE ARE TRANSMITTED as checked below. For approval nApproved as noted El Resubmit _copies for approval ❑For your use EI Returned for corrections OSubmit _copies for distribution As requested DReturned for corrections D Return corrected prints • APPROVED ❑ APPROVED AS NOTED1-1 ❑ REVISE AND RESUBMIT ❑ REJECTED n ❑ VOID,NO ACTION TAKEN t , ❑ FOR RECORD ONLY,NOT REVIEWED "This review is for general conformance with PLEASE RETURN BY: ############ design concept only.Any deviation from plans or specifications not clearly noted by the Contractor has not been reviewed.Review shall not constitute a complete check of all detailed dimensions or count or serve to relieve the Contractor of contractual responsibility for any error or deviation from the contract requirements." By Brendan Sanchez Date 9/25/2023 Access Architecture,LLC SIGNED DAVID LANDAU 9/25/23 Project Superintendent 500 W 8th Street,Ste. 115E If enclosures are not as noted,kiidy notify us at once. David Landau Vancouver,WA 98660 Obtain Owner approval prior to proceeding. inft COMcheck Software Version COMcheckWeb vel Mechanical Compliance Certificate Project Information Energy Code: 2021 IECC Project Title: MADRONA NORTH Location: Tigard, Oregon Climate Zone: 4c Project Type: Addition Construction Site: Owner/Agent: Designer/Contractor: 7000 SW VARNS ST CLINT LATIMER TIGARD,Oregon 97223 LATIMER HVAC LLC CLINT@LATIMERHVAC.COM Mechanical Systems List Quantity System Type & Description 2 HVAC System(Single Zone): Cooling: 1 each-Single Package DX Unit,Capacity= 31 kBtu/h,Air-Cooled Condenser, Unknown Economizer Proposed Efficiency= 14.00 SEER2, Required Efficiency= 13.40 SEER2 Proposed Part Load Efficiency=0.00, Required Part Load Efficiency=0.00 Fan System: FAN SYSTEM 1--Compliance(Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 1 Supply,Constant Volume, 1200 CFM,0.8 motor nameplate hp,0.00 fan energy index,fan exception:Fan array <=5 total HP or<=4.1 kW 1 HVAC System(Single Zone): Cooling: 1 each-Single Package DX Unit,Capacity=27 kBtu/h,Air-Cooled Condenser, Unknown Economizer Proposed Efficiency= 13.50 SEER2,Required Efficiency= 13.40 SEER2 Proposed Part Load Efficiency=0.00, Required Part Load Efficiency=0.00 Fan System: FAN SYSTEM 2--Compliance(Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 2 Supply, Constant Volume, 1000 CFM,0.8 motor nameplate hp, 0.00 fan energy index,fan exception: Fan array<=5 total HP or<=4.1 kW 1 HVAC System(Single Zone): Cooling: 1 each-Single Package DX Unit,Capacity=42 kBtu/h,Air-Cooled Condenser, Unknown Economizer Proposed Efficiency= 13.50 SEER2, Required Efficiency= 13.40 SEER2 Proposed Part Load Efficiency=0.00, Required Part Load Efficiency=0.00 Fan System: FAN SYSTEM 3 I AC5--Compliance(Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 3 Supply,Constant Volume, 1373 CFM,0.8 motor nameplate hp,0.00 fan energy index,fan exception: Fan array<= 5 total HP or<=4.1 kW 1 HVAC System(Single Zone): Heating: 1 each-Duct Furnace,Gas,Capacity=90 kBtu/h Proposed Efficiency=80.00%Ec,Required Efficiency: 80.00%Ec Fan System: FAN SYSTEM 4 I F4--Compliance(Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 4 Supply,Constant Volume, 1230 CFM,0.5 motor nameplate hp,0.00 fan energy index,fan exception: Fan array <=5 total HP or<=4.1 kW Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 1 of 10 Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. CLINT LATIMER 10/3/2023 Name-Title Sig re Date Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 2 of 10 .4 ....(.1COMcheck Software Version COMcheckWeb Inspection Checklist Energy Code: 2021 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans,specifications,and/or ) ,Complies [PR2]i calculations provide all information Does Not with which compliance can be determined for the mechanical and ONot Observable service water heating systems and DNot Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Hot water system sized per manufacturer's sizing guide. C406 Plans,specifications,and/or Complies [PR9]1 calculations provide all information ❑Does Not with which compliance can be determined for the additional energy ONot Observable efficiency package options. [Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 3 of 10 Section # Footing/Foundation Inspection Complies? Comments/Assumptions &Req.ID C403.13.2 Snow/ice melting system and freeze DComplies protection systems have sensors and LiDoes Not C403.13.3 controls configured to limit service for [FO9)3 pavement temperature above 50F and, Not Observable outdoor temperature above 40F. l lNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 4 of 10 Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Reg.ID C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. Not Observable [PL6] of Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 5 of 10 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions &Req.ID C402.2.6 Thermally ineffective panel surfaces ofNComplies [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable ❑Not Applicable C403.8.4 Motors for fans that are not less than Complies [ME142]2 1/12 hp and less than 1 hp are ❑Does Not electronically commutated motors or have a minimum motor efficiency of [Not Observable 70 percent.These motors have the ❑Not Applicable means to adjust motor speed. C403.8.6 Each DX cooling system > 65 kBtuComplies [ME143]2 and chiller water/evaporative cooling Qrjoes Not system with fans> 1/4 hp are designed to vary the indoor fan airflow ❑Not Observable as a function of load and comply with ❑Not Applicable detailed requirements of this section. C403.9 Large diameter fans where installed ❑Complies [ME144]2 shall be tested and labeled in ❑Does Not accordance with AMCA 230. Not Observable Not Applicable C403.3 HVAC equipment efficiency verified. 1SComplies See the Mechanical Systems list for values. [ME55]2 ❑Does Not ['Not Observable ❑Not Applicable C403.2.2 Natural or mechanical ventilation is ,Complies [ME59]1 provided in accordance with ❑Does Not International Mechanical Code Chapter 4. Mechanical ventilation has ElNot Observable capability to reduce outdoor air supply'❑Not Applicable to minimum per IMC Chapter 4. C403.7.1 Demand control ventilation provided NComplies IME5911 for spaces>500 ft2 and >15 ❑Does Not people/1000 ft2 occupant density and served by systems with air side [Not Observable economizer,auto modulating outside !❑Not Applicable air damper control,or design airflow >3,000 cfm. C403.7.2 Enclosed parking garage ventilation ❑Complies [ME115]3 has automatic contaminant detection ❑Does Not and capacity to stage or modulate Not Observable fans to 50%or less of design capacity. Not Applicable C403.7.6 HVAC systems serving guestrooms in ❑Complies [ME141]3 Group R-1 buildings with> 50 ❑Does Not guestrooms: Each guestroom is Not Observable provided with controls that �Q automatically manage temperature L.Not Applicable setpoint and ventilation(see sections C403.7.6.1 and C403.7.6.2). C403.7.4 Exhaust air energy recovery on DComplies [ME57]1 systems meeting Table C403.7.4(1) ❑Does Not and C403.7.4(2). ❑Not Observable 19Not Applicable C403.7.5 Kitchen exhaust systems comply with !❑Complies [ME116]3 replacement air and conditioned ❑Does Not supply air limitations,and satisfy hood ❑Not Observable rating requirements and maximum exhaust rate criteria. lot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 6 of 10 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions &Req.ID C403.4.1. Heating for vestibules and air curtains ❑Complies 4 with integral heating include ❑Does Not (ME63]2 automatic controls that shut off the ONot Observable heating system when outdoor air temperatures>45F.Vestibule INot Applicable heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint<= 60F and cooling setpoint>= 80F. C403.3.3 Hot gas bypass limited to: <=240 NilComplies [ME35]1 kBtu/h-50% >240 kBtu/h-25% ODoes Not O Not Observable O Not Applicable C408.2.2. Air outlets and zone terminal devices Complies 1 have means for air balancing. ODoes Not [ME53]3 ONot Observable ❑Not Applicable C403.11.3 Refrigerated display cases,walk-in EComplies coolers or walk-in freezers served by ODoes Not C403.11.3 remote compressors and remote .1, condensers not located in a ONot Observable C403.11.3 condensing unit, have fan-powered Not Applicable .2 condensers that comply with Sections (ME123]3 C403.11.3.1 and refrigeration compressor systems that comply with C403.11.3.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 7 of 10 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions &Req.ID C405.7 Low-voltage dry-type distribution 1SComplies [EL26]2 electric transformers meet the ODoes Not minimum efficiency requirements of Table C405.6. ONot Observable ONot Applicable C405.8 Electric motors meet the minimum 'omplies (EL27]2 efficiency requirements of Tables ODoes Not C405.7(1)through C405.7(4). Efficiency verified through certification!ONot Observable under an approved certification ❑Not Applicable program or the equipment efficiency ratings shall be provided by motor manufacturer(where certification programs do not exist). C405.9.1, Escalators and moving walks comply :OComplies C405.9.2 with ASME A17.1/CSA B44 and have ODoes Not (EL28]2 automatic controls configured to Not Observable reduce speed to the minimumpi permitted speed in accordance with Ntlot Applicable ASME A17.1/CSA B44 or applicable local code when not conveying passengers. C405.10 Total voltage drop across theomplies [EL29]2 combination of feeders and branch ODoes Not circuits<= 5%. ONot Observable ONot Applicable C405.1.1 At least 90%of dwelling unit \Complies (EL30]2 permanently installed lighting shall ODoes Not have lamp efficacy>=65 Im/W or luminaires with efficacy>=45 Im/W ONot Observable or comply with C405.2.4 or C405.3. ONot Applicable C405.11, 50%of 15/20 amp receptacles ,Complies C405.11.1 installed in enclosed offices, Does Not [EL31]2 conference rooms,copy rooms, break rooms,classrooms and workstations ONot Observable and >25%of branch circuit feeders ONot Applicable for modular furniture will have automatic receptacle control in accordance with C405.11.1. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 8 of 10 Section # Final inspection Complies? Comments/Assumptions &Req.ID C303.3, Furnished O&M manuals for HVAC S'QComplies C408.2.5. systems within 90 days of system ❑Does Not 3 acceptance. [F18]3 ❑Not Observable ❑Not Applicable C403.3.1 HVAC systems and equipmentCompiies [FI27]3 capacity does not exceed calculated ❑Does Not loads. ❑Not Observable ❑Not Applicable C403.4.1 Heating and cooling to each zone is Complies [F147]3 controlled by a thermostat control. ❑Does Not Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification ❑Not Applicable system. C403.4.1. Thermostatic controls have a 5°F Nomplies 2 deadband. ❑Does Not [F138)3 ❑Not Observable ❑Not Applicable C403.4.1. Temperature controls have setpoint Nromplies 3 overlap restrictions. ❑Does Not [F120]3 ❑Not Observable ❑Not Applicable C403.4.2 !Each zone equipped with setback SComplies [F139)3 controls using automatic time clock or ❑Does Not programmable control system. [Not Observable ❑Not Applicable C403.4.2. Automatic Controls: Setback to 55°F ISComplies 1, (heat)and 85°F(cool); 7-day clock, 2- ODoes Not C403.4.2. hour occupant override, 10-hour 2 backup ❑Not Observable [F140]3 ❑Not Applicable C403.4.2. Systems include optimum start *Complies 3 controls. 'ODoes Not [FI41]3 ❑Not Observable ❑Not Applicable C408.1.1 Building operations and maintenance Nrompiies [FI57]1 documents will be provided to the ❑Does Not owner. Documents will cover manufacturers' information, ❑Not Observable specifications, programming ❑Not Applicable procedures and means of illustrating to owner how building,equipment and systems are intended to be installed, maintained,and operated. C408.2.1 Commissioning plan developed by Complies (F128]1 registered design professional or Does Not approved agency. [Not Observable ❑Not Applicable !' C408.2.3. HVAC equipment, systems andomplies 1 system-to-system relationships have ❑Does Not [F131]1 been tested to ensure proper operation. Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 9 of 10 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.3. !HVAC and service water heating 'omplies 2 control systems have been tested to ODoes Not [FI10]i ensure proper operation,calibration and adjustment of controls. ONot Observable ONot Applicable C408.2.4 Preliminary commissioning report Complies [FI29]1 completed and certified by registered Does Not design professional or approved agency. ONot Observable ONot Applicable C408.2.5 Furnished HVAC as-built drawingsomplies [Fl7J3 submitted within 90 days of system ODoes Not acceptance. ONot Observable ONot Applicable C408.2.5. An air and/or hydronic system 'Complies 1 balancing report is provided for HVAC ODoes Not [FI43]1 systems. ONot Observable ONot Applicable C408.2.5. I Final commissioning report due to %Complies 2 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: MADRONA NORTH Report date: 10/03/23 Data filename: Page 10 of 10 Carrier Turn to the experts Submittal Data Madrona Date: August 18, 2023 �arr/e Project: Madrona Turn to the experts Plan-1D Qty Model No Description Page System-01 1 24SCA430N003 Condensing Unit 208/230-1 ph 3 1 CVPVA3017XMC Cased Coil 6 System-02 1 24SCA436N003 Condensing Unit 208/230-1 ph 8 1 CVPVA3617XMC Cased Coil 11 System-04 1 24SCA448N003 Condensing Unit 208/230-1 ph 13 1 58SB0A090E21-16 Gas Furnace115v 1 ph 16 1 CVPVA4821XMC Cased Coil 19 o edeet1115VK2 VENTILATIONWhisperG N ArtbwCapabilty Specification Submittal Data /Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan,low sone and rated for continuous operation. ENERGY STAR®rated and certified by the Home Ventilating Institute(HVI).Evaluated by 6" duct the Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: •Enclosed brushless ECM smart motor technology rated for continuous operation cli •Adjustable ventilation rates at 110-130-150 CFM e r �- •Power rating of 120 volts and 60 Hz 1 •`- •UL and cUL listed for tub/shower enclosure when GFCI protected �1+ ��� s, •Motor equipped with thermal cutoff fuse •Removable permanently lubricated plug-in motor 73/8.= glr���II)..iraI�� �'jl� Housing: `/� ;= •Environmentally friendly 26 gauge housing using Zinc-Aluminum-Magnesium(ZAM)coating 1111111161111111 , •Integrated 6"diameter duct adapter i •Built-in damper reduces back draft and helps with blower door testing drywall as an Air •Built-in metal flange provides blocking for penetrations throwg h 101/0" io va ,Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing •Suitable for installation in ceilings insulated up to R60 •Articulating and expandable installation bracket up to 24" Grille: ` .., O.. •Attractive design using Poly Pro material •Attaches directly to housing with torsion springs 73" �._ •Includes a motion sensor cap for use as a cover when the motion sensor Plug'n PIayTM module has not been selected Warranty: •ECM Motor:6 Years from original purchase date •ALL Parts:3 Years from original purchase date Architectural Specifications: FV-1115VK2 Customizable ceiling mount ventilation fan, ENERGY STAR® rated with built-in speed selector.Select from 110/130/150 CFM with<0.3 sone as certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with 112/130/151 CFM and no more than 0.3/0.4/0.7 sones at 0.25 w.g.and 105/124/132 CFM at 0.375 w.g.Power Consumption shall be no greater than Performance Curve 6"duct 6.9/9.2/12.9 watts at 0.1 w.g.and 12.8/16.5/22.0 watts at 0.25 w.g.and 17.9/22.1/24.4 080 watts at 0.375 w.g.ENERGY STAR®rated with efficiency of no less than 16.0/14.2/11.7 CFM/watt at 0.1 w.g.and 8.7/7.9/6.8 CFM/watt at 0.25 w.g.and 5.8/5.6/5.4 CFM/watt at 0.375 w.g.The motor shall be enclosed with brushless ECM motor engineered to run `>, continuously. ECM motor speed shall automatically increase when the fan senses static °"°' - - -- —,®� pressure to maintain selected CFM.Power rating shall be 120v/60Hz.Duct diameter shall m s —,zcen °® _be less than 6".Plug'N Play" modules provide up to three additional features.Select i ` ' N —1�� from Multi-Speed with Time Delay,Condensation Sensor,and SmartAction Motion Sensor. 1° _ _ F Fan shall be RoHS Compliant and UL and cUL listed for tub/shower enclosure when GFCI s ,y f ; l protected.Also suitable for installation in ceilings insulated up to R60.. Fan can be used a° — -�t � to comply with ASHRAE 62.2,LEED,ENERGY STAR®IAP,EarthCraft,California Title-24 �J T�, ' i ,� and WA Ventilation Code. ---- ---r- I i • , i l _'.6'B0Uua T F<O ECM Motor Technology: ' 4lfFlf 6-, 6"n PR When fan senses static pressure, its speed is automatically increased to L.�.0 a --' t tom. ,-F ensure that the desired CFM is not compromised,which allows the fan to ° Adlow(CM) ,so �° cyNc-° perform as rated. 'Industry research indicates static pressure n typical installations ranges from o20'to 0.375' Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/venffans Ceiling Radiation Dampen WhisperGreen Select"is UL listed for use with the Panasonic Ceiling Radiation Damper(Model is PC-RD°5C5,sold separately). \ Whisper' r. .., .._,., e ee TM CO i FV-1115VK2 ' 0 � � � Built-In Self Adjusting VENTILATIONN Airflow Capability Plug 'N PlayTM Modules Plug'N Play'modules provide up to three additional features.Select from Multi-Speed with Time Delay,Motion Sensor,and Condensation Sensor. FV-VS15VK1: Multi-Speed with Time Delay Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0,50-120 CFM,in 10 CFM increments),then elevates to a maximum level of operation (110-130-150 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated.A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVKI: Motion Sensor Automatically activates when someone enters the room.Once the settings have been applied,the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan. FV CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects relative humidity and temperature to anticipate dew point,automatically turning the fan on to control humidity.Built-in Relative Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensation sensor is used in ..' conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates a 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select'':F -1115VK2 Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 Air Volume(CFM) 150 151 132 130 130 124 110 112 105 Noise(sones) <0.3 0.7 - <0.3 0.4 <0.3 0.3 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 6.9 12.8 17.9 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 16.0 8.7 b_8 Speed(RPM) 684 916 1084 645 900 1080 625 894 1083 Current(amps) 0.14 0.22 0.24 0.10 0.17 0.22 0.08 0.13 0.18 MAX.Current(amps) 0.24 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes "Industry research indicates static pressure in typical installations ranges from 0.20"to 0.375" Fan Specifications FV- 115VK2+FV-VS15vK1 Multi Spee. Plug'N Play"module) Static Pressure in inches w.g. 0.1 0.25_370 0.1 0.25?.370 0.1 0.25 0.37' 0.1 0.25 J 375 0.1 0.25 0.375 0.1 0.25 0 375 0.1 0.25 1375 0.1 0.25 3 37, 0.1 0.25 3377 0.1 0.25).370 Air Volume(CFM) 150 151 132 130 130 124 120 120 122 110 112 105 100 100 97 90 91 90 80 81 80 70 71 70 60 60 60 50 50 50 Noise(sones) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - <0.30.3 - <0.3 0.2 - <0.3 0.3 - <0.30.3 - <0.3 0.4 - <0.3 0.4 - <0.30.5 Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 7.7 14.0 20.5 6.9 12.8 17.9 5.5 11.0 16.0 4.7 9.7 15.0 4.2 9.0 13.9 3.7 8.1 12.2 3.3 7.2 11.2 3.0 6.4 10.2 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 15.7 8.6 6.0 16.0 8.7 5.8 18.2 9.1 6.0 19.1 9.3 6.0 19.0 9.0 5.7 19.2 8.8 5.8 18.2 8.3 5.3 17.3 8.1 5.1 Speed(RPM) 684 916 1084 645 900 1080 633 895 1086 625 894 10831 615 898 109 602 900 1099 608 912 11 591 9141109 608 9131117 609 910 1116 Current(amps) 0.14 0.22 0.24 0.10 0.17 0.22 0.09 0.15 0.21 0.08 0.13 0.1810.07 0.12 0.16 0.06 0.10 0.15 0.0510.10 0.1410.05 0.09 0.13 0.04 0.08 0.12 0.04 0.07 0.11 MAX.Current(amps) 0.33 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 'Industry research indicates static pressure in typical installations ranges from 0.20"to 0.375" Panasonic Life Solutions Company of America IAQ -- Most Efficient Division Two ✓ 2020 Two Riverfront Plaza r, Newark,NJ 07102 www.aengrge.gor us.panasonic.com/ventfans • '\ ` °S Panasonic �eeen I O IAQ19073SS r3 Carr iE r Project: Madrona Plan-ID: System-01 Model Number: 24SCA430N003 Turn to the experts Page:3 Quantity:1 AHRI Rated Cooling Performance Electrical Data AHRI Certified Reference# 208879174 Power Supply 208/230 Volts AHRI Rated Cooling 27,800 Btuh 1 Phase Capacity 60 Hertz EER 11.50 EER Minimum Circuit Ampacity 15.6 Amps SEER 13.5 SEER MOCP 25 Amps AHRI Rated M1 Cooling 28,200 Btuh EER2 ity Weight 11.50 EER2 SEER2 13.4 SEER2 Total Weight 139 lb Rated Indoor Coil: CVPVA3017XMC Factory Charge 6.00 lb Required Charge 6.00 lb Cooling Performance @ Project Parameters Net Cooling Capacity 29,220 Btuh Net Sensible Capacity 22,270 Btuh Net Latent Capacity 6,950 Btuh Total Supply Air 1000 cfm Outdoor DB Temp 95.0 °F Entoring DB Tomp 80.0 °F Entering WB Temp 67.0 °F Lcavi,iv DD T 111N 59.4 "F Leaving WB Temp 57.9 °F IField Installed Accessories Project: Madrona Plan-ID: S er System-01 Carrier Model Number: 24SCA430N003 Turn to the experts Page:4 Quantity:1 Features Single-Stage Air Conditioner Efficiency • Microtube Technology TM refrigeration system Reliability • Puron refrigerant-environmentally sound, won't deplete the ozone layer and low lifetime service cost. • Scroll compressor • Internal pressure relief valve • Internal thermal overload • Filter drier Durability WeatherArmorTm protection package: • Solid, durable sheet metal construction • Dense wire coil guard Applications • Long-line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser(See Longline Guide for more information.) • Low ambient (down to 0 F/-17.8 C) with approved low ambient accessory kits. Sound Outdoor Sound (dB) @60hz A-Weighted 63 125 250 500 1000 2000 4000 8000 73 69.5 69.5 68.9 68.9 68.5 62.8 60 57.4 1.Outdoor sound data is measure in accordance with AHRI standard 270. 2.Measurements are expressed in terms of sound power.Do not compare these values to sound pressure values because sound pressure depends on specific environmental factorswhich normally do not match individual applications.Sound power values are independent of the environment and thereforemore accurate. 3.A-weighted sound ratings filter out very high and very low frequencies,to better approximate the response of"average"human ear. A-weighted measurements for units are taken in accordance with AHRI standard 270. C = I/r..\\ 0 .Z.' S •; a ec,/ NO 1 tb: A so. 1.cEJTff2 OF GRAVITY r AIR DISCHARGE ..__. I fAIR IN AIR - ._. DISCHARGE _, mc Z• . � _ K 0- �•• N EIfLD POWER P � +' CO 4 E SUPPLY CONN. $�718'1�22 2) HOIf WITHIIII ififrtediff'hilloi n B 118"(028.6) KNOCKOUT AIR IN — 1� AIA IN FIELD CONTROL SUPPLY CONK. �� '-'- -''-'--1. `"' ...1t'l'�-jtR!t !!- ---- OW �718"({622.2J HOLE �.. _... - .. �'. P i Z ¢I3/8tQ5951 ' 1"1 co LIQUID LINE CONN.� 0 .��� ` _� J 1 3 112" 4. (9'0) (88 6) ( f H 1 4 m 0CVAPOR LINE CONN,— ' YSO. 1 13/16' _.- NZ.1) 03/8"1(9.5) IIEDOWN KNOCKOUTS 0 2 13/16"--� t2) PLACEScn •• t71.61 -AIR IN `C Cn (D 3 Dimensions (in.) b A B C D E F G H I j K 31-3/16 32-1/16 3/4 6-9/16 24-11/16 9-1/8 5/16 3 15 15-3/4 16 0 ro to ro 4' Project: Madrona Plan-ID: S stem-01 Carrier`, Model Number: CVPVA3017XMC y Turn to the experts Page:6 Quantity:1 Weight Weight I e ght 31 lb Features • Evaporator Coil with Vertex Technology with V Coil • Performance - Designed with performance in mind, this new evaporator coil offers lower pressure drops to enhance system performance and airflow characteristics. •Thermostatic Expansion Valves (TXV) -All coils have refrigerant-specific, factory-installed TXVs.Adjustable, factory set for 10 degrees of superheat. • Durable Condensate Pan -The corrosion-resistant drain pan is designed of a"Polybutylene terephthalate" material (PBT) that offers unsurpassed pan strength. It is engineered with proper slope to help ensure water drainage, improved moisture removal, and home comfort. • Condensate Drain Pan Plugs-The drain pan is supplied with three water-tight drain plugs to prevent leakage from unused drain connections. • Refrigerant Connections - Provided with industry proven sweat connections for leak-free operation to maintain system reliability.The location of the lineset connections allows for removal of the access door for easy cleaning/servicing of the coils, as well as easy access to the TXV. • Burst Pressure - Meets or exceeds burst pressure of 1900 psi, which is at least three times the pressure it would see in actual application. • UV Knockouts-The cased coils also come with factory-installed UV knockouts for quick and easy installation of UV lights. • Serviceability- Comes with a"no delta plate"for easy, quick access to the coil for service and cleaning.Also, after the door is removed, the coil is removable from the front of the unit without the use of any tools. Limited Warranty • 5 year parts limited warranty • 10 year parts limited warranty with timely registration. Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. C 3 / \I O 1 ( ., N • v k \ ' " N 4 \'/ 20-5/6" C ITSIDE OF V OUTSIDE OUTSIDE Of FLANGES O [23191 FLANGES 0.0" 18-25/32" ." - C) —77/32' [476.67 Q [13.5) OUTSIDE OF N•F 31/32" FLANGES [24.73 c g y 3w O C26.43 1 QIL 3 ; 1t 0N' 19.591 I,D. O ap o 0 110 LINE 4...l CONNECTION 4-9/32" i �\ t10a.77 1-15/16"—7 ..— [A9 57 O 0 0 Y 0 H ' r I! CP" ENE 0 A h' r,NECTION V ib'• X E ° 0 1 1 y 6.17/32" I165.7]t i —_______ ir L L SECONDARY DRAIN 1 I-15l32" Cl) C37.27 3/4" 119.051 APT PLUGGED 1/2"-+3/1" 119.05) NPT DNA! ORAIM<3) I13 31 "^ U3�07i, 1-iilti" 2.1J32" 2-7/32" E41.07 156.7] [56.T] 3"--M [74.31 F — ,O B -1 '` Dimensions (in.) A BCD E F H om 19-7/16 17-1/2 15-3/4 17-5/16 15-11/16 8-3/4 3/4 =ca • .:r V 1 �Curric f Project: Madrona Plan-ID: System-02 Model Number: 24SCA436N003 Turn to the experts Page:8 Quantity:1 AHRI Rated Cooling Performance Electrical Data AHRI Certified Reference# 208884920 Power Supply 208/230 Volts AHRI Rated Cooling 33,600 Btuh 1 Phase Capacity 60 Hertz EER 12.00 EER Minimum Circuit Ampacity 16.4 Amps SEER 14 SEER MOCP 25 Amps AHRI Rated M1 Cooling 33,200 Btuh Capacity Weight EER2 11.50 EER2 SEER2 13.4 SEER2 Total Weight 132 lb Rated Indoor Coil: CVPVA3617XMC Factory Charge 5.20 lb Required Charge 5.20 lb 1 Cooling Performance @ Project Parameters Net Cooling Capacity 34,354 Btuh Net Sensible Capacity 24,234 Btuh Net Latent Capacity 10,120 Btuh Total Supply Air 1200 cfm Outdoor DB Temp 95.0 °F Entoring DB Tomp g0.0 °F Entering WB Temp 67.0 °F Lcavii iy DD TC,111.1 01.3 "1 Leaving WB Temp 58.1 °F Field Installed Accessories Project: Madrona Plan-ID: System-02 Currie Model Number: 24SCA436N003 Turn to the experts Page:9 Quantity:1 Features Single-Stage Air Conditioner Efficiency • Microtube Technology TM refrigeration system Reliability • Puron refrigerant- environmentally sound, won't deplete the ozone layer and low lifetime service cost. • Scroll compressor • Internal pressure relief valve • Internal thermal overload • Filter drier Durability WeatherArmorn" protection package: • Solid, durable sheet metal construction • Dense wire coil guard Applications • Long-line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser(See Longline Guide for more information.) • Low ambient (down to 0 F1-17.8 C) with approved low ambient accessory kits. Sound Outdoor Sound (dB);@60hz A-Weighted 63 125 250 500 1000 2000 4000 8000 75 70.8 70.8 73.6 71.5 69.5 66.1 63.6 58.1 1.Outdoor sound data is measure in accordance with AHRI standard 270. 2.Measurements are expressed in terms of sound power.Do not compare these values to sound pressure values because sound pressure depends on specific environmental factorswhich normally do not match individual applications.Sound power values are independent of the environment and thereforemore accurate. 3.A-weighted sound ratings filter out very high and very low frequencies,to better approximate the response of"average"human ear. A-weighted measurements for units are taken in accordance with AHRI standard 270. c �� m v cu ....!.. x f., m \ NOTES: A so. 1.CENTER OFGRAVITY AIR DISCHARGE I f AIR AIR IN DISCHARGE 0 a 0... .• Z•• 3su • /ice' ==.•, ,. o �"�,, • N FIELD POWER SUPPLY CONN_ �' 7i8`fsb22.2) HOIE WITH ''. 8 118"({628.b) KNOCKOUT AIA IN AIR IN CD FIELD CONTROL SUPPLY CONN. ® I '� 'I' 'I 07/8'1022.2) HOLE wi�, NMI ni E p 0 co LIQUID LINE CONN.� 0 .��� ``�'� J 3 3,e^ 3 v2 TT IIIIIIIMIMI -- , (96.o) (68 9) ' ! iy"* _ + H4 �+ 1.. . D o� D �v o CYAPOR LINE CONN. ' Y S0. ) 1 }6 (� XSO._ (66.7) 1/2' C7 --..., (12.1) 0 3/8.109,5) TIEDOWN KNOCKOUTS K 2 13/16"--+- (2) PLACES (71,6) AIR IN `C cn N 3 1 Dimensions (in.) b N A B C D E F G H I J K 31-3/16 25-5/16 7/8 6-9/16 24-1 1/16 9-1/8 5/16 3 14-1/2 15 1 1-1/2 ON co Project: Madrona Plan-ID: System-02 CarrierModel Number: CVPVA3617XMC y Turn to the experts Page:11 Quantity:1 Weight I Weight 31 lb Features • Evaporator Coil with Vertex Technology with V Coil • Performance - Designed with performance in mind, this new evaporator coil offers lower pressure drops to enhance system performance and airflow characteristics. •Thermostatic Expansion Valves (TXV) -All coils have refrigerant-specific, factory-installed TXVs.Adjustable, factory set for 10 degrees of superheat. • Durable Condensate Pan -The corrosion-resistant drain pan is designed of a"Polybutylene terephthalate" material (PBT)that offers unsurpassed pan strength. It is engineered with proper slope to help ensure water drainage, improved moisture removal, and home comfort. • Condensate Drain Pan Plugs-The drain pan is supplied with three water-tight drain plugs to prevent leakage from unused drain connections. • Refrigerant Connections - Provided with industry proven sweat connections for leak-free operation to maintain system reliability.The location of the lineset connections allows for removal of the access door for easy cleaning/servicing of the coils, as well as easy access to the TXV. • Burst Pressure - Meets or exceeds burst pressure of 1900 psi, which is at least three times the pressure it would see in actual application. • UV Knockouts-The cased coils also come with factory-installed UV knockouts for quick and easy installation of UV lights. • Serviceability- Comes with a"no delta plate"for easy, quick access to the coil for service and cleaning.Also, after the door is removed, the coil is removable from the front of the unit without the use of any tools. Limited Warranty • 5 year parts limited warranty • 10 year parts limited warranty with timely registration. Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. = ( r'' , 0 Z s • /D ,D a _. 20-5,6" NI COUTSIDE OF S OUTSIDE OF FLANGES 0 O 15/16• - FLANGES Qom, [23.61 1I425/32. ,83 II--i7/32' OUTSIDE OF Z rt �[13.51 FLANGES 31132" # V C26.71 0. j- v 3 w 5.1/2• - _.__._____ _..--------------__-.,0 O cl3D.DI p 1-,t32" O i o [26.a f'YY DI[ O 0 D MDSb 7' 19.53, I D. 0 0 ^ �1 I 70 LINE L G .� r CONNECTION 6-9/32" 149 5] D o O O INE al'"�,,'..NECTION A D \,, 3T x E O O P' n 6-71/32" )165.77 �.�: SECONDARY DRAIN .L:�..�/ Li t 0 i•••••••� o \ `` p v C 37.27 3/4" 119.051 DPI PLUGGED CI) DRAIN 431 !/2'—� �— CO 3/4" 119.051 NPT DRAT 113.31 CA3�D76, 1-11/16" -- 2-7/32" 2-7/32" E43.03 156.7) 156.73 3-431 [76.3) F - O B N Dimensions (in.) A B C D E F H o,n 19-7/16 17-1/2 15-3/4 17-5/16 15-11/16 8-3/4 3/4 3 rt M J K N 1 • raj / � ., Project: Madrona Plan-1D: System-04 eModel Number: 24SCA448N003 Turn to the experts Page:13 Quantity:1 IAHRI Rated Cooling Performance Electrical Data AHRI Certified Reference# 208881558 Power Supply 208/230 Volts AHRI Rated Cooling 43,000 Btuh 1 Phase Capacity 60 Hertz EER 11.50 EER Minimum Circuit Ampacity 24.5 Amps SEER 13.5 SEER MOCP 40 Amps Rated Indoor Coil: CVPVA4821 XMC Rated Furnace: 58SB0A090E21-16 Weight Cooling Performance @ Project Parameters Total Weight 171 lb Factory Charge 8.90 lb Net Cooling Capacity 45,447 Btuh Required Charge 8.90 lb Net Sensible Capacity 32,038 Btuh Net Latent Capacity 13,409 Btuh Total Supply Air 1373 cfm Outdoor DB Temp 95.0 °F Entering DB Temp 80.0 °F Entering WB Temp 67.0 °F Leaving DB Temp 58.4 °F Loaving WB Tomp 66.6 °F meta instanea Accessories Carrler- Project: Madrona Plan-ID: System-04 Model Number: 24SCA448N003 Turn to the experts Page:14 Quantity:1 Features Single-Stage Air Conditioner Efficiency • Microtube Technology"' refrigeration system Reliability • Puron refrigerant-environmentally sound, won't deplete the ozone layer and low lifetime service cost. • Scroll compressor • Internal pressure relief valve • Internal thermal overload • Filter drier Durability WeatherArmorTM protection package: • Solid, durable sheet metal construction • Dense wire coil guard Applications • Long-line- up to 250 feet (76.20 m) total equivalent length, up to 200 feet(60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser(See Longline Guide for more information.) • Low ambient (down to 0 F/-17.8 C) with approved low ambient accessory kits. lSound Outdoor Sound (dB) @60hz A-Weighted 63 125 250 500 1000 2000 4000 8000 76 72.3 72.3 74.1 71.2 70.6 63.8 61.6 55.9 1.Outdoor sound data is measure in accordance with AHRI standard 270. 2.Measurements are expressed in terms of sound power.Do not compare these values to sound pressure values because sound pressure depends on specific environmental factorswhich normally do not match individual applications.Sound power values are independent of the environment and thereforemore accurate. 3.A-weighted sound ratings filter out very high and very low frequencies,to better approximate the response of"average"human ear. A-weighted measurements for units are taken in accordance with AHRI standard 270. El O !.. 7 y M W ^x en TO I NOTES: A so. -{ 1. BIEROFGRAVITY r . AIR DISCHARGE 1 / AIR a 11 ��F � AIR IN DISCHARGE f ) 3w �al I'�rruari�, / 3 • srFIELD POWER SUPPLY CONK_ n B ¢Sf7188" (628�6)HOLE KMOCKOU!( owl IIIAIR I11 . AIR IN FIELD CONTROL SUPPLY CONN. ta.#(;.11.7."" CO 0 7/8'(0 22.2) HOLE 03/849 MI co LIQUID LINE tflNN. minim K r'\\vi `, �• rIll nu { �� 1� 3 1/2" I J �� j.u:..;.,. (96.0) (68.9) I 1 / �¢ `' H 1 9,� 6 D17 CVAPOR LINE CONN. ki Y SO. 11�16" 1 1 i , i �- XSO.- , (46.7) (1/2T) G -.. �0 {Zi3I8"(Oi9:5) TIEDOWN KNOCKOUTS 2 13116" +- (2) PLACES (71.0) -AIR IN ,G �- N r-r Cp Dimensions (in.) o A BCD E F G H I J K 31-3/16 28-11/16 7/8 6-9/16 24-11/16 9-1/8 5/16 3 14-1/2 14-1/2 12-1/2 O N c mom x-• *5 to 1 _, Project: Madrona Plan-ID: S stem-04 Carrier - Model Number: 58SB0A090E21-16 y Turn to the experts Page:16 Quantity:1 IHeating Performance Supply Air Performance Heating Capacity Output 72,000 Btuh Total Supply Air 1373 cfm Heating Capacity Input 88,000 Btuh External Static Pressure 0.30 in wg. AFUE 80% Coil Static Pressure 0.34 in wg. Orientation Upflow Blower Type Direct Drive Gray Blower Speed Air flow is based on wet coil and filter Supply Air Performance is shown for Cooling Mode Electrical Data Power Supply 115 Volts 1 Phase 60 Hertz Minimum Circuit Ampacity 11 Amps MOCP 15 Amps Weight Total Weight 137 lb Field Installed Accessories arriers Project: Madrona Plan-ID: System-04 Model Number: 58SB0A090E21-16 Turn to the experts Page:17 Quantity:1 Features 4-Way Multipoise Non-Condensing 33-1/3 in. Gas Furnace Performance • Single-stage gas valve • Fixed-Speeds, Constant Torque (FCT) tapped ECM blower motor • QuieTech noise reduction system • Microprocessor based control center • Enhanced diagnostics with LED and reflective sight glass • Stores fault codes during power outages • Adjustable heating air temperature rise • Adjustable cooling airflow • Power heat igniter • Draft safeguard switch designed to ensure proper furnace venting • Inner door for tighter sealing Installation Flexibility • 4-way Multipoise furnace, 13 vent applications • Hybrid HeatTM Dual Fuel capable • Chimney friendly when used with accessory vent kit Applications • Compact design -only 33-1/3 in.tall • Propane convertible with gas conversion accessory • Convenient air purifier and humidifier connections Certification • Cabinet air leakage less than 2.0%at 1.0 in.W.C.and cabinet air leakage less than 1.4%at 0.5 in.W.C.when tested in accordance with ASHRAE standard 193. • Residential installations eligible for consumer financing through the Retail Credit Program • For California Residents: • For installation in SCAQMD only:This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450.This furnace is not eligible for the Clean Air Furnace Rebate Program:www.CleanAirFurnaceRebate.com rer Z., ..... .,, = . ,,, ..... t1 611 13 - ID 16E \ i A a •D '' -, - 1E.17 r..) ..,... CL,..... I> m 0 , — "*",0 SECTION 7 7 v. Z•• SCALE 3 16 t;,nr--- c K 1--? 1 cr CL ..4. m a 1 I 0 1 = 1 MI6 0.) 133 143.51 cn 0 oo w 3 1 0 0 03 , 0 II _... m IDP VIEW \--467/8 (0 I CI) 122 21 (:) (7 22 15/16 1 0 el ACtESSORY (2) 72 3/4 1582 61 M *--- .... N.) 1. 3 Ch 116 15//.81 -6.---2t 2 9/16 ..1 /16 [ 413 573.]1Pw 0 i54931 .1I..L 5 1/L i is6 s] A .6-19 314 11403t AIR ELDAY -.1 5 7/6 1146.51 B— • • •••••••• .......... ././.... ..,.... ..,...,... L.4. 1481 1140LITLET 41 14° 41 ••,....• ) , Ifi .1111K.11 .......•...-...Th i q.-- , 8 7/16 0113--\ o 1 ti •I. .,,,-0 7!3 ' 4) 4) ' i 4 13 16 IT 1 -'11- T ,, 11 01/2 1 1 '122121 ,1;, /1-112 %) 1213 51 i___ Y.,,ic. lop, ,,ox t--- ,---, L..._,L=,' 9 7/8 t DttATION 3 9/16 III I /1 THERMOS-AT WIFE ENTRY 110/,ej 9 11/16 o" t I256.31L J t ty' ,-01 314 1245 4) '0 _ _., CI i 1.....4 6.J 1......a 1.--.J i i • 14' -."'" -at 46r—-----i i ,, 7,16 129D /1 Er - - -----t ' 01/2 - .......-/ L...--1 L.-.1 L..-1 . . ' . I.......J 1.--.4 , ,43.1,4, (221741- ' 3/4112 71 -01 3/4 11.704 71 THERMOSTAT WIRE ENTRY 144 51 I 5 GAS ENTRY •. __,1 i C.f) (MA 1 I —1 , I I 1 1291c4/.711 li joicA LT1 oTi cor A,iR 0Nr 6A1100T:e!8__..„, 7 7. Ft!, _ (72 2) A31..ESSORY 5.< 4— r I I coe+ ... . (?2' 1- 2 5116 t 42. CD __ At:CESSORY /el I 1591 I i I 'I 0 LiSI OR . 1 (BOli 14 7/8 7 /337 31 3 = , t TH SIDES/ - 5 i v.* Pta I L________________ ' 41* ....... ...............,,......... . NNOCIS OUTS FOR-/1 271 1/IN— ...-1 [--- 21 5/8---------- 1/8 - 1549.5)BOTTOM INLET 1155.71 D 314 VENTIN6 t5 REALES/ 1.5601 1801i1 SIDES,28 318 t25 41 [ BOTTOM RETURN 119 11 SIDE !N,ET .... 1/4 121 81 1736.91 [662.01 ,,,, 26 7/16 - 1671.51 OM C 12 13)(82 = a) ...— =....4 .<CO •• -1 Carrier Project: Madrona Plan-ID: System-04 Model Number: CVPVA4821XMC Turn to the experts Page:19 Quantity:1 Weight Weight 35 lb Features • Evaporator Coil with Vertex Technology with V Coil • Performance - Designed with performance in mind, this new evaporator coil offers lower pressure drops to enhance system performance and airflow characteristics. •Thermostatic Expansion Valves (TXV) -All coils have refrigerant-specific, factory-installed TXVs.Adjustable, factory set for 10 degrees of superheat. • Durable Condensate Pan -The corrosion-resistant drain pan is designed of a"Polybutylene terephthalate" material (PBT) that offers unsurpassed pan strength. It is engineered with proper slope to help ensure water drainage, improved moisture removal, and home comfort. • Condensate Drain Pan Plugs-The drain pan is supplied with three water-tight drain plugs to prevent leakage from unused drain connections. • Refrigerant Connections - Provided with industry proven sweat connections for leak-free operation to maintain system reliability.The location of the lineset connections allows for removal of the access door for easy cleaning/servicing of the coils, as well as easy access to the TXV. • Burst Pressure - Meets or exceeds burst pressure of 1900 psi, which is at least three times the pressure it would see in actual application. • UV Knockouts-The cased coils also come with factory-installed UV knockouts for quick and easy installation of UV lights. • Serviceability- Comes with a"no delta plate"for easy, quick access to the coil for service and cleaning.Also, after the door is removed, the coil is removable from the front of the unit without the use of any tools. Limited Warranty • 5 year parts limited warranty • 10 year parts limited warranty with timely registration. Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. C O S,',. S fD x ms e " n 0 \ l C L z0-SIB" OUTSIDE O71323 AI I U/1661 1 FLANGES OUISIDE OI 0 0 FLANGES Q,.�. 4 if32' -0 E2133i1 13-25/32' 1176 67 Z.• OUTSIDE OF c K r if \I FLANGES ` 5.4l2" iiiy_____________'O Al 31/32" — 7(2N.7Jsv [110.07 " CO 51) O 0 *' 19.53) L0.LINE •^^• + DCONNECTION a I L 0 0 al O l J 1-9/32 669. -13 C100.71 J D o O O i-15t16" r- 95 H s u9 s7 ,? ,,. INE 1CD 1) .`NEOIION IN.) A 0" , ,,,., ODT X E c o !! 40 6-17/32" 1165.71 SECOND YDRAIN �!7l�,, 1-15,32" C 37,21 - 3N" U9.05) pPl PLUGGED 1 0 3/4" 119.051 NPT DRAT ORAIM 13) 3CD 1•I1/16' 1-11/16" 2-7/32" 2-7/32a [13.0J [13.0] 256 JJ 1f2'—�' (n CD C16.31 F 3 a Dimensions (in.) A BCD E F H Q- 21-15/16 21 19-1/4 20-1/16 18-5/16 10-1/2 7/8 3 W 48 a e p Carrier k 3, Turn to the experts Product Data PERFORMANCE ® i ® • Single Stage gas valve U ® • Multi 18-Speed,constant torque(MCT)ECM blower motor • QuieTechTM noise reduction system Qa®® • Microprocessor based control center ® • Adjustable heating air temperature rise ®.eflt!N • Adjustable cooling airflow • Enhanced diagnostics with easy to read 3 digit display for faults and status I ® • Stores fault codes during power outages • Power HeatTM Igniter • Draft safeguard switch designed to ensure proper furnace venting • Inner door for tighter sealing INSTALLATION FLEXIBILITY 10 • 4-way Multipoise furnace,13 vent applications • On-board NFC antenna makes setup a tap away when using the Carrier service technician app A190411 • HYBRID HEAT®Dual Fuel System compatible Representative drawing only.Some product models may vary. • All models are chimney friendly when used with accessory vent kit • Select sizes approved for twinning,refer to accessory kit listing A WARNING APPLICATIONS This furnace is not designed for use in mobile homes, trailers, or • Compact design-only 33-1/3 in.(847 mm)tall recreational vehicles. Such use could result in property damage and/or • Propane convertible with gas conversion accessory death. • Convenient Air Purifier and Humidifier connections The 58SBOB/58SB1B ComfortTM Series 4-way Multipoise Gas Furnaces CERTIFICATION feature Carrier's QuieTechTM noise reduction system for incredibly quiet induced draft operation.Applications are easy with 4-way multipoise • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4%at 0.5 in.w.c.when tested in accordance with design, through-the-furnace downflow venting, 13 different venting options,and designed for easy service access.An inner blower door is ASHRAE standard 193 provided for tighter sealing in sensitive applications. Improved • Residential installations eligible for consumer financing through the serviceability with the 3 digit status display and NFC enabled board Retail Credit Program allowing setup via the service tech app.The 58SBOB/58SB1B furnaces are approved for use with natural or propane gas,and the 58SBIB-Low NOx units are designed for California installations and can be installed in air quality management districts with a 40 ng/J NOx emissions limit. 1 4, ��nn,uvrn `�Ari ® IS09002 Quality Comfort CERTIFIED,. SERIES Use°fibs AMU Certified TM Mark indicates a mctorer'l participation in the program.For vetiticviun ofemrifumion ter individual Product. go to wwwneridirecterytn. A200123 58SBOB/58SBIB:Product Data DIMENSIONAL DATA 26 I/8 [663.61 .0fly♦, - ♦ l SECTION 2-2 ---.5 1/8 SCALE 3'.16 L130.51 2 1/16 151.61 I f NOTES: 1 1.Doors may vary by model. _ ,a"sib 2.Two additional 7/8-in.(22 mm)diameter holes are located in the top plate. 3.Minimum return-air openings at furnace,based on metal duct.If flex duct is used, see flex duct manufacturer's recommendationsor equivalent diameters. F a.For 800 C3M-16in.(406 mm)round or 141/2 x 12-in.(368 x 305 mm)rectangle. 1 b.For 1200 CFM-20-in.(508 mm)round or 141/2 x 191/2in.(368 x 495 mm)rectangle. c.For 1600 CFM-22.in.(559 mm)round or 141/2 x 22 1/16-in.(368 x 560 mm)rectangle. d.Return air above 1800 CFM may require one of the following configurations: TOP VIEW 'PM) 7/8 2 sides,l side and a bottom or bottom only for return air.See Air Delivery table in this ACCESSORY 121 document for specific use to allow for sufficient airflow to the furnace.. " z2 4s1i6 �jI^�� 316 r. [5e2.61 I�J 1 i51t6 ..-_ f511.81 22 9/16 5 15116 149.27 21 578 (573.77 (I50.11 �-3 T/16 A (549.51 r 186.81 (110231 AIR FLOW -1 -5 1l8 8 9 3/4 f t/8.51 (481.719WTLE1 1 I501.67 7(/16 07/8 •, rs1/8 i t 13116 f' l, (213.51 122 21 I. [22.21 1122.21 y fl2'71 1I t L --_ __ ACCESSORI_ , Lou T[oN BOX _ I IXERmETAT WIRE ENTRY 1 73/f6 9 1�116 47/8 - - -_ _ 1 LOCATION 99f16 9"3" 1197.811245.11 1250.71! I L5J 1243.31 -_------ /f �€AS TATrY'----- 12900.71 �112= I 273/4 1/8 -__ I 29 3/1 112.i1 Q)4 3/1 RDI.71 AIiFRNTE A •I 1194.11 THERMOSTAT MIRE ENTRY I I44.51 29 9116 JNNCT ION BON 4A5 ENTRY (750.77 LOCATION 33 1/4 -� (843.11 -___-___-_ i 01/8 [222] ri--___-___-_� 1 ACCESSORY .i._Iti_.__.. '_ 07/8 ICI 2 5/16 14 if8 [22 21 ACCESSORY is 1591 1 Z II 1�22 21 I i St07.87 ----_-_---_ 1I ACCE880AY ;BOTH SIDES/ _� (21 5/8 I 6 11B NXQCN W15 r0 22 1/16-�I-- 1549.51 BOTTOM INLET (155.71 3/4 6167(4O(5 PIACESt (5601 18078 SI0ES1 (25.41 28 3/8 BOTTOM RETURN (19.1) 1721.21 29 IO7N 26 1/16 ,- SIDE INLET 1111 (736.81 1662.01 [31.8] 26 7216 (671.51 NOTE:ALL DIMENSIONS IN INCH(MM) U.S.ECCN:Not Subject to Regulation(N.S.R.) m5W94 REV.- A210785 Dimensions A B C D VENT Unit Size TOP AND BOTTOM CONNECTION SHIP WT.LB. CABINET WIDTH OUTLET WIDTH BOTTOM FLUE INLET WIDTH SIZE (KG) COLLAR 045M14-12 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 108(49) 045M17-14 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 121 (55) 070M14-12 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 114(52) 070M17-12 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 124(56) 070M17-16 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 127(58) 070M21-16 21(533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 139.5(63) 090M17-14 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 133(60) 090M21-16 21(533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 140.5(64) 090M21-20 21(533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 147(67) 090M24-20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 150(68) 110M21-20 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 150(68) 110M24--20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 165(75) 135M24--20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102)* 167(76) 155M24--20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102)* 171 (77) •. 135 and 155 size furnaces requires a 5 or 6-in.(127 or 152 mm)vent.Use a vent adapter between furnace and vent stack.See Installation Instructions for complete installation requirements Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 2 58SB0B/58SB 1 B:Product Data MODEL NUMBER NOMENCLATURE 6 13 1,2 3 4 5 Major 7,8,9 10 11,12 Voltage 14 15,16 Gas Furnace Heating Stages Tier Min.AFUE/NOx Series Heating Input Motor Type Width (1-phase) Minor Series Airflow 59 M N 7 B 060 E 17 1 1 16 I I I 1 I I I 08=800CFM 10=1000CFM 58=80% 12=1200 CFM Non Ca lensing 0=80% 14=1400 CFM 59=9D°!o+ B=Base 1=80%Low NO C=Constant Airflow16=2000 CFM Condensing M=Modulating C=Comfort (Not Ultra L. Variable- 1 22=2200 CFM Speed 2 22=2200 CFM T=Two Stage E_ .. NOx) (VCA)ECM 3 S=Single Stage N=Infinity 2=92% V=Variable-Speed 14-14.2' 1=110V/60Hz — C=Single Stage P=Performance 5=95% 026=26,000 BTU (VCT)PWM 17-17.5" 2=230V/50Hz Comtrunicatinq U=Ultra L. 6=96% A 040=40,000 BTU M=Multi 18-Speed 21.21.0" Nor 7=97% B 060=60,000 BTU Constant Torque 24-24.5" 8=98% C -- (MCT)ECM — 155=155,000 BTU A220581 FURNACE COMPONENTS CLEARANCES INDUCER MOTOR VENT _ ELECTRIC SHOOK AND MOVING PARTS HAZARD ASSEMBLY ELBOW PRESSURE �T MAIN uMrr swrrcH INSTALLATION 1—�(BEHIND GAS VALVE) • IRWIN INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION SWITCH � �/C, \� >� ♦ ��,� This forced air furnace Ls This furnace is approved for �1�N% equipped for use with natural UPFLOW,DOWNFLOW,and �-,- j l,'' Ill ICED VENT Improper adjusbnant alteration,service, gas at altitudes 0-10,000 ft HORIZONTAL installations. FLUE COLLECTOR \�r,i i CH ice,or Installation�ca (0-3,050m). t, Clearance arrows \�', serious Injury or death An accessory kit.supplied by m3 do notcoannt woe BOX 1 �' �.:.^ c _ j furnace orientation. 0t ��/� FUME Read and fellow instructions and the mam!<adurer,shall be used GAS VALVE � �� �% SENSOR precautions in User's blforrrnatlerl manual to Convert to propane gas use �a �:{(l l it, 4.. provided with this furnace.Instigation or may be required for some v sec i IVA I _ _ . and service must be performed my a natural gas applications. K r I r _r/`i r/` ;' qualified service agency or the gas This furnace e for Indoor J ,l supplier• installation m a building Fpo� I�G'7 __. � ., constructed on site. MANUAL RESET ■ _ V GAS MANIFOLD a* .' This furnace may be installed 00 LIMIT SWATCHES ���❑-i1* tilt, �' on at minimum flooring in alceve "� �t� `1 3 _ Check entire gas assembly for leaks after or closet at minimum clearance �.0 lighting this appliance. y as indicated by the diagram HOT SURFACE — INSTALLATIONINN hum combustible material. I IGNITOR �� �'...' This furnace may be used with Clearance n inches ' 1.This accordancefurnace must be installed in a Type is Vent and may be YeMCleerenr0eto oorrtusl61�: o GAS BURNER with the manufacturers vented in common with other t 0 instructions and local codes.In the gas fired appilencas. FarSigle Wal serfs 6 Niches(6 po) BLOWER absence of local codes,follow the National ForType B-1 kenttype 1 ndr(1 po) DOOR SAFETY Fuel Gas Code ANSI Z223.1/NFPA54 SWITCH , - or CSA B-149.1 Gas Installation Code. MINIMUM INCHES CLEARANCE TO FlJlirlACE j '-'® 2.This furnace must be installed so there am COMBUSTIBLE CONSTRUCTION CONTROL I► provisions for combustion and ventilation BOARD 4 - BLOWER AND air.See manufacturer's installation DOWNFLOW POSRIONS: � ' !i' MOTOR information provided with this appliance. t Installation on non-combustible floors only. OPERATION Fo stellatwn on cer reu ble flooring only when installed on I)=I _ I ! This furnace is equipped with manual reset a rlmanufecturer approved special base kit or manufacturer limit switch(es)in burner compartment to recerrrtcerded assembly protect against overheat conditions that 0 18 inches front clearance required for alcove. �J: can result from inadequate combustion air * Indicates s supply or blocked vent conditions. supply or return sides when furnace is in i i.Do not bypass limit switches. the horizontal position.Line contact only permissible \�'-'I!. 2.If a limit opens,caN a quaBified between lines forced by intersections of the Top and 1111 n• �� .. 4serviceman to correct the condition two Sides of the furnace jacket,and building joists, ` and reset limit switch. studs or framing. sereawr REVF A190086 A220231 Representative drawing only,some models may vary. The furnaces are factory shipped for use with natural gas.These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 3 58SB0B/58SBIB:Product Data SPECIFICATIONS UNIT SIZE 045M14--12 045M17--14 070M14--12 070M17--12 070M17-16 070M21--16 090M17--14 HEATING AND CAPACITY AND EFFICIENCY All Standard 44,000 44,000 66,000 66,000 66,000 66,000 88,000 Input BTUh* Low NOx-Upflow Low NOx-Dwnflw/Hz 42,000 42,000 63,000 63,000 63,000 63,000 84,000 All Standard 36,000 35,000 54,000 54,000 54,000 53,000 71,000 Output Capacity(BTUh)t Low NOx-Upflow LowNOx-Dwnflw/Hz 34,000 34,000 51,000 51,000 51,000 51,000 68,000 Certified Temperature Rise Range-°F(°C) 30-60 30-60 30-60 30-60 25-55 25-55 40-70 AFUEt (17-33) (17-33) (17-33) (17-33) (14-31) (14-31) (22-39) 80% AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Heating 0.10 0.10 0.12 0.12 0.12 0.12 0.15 Static Pressure Cooling 0.50 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM @ Rated Heating 715 720 1075 1110 1310 1290 1230 ESP(CFM)# Cooling 175-1095 210-1285 180-1115 155-1160 235-1700 210-1820 330-1490 Direct Drive Motor HP 1/3 1/2 1/3 1/3 3/4 3/4 1/2 Motor Full Load Amps 4.4 6.7 4.4 4.4 8.8 8.8 6.7 Heating Blower Control(Htg OFF-Delay) Adjustable:90,120(factory-set),150,180 seconds Cooling Blower Control(Gig OFF-Delay) Adjustable:90(factory-set),5,30 seconds Blower Wheel Diameter x Width-In.(mm) 10x6 10x8 10x6 10x8 11x8 10x10 10x8 (254x152) (254x203) (254x152) (254)(203) (279x203) (254)(254) (254)(203) Air Filtration System Field Supplied Filter Filter used for Certified Waft Data 325531-40'* ELECTRICAL DATA Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 6.0 7.9 6.0 5.9 10.4 10.4 8.2 Unit Ampacity 8.3 10.7 8.3 8.2 13.8 13.8 11.0 Maximum Wire Length(Measure 1 way in Ft/M) 44/13.6 34/10.6 44/13.6 45/13.80 26/8.2 26/8.2 34/10.3 Minimum Wire Size AWG 14 14 14 14 14 14 14 Max.Fuse/Ckt Bkr Size (Time-Delay Type Amps 15 15 15 15 15 15 15 Recommended) Transformer Capacity(24 VAC output) 40VA External Control Power Heating 12VA Available Cooling 35VA GAS CONTROLS Burners 2 2 3 3 3 3 4 Gas Connection Size 1/2 in.NPT Gas Valve(Redundant) Mfr WhiteRodgers" Min.inlet pressure (in.w.c.) 4.5(Natural Gas) Max.inlet pressure (in.w.c.) 13.6(Natural Gas) Ignition Device Silicon Nitride Factory installed orifice Size 43 CONNECTIONS Communication System None Thermostat Connections G,C,W,Y,R Accessory Connections EAC-1 (115 VAC);HUM(24 VAC);1-STG AC(via Y) *. Gas input ratings are certified for elevations to 2000 ft.(610 M).In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. t. Capacity in accordance with U.S.Government DOE test procedures. t. Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide,high efficiency media filter. **. See Accessory List for part numbers available. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 4 58SB0B/58SB1B:Product Data UNIT SIZE 090M21--16 090M21-20 090M24--20 110M21-20 110M24-20 135M24--20 155M24--20 HEATING AND CAPACITY AND EFFICIENCY All Standard 88,000 88,000 88,000 110,000 110,000 132,000 154,000 Input BTUh* Low NOx-Upflow Low NOx-Dwnflw/Hz 54,000 84,000 - 105,000 105,000 126,000 147,000 All Standard 72,000 71,000 72,000 90,000 90,000 107,000 125,000 Output Capacity(BTUh)t Low NOx-Upflow Low NOx-Dwnflw/Hz 68,000 68,000 - 85,000 85,000 102,000 119,000 Certified Temperature Rise Range-°F(°C) 35-65 25-55 30-60 30-60 30-60 40-70 45-75 AFUEt (19-36) (14-31) (17-33) (17-33) (17-33) (22-39) (25-42) 80% AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Heating 0.15 0.15 0.15 0.20 0.20 0.20 0.20 Static Pressure Cooling 0.50 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM @ Rated Heating 1325 1645 1515 1840 1970 1805 1945 ESP(CFM)# Cooling 315-1565 325-2315 265-1980 420-2350 400-2005 290-1925 290-1985 Direct Drive Motor HP 1/2 1 3/4 1 3/4 3/4 3/4 Motor Full Load Amps 6.7 11.5 8.8 11.5 8.8 8.8 8.8 Heating Blower Control(Htg OFF-Delay) Adjustable:90,120(factory-set),150,180 seconds Cooling Blower Control(Clg OFF-Delay) Adjustable:90(factory-set),5,30 seconds Blower Wheel Diameter x Width-In.(mm) 10x10 11x11 11x11 11x11 11x11 11x11 11x11 (254)(254) (279)(279) (279)(279) (279)(279) (279)(279) (279)(279) (279)(279) Air Filtration System Field Supplied Filter Filter used for Certified Watt Data 325531-40** ELECTRICAL DATA Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 8.2 13.9 10.7 14.4 11.1 11.0 10.7 Unit Ampacity 11.0 18.1 14.1 18.6 14.6 14.4 14.1 Maximum Wire Length(Measure 1 way in Ft/M) 34/10.3 31/9.6 26/8.0 30/9.4 25/7.7 25/7.8 26/8.0 Minimum Wire Size AWG 14 12 14 12 14 14 14 Max.Fuse/Ckt Bkr Size (Time-Delay Type Amps 15 20 15 20 15 15 15 Recommended) Transformer Capacity(24 VAC output) 40VA External Control Power Heating 12VA Available Cooling 35VA GAS CONTROLS Burners 4 4 4 5 5 6 6 Gas Connection Size 1/2 in.NPT Gas Valve(Redundant) Mfr WhiteRodgersTM Min.inlet pressure (in.w.c.) 4.5(Natural Gas) Max.inlet pressure (in.w.c.) 13.6(Natural Gas) Ignition Device Silicon Nitride Factory installed orifice Size 43 CONNECTIONS Communication System None Thermostat Connections G,C,W,Y,R Accessory Connections EAC-1 (115 VAC);HUM(24 VAC);1-STG AC(via Y) *. Gas input ratings are certified for elevations to 2000 ft.(610 M).In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. t. Capacity in accordance with U.S.Government DOE test procedures. t. Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide,high efficiency media filter. **. See Accessory List for part numbers available. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 5 58SBOB/58SB1B:Product Data AIR DELIVERY (with filter) Air Delivery-CFM(with filter)* Unit Size Airflow Setting Default Setting External Static Pressure(in.w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1 Constant Fan 455 385 320 250 175 — -- — — — 2 490 425 360 300 225 150 -- — -- — 3 535 480 415 360 305 230 160 — — — 4 565 510 450 395 345 285 215 135 -- — 5 605 555 500 445 390 345 285 215 145 — 6 645 595 545 490 440 395 350 290 225 155 7 695 645 600 550 500 455 410 370 310 255 8 Heating 715 670 625 575 530 485 440 400 355 290 045M14--12 9 770 730 685 640 595 555 510 470 430 390 10 825 780 740 700 660 615 575 535 500 460 11 870 830 795 755 720 680 640 600 560 525 12 920 880 845 810 775 735 700 660 625 590 13 965 930 895 855 825 790 755 720 685 650 14 1005 970 935 905 875 840 805 770 740 705 15 1055 1020 990 960 930 895 865 835 800 770 16 1105 1070 1040 1010 980 950 925 895 860 830 17 1125 1095 1065 1035 1005 975 950 920 890 860 18 Cooling 1210 1180 1150 1120 1095 1065 1040 1010 980 945 1 Constant Fan 495 425 345 270 210 135 -- — — — 2 540 475 400 330 270 205 135 — -- -- 3 580 520 455 380 320 260 200 160 — — 4 635 575 520 450 385 330 275 215 155 — 5 685 630 570 515 450 390 340 290 235 180 6 Heating 720 665 615 560 505 445 395 345 295 245 7 770 720 665 615 565 505 450 400 355 310 8 830 785 735 690 640 590 535 485 440 395 045M17-14 9 880 840 790 745 705 660 610 555 510 465 10 945 905 860 815 775 735 690 645 595 ' 550 11 1005 965 920 880 840 800 760 725 680 630 12 1060 1025 985 940 905 865 825 790 750 710 13 1120 1085 1050 1010 970 935 900 865 830 795 14 1170 1135 1100 1065 1030 995 960 925 890 855 15 1235 1205 1170 1135 1100 1065 1035 1000 965 915 16 1295 1265 1235 1200 1170 1135 1105 1075 1020 930 17 1365 1335 1305 1270 1240 1210 1180 1125 1035 930 18 Cooling 1460 1420 1375 1330 1285 1235 1190 1130 1035 930 1 Constant Fan 465 400 330 250 180 115 -- — — 2 500 440 370 295 225 165 115 - — - 3 550 490 430 365 300 235 175 130 - — 4 595 540 485 425 355 295 240 185 135 — 5 635 580 530 475 420 355 300 245 195 145 6 675 ' 625 575 525 470 410 355 300 250 205 7 715 670 625 575 525 475 420 370 320 270 8 760 720 675 630 585 535 490 435 390 340 070M14-12 9 805 765 725 685 640 595 550 505 455 410 10 855 820 780 740 700 660 615 575 530 485 11 905 870 835 795 760 720 685 645 600 560 12 950 915 880 845 810 775 740 + 700 665 625 13 1005 970 940 905 870 840 805 770 735 700 14 1055 1020 990 960 930 895 865 830 800 765 15 Heating 1085 1055 1025 995 965 935 900 870 840 810 16 1120 1090 1060 1030 1000 970 940 910 880 850 17 1150 1120 1095 1065 1035 1005 975 945 920 890 18 Cooling 1220 1195 1170 1140 1115 1090 1060 1035 1005 970 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 6 58SB0B/58SB1B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure Sin.w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1 Constant Fan 475 385 300 220 155 - -- — — 2 515 430 350 275 200 130 -- — — — 3 565 490 410 340 270 205 140 — — — 4 610 540 470 400 335 265 210 150 — — 5 655 590 525 455 395 330 270 215 155 — 6 700 635 570 505 445 385 325 270 220 165 7 740 685 620 560 500 445 390 335 280 235 8 790 735 675 620 565 510 455 400 350 300 070M17-12 9 835 785 730 675 620 570 515 465 415 365 10 880 830 780 725 675 625 575 525 480 430 11 935 890 840 790 740 690 645 595 550 505 12 985 940 895 845 800 750 705 665 620 575 13 1035 990 950 900 855 810 770 730 685 640 14 1080 1040 995 950 910 865 825 785 745 705 15 Heating 1120 1075 1035 995 950 910 870 830 790 750 16 1175 1'f40 1100 1060 1020 980 940 905 865 830 17 1225 1190 1155 1115 1080 1040 1000 965 930 895 18 Cooling 1300 1265 1230 1190 1160 1120 1085 1050 1015 980 1 Constant Fan 545 465 385 310 235 15o -- — — — 2 605 535 455 385 315 250 175 - -- -- 3 665 595 530 460 395 330 270 205 — — 4 740 675 615 550 490 430 370 315 255 190 5 810 750 690 635 570 515 460 405 355 305 6 870 815 760 705 650 595 545 490 440 390 7 955 900 850 795 745 695 645 595 545 495 8 1025 975 925 880 835 785 735 685 645 595 070M17-16 9 1095 1050 1005 955 915 870 820 ' 770 730 685 10 1175 1135 1090 1045 1005 960 920 875 830 790 11 1220 1180 1135 1095 1055 1015 975 935 890 850 12 Heating 1320 1285 1245 1205 1170 1130 1095 1055 1015 980 13 1390 1355 1315 1280 1245 1210 1170 1135 1100 1065 14 1475 1435 1405 1370 1335 1300 1265 1235 1200 1165 15 1550 1520 1485 1450 1415 1385 1350 1320 1290 1260 16 1630 1600 1570 1540 1510 1480 1450 1420 1390 1365 17 1705 1675 1640 1815 1590 1560 1535 1505 1480 1455 18 Cooling 1840 1810 1775 1735 1700 1660 1620 1580 1540 1500 1 Constant Fan 590 495 390 290 210 120 — — — — 2 665 580 485 390 300 225 145 - — — 3 730 655 565 480 385 310 245 170 — — 4 820 750 675 595 520 435 360 300 235 165 5 875 810 740 665 595 515 435 370 315 250 6 950 885 830 760 695 625 550 480 410 360 7 1045 985 930 875 810 750 685 620 555 490 8 1140 1085 1030 980 925 865 810 750 695 635 070M21--16 9 1200 1145 1095 1050 ' 1000 945 885 835 780 730 10 Heating 1300 1250 1195 1155 1110 1065 1015 960 910 865 11 1370 1320 1275 1230 1190 1150 1105 1055 1005 960 12 1455 1410 1365 1325 1285 1245 1205 1165 1115 1070 13 1535 1490 ' 1450 1415 1375 1340 1305 1265 1225 1185 14 1615 1575 1535 1495 1460 1425 1390 1355 1320 1285 15 1705 1670 1635 1600 1565 1535 1505 1470 1435 1400 16 1775 1745 1710 1680 1650 1620 1590 1560 1530 1505 17 1870 1840 1810 1780 1750 1725 1705 1670 1630 1530 18 Cooling 2025 1975 1925 1875 1820 1770 1725 1680 1630 1535 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 7 58SBOB/58SB1B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure Sin.w.c.) 0.1 0.2 0.3 0.4 0. 0.6 I 0.7 0.8 0.9 1 1 Constant Fan 670 595 485 405 330 245 190 130 — 2 705 635 535 450 380 305 235 180 125 3 760 695 625 520 450 380 310 245 195 145 4 810 750 685 585 515 450 385 320 260 210 5 860 800 745 675 580 510 450 390 325 270 6 910 855 800 740 650 580 515 460 400 345 7 950 900 850 790 730 640 575 515 465 410 8 1025 975 925 875 820 740 670 615 560 510 090M17--14 9 1075 1030 985 935 885 835 745 690 630 580 10 1140 1095 1050 1005 960 910 855 775 715 665 11 1210 1165 1125 1085 1040 995 950 895 815 760 12 Heating 1255 1210 1170 1130 1085 1045 1000 955 880 820 13 1280 1235 1200 1160 1115 1075 1030 990 925 855 14 1340 1300 1265 1225 1185 1145 1105 1065 1025 965 15 1410 1370 1335 1300 1265 1225 1190 1150 1110 1070 16 1475 1440 1405 1370 1335 1300 1265 1225 1190 1150 17 1550 1515 1480 1445 1415 1380 1345 1310 1270 1235 18 Cooling 1620 1585 1555 1520 1490 1460 1425 1375 1315 1255 1 Constant Fan 685 585 490 395 315 240 170 — 2 745 660 560 480 390 320 250 185 — — 3 810 725 635 550 475 395 325 265 200 4 860 785 700 615 540 465 395 335 275 215 5 915 845 765 680 610 535 465 400 345 285 6 980 910 840 765 690 620 555 490 425 370 7 1040 980 910 840 770 700 635 575 510 450 8 1100 1040 975 910 840 770 710 650 590 530 090M21--16 9 1170 1110 1055 995 930 870 800 745 685 630 10 1225 1170 1110 1055 995 930 865 810 755 700 11 1295 1245 1195 1135 1085 1025 970 905 850 795 12 1315 1265 1215 1160 1110 1055 1000 935 880 830 13 Heating 1350 1300 1250 1195 1145 1090 1035 975 915 865 14 1420 1375 1330 1280 1230 1185 1130 1075 1020 960 15 1495 1455 1405 1360 1315 1270 1220 1170 1120 1060 16 1565 1525 1480 1435 1395 1350 1305 1260 1210 1160 17 1645 1605 1565 1525 1480 1435 1390 1345 1300 1250 18 Cooling 1725 1680 1645 1605 1565 1520 1480 1420 1340 1260 1 Constant Fan 770 655 540 430 325 195 -- — — 2 850 745 640 535 435 340 210 - — 3 925 825 725 625 530 435 345 230 — 4 1030 940 845 755 665 575 490 405 315 185 5 1120 1040 950 865 780 700 615 540 455 380 6 1210 1130 1050 970 895 810 735 655 580 510 7 1285 1215 1140 1065 990 915 840 765 690 620 8 1385 1320 1250 1180 1110 1040 975 900 835 765 090M21-20 9 1480 1415 1355 1290 1215 1155 1090 1025 960 895 10 1570 1510 1450 1390 1325 1260 1200 1140 1080 1015 11 Heating 1675 1615 1560 1505 1450 1390 1330 1270 1210 1155 12 1775 1720 1670 1615 1560 1510 1450 1395 1340 1285 13 1865 1815 1765 1715 1660 1610 1555 1500 1450 1395 14 1965 1920 1875 1825 1780 1730 1680 1630 1580 1535 15 2075 2030 1985 1940 1895 1845 1805 1760 1710 1660 16 2170 2135 2090 2050 2005 1965 1925 1880 1835 1790 17 Cooling 2270 2225 2190 2150 2115 2075 2035 2000 1960 1920 18 2485 2445 2410 2365 2315 2265 2215 2160 2105 2050 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 8 58SB0B/58SB1B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure(in.w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1 Constant Fan 735 610 485 375 265 135 -- - -- - 2 830 720 610 495 395 295 175 - -- - 3 890 790 680 570 470 380 280 160 - 4 975 880 775 675 575 485 405 310 195 - 5 1050 960 865 770 680 585 500 425 340 235 6 1120 1035 950 860 770 685 595 515 445 360 7 1210 1130 1050 965 880 800 715 635 565 495 8 1295 1220 1140 1065 985 905 830 755 670 605 090M24-20 9 1395 1320 1250 1180 1100 1030 955 885 810 735 10 1460 1390 1325 1255 1190 1115 1045 975 905 - 840 11 Heating 1550 1485 1420 1355 1295 1225 1155 1090 1020 960 12 1615 1550 1490 1430 1370 1305 1240 1175 1110 1045 13 1710 1650 1595 1535 1475 1420 1355 1295 1235 1175 14 1785 1730 1675 1615 1560 1510 1450 1390 1330 1275 15 1890 1835 1780 1725 1675 1620 1570 1520 1460 1410 16 1970 1920 ' 1865 1815 1765 1715 1670 1620 1570 1520 17 2050 2000 1950 1905 1855 1810 1760 1720 1675 1625 18 Cooling 2170 2120 2070 2025 1980 1930 1880 1820 1765 1695 1 Constant Fan 845 730 625 520 420 330 240 135 - - 2 920 810 705 610 515 425 345 260 155 -- 3 1025 920 825 735 645 560 475 400 320 245 4 1115 1015 930 840 760 675 595 520 445 380 5 1235 1150 1060 980 900 825 750 675 600 525 6 1340 1260 1180 1100 1025 955 885 810 740 675 7 1440 1365 1290 1215 1140 1070 1005 940 875 805 8 1530 1460 1390 1320 1250 1185 1115 1055 995 930 110M21--20 9 1640 1575 1510 1440 1375 1310 1250 1190 1130 1075 10 1745 1685 1620 1555 1495 1430 1370 1315 1260 1205 11 1835 1780 1720 1665 1605 1550 1490 1435 1380 1330 12 Heating 1895 1840 1785 1730 1675 1615 1560 1505 1455 1400 13 1950 1895 1840 1785 1725 1670 1615 1565 1510 1460 14 2055 2005 1955 1900 1845 1790 1740 1690 1640 1590 15 2160 2110 2065 2015 1960 1910 1860 1815 1765 1720 16 Cooling 2260 2210 2165 2120 2070 2020 1975 1930 1885 1840 17 2355 2310 2265 2225 2180 2135 2090 2045 2005 1960 18 2520 2480 2435 2395 2350 2310 2255 2195 2135 2080 1 Constant Fan 840 725 615 506 400 310 215 135 - - 2 930 825 720 620 520 420 335 250 165 - 3 1015 915 815 725 630 530 440 360 280 205 4 1095 995 905 815 725 635 540 460 385 310 5 1185 1090 1005 915 835 750 665 580 500 430 6 1250 1160 1080 1000 915 840 755 675 595 525 7 1335 1255 1175 1100 1020 940 870 790 710 635 8 1435 1355 1280 1210 1140 1060 990 920 845 780 110M24--20 9 1510 1435 1360 1290 1225 1155 1085 1015 950 880 10 1600 1530 1455 1390 1325 1260 1190 1125 1060 995 11 1685 1615 1545 1480 1420 1360 1295 1230 1165 1110 12 1760 1695 1630 1565 1505 1450 1390 1330 1270 1210 13 1855 1795 1730 1670 1610 1560 1505 1445 1385 1330 14 1945 1885 1830 1770 1710 1655 1605 1555 1495 1445 15 Heating 2025 1970 1915 1855 1800 1750 1700 1650 1600 1550 16 2055 2000 1945 1890 1835 1785 1735 1685 1635 1585 17 2125 2070 2015 1965 1910 1860 1815 1765 1720 1670 18 Cooling 2220 2170 2115 2060 2005 1960 1905 1860 1810 1750 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 9 58SB0B/58SB1B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure On.w.c. 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1 Constant Fan ' 760 635 520 405 290 175 -- -- — — 2 815 700 590 485 370 270 155 -- — 3 905 795 685 590 490 380 290 185 — — 4 975 870 770 680 590 490 395 310 205 — 5 1025 920 825 740 655 560 460 375 290 195 6 1120 1025 935 845 770 690 600 505 420 350 7 1205 1120 1030 945 870 800 720 635 550 470 8 1285 1200 1120 1040 965 900 830 750 675 590 135M24-20 9 1380 1305 1225 1150 1075 1010 950 885 815 735 10 1450 1380 1305 1230 ' 1160 1095 1030 975 910 840 11 1555 1480 1415 1345 1275 1210 1150 1095 1045 985 12 1635 1565 1500 1435 1370 1310 1245 1190 1140 1090 13 1710 1645 1585 1525 1460 1400 1340 1285 1230 1185 14 ' 1785 1725 1665 1600 1545 1485 1425 1375 1320 1275 15 Heating ' 1870 1805 1750 1695 1640 1580 1525 1475 1420 1375 16 1940 ' 1885 1830 1780 1725 1675 1620 1570 1520 1475 17 2020 1965 1915 1865 1815 1765 1715 1665 1620 1580 18 Cooling 2125 2075 2025 1975 1925 1875 1825 1775 1705 1640 1 Constant Fan 765 645 520 395 290 185 -- — — 2 860 750 635 ' 520 410 315 220 145 -- — 3 915 810 705 600 485 385 300 210 135 — 4 1000 895 795 695 595 490 400 320 230 145 5 1075 975 880 790 695 595 500 420 335 260 6 1170 1075 985 900 815 730 635 545 470 390 7 1260 ' 1170 1090 1010 930 845 765 675 590 510 8 1340 1255 1180 1100 1025 950 870 795 710 625 155M24-20 9 1415 1340 1260 1190 1120 1045 970 895 815 745 10 1505 1430 1355 1290 1220 1150 1080 1010 945 870 11 1575 1500 1430 1365 1295 1230 1165 1100 1030 970 12 1660 1590 1520 1455 1395 1335 1275 1210 1140 1085 13 1735 1670 1605 1545 1485 1425 1365 1310 1250 1185 14 1825 1760 1700 1640 1585 1530 1475 1425 ' 1365 1310 15 1920 1860 1800 1740 1685 1630 1580 1530 1475 1420 16 Heating 2000 1945 1890 1825 1775 1725 1675 1625 1575 1525 17 2085 2035 1980 1925 1870 1825 1780 1740 1695 1650 18 Cooling 2205 2150 2095 2040 1985 1935 1885 1835 1775 1720 NOTE: 1. A filter is required for each return-air inlet.Airflow performance included 3/4-in.(19 mm)washable filter media such as contained in a factory-authorized accessory filter rack.See accessory list.To determine airflow performance without this filter,assume an additional 0.1 in.w.c.available external static pressure. 2. Adjust the blower airflow setting as necessary for the proper air temperature rise for each installation. 3. Airflows over 1800 CFM require bottom return,two-side return,or bottom and side return.A minimum filter size of 20"x 25"(508 x 635 mm)is required. 4. For upflow applications,air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return. 5. The--entry indicates unstable operating conditions. Airflow Settings Default Airflow Settings* Designated Airflow Settings Unit Size Heating Cooling Heating Constant Fan 045M14-12 8 18 (4-12) (1-7) 045M17--14 6 18 (4-12) (1-7) 070M14-12 15 18 (9-16) (1-7) 070M17-12 15 18 (11-17) (1-8) 070M17-16 12 18 (7-13) (1-4) 070M21-16 10 18 (6-14) (1-8) 090M17--14 12 18 (7-16) (1-9) 090M21--16 13 18 (8-16) (1-6) 090M21-20 11 17 (7-14) (1-9) 090M24-20 11 18 (7-16) (1-10) 110M21-20 12 16 (8-15) (1-9) 110M24--20 15 18 (9-17) (1-6) 135M24--20 15 18 (12-16) (1-7) 155M24-20 16 18 (13-17) (1-2) *. Setting#1 is the default setting for Constant Fan Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 10 58SBOB/58SB1B:Product Data TYPICAL WIRING SCHEMATIC FURNACE CONTROL BOARD ]-SEGMENTOaAY n SNFNPWGCONNECTON-SEN4%E ----FIELD 24-V WIRING �o �. MD PuwSunons BOARD NEPIACENENTOSEONLY ----FIELD 115-,208/230-,460-VWIRING I —FACTORY 24-V WIRING —FACTORY 115-VWIRING ° 8.8.8.rrnIroti \ II' — 4,...* NOTE 2 ' TnN '�� .tnc ° rwcNxrtxNN w c a a nw THERMOSTAT u FIVE WIRE 4 4 Q Q Y TERMINALS FIELD-SUPPLIED 24VA «3 r THREE-WIRE i I DISCONNECT BIVA _f HEATING-ONLY Is dr 1 a«<,, mowMeo, BLOWER DOOR SWITCH " , 20B/230-OR 2. TNT ■ir- 1 +tit = 1 4604 TIro7I _ x I is THREE [G71 N 7 T AK�y�64. 7._ 0 1 1 1 �; ., - PHASE :"4vE4c ��c o " xS f ff OnE)__ _C O•___1_-' ,,rK ._' C t S?g Loom. --� 1 srann LED uon lE0 K -i N 1 It--•-- 1�1 208/230-V t5 =GNB F1'GND R G - r- rlFa-- 1 --1 SINGLE �,NPraEE R, 115-VFIELD- AUXILIARY 0 __l 1 J(PHASE �� SUPPLIED J-BOX L�=� 1 1 1 rt--- r • ' V. DISCONNECT NOTE 1 ;I CONDENSING - y z z4v Two UNIT aaNE/,N 0 1111 1® o 0 000 ° E4C-1 r eNSI TERMINAL WIRE r Nww f t BLOCK .0, sSuuPPxLY 4;aN FURNACE NOTES:1. ConnectY-terminal in furnace as shown for proper dower operation. coaa,Eaa„a 2.Some thermostats require a"C"terminal connection as shown. 3.If any of The original wire,as supplied,must be replaced,use same lone or eaulalent wire. A190079 A210192 VENTING CONFIGURATIONS — I ® l� tic 0 I ,„;_..„: . _ w Ii liff----J'.„.:`-' 1 1� i� m.,,-------,,,,,.... , SEE NOTES:12,3,4,5,7.8,9,, _ i SEE NOTES:1,2,4,5,7,8,9 on tre page following on the page following g1�e urn These figures A03210 A03211 Application-Vent Elbow Up then Left Downflow Application-Vent Elbow Up Downflow t C... I 11 1 1, r_ f SEE NOTES:1,2,3,4,7,8y SEE NOTES:1,2,4,5,6,7,8,9 tlo 5e pages followi on the page following these figures ng gores A03207 A03209 Downflow Application-Vent Elbow Left then Up Upflow Application-Vent Elbow Right i r,,,,/ 1 o 11111114SEE NOTES:12,4,7,8,9 on the pegs following these figures SEE NOTES:1,2,4,5,7,8,9 A03213 A02068 Horizontal Left Application-Vent Elbow Left Horizontal Right Application-Vent Elbow Left Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 11 58SBOB/58SB1B:Product Data - It` o 'ja 11'; �;�+ a, I ��f .r 0 SEE NOTES:1,2,4,5,7,8,9 on the page following these figures A03219 Horizontal Right Application-Vent Elbow Left then Up SEE NOTES:1,2,4,7,8,9 on the page following these figures A03208 �� °lk Upflow Application-Vent Elbow Up e_ • I7 O Ir . ,if il SEE NOTES:1,2,4,5,7,8,9 on the page 0 III following these figures Horizontal Left Application-Vent Elbow Right then Up MIIIMMINISM Venting notes: A03214 1. For common vent,vent connector sizing and vent material:United States, latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA Lirli., , 54. i 2. Immediately increase to 5-in. (127 mm) vent connector outside furnace casing when 5-in.(127 mm)vent connector required,refer to Note 1. SEE NOTES:1,2,3,4,5,7,8,9 done fi figures. following 3. Side outlet vent for upflow and downflow installations must use Type B g vent immediately after exiting the furnace, except when Downflow Vent A03212 Guard is used in downflow position. Downflow Application-Vent Elbow Up then Right 4. Type B vent where required,refer to Note 1. 5. 4-in.(102 mm)single wall vent must be used inside furnace casing and the i Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit required in downflow installations II I with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. foeseSEE Ewing8 1Hgur7,,9 on the Page 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet A03218 metal screws,space approximately 180 apart. Horizontal Right Application-Vent Elbow Right 9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120 apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. r. .... ... ..,,, I ' r:„ I o SEE NOTES:1,2,4,5,7,9,9 on the page following these figures A03216 Horizontal Left Application-Vent Elbow Right .°.; t` e° SEE NOTES:1,2,4,5,7,8,9 on the page following these figures A03215 Horizontal Left Application-Vent Elbow Up Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 12 58SBOB/58SB1B:Product Data ACCESSORIES PART NO. DESCRIPTION 045M14-12 045M17-14 070M14-12 070M17-12 070M17--16 070M21-16 090M17-14 ACG1425NCB" External Filter Rack,14-1/2 x 25" X - X - - - - ACG1625NCF" External Filter Rack,16 x 25" - X - X X - X ACG2025NCJ" External Filter Rack,20 x 25" - - - - - X - 325531-402* Washable filter,3/4"x 16"x 25" X X X X X - X 325531-403" Washable filter,3/4"x 21"x 25" - - - - - X - KGADA0101ALL Coil Adapter Kits-No Offset X X X X X X X KGADA0201ALL Coil Adapter Kits-Single Offset X X X X X X X KGADA0301ALL Coil Adapter Kits-Double Offset X X X X X X X KGARP0301614 Return Air Base(Upflow Applications) X - X - - - 14-3/16"wide KGARP0301617 Return Air Base(Upflow Applications) - X - X X - X 17-1/2"wide KGARP0301621 Return Air Base(Upflow Applications) -- - X - 21"wide KGACA02014FC Chimney Adapter Kit,up to or equal to X X X X X X X 110K BTUh KGAFE0112UPH Flue Extension X X X X X X X KGAVE0101 DNH Vent Extension Kit X X X X X X X _ Combustible Floor Base(Not KGASB0201ALL required when evaporator coil case X X X X X X X is used for downflow) KGBVG0101 DFG Downflow Vent Guard(Not required X X X X X X X when vent is routed through cabinet) AGAGC8NPSO1B" Natural-to-Propane Conversion Kitt X X X X X X X AGAGC8PNS01B" Propane-to-Natural Conversion Kitt X X X X X X X AGATWNDTE01 B Twinning Kit FCT-ECM Motor - - - - - X - *. Purchased through Replacement Components t. Factory-authorized and field installed.Fuel conversion kits are CSA recognized. X=Accessory Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 13 58SBOB/58SB1B:Product Data ACCESSORIES (Continued) PART NO. DESCRIPTION 090M21-16 090M21-20 090M24-20 110M21--20 110M24-20 135M24-20 155M24-20 ACG2025NCJ` External Filter Rack X X X -20 x 25" - ACG2424NCL` External Filter Rack 24-1/2 x 24" - X X X X 325531-403` Washable filter X X - X 3/4"x21"x25" ' 325531 404` Washable filter - - X - X 3/4"x 24"x 25"` X X KGADA0101 ALL Coil Adapter Kits-No Offset X X X X X X X KGADA0201ALL Coil Adapter Kits-Single Offset X X X X X X X KGADA0301ALL Coil Adapter Kits-Double X X X X X X X Offset KGARP0301621 Return Air Base(Upflow X X Applications)21"wide X - KGARP0301 B24 Return Air Base(Upflow Applications)24-1/2 wide - X X X X KGACA02014FC Chimney Adapter Kit,up to X X X X X or equal to 110K BTUh Chimney Adapter Kit, KGACA02015FC greater than or equal to - - - - - X X 135K BTUh KGAFE0112UPH Flue Extension X X X X X X X KGAVE0101DNH Vent Extension Kit X X X X X X X Combustible Floor Base(Not KGAS80201ALL required when evaporator X X X X X coil case is used for down- flow) X X Downflow Vent Guard(Not KGBVG0101 DFG required when vent is routed X X X X X X X through cabinet) Natural-to-Propane AGAGC8NPS01B` Conversion Kitt X X X X X X X Propane-to-Natural AGAGC8PNSO1 B` Conversion Kitt X X X X X X X AGATWNDTE01B Twinning Kit FCT-ECM Motor X X X X X X X *. Purchased through Replacement Components t. Factory-authorized and field installed.Fuel conversion kits are CSA recognized. X=Accessory ORFICIES Gas Orifice Kit-#42(Nat Gas) LH32DB207 Gas Orifice Kit-#43(Nat Gas) LH32DB202 Gas Orifice Kit-#44(Nat Gas) LH32DB200 Gas Orifice Kit-#45(Nat Gas) LH32DB205 Gas Orifice Kit-#46(Nat Gas) LH32DB208 Gas Orifice Kit-#47(Nat Gas) LH32DB078 See Installation Instructions for model,altitude, Gas Orifice Kit-#48(Nat Gas) LH32DB076 and heat value usages. Gas Orifice Kit-#54(LP) LH32DB203 Gas Orifice Kit-#55(LP) LH32DB201 Gas Orifice Kit-#56(LP) LH32DB206 Gas Orifice Kit-1.25mm(LP) LH32DB209 Gas Orifice Kit-1.30mm(LP) LH32DB210 DESCRIPTION ACCESSORY HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL Carrier has a wide variety of thermostats for your system,please visit www.Carrier.com to see all thermostat and IAQ products. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 14 58SB0B/58SB1B:Product Data ACCESSORIES (Continued) DESCRIPTION ACCESSORY 14" 17" 21" 24" Carrier Carbon Monoxide Alarm(10 pack) COALMCCNRB02-A10 X X X X Carrier Infinity Air Purifier-16x25(407x635 mm) DGAPAXX1625 X X - - Carrier Infinity Air Purifier-20x25(508x635 mm) DGAPAXX2025 - - X X Carrier Infinity Air Purifier Repl.Filter-16x25(407x635 mm) GAPCCCAR1625-A05 X X - - Carrier Infinity Air Purifier Repl.Filter-20x25(508x635 mm) GAPCCCAR2025-A05 - - X X Cartridge Media Filter-16"(407 mm)(MERV 11) FILXXCAR0116 X X - - Cartridge Media Filter-16"(407 mm)(MERV 8) FILXXCAR0016 X X - - Cartridge Media Filter-20"(508 mm)(MERV 8) FILXXCAR0020 - - X - Cartridge Media Filter-20"(508 mm)(MERV11) FILXXCAR0120 - - X - Cartridge Media Filter-24"(610 mm)(MERV 8) FILXXCAR0024 - - - X Cartridge Media Filter-24"(610 mm)(MERV11) FILXXCAR0124 - - - X EZ Flex Cabinet Side or Bottom-16" EZXCAB--0016 X X - - EZ Flex Cabinet Side or Bottom-20" EZXCAB-0020 - - X X EZ Flex Replacement Filters 16"MERV 10 EXPXXFIL0016 X X - - EZ Flex Replacement Filters 16"MERV 13 EXPXXFIL0316 X X - - EZ Flex Replacement Filters 20"MERV 10 EXPXXFIL0020 - - X - EZ Flex Replacement Filters 20"MERV 13 EXPXXFIL0320 - - X - EZ Flex Replacement Filters 24"MERV 10 EXPXXFIL0024 - - - X EZ Flex Replacement Filters 24"MERV 13 EXPXXFIL0324 - - - X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 10) EXPXXUNV0016 X X - - EZ-Flex Filter with End Caps-16"(407 mm)(MERV 13) EXPXXUNV0316 X X - - EZ-Flex Filter with End Caps-20"(508 mm)(MERV 10) EXPXXUNV0020 - - X - EZ-Flex Filter with End Caps-20"(508 mm)(MERV 13) EXPXXUNV0320 - - X - EZ-Flex Filter with End Caps-24"(610 mm)(MERV 10) EXPXXUNV0024 - - - X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 13) EXPXXUNV0324 - - - X Media Filter Cabinet-20" FILCABXL0020 - - X - Media Filter Cabinet-24" FILCABXL0024 - - - X Media Filter Cabinet-16" FILCABXL0016 X X - - ©2022 Carrier.All rights reserved. Edition Date:08/22 Catalog No:58SBOB-01PD REV A Replaces:58SBOB-01PD Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 15 N, Whisper eteG�'" euitt-In Self Adjusting FV-1115VK2 VENTILATIONN Arno En] Specification Submittal Data /Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan,low sone and rated for continuous operation. ENERGY STAR°rated and certified by the Home Ventilating Institute(HVI).Evaluated by 6" duct the Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: •Enclosed brushless ECM smart motor technology rated for continuous operation •Adjustable ventilation rates at 110-130-150 CFM \� •Power rating of 120 volts and 60 Hz �,,; C 1�� y�0 g^ •UL and cUL listed for tub/shower enclosure when GFCI protected � I. s4 •Motor equipped with thermal cutoff fuse \ •Removable permanently lubricated plug-in motor 73/e". ,Iti' I�I� il Housing: i lam. . i •Environmentally friendly 26 gauge housing using Zinc-Aluminum-Magnesium(ZAM)coating �/ Ni/ 1 ;✓✓' •Integrated 6"diameter duct adapter •Built-in damper reduces back draft and helps with blower door testing •Built-in metal flangeprovides blockingforpenetrations through drywallto va^ 9 g as an Air io va Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing _ •Suitable for installation in ceilings insulated up to R60 1311.%4410, •Articulating and expandable installation bracket up to 24" Grille: /i © •Attractive design using Poly Pro material •Attaches directlyto housingwith torsion springs 13 �L� •Includes a motion sensor cap for use as a cover when the motion sensor � Plug'n PlayTM module has not been selected Warranty: •ECM Motor:6 Years from original purchase date •ALL Parts:3 Years from original purchase date Architectural Specifications: FV-1115VK2 Customizable ceiling mount ventilation fan, ENERGY STAR° rated with built-in speed selector.Select from 110/130/150 CFM with<0.3 sone as certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with 112/130/151 CFM and no more than 0.3/0.4/0.7 sones at 0.25 w.g.and 105/124/132 CFM at 0.375 w.g.Power Consumption shall be no greater than Performance Curve 6"duct 6.9/9.2/12.9 watts at 0.1 w.g.and 12.8/16.5/22.0 watts at 0.25 w.g.and 17.9/22.1/24.4 watts at 0.375 w.g.ENERGY STAR°rated with efficiency of no less than 16.0/14.2/11.7 CFM/watt at 0.1 w.g.and 8.7/7.9/6.8 CFM/watt at 0.25 w.g.and 5.8/5.6/5.4 CFM/watt at 0.375 w.g.The motor shall be enclosed with brushless ECM motor engineered to run continuously.ECM motor speed shall automatically increase when the fan senses static —1 FM pressure to maintain selected CFM.Power rating shall be 120v/60Hz.Duct diameter shall i o be no less than 6".Plug'N Play'"modules provide up to three additional features.Select i °.,^ _- oon from Multi-Speed with Time Delay,Condensation Sensor,and SmartAction Motion Sensor. l"" ___—_ r__i� -1 ter" Fan shall be RoHS Compliant and UL and cUL listed for tub/shower enclosure when GFCI al I -00`"' protected.Also suitable for installation in ceilings insulated up to R60..Fan can be used a a.i ;-I-- I i- -- ----- M to comply with ASHRAE 62.2,LEED,ENERGY STAR°IAP,EarthCraft,California Title-24 I l ' t I i I f osa - ---....-._i Y - ae a,�,and WA Ventilation Code. -- ) l 3 ; M"a�, ( I , n �PC'T F40is. ECM Motor Technology: 1 I I 1 When fan senses static pressure,its speed is automatically increased to - 00 00 F'i, ensure that the desired CFM is not compromised,which allows the fan to Mitaw(CFMI �" -HNo0-° perform as rated. Industry research indc tes static Prawn in tYWcal insWNationa ranges from 020•to 0.375' Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/venffans Ceiling Radiation Damper:whisperGreen Select"is UL listed for use with the Panasonic Ceiling Radiation Damper(Model#:PC-RDOSCS,sold separately). co))Whi FAr ro-"\ eeeet- BuiR-InSelf_,Adjusting FV-1115VK2 VENTILATION N ArAowCapability Plug 'N PlayTM Modules Plug'N Play"modules provide up to three additional features.Select from Multi-Speed with Time Delay,Motion Sensor,and Condensation Sensor. FV VS15VK1: Multi-Speed with Time Delay Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0,50-120 CFM,in 10 CFM increments),then elevates to a maximum level of operation (110-130-150 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated.A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVKI: Motion Sensor 1 .., - a Automatically activates when someone enters the room.Once the settings have been applied,the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects relative humidity and temperature to anticipate dew point,automatically turning the fan on to control humidity.Built-in Relative Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensation sensor is used in conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates a 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select"':FV-1115VK2 Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 Air Volume(CFM) 150 151 132 130 130 124 110 112 105 Noise(sones) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 6.9 12.8 17.9 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 16.0 8.7 5.8 Speed(RPM) 684 916 1084 645 900 1080 625 894 1083 Current(amps) 0.14 0.22 0.24 0.10 0.17 0.22 0.08 0.13 0.18 MAX.Current(amps) 0.24 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes Industry research indicates static pressure in typical installations ranges from 0.20"to 0.375" Fan Specifications FV- 115VK2+FV-VS15VK1 Multi Spee. Plug'N PI "'module) Static Pressure in inches w.g. 0.1 0.25)373 0.1 0.25 1375 0.1 0.25 0.375 0.1 0.25 i 375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 o.375 0.1 0.25 1.373 0.1 0.25 .377 0.1 0.25).377 Air Volume(CFM) 150 151 132 130 130 124 120 120 122 110 112 105 100 100 97 90 91 90 80 81 80 70 71 70 60 60 60 50 50 50 Noise(sons) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - <0.3 0.3 - <0.3 0.2 - <0.3 0.3 - <0.3 0.3 - <0.3 0.4 - <0.3 0.4 - <0.3 0.5 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 7.7 14.0 20.5 6.9 12.8 17.9 5.5 11.0 16.0 4.7 9.7 15.0 4.2 9.0 13.9 3.7 8.1 12.2 3.3 7.2 11.2 3.0 6.4 10.2 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 15.7 8.6 6.0 16.0 8.7 5.8 18.2 9.1 6.0 19.1 9.3 6.0 19.0 9.0 5.7 19.2 8.8 5.8 18.2 8.3 5.3 17.3 8.1 5.1 Speed(RPM) 684 916 1084 645 900 1080 633 895 10861625 894 1083 615 8981093 602 900 1099 608 912 1104 591 9141109 608 913 1117 609 910 1116 Current(amps) 0.14 0.22 0.24 0.10 0.17 0.22 0.09 0.15 0.2110.08 0.13 0.18 0.07 0.12 0.16 0.06 0.10 0.15 0.05 0.10 0.14 0.05 0.09 0.13 0.04 0.08 0.12 0.04 0.07 0.11 MAX.Current(amps) 0.33 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes - "Industry research indicates static pressure in typical installations ranges from 0.20"to 0.375" Panasonic Life Solutions Company of America -, Most Efficient TwoIAQ Division 7 ZO20 Two Riverfront Plaza Newark,NJ 07102 ,w,,,,,.„ „_e,,. us.panasonic.com/ventfans Panasonic NnVv C®65 IAQ19073SS r3