OFFICE COPY Oregàn RECEIVED Heating&Air Conditioning OCT 0 4 2023 CITY OF TIGARD Tigard Vision Center BUILDING DIVISION 9169 SW Burnham St Tigard, OR 97223 Scope of Work Oregon Heating and Air Conditioning will perform the following scope of work: 1. Replace attic gas furnace, like-for-like. 2. Replace ground-level AC, like-for-like. s 0 S . 4 • +10 i # a * �r ' ,. of oe f � _ F.. N14. littilio ' � 7 .s `,, �� VALIDITY OF PERMIT CITY OF TIGARD REVIEW D FOR CODE COMPLIANCE M 1 THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION Approved: ] DOCUMENTS AND OTHER OTC: [ ] DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM Permit#: m P,G �fl�1' Q -7 4,5 OHAC Address:REQUIRING THE CORRECTION j C,9 �,r�h i.,,,� CCB # 137653 OF ERRORS. OSSC 105.4 Suite#: LI Date: Jo .l z 1-� PHONE NUMBER OPERATIONS CONTRACTOR LICENSE 503-691-9699 6950 SW 111"'Ave Oregon CCB 137653 V Beaverton,OR 97008 WA OREGOHC85102 RECEIVED OCT 0 4 2023 CITY OF TIGARD BUILDING DIVISION EXISTING FURNACE SPECS TRANE® 0 o n o rizintal wo tag as-Fired Furna e XL 80 TDD040, 060, 080, 100, 120, 140R Fan Assisted Combustion System fsf}jEfffffii iliiHiIHhtI _ " :hhhhhhhhhhhifl 701"` "'xceo PUB. NO. 22-1672-03-998 (EN) num. General Features NATURAL GAS MODELS AIR DELIVERY Central heating furnace designs are The multispeed,direct drive blower certified by the American Gas motor,with sufficient airflow range for Association for both natural and L.P.gas. most heating and cooling requirements, Limit setting and rating data were will switch from heating to cooling established and approved under speeds on demand from room standard rating conditions using thermostat.The blower door safety switch American National Standards Institute will prevent or terminate furnace standards. operation when the blower door is SAFE OPERATION removed. The Integrated System Control has solid STYLING state devices,which continuously Heavy gauge steel and"wrap-around" monitor for presence of flame,when the cabinet construction is used in the system is in the heating mode of cabinet with baked-on enamel finish for operation.Dual solenoid combination strength and beauty.The heat exchanger gas valve and regulator provide extra section of the cabinet is completely lined safety. with foil faced fiberglass insulation.This QUICK HEATING results in quiet and efficient operation Durable,cycle tested,heavy gauge due to the excellent acoustical and aluminized steel heat exchanger quickly insulating qualities of fiberglass. transfers heat to provide warm FEATURES AND GENERAL conditioned air to the structure.Low OPERATION energy power vent blower,to increase The XL 80 High Efficiency Gas Furnaces efficiency and provide a positive employ a Hot Surface Ignition system, discharge of gas fumes to the outside, which eliminates the waste of a constant allows common venting with hot water burning pilot.The integrated system heater. control lights the main burners upon a BURNERS demand for heat from the room Multi-port in-shot burners will give years thermostat.Complete front service of quiet and efficient service.All models access. can be converted to L.P.gas without a.Low energy power venter. changing burners. b.Vent proving differential switch. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers,gas valve,flame control and includes self diagnostics for ease of service.Also contains connection points for E.A.C./humidifier. ©American Standard Inc.1998 2 PUB.NO.22-1672-03-998(EN) TRAWl Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 6 TDD040R924 TDD060R936 TDD080R936 TDD 100R945 TDD100R948 TDD 100R960 TDD 120R960 TDD 140R960 Performance Data 7 Electrical Data 8 Field Wiring 9 Dimensions 11 PUB.NO.22-1672-03-998(EN) 3 TRANS® Features and Benefits XL 80 STANDARD EQUIPMENT • Power supply 115/1/60 • Adjustable fan off times • 2-stage gas valve • Common vent capability • 2-speed inducer • Cleanable high velocity filters • 2 heating blower speeds • Blower door safety switch • Hot surface igniter • Left/right gas connection • Integrated system control • Heavy gauge reinforced wrap-around • Attractive color accents steel cabinet • Heavy gauge aluminized steel heat • Horizontal left or right without exchanger conversion required • Multi-port In-shot burners • Optional L.P.conversion kit • Complete front service access • Non-prorated 20-year heat exchanger limited warranty • Slide out blower assembly • Direct drive,4-speed motors 4 PUB.NO.22-1672-03-998(EN) Aft TRANS® Features and Benefits OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling BAYSTAT241 [ ] Thermostat, Mechanical Heating Only With Fan Switch BAYSTAT303[ ] Thermostat, Heating/Cooling Single Stage(Mounts Horizontally) AY28X092[ ] Thermostat, Heating/Cooling Single Stage(Mounts Vertically) BAYSTAT305[ ] Thermostat, Electronic Programmable 2-Stage Heating/1-Stage Cooling BAYSTAT302B[ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling BAYSTAT300[ ] Propane Conversion Kit BAYLPKT210A[ ] Electronic Air Filter,"Perfect Fit"Super Efficiency(14-1/2"Wide Gas Furnace) TFE145A9FRO[ ] Electronic Air Filter,"Perfect Fit"Super Efficiency(17-1/2"Wide Gas Furnace) TFE175A9FRO[ ] Electronic Air Filter,"Perfect Fit"Super Efficiency(21"Wide Gas Furnace) TFE210A9FRO[ ] Electronic Air Filter,"Perfect Fit"Super Efficiency(24-1/2"Wide Gas Furnace) TFE245A9FRO[ ] Electronic Air Filter,"Perfect Fit"High Efficiency(14-1/2"Wide Gas Furnace) TFM145A9FRO[ ] Electronic Air Filter,"Perfect Fit"High Efficiency(17-1/2"Wide Gas Furnace) TFM175A9FR0[ ] Electronic Air Filter, `Perfect Fit"High Efficiency(21"Wide Gas Furnace) TFM210A9FRO[ ] Electronic Air Filter,`Perfect Fit"High Efficiency(24-1/2"Wide Gas Furnace) TFM245A9FRO[ ] Electronic Air Filter,"Perfect Fit"Standard Efficiency(14-1/2"Wide Gas Furnace) TFP145A9FRO[ ] Electronic Air Filter,"Perfect Fit"Standard Efficiency(17-1/2"Wide Gas Furnace) TFP175A9FR0[ ] Electronic Air Filter,"Perfect Fit"Standard Efficiency(21"Wide Gas Furnace) TFP210A9FRO[ ] Electronic Air Filter,"Perfect Fit"Standard Efficiency(24-1/2"Wide Gas Furnace) TFP245A9FRO[ ] Coil Enclosure(14-1/2"Wide Cabinets) BAYCLE1400[ ] Coil Enclosure(17-1/2"Wide Cabinets) BAYCLE1700[ ] Coil Enclosure(21"Wide Cabinets) BAYCLE2100[ ] Coil Enclosure(24-1/2"Wide Cabinets) BAYCLE2400[ I Downflow Subbase BAYBASE205[ ] High Altitude Switch BAYHALT239[ ] PUB.NO.22-1672-03-998(EN) 5 AM TRAIVE® General Data TDD-R PRODUCT SPECIFICATIONS® MODEL TDD040R924 TDD060R936 TDD080R936 TDD100R945 TYPE Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition RATINGS® 1st Stage Input BTUH 26,000 39,000 52,000 65,000 1st Stage Output BTUHO 20,800 31,200 41,600 52,000 2nd Stage Input BTUH 40,000 60,000 80,000 100,000 2nd Stage Output BTUH® 31,000 47,000 64,000 79,000 AFUE 80.6 80.3 80.6 80.3 Temp.Rise(Min.-Max.)°F. 30-60 30-60 35-65 40-70 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter-Width(In.) 10 x 6 10 x 7 10 x 7 10 x 8 No.Used 1 1 1 1 Speeds(No.) 4 4 4 4 CFM vs.in.w.g. See Fan Perf.Table See Fan Perf.Table See Fan Perf.Table See Fan Perf.Table Motor HP 1/5 1/3 1/3 1/3 R.P.M. 1075 1075 1075 1075 Volts/Ph/Hz 115/1160 115/1/60 115/1/60 115/1/60 FILTER-Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No:Size-Thk.) 2-14x20-1 in. 2-14x20-1 in. 2-14x20-1 in. 2-16x20-1 in. VENT COLLAR-Size(In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type-Fired Alum.Steel Alum.Steel Alum.Steel Alum.Steel -Unfired Gauge(Fired) 20 20 20 20 ORIFICES-Main Nat.Gas.Qty.-Drill Size 2-45 3-45 4-45 5-45 L.P.Gas Qty.-Drill Size 2-56 3-56 4-56 5-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS-Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot Number 2 3 4 5 POWER CONN.-V/PhfHz© 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity(In Amps) 5.2 8.5 8.5 9.1 Max.Overcurrent Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(IN.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated(In.) 41%x 16%x 30% 415/s 16%x 30% 415/0 19%x 30% 41%x 19%x 30% WEIGHT Shipping(Lbs.)/Net(Lbs.) 119/109 129/119 146/135 156/145 MODEL TDD100R948 TDD100R960 TDD120R960 TDD140R960 TYPE Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition RATINGS® 1st Stage Input BTUH 65,000 65,000 78,000 91,000 1st Stage Output BTUH® 52,000 52,000 62,000 74,000 2nd Stage Input BTUH 100,000 100,000 120,000 140,000 2nd Stage Output BTUH® 80,000 79,000 94,000 112,000 AFUE 80.1 80.2 80.3 80.8 Temp.Rise(Min.-Max.)°F. 35-65 35-65 35-65 45-75 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter-Width(In.) 10 x 8 11 x 10 11 x 10 11 x 10 No.Used 1 1 1 1 Speeds(No.) 4 4 4 4 CFM vs.in.w.g. See Fan PerTable See Fan Perf.Table See Fan Perf.Table See Fan Perf.Table Motor HP 1/2 3/4 3/4 3/4 R.P.M. 1075 1075 1075 1075 VoltslPh/HZ 115/1/60 115/1/60 115/1/60 115/1/60 FILTER-Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No:Size-Thk.) 2-16x20-1 in. 2-16x20-1 in. 2-16x20-1 in. 2-16x20-1 in. VENT COLLAR-Size(In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type-Fired Alum.Steel Alum.Steel Alum.Steel Alum.Steel -Unfired Gauge(Fired) 20 20 20 20 ORIFICES-Main Nat.Gas.Qty.-Drill Size 5-45 5-45 6-45 7-45 L.P.Gas Qty.-Drill Size 5-56 5-56 6-56 7-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS-Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot Number 5 5 6 7 POWER CONN.-V/Ph/Hz© 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity(In Amps) 14.2 12.8 12.8 13.1 Max.Overcurrent Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(IN.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated(In.) 41%x 23 x 30% 41%x 23 x 30% 41%x 26%x 30% 41%x 26%x 30% WEIGHT Shipping(Lbs.)/Net(Lbs.) 166/154 167/155 189/176 197/184 Ti)Central Furnace heating designs are certified by the American Gas Association Inc.Laboratories. ® Based on U.S.government standard tests. ®Ratings shown are for elevations up to 2000 feel.For elevations above 2000 feet:Ratings should be reduced at the rate ®The above wiring specifications are in accordance with National Electrical Code;however,installations must comply of 4%for each 1000 feet above sea level. with local codes. 6 PUB.NO.22-1672-03-998(EN) • • TRINE® Performance Data TDD-R FURNACE AIRFLOW(CFM)VS.STATIC PRESSURE(ins.w.g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 4- HIGH-Black 1070 1033 1000 960 920 860 810 740 - TDD040R924C 3- MED:HIGH-Blue 870 850 823 790 753 813 667 613 490 2- MED.-LOW-Yellow 740 720 690 663 627 588 547 483 - 1 - LOW-Red 633 600 577 543 507 463 420 360 - 4- HIGH-Black - 1429 1376 1318 1282 1188 1112 1029 - TDD060R936C 3- MED.-HIGH-Blue 1302 1276 1229 1188 1141 1088 1024 953 - 2- MED.-LOW-Yellow 1115 1100 1070 1035 1000 965 918 859 - 1 - LOW-Red 956 947 918 888 859 824 788 741 682 4- HIGH-Black 1523 1496 1463 1420 1369 1310 1243 1172 1100 TDD080R936C 3- MED:HIGH-Blue 1317 1307 1261 1260 1223 1175 1122 1060 1000 2- MED:LOW-Yellow 1123 1119 1106 1082 1056 1016 976 930 880 1 - LOW-Red 942 943 931 920 898 818 833 795 760 4- HIGH-Black 1767 1731 1669 1615 1546 1469 1392 1300 1146 TDD100R945C 3- MED:HIGH-Blue 1382 1354 1323 1292 1254 1207 1177 1108 1038 2- MED.-LOW-Yellow 1130 1138 1115 1085 1054 1015 977 938 877 1 - LOW-Red 840 831 815 792 762 731 700 '654 - 4- HIGH-Black 1965 1915 1865 1805 1740 1670 1587 1500 1370 TDD100R948C 3- MED.-HIGH-Blue 1645 1627 1605 1575 1535 1482 1421 1330 1220 2- MED:LOW-Yellow 1407 1398 1387 1375 1347 1318 1275 1190 1095 1 - LOW-Red 1202 1208 1205 1195 1166 1140 1105 1045 970 4- HIGH-Black 2165 2113 2060 1995 1929 1842 1755 1674 1593 TDD100R960C 3- MED:HIGH-Blue 1962 1927 1891 1839 1786 1724 1662 1581 1500 2- MED:LOW-Yellow 1705 1688 1671 1671 1600 1547 1492 1435 1377 1 - LOW-Red 1492 1467 1442 1442 1385 1346 1307 1243 1179 4- HIGH-Black 2241 2202 2163 2106 2049 1979 1908 1804 1700 TDD120R960C 3- MED:HIGH-Blue 1981 1962 1942 1904 1866 1805 1743 1680 1617 2- MED.-LOW-Yellow 1721 1705 1688 1671 1653 1611 1569 1515 1461 1 - LOW-Red 1476 1466 1456 1440 1423 1392 1361 1302 1243 4- HIGH-Black 2377 2321 2265 2199 2133 2050 1967 1877 1786 TDD140R960C 3- MED.-HIGH-Blue 2115 2081 2046 1992 1938 1872 1805 1727 1649 2- MED.-LOW-Yellow 1806 1793 1779 1738 1696 1655 1614 1556 1497 1 - LOW-Red 1527 1507 1486 1473 1459 1422 1384 1329 1273 From Dwg.21 D330727 Rev.9 CFM VS.TEMPERATURE RISE CFM (CUBIC FEET PER MINUTE) MODEL 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 TDD040R924C 59 49 42 37 33 TDD060R936C 56 49 44 40 37 34 32 TDD080R936C 59 54 49 46 42 TDD100R945C 62 57 53 49 46 44 41 TDD100R948C 62 57 53 49 46 44 41 39 37 TDD100R96OC 62 57 53 49 46 44 41 39 37 35 34 32 31 TDD120R960C 59 56 52 49 47 44 42 40 TDD140R960C 69 65 61 58 55 52 49 47 45 From Dwg.21C330671 Sh.2 Rev.5 PUB.NO.22-1672-03-998(EN) 7 rRavER Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES TDD040,060,080,100,120,140R LEGEND III VOLT NO HZ.TPM.POWER SUPPLY —24 Y. PER LOCAL CODES _..L1iE Y FACTORY WIRING 1.TEMP.ACTUATED SWITCH I I r j_ ---24 Y, FIELD WIRING N-.1 H i J =CND -�L IRE Y �PRESS.ACTUATED SWITCH � ' .i� A. �EARTN GROUND r r — l — 614 FUSIBLE l INK �.._ iINTEGRATED (tik TABL[A i #1d _FURNACE CONTROL 6N0 CHASSIS GROUND TERMINAL SEE Ow _ m r-____-- JUNCTION e% ■cool Liii WIRE NUT OR CONNECTOR '•f'FUSE 1.0. ._` •A• .■AM',FAN 1--CDtL ANUAL RESET B Mlq, ;= �• Ill NEAT LO A. —CAPAC ITCA SNITCH 44 nD till NEAT HI TO aN 1 T�°vTRANSFORMER TERMINA.BOMO L ME I.kLJ OFFCrlij CONNECTOR E" ■ENFR OF SWITCH 5ETT1NS 1 Rica ''Um I SEE COOT I tOFAN OFF I •CpLDR OF E t NOTE 3 —NK/3 ■HJN DELAY,51CONWi �✓ BLACK WIRE WITH SWI OR e•• Stilt BLUE MARKER I �HSgW1 OFpF�BµO o `//--L NRI SKIS I6N OELAYNSFAN O F 1 OLOR OF YAWNER ISECUN05 I BE BLACK OR ORANGE YL YELLOW 14 f, o VENT eN,c INDNI ONz OFF TINE I SR BROWN RD NHT E PAR P�URYLE y7p ON OFF 60 <55 'Al AO/6 IRO LO OFF ON NXI•• ON ON 110 NNK IND N BIT OFF INS I GV Gas Valve F — PSI Pres.Switch Input,First Stage ••FACTORY SET I CF Fan Capacitor PS2 Pres.Switch Input,Second Stage NH VW'S ION N I GND Ground HLI High Limit Input L Line HLO High Limit Output LVTB Low Voltage Terminal Board FP Flame Sensor Probe Wit LINE N MTR Motor MVH Gas Valve High,Second Stage WN/N VIP N N Neutral MVL Gas Valve Low,First Stage TCO High Temperature Limit Switch MV Gas Valve,Common NH tw N I IMPORTANT: INTEGRATED FURNACE CONTROL TNS Transformer TR 24V AC Trans.Common Side F I REPLACEMENT MUST WE AUTHORIZED HI Hi Fire,Second Stage TH 24V AC Trans.Hot Side NEC R I D.E.M.PART ONLY LO Low Fire,First Stage ** Thermally Protected Internally NUN N B/C Common .-� I PRESSURE SW. SENSOR PS,FL AIJE 1 1ST.STAGE °1-0 /\WARNING ® CAUTION AL 1 I NAEARDDus VOLTAGE. USE COPPER COROUCTORs aNLYI TC 0II J L YL O 5 • • rt.ntnte.. —1L rrrram���..�}--�-- H rN YL/N ID O'-TL/, DISCONNECT ALL ELECTRICAL POWER uNIT TERMINALS ARE NOT OESIOHEO INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF WECORE SERVICING. CONDUCTORS.T FP YAWWWTrN NAt Y rLW FAILURE TO DISCONNECT POWER FAILURE TO GO SO MAY CAUSE GND NVH "11— 4 SE FORE SERV IL lNe CAN CAUSE D CU DAMAGE TO TA(SIPYENT. `- I PRE56.SW i SEVERE PERSONAL INJURY OR DEATH, 6N0 2N0.StAOF GAS VALVE ® f__ N: 3 I OWMI[ i NYCOY o_, I enz TABLE A I YVL 'EA 4 I LO 1 SPEED TAPS FOR I.D.FAN MOTOR TR ------------ °— T" wI r A 6 a I MODELS PARK HEAT LO HEAT HI I-------1 1 0 e1m dLL "A" H "C" 1 r �- TDD040R924C4 BL RD YL IIIIII TO TIE RMOSTAT I FUANACE i TDD060R936C4 BL RD YL SEE NOTES 2,4,AND 5 Tr/INNING CONNECTOR NOTES: TDD080R936C4 YL RD BL 1.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED,IT MUST BE REPLACED TDD100R945C4 YL RD BL WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. 2.THERMOSTAT HEAT ANTICIPATOR SETTING:FIRST STAGE.38 AMPS,SECOND STAGE.13 AMPS IF SETTING IS TDD100R948C4 YL RD BL NOT FIXED ON THERMOSTAT.FOR SINGLE STAGE HEATING THERMOSTAT SET AT.51 AMPS. 3.THESE LEADS PROVIDE 120V POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER, TDD100R96005 BL RD YL MAX.LOAD 1.0 AMPS EACH. 4.JUMPER W1 AND W2 FOR SINGLE STAGE HEATING THERMOSTAT,SECOND STAGE WILL BE ENERGIZED 10 TDD120R960C5 YL RD BL MINUTES AFTER A CALL FOR HEAT. , 5.FOR PROPER OPERATION OF COOLING FAN SPEED,"Y"TERMINAL MUST BE CONNECTED TO ROOM TDD140R960C5 YL RD BL THERMOSTAT. (1)RED=LOW IMPORTANT:INTEGRATED CONTROL IS POLARITY SENSITIVE.HOT LEG OF 120V POWER SUPPLY MUST BE (2)YELLOW=MED.LOW CONNECTED TO THE BLACK POWER LEAD AS INDICATED ON WIRING DIAGRAM. (3)BLUE=MED.HIGH (4)BLACK=HIGH From Dwg.21 D340923 P03 8 PUB.NO.22-1672-03-998(EN) TISANE* Field Wiring FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) NOTES: _____�-.._ 1.BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE(S). I OROUND INTER r COMPONENT WIRING SCREW 2.LOW VOLTAGE(24 V.WIRING)TO BE NO.18 A.W.G.MIN. ---0„.--B FURNACE 2�v...... Fqq^�Tony 3.GROUNDING OF EQUIPMENT MUST COMPLY WITH q JUNCTION -----LINE v.J WIRING LOCAL CODES. I I 4.SET THERMOSTAT HEAT I rJ I BOX 1 24 V. Ewa LH BR n i I LINE V.24 ANTICIPATOR PER UNIT WIRING n I wv DIAGRAM. 5.THESE LEADS PROVIDE 115 V. ��"`"s�`eQ;1 I r—J �/— FURNACE POWER FOR CONNECTION OF E LW WA ELECTRONIC AIR CLEANER AND L EV3 HUMIDIFIER MAX.LOAD 1.0 AMPS wN —1 EACH. HUM SEE HAT 6.THIS WIRING IS ONLY FOR NOTE 92 zSSTAGE INGLE STAGENC THERMOSTATS REQUIRING r— -1 I COOLING THERMOSTAT CONNECTION TO TRANSFORMER EAC SEE I COMMON TERMINAL. NOTE 5 { •--� WITH FAN SWITCH INTEGRATED TERM INALS 7.THE"Y"TERMINAL FROM THE FURNACE CONTROL I -�" -THERMOSTATMUSTBEWIREDTO THERMOSTAT TERMINAL Y WI'ri2 H ©Q THE"Y"TERMINAL OF THE FURNACE CONTROL FOR PROPERPOWER I Q Q IN ES I SEE NOTE 6 BLOWER OPERATION DURING SU r 1 COOLING. I I J I MOW g 1•11111111ML 1 LOW VOLTAGE AIR CONDITIONING I '� OUTDOOR SECTION WITHOUT TRANSFORMER I SEE NOTE 7 From Dwg.21 B330203 Rev.0 FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) NOTES: _ 1.BE SURE POWER AGREES WITH EQUIPMENT INTER•COMPONENT WIRING NAMEPLATE(S). 2.LOW VOLTAGE(24 V.WIRING)TO BE NO.18 A.W.G.MIN. 1 (WOUND I Z`'v. FA roar 3.GROUNDING OF EQUIPMENT MUST COMPLY WITH SCREW ' -----LtNE v. wI tnG LOCAL CODES. FURNACE '--24 V. 4.SET THERMOSTAT HEAT ANTICIPATOR PER UNIT ,I I JUNCTION LINE v� ' }rPG WIRING DIAGRAM. I rJ i BOX S.THESE LEADS PROVIDE 115V. LR I- 4ri /- FURNACE 44 POWER FOR CONNECTION OF .,,,,,....a., win II"/ ELECTRONIC AIR CLEANER AND ..++ r--+ I I HUMIDIFIER MAX.LOAD 1.0 AMPS "C"00111" L IVH EACH. a ir3i 6.W1 AND W2 MUST BE JUMPERED w., r_� I TOGETHER FOR PROPER HUM SEE OPERATION,SECOND STAGE NOTE 5 " ' L SINGLE STAG HEATING WILL BEGIN 10 MINUTES r RN? HEATING/C D pL I N G AFTER FIRST STAGE. SAC SEE 1 wN I rJ I THERMOSTAT 7.THE"Y'TERMINAL FROM THE NOTE 5 L BN Lp WITH FAN SWITCH THERMOSTAT MUST BE WIRED TO INTEGRATED TERMINALS THE"Y"TERMINAL OF THE i_""` THERMOSTAT E CONTROL - - FURNACE CONTROL FOR PROPER THERMOSTAT TERMINAL R G I 2 w v BLOWER OPERATION DURING �� COOLING. 6�PP LY '� O O MG SEE NO?E / I '-FIELD WOOED JUMPER(MOTE 61 LOW VOLTAGE I -r AIR CONDITIONING WITHOQUT TRANSFORMER I __ -- From Dwg.218330204 Rev.0 PUB.NO.22-1672-03-998(EN) 9 aM TRINE® PIY Field Wiring FIELD WIRING DIAGRAM FOR 2 STAGE HEATING _____ _ __ NOTES: 1.BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE(S). aRouNO 2.LOW VOLTAGE(24 V.WIRING)TO BE NO.18 SCREW FURNACE A.W.G.MIN. I� Be �J U N C T I O N 3.GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. r--I = BOX 4.SET THERMOSTAT HEAT ANTICIPATOR PER UNIT Lp BK 1 I10 ��( WIRING DIAGRAM. FURNACE 5.THESE LEADS PROVIDE 115 V.POWER FOR T0,;....;GO CONNECTION OF ELECTRONIC AIR CLEANER rJ ' ....... LN WH I AND HUMIDIFIER MAX.LOAD 1.0 AMPS EACH. RK/3 I 6.THIS WIRING IS ONLY FOR THERMOSTATS J t REQUIRING CONNECTION TO TRANSFORMER HURH I. NOMMESEE {e r COMMON TERMINAL. e1 2 STAGE HEATING rr'--, THERMOSTAT EA0 SEE L BK I WITH FAN SWITCH NOTE 5 C INTEGRATED TERMINALS --- FURNACE CONTROL ®®©U B THERMOSTAT TERM MIN AL 0 '2' R =0 En f-SEE NOTE 6 I MI 1 INTER d"OYVUNENI WIR INU -------.------ { - F CRY ---LINE V. WIRp�INGt + L 12INF V. w� l 6 1 _____ _____I From Dwg.216330205 Rev.1 FIELD WIRING DIAGRAM FOR SINGLE STAGE HI!EATING AGR OUNR I INTER-COMPONENT WIRING CREW—BK"_FURNACE �24 Y.'II BK JUNCTION }FACTORY —LINE V.J WIRING (�`J BOX I 24 V. FE O I M BK I Ini LINE VJWIR L.IN6 re 9001,M '4 .-....1Lxr.COMM I f L YM I RK/! FURNACE I WH rJ NOTE55E {BK I Big I SINGLE STAGE HEATING INN I—'� I I THERMOSTATEAC _ NOTE55E BY 1 In I WITH FAN SWITCH TERM INALS INTEGRATED NOTES: THERMOSTAT TERMINAL I FURNACE CONTROL ©©E1� _1.BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE(S). I 7, 000 ® 2.LOW VOLTAGE(24 V.WIRING)TO BE NO.18 A.W.G.MIN. 3.GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL J I CODES. III / 1 4.SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 1 SEE NOTE 6 5.THESE LEADS PROVIDE 115 V.POWER FOR CONNECTION OF _._ - ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX.LOAD 1.0 I L„_e„__, ___.,_ AMPS EACH. 6.WHEN A SINGLE STAGE HEATING THERMOSTAT WITHOUT FAN FIELD ADDED JUMPER SWITCH IS USED,NO WIRING ON"G"TERMINAL IS USED. I :NOTE 71 7.W1 AND W2 MUST BE JUMPERED TOGETHER FOR PROPER —.— OPERATION,SECOND STAGE HEAT WILL BEGIN 10 MINUTES AFTER FIRST STAGE. __ ___I From Dwg.21B330206 Rev.0 10 PUB.NO.22-1672-03-998(EN) MANE. Dimensions TDD-R OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) 4.00 DIAMETER 1—5/8' FLUE OPENING 1i SIDE PANEL CUTOUT tC INALEET r�rwel HORIZONTAL VENTING THROUGH CABINET B L5/8 �4 16„ 7/8 DIA. K.O. 2 I/8" 19-5/8" ELECTRICAL CONNECTION 7/8" DIA. HOLES (AL TERN ATE I 5" ELECTR ICAL CONNECTION r 1/2"4.00 DIAMETER 24-1/2"4-1 —11111 FLUE CONNECTOR 'c r_ I 11/2 DIA. K.O. 2-1/8" GAS CONNECTION iI 2-I/16'• + fALTERNATEJ i .. I il L40" 7 1/2" ' 29 I/2..20-1/4" 20 1/4" 10,• 13-3/4" �E 4 10" V 1/2"—�— 1-1/2" DIA. HOLE A GAS CONNECTION 5 5/16" f - 28-1/2"� MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS OpET D OUTLET .1xET°. M.Ol�Eii 91�.OIIw.i0p .'7"""' AIR wnE.'11B µ`•solo '81ri ht.'`4)°, xD MI 1I J— PEC I4 p1SE.-vu i p•TpKE=O° "Op i=ONi•L CLOSET IPLDE DIED"MpE LEETI OLE wKL vE x.-2 Ix,wiTrPE 3/4" P" 74+'"a1 FT- I)Vw r E a'1.I C; 'I w�. I °^°x. 3/4" 19 8-1/4" "s=•�I =� "op.:DxT.L D x plpxTl snow.i'"ii""wwisll°LI®.ci `vVI"-I°ltis.rr p-I""T MODEL A B C D PxEx'o°T.s..�ox�ED.aa°c°ucEOE PLDDpI"O Dx�r TDD040R924 xop l=DxT.L 4DDVE IPLDE DIpE"MDE LEPTI TDD060R936 14-1/2" 9-5/8" 13-1/4" 13" :as�T°. 'I.x:p 41o'FT''Ise ;.P a:t."T' .Ix TDD080R936 17-1/2" 9-5/8" 16-1/4" 16" x°pl=DxT.L.DD.E IPLDE DI°=".ppE xlpx„ TDD100R945 E" rN T Mt,- ip Ix. p.DR EYE-- .iti O PIN°-vExT TDD100R948 21" 13-1/16" 19-3/4" 19-1/2" TDD100R960 TDD120R960 24-1/2" 15-5/16" 23-1/4" 23" TDD140R960 From Dwg.21C340804 Rev.8 PUB.NO.22-1672-03-998(EN) 11 pESIGN ilt‘e(t\C41 ( �CIAT� R APPNDVED ....)CERTIFIES TWINE' P.I. The Trane Company Unitary Products Group 6200 Troup Highway Tyler,TX 75707 Since The Trane Company has a policy of continuous product improvement,it reserves the right to change An American-Standard Company design and specifications without notice.