HomeMy WebLinkAboutReport (3) ME G/,bt3•661t3
SEC II
12060 Sw MSfril(gegPeYt HVAC Additio
12060 SW Main Street
Tigard, OR 97223
CITY OF TIGARD
BUILDING DIVISION
Climate Control
16500 SW 72"d Ave
Portland, OR 97224
Job Number
2023025
Project Description
The addition of(14) RTUs on an existing roof
Table of Contents
Design Information C-1 thru C-4
Calculations C-5 thru C-11 .<�¢�G PN OFFss/
Reference Sheets R-1 thru R-7 Lc, ��
cr 85997 v
OR :•N
s�<AsP7a2ob���
FNMARKS'\
EXPIRES:06-30-2024
Permit Set September 26, 2023
1111111111111
StenBERG Design
c - 1
ASCE 7 Hazards Report
AMERicAN SOC!EI,OF CIVIL ENSINEERS
Address: Standard: ASCE/SEI 7-16 Latitude: 45.432014
12060 SW Main St Risk Category: II Longitude: -122.766113
9Portland, Oregon Soil Class: D Default (see Elevation: 0 ft(NAVD 88)
Section 11.4.3)
4
w
'ter
�
L
d Pbatl.4,7
k rya.,t.t
rr�C�
t t t o t�rr-t
N'f 5
Tyyand ",,a _
r.
Wind
Results:
Wind Speed 97 Vmph
10-year MRI 66 Vmph
25-year MRI 73 Vmph
50-year MRI 77 Vmph
100-year MRI 82 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4, and Section 26.5.2
Date Accessed: Tue Sep 26 2023
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability=
0.00143, MRI = 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
https://asce7hazardtool online/ Page 1 of 3 Tue Sep 26 2023
C - 2
rMERU NSENSEiP'DiCIVILENGINEERS
Seismic
Site Soil Class: D - Default (see Section 11.4.3)
Results:
Ss : 0.862 Sp, N/A
Si : 0.395 TL : 16
Fa : 1.2 PGA : 0.392
F, : N/A PGA M : 0.473
SMs : 1.034 FPGA 1.208
SMi : N/A le : 1
Sos 0.689 C, : 1.231
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8.
Data Accessed: Tue Sep 26 2023
Date Source: USGS Seismic Design Maps
https://asce7hazardtool.online/ Page 2 of 3 Tue Sep 26 2023
C - 3
AM RIC N SOCTEIY Eir NIi.ENGINEERS
Snow
Results:
Ground Snow Load, pg : 11 lb/ft2
Mapped Elevation: 0.0 ft
Data Source:
Date Accessed: Tue Sep 26 2023
Statutory requirements of the Authority Having Jurisdiction are not included.
Snow load values are mapped to a 0.5 mile resolution. This resolution can
create a mismatch between the mapped elevation and the site-specific
elevation in topographically complex areas. Engineers should consult the local
authority having jurisdiction in locations where the reported `elevation'and
`mapped elevation'differ significantly from each other.
The ASCE 7 Hazard Tool is provided for your convenience,for informational purposes only,and is provided"as is"and without warranties of
any kind.The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard.While ASCE has made every effort to use data obtained from
reliable sources or methodologies,ASCE does not make any representations or warranties as to the accuracy,completeness,reliability,
currency,or quality of any data provided herein.Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship,or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret,the results provided by this Tool to replace the sound judgment of a competent
professional,having knowledge and experience in the appropriate field(s)of practice,nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers,directors,
employees,members,affiliates,or agents be liable to you or any other person for any direct,indirect,special, incidental,or consequential
damages arising from or related to your use of,or reliance on,the Tool or any information obtained therein.To the fullest extent permitted by
law,you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
https://asce7hazardtool.online! Page 3 of 3 Tue Sep 26 2023
Stephen Mark Stenberg, PE
StenBERG Design C —
4
PO Box 1135
Beaverton,OR 97075
ASCE Seismic Demands on Nonstructural Components Project File: Herford's Equipment Support.ec6
LIC#:KW-06019804,Build:20.23.08.30 -
StenBERG Design (c)ENERCALC INC 1983-2023
Seismic Demands on Nonstructural Components per ASCE 7-16 Section 13.3.1 and 13.4.1
h = 20.0 ft S DS = 0.6890
Description : Typical RTU
a = 2.50 W P= 649.0 z = 20.00 ft R = 6.00 I = 1.00 z/h :Actual = 1.00 z/h Design = 1.00
Fp Upper Limit = 715.46 Fp Calc'd :Components= 223.58 Fp DESIGN : Components = 223.58
Fp Lower Limit = 134.15 Connections= 223.58Connections =
_-_ 223.58
a : Component amplification factor, Table 13.5-1 or Table 13.6-1 Fp-Calc'd : Calculated Fp, Eq(13.3-1),Same units as Wp
W P : Component operating weight
Z Height of point of attachment Fp-Upper : Upper Limit on Fp, Eq(13.3-2) ,(Same units as
R P Component response modification factor(Table 13.5-1 or Table Fp-Lower : Lower Limit on Fp, Eq(13.3-3),Same units as 1
I P : Component importance factor(Section 13.1.3) Fp-Design : Fp for design purposes, Same units as Wp
. CALCULATION: HVAC ADDITION C - 5
Check Existing Roof Structure References
The new RTU equipment is intended to replace the existing HVAC system which consists
of a condensing unit and airhandler. The units are to be placed along the existing beam
lines near the columns to minimum the added stress to the existing members (joists and
beams). Blocking between joists and beams is to be added under all sides of the
Type Weight
RTU 556 lbs see reference sheets
Curb 93 lbs see reference sheets
DL 15 psf roof dead load
SL 25 psf roof snow load
EXISTING STRUCTURE IS OK DUE TO ADDED STRESS INCREASE < 5% see following calculations
Design Wind and Seismic Load Path
The RTUs are to be secured to a curb with prefabricated holdowns (see reference
sheets). The curb is then attached to the new and existing structure with perimeter
fasteners. See the following analysis for the design of the connections to the roof
Wind Load ASCE 7-16: Section 29.4.1
Kz 0.75 velocity pressure coefficient ASCE 7-16: Section 26.10.1
Kzt 1.00 topographic factor ASCE 7-16: Section 26.8.2
Kd 0.85' wind directionality factor ASCE 7-16: Section 26.6
Ke 1.00; ground elevation factor ASCE 7-16: Section 26.6
V 98 "mph design wind speed ASCE 7-16: Section 26.6
qh 15.67 psf 0.00256 x Kz x Kzt x Kd x Ke x V2 ASCE 7-16: Eq. (26.10-1)
B "'162 ft horizontal dimension of building perpendicular to wind ASCE 7-16: Section 26.3
h 20 ft mean roof height of building/structure ASCE 7-16: Section 26.3
L 178 ft horizontal dimension of building parallel to wind ASCE 7-16: Section 26.3
Af 24 sf horizontal projected area of equipment ASCE 7-16: Section 29.4.1
Ar 24 sf vertical projected area of equipment ASCE 7-16: Section 29.4.1
Bh 3240 sf horizontal projected area of building
BL 28836 sf vertical projected area of building
GCr 1.90 horizontal gust factor ASCE 7-16: Section 29.4.1
GCr 1.50 vertical gust factor ASCE 7-16: Section 29.4.1
Fh 728.7 lbs qh x GCr x Af ASCE 7-16: Eq. (29.4-2)
0.6Fh 437.2 lbs ASD
Fv 566.2 lbs qh x GCr x Ar ASCE 7-16: Eq. (29.4-3)
0.6Fv 339.7 lbs ASD
StenBERG Design
P.O. Box 1135
Beaverton, OR 97075
cell: 541.399.2656 I email: stephen@stenbergdesign.com
Stephen Mark Stenberg, PE
StenBERG Design C — 6
PO Box 1135
Beaverton, OR 97075
General Beam Analysis Project File: 12060 SW Main Street HVAC Addition.ec6
LIC#:KW-06019804,Build:20.23.08.30 StenBERG Design (c)ENERCALC INC 1983-2023
DESCRIPTION: Proposed Moment on Existing Joist (32" o.c. spacing) -Worst Case
General Beam Properties
Elastic Modulus 29,000.0 ksi
Span#1 Span Length = 35.0 ft Area= 10.0 inA2 Moment of Inertia = 100.0 inA4
D(0.163)
it
D(0_04005)S(0-06675)
Span= 35-0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D=0.0150, S=0.0250 ksf, Tributary Width =2.670 ft, (Existing Loading)
Point Load : D=0.1630 k @ 3.870 ft, (RTU (1/4 or corner load))
DESIGN SUMMARY
Maximum Bending = 16.671 k-ft Maximum Shear= 2.014 k
Load Combination +D+S Load Combination +D+S
Span#where maximum occurs Span#1 Span#where maximum occurs Span#1
Location of maximum on span 17.325 ft Location of maximum on span 0.000 ft
Maximum Deflection
Max Downward Transient Deflection 0.000 in 0
Max Upward Transient Deflection 0.000 in 0
Max Downward Total Deflection 0.000 in 0
Max Upward Total Deflection 0.000 in 0
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Summary of Mom..nt Values (k-ft) Shear Values (k)
Segment Length Span# M V Mmax+ Mmax- Ma-Max nx Mnx/Omega Cb Rm Va Max VnxVnx/Omega
Overall MAXimum Envelope
Dsgn. L= 35.00 ft 1 16.67 16.67 2.01
+D+S
Dsgn. L= 35.00 ft 1 16.67 16.67 2.01
Overall Maximum Deflections
Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span
1 0.0000 0.000 0.0000 0.000
Vertical Reactions Support notation : Far left is#' Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 2.014 1.887
Overall MINimum
+D+S 2.014 1.887
D Only 0.846 0.719
S Only 1.168 1.168
Mdesign=wL2/8= 16.354 k-ft
(Maximum Bending/Mdesign)-1 =0.019—1.9%INCREASE
Allowable Increase=5%[2022 OSSC Section 3411.3.1]
THEREFORE EXISTING JOIST IS ADEQUATE
Stephen Mark Stenberg, PE
StenBERG Design C - 7
PO Box 1135
Beaverton,OR 97075
Wood Beam Project File: 12060 SW Main Street HVAC Addition.ec6-ii
LIC#:KW-06019804,Build:20.23.08 30 StenBERG Design (c)ENERCALC INC 1983-2023
DESCRIPTION: Existing GLB (Double Cantilever)
CODE REFERENCES
Calculations per NDS 2018, IBC 2021, ASCE 7-16
Load Combination Set: IBC 2021
Material Properties
Analysis Method : Allowable Stress Design Fb+ 2400 psi E:Modulus of Elasticity
Load Combination: IBC 2021 Fb- 2400 psi Ebend-xx 1800ksi
Fc-Pr!! 1650 psi Eminbend-xx 950 ksi
Wood Species DFlDF Fc-Perp 650 psi Ebend-yy 1600 ksi
Wood Grade 24F-V8 Fv 265 psi Eminbend-yy 850 ksi
Ft 1100 psi Density 31.21 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D(6.03)S(10.05) D(0.166) D(5.03)S(8.38)
D(0.5025)S(0.8375) a a a s a
D(0.166) D(0166) '._ a a
a D(btatto.166)
t
6.75x30 6.75x30 t,
6 75x30
Span=7.0 ft Span=32.330 ft Span=6.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight NOT internally calculated and added
Loads on all spans...
Uniform Load on ALL spans : D=0.0150, S=0.0250 ksf, Tributary Width =33.50 ft
Load for Span Number 1
Point Load : D =6.030, S = 10.050 k @ 0.0 ft, (Hung Span)
Uniform Load : D=0.1660 k/ft, Extent=3.50--» 7.0 ft, Tributary Width= 1.0 ft, (RTU)
Load for Span Number 2
Uniform Load : D=0.1660 k/ft, Extent=0.0--»2.50 ft, Tributary Width = 1.0 ft, (RTU)
Uniform Load : D=0.1660 k/ft, Extent=28.50--» 32.330 ft, Tributary Width= 1.0 ft, (RTU)
Load for Span Number 3
Point Load : D=5.030, S =8.380 k @ 6.0 ft, (Hung Span)
Uniform Load : D=0.1660 k/ft, Extent=0.0--»2.0 ft, Tributary Width = 1.0 ft, (RTU)
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.739: 1 Maximum Shear Stress Ratio = 0,543 : 1
Section used for this span 6.75x30 Section used for this span 6.75x30
fb:Actual = 1,735.19 psi fv:Actual = 165.34 psi
F'b = 2,346.47 psi F'v = 304.75 psi
Load Combination +D+S Load Combination +D+S
Location of maximum on span = 0.000ft Location of maximum on span = 4.529 ft
Span#where maximum occurs = Span#2 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward Transient Deflection 0.156 in Ratio= 1074>=360 Span:3:S Only
Max Upward Transient Deflection -0.010 in Ratio= ' 764>=360 Span:2 :S Only
Max Downward Total Deflection 0.251 in Ratio= 668>=180 Span:3:+D+S
Max Upward Total Deflection -0.016 in Ratio= 23523>=180 Span:2 :+D+S
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Moment Values Shear Values
Segment Length Span# M V CD CM Ct CLx Cv Cfu C i C r M fb F'b V fv F'v
+D+S
0.0 0.00 0.0 0.0
Length=7.0 ft 1 0.635 0.543 1.15 1.00 1.00 1.00 0.991 1.00 1.00 1.00 146.41 1,735.2 2,734.4 22.32 165.3 304.8
Stephen Mark Stenberg, PE
StenBERG Design C — 8
PO Box 1135
Beaverton,OR 97075
Wood Beam Project File: 12060 SW Main Street HVAC Addition.ec6
LIC#:KW-06019804,Build:20.23.08.30 StenBERG Design (c)ENERCALC INC 1983 2023
DESCRIPTION: Existing GLB (Double Cantilever)
Maximum Forces & Stresses for Load Combinations
Load Combination —Max Stress-Ratios Moment Values Shear Val-Lies
Segment Length Span# M V CD CM Ct CLx Cv Cfu C i Cr M fb F'b V Iv F'v
Length=32.330 ft 2 0.739 0.543 1.15 1.00 1.00 1.00 0.850 1.00 1.00 1.00 146.41 1,735.2 2,346.5 19.70 165.3 304.8
Length=6.0 ft 3 0.451 0.543 1.15 1.00 1.00 1.00 1.000 1.00 1.00 1.00 104.91 1,243.4 2,760.0 18.14 165.3 304.8
Vertical Reactions Support notation: Far left is#1 Values in KIPS
Load Combination Support 1 Support 2 Support 3 Support 4
Max Upward from all Load Conditions 49.422 42.774
Max Upward from Load Combinations 49.422 42.774
Max Upward from Load Cases 30.240 26.154
+D+S 49.422 42.774
D Only 19.182 16.620
S Only 30.240 26.154
Stephen Mark Stenberg, PE
StenBERG Design C - 9
PO Box 1135
Beaverton,OR 97075
Wood Beam Project File: 12060 SW Main Street HVAC Addition.ec6
LIC#:KW-06019804,Build:20.23 08.30 StenBERG Design (c)ENERCALC INC 1983-2023
DESCRIPTION: Existing GLB (Single Cantilever)
CODE REFERENCES
Calculations per NDS 2018, IBC 2021,ASCE 7-16
Load Combination Set: IBC 2021
Material Properties
Analysis Method : Allowable Stress Design Fb+ 2,400.0 psi E:Modulus of Elasticity
Load Combination IBC 2021 Fb- 2,400.0 psi Ebend-xx 1,800.0 ksi
Fc-Prll 1,650.0 psi Eminbend-xx 950.0 ksi
Wood Species : DF/DF Fc-Perp 650.0 psi Ebend-yy 1,600.0 ksi
Wood Grade : 24F-V8 Fv 265.0 psi Eminbend-yy 850.0 ksi
Ft 1,100.0psi Density 31.210pcf
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D(5 03)S(8 37)
D(0.5025)S(0.8375)
F -U(O.1bb) U(0,1bb) b b ---- --- b
b b b b b b b b b b
6.75x33 6.75x33
Span=6.0 ft Span=37.670 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight NOT internally calculated and added
Loads on all spans...
Uniform Load on ALL spans : D =0.0150, S=0.0250 ksf, Tributary Width =33.50 ft
Load for Span Number 1
Point Load : D=5.030, S =8.370 k @ 0.0 ft, (Hung Span)
Uniform Load : D=0.1660 k/ft, Extent=3.0-->>6.0 ft, Tributary Width= 1.0 ft, (RTU)
Load for Span Number 2
Uniform Load : D=0.1660 k/ft, Extent=0.0--»2.50 ft, Tributary Width= 1.0 ft, (RTU)
DESIGN SUMMARY + ,..Desi=n OK
Maximum Bending Stress Ratio = 0.806 1 Maximum Shear Stress Ratio = 0,538 : 1
Section used for this span 6.75x33 Section used for this span 6.75x33
fb:Actual = 1,843.35 psi fv:Actual = 164.00 psi
F'b = 2,288.95 psi F'v = 304.75 psi
Load Combination +D+S Load Combination +D+S
Location of maximum on span = 20.834ft Location of maximum on span = 6.000 ft
Span#where maximum occurs = Span#2 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward Transient Deflection 0.775 in Ratio= 583>=360 Span:2 :S Only
Max Upward Transient Deflection -0.263 in Ratio= 548>=360 Span: 1 : S Only
Max Downward Total Deflection 1.239 in Ratio= 364>=180 Span:2:+D+S
Max Upward Total Deflection -0.419 in Ratio= 342>=180 Span: 1 :+D+S
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Moment Values Shear Values
Segment Length Span# M V CD CM Ct CLx Cv Cfu C i Cr M fb F'b V fv F'v
+D+S 0.0 0.00 0.0 0.0
Length=6.0 ft 1 0.375 0.538 1.15 1.00 1.00 1.00 0.997 1.00 1.00 1.00 105.27 1,031.1 2,750.6 24.35 164.0 304.8
Length=37.670 ft 2 0.805 0.538 1.15 1.00 1.00 1.00 0.829 1.00 1.00 1.00 188.19 1,843.3 2,289.0 24.35 164.0 304.8
Stephen Mark Stenberg. PE
StenBERG Design C — 1 0
•
PO Box 1135
Beaverton,OR 97075
Wood Beam Project Filer 12060 SW Main Street HVAC Addition.ec6
LIC#:KW-06019804,Build:20.23.08.30 StenBERG Design (c)ENERCALC INC 1983-2023
DESCRIPTION: Existing GLB (Single Cantilever)
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2 Support 3
Max Upward from all Load Conditions 50.373 22.458
Max Upward from Load Combinations 50.373 22.458
Max Upward from Load Cases 30.903 14.041
+D+S 50.373 22.458
D Only 19.470 8.417
S Only 30.903 14.041
CALCULATION: HVAC ADDITION C - 11
Design Wind and Seismic Load Path (cont.) References
Seismic Load
1.0 x Fp 224.0 lbs see previous calculations
Design RTU Anchorage:
x 47 in unit width see reference sheets
z 47 in unit height see reference sheets
Sds 0.689 design spectral acceleration
Mot_W 30459.1 lb-in overturning moment due to lateral and uplift loads (1.0W)
Mresist_W 13616.8 lb-in resisting moment due to equipment self weight(0.9D)
OT- Resist 16842.3 lb-in SEE BELOW TENSION PER FASTENER
Mot_E 5306.0 lb-in overturning moment due to lateral and uplift loads (1.0E)
Mresist_E 11531.9 lb-in resisting moment due to equipment self weight(0.9D-0.2Sds)
OT- Resist -6225.9 lb-in NO UPLIFT-SEE ABOVE WIND LOADING
W-Tmax 361.2 lbs E -Tmax -133.5 lbs
W-Vmax 566.2 lbs E -Vmax 0.0 lbs
#fasteners 8 minimum number of fasteners
0 0 overstrength ASCE 7-16: Table (13.6-1)
Tmax 90.3 lbs OTmax 0.0 lbs max tension per fastener
Vmax 70.8 lbs OVmax 0.0 lbs max shear per fastener
SEE BELOW ANCHORAGE DESIGN
try#12 wood screw
Zperp 147 lbs allowable single shear load (1"wood side/ DFL main) NDS: Table 12L
W 172 lbs/ in allowable withdrawal value per inch penetration (G = 0.5:NDS: Table 12.28
CD 1.6 wind /earthquake load duration factor NDS: Section 2.3.2
Z' 235.2 lbs design shear value
W' 412.8 lbs design withdrawal value based on 1.5 inch penetration
load 71 + 90 = 0.52
capacity 235.2 + 413
RTU -CURB: USE (4) HOLDOWNS WITH #12 x 1 1/2" TEK SCREWS INTO RTU AND CURB
CURB - ROOF: USE#12 x REQ'D SCREW WITH 1.5" MINIMUM PENETRATION
StenBERG Design
P.O. Box 1135
Beaverton, OR 97075
cell: 541.399.2656 I email: stephen@stenbergdesign.com
R - 1
5T
Project: Savers Tigard 08/11/2023
Prepared By: 11:28AM
5T
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Unit Feature Sheet
Spec Sheet
Packaged Rooftop Builder 1.75 Page 1 of 10
R - 2
Unit Report For 5T
Project: Savers Tigard 08/11/2023
Prepared By:
11:28AM
Unit Parameters Dimensions (ft. in.)&Weight(lb.)***
Unit Model: 48FCDA06A2A5-0AOA0 Unit Length: _ 6' 2.375"
Unit Size. 06 (5 Tons) Unit Width: 3' 10.625"
Volts-Phase-Hertz: 208-3-60 Unit Height: 2' 9.375"
Heating Type: Gas Total Operating Weight: 556 lb
Heat Control: Low Heat
Duct Cfg: Vertical Supply/Vertical Return "' Weights and Dimensions are approximate. Weight does
not include unit packaging. Approximate dimensions are
DX Options: Standard One Stage Cooling Models
provided primarily for shipping purposes.For exact
dimensions and weights,refer to appropriate product
data catalog.
Lines and Filters
Gas Line Size: 1/2
Condensate Drain Line Size: 3/4
Return Air Filter Type: Throwaway
Return Air Filter Quantity: 2
Return Air Filter Size: 16 x 25 x 2
Selection includes construction throwaway filter into the base fan curve.
Unit Configuration
Direct Drive-EcoBlue- Medium Static
Al/Cu-Al/Cu
Base Electromechanical Controls
Standard Packaging
Warranty Information
1-Year parts(std.)
5-Year compressor parts(std.)
10-Year heat exchanger-Aluminized(std.)
No optional warranties were selected.
NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods.
Ordering Information
Part Number Description Quantity
48FCDA06A2A5-OAOAO Rooftop Unit 1
Base Unit
Direct Drive- EcoBlue-Medium Static
None
Packaged Rooftop Builder 1.75 Page 2 of 10
•
Certified Drawing for 5T
Project: Savers Tigard 08/11/2023
Prepared By: 11:28AM
rq'arrte� I N , ry OF E E
c
N N P
uND ES — TRW!NC CONTENTS WILL NOT BCN16 OS,f OF n6o CL E9 Can n,Ttl�nr*snnM�Lw WRITTEN CONSENT)IMRNA1OAS ARE 1N INCLES 71MEn5 ONS Gh 0..0, 3A3 18,75218
iR1In I 1 AAE 'N vll MCTFRG -..- IN -- - -- CONNECTION 5
7. 1 CFNI/R Ot /AV,1V n8Fr''06 }8 1,8 n?1 _ _
ZE.
B 3 3/A 114 7/81 33-3/8 A 1 3/8" [351 DIA FIELD WO SO P L'1
PIR CT,ON OF AIR I.OW ��� 84, 7 [8487 -— --
I - C B 2" [591 DIA EWER SUPPLY ANOCNO
P 8 /
1 8 ni07 '8 32-"/8 —
511 — C 3/A" E51� DIA 6A 10E ACCESS PI OF
� 1
((� ALI. VIEW DRAWN USING 3iS AUGHT =7?1 18171 ` ECONOMIZER HOOD
Y' [OPTIONAL] D 7/8" [22/ DIA FIELD CONTROL.WIRING IOI
[AD'11 E 3/4"-14 NEI CONDENSATE DRAIN
r 25-518 16
652] F 1/2"-14 NPT GAS CONNECTION
. .. .. RETURN AIR G 2 1/2 I64 014 POWER SUPPLY KNOCK OU .',
7— • RN"
I
1
������ L THRU-THE-BASE CHART
10-7/8 RETURN THESE HOLES 8A00, EO FOR USE
/ /� \ e - [2771 AIR THREADED
TWROOBA00, 009A00
•'�/!//"�/// ,��I,11!'IIII o • THREADED WIRE REO'D HOLE
` CONDUIT SIZE USE SIZES IMA%.1
4d-1 IS =� • % 1/2" 24V 7/8" i22 2]
. . Y E ALT. J : [74812 Y 3/4" POWER 1-1/8" [28.6]
[i120 9!
w_ CONDENSATE 77-3/4 Z. (009A00A 7/2" FPT i GAS 1-1/8" C28.61
"-- Z DAMN OPENING [451]
A IN BASEPAN SUPPLY 26-5/B FOR "TNRU-THE-B ASEPAN" FACTORY OPTION,
_ [! � SUPPLY FITTINGS FOR ONLY %, Y, 8 Z ARE PROVIDEDI
Id-I/2 } .. \'\. AIR [5151 AIR + [008A00) PROVIDES 3/4" FPT THEW CURB
E 369] 131110 11-I/2 J SEE TRRU THE �3 FLANGE 8 FITTING. J
81 [29i31 BASE
.. CHART
T I . ..�� L
10-1/8 J 2% 23-3/4 3-114 -"-- - 6-1/4
[256] [603] ( f81] 11581
LL
d UE 12-1/9
FL
E101] HOOD [307]
2% 25 18-3/e
T -- [635] [466]
2x 4-5/8 TOP
1/18]
E STD.
E LECTRiC AL CONDENSATE —"1 10-7/8 r- f 1
DISCONNECT DRAIN [275] + 1251
LOCATION ]'-
11 CONDENSER _ --A,B,G OPTIONAL CONTROL 80% o��� �IL TER
COILI FACTORY ACCESS PANEL '
INSTALLED INDOOR BLOWER 17-3/B �•I 21-3/d
_ DISCONNECT ACCESS PANEL [441] I [6531
s
OPTION AI — _ SUPPLY AIR I I _RETURN '' _�
INSTALLED -D 1 = l =
CONVENIENCE a 4 -
7.
00'L FT >r I.
• — ___T ,9-1/2 - _ HANDLE liii
11-7/8 � I I I YH
E I
T n6 5/e —I
3-3/4 HANDLE 8-3/8 5-3/4 L 6-3/8 T 7 5-3/4
[951 111861 - 30-1/8— [2141 !146] [161] C1771 [146i
r1766i 26-7/A
6821
LEFT ^-- 74-3/8 31 —.-
[18891 [786] BAROMETRIC
RELIEF
FRONT SAIAPLY I FLOW
UP fRETURN '..
RIGHT AIR
ITC CLASSIFICATION I SHEET DATE I SUPERCEDES --'-
48 FC 04-01 SINGLE PACKAGE ELECTRICAL REV
48TC003093
-- U.S. ECCN;NSR I 1 OF 3 09/07/18 06/22/18 I COOLING WITH GAS HEAT A II 1
Packaged Rooftop Builder 1.75 Page 3 of 10
W
Certified Drawing for 5T
Project: Savers Tigard
/2023
Prepared By: 0811 :28AM
128AM
THIS DOCUNENI IS THE AAOPEATv DA UTC CLIueT.COAT0C2 8
STD. UNIT CORNEA CORNER CORNER CORNEA CC[lf1'rlB�a s[cuNlrr AxD s DELiv[AED 1 0/r/0 Exp50 4 11 T:oN suax lss DW of Ix[s[DAAv[ns o Do WENT.S'
THAT 1N[CONTENTS WILL x01 9E DISCLOSED OR USED DDCS x01 CONSillll`E P<Ai p[ [OR
UNIT WEIGHT + NE IGHT (A) WEIGHS :8) WEIGHT (C1 WEIGHT (D) G'G' HC]GHT Qw�aT�nmy� WIi NOIIi Nx1iiEN CONSENT ACCEPTANCE OF CONTRACT
LBS. KG 5S. KG. Al[ NG. LBS. KG. LBS_1 KG. X 7 7
'48FC4.04 482 219 113 • 51 116 53 128 58 125 157 37 5/8 [956] 24 9/16 [6241�. 18 1/4 14641
4810 +05 543 246 138 63 1133 60 133 60 138 63 36 1/2 [927] 23 3/8 [594J 1 18 [457]
-486C +95 556 252 1 142 64 T 1 62 36 62 ' 142 64 36 1/2 [9271 23 3/8 [5941 118 [4571
148 C+10/ 607I 275 162 1 73 I 1S? 69 141 i 64 1 151 1 68 36 [914] i 22 1/2 [5721 1 19 3/8 [4921
STANDARD UNIT WEIGHT IS WITH LOW GAS PEAT AND WITHOUT PACKAGING.
FOR OTHER OPTIONS AND ACCESSORIES, AEFEH TO THE PRODUCT DATA CATALOG.
BACK
R12 1/2 WITH ECONOMIZER
BACK 3181 \ I ,5
CO A WITHOUT L
CORNER B ECONOMIZER OPTIONAL DOOR •
ECONOMIZER
(OPTIO A000
0 - - - SWING
O .,�
t
%ice\\ - :ll��.) !1 0 , A R ICH I
•
� ) (IU,A//br nlllll�
CORNER
CORNER C LEFT
J
TOP
I'.896i 4 s/e
FRONT
_J NOTES: CLEAA ANCES LOCAL CODESORJRISD ICT TONS 4AY PREVAi L.Li11i
j_ OPTING
_ ®O SURFACE CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER CLEARANCE
1� ® �_ »_ �� 1 FRONT 48 1219mm] 36 [9"4mm] �8 (407009.
-- - -- - LEFT 48 I12190,1 42 IIC67mm1 18 1457 1-
FRONT BACK 48 [1219mmi 42 [1067mm7 18 [4519m1�
BACK W/H000 36 [9'4mmi 36 [914mmi 18 I4.57mm)
RIGHT 36 [914mm] 36 [914mm] 18 [4570)m1
TOP 72 [1829mm] 72 [1829m0)] 72 [1829mm1
I
ITC CLASSIFICATION SHEET PATE SUPERCEOES
48FC 04-07 SINGLE PACKAGE ELECTRICAL A[v
U.S. ECCN.NSR 2 OF 3 09/07/18 1 06/22/18 COOLING WITH GAS HEAT 48TC 003093
Packaged Rooftop Builder 1.75
Page 4 of 10
4
Certified Drawing for 5T
Project: Savers Tigard 08/11/2023
Prepared By: 11:28AM
CCarr1e7-)rFprC�e a"rE,,,,r. ,Liv E uva ixe ESP"xis'oo,NTROLS sUBMISSiOx OF TRESS DRAW:Nrs DR DOC•MRNTS1
THE CONTENTS WILL NOT BE DISCLOSED OR USED DOES NOT CONSTITJTE PART NERFONUANCF ON
O unuwisnroby. WITHOUT WRITTEN CONSENT. ACCEPTANCE C�<0.1'T RnC i.
71-1/8
[1805.31
(INSIDE THE BASE RAIL A SKIRT)
•
HI
0 )INSIDE THE BASE PAILS)
004
CJ1111*°1 � /
�''1�.�'.'�� INSIDE BASERAIL DIMENSIONS i zx ie6i� I
.3411# 7/8
481 e BOTTOM o
o
I 2X T
— 1.3/8 2X ,
31/4 '_ L361 i251 I
[62] -----I — 2X 3/4
DETAIL C --. 3-7/8 [161 11I
P 4 PLCS as
FILTER ACCESS PANEL I. COMP
ITOOL-LESS) ACCESS ACCESS
PANEL INDOOR
AC 00 S PANEL
. PANE]
•
.O. ! 1 yyy
• INDOOR COIL _ _ SEE DETAIL C
ACCESS PANEL - --
• I
l� - o r E-7/6 - O- e
74 O I 1 I F=a- 9 '� ] 9 o 6 rf'u_�1� i ► i •(I d [ 6 i C—�' i ---„-, t ! I o C.;
BACK LEFT 3-114 --- --- 59-3/8 — —� 2 3/e
[82.01 [1509.01
7.1/8 r 1E 1.NEE
PU '.,I
P
FRONT [I8C 7' WIDTH 1
'TC CLASSIFICATION I SHEET DATE I SUPERCTDES
482C 04 07 S;NGL FACdA6E ELECTRICAL
KO
COO' WITH CO H£Ai 48T0003093
U.S. ECCN.NSR j 3 OF 3 09/07/18 06/22/18 G f1
Packaged Rooftop Builder 1.75 Page 5 of 10
V7
-
- - r a I .A -
it."--+fr �:.n.. ,�P t'.
, �.:9', „� �.'nGas .. - 'te max_., - _. ,
£,�
-s �
_
M, .. .. .maw.......
? '
:i =i: . I-,, ..;,.�. !t!' h,�..:.
Grp
• t
..,:, i, f-1,7": '''-''''''' '':.:,": ,:;'-'1'A:::::4114',:'
n vus
c �
�.«
I
_�r.>,, } $fin
z
„y,. -.. ._ 'i";"Y' C. .S .i ez x�r� i ,+nk #"zrx Mgr g
;mac
,
,._. „w. ._ ..... .,
F
j a\n ��\ r z �k
,
,.e
- -.- 'tt.. - Kaf MmsMY.0 s.NNWj � '
ur
4.4 � J~ - _ l _ CYO M..,_ ..
R
-+,,-,... i ..,
11
,ti 4, -CY+`cC4LEG 3,p Yk #gL{$£p Asa YB ` x'SAG'iR NO.
.yy bx
#Y �y
I m 'i'ktM p .14,1, Ir TJt
I
C)
SUBMITTAL - MicroMeti
See Attached Page for Units Part Number:
0406-0100-00000
FORM NO. 4250-2D I 4/29/2015
Submitted To:
Company:
Job Name: 1.875°
Notes:
-Hold Down Brackets ° Quantity (4)
Hold-Down brackets
NOTES O °
1" O
• The Addition of I1okl I)own Brackets Do Not Provide O
Wind or Seismic Certification
• Assembly hardware Pt(Aided
• Secures Rooftop trim to Curt) /•
4.500"
1.375"
o
O
o
2.875" 6„
THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT
MicroMetl Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks Nevada— 1-800-884-4662, Longview Texas — 1-903-248-4800 ~