Report (2) r I Submittal Data Sheet RECEIVED 1.5-Ton Duct Concealed and Heat Pump FDMQ18WVJU9RXL18WMVJU9 SEP 1 8 2023 Model Indoor Unit CITY OF I IG '; QI8WVJU9 Outdoor Unit BUILDING D(Vli!�` 18WMVJU9 Cooling Heating Power Supply 1 cp, 208 - 230 V, 60 Hz Capacity Rated (Min. - Max.) Btu/h 17,600 (9,000 - 9,600) 21,600 (9,000 - 5,000) Running Current (Rated) A 8.79 - 7.95 10.50 - 9.50 Power Consumption (Rated) W 1,760 - 1,760 2,110 - 2,110 Power Factor (Rated) % 96.3 - 96.2 96.6 - 96.6 SEER2 / HSPF2 15.20 8.50 EER2 (Rated) Btu/h•W 10.00 — COP2 (Rated) WAN — 3.00 Piping Liquid in. (mm) cp 1/4 (6.4) Connections Gas in. (mm) cp 1/2 (12.7) Drain in. (mm) I.D. cp 1 (25) / O.D. cp 1-1/4 (32) Heat Insulation Both Liquid and Gas Pipes Max. Interunit Piping Length ft (m) 98-1/2 (30) Max. Interunit Height Difference ft (m) 65-5/8 (20) Chargeless ft (m) 32-3/4 (10) Amount of Additional Charge of oz/ft 0.32 (30) Refrigerant (g/m) Indoor Unit FDMQI8WVJU9 Heat Rows x Stages, Fin/ Inch 3 x 26, 18 Exchanger Fin Spec/ Tube Multi Slit Fin / cp 5 Hi-XA Tube Airflow Rate H / M / L cfm 614 / 523 /431 614 / 523 /431 m3/min 17.4 / 14.8 / 12.2 17.4 / 14.8 / 12.2 Fan Motor H / M / L rpm 1,023 / 870 / 717 1,023 / 870 / 717 Motor Output HP 0.31 Fan Type Sirocco Fan External Static Pressure inH2O Standard 0.20 (0.60 - 0.20) Pa Standard 50 (150 - 50) Running Current (Rated) A 0.69 - 0.62 0.69 - 0.62 Power Consumption (Rated) W 131 - 131 131 - 131 Power Factor (Rated) % 91.2 - 92.2 91.2 - 92.2 Dimensions (H x W x D) in. (mm) 9-5/8 x 39-3/8 x 31-1/2 (245 x 1,000 x 800) Weight (Mass) lbs (kg) 82 (37) Sound Pressure Level dB(A) 35 35 Remote Controller (Option) Wired BRC1 E73 Wireless BRC082A43 Daikin Comfort Technologies North America,Inc 19001 Kermier Rd Waller TX 77484 Daikin City Generated Submittal Data www.daikincomfort.com or www.daikinac.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications,and information in this data sheet without notice and without incurring any obligations) Submittal Data Sheet 1.5-Ton Duct Concealed and Heat Pump FDMQ 18 W VJU9RXL 18 WMVJU9 Outdoor Unit RXL18WMVJU9 Casing Color Ivory White Heat Fin Spec/ Tube Waffle Fin (PE) / cp 7 Hi-XSL Tube Exchanger Fan Motor Motor Output HP 0.16 Compressor Type Hermetically Sealed Swing Type Model 2YC63AAXD Refrigerant Type FVC5OK Oil Charge oz (L) 30.43 (0.900) Refrigerant Type R-410A Charge lbs (kg) 3.53 (1.60) Airflow Rate cfm 2,419 (68.5) 2,362 (66.9) (m3/min) Fan Type Propeller Running Current (Rated) A 8.10 - 7.33 9.81 - 8.88 Power Consumption (Rated) W 1,629 - 1,629 1,979 - 1,979 Power Factor (Rated) % 96.7 - 96.6 97.0 - 96.9 Dimensions (H x W x D) in. (mm) 28-15/16 x 34-1/4 x 12-5/8 (735 x 870 x 320) Weight (Mass) lbs (kg) 132 (60) Sound Pressure Level dB(A) 54 55 Conditions Indoor 80.0°FDB (26.7°CDB) 70.0°FDB (21.1°CDB) Based /67.0°FWB 19.4°CWB) /60.0°FWB 15.6°CWB) on Outdoor 95.0°FDB (35.0°CDB) 47.0°FDB (8.3°CDB) / /75.0°FWB 24.0°CWB) 43.0°FWB (6.1°CWB) Piping Length 25 ft (7.5 m) Daikin Comfort Technologies North America,Inc 19001 Kermier Rd Waller TX 77484 Daikin City Generated Submittal Data www.daikincomfort.com or www.daikinac.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications,and information in this data sheet without notice and without incurring any obligations) FDMQ18/24WVJU9 30-m 3/117hole 121=IEEBEI Inspection port 2 Notu)I.louatimr of BwAacturer'a(abel:Surface of a control boo Control box (m4.•) 5-1/4(134) I 5Y4-18/16(63D) �' 0 17-11/18(450) 2.8de sure to aourrt the air filter inside the air Weep m the suction side. CASE 1) (All word) _69. ran; bolt poMeon) I or mare 8alect Clot Collation Eff ioienw Drain pan removal \(Brvieetr io ithodM6 N m ore."r_r mtd port expharme. t If 1M L strengteraturehen end hestdity In the mil ins Is the ad to mud i l F(30nice C) I a ytl - and vials such as le Mat i or union ie soa that the additional inwlnian I Ir IBf for there i6 a aDew aeuriala alch u I11 wool or wlYathYlaa then S • for service work under ha.Mohne n of 3//8 ft0)or alms. _ the unit,inspeot(on ADD rot pot thiup that should not gat wet under the indoor unit • port 2 it 1lmecesserV. Dana my dim when laniditr ruches over Kt a--- c-a _C C I I ' a drain pta Mick or air fl Item ere not clam 7 ( I 9 e w. ®, 98-OS/16We 6.tau for Service Vorkc (rnwaticn part/ Fit.A \own 11 R " I (mAnn Preside mules meow for mules work each as cheek emeetYDeml t m _g �__ ® �' (Al around) and asireeeaar of the control bar I _, and drain am Mar of the ton Mire were. x orYtn•x -1t 1 I Air "x ® I ' DIrrwcticn port l and 2D7-11/18 x17-11/18)(4Wx/�O11.A-1) - outlet § --- `� and a maw of ll-13/16(38W or more alder the mit fide) _- Control box Air Note)Inmectim port 2 Is not needed*hen there is a sww inlet for urviw monk Mr the unit. ® I �� 2)irrwcttm port 1(17-11/ior 17-11/1r the x41i0)on the control a �: Unit base • t23/18w 1M box side.end Inspection port 2 under the unit(Via B-1) i 0 ®' 1.,,g. (Bx 12) 3)Iapectiw port 3 under the unit end control box,(Vier 13-2) a �`.: a 0MIe •Provide Air 1! Air 0 I .. 'i sgmt the drainwen end controlhoc outlet "" Inlet s •Check the drains of optional aswsaor is when pondrt` inception pert 2■ -- �' • 1 r t1-tt 6 animal meseaiee such u filter thither and luidlfier S4nr°,.�.:. bon Fit.A-1 ter ex"-I in b S 11 1 I = mmewiw wit 1 x -i1 a a • o�__`T _ L. �trlvlexm1V18) g$ eve -1 1 �il-_II�"' 4�x.. \�� b eW�11,13/16 li - -- y=—. — c e�j 6amsas Mbdoo _ r:`6 rII- _�e ark Po or man) �� Ai ! TH Ibox i1 , '� 1 i brpeotton port 1 o„eol Bel b b b i'I',X $ I. )I _ 17-11/18 U5O)or more -1 nekbmme V ". ' 2 r / \ w leave . �_" Vie w 91 Drain Ii: n „riii2 ce Z (Fr®the Mr outlet) kepsmion QB -t,;�I boo I Vie.B-2 I b�y 1,4- check hole - g 11-13/le ki a (3a) ,:: T'-- I tt-t 3/fe 16-6/8 1hLlex t/2 Vide B-1Ma b 11 I I © 0 0 ,B k. " 46e (8z 12) FLW018.18 Fi111)24 ayb (`�( 'D a x„ !.g=7�l� a -- ahlo Fd1180,60 FpM71 S kb �w- y _ 7r. 0 7 D Bain ire wlsdimDaerar) 66 e1(1m km Dammini I i 1i 1 Atr inlet m r°�� �si�33itii�i Orlin motaaW asii(1mmFkalw a Air a - i$ l 9e/1e 1 4 (Note.2)— S .� 1 Alr.fi. term Air Qerirp Flap outlet =. ]�. 9 r-vte "$ .a p =MIME 0Ade wit Presanotim o . k 1 e 8 (110) J-15/16(60) ;9!g ilia g e e �p3 worts petrol Min anweiim n 31-1/2(800) 6 11 e 1 8 a b m a!, Carol run(hide) S Band Mimi(tweed In dtrul der)6( 10 /////�////////// $ / loin piernm1iw 0.8ehV4(131 «V Coipre Yl p.seetim Clerwucin) el/2412A I es/BNB.W tuorsurf De////////7// (From the Air inlet) uyiddwawertim(flnawmlad 01A(140 (DM PMIel1E NW Outdoor Unit - RXL09/12WMVJU9 MINIMUM SPACE FOR AIR PASSAGE WALL FEIGHT ON AIR CUTLET SIDE =LESS THAN 47-1/4 (1200) 4-HOLES FOR FOUNDATION BOLTS 5/16 OR 3/8(M8 OR MIS) ������ 7 wiiioniiiiiioi/iiiii// _irvuuirii�iviiuiiiiiii 7 /i v i/,,/nz M 18-1/2(470) 3-13/16(97) S $ P i a FS 1_75/18(50) 1-15i 16 5� j % n t ///Jiii✓Mimi./////.'Jii/i_ .,////,'.ii4,,,,, 11-3/18 284 9/16(15) BRAND NAME LABEL n MANUFACTURE'S LIQUID STOP VALVE 5/18 8 1/2 12.4 - 26-9/16(675) f 1-15/16(50) LABEL GROUND ..1/4 ....4 Cut ir -. • I , - I 1 .�'- . 13/ OUTDOOR AIR THERMISTOR �Y • _ n RHANDLE / I T,i1 'I I - m _ SERVICE _ m AO I STOP VALVE COVER / 6-1/4 159) 20 GAS STOP VALVE ('.3/8('.'5 Cut) .A r• p IN CASE OF REMOVING + STOP VALVE COVER AND +`` \ '^C _ PROTECTION PLATE ' 1 (�i 1 1 i n �I C iryt:�� l in�a m *A.*B DRAIN OUTLET =L— tr=4al').BIM WHEN CONDUCTING CONCENTRATED DRAIN 5/8(EI DRAIN PIPING WORK. ATTACH THE (IT b JOINT HOSE FOR CONNECTIONIWO SUPPLIED DRAIN CAPS. WITH DRAIN JOINT) RXL-W Series EDUS092213A • - 11. Electric Characteristics Power Supply Compressor OFM IFM Indoor Unit Outdoor Unit Hz-Volts Voltage Range MCA MFA RLA Hp W FLA Hp W FLA FTX09WMVJU9 RXL09WMVJU9 60 Hz-208 V Max.60 Hz,253 V 8.7 15 8.5 0.03 23 0.19 0.03 21 0.20 60 Hz-230 V Min.60 Hz,187 V FTX12WMVJU9 RXL12WMVJU9 60 Hz-208 V Max.60 Hz,253 V 12.2 15 12.0 0.04 27 0.21 0.04 28 0.23 60 Hz-230 V Min.60 Hz,187 V FTX15WMVJU9 RXL15WMVJU9 60 Hz-208 V Max.60 Hz,253 V 12.2 15 12.0 0.12 93 0.58 0.05 33 0.23 60 Hz-230 V Min.60 Hz,187 V FTXI8WVJU9 RXL18WMVJU9 60 Hz-208 V Max.60 Hz,253 V 18.6 20 18.3 0.16 122 0.77 0.07 48 0.37 60 Hz-230 V Min.60 Hz,187 V FTX24WVJU9 RXL24WMVJU9 60 Hz-208 V Max.60 Hz,253 V 18.8 20 18.3 0.16 122 0.77 0.07 48 0.57 60 Hz-230 V Min.60 Hz,187 V FVXS09WVJU9 RXL09WMVJU9 60 Hz-208 V Max.60 Hz,253 V 8.7 15 8.5 0.03 23 0.19 0.02 12 0.21 60 Hz-230 V Min.60 Hz,187 V FVXS12WVJU9 RXL12WMVJU9 60 Hz-208 V Max.60 Hz,253 V 12.2 15 12.0 0.04 27 0.21 0.02 13 0.22 60 Hz-230 V Min.60 Hz,187 V FVXS15WVJU9 RXL15WMVJU9 60 Hz-208 V Max.60 Hz,253 V 12.3 15 12.0 0.12 93 0.58 0.03 23 0.29 60 Hz-230 V Min.60 Hz,187 V FDMQ12WVJU9 RXL12WMVJU9 60 Hz-208 V Max.60 Hz,253 V 12.6 15 12.0 0.04 27 0.21 0.17 130 0.63 60 Hz-230 V Min.60 Hz,187 V FDMQ18WVJU9 RXL18WMVJU9 60 Hz-208 V Max.60 Hz,253 V 19.1 20 18.3 0.16 122 0.77 0.31 230 0.84 60Hz-230V Min.60Hz,187V FDMQ24WVJU9 RXL24WMVJU9 60 Hz-208 V Max.60 Hz,253 V 19.3 20 18.3 0.16 122 0.77 0.31 230 1.10 60 Hz-230 V Min.60 Hz,187 V Symbols: Notes: MCA :Min.circuit amps (A) 1. RLA is the max current that comes in cooling operation and heating operation. MFA :Max.fuse amps (A) 2. Maximum allowable voltage variation between phases is 2%. RLA :Rated load amps (A) 3. Select wire size based on the larger value of MCA. OFM :Outdoor fan motor IFM :Indoor fan motor FLA :Full load amps (A) W/Hp :Fan motor rated output (W, Hp) C:3D143137 C:3D143133A 69