Permit (16) CITY OF TIGARD COMMUNITY DEVELOPMENT MECHANICAL PERMIT '"`, Permit#: MEC2023-00693 ' Date Issued: 9/12/2023 T IGA1 D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S135BC01100 Jurisdiction: Tigard Site address: 11125 SW GREENBURG RD Project: PDX Estate Marketplace Subdivision: None Lot: None Project Description: Demo and rework gas lines to accommodate existing RTUs for TI. Contractor: OREGON HEATING&AIR CONDITIONING LLC Owner: GREENBURG SPACE CENTER LLC 6950 SW 111TH AVE 4804 NW BETHANY BLVD STE 1-2#243 BEAVERTON,OR 97008 PORTLAND, OR 97229 PHONE: 503-691-9699 PHONE: FAX: 503-691-8556 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 09/12/2023 $497.57 Class of Work: ALT Type of Const: VB Plan Review 09/12/2023 $124.39 12%State Surcharge-Mechanical 09/12/2023 $59.71 Occupancy Grp: B Occupancy Load: Info Process/Archiving-Sm$0.50(up to 09/12/2023 $0.50 Stories: 11x17) Project Valuation: $15,900.00 Fuel Air Handlers Fuel Types: Natural Gas Units< 10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $682.17 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: 3 Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules Issued By: Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit ApplicatioRECEIVE City of Tigard Date/B d 1'i,i I V(/(/\ �n Permit No.: V 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review _ Phone: 503.718.2439 Fax: 503.598.1960LIG t L023 Date/By: •a,,,,_______a�3 Other Permit: T i Ci A R I) Inspection Line: 503.639.4175 Date Ready/By: j Juris: la See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method4;i,/ Q3 jp /� Supplemental Information BUILDING DIVISION I •�/a gG� t f tr i'-•S ('� r OF WORK COMMERCIAL FEE* SCh EDULE—USE C7CL i' i'/ it,- TYPEy�C Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ 15,900.00 CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ❑ 1-and 2-family dwelling ®Commercial/industrial 0 Accessory building For special information use checklist ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address:11125 SW Greenburg Rd Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Tigard, OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name: PDX Estate Sales TI Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision: Lot no.: Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas I fireplace 23.32 Inst Log lighter(gas) 23.32 Wood/pellet stove 33.39 Demo and rework gas lines to accommodate roof top units Wood fireplace/insert 23.32 and new gas meter. Chimney/liner/flue/vent 23.32 Other: 23.32 0 PROPERTY OWNER 1 0 TENANT Environmental exhaust and ventilation: Name: C1 r% 0'6 5 �� L'„C Range hood/other kitchen •,J equipment 33.39 Address:,i%04 \ rki Uci�1 ..1-1. Clothes dryer exhaust 33.39 City/State/ZIP:Tex I ci l Single-duct exhaust(bathrooms, UU toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 0 APPLICANT 0 CONTACT PERSON ': Other: 23.32 Fuel piping: Business name: Oregon Heating and Air Conditioning $14.15 for first four;$4.03 for each additional Contact name: Furnace,etc. Address: 6950 SW 111th Ave Gas heat pump Wall/suspended/unit heater City/State/ZIP: Beaverton OR 97008 Water heater Phone:(503) 691-9699 Fax::( ) Fireplace Range E-mail: permits@oregonheating.com Barbecue CONTRACTOR Clothes dryer(gas) Business name: Other: regon Heating and Air Conditioning MECHANICAL PERMIT I EES* Address: y960 SW 111th Ave Subtotal City/State/ZIP: Beaverton OR 97008 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(503) 691-9699 Fax:( ) State surcharge(12%of permit fee) CCB lic.: 137653 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 ,A- / days after it has been accepted as complete. Authorized signature: 4 yy y_j�-K�,�B11-ta * Fee methodology set by Tri-County Building Industry Service Board Print name: Amy McDonald U.4 Date:08/17/2023 1:\Building\Permits\MEC_PermitApp_040113.doc 440-4617T(11/02/COM/WEB) p4 NW Natu ra I` Fax completed orders to 503-721-2547 or e-mail to commercial@nwnatural.com COMMERCIAL APPLICATION Site plans must be submitted with application. This service installation is governed by the terms in NW Natural's Tariff,available at www.nwnatural.cam. Submitted Date: E-Mail Address: (for Order Confirmation) NW Natural Contact: APPLICANT TYPE ❑ New Service Line&Meter 8 New Additional Meter Only ❑ Meter Re-Installation No current gas service line to structure New meter on existing manifold Replacement meter only on existing riser or manifold Green-Tagged 0 ID-Tagged ❑ Any New Housepipe? Address of primary meter: ❑Yes ❑No Job Site Address: 11125 SW Greenburg Rd City: Tigard State: OR Project Name: PDX Estate Marketplace Cross Street: SW Tiedeman Ave APPLICANT INFORMATION Applicant must also complete a Business Credit Application. Responsible Billing Account Holder: Greenburg Space Center, LLC Contact Person:Christin Osborne,Kidder Mathews(Property Manager) Phone: (503)721-2716 Email:christin.osborne@kidder.com Mailing Address: do Kidder Mathews 101 SW Main St,Ste 1200 City: Portland State: OR Zip: 97204 CONTRACTOR INFORMATION Gen Contractor: Robinson Construction Co. Email:ryanrob503@gmail.com Phone: (503)209-8545 Site Supervisor: Ryan Robinson Email:ryanrob503@gmail.com Phone: (503)209-8545 Project Mgr: Ryan Robinson Email:ryanrob503@gmail.com Phone: (503)209-8545 Mech Contractor: Oregon Heating&Air Conditioning Email:tleathers@oregonheating.com Phone: (503)691-9699 Architect/Engineer: Email: Phone: STRUCTURE & EQUIPMENT INFORMATION 0 New Construction(or previously unoccupied space) Square Footage(to be served by this meter):19,619 SF NW Natural yellow conduit required.# Project Type Primary Business Use:Warehouse/Retail (select one) 0 Conversion(previously occupied,no previous gas service) (i.e.Multi-family,Warehouse,Office,Retail,Restaurant) 8 Existing(previously occupied and previous gas service) Number of Units: 4 Meter Pressure: 8 2 PSI 0 5 PSI(Requires NW Natural Approval) New Construction ready date: 8/23/2023 Meter Location: Existing manifold at south east corner of building south of electrical room Distance in feet from Street to Meter: 65 feet Will dryout heat be required? ❑Yes 8 No If Yes,total dryout load: Type Please describe equipment Quantity BTU/Hour BTU/Hour (per ea.unit) Total Space Heating Carrier,Model 48TCED14E3A6 3 184,000 552,000 Water Heating Electric water heater Cooking N/A Other Space Heating: Carrier,Model 48TCEA06A2A6 1 93,000 93,000 Other Space Heating: Carrier,Model 48ES-A240603 1 48,000 48,000 TOTAL 693,000 F-8006 NS Commercial Application OR and WA Form Updated 3/13/2018 ire on RECEIVED AUG 2 1 2023 Heating&Air Conditioning CITY OF TIGARD BUILDING DIVISION PDX Estate Sales 11125 SW Greenburg Rd. Tigard, OR 97223 Scope of Work Oregon Heating and Air Conditioning will perform the following scope of work: 1. Rework existing gas lines. Mechanical General Notes: 1. Cooling equipment does not exceed the load of the calculated requirement. 2. All steel ducting will be 26 ga minimum galvanized. Flex per Mfg. 3. Heating and cooling ducting to be designed to not exceed 0.5 wc positive(supply)and 0.5 wc negative (return). 4. Provide programmable thermostat. 5 degree deadband minimum. 7 day. Microprocessor. Set program for night energy savings. 5. Seal ducting with UL listed mastic or mastic tape. 6. Fan motor does not exceed allowable,first available above BHP. 7. Max leakage rate of OSA or exhaust dampers to be 4 cfm/sft @ 1.0 sp. 8. Provide 0 and M to building owner. Ml OHAC CCB # 137653 PHONE NUMBER OPERATIONS CONTRACTOR LICENSE 503-691-9699 6950 SW 111th Ave Oregon CCB 137653 Beaverton,OR 97008 WA OREGOHC85102