EconAir's ETL Listed ESX-2 exhaust only hood efficiently meets
the challenges of low ceiling cooking applications.
Features at a Glance
• ETL Listed and ETL Sanitation Listed Product
• Superior Exhaust Flow Rates
• Exceptional Capture and Containment of Cooking Vapors
• Wall or Back-to-Back Island Configurations
• Front Design Directs Air into Filters
• Stainless Steel Construction
• Double Wall, Insulated Front
• Heavy Duty Stainless Steel Grease Baffle Filters
• Grease Drain System
• Pre-punched Hanging Angles
• Factory Pre-wired Lighting
Optional Equipment
• Utility Cabinet
• Fire Suppression System
• Electrical Controls
• Front Perforated Supply Plenum with Supply Volume Damper Assembly
• Integral Clearance to Combustibles System
• Enclosure Panels to Ceiling
• End Panels
• Type 304 Stainless Steel Construction
- Exposed Surfaces Only
- 100% Construction
• Lighting
- Recessed Incandescent
_ - Recessed Fluorescent
- Compact Fluorescent
- LED
- Recessed LED
- Halogen
• Roof Top Package
• Separate Exhaust and/or Make-Up Air Fans
• Heated Make-Up Air Units
- Direct Gas Fired Heated Make-Up Air Fans
- Indirect Gas Fired Heated Make-Up Air Units
- Electric Heated Make-Up Air Fans
- S/S Wall Panels
• Face Mounted Controls
Stainless Steel Baffle Type Filters
- High Efficiency Filters
- Captrate Combo, - Solo Filters
Performance Data
Avg Cooking Confi uration Min Exhaust Recommended
Surface Temp (°F) - Cooking Surface g CFM/ft Duct Sizing
450°F Single Wall Hood 228 Exhaust
- Ovens, Steamers, Kettles, Open-Burner Based on 1500
2 Wall Hoods Back-to-Back in an 456
- Ranges, Griddles, Fryers FPM
island configuration
Single Wall Hood 294
600°F
Gas Charbroilers, Electric Charbroilers 2 Wall Hoods Back-to-Back in an 588
island configuration
ESX-2 Specifications
Description The model ESX-2 is a Type I, single-island, exhaust canopy used for collection and removal of grease-
laden vapors and smoke over all types of restaurant equipment.
Application The hood shall provide flexibility in designing kitchen ventilation equipment and shall be tested and listed
for use over 400°F light/medium duty cooking surfaces; 600°F heavy duty cooking surfaces; and up to 700°F extra
heavy duty cooking surfaces.
Construction The hood shall be constructed of type 430 stainless steel with #3 or #4 polish where exposed. All seams
shall be welded or in conformance with UL 710 standards. Unexposed surfaces shall be constructed of aluminized
steel. Individual component construction shall be determined by manufacturer and ETL. Construction shall be
dependent on the structural application to minimize distortion and other defects. All seams, joints and penetrations of
the hood where grease-laden vapors and exhaust gases are present must be liquid-tight, continuous welds in
accordance with NFPA 96.
The hood shall be constructed to include:
• A double wall insulated front to eliminate condensation and increase rigidity. The insulation shall have a flexural
modulus of 475 EI, meet UL 181 requirements and be in accordance with NFPA 90A and 90B.
• An integral front baffle to direct grease laden vapors toward the exhaust filter bank.
• An integral grease drain system on the hood back with a minimum 1/8" per foot slope, to include an exposed,
removable 1/2 pint grease cup to facilitate cleaning.
• A built-in wiring chase for electrical controls on the front face of the hood designed to avoid penetration of the
capture area and eliminate the need for an external chaseway.
• UL incandescent light fixtures and globes, allowing up to a 100 watt standard light bulb, installed and pre-wired to a
junction box and installed with a maximum of 3'-6" spacing on center.
• Exhaust duct collar 4" high with 1"flange.
• A minimum of four connections for hanger rods. Connectors shall have 9/16" holes pre-punched in 1 1/2"x 1 1/2"
angle iron at the factory to allow for hanger rod connection by others.
• UL Classified aluminum baffle filters, with size and quantity determined by the hood's dimensional parameters, but
extending the full length of the hood with filler panels not to exceed 6".
- Certifications The hood shall be ETL Listed, comply with UL 710 Standards and shall be built in accordance with
- NFPA96. Hood shall be tested for compliance with the ETL Sanitation Mark.
-Documentation Manufacturer shall furnish complete computer generated submittal drawings including hood section
view(s), plan view(s), duct sizing, and CFM and static pressure requirements. Static pressure, air velocity and air
volume requirements indicated on drawings shall be precise and accurate and hood shall perform to said
specifications. Drawings shall be available to the engineer, architect and owner for their use in construction, operation
and maintenance.
Sectional View
irtci9.�.xr�ce-�_ Rr!
tiTtf
INK clei,lrarcA xr i "rax-.e
APf
Products> Make-Up Air> Rooftop Filtered> SA
SA
FkIkre
MODULAR ROOFTOP FILTERED MAKE-UP AIR FANS
Air Volume: 2—22,000 cfm
Maximum SP: 4"wg.@ standard air density
The Air Handler Unit is the heart of the modular fan system.It is designed to deliver fresh outside make up air for installations requiring frequent air
changes.Units are designed for indoor or outdoor applications,and are available in vertical or horizontal discharge configurations.
Packages are available in sizes up to 22,000 CFM,and external static pressures up to 4"W.G.Units have large doors on both sides to provide ample
access to all internal components.Standard features include vibration isolation,high efficiency motors,and adjustable drive sheaves(belt drive units
only).Units consist of a galvanized enclosure with a blower and motor.Belt drive units also include pulleys and belt(s).The blower module has a standard
horizontal inlet designed to accommodate an outside air inlet hood with a standard 2"filters and screen.
To satisfy a variety of installation and climatic requirements,packages are available in a number of configurations.Possible configurations include the
addition of either a v-bank or an evaporative cooler intake module and a direct fired or indirect fired heating module.All modules bolt together to form a
rigid common base structure that mount onto a single curb structure or can be hung for indoor applications.
Combination packages that include both exhaust and supply fans mounted on a single roof curb are also available,please contact your sales
representative for more information.
FEATURES&BENEFITS
L Vibration isolation.
High efficiency motors.
Compact weatherproof design.
LI Adjustable drive sheaves.(belt drive units only)
Horizontal or down discharge.
2"washable filters.
Inlet screen.
LjG G90 galvanized steel.
Li Easy accessibility to all components for inspection,maintenance and cleaning.
Disconnect switch.
o Lifting points.
u Speed control standard on direct drive units.
OPTIONS
w Gravity intake damper.
Li Motorized intake damper.
o Roof Curbs.
tm Wall Mount Kit.
o Mixing Box with Damper Control.
Li DX Cooling Coils.
:y Hot Water/Steam Coils.
go-; Indoor Hanging Cradle.
Insulated Housing.
o Evaporative Cooler Intake.
VAV Packages. '
o Extra Set of V-Belts. (belt drive units only)
CERTIFICATIONS
The SA Model has been certified by ITS.This certification mark indicates that the product has been tested to and has met the
minimum requirements of a widely recognized(consensus)U.S.products safety standard,that the manufacturing site has been
audited,and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance. C(610.0)US
Model SA is ETL Listed under file number J20029811-001 and complies with UL705 and CSA C22.2,No. 113 Standards.
1
1/21/2021 DU-HFA-Centrifugal Upblast Direct Drive Fans by CaptiveAire
DU-HFA
CENTRIFUGAL UPBLAST DIRECT DRIVE FANS
. ,
r yr
/
ff-
eff-
� P
s
R ' 4
€a Air Volume: 2—22,500 cfm
o Maximum SP: 4"wg.@ standard air density
FEATURES&BENEFITS
a Completely enclosed drive compartment protects motor from airborne contaminants
o Forced fresh air through the motor compartment cools motor and ensures long motor life
o Variable Speed Control on Single Phase Units Only.(VFDs required to adjust speed for 3 phase versions)
n Non-overloading backward inclined wheels,blades and inlets fabricated from aluminum
a Units up to 24"nominal wheel can be wall mounted
o Quick release latches allow for easy access to motor compartment.(Size 12&larger)
B Standard emergency disconnect switch(Size 12&larger)
OPTIONS
Gravity Damper.(UL705 Only)
e Motorized Damper.(UL705 Only)
o Wall Mount Sleeve.
c Roof Curb.(Vented and Non-Vented)
o Grease Collection Box.(Size 12&larger)
ra Bird Screen.(UL705 Only)
Base Hinging Kit or Hinged Sub Base.(for NFPA96 compliance)
c Combination package that includes a supply fan mounted on the same roof curb.
CERTIFICATIONS
CaptiveAire certifies that Model DU1 OHFA thru DU360HFA shown herein are licensed to bear the AMCA seal.The
ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication aatxa44,
311,and comply with the requirements of the AMCA Certified Rating Program.
am I C US
Models DUIOHFA thru DU360HFA are ETL Listed under file number 102628244PRT-001 and comply with UL705
sawsisw
(electrical)Standards and CSA Std C22.2,No 113.
https://www.captiveaire.com/catalog/fanCatalog.asp?catid=105 1/2
1/21/2021 DU-HFA-Centrifugal Upblast Direct Drive Fans by CaptiveAire
•Models DU12HFA thru DU360HFA are ETL Listed under file number 103336443COL-001 and comply with UL762 and
ULC-S645 Standards.
Catalog#110C
October 2020
https://www.captiveaire.com/catalog/fanCatalog.asp?catid=105 2/2
DU .)J J_,ti1
SERIES UPBLAST EXHAUST FANS (UL762) FEATURES: DmiliiiirWLlior
_,;. 11,z.,,,
-DIRECT DRIVE CONSTRUCT ON I NO BELTS+PULLEYS) D
'Of -ROOF MOUNTED FANS RESTAURANT MODEL-UL705&UL762&ULC-5645
-VARIABLE SPEED CONTROL
VENTED
INTERNAL WIRING Y CURB
-'Of EATHER.PROOF DISCONNECT
-THERMAL OVERLOAD PROTECT ON(SINGLE PHASE)
-HIGH HEAT OPERATION 300'F f1499'C1 E /} ►�
y1;1
n GREASE CLASSIFICATION TESTINGlilt bS/J
NORMAL TEMPERATURE TEST .41# 20 GAUGE
1 IL --Tit- EXHAUST FAN MUST OPERATE CONTINUOUSLY STEEL
HT
�r F WHILE EXHAUSTING AIR.AT 300'F i 149'CI CONSTRUCTION
UNTIL ALL FAN PARTS HAVE RFAf HED
T'H ERMAL EGU ILI BRI UM.AN D'Or ITH OUT ANY
r DETERIORATING EFFECTS TO THE FAN WHICH 3'FLANGE
GREASE DR,alh!
II IV 1(» I
WOULD CAUSE UNSAFE OPERATION. �' ��
ABNORMAL FLARE-UP TEST / �
EXHAUST FAN MUST OPERATE CONTINUOUSLY ''''
/
B WHILE EXHAUSTING BURNING GREASE VAPORS / O DIO F OPENING
1 AT 600 1316'C1 FOR A PERIOD OF
15 MINUTES',ATH OUT THE FAN BECOMING RO
DAMAGED TO ANY EXTENT THAT COULD CAUSE
R' 'F AN UN SAFECONDIIION.
2G
OPTIONS: `,,"-'
G=P.i 3' PITCHED CURBS ARE AVAILABLE 7
GREASE BOX FOR PITCHED ROOFS.
HINGED FAN 30'
RO PITCHED CURB
7+ f/\ ^`, „ INSULATED CURB SPECIFY PITCH: 12
r LOWPROFILE OPTION EXAMPLE:7J12 PITCH=30'SLOPE
C DUCTVfOP,K BETWEEN
EXHAUST RISER ON HOOD NOTES:•'LOW PROF!LE'HT DIMENSION CHANGES.
DU DIRECT DRIVE AND FAN BY OTThiERSI
CENTRIFUGAL UP-BLAST EXHAUST FANS DIMENSIONAL DATA CURB DIMENSIONAL DATA
FAN MODEL HT "HT VI B C F R, RO WEIGHT LB FAN MODEL D E
DU12 18 17 22 2 19 141/2 10 5/8 17 40 0U12 1 71/2 26
DU30 251/4 20114 251/2 2 21 181/2 121/8 19 50 DU30 19112 22
DU33 25114 20114 25112 2 21 18112 12118 19 50 DU33 19112 22
DU50 271/4 23114 28 718 2 21 21 1/2 13114 19 55 DU50 191/2 20
DLI85 301/2 251/2 31 7/8 2 24 3/4 23 14 718 22112 60 DU85 23 20
DU180 333/4 N/A 393/8 2 28 225/8 161/2 26 190 ❑U180 261/2 20
DU200 33 318 N/A 38 718 2 28 29112 18 26 195 DU200 26 1/2 20
DU240 37112 N/A 43 3/8 2 33 30 58 23 718 31 270 DU240 31 112 20
0U300 44 N/A 523/4 2 40 331/2 24 38 410 DU300 33 1/2 20
DU360 499/16 NJA 635/16 2 44 437/16 30 42 470 DU360 421/2 20
t
r
Factory Built Double Wall Grease Duct Specification
Furnish double wall, factory built grease duct for use with Type I kitchen hoods, which conforms to the
requirements of NFPA-96. Products shall be ETL listed to UL-1978 and UL-2221 for venting air and grease vapors
from commercial cooking operation. Models DW-2R, 3R and 3Z are used for grease duct applications when
installed in accordance with these instructions and National Fire Protection Association "NFPA 96"; Standard for
Ventilation Control and Fire Protection of Commercial Cooking Operations. Double wall grease ducts are
listed for a continuous internal temperature of 500 degrees F and intermittent temperatures of 2000 degrees F.
The duct sections shall be constructed of an inner duct wall and an outer wall with insulation in between. The inner
duct wall shall be constructed of .036 inch-thick, 430 type stainless steel and be available in diameters 5" through
36". The outer wall shall be constructed of stainless steel at a minimum of .024 inch-thickness. The duct, based on
model number, shall include layers of Super Wool 607 Plus, Insulfrax Elite Blanket insulation, or Unifrax S16 Bulk
Fiber insulation between the inner and outer wall. Grease duct joints shall be held together by means of formed V
clamps and sealed with 3M Fire Barrier 2000+. The duct wall assembly shall be tested and listed at 3/4", 1" or
zero-inch clearance, according to classifications.
Classifications and Clearances
UL 2221: Standard for Fire Resistive Grease Duct Enclosure Assemblies. Chapter 7 of this standard references a
test labeled Internal Fire Test. Section 7.1.1 references two installation conditions, Condition A and Condition B.
Condition A represents all installation condition except for installation within non-ventilated combustible
enclosures. Condition B represents installation within a non-ventilated combustible enclosure.
Model DW-3Z is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr.
fire resistive shaft enclosures with a minimum zero clearance to combustibles (sizes 5"to 36" diameter). Model 3Z
is listed in accordance with the requirements for duct enclosure Condition A and B.
Model DW-3R is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr.
fire resistive shaft enclosures with a reduced clearance to combustibles (sizes 5" to 24" diameter). Model 3R is
listed in accordance with the requirements for duct enclosure Condition B.
Model DW-2R is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr.
fire resistive shaft enclosures with a reduced clearance to combustibles (sizes 5" to 18" diameter). Model 2R is
listed in accordance with the requirements for duct enclosure Condition B.
DUCT MODEL INNER DIAMETER OUTSIDE CLEARANCE TO CLEARANCE TO
(ID) DIAMETER COMBUSTIBLES NON-COMBUSTIBLES
DW-2R 5"- 16" ID +4 3/4"(1) 0"
18" ID + 4 1"(2) 0"
DW-3R 5"-24" ID + 6 3/4"(3) 0"
DW-3Z 5" - 36" ID + 6 0"(4) 0"
(1) DW - 2R: 3/4" clearance to combustibles from the surface of the duct outer shell; zero inch
clearance from combustibles from the tip of the outer V Band.
(2) DW - 2R: 1" clearance to combustibles from the surface of the duct outer shell; zero inch
clearance from combustibles from the tip of the outer V-band.
11110
(3) DW - 3R: 3/4" clearance to combustibles from the surface of the duct outer shell; zero inch
clearance from combustibles from the tip of the outer V Band.
(4) DW - 3Z: 0" clearance to combustibles from the surface of the duct outer shell.
�' fix 4 '-2 ---� . ,, -
6 3
dui Q sa: ��a � •
Classifications and Clearances
Through floor fire stop support assembly are used to support duct sections that penetrate a fire-resistant floor(s).
The full support ring is installed under the double V band; the struts are connected to the support ring with
supplied 5/16"-18 hardware. Once the struts have been connected, they are secured to the floor using appropriate
type and size fasteners supplied by others. When duct systems penetrate a fire resistance rated floor, ceiling and/
or a wall, a fire stop kit is used to retain the fire resistance rating on the floor and/or wall. The double wall grease
duct (2R, 3R and 3Z) and the fire stop assemblies detailed below have achieved 2-hour ratings for integrity,
insulation and stability. Testing was conducted in accordance with the applicable requirements UL 2221, Test of
Fire Resistive Grease Duct Enclosure Assemblies.
DUCT MODEL INNER OUTER DIAMETER ' SQUARE / ROUND
DIAMETER OPENING
MIN/MAX
DW - 2R 5" 9 11" 12"
DW - 2R ' 6" I 10" I 12" - 13"
DW - 2R I 7" I 11" I 13" - 14"
DW - 2R 8" 12" 14" - 15"
DW - 2R 10" 14" 16" - 17"
DW - 2R 12" 16" 18" - 19"
DW - 2R 14" 18" 20" - 21"
DW - 2R 16" 20" 22" - 23"
DW - 2R 18" 22" 24" - 25"
DW - 3R / 3Z 5" 11" 13"- 14"
DW - 3R/ 3Z 6" 12" 14"- 15"
DW - 3R/ 3Z 7" 13" 15" - 16"
DW - 3R/ 3Z 8" 14" 16" - 17"
DW - 3R/ 3Z 10" 16" 18" - 19"
DW - 3R/ 3Z 12" 18" 20" - 21" _
DW - 3R/ 3Z 14" 20" 22" - 23"
DW - 3R/ 3Z 16" 22" 24" - 25"
DW - 3R/ 3Z 18" 24" 26" - 27"
DW - 3R/ 3Z 20" 26" 28" - 29°'
DW - 3R/ 3Z 22" 28" I 30" — 31"
DW - 3R/ 3Z .24" 30" 32" - 33"
DW - 3Z 26" 32" 34" - 35"
DW - 3Z 28" 34" 36" - 37"
DW - 3Z 30" 36" 38" - 39"
DW - 3Z 32" 38" 40"- 41"
DW - 3Z 34" 40" 42"- 43"
DW - 3Z 36" 42" 44" - 45"
Double Wall Grease Duct shall be installed in accordance with the manufacturer's "Installation, Operation
and Maintenance Manual," ETL listing, state codes and local codes. Fans shall be supported independently from the
grease duct sections. Protect grease duct from twisting or movement caused by fan torque or vibration.
Certifications
_ _ The DW Series has been certified by ITS. This certification mark indicates that the product has been tested to and
,4.^ has met the minimum requirements of a widely recognized (consensus) U.S. and Canadian products safety
standard, that the manufacturing site has been audited, and that the applicant has agreed to a Pp g program of
periodic factory follow-up inspections to verify continued performance.
Models DW-2R and DW-3R are ETL Listed under file number 1000082319SAT-006 EEV and comply with UL1978
and UL2221 Standards.
Model DW-3Z is ETL Listed under file number 1000082319SAT-006 EEV and complies with UL1978, UL2221
and CAN/ULC-5144 Standards.
OE R7f4.
£ET95
mac �
•
,e ��Atir cueA
Additional Information Available
Operation,Installation, and Maintenance Manual
Copy of the manual is sent with every duct order from our manufacturing facility. Additional copies, if needed, are
available for download at:
httPs:/,'WWW.Captiveaire.cons/C,ATALOGCONTFNT/DUCTW'ORK/INSTALLAT ION.ASP'Catld-3(6&Model=GREASE+DU
• CT
Available also at the link above are recommendations for vertical and guy line support guides.
Grease Duct Design Guide
The Grease Duct Design Guide gives specifics for all parts available for order including Elbows, Straight Pieces,
etc. Formulas and other information to calculate static pressure through a pre-engineered system is also
available. Design Guide is available for download at hops://��ww cai�tsueaire comicatalc;eljoenpartCataloca asp?
catld=306 or as a hard copy from your local CaptiveAire sales office.
Sample Duct Drawing
(10)
2
9,�
_/
8
05004,4
o oa
00 ,0 ,
8 ,
8j f 8
1. Exhaust Fan 6. Duct Sensor
2. Adjustable Section-Terminates at transition 7. Riser Cover
plate. 8. Double V-band
3. Vertical Support- Installed under V-band. g. Roof
4. Standard Duct Length 10. Vented Curb
5. Exhaust Hood