Loading...
HomeMy WebLinkAboutPermit Support Document (2) FOR OFFICE USE ONLY—SITE ADDRESS: 1% 56 S W jC Xk mook,K S-t_ This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard ' COMMUNITY DEVELOPMENT DEPARTMENT 1 Transmittal Letter i !i, r, I) ' 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: `� DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED FROM: 'vfk ( s i, JUL 2 4 2023 COMPANY: JG,,1^/3 /C-vrU l J CITY OF TIGARD PHONE: C7 g) 5.77-�a.S— BUILDING DIVIS N EMAIL: �wa icer,r i/ Wert RE: 77 b ytinr/wz+ Oa (09 ti (Site Address) (Yermit Number) 1..o (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): ,5i ,,T,,L.r 6r.„1- r-e-d ! REMARKS: Routed to Permit Technician: Date: ` - ) - 2,3 Initials: Fees Du�J Yes No Fee Description: Amount Due: CAP;.es (t5) $ 1/' 2 p $,%Z.`�D $ 33 7S� Special Instructions: Reprint Permit(per PE): ❑ Yes NJ No ❑Done Applicant Notified: Date: K/t 113 Initials: I:\Building\Forms\TransmittalLetter-Revisions_073120.doc MEGZdZ1. 0G6gq 1850 Sw Dar-km au}hM. M1 MEAT LINEUP/ISLAND SINGLE DECK C Product/Parts Questions KYSOR WARREN KYSOR/WARREN CX1AG 0 0 Technical Service Support 1855.813.1461 4 m' Case Length(ft) General Case Data 4' 6' 8' 12' RECEIVED Total Display Area (ft2) 12.03 18.06 24.06 36.12 JUL 2 4 Cubic Capacity(ft3) 12.41 18.63 24.82 37.26 2023 Weight(lb) a- , s,8. .__ CITY OF TIGARD Refrigeration Setpoints(HFC&TCO2) . `'- ,--'----_BU1IING DIVISION 1 Evaporator Temperature(°F) 23 23 23 23 �� Superheat Setpoint(°F) 6-8 6-8 6-8 6-8 p ,s3'2.1 ` 6 U1 Refrigeration Setpoints(Glycol) _ sa Supply Temperature(°F) 20 20 20 20 164 Flow(GPM) QTE QTE QTE CITE Fluid% 35 35 35 35 ;:-L� ( 29 _ ii._ .. Pressure Drop(PSID) QTE QTE QTE QTE 29 Electrical Data(Amps) 115V/60Hz, 1 Phase 4'8 Fans(EC Motors) 0.07 0.14 0.14 0.22 REFRLGERAT,ON-- -, PIPSNG "! 2 _ELECTRICAL ACCESS ACCES il S _STUB l \r ,ci 5z Y UP ZP \ \\ Off Cycle Hotgas Hotgas ARE zA13°, ti Y s Defrost Data HFC TCO2 I ' T ° Defrosts per Day 6 6 6 1 Failsafe Duration (min)' 22 20 20 r Termination Temp(°F) 45 45 45 ,_ '"' STANDARDCATIONPRI LOCATION(PLATINUM:,OPLATE STANDARD KICK PLATE LOCATIO, Drip Time(min) 0 2 2 DRAIN CONNECTIUN FRJ dT FCASE S -- ---- , ((WITH P-TRAP RIGHT OR LEFT! (AXDDERN CLASStC;� — Pumpout Time (min) 0 0 10 --OP-NONA,—KICK PLATE LOCATION (PLATINUM Case Length(ft) Refrigeration Data (General) 4' 6' 8' 12' Discharge Air Velocity(fpm) 225-250 225-250 225-250 225-250 Fan Speed (rpm) 1000 1000 1000 1000 Discharge Air Temp(°F) 31 31 31 31 Conventional Thermal Load (Btuh) 1472 2208 2944 4416 Parallel Thermal Load (Btuh) 1398 2098 2797 4195 Additional Btuh per ft LED-Canopy/Shelf&Nose NA NA NA NA Refrigerant Charge (Ibs) 1.24 1.85 2.58 3.93 "1 At ASHRAE conditions.For conditions above 757,55%RH,increase defrost time by 15 min. Type I refrigerator,intended for use in an area where the environmental conditions are controlled and maintained that conditions do not exceed 75*F and 55%relative humidity.Heatcraft Worldwide Refrigeration,whose policy is one of continuous improvement,reserves the right to change at any time specifications,designs,or prices without incurring obligation," > i. g •,f%s. CIO . F D2 DELI LINEUP 2-TIER CASE Product/ Parts Questions iKvir KYSOR/WARREN CX2XG torso WARREN nical Service Support 0 �,,., 1 855.813.1461 Case Length(ft) General Case Data 4' 6' 8' 12' Total Display Area (ft2) 9.40 14.11 18.80 28.22 Cubic Capacity(ft3) 16.11 24.19 32.22 48.38 2 Max Shelf Depth Top/Bottom 18 18 18 18 L' > c ;; Weight(lb) - - - - ;� z3� sN a. ,. Refrigeration Setpoints(HFC) cn 18 I Evaporator Temperature(°F) 23 23 23 23 47 a 1 • Superheat Setpoint(°F) 6-8 6-8 6-8 6-8 , I� • 32 ._ 1 • Refrigeration Setpoints(Glycol) - Supply Temperature(°F) 20 20 20 20 k'. 164 ' , 27 Flow(GPM) QTE QTE QTE QTE Ij r" 1 to, 7 Fluid% 35 35 35 35 1 z Pressure Drop(PSID) QTE QTE QTE QTE 3 zs 35- '—8— .1 Electrical Data(Amps) _._......._._._.._42 115V/60Hz, 1 Phase 432 Fans(EC Motors) 0.10 0.19 0.19 0.38 Canopy LED Lighting per row 0.22 0.33 0.44 0.67 Shelf LED Lighting per row 0.08 0.10 0.15 0.23 REFRIGERATION-- 1?w PIPING 4 EL TRI AL ACCESS ACCESS AmNIMUM.A1R`SFROE Off Hotgas Hotgas zeu. .,:<.o /��./,':', 42 P 22�_%i /�i 'l� ' I Defrost Data Cycle HFC TCO2 2 ` Defrosts per Day 6 6 6 STUB =9" 1 1 aUUP A \ ' 7-9 I i t an' a's Failsafe Duration (min) 25 20 20 ` a t �y " r Termination Temp(°F) 47 47 47 ,'�� l � '� //,lei//a-?o,-4-ii! 4,...,,,,,,,,,,,,,,:,:.i':%G.�/,2 a-/i✓..f_l-. 1 Drip Time(min) 0 2 2 r Pumpout Time(min) 0 0 10 • -C I c_. STANDARD KICKPLATE I --AS YR YTY ttu _. LUCATKSN(PL6.TINEiM1h1 ?IF-ita:Ina-)fS. ORriIT!CONNECTION -_.__..... ........'( --STANDARD KICK PLATE LOCATION FRONTOF CASE (MODERN.CLASSIC) I WITH A-TRAP RIGHT OR LEFT) ---OPTIONAL KICK PLATE LOCATION (PLATINUM, Case Length(ft) Refrigeration Data (General) 4' 6' 8' 12' Discharge Air Velocity(fpm) 170-220 170-220 170-220 170-220 Fan Speed (rpm) 1100 1100 1100 1100 Discharge Air Temp(°F) 31 31 31 31 Conventional Thermal Load (Btuh)with one row of canopy LED 3496 5245 6993 10489 Parallel Thermal Load (Btuh)with one row of canopy LED 3206 4806 6411 9617 Additional Btuh per ft LED-Canopy/Shelf&Nose 13/11 13/11 13/11 13/11 Refrigerant Charge(lbs) 1.851 2.768 3.703 5.536 "1 At ASHRAE conditions.For conditions above 75°F,55%RH,increase defrost time by 15 min. Type I refrigerator,intended for use in an area where the environmental conditions are controlled and maintained that conditions do not exceed 75°F and 55%relative humidity. Heatcraft Worldwide Refrigeration,whose policy is one of continuous improvement,reserves the right to change at any time specifications,designs,or prices without incurring obligation." , 14 • , ` KYSOR WARREN ✓ Product/Parts Questions KYSOR WARREN EPTA US MX6LN 'Technical Service Support 1855.813.1461 _MALE Case Length (ft) General Case Data 4' 6' 8' 12' - 42 Total Display Area (ft2) 18.52 27.78 37.04 55.57 _ Cubic Capacity(ft3) 48.30 71.60 96.50 143.20 /,`, Max Shelf Depth [Top/Bottom] 24 24 24 24 j Weight(lb) - - - - ;, 24 Refrigeration Setpoints(HFC&TCO2) -,; 1 Evaporator Temperature(°F) 23 _ 23 23 23 ! 5 3 w 8 Superheat Setpoint(°F) 6-8 6-8 6-8 6-8 3 a 4 Refrigeration Setpoints(Glycol) ',.�- Supply Temperature(°F) 20 20 20 ' 20 :} Flow(GPM) 1.421 2.132 2.843 _ 4.265i /. --._...___._.._z......_.._ Fluid% 35 35 35 35 j -i -i3 20 Pressure Drop(PSID) 1.9 4.4 1.9 4.4 ,E8 i ,_1 3 Electrical Data(Amps) 3-rl 29 1 29 115V/60Hz, 1 Phase 3s -1--, Fans(EC Motors) 0.33 0.66 0.66 1.24 Canopy LED Lighting(per row) 0.22 0.33 0.44 0.67 424 Shelf LED Lighting(per row) 0.08 0.10 0.15 0.23 REFRIGERATION--. -A-- PIPING 7 .-ELECTRICAL ACCESS ACCESS J ..._, "..' `.'.:.. ,`RA343'PD,.A✓.1F2SAtaCE �: 3 .1- /'_ fyiiS Off Hotgas Hotgas 1 ;. '2 ~' w Defrost Data Cycle (HFC) TCO2 2s `� X ',5 sup a, 2 , % 3m Defrosts per Day 6 6 6 AREA �z <</,6 1 3.4 45 43 � , ti Failsafe Duration (min)1 29 20 20 -,‘.4; r r, n o _, I9 - Termination Temp (°F) 45 45 45 Drip Time(min) 0 2 2 r r = , Pumpout Time(min) 0 0 10 ...8-1/8.72-11«> STANDARD KICKPLATE LOCATION(PLATINUM 95-3,4 1144-12, H--STANDARD KICK PLATE LOCATION DRAIN CONNECTION--L FRONT OF CASE , (MODERN,CLASSIC) WIT.P-TRAP RIGHT OR LEFT) --OPTIONAL KICK PLATE LOCATION (PLATINUM) Case Length (ft) Refrigeration Data (General) 4' 6' 8' 12' Discharge Air Velocity(fpm) 200-225 200-225 200-225 200-225 Fan Speed (rpm) 2200 2200 2200 2200 Discharge Air Temp (°F) 30 30 30 30 Conventional Thermal Load (Btuh)with one row of canopy LED 6008 9012 12016 18024 Parallel Thermal Load (Btuh)with one row of canopy LED 5536 8305 11073 16609 Additional Btuh per ft LED-Canopy/Shelf& Nose 13/11 13/11 13/11 13/11 HFC Estimated Refri. Charge(Ibs) 1.24 1.85 2.58 3.93 "1 At ASHRAE conditions.For conditions above 75°F,55%RH,increase defrost time by 15 min. Type I refrigerator,intended for use in an area where the environmental conditions are controlled and maintained that conditions do not exceed 75°F and 55%relative humidity.Kysor Warren,whose policy is one of continuous improvement,reserves the right to change at any time specifications,designs,or prices without incurring obligation." AIM CERTIFIED' - . ti t?'° f�d C0USali ` C us LISTED CEPAktMENt OF ENURLY EPH ANSI 1 NSF 7 4 PRELIMINARY I , i` RR A tl 41.2 '' ' 31.2 30.1 -3.0 i~ 0 Case Data Amps 4 FT 6 FT 8 FT 12 FT o i, N Anti-Sweat 1.09 1.33 1.35 2.00 O_U I C ECM Fan/No. 0.20/1 0.40/2 0.40/2 0.60/3 ° I -cS Drain Heater E 0.26 0.26 0.26 0.26 It 14.7 1s.4SV 32.3 Drain Heater HG 0.17 0.39 0.65 1.09 34.0 34.5 0 Electrical Defrost V 4.17 6.52 9.37 14.06 (Electric-208V) MA,,/ �� �_ / 4 A 4 All Electrical Data Based On 115V. f ; ;' v -� 182 Defrost Data 1 1 Defrost Per Day Fail Safe Termination �r- I \ IL 1 Electric 1 60 min 48°F s.o 24.000 -5.7 3.9 \ 41.634 Hot Gas 1 25 min 48°F Add 3"thickness for a pair of ends. 48.25-4'CASE 72.25-8'CASE 1 iiiii ti:.,4,' 96.375-8'CASE ''__ 144.5-12'CASE \i t �\ 8.0 % C 33.0 CI tb 40.0 24.0 17.2 -20.1 3� f.4 / / i i / / / / / „� ! J / 8.0 4.5 ---- ��� i 3:5 Tro.ya-1 � - � 0 a aooa 7.0 1.5 \ \ DRAIN CONNECTION I 7.0 21.8 '---CASE PENETRATION, \--KICKPLATE (WlTRAP RIGHT OR LEFT CASE PENETRATION,) ELECTRICAL LOCATION REFRIGERATION Type I refrigerator,intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55%relative humidity.Kysor//Warren,whose policy is one of continuous improvement,reserves the right to change at any time,specifications,design or prices without incurring obligation.Dual-Jet and Air Defrost are registered trademarks of Kyso r//Warren. CAPACITIES Length(FT) 4 6 8 12 BUTH per FT per Case(ECM Fan) Facing Area(FT2) 11.6 17.3 23.1 34.6 Conventional Parallel Cubic Capacity(FT') 13.2 19.8 26.4 39.6 Medium Temp. 240.3 222.5 REFRIGERATION DATA Low Temp. 334.8 310.0 Application Evap.Temp. Discharge Air Averaged Dis- Temp. charge Air Velocity MOM,,• 0 CD Medium Temp. +24°F +30°F 175 FPM ,° .. Low Temp. -15°F -11°F 175 FPM Kysor//Warren 5201 Transport Blvd 800-866-5596 phone www.kysorwarren.com Issue:9/6/2016 Columbus,GA 3190 706-568-8990 fax Worldwide Refrigeration