Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (2)
CITY OF TIGARD MASTER PERMIT ■ ` COMMUNITY DEVELOPMENT Permit#: MST2023-00598 TIC;A I",II 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 12/06/2023 Parcel: 2S 103AD04300 Jurisdiction: Tigard Site address: 12980 SW 107TH CT Subdivision: PATHFINDER Lot: 33 Project: Newburg Project Description: Rooftop solar PV system 8.000 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $9,013.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Rooftop solar array 8 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: NEWBURG,JOSEPH&LAUREN Required Items and Reports(Conditions) 12980 SW 107TH CT TIGARD,OR 97223 PHONE: PHONE: FAX: Total Fees: $351.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QS9_nn1_nn1n thrnnnh(lAR QF9_M1_nnQn Vnn moo toin o nnnsi f tho n Joe nr rlirort nnoefinne fn(ii inr by rniiinn cnz 919 1QR7 nr 1 Ann 119 9144 Issued By: Permiftee Signature: all 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. Building Permit Application Residential FOR OFFICE USE ONLY City of Tigard i t Reed t�(t l �9 Permit No.. - a 13125 SW Hall Blvd.,Tigard,OR 97223 '� '` Date/By: �� ( g Plan Review II IC' Phone: 503.718.2439 Fax: 503.598.1960 NOVZ Date/By. l( f C3/2� Other Permit: N O Inspection Line: 503.639.4175 Ej Lu ,. Date Ready/By: Juns I El See Page 2 for C,TIAKD Internet Mti:7wwwtigard-or.gov Notified/Method: �, �� iU( Supplemental Information T `PE flF vvQ REQt I b '"1 >Ft ?WEt .INQ ❑New construction ❑Demolition . Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ElAddition/alteration/replacement ❑■ Other:Solar equipment,materials,labor,overhead,and the profit for the -�� workapplication.indicated on this p ication >.. C�.T� QRY 4)F COI�Is'I�tI I . .<. ...-.. Valuation: $9013.00 ❑■ I-and 2-family dwelling ❑Commercial/industrial ❑Accessory building ❑Multi-family Number of bedrooms: ElMaster builder ❑Other: Number of bathrooms: JOB SITE INFORMATION, ND [ 1CATtt) Total number of floors: Job site address:12980 SW 107th Ct New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solarinstall-JNewburg Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-tT:SE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of 20 solar panels in 2 arrays on a roof-mounted 8.000kW PV System Valuation: $ Existing building area: square feet New building area: square feet Q PROPERTY OWNER ❑ TENANT Number of stories: Name:Joseph Newburg Type of construction: Address:12980 SW 107th Ct Occupancy groups: City/State/ZIP:Tigard, OR 97223 Existing: Phone:( )707-999-8238 Fax:( ) New: © APPLICANT N} CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:TML International LLC dba Infinity Solar USA Structural plan review fee(or deposit): Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable): Address:6405 E Mill Plain Blvd Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Phone:( )(360)326-0650 Fax: :( ) Amount received: PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail:permit@infinitysolarusa.com �= Commercial and residential prescriptive installation of CONT ACT I roof-top mounted PhotoVoltaic Solar Panel System. Business name:TML International LLC dba Infinity Solar USA Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )360-326-0650 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:223690 Total fee due upon application: $201.60 Authorized signature: � �,,,// This permit application expires if a permit is not obtained /�Z�GC�24 PG{L4 5'14'L�"5'flt ;z51 within 180 days after it has been accepted as complete. (( *Fee methodology set by Tri-County Building Industry Print name:Mary Dinsmore- Ith Date:11/15/2023 Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application ) �� - ' FOR OFFICE LISE ONLY City of Tigard NO V L tJ 2023 Received Permit#: ''''. DateBy: Eq 7/af Z-'I, 3 I��T ;T�'y'z� . _?, '‘ys' III im 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review _ Phone: 503.718.2439 Fax: 503.598.1960 y�/�p� �y Related Permit#: �" / 1�6P4A DateBy: Inspection Line: 503.639.4175 1 i (4A Ready Date/By: Juris ® See Page 2 for 1.IGAR11 Internet: www.tigard-or.gov BUILDING DIVISIO Notified/Method: Supplemental Information k.""z. . . r: . . ; .'": f t :: Y O!' aTO* ,' e :r+' i i c uzs 4 E ❑New construction ❑■ Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked) ❑Demolition ❑■ Other: Solar ❑Service or feeder 400 amps or more ❑Building over three stories. where the available fault current ❑Marinas and boatyards. ` a ' ...: .... A f 1 Y OF CONSrRUCTIQN "` $ .�s exceeds 10,000 amps at 150 volts or 0 Floating buildings. ■ i-and 2-familydwellingless to ground,or exceeds 14,000 ❑Commercial-use agricultural ❑ 0Commercial/industrial 0Accessory building amps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or .4 00 lox, _, R"°I ON ANI)LO .TION :£ ❑Emerg system. larger separately derived ❑Addition encoyf new motor load of system. Job#: Job site address:12980 SW 107th Ct 100HP or more. ❑"A","E","1-2","1-3", City/State/ZIP:1 Tigard, OR 97223 ❑Six or more residential units. occupancy. ❑Health-care facilities. ❑Recreational vehicle parks. ❑Hazardous locations. 0 Supply voltage for more than Suite/bldg./apt.#: Project name:Solarinstall-JNwwburg600 volts nominal. ❑Service or feeder 600 amps or more Cross street/directions to job site: , E>SCHEDULE D v escription I Qty. I Each I Total I New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1 "' "'' 3ESCRiPTION OF WORK Limited energy,residential (with aboq.ft.) 75.00 2 Installation of 20 panels in 2 arrays on a roof-mounted 8.000kW PV system Limited energyves,multi-family residential(with above sq.ft.) 75.00 2 Renewable Energy III See Page 2 ® PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name:Joseph Newburg 200 amps or less 100.70 2 Address:12980 SW 107th Ct 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, OR 97223 601 amps to 1,000 amps 301.04 2 Phone:( )707-999-8238 Fax: ( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:bobobaju@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 t intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ® APPLICANT ©'CONTACT PERSON ABraec fho crbaunictsh—ci rnceuwts awlittehatin,o extenion, ter panel Business name:TML International LLC dba Infinity Solar USA above service or feeder fee, 7 42 2 each branch circuit Contact name:Mary Dinsmore-Smith B.Fee for branch circuits without service or feeder fee,first Address:6405 E Mill Plain Blvd branch circuit 56.18 2 City/State/ZIP:Vancouver WA 98661 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( )360-326-0650 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:permit@infinitysolarusa.com Reconnect only 67.84 2 C©NTRA CTOR Pump or irrigation circle 67.84 2 Business name:TML International LLC dba Infinity Solar USA Signor outline lighting 67.84 2 Signal circuits)or limited-energy Address:6405 E Mill Plain Blvd panel,alteration,or extension. ❑ See Page 2 2 City/state/zIP:Vancouver WA 98661 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( )360-326-0650 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr min) 78.18/hr Email:permit@infinitysolarusa.com Inspections for which no fee is CCB Lie.:223690 Electrical Lie.:C1556 Suprv.Lie.:4434S specifically listed(/2 hr min) 90.00/hr / n .,, .' LECI'RI AL PERMIT FEES : - Suprv.Electrician signature,required: -eicZ /et,. Subtotal: Print name:Todd Rouse Date:11/15/2023 0 Plan Review Required(25%of permit fee): 7� State surcharge(12%of permit fee): Authorized signature: GiZ4412.62.42",5)frt TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Date:11/15/2023 Print name:Mary Dinsmore-S Ith days after it has been accepted as complete. * Number of inspections allowed per permit. t.\Building\Permits\ELC_PermitApp_ELR_ERE_doc Rev 06/17/2015 440-46151'(t 1/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: R SIDuNTiAL WOR Ol LY. y: r E: ,Descr I * Fee for all residential systems combined: $75.00 n Qty. Each Total Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 • Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(Yz hr min) COMMERCIAL WORK ONLY:' ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): y * Number of inspections allowed per permit (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermitApp_ELRERE.doc Rev 06/17/2015 City of Tigard � S�� • '' Building Division ' �' 13125 SW Hall Blvd,Tigard, OR 97223 RECEIVED Phone: 503.718.2439 Fax: 503.598.1960 NOV2 0 2023 T I GARD Inspection Line: 503.639.4175 www.tigard-or.gov cmi OF 3 a A D BUILDING DIVISION! 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12980 SW 107th Ct City: Tigard Zip: 97223 Owner's Name:Joseph Newburg Date: 11/15/2023 Contractor's Name:TML International LLC dba Infinity Solar USA CCB #: 223690 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ❑■ No OSSC or ORSC for design requirements. Wind Ex osure Is the wind exposure ❑� Yes If"Yes", qualifies for p "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑■ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ❑ Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction material wood and does ❑� Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light ❑ No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. n Yes If"Yes", qualifies for the prescriptive path. n No Roof framing members Is the spacing 24 inches or less? Nominal lumber. El Yes "Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight n Yes of the PV modules and If"Yes", qualifies for racking less than or n No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑■ Yes with Section 305.4(3) of If"Yes", qualifies for Elthe 2010 Oregon Solar No the prescriptive path. Code? n Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑■ of composition shingle. Is the roof mounted n Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No framingblockingthe prescriptive path. to the roof or directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ❑� Yes the prescriptive path. surface. ❑ No 3 I:/Building/Forms/PhotoVoltaic-Checklist02-O 1-11.docx 4 Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:S I L FAB Model Number:SIL-400 HC+ Listing Agency: UL 61730 4 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx