Loading...
Permit (12) CITY OF TIGARD MASTER PERMIT `N a . , COMMUNITY DEVELOPMENT Permit#: MST2023-00586 T I G A Ix D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 12/05/2023 Parcel: 2S106DD06500 Jurisdiction: Tigard Site address: 13614 SW 165TH AVE Subdivision: RIVER TERRACE TOWN CENTER Lot: 66 Project: River Terrace Town Center, Lot 66 Project Description: New detached dwelling. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 3 First: 1880 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 19 Bathrooms: 3 Second: 0 sf Garage: 468 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 1880 sf Value: $347,629.68 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add"500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 1880 Owner: Contractor: TNHC OREGON LLC TNHC OREGON LLC Required Items and Reports(Conditions) BY THE NEW HOME COMPANY INC 15231 LAGUNA CANYON ROAD 1 Ersn Cntrl 503-639-4175 BY KAWANAMI,MARK SUITE 250 15231 LAGUNA CANYON RD STE IRVINE,CA 92618 250 PHONE: PHONE: 503-312-6213 FAX: Total Fees: $22,766.36 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENT• : Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc7_nn1-nnln thr,, - QS)-nnl-nnQn Vn ,nhtain a rnm,of tha nilnc nr rlircrt ni lactinnc to(ll IN(:by Tallinn ri(V 919 1Q317 nr 1 Rnn 147 71.1 AO. . Issued By: Permittee Signature: u r0.c* tL_OLf Call 503.639.4175 by 7:00 a.m.for the next available inspection date. is permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applicatio .-... Residential FOR OFFICE FSI?ONLY City of Tigard NOV 9 2023 Received / ^ Date/B : ( • 1'F Permit No.: i i '1 • r ' 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review i VVV Phone: 503.718.2439 Fax: 503.598.196 Other Permit: �� r CITY OF TIGARD Date/B : ;�_ Ilk i M � T I G A R D Inspection Line: 503.639.4175 Date Ready/By: r la See Page 4 fo BUILDING DIVISION > Internet: www.tigard-orgov b IS Notified/Method: I I -1 2 Supplemental Information El New construction El Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement ❑Other + E " . ... equipment,materials,labor,overhead,and the profit for theito m ` � � ' � � � � ` workindicated on this application. . : : „ . .. # � � � y � � * 31 �,(off 1-and dwelling Valuation: $1 , ❑ g El ElAccessory building ID Multi-familyNumber of bedrooms: 3 ❑Master builder El Other: Number of bathrooms: �!r Total number of floors: 2' Job site address:13614 SW 165th Avenue New dwelling area: 1880 square feet 1 905 0 City/State/ZIP:Sherwood, OR 97140 Garage/carport area: 468 square feet Suite/bldg./apt.no.: Project name:River Terrace Town Center Covered porch area: 56 square feet Cross street/directions to job site: Deck area: square feet -SW Jean Louise Road Other structure area: square feet Subdivision:River Terrace Lot no.:66 Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no parcel no: 2S 1060003300 equipment,materials,labor,overhead,and the profit for the VINa `:DESCRI 'ION `W ( '�_,, ` , y work indicated on this application. Valuation: $ Requesting Deferred SDC fees Existing building area: square feet New building area: square feet v 1 `T' ER `ANT NN Number of stories: Name:TNHC OREGON LLC Type of construction: Address:15231 Laguna Canyon RD STE 250 Occupancy groups: City/State/ZIP:Irvine/CA/92618 Existing: Phone:(503)310-7571 Fax:( ) y Business name.TNHC OREGON LLC o g"'' i a ``�.„:BMI . IVIIfif. Structural plan review fee(or deposit): Contact name:Frank Sandoval FLS plan review fee(if applicable): Address:15455 NW Greenbrier Parkway Suite 240 Total fees due upon application: City/State/ZIP:Beaverton/OR/97006 Amount received: Phone:(503) 310-7571 Fax: :( ) E-mail: fsandoval@nwhm.com/oregonpermits@newhomeco.com rOvOLT 1�1aI ,A. ;fFE Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:TNHC OREGON LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:15231 Laguna Canyon RD STE 250 Solar Installation Specialty Code checklist. City/State/ZIP:Irvine/CA/92618 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503 )310-7571 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:241108 Total fee due upon application: $201.60 Authorized signatur . 1 L.//' .Y.J-E lr1411.,04 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Jennifer Mc rmott Date:11/9/2023 *Fee methodology set by Tri-County Building Industry Service Board. I:ABuilding\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Y . Mechanical Permit ApplicattECEIVF1) FOR oFrlc l: USE ONLYCl of Tig6ard Received b Date/By: Permit No.: 13125 SW Hall Blvd.,Tigard,OR 97223 MST2o23—OD5�6 _ j Phone: 503.718.2439 Fax: 503.598.196Al O N 9 2023 t Plan Review Other Permit: TIGARD Inspection Line: 503.639.4175 DateReady/By: Juris 0 See Page 2 for Internet. www.tigard-or.gov CITY OF TIG A RD Notified/Method: Supplemental Information BUILDING DIVISION TYPE OF WORK . CON.I)41EItC ;IfiEE* SCR)l V,E.alfCK;•ice' Mechanical permit fees*are based on the value of the work ®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CAt SCARY C)lf AIYS"if€1IC"1"It IY I[!E [11:e L EQ11P NT t$YS"E S flE ' ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION A :I< CA1(`IOI Heating/cooling: Air conditioning 1 46.75 Job site address:13614 SW 165th ave Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Sherwood OR 97140 Furnace 100,000+BTU(ducts/vents) 1 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:River Terrace Town Center Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or SW Jean Louise rd hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:River Terrace Town Center Lot no.:66 Other fuel appliances: Tax map/parcel no.:2s1060003300 Water heater 23.32 RESCRI `IOAI OF WIRIK.:. Gasfireplace/insert 1 33.39 Flue vent for water heater or gas NEW HOME CONSTRUCTION fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ga PROPER?Y OVER ' NAN11 Other: 23.32 Environmental exhaust and ventilation: Name:TNHC OREGON LLC Range hood/other kitchen equipment 33.39 Address:15231 Laguna Canyon Rd STE 250 Clothes dryer exhaust 33.39 City/State/ZIP:Irvine CA 92618 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)10-7571 Fax:( ) Attic/crawlspace fans 23.32 tA AP tt*If 0 t:ii tfA o fimet4 Other: 23.32 Business name: TNHC OREGON LLC Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Frank Sandoval Furnace,etc. Address:15455 NW Greenbrier Parkway#240 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Beaverton OR 97006 Water heater Phone:(503)310-7571 Fax: :( ) Fireplace Range E-mail:fandoval@nwhm.com Barbecue .. : �::' ON' A 'O . '' ". ..! Clothes dryer(gas) Business name:Pro Heating and Cooling, INC Other Address:4200 NW Leisy rd Subtotal City/State/ZIP:Hillsboro, OR 97124 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(971)205 4989 Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: Z711-4- 41" * Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date:3/17/2023 1:\Building\Permits\MEC_PermitApp_040113.doc 440-4617r(11/02/COM/WEB) Electrical Permit Applicatio E I V Erb FOR OFFICE USE ONLY City of Tigard Received 11 a 13125 SW Hall Blvd.,Tigard,OR 97223 N U V 9 2023 Date/By: Permit#:m ST 2Q�3—p05g6 PlaS Phone. 503.718.2439 Fax: 503.598.1960 Dal Review ateBy: Related Permit#: T t C A R D. Inspection Line: 503 639.41 75 ��-f t� l� Ready Uate/By: Sans: El See Page 2 for Internet: www.tl ard-or. ovY TIGARD b' g NotfiedMethod: Supplemental Information .DING DIVISION IO TYPE,OF PLAN REVIEW ®New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans whtems checked): El Demolition �Yher: 0 Service or feeder 400 amps or more 0 Building over three stories. where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. 1:/ 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑Multi-family amps for all other installations. buildings. ❑Master builder ❑Other: 0 Fire pump 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived Job#: Job site address: 13614 SW 165th Ave 0 Ad 100 HP HP o or of moew motor load of system. more. ❑"A","E","!-2","I-3", City/State/ZIP: Sherwood/ OR/97140 0 Six or more residential units, occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: RTTC ❑Hazardous locations. ❑Supply voltage for more than ❑Service or feeder 600 amps or more 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE SW Jean Louise Rd. Description I Qty. I Each l Total f New residential single-or multi-family dwelling unit. Subdivision: River Terrace Town Center Lot#:66 Includes attached garage. Tax map/parcel#: 2s1060003300 1,000 sq.ft.or less 168s4 4 Ea.add'l 500 sq.ft or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential NEW HOME CONSTRUCTION (with above sq.ft.) 75.00 2 Limited energy,multi-family residential(with above sq.ft.) 75.00 2 PROPERTY OWNER TENANT Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation Name: THNC OREGON LLC 200 amps or less 100.70 2 • Address: 15231 Laguna Canyon Rd STE 250 201 amps to 400 amps 133.56 2 City/State/ZIP: Irvine CA 92618 401 amps to6oaamps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:(503)310-7571 Fax:( ) Over 1.000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: Fsandoval@newhomeco.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 5936 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 14 APPLICANT 13 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel THNC OREGON LLC A.above ericeor eederfee, Business name: above service or feeder fee, each branch circuit 7.42 2 Contact name: Frank Sandoval B.Fee for branch circuits without service or feeder fee,first Address: 15455 NW Greenbrier Parkway#240 branch circuit 56.18 2 City/State/ZIP: Beaverton OR 97006 Each add'I branch circuit 7.42 2 Phone:(503)310 7571 Fax::( ) Miscellaneous(service or feeder not included) Each manufactured or modular 67.84 2 dwelling,serviceandJorfeeder Email: Fsandoval@newhomeco.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Development Northwest Inc., DBA Wolcott Electrical Sign or outline lighting 67.84 2 Address:1075 W Historic Columbia River Hw Signalcircuit(s)orlimited-energy y panel,alteration,or extension. ❑ See Page 2 2 City/State/ZIP:Troutdale, OR, 97060 Each additional inspection over allowable in any of the above Additional inspection(7 hr min) 66.25/hr Phone:(503)853-9420 Fax:( ) Investigation(1 hrmin) 90.00/hr Email:MWOLCOTT@WOLCOTT.PRO Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lie.:112220 Electrical Lic.:C 1272 Suprv.Lie.:5782S specifically listed(i4 hr min) 90.00/hr Suprv.Electrician signature,required E CTRICAL'PERMIT FEES K,nna�, 7 . ,. Subtotal: Print name:David Campbell Date:10/12/2023 ❑Plan Review Required(25%of permit fee): /n State surcharge(12°/0 of permit fee): Authorized signature: 4 TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Malachi J. Wolcott Date:10/12/2023 days after it has been accepted as complete. . Number of inspections allowed per permit. L\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COMIWEB , Plumbing Permit APPlic ' r Building Fixtures tk. 101 OFFI('E 1st: oNl,l City of Tigard Received g Date/By: Permit No.:m ST 202 3_005�6 v 13125 SW Hall Blvd.,Tigard,OR 9'7 23 p tS Plan Review Phone: 503.718.2439 Fak: 503 6 Other Penmil No.: p L'I I urr (ILkl'ataD DateRe Inspection Line: 503.639.4175 r a i , 7 I GA ILIA BUILDING &tt r b„ ter„j NDote Ready/By. Jura S See Page2 fnr Internet. www.tigard-or.gov@ It ''".Iw-L 1 oufied/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction ❑Demolition For special infornrntion use checklist. Description I Qty. 1 Ea. I "total ❑Addition/alteration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® I-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 1 43778 ❑Accessory building ❑Multi-family SFR(3)bath 500.32 Each additional bath/kitchen 25.02 ❑Master builder ❑Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 13614 SW 1 65th Ave Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18.76 City/State/ZIP: Sherwood/OR/97140 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: I Project name: RTTC Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 SW Jean Louise Rd. Rain drain connector 18.76 Sanitary sewer(no linear ft.._) Page 2 Storm sewer(no linear ft.: ) Page 2 Water service(no linear ft:_) Page 2 Subdivision: River Terrace Town Center I Lot no.: 66 Fixture or item: 'Fax map/parcel no.: 2s 1060003300 Backflow preventer 31.27 DEsetttrTION OF WORK; Backwater valve 12.51 New Home Construction Clothes washer 25.02 Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 21 PROPERTY OWNER 1 0 TENANT Expansion tank 12.51 Name: TNHC OREGON LLC Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address: 15231 Laguna Canyon Rd STE 250 Garbage disposal 25.02 City/State/ZIP: Irvine CA 92618 Hose bib 25.02 Phone:(503)310-7571 Fax:( ) Ice maker 12.51 0-4 'APPLicANT CONTACT.PERSON Interceptor/grease trap 25.02 Business name: THNC OREGON LLC Medical gas(value:$ ) Page 2 Primer 12.51 Contact name: Frank Sandoval Roof drain(commercial) 12.51 Address: 15455 NW Greenbrier Parkway#240 Sink/basin/lavatory 25.02 City/State/ZIP: Beaverton OR 97006 Solar units(potable water) 62.54 Phone:(503)3 1 0-7571 Fax::( ) Tub/shower/shower pan 12.51 E-mail: Urinal 25.02 C©NTRACTO Water closet 25.02 Water heater 37.52 Business name:VVolcott Plumbing Water piping/DWV 56.29 Address:1075 West Historic Columbia River Hwy Other: 25.02 City/State/ZIP:Troutdale OR. 97060 Subtotal Phone:( 503_667-1781 Fax:( ) Minimum permit fee: $72.50 Pltunbin Lie.no.: g 26824 PB Plan review (25%of permit fee) CCB Lia:112220 State surcharge of permit fee) Authorized signature: ��`k1v K_________ TOTALTAL PERMIT FEE Print name:Mark Baleme Date:10/12/2023 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. °Fee methodology set by Id-County Building Industry Service Board. IanuitdingtPermits\PLMU•PermitApp_doc 10/01/09 440-4616T(l0/02/COM/WEB) 111 Building Division One & Two-Family Dwelling TIGARD Fees Checklist PERMIT INFORMATION: Application Date - FEE VERSION `�l2 Permit #: iy\e T2,02,3 �y [4(p Plan #: 5L 5) 6 Floors: I Valuation: 3l -7 ce$ Covered Porch: 5-� Basement �� , Bedrooms: 3 Deck: 1"Floor 1 Si3-bo WC (toilets) Deck Cover: 2"d Floor Lavatories LI Patio Cover 3rd Floor _ Tub/shower 2 Accessory Struct. ---_ R-3 Total ^ deo Laundry Tray — Water Heater i / Gas / F.lec� Garage Li (PS Exhaust Vents S Gas Flue Vents Total for Elec. 7/ L( Backflow Prey. eat Pump CAC --) # for Electrical 3 BBQ Gas Fireplace y-A---s #Fuel Lines 3 FEES: Description: Fee rie : Fee Entered: DC Prov Revw: Planning Info Proc/Arch: Lg $2.00 (over 11x17) I cl Info Proc/Arch: Sm $.50 (up to 11x17) y ( Metro CET: Residential Use School CET: District:l I - Tigard CET: Admin 1 .' Tigard CET: ODHCS 1/ - Tigard CET: AH ✓^ Electrical Permit: Permit Fee: L ^ Limited Energy: 12% State Surcharge ✓— Mech. Permit: Permit Fee: 12% State Surcharge Plumbing Permit: Permit Fee: 12% State Surcharge �---- Erosion Control: w/Permit - Ping 1:\Building\Forms\ResPlanCheckFees_Dec2022_AA.doc 12/21/22 Page I City of Tigard B ill COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Review - Residential TIGARD ;; r Building Permit #: N154'L()�, GGS�S Site Address: 13614 SW 165th Avenue Verified in Ac cela ccela Project Name: River Terrace Town Center Lot/Unit #: 66 Proposal: New Single Detached Zone: RES-C Housing Type: 0 SFR('Single Detached 0 Duplex 0 Triplex 0 ADU) 0 Rowhouse ❑Cottage Cluster El CYU ❑Quad ❑Other Required Site Plan Elements: V 3 copies of site plan on max 11x17" PI Drawn to standard scale ❑ Retained li ees, di iE, lii is/ bee III utcLlion 0 North arrow V Street and site trees shown / labeled 0 Site address, project name, lot # El—Table-calculating tree canopy at maturity V Street names (N/A for SFR) vApplicant name and phone # plicable) 'Lot and setback dimensions t +sien clearance trial:14e ❑ Existing structures &squab fuotaye 'Utility locations &easements 'Footprint of new structure and FFE 0 Property corner elevations 0 Sidewalk/driveway dimensioned 9.1"40*-(-->1,000 sf disturbance) l 'Lot area and lot coverage percentage V Erosion control Required Elevation Plan Elements: (For SFR: calcs needed only on street-facing) Summary table with calculations for: 'Drawn to standard scale vi Total façade area V Building height dimensioned V Total window and door area vi Façade dimensioned V Windows and doors dimensioned 0 Garage doors dimensioned Requir an Elements: (Not required for SFR ❑ Summary table that includes ❑ Each story dimensioned otal floor area O Each story floor area calculated ❑ Floor ar Planning Review The following standards have been met: 8'porch 15'budding 20, Setbacks V Front:12'building Rear: 10'patio Side: 3 Min/Max Street Side: 7' / Garage: Height V Max. Height: 35' Proposed Height: 18' 7 1/4" 'Yes ❑ N/A Landscape O Yes It N/A Screening (Quad only) V Yes ❑ N/A % Window Coverage \9'f• VYes ❑ N/A Garage (SFR Only) Parking (Other Res) vYes ❑ N/A Entrance (SFR, Rowhouse, Quad only) ❑ Yes N/A Other building design standards (Rowhouse only) O Yes N/A Accessory Structure Standards ❑ Yes No Qualifying pre-existing unit exempt from standards (Cottage unit only) Additional standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads: ❑ Yes N/A Unit Count: ❑ Yes N/A Lot Width and Size O Yes N/A Pathway Additional standards for Courtyard Units and Cottage Clusters only: ❑ Yes N/A Unit Area: O Yes N/A Floor Area (per story) ❑ Yes N/A Courtyard O Yes N/A Fence ❑ Yes ❑ No 'N/A Clean Water Services - Service Provider Letter (lot platted prior to 9/10/1995) ❑ Yes ❑ No ON/A Public Facilities Improvement (PFI) Permit: Required: Yes ❑ No Applied For: V Yes ❑ No, stop intake Vf Sensitive Lands: ❑ Yes tif No 'Main Land Use Case #s: PDR2021-00004 ❑ Conditions met 'Applicant notified of Ian u pi te: Submit and pay for all applicable dev permits by 1/31/2025.Final occ by 1/31/2027 Approved By Planning: ll,.�---- Date: 11/1/2023 Notes Revision 1: ❑ A roved ❑ Not Approved Date: Revision 2: ❑ A proved ❑ Not Approved Date: Building Permit Submittal Original Submittal Date: i 1 Site Plans #: Building Plans #: Building Permit #: 1/Building pergiit # entered on page 1 Workflow Routing: IF/Planning 6d'Engineering IS4ermit Coordinator i&4/Building Workflow Sign-off: 'Sign-off for Planning (include notes from planning review) Route Documents: Engineering: (1) copy of permit application, (1) site plan, (1) building plan ant original plan review routing form. 'Building: original permit application, site plans, building plans, engineer and beam calculations and trust details, if applicable, etc. Permit Technician: '\ .-i V a4�' U LAt‘,(A� Date: i\\GI1,ati3 Notes: Engineering Review ❑ PFI Permit: dirSlope at building pad: .�� 0/0 N/A ('Conditions met prior to issuance of permit nd'Easements (encroachments) per engineering conditions of approval and plat "Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes 111No Assess Water Quantity Fee in-lieu: ❑ Yes Ed4lo LIDA Facility on lot: ❑ Yes Who Add Fee: 0 Yes ❑ No Final Plat Recorded ❑ NOT Approved: Date: Notes: Approved By Engineering: Date: /V-5/2 Revision 1: ❑ Approve Not Approved Date: Revision 2: ❑ Approved ❑ Not Approved Date: Permit Coordinator Review //Conditions met prior to permit issuance ❑ Approved, NOT Released: Date notified applicant: ❑ ENG Revisions Required: Date notified applicant: s c SDC Exemption: ❑ Applied for ❑ Received,, hoes not apply 421 SDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes 0 N/A Tigard Trans SDC: Yes 0 N/A Deferred Parks SDC: Yes ❑ N/A Deferred LIDA ❑ Yes —N/A � to Issue/Approved by Permit Coordinator: � } �Date: ( ✓ 1 `- " 3 /‹..OK Revision 1: ❑ Approved ❑ Not Approved Date: Revision 2: 0 Approved ❑ Not Approved _ Date: