Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (7)
lie ii CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2023-00575 Date Issued: 11/14/2023 T tGAR.D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S112CB18500 Jurisdiction: Tigard Site address: 15120 SW 81ST AVE Subdivision: CORBIN ESTATES Lot: 2 Project: Yuzon Project Description: Rooftop solar PV system. 13.12 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $23,540.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Rooftop solar array 13.12 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: YUZON,DENNIS ALFONSO NATIONAL SOLAR INC Required Items and Reports(Conditions) YUZON,PAULA BALLARD 2709 NW CROSSING DRIVE 15120 SW 81ST AVE BEND,OR 97703 TIGARD,OR 97224 PHONE: PHONE: 253-359-1444 FAX: Total Fees: $347.16 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QF9-nnl-nMn thrni inh(lAR OF9-nnl/-nnon vni i ma„nhfain i of tha ri dac nr rllrart ni ioctinnc to flu IM(:by Tallinn Fn'2 919 1QR7 nr'I RM 139 94dG liffee....zZpli; Issued By: ,4-rL - 7 Permittee Signature: f -f'' 03.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE USE ONLY City of Tigard RECEIVE ' eceived �k Date/By: ,`l`Y 1^01/S• lap u cosi 5 IN 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review f Permit No.: �s J • Phone: 503.718.2439 Fax: 503.598.1960 OCT T 1 'l 2023 y: ', , 7.a3 / Other Permit: U l� Date/BY: / / T 1 G:1 R t) Inspection Line: 503.639.4175 Date Ready/By: J is: H See Page 4 for Internet: www.tigard-or.gov Notified/Method: Y/73 / 7'7 Supplemental Information CITY OF TIOARD , a; ��l �y ❑New construction ❑Demolition Permit fes e *are based on the value of the work me perford. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement [Other: SOLAR equipment,materials,labor,overhead,and the profit for the""Iii jilt " i , R t,' work indicated on this application. , 23,540 [�1-and 2-family dwelling ❑Commercial/industrial Valuation: $ Accesso buildin Number of bedrooms: ❑ ry g ❑Multi-family III Master builder ID Other: Number of bathrooms: w / ,, ' :: i da i o i a ��%.5 `%; ?° Total number of floors: Job site address: 15120 SW 81st Ave. New dwelling area: square feet City/State/ZIP: Tigard, OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: I Project name: Solar for Yuzon Covered porch area: square feet Cross street/directions to job site: Deck area: square feet NE of SW Hall Blvd. and SW Ashford St. Other structure area: square feet Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. R2195627 Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no equipment,materials,labor,overhead,and the profit for the : ° �i J 4 i �i€T work indicated on this application. mod,,,,,,, :%, ,_ ,�,,,,,,, -,,'„ --' /' , .o. V", ..�.. PP Installing 13.12kW solar pv system on roof of home. Valuation: $ 32 REC 410AA Pure modules and 16 Chilicon CP720 Existing building area: square feet microinverters. New building area: square feet i * ® 04 /' Er Number of stories: Name: Dennis Yuzon Type of construction: Address: 15120 SW 81 St Ave. Occupancy groups: City/State/ZIP: Tigard, OR 97224 Existing: Phone:(503539-4521 Fax:( ) New: Business name: National Solar E Structural plan review fee(or deposit): Contact name: Lynnette Harley FLS plan review fee(if applicable): Address: 2709 NW Crossing Dr. ty Bend, OR 97703 Total fees due upon application: City/State/ZIP: 877}785-2582 Amount received: 2534359-1444 Fax::( Phone:( E-mail: L nnette nationalsolarusa corn : - .. % ., \`... " , / � Commercial and residential prescriptive installation of °rail ig , E,,,,,-' °r- Orr $444 a ,,, ir, �z ,,, • roof-top mounted PhotoVoltaic Solar Panel System. Business name: National Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 2709 NW Crossing Dr. Solar Installation Specialty Code checklist. City/State/ZIP: Bend, OR 97703 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(800)-808-1955 Fax:(877-785-2582 State surcharge(12%of permit fee): $21.60 CCB lie.: 186224 '/ Total fee due upon application: $201.60 Authorized signature: 7/7a h This permit application expires if a permit is not obtained 777r' within 180 days after it has been accepted as complete. Print name: Lyn nette H ley Date: 10/26/2023 "Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY City of Tigard Received Permit No.: _IN a 13125 SW Hall Blvd.,Tigard,OR 97223 Y g Associated permits: Phone: 503.718.2439 Fax: 503.598.1960 24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical I I UA RI) Internet: www.tigard-or.gov 0 Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. n Z/ 3 Verification of approved plat/lot. n IZI 4 Fire district approval required. Name of district: n n 5 Septic system permit or authorization for remodel. Existing system capacity . n n 71 6 Sewer permit. n n 7 Water district approval. n n 8 Soils report. Must carry original applicable stamp and signature on file or with application. n n 71 9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ n basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ® 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if U U there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ 0 21 and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ 13 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ El floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 0 El Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ 0 lI prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ 0 12 locations. Show attic ventilation. - 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 ❑ systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ 0 Ei over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. Cg 0 ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ® ❑ 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ 0 CM architect licensed in Ore!on and shall be shown to be a.i licable to the .ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ► • 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ® ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ® n n 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. n n 0 27 "Drawn to scale"indicates standard architect or engineer scale. 11 El28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard lil Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ [2 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 21 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9,1995. I:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY City of Tigard Received Permit#: MS1/li,A Q. /j51111 5 1 Pl 13125 SW Hall Blvd.,Tigard,OR 97223 Date/By:an ew Revi vv b J rn 2 Phone: 503.718.2439 Fax: 503.598.1960 ff Date/By: Related Permit#: Inspection Line: 503.639.4175 t , Ready Date/By: Iris: I ® See Page 2 for T I E;A C:I1 Internet: www.tigazd-or.gov Notified/Method: Supplemental Information ❑New construction 12 Addition/alterationllacet}1`enf - Please check all that apply(submit a sets of plans w/items checked): ❑Demolition lif Other: SOLAR ❑Service or feeder 400 amps or more ❑Building over three stories. � where the available fault current Marinas and boatyards. .. /i..i E. , "! ,,,,40 , ,✓„ " "",,,^ r exceeds 10,000 amps at 150 volts or 0 Floating buildings. IA 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi family 0 Master builder Other:❑ ti; Fire pump. 0 Installation of 150 KVA or z € "�`c '7 40i a: .,, ❑Emergency system. larger separately derived 15120 SW 81 st Ave. ❑Addition of new motor load of system Job#: Job site address: 100HP or more. ❑"A","E","1-2","1-3", City/State/ZIP: Tigard, OR 97224 ❑Six or more residential units. occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: Solar for Yuzon ❑Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more 600 volts nominal. Cross street/directions to job site: r "l NE of SW Hall Blvd. and SW Ashford St. Description Qty. 1 Each 1 Total 1 New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: R2195627 1,000 sq.ft.or less 168.54 4 E,, Ea.add'l500 sq.ft.or portion 33.92 1 J W:., .�,R SOX'„ "" Y „, ntr,H. -2`r...,,;„ Limited energy,residential (with 75.00 2 (with above sq.ft.) Installing 13.12kW solar pv system on roof of home. Limited above energy, multi-family 75.00 2 residential(with above sq.ft.) R E (2( 2 �` NC ' `" iii " i U Services or feedersnergy installation,alteration,SeePage and/or relocation Name: Dennis Yuzon 200 amps or less 100.70 2 Address: 15120 SW 81 St Ave. 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard, OR 97224 601 amps to 1,000 amps 301.04 2 Phone:(503-539-4521 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: dennisyuzon99@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 l"i v� t, yii ' $ t : — ti , rextensi perpanel Branch circmts new,alters'ono 'on, a ...." �t<<, € .:, A.Fee for branch circuits with Business name: National Solar above service or feeder fee, 7.42 2 each branch circuit Contact name: Lyn nette Harley B.Fee for branch circuits without Address: 2709 NW Crossing b D r. branch circuit 56.18 2 City/State/ZIP: Bend, OR 97703 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(2531359-1444 Fax::(877485-2582 Each manufactured or modular Email dwelling,service and/or feeder 6 2 7.84 Lynnette@Dationalsolarusa.com a( nationalsolarusa com Reconnect onl 67.84 2 r �,,,, i.. i !�.., ,,.. .. fi: l! v a ,,,,, Pump or irrigation circle 67.84 2 Business name: National Solar Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 2709 NW CrossingDr. 0 See Paget 2 panel,alteration,or extension. City/State/ZIP: Bend, OR 97703 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(2534359-1444 Fax:(877)785-2582 Investigation(1 hr min) 90.00/hr Email: Lynnette@nationalsolarusa.com Industrial plant(lhrmin) 78.18/hr Inspections for which no fee is CCB Lic.: 186224 Electrical Lic.: C 1512 Suprv.Lic.: 6051 S s ecificallY listed %hr 90 00/hr Suprv.Electrician signature,required: l ()tam.,'YL .: i (/�7 el Subtotal: Print name: Cody Oram Date: 10/26/2023 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): çAuthorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: er,it 7/ Date: 10/26/2023 days afrer it hen been accepted as complete. • Number of inspections allowed per permit. I:\Building\Permits\ELC App_ELR_ERE.doc Rev 06/17/ 5 440.4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: ;." • Fee for all residential systems combined: $75.00 Description fie., : Each Total Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections fi h for which no mfrene)is fig't 90.00/hr sted '14 hr Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): * (SEE OAR 918-309-0000) Number of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:1Building\Permits\ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015 %S1'w1,3 ()0S1S City of Tigard 1111 Building Division RECEIVED 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960OCT 3 1 207 3 T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov ITY OF I BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 15120 SW 81st Ave City: Tigard Zip: 97224 Owner's Name: Dennis Yu7on Date: 10/26/23 Contractor's Name: National Solar CCB #: 186224 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? El No OSSC or ORSC for design requirements. Is the wind exposure E Yes If"Yes" qualifies for Wind Exposure ,"C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes E Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for above Yes the prescriptive path. ❑ No 1 I:Building/Forms/Photovoltaic-Checklist02-01-1 t.docx Is the construction Type of material wood and does Yes « the construction qualify ht If Yes ,qualifies for Construction ❑ No the prescriptive path. as"conventional lig frame"construction? Is the spacing 24 inches or less? If"Yes",qualifies for Pre-engineered trusses. Yes the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. � Yes If"Yes",qualifies for the prescriptive path. ❑ No Is the combined weight © Yes of the PV modules and If"Yes",qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance v Yes If"Yes",qualifies for with Section 305.4(3)of No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked,qualifies for Max.two layers the prescriptive path. O of composition shingle. Is the roof mounted El Yes Connections of solar assembly If"Yes",qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 inches inches ,qualifies for the directly to Maximum 60 inches standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes",qualifies for fastener? ❑ the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, ❑ Yes decking connected to If"Yes",qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof © Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/Photovoltaic-Checklist02-01-1 1.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines,and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Model Number: REC410AA Listing Agency: UL 4 I:Buiiding/Forms/PhotoVoltaic-Checklist02-01-11.docx