Permit (3) IN CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2023-00566 T I G A IZ I_) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 11/13/2023 Parcel: 2S109BA08400 Jurisdiction: Tigard Site address: 13612 SW LEAH TER Subdivision: DAFFODIL HILL Lot: 10 Project: Blechman Project Description: Rooftop solar system 12.3 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 5 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Total: 0 sf Value: $15,500.00 Rear: 5 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Rooftop solar array 12.30 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: BLECHMAN,NICHOLAS K SUNPATH SERVICES LLC Required Items and Reports(Conditions) 13612 SW LEAH TER PO BOX 751 PORTLAND,OR 97224 CANBY,OR 97013 PHONE: PHONE: 503-313-7253 FAX: Total Fees: $351.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance 'h approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTE N: egon law require ou to follow the rules adopted by the Oregon Utility Notification Center. se rules are set forth in OAR oc9_nn1_nnin thr inh c9_nn1_nnon ni i tain n rnnv of tha ndcc nr direr}nnoctinnc to(II INC!h.,Tallinn Q 719 1QR7 nr nn 19 91dd Issued By: �t'°G Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application EC Residential EIVED FOR OFFICE USE ONLY ' CI of Tigard OCT 3 , 2023 Receive � � � ] �-- g Permit�, ' 3 U / 1111 13125 SW Hall Blvd.,Tigard,OR 97223 DateB `i,.� �r- ���+�G ■ Plan Review Phone: 503.718.2439 Fax: 503.598. Date/By: II •• rj' a '3 I Other Permit: Inspection Line: 503.639.4175 OF TIGARD y y: �� ! ® See Page 4 for T'I l 1 K f) Dale Read B �J Internet: www.tigard-or.gov BUILDING DIVISION ,Notified/method: 1 l\ Supplemental Information SiNS 1' . . Y,, m + +" ..P 't Fie^r , w�2it, "S w,--1 R,5 s*g a :g v7, n- as K" � � � ,r -Y ., .r,: i,xX=b-'._ .. .�. M:..., t.,, r w,.:< s. ..=•.^R-dL.>L.�u,^:YYe»s eo�a,°�,. ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement v❑Other: Solar equipment,materials,labor,overhead,and the profit for the r r a 9 i , ,a'440- a „� work indicated on this application. 51 1-and 2-family dwelling ElCommercial/industrial Valuation: $ 15,500 ❑Accessory building El Multi-familyNumber of bedrooms: ❑Master builder ❑Other: Number of bathrooms: € w l, ',' ' :/. �1`"+ r ". "• . - Total number of floors: Job site address: 13612 SW Leah Ter New dwelling area: square feet City/State/ZIP: Tigard, OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solar-- Nicholas Blechman Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet Subdivision: Lot no.: Permit fees*are based on the value of the work performed. v Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the ';''',1 e r N r {{S>',t z -, work indicated on this application. t'3 ., Installation of a roof-mounted 12.30kW PV System Valuation: $ Existing building area: square feet New building area: square feet .e LJ - ;r� ,�,x °ram * { +.s.e a Al; �t ,��t:r, .•� 1+ t ,.���; ,� ��, z t e" Number of stories: Name:Nicholas Blechman Type of construction: Address: 13612 SW Leah Ter Occupancy groups: City/State/ZIP: Tigard, OR 97224 Existing: Phone: ( ( 503 459-1338 Fax:( ) j New: A1L� '.;, . . Cl, PF s' 3 el Business name:Sunpath Services c � "" jgf ,,rt, Contact name: Maggie Ludden Structural plan review fee(or deposit): Address: 9978 SW Arctic Dr FLS plan review fee(if applicable): City/State/ZIP:Beaverton,OR 97005 Total fees due upon application: Phone:(907 ) 792-9290 Fax::( ) Amount received: .44 ".4, E-mail: maggie@sunpathservices.com - ' * . . ,'w , 'v , . Commercial and residential prescriptive installation of '`w . :` s�.6, ,! k . -^ e `_.V L-� k,.. io ,,X,:, : `08 j roof-top mounted PhotoVoltaic Solar Panel System. Business name:Sun path Services Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 9978 SW Arctic Dr Solar Installation Specialty Code checklist. City/State/ZIP: Beaverton, OR 97005 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(907 )792-9290 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:235715 2Total fee due upon application: $201.60 Atithot7Zrtl stgtmlttl : �$\ This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Maggie Ludden Date: 10/31/23 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPennitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Electrical Permit Application RECEIVE • rtla OFFICE USE ONLY City of Tigard 0 C T 3 1 Received . 11 13125 SW Hall Blvd.,Tigard,OR 97223 2023 Date/B : yU Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/B : Related Permit#: T t G A R D Inspection Line: 503.639.4175 CITY OF TIGARD Ready Date/By: Jugs: El See Page 2 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental Information TYPE OF WORK : ' PLAN REVIEW :, ❑New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition IN Other: Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. El 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds l4,000 ❑Commercial-use agricmunral amps for all other installations. buildings. ❑Multi-family ❑Master builder ❑ Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ,.., ❑Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 13612 SW Leah Ter 100HP or more. ❑"A","E","l-2", `l-3", City/State/ZIP: Tigard, OR 97224 ❑Six or more residential units. occupancy. 0 Recreational vehicle parks. ❑Health-care facilities. Suite/bldg./apt.#: Project name: Solar-- Nicholas Blechman ❑Hazardous locations. ❑Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE. Orky Description I Qty. I Each I Total I New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168.54 4 Ea.add'1500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK - " Limited energy,residential above 75.00 2 Installation of a roof-mounted 12.30kW PV System Limited(with abovenergy,sq.m ft.).)-family residential(with above sq.ft.) 75.00 2 Renewable Energy ❑ See Page 2 "PRO TY"O R " . f ©="TEN T Services or feeders installation,alteration,and/or relocation Name:Nicholas Blechman 200 amps or less 100.70 2 Address: 13612 SW Leah Ter 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, OR 97224 601 amps to 1,000 amps 301.04 2 Phone:((503))459-1338 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: nickblec@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 APPLICANTI Branch circuits—.newt;alteration,or extension,per panel Q'CONT PEt,SON A.Fee for branch circuits with Business name:Sunpath Services above service or feeder fee, 7.42 2 each branch circuit Contact nameMaggie Ludden B.Fee for branch circuits without service or feeder fee,first Address: 9978 SW Arctic Dr branch circuit 56.18 2 City/State/ZIP:Beaverton,OR 97005 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(907 ) 792-9290 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:maggie@sunpathservices.com Reconnect only 67.84 2 CONTRACTOR a Pump or irrigation circle 67.84 2 Business name:Sunpath Services Sign or outline lighting 67.84 2 Address:9978 SW Arctic Dr Signal circuit(s)or limited-energy 0 See Page 2 2 panel,alteration,or extension. City/State/ZIP:Beaverton,OR 97005 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(907) 792-9290 Fax:( ) Investigation(1 hr min) 90.00/hr Email:maggie@su n pathservi ces.co rry71 Iv, /1(3 j i Industrial plant(1 hr min) 78.18/hr JInspections for which no fee is CCB Lic.:235715 Electrical Lic.:C LRS I Suprv.Lic.: 11,Z L R/1 specifically listed(Y2 hr min) 90.00/hr ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: O" fl4.. Subtotal: Print name:Jake Hoskins Date:1 O 31 23 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Maggie Ludden Date: 10/31/23 days after it has been accepted as complete. * Number of inspections allowed per permit. 1:\Building\Permits 1ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 4404615T(11/05/COM/WEB 'MSW. b6Mh R i x City11111 of Tigard ge ,, g Building Division ®CT3 13125 SW Hall Blvd,Tigard,OR 97223 CITY OF TIOA,j; Phone: 503.718.2439 Fax: 503.598.1960 BUILDING T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 13612 SW Leah Ter City: Tigard Zip:97224 Owner's Name: Nicholas Blechman Date: 10/31/23 Contractor's Name: Sunpath Services CCB #:235715 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? Q No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ✓❑ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than �✓ Yes the prescriptive path. above ❑ No 1 I:Building/Forms/PhotoVoltaic-Checklist02-01-1 I.docx Is the construction material wood and does El Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. El Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑r Yes with Section 305.4(3) of If"Yes", qualifies for Elthe 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofmg material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max.two layers the prescriptive path. El of composition shingle. Is the roof mounted ❑� Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:Building/Fonns/PhotoVoltaic-Checklist02-01-11.docx i 1 ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for D Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of n If"Yes", qualifies for fastener? I I Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2"thickness, n Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 1:/Building/Forms/PhotoV oltaic-Checkli st02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: R EC410AA PURE Listing Agency: U L 61730 4 I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx