Permit (3) 114 CITY OF TIGARD MASTER PERMIT �° COMMUNITY DEVELOPMENT Permit#: MST2023-00486 Date Issued: 11/14/2023 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S109DB03600 Jurisdiction: Tigard Site address: 13018 SW HAZELCREST WAY Subdivision: SUMMIT RIDGE Lot: 74 Project: Smith Project Description: Rooftop solar PV system 10.66 kW with 200 amp service and(2)circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $10,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 2 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other Y Other Description: Rooftop solar array 10.66 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: SMITH,STUART UNITY ELECTRICAL SERVICE LLC Required Items and Reports(Conditions) 13018 SW HAZELCREST WAY 15715 NE 42ND ST TIGARD,OR 97224 VANCOUVER,WA 98682 PHONE: PHONE: 971-379-7380 FAX: Total Fees: $480.59 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9-nnl-nnln rhrn nAR Qc9-nnl-nnon v nhfnin a nnnv of the nilce nr riircnt nncetinne to ni Inv-.by nollinn Rill 919 10A7 nr i Ann �1.19/911AA Issued By: Permittee Signature: ���/ _ t Call 50 . 39.4175 by 7:00 a.m.for the next available inspection ate. This permit card shall kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE 1 SE ONLN Received l 1 VU I1,()I rkP M�1I/A)U /t�1 r 8t0 City of Tigard h Received Permit No.: (J(J!� 4 13125 SW Hall Blvd.,Tigard,OR 97223 �?FIECEIV�U. plan Review 25 Phone: 503.718.2439 Fax: 503.598.1960 Date/By: 7 Other Permit: I I t,^,I;t> Inspection Line: 503.639.4175 /0�TOGA*�}te Ready/By: Jaris: ® See Page 2 for Internet: www.tigard-or.gov Uf I 1 l�o i led/Method: l ' 'AP 111 n� Supplemental Information BUILDING DIVi •I ' TYPE OF WORK REQUIRED DATAI I-. 2-FAMILY DWELLING ❑New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. [-:-.1 1-and 2-family dwelling II]Commercial/industrial Valuation: $ 10,000.00 ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SI&E DiFORMATION AND LOCATION Total number of floors: Job site address: 13018 SW crest Way New dwelling area: square feet City/State/ZIP: Tigard,Oregon 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Smith Residence Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: 1 Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: 2S109DB03600 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 10.66kW Solar Roof Mount Installation Valuation: $ Existing building area: square feet New building area: square feet 0 PROPERTY OWNER 0 TENANT Number of stories: Name: Stuart Smith Type of construction: Address: 13018 SW Hazlecrest Way Occupancy groups: City/State/ZIP: Tigard,Oregon 97224 Existing: Phone:( ) 503-240-7971 Fax:( ) New: 0 APPLICANT © CONTACT PERSON BUILDING PERMIT FEES* Business name:Unity Electrica Service LLC � aieesekeJula) Contact name: Clayton Tarkalson Structural plan review fee(or deposit): Address: 15715 NE 42nd street FLS plan review fee(if applicable): Total fees due upon application: City/State/ZIP: Vancouver WA 98682 Phone:( ) 9713561593 Fax::( ) Amount received: E-mail: permitting@unity-solar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM PEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name: UNITY ELECTRICAL SERVICE LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 15715 NE 42nd street Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver WA 98682 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( ) 9713561593 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 234553 Total fee due upon application: $201.60 Authorized signature: ,!C ' This permit application expires if a permit is not obtained I �b41u) within 180 days after it has been accepted as complete. Print name: L. 4. - Date: 7/17/23 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\P ts\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application I Y roR oli lcL i sh:Oyt, Received (•A i City of Tigard Permit#: y,` ,i •vJ ry`� 13125 SW Hall Blvd.,Ti ard,OR 97223 SEP 2 0 2�� ev g Phone: 503.718.2439 Fax: 503.598.1960 DatePlanDateRevBy:iew Related Permit#: Inspection Line: 503.639.4175 CITY OF TIraAI� eady Date/By: Juris: See Page 2 for II l„1 R l Internet: www.tigard-or.goV ohfied/Method: Supplemental Information - BUILDING©IVISI* , - , . . PLAN REVIEW ❑New construction Ad dition/alteration/replacemen Please check att that apply(submit Z sets of plans w/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. � ' CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. �.l 1-and 2-family dwellin ❑Commercial/industrial 0 Accessory building tens to ground,or exceeds la,000 ❑Commercial-use agdcuttnrat amps for all other installations. buildings. 0 Multi-family ❑Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived 0 Addition of new motor load of system. Job#: Job site address: 13018 SW Hazlecrest Way 100HP or more. ❑"A","E","t-2","1-3 City/State/ZIP: Tigard,Oregon 97224 ❑Six or more residential units. occupancy. ❑Health-care facilities. ❑Recreational vehicle pazks. Suite/bldg./apt.#: Project name: Smith Residence ❑Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCRED' LE Description I Qty. I Each I Total I New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 10.66kW Solar Roof Mount Installation (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑ See Page 2 El OWNER © TENANT " Services or feeders installation,alteration,and/or relocation Name: Stuart Smith 200 amps or less 1 100.70 2 Address: 13018 SW Hazlecrest Way 201 amps to 400 amps 133.56 2 Tigard,Oregon 97224 401 amps to 600 amps 200.34 2 , City/State/ZIP: 9 9 601 amps to 1,000 amps 301.04 2 Phone:( ) 503-260-7971 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: stuart.r.smith@icloud.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signatfu • Date: 401 amps to 599 amps 168.54 2 C Awl,� ' EttCONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: UNITY ELECTRICAL SERVICE LLC above service or feeder fee, 2 each branch circuit 7.42 2 Contact name: Clayton Tarkalson B.Fee for branch circuits without Address:15715 NE 42nd street service or feeder fee,first 56.18 2 branch circuit City/State/ZIP:Vancouver WA 98682 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( ) 971-379-7380 Fax: :( ) Each manufactured or modular 67.84 2 Email: permitting@unity-solar.com dwelling,service and/or feeder Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: UNITY ELECTRICAL SERVICE LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 15715 NE 42nd street panel,alteration,or extension. ❑ See Page 2 2 City/State/ZIP: Vancouver WA 98682 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( ) 971-379-7380 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr min) 78.18/hr Email: permitting@unity-solar.com Inspections for which no fee is 90.00/hr CCB Lic.: 234553 Electrical Lic.: C1599 Suprv.Lic.:4619S specifically listed(%hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: ‘a-....---,---,---', Subtotal: Print name: Daniel Broughton Date: 09/14/2023 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: t! tL/(ei. aBIL Date: 09/14/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC Permit pp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB EleFtfical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCRED[Ttl Description I Dry, I Each ] Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ A• udio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: E Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ H• eating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ri O• ther: Each additional inspection is charged at an hourly(1 hr min) 66.25/hr i Inspections for which no fee is 90.00/hr specifically listed('/hr min) COMMERCIAL.WORK ONLY: ELECTRICAL PERMIT FEES Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems n B• oiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation n F• ire Alarm Installation ❑ HVAC ❑ Instrumentation n Intercom and Paging Systems n L• andscape Irrigation Control* ❑ M• edical n N• urse Calls n O• utdoor Landscape Lighting* ❑ P• rotective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Budding\Permits\ELC PermitApp ELR_ERE.doc Rev 06/17/2015 W1'1u1,3•M\,3 City of Tigard 114 IN w Building Division 13125 SW Hall Blvd,Tigard,OR 97223 RECEIVED Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 SEP 2 0 2023 www.tigard-or.gov CITY OF TIGARD BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 13018 SW Hazlecrest Way City: Tigard,Oregon Zip: 97224 Owner's Name: Stuart Smith Date: 8/17/2023 Contractor's Name: Smart Solar Energy Co CCB #: 234657 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation [ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? C No ) OSSC or ORSC for design requirements. Is the wind exposure C❑ Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes C Yes) the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for above OW the prescriptive path. ❑ No 1,, I:Building/Forms/Photo Voltaic-Checklist02-01-I 1.docx Is the construction material wood and does C❑ Yes Type of the constructionqualifyIf"Yes", qualifies for Construction ❑ No the prescriptive path. as"conventional light frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? ❑ If"Yes", qualifies for Nominal lumber. Yes ) the prescriptive path. ❑ No Is the combined weight CI] Yes of the PV modules and - If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation ■ layout in accordance If"Yes", qualifies for with Section 305.4(3) of the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal layer If roofing material is Roofing Check the type of Esingle of woodone of the three types material roofing materialshingle/shake checked, qualifies for Max.two layers the prescriptive path. ❑ of composition shingle. Is the roof mounted E Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 1:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to 24 inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, 1$ inches qualifies for the prescriptive path. Minimum #10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? El Yes the prescriptive path. n No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof (I Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/Photo Voltaic-Checkl ist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: REC410AA PURE Listing Agency: UL61730 4 I:Building/Forms/Photo Voltaic-Checklist02-01-11.docx