Loading...
Permit (14) f 1CITY OF TIGARD MASTER PERMIT I . ' COMMUNITY DEVELOPMENT Permit#: MST2023-00561 Date Issued: 12/13/2023 T I i.;A R I7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106DD11300 Jurisdiction: Tigard Site address: 13638 SW RIVER TERRACE BLVD Subdivision: RIVER TERRACE TOWN CENTER Lot: 111 Project: River Terrace Town Center, Lot 111 Project Description: New attached dwelling(1 of 5)units. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 136 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 34 Bathrooms: 3 Second: 725 sf Garage: 588 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 731 sf Right: 3 Detectors: Total: 1592 sf Value: $312,058.32 Rear: 3 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Storm Sewer: 100 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: Catch Basins: 0 100 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All l Ecompasing: Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1592 Owner: Contractor: Required Items and Reports(Conditions) AG EHC II(NWHM)MULTI STATE 2 LLC TNHC OREGON LLC 1 Ersn Cntrl 503-639-4175 BY THE NEW HOME COMPANY INC 15231 LAGUNA CANYON ROAD 2 Fire Rated Conditions BY KAWANAMI,MARK SUITE 250 15231 LAGUNA CANYON RD STE IRVINE,CA 92618 3 Fire Sprinklers Required 250 PHONE: PHONE: 503-312-6213 FAX: Total Fees: $17,444.73 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance wit proved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTI . Oreg law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Qc9-nni_nnl n thrrn 1 A QA n1-nnQn n may nhtain a rnnv of tha n doc nr rlirart ni lactinnc to ill mu-.h,rallinnn Ang 717 10A7n,'r'11 A ''nn 9 9l4A Issued By Permittee Signature: SQ.e Q�p't\(.4A Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential i‘i 'f(7, ... ,.. v FOR OFFic'1: l SE()NIA Cityof Tigard Received / [-� 2 g f` i �; -4- 111 i Y blV 0 k�ti/�j Permit No.: a�71 J� 5/9( 41 13125 SW Hall Blvd.,Tigard,OR 9 22'3- .� " Date/By:: Od C Phone: 503.718.2439 Fax: 503. 6 Plan Review � ( /� J GI arlDateB t 1 ' 1/ `� Other Permit: 61l"�Z�3 -oU310'` TIC. .R p Inspection Line: 503.639.4175 V I!l�'r ii�J Date Ready/By: J HI See Page 4 for Internet: www.tigard-or.gov Notified/Method1/1,94 PIP Supplemental information F,yna.rli l•P,n,-t TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ID New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 3.L ❑ 1-and 2-family dwelling El Commercial/industrial Valuation: $1 0 l�rt?) ElAccessory building ❑■ Multi-family Number of bedrooms: 3 ❑Master builder ❑Other: Number of bathrooms: '3 JOB SITE INFORMATION AND LOCATION Total number of floors: 3 1.-1 t) Job site address:13638 SW River Terrace Blvd New dwelling area: 1 592 square feet 1 31 City/State/ZIP:Sherwood/OR/97140 Garage/carport area: 588 square feet 25— Suite/bldg./apt.no.:2 Project name:River Terrace Town Center Covered porch area: square feet 13(0 Cross street/directions to job site: Deck area: 9/8 square feet SW Jean Lot rise rd 6t k 1 square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision:River Terrace I Lot no.:111 Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.:parcel no:2S1060003300 equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Requesting Deferred SDC fees Valuation: $ Existing building area: square feet New building area: square feet 1k PROPERTY OWNER 0 TENANT Number of stories: Name:TNHC OREGON LLC Type of construction: Address:15231 Laguna Canyon RD STE 250 Occupancy p y groups: City/State/ZIP:Irine/CA/92618 Existing: Phone:(503)310-7571 Fax:( ) � APPLICANT New: 0 CONTACT PERSON BUILDING PERMIT FEES* Business name:TNHC OREGON LLC crleo.cerelertofeeschedule) Contact name:Frank Sandoval Structural plan review fee(or deposit): Address:15455 NW Greenbrier Parkway Suite 240 FLS plan review fee(if applicable): City/State/ZIP:Beaverton/OR/97006 Total fees due upon application: Phone:(503) 310-7571 Fax::( ) Amount received: E-mail:fsandoval@nwhm.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of Cis roof-top mounted Photo Voltaic Solar Panel System. Business name:TNHC OREGON LLC Submit two(2)sets of roof plan with connection details Address:15231 Laguna Canyon RD STE 250 and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. City/State/ZIP:Irvine/CA/92618 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)310-7571 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:241108 _ Total fee due upon application: $201.60 Authorized signature: -.*- ........111.111: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Frank Sandoval Date: 10/iqt /202 3 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPennitApp.doe 01/25/2023 440-4613T(11/02/COM/WEB) Mechanical Permit Applicaf CEIV 1012 01 FICL I SE(1y►.1 City of Tigard Received 1 Date/By: Permit No.: ,` trjltin IN • 13125 SW Hall Blvd.,Tigard,OR 97223 OCT 9 2023 t� r'. t i Phone: 503.718.2439 Fax: 503.598.1960 Plan Review i I t,A R D Inspection Line: 503.639.4175 Date/By: Other Permit: Internet: www.tigard-or.gov CI Date Ready/By: Juris: See Page 2 for TY OF TIGARD Notified/Method: Supplemental Information BUILDING DIVISION TYPE OF WORK CO R I ,EE*,SCl1IlPULE�-USE,C1► CKr $T Mechanical permit fees*are based on the value of the work ®New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. CATR#R! OP C+CNSTRIJC"[ION Value:$ ®1-and 2-family dwellin g ❑Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family ❑Master builder 0 Other: Description Qty. Ea. Total JOB Smt INFOR114ATfON AND LOCATION Heating/cooling: Air conditioning 1 46.75 Job site address:13638 SW River Terrace blvd - Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Sherwood OR 97140 Furnace 100,000+BTU(ducts/vents) 1 54.91 Suite/bldg./apt.no.: Project name:River Terrace Town Center Heat pump 61.06 Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 SW Jean Louise rd Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision:River Terrace Town Center Lot no.:111 Other: 23.32 Other fuel appliances: Tax map/parcel no.:2s 1060003300 Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 1 33.39 Flue vent for water heater or gas NEW HOME CONSTRUCTION fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 is PROPERTY OWNER 0 TENANT Other: 23.32 Environmental exhaust and ventilation: Name:TNHC OREGON LLC Range hood/other kitchen Address:15231 Laguna Canyon Rd STE 250 equipment 33.39 Clothes dryer exhaust 33.39 City/State/ZIP:Irvine CA 92618 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)310-7571 Fax:( ) Attic/crawlspace fans 23.32 10 APPLICANT 0 CONTACT PERSON , Other: 23.32 Business name:TNHC OREGON LLC Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Frank Sandoval Furnace,etc. Address:15455 NW Greenbrier Parkway#240 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Beaverton OR 97006 Water heater Phone:(503)310-7571 Fax::( ) Fireplace Range E-mail:fandoval@nwhm.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:Pro Heating and Cooling,INC Other: Address:4200 NW Leisy rd MECRANI Subtotal City/State/ZIP:Hillsboro, OR 97124 Minimum permit fee($90.00) Phone:(971)205 4989 Fax:( ) Plan review(25%of permit fee) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE /� �ei This permit application expires if a permit is not obtained within 180 ��C.!( D days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date:3/17/2023 I:\Building\Permits\MEC PermitApp_040113.doc 440-4617T(11/02/COM/WEB) Electrical Permit Application I tt)R c)rh1ti,i',h:(1N1.1 City of Tigard Received •t_ ^ 13125 S W Hall Blvd.,Tigard,OR 97223 l C T 19 2023 Date/By: Permit#: 1�`tA.l US % Phone: 503.718.2439 Fax: 503.598.1960 plan Review 1 Date/By: Related Permit g: l i + Inspection Line: 503.639.4175 Date/By: June:Internet: www.tigard-or.gov CITY OF TiGARG Ready Notified/Method: S See Page 2for BUILDING ®IVISIO upplemenml Information TYPE OF WORK 41 J PLAN REVIEW ®New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Demolition0 Other: Service or feeder 400 amps or more ❑Building over three stories. CA EGORY OF CONSTRUCTION where the available fault current 0 Marinas and boatyards. exceeds 10,000 amps at 150 volts or 0 Floating buildings. 0:1 I-and 2-family dwelling 0 Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑Multi family ❑Master builder Other:0amps for all other installations. buildings, JOB SITE INFORMATION AND LOCATION 0 Fire PAR 0 largInser of 15d derived A or ❑Emergency system. larger separately Job#: I Job site address: 13638 SW River Terrace blvd ❑Addition of new motor load of system. IOOHPormore. ❑"A""E""i_2""I3" City/State/ZIP: Sherwood/OR/97140 ❑Six or more residential units. occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldgJapt.#: I Project name: RTTC ❑Hazardous locations. 0 Supply voltage for more than Cross street/directions to job Site: ❑Service or feeder 600 amps or more. 600 volts nominal. FEE SCHEDULE SW Jean Louise rd Description i �,, I Each i Total i Subdivision: River Terrace Town Center New residential single-or multi-family dwelling unit. Lot#:111 Includes attached garage. Tax map/parcel 4: 2S 1060003300 1,000 sq.ft.or Less 168.54 4 DESCRIPTION OF WORK •ited sq.ft ode portion 33.92 1 Limited energy,residential NEW HOME CONSTRUCTION (with above sq.ft.) 75.00 2 Limited energy,multi-family residential(with above sq.ft.) 75.00 2 l PROPERTY OWNER I ❑ TENANT Renewable Energy ❑ See Page 2 Name: THNC OREGON LLC Services or feeders installation,alteration,and/or relocation 200 amps or less 100.70 2 Address: 15231 Laguna Canyon Rd STE 250 201 amps to400amps 133.56 2 City/State/ZIP: Irvine CA 92618 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:(503)310-7571 i Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: Fsandoval@newhomeeo.com Owner installation:This installation is bein made ro relocation g on p perty that I own wfiieh is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 Ii3 APPLICANT i © CONTACT PERSON Branch circuits—new,alteration,or extension,per panel Business name: THNC OREGON LLC A.Fee for branch circuits with above service or feeder fee, Contact name: Frank Sandoval each branch circuit 742 2 B.Fee for branch circuits without service or feeder fee,first Address: 15455 NW Greenbrier Parkway#240 56.18 branch circuit 2 City/State/ZIP: Beaverton OR 97006 Each add'l branch circuit 7.42 2 Phone:(503)310-7571 Miscellaneous(service or feeder not included) Fax::( ) Each manufactured or modular Email: Fsandoval@newhomeco.com dwelling,service and/or feeder 67.84 2 CONTRACTOR Reconnect only 67.84 2 Pump or Business name:Development Northwest Inc., DBA Wolcott Electrical lightingSignorroutlinenle 67.84 2 67.84 2 Address:1075 W Historic Columbia River Hwy Signal circuit(s)or limited-energy panel,alteration,or extension. 0 See Page 2 2 City/State/ZIP:Troutdale, OR, 97060 Each additional inspection over allowable in any of the above (503)$53-9420 I Fax:( ) Additional inspection(1 lir min) 66.25/hr Phone: Investigation(1 hr min) 90.00/hr Email:MWOLCOTT@WOLCOTT.PRO Industrial plant(1 hr min) 78.18/hr CCB Lic.: Inspections for which no fee is 112220 Electrical Lic.:C 1272 I Suprv.Lie.:5782S specifically listed(t4 hr min) 90•00/hr Suprv.Electrician signature,required:"��. ELECTRICAL:PERMIT FEES b<. «,,._,,,, , Subtotal: Print name:David Campbell I Date:10/12/2023 0 Plan Review Required(25%of permit fee): /� State surcharge(12%of permit fee): Authorized signature: 2 TOTAL PERMIT FEE: Print name:Malachi J. Wolcott 10/12/2023 This permit application expires if a permit is not obtained within I80 I Date: J days after it has been accepted as complete. t:tBuilding�PermitslELC_PemutA ' Number of inspections allowed per permit PP_ELa ERE.doe Rev 06/17/2015 440-4615T(t 1/05/COM/WEB • Plumbing Permit Application Building Fixtures RECEIVED MN (►l,rl( I' I I. ()NIA City of Tigard Received ^ tit .t tl&\ � , Date/By` Permit No.:V\�J[1, 11.. 13t25 SW Hall Blvd.,Tigard,OR 97223 al Phone: 503.718,2439 Fax: St . .19#09 2023 Plan Review Date/By: Other Permit No.: l I l A R l) Inspection Line: 503.639.4175 Date Read/B Internet: www.tigard-or.gov 7 y y mrig. See Page 2 for I Iry A g-1r1 Notified/Method: Supplemental information TYPE I �.tA IlJ G'DIVISION tEEk SCHEDULE Ia New construction 0 Demolition For special information use cllecklisf. Description i Qty. I Ea, I Total ❑Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(I)bath 312.70 ICI 1-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 1 437.78 ❑Accessory building SFR(3)bath 500,32 ❑Multi-family ❑Master builderEach additional bath/kitchen 25,02 0 Other: Fire sprinkler( sq,ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 13638 SW River I errace blvd Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18.76City/State/ZIP: Sherwood/OR/97140 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt no.: ( Project name: RTTC Manufactured home utilities 50.03 Cross street/directions to job site: SW Jean Louise rd Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.:_) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.:i) Page 2 Subdivision: River Terrace Town Center I Lot no.: 111 Fixture or item: Tax map/parcel no.: 2s1060003300 Backflow preventer 31.27 DESCUTPTIQN OF WORK Backwater valve 12.51 New Home Construction Clothes washer 25.02 Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 IV novERTy OAR` ( Q TENANT Expansion tank 12.51 Name: TNHC OREGON LLC Fixture/sewer cap 25.02 Address: 15231 Laguna Canyon Rd STE 250 Floor drain/floor sink/hub 25.02 Garbage disposal 25.02 City/State/ZIP: Irvine CA 92618 Hose bib 25.02 Phone:(503)310-7571 Fax:( ) Ice maker 12.51 DO APPLICANT CICONTACT PERSON Interceptor/grease trap 25.02 Business name: THNC OREGON LLC Medical gas(value:$_) Page 2 Contact name: Primer 12.51 Frank Sandoval Roof drain(commercial) 12.51 Address: 15455 NW Greenbrier Parkway#240 Sink/basin/lavatory 25.02 City/State/ZIP: Beaverton OR 97006 Solar units(potable water) 62.54 Phone:(503)310-7571 Fax::( ) Tub/shower/shower pan I2.51 E-mail: Urinal 25.02 CONTRACTOR Water closet 25.02 Water heater 37.52 Business name:Wolcott Plumbing Water piping/DWV 56.29 Address:1075 West Historic Columbia River Hwy Other: 25.02 city/State/ZIP:Troutdale OR. 97060 Subtotal Phone:( 503-667-1781 Fax:( ) Minimum permit fee: $72.50 CCB Lie.:112220 I Plumbing Lic.no.:26824 PB Plan review(25%of permit fee) f ! State surcharge(12TOTAL f fee) Authorized signature: A ,/s�^`�_ VVV�"�3" TOTAL PERMIT FEE Print name:Mark Baleme Date:10/12/2023 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. °Fee methodology set by Tri-County Building Industry Service Board. I:U3uilding\Permits1PLMU-PermilApp.doc 10/01/09 440-46I6T(10/02/COM/WEE) F-.., a III _ ° Building Division One & Two-Family Dwelling 1UaRD Fees Checklist PERMIT INFORMATION:�DS.� 1 Application Date - FEE VERSION �Q 1t ZZ's p�v� 2 Permit#: - — - Plan #: F. p2 b Floors: Valuation: t Covered Porch: Basement 31tiOn-11, Bedrooms: 3 Deck: q e: 1st Floor V'r io WC (toilets) 3 Deck Cover: 1 S 2nd Floor 25 Lavatories t ' Patio Cover 3rd Floor -7 Tub/shower 2 Accessory Struct. .._---- R-3 Total l S Laundry Tray Water Heater 1 / Gas /eillk Garage 3S Exhaust Vents L4 Gas Flue Vents Total for Elec. Z I gaib Backflow Prey. urnace Heat Pump AC # for Electrical BBQ „-- -_ Gas Fireplace �� #Fuel Lines 3 FEES: Description: Fee Applies: Fee Entered: DC Prov Revw: Planning Info Proc/Arch: Lg$2.00 (over 11x17) Li0 o o t. &e e l y �-r-c ` A`.V Info Proc/Arch: Sm $.50 (up to 11x17) L 1 Metro CET: Residential Use School CET: District: Tigard CET: Admin t/" Tigard CET: ODHCS Tigard CET: AH 1./"— Electrical Permit: Permit Fee: t.----- Limited Energy: s. 12% State Surcharge ✓' Mech. Permit: Permit Fee: 12% State Surcharge Plumbing Permit: Permit Fee: 12% State Surcharge f' Erosion Control: w/Permit- Ping I:\Building\Forms\ResPlanCheckFees_Dec2022_AA.doc 12/21/22 Page 1 RECEIVED City of Tigard UC! 19 2023 " COMMUNITY DEVELOPMENT DEPARTMENT CITY OF TIGARD Building Permit Review - Residential BUILDING DIVISION TIGARD Building Permit #: J ?_ 7,3 -Od Sto Site Address: 1363R SW River Terrace Blvd Verified in Accela Project Name: RT Town Center, Building y Lot/Unit#: 111 Proposal: New attached dwelling (1 of 5) Zone: RESC C C Housing Type: ❑ SFR(❑Single Detached 0 Duplex 0 Triplex 0 ADU),owhouse ECottage Cluster 0 CYU OQuad 0 Other Required Site Plan Elements: 0 3 copies of site plan on max 11x17" O Drawn to standard scale ❑ R..tairi J 1.CZS, J1 le/ ee election • North arrow ❑ Street and site trees shown / labeled m Site address, project name, lot # turity O Street names (N/A for SFR) O Applicant name and phone # 0-Get+rtyard rcctanglc dimcncioneel-(i#applicable) O Lot and setback dimensions ❑ILAIJIJI ly Jll ULLUl cJ & I,,VIUIJ.S.. Utility locations &easements O Footprint of new structure and FFE 0 Property corner elevations O Sidewalk/driveway dimensioned , O Lot area and lot coverage percentage 0 Erosion control Required Elevation Plan Elements: (For SFR: calcs needed only on street-facing) Summary table with calculations for: O Drawn to standard scale 0 Total façade area ❑ Building height dimensioned 0 Total window and door area Facade dimensioned O Windows and doors dimensioned Alley load Required Floor Plan Elements: (Not required for SFR) 0 Summary table that includes 0 Each story dimensioned 0 Total floor area O Each story floor area calculated 0 Floor area per story Planning Review The following standards have been met: Setbacks f1'Front: 8'/12' Rear: 3' (alley)Side: 3' Min/Max Street Side: 8' / Garage: 3' (alley) Height 0 Max. Height: 45' Proposed Height: 34' O Yes 0 N/A Landscape *Per PDR, landscape % is taken as for all rowhouses as a total, not per lot 0 Yes 0 N/A Screening (Quad only) 0 Yes ❑ N/A % Window Coverage 24.7% for entire Building 4 ❑ Yes 0 N/A Garage (SFR Only) Parking (Other Res) O Yes 0 N/A Entrance (SFR, Rowhouse, Quad only) *Faces street, porch min 48sf, width min 6ft 0 Yes 0 N/A Other building design standards (Rowhouse only) ❑ Yes 0 N/A Accessory Structure Standards ❑ Yes 0 No Qualifying pre-existing unit exempt from standards (Cottage unit only) Additional standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads: O Yes 0 N/A Unit Count: 5 O Yes 0 N/A Lot Width and Size *15ft wide min O Yes ❑ N/A Pathway *Paved access connecting entrance to sidewalk in Tract M Ad ' onal standards for Courtyard Units and Cottage Clusters only: ❑ Yes ❑ it Area: ❑ Yes 0 N/A Floor r story) ❑ Yes ❑ N/A Courtyard O Yes ❑ N/A Fence ❑ Yes 0 No 1N/A Clean Water Services - Service Provider Letter (lot platted prior to 9/10/1995) ❑ Yes 0 No EN/A Public Facilities Improvement (PFI) Permit: Required: ❑ Yes ❑ No Applied For: 0 Yes 0 No, stop intake El Sensitive Lands: 0 Yes El No o Main Land Use Case #s: PDR2021-00004 o Conditions met 0 Applicant notified of land use expiration date: Permits by 1/31/25. Final by 1/31/27 Approved By Planning: _ Date: 10/19/23 Notes Revision 1: ❑ Ap red ❑ Not Approved Date: Revision 2: ❑ A roved ❑ Not Approved Date: Building Permit Submittal Original Submittal Date: t011'113 Site Plans #: 3 Building Plans #: 3 Building Permit #: , J'Building pelnit # entered on page 1 Workflow Routing: 4 Planning raf Engineering Zr Permit Coordinator 0 Building Workflow Sign-off: K Sign-off for Planning (include notes from planning review) Route Documents: F'Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. r Building: original permit application, site plans, building plans, engineer and beam calculations and trust details, if applicable, etc. Permit Technician: Date: koill M Notes: Engineering Review ❑ PFI Permit: **Slope at building pad: O ok o¢ [0-Conditions met prior to issuance of permit 'Easements (encroachments) per engineering conditions of approval and plat k'Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes Assess Water Quantity Fee in-lieu: ❑ Yes o LIDA Facility on lot: 0 Yes No Add Fee: ❑ Yes ❑ No *final Plat Recorded ❑ NOT Approved: Date: Notes: Approved By Engineering: Date: /0/2_3 Revision 1: 0 Approv d 0 Not Approved Date: Revision 2: ❑ Approved ❑ Not Approved Date: Permit Coordinator Review Conditions met prior to permit issuance ❑ Approved, NOT Released: Date notified applicant: ENG Revisions Required:4 Date notified applicant: SDC Exemption: 0 Applied for LI Received does not apply rSDC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A Tigard Trans SDC: Yes ❑ N/A E Deferred Parks SDC: Q Yes 0 N/A Deferred LIDA ❑ Yes 74f1 N/A r OK to Issue/Approved by Permit Coordinator: Date: ` \ ' \ -7:_s Revision 1: 0 Approved ❑ Not Approved Date: Revision 2: 0 Approved 0 Not Approved Date: City of Tigard ■ COMMUNITY DEVELOPMENT DEPARTMENT 'IN : . r 1 G Ito River Terrace Building Permit Review Addendum Building Permit #: Mc5Tm3 - 00S(p Site Address: 13638 SW River Terrace Blvd Project Name: RT Town Center, Building ? " Lot #: 111 (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review of River Terrace Plan District Design Standards (18.640.070.1): Is the project subject to the plan district design standards?0 Yes ❑ No 1.Articulation: a minimum of 1 element per each street-facing facade that has 30-60 ft. of frontage.An additional element required for lots with over 60 ft. of street frontage shall be provided every 30 ft. Porch min. 5 ft. deep Balcony w/ access 2 Window Projection Vertical Wall Offset a Gabled dormer ft. deep min. 2ft., 5 ft.wide min. 2 ft., 6ft.wide 2. Eyes on the street: a minimum of 12%of each street facing facade must include windows or entrance doors. Percentage Shown: 24.7% for entire Building 4 3. Entrances:At least one entrance must meet both of the following standards: 0 Parallel to street,angle no more than 45° from street, 0 Max. 8 ft. setback from longest street-facing wall or open onto porch Entrance opens to a porch: fl Yes ❑ No If yes,all the following apply: 0 25 sq.ft.min. O One street facing entry 0 12 ft.max.roof above floor of porch 01 5 ft.depth min. 0 30%min.porch roof coverage 4. Detailed Design:All buildings shall include a min. of five of the following elements on all street-facing facades: O Covered porch min. 5 ft.wide x 5 ft. deep ❑ Recessed entry area min. 5 ft.wide x 2 ft. deep O Wall offset min. 16 inches ❑ Dormer min.4 ft.wide Z] Roof eave min. 12 inch projection 0 Roof offset min.of 2 ft. ❑ Roof shingles either tile or wood 0 Gable,hip or gambrel roof design ❑ Roof pitch oriented south min. 500 sq. ft. ❑ Horizontal lap siding min. 3-7 inches wide ❑ Accent siding min. 40%of street facade 0 Window trim min. 2 1/2"wide by 5/8"deep ❑ Window recess min. 3 inches for all street facing ❑ Bay window min. 5 ft.wide by 2 ft. deep ❑ Balcony min. 5 ft.wide x 3 ft. deep with inside access ❑ Attached garage is 35%or less of street facade . rages and Carports:May face the front or side lot line on a corner lot. Setbacks. No closer to front *de lot line,than longest street-facing wall. ❑ Yes ❑ No. If No (Check one): ❑ May extend up to 5 ft. t e is a covered front porch and garage does not extend beyond the front porch. ❑ May extend up to 5 ft.where the e is part of a two-story building and there is a window at the second story above the garage that faces the street with a ' area of 12 sq.ft. Width: (Check one) ❑ 12-foot-wide garage door ❑ ax. of street facade ❑ 50%max. of street facade with 7 detailed design elements Notes: Approved By Planning: r_e"?....,--_-- Date: 10/19/23 I:\Bui I ding\Forms\B I dgPermi tRv wRE S_RT_121417.do cx