Loading...
Permit (9) illCITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2023-00616 Date Issued: 12/20/2023 Tt G A 11,D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S111AA13400 Jurisdiction: Tigard Site address: 8891 SW INEZ ST Subdivision: IRMA DELL BUTTERFIELD Lot: 12 Project: Zamora Project Description: Rooftop solar PV system 14.000 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $7,848.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach. 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Rootfop solar array 14.000 kW. Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: ZAMORA,DIEGO FERNEY CHARA TML INTERNATIONAL LLC Required Items and Reports(Conditions) GODOY,SINDY ANGELICA LENIS 6405 E MILL PLAIN BLVD 8891 SW INEZ ST VANCOUVER,WA 98661 TIGARD,OR 97224 PHONE PHONE: 800-364-0470 FAX: Total Fees: $351.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requir s you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9-nnl-Mln+hen. P oc9-nfl1 anon vnr, in env of+hm mime nr r+irmr+nnme+inne+n ni intr.h„,. iiinn FM 919 10117 nr 1 Ann'17 7'2AA 1� fib 0Issued By: �;!�'r ! c'wt `Permittee Signature: /� Call 503.639.417 by 7:00 a.m.for the next available inspection date. This permit card shall be ke n a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE USE ONLY City of Tigard RECEIVE Received ��Plan Review c � �''��. Permit No.: +t 13125 SW Hall Blvd.,Tigard,OR 97223 DateB �'r h ��s ' it 7 ,-. =;, .) '>.6,.t cc Phone: 503.718.2439 Fax: 503.598.196011111 DEC 6 Date/By: V II Z3 Other Permit. TI GARI] Inspection Line: 503.639.4175 2023 Date ReadyBy: n .r is ® See Page 2 for Internet: www.tigard-or.gov Notified/Method: V V •�1 'li I Supplemental Information .� OFT] IVYA,t,/,64t,< .r 9 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement UI Other:Solar equipment,materials,labor,overhead,and the profit for the z CATEGORY of Gb1�TSl�I Y � ,� �, work indicated on this application. . ., ._i �.... . _ �; , >.:.r. �n7-...k„-Vfl t• : .,, � a Valuation: $ ❑■ 1-and 2-family dwelling IDCommercial/industrial 7848 ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SITiE INFORMATION A`11D LOCATIONTotal number of floors: Job site address:8891 SW Inez St New dwelling area: square feet City/State/ZIP:Tigard OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solarinstall-DCharaZamora Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCE4i-,ESECIIECKLISt' Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.:W469776 Indicate the value(rounded to the nearest dollar)of all equipment.materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of 35 solar panels in 4 arrays on a roof-mounted 14.000kW PV System Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: Name:Diego Chara Zamora Type of construction: Address:8891 SW Inez St Occupancy groups: City/State/ZIP:Tigard OR 97224 Existing: Phone:( )503-536-5620 Fax:( ) New: U,APPLICANT a CONTACT PERSON BUILDING PERMIT FEES* (Please.reJer 10 fee schedule) Business name:TML International LLC Structural plan review fee(or deposit): Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable): Address:6405 E Mill Plain Blvd Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Phone:( )(360)326-0650 Fax: :( ) Amount received: E-mail:permit@infinitysolarusa.com PHO OVOLTAICSOLARPANELsyyTEAI+ EF * Commercial and residential prescriptive installation of . -..... ,. 'CONTRACTOR .. . roof-top mounted PhotoVoltaic Solar Panel System. Business name:TML International LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )3603260650 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.:223690 Total fee due upon application: $201.60 Authorized signature: �/ This permit application expires if a permit is not obtained Z7�2,�"5141-Zi Ti within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:Mary Dinsmore-Smi Date:12/4/2023 Service Board. l:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY Cityo Tigard .. /., RECEI g DateB /?;r� L1s" >'. 41, -. Permit#: �+1A: ..•r f <, ';" : a 13125 SW Hall Blvd.,Tigard,OR 97223 rlL R $ Phone: 503.718.2439 Fax: 503.598.1960 D C C 6 21 IltenBy:eview Related Permit#: Inspection Line: 503.639.4175 Ready Date/By: Juris ® See Page 2 for F I L A R 13 Internet: www.tigard-or.gov *p led/Method: CITY QTC�'TIG• 2' y Supplemental Information `R Ire e ,. %TYPE O 1� ' ' r I s1 r t ,r s es. :.„,�,�.� �... .. .., .,x`,. ..,� .:.. .. �=� ., ..t.? yes»� �..� � �a�" .` •.� .. ., ` �€. .:. Please check all that apply(submit 2 sets of plans w/items checked):❑New construction ID Addition/alteration/replacement 0 Demolition 0 Other: ❑Service or feeder 400 amps or more ❑Building over three stories. where the available fault current ❑Marinas and boatyards. t„r .o,: :f In :; " _ exceeds 10,000 amps at 150 volts or 0 Floating buildings. Q 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑commercial-use agricultural amps for all other installations. buildings. ❑Multi-family 0 Master builder ❑Other: 0 Fire Pump.p. 0 Installation of 150 KVA or ryH": M . ,; ; J° "130 c :.. "• .,. . :':. ., t :'' .... -. ,,.. ❑Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address:8891 SW Inez St 100HP or more. ❑"A","E","1-z","1-3", ❑Six or more residential units. occupancy. City/State/ZIP:Tigard OR 97224 Recreational vehicle ❑Health-care facilities. ❑ parks. Suite/bldg./apt.#: Project name:Solarinstall-DCharaZamora ❑Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more 600 volts nominal Cross street/directions to job site: Description f Qty. I Each Total I�• New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#:W469776 Ea.add'l 500 sq.ft or portion 33.92 1 . . . ::: 1DESCRIP'flO (F WORK:.r=,. idai . .. - Limited energy,residential ( ith ab ft.) 75.00 2 Installation of 35 panels in 4 arrays on a roof-mounted 14.000kW PV system Limwited eneorgyve,sq mul. ti-family residential(with above sq.ft.) 75.00 2 Renewable Energy El See Page 2 PROPERTY'.OWNER 0 {TE(NTAN'l' Services or feeders installation,alteration,and/or relocation Name:Diego Chara Zamora 200 amps or less 100.70 2 Address:8891 SW Inez St 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard OR 97224 601 amps to 1,000 amps 301.04 2 Phone:( )503-536-5620 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:diegochara20@hotmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ■❑ APPLICANT CONTAC I' PERSON Branch circuits—new,alteration,or extension,Qer panel A.Fee for branch circuits with Business name:TML International LLC dba Infinity Solar USA above service or feeder fee, 7.42 2 each branch circuit Contact name:Mary Dinsmore-Smith B.Fee for branch circuits without service or feeder fee,first Address:6405 E Mill Plain Blvd 56.18 2 branch circuit City/State/ZIP:Vancouver WA 98661 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( )360-326-0650 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and or feeder Email:permit@infinitysolarusa.com Reconnect only 67.84 2 CO1 ''RAcTORi . . g a Pump or irrigation circle 67.84 2 Business name:TML International LLC dba Infinity Solar USA Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address:6405 E Mill Plain Blvd panel,alteration,or extension. ❑ See Page 2 2 Cit /State/ZIP: Each additional inspection over allowable in any of the above y Vancouver WA 98661 Additional inspection(l hr min) 66.25/hr Phone:( )360-326-0650 Fax: ( ) Investigation(1 hr min) 90.00/hr Email: Industrial plant(1 hr min) 78.18/hr permit@infinitysolarusa.eom Inspections for which no fee is specifically listed('2 hr min) 90 00/hr CCB Lic.:223690 Electrical Lic.:C1556 Suprv.Lic.:4434S }y( yr z-$ Suprv.Electrician signature,required: -t ietp. � Subtotal: Print name:Todd Rouse Date:12/4/2023 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: Df..,:a11.6,2,4._�'yy TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Mary Dinsmore mith Date:12/4/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. I.\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/i 7/2015 440-4615T(1 t/OS/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: �( >l ... e . Description I Qty. Each l Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(%z hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMI W s Subtotal Fee for each commercial system: $75.00 3' * Number of inspections allowedd (Enter on Page 1). per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations L\Building\Permits\ELCPermitAppELR_ERE.doc Rev 06/17/2015 City of Tigard 'i Building Division 13125 SW Hall Blvd,Tigard, OR 97223 RECEIVE Phone: 503.718.2439 Fax: 503.598.1960 D T I GARD Inspection Line: 503.639.4175 DEC 6 2Q23 www.tigard-or.gov CITY OF TIARD BUILDING DtV SON 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address:8891 SW Inez St City: Tigard Zip: 97224 Owner's Name:Diego Chara Zamora Date: 12/4/2023 Contractor's Name:TML International LLC dba Infinity Solar USA CCB #: 223690 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ❑■ No OSSC or ORSC for design requirements. El Is the wind exposure Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑■ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ❑ Yes the prescriptive path. above ❑ No 1 1:/Building/Forms/Photovoltaic-Checklist02-01-11.docx Is the construction material wood and does ❑■ Yes Type of If"Yes", qualifies for the construction qualify Construction as"conventional light 1-1No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. 0 Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight 0 Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation • layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for ❑ the 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑■ of composition shingle. Is the roof mounted ❑■ Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist02-0 1-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels If the width of the panel P Width of roofing is less than 18 inches, panels? 18 inches or less inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ❑ Yes the prescriptive path. surface. ❑ No 3 1`/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:Siolfab Model Number:S I L-400 HC+ Listing Agency: UL 61730 4 1:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx