Loading...
Permit (10) CITY OF TIGARD MASTER PERMIT N .._ . ' COMMUNITY DEVELOPMENT Permit#: MST2023-00555 Date Issued: 12/18/2023 T I[;A K D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106DD13000 Jurisdiction: Tigard Site address: 16675 SW JEAN LOUISE RD Subdivision: RIVER TERRACE TOWN CENTER Lot: 129 Project: River Terrace Town Center, Lot 129 Project Description: New attached dwelling(4 of 4)units. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 136 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 34 Bathrooms: 3 Second: 725 sf Garage: 588 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 731 sf Right: 3 Detectors: Total: 1592 sf Value: $312,058.32 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1592 Owner: Contractor: AG EHC II(NWHM)MULTI STATE 2 LLC TNHC OREGON LLC Required Items and Reports(Conditions) BY THE NEW HOME COMPANY INC 15231 LAGUNA CANYON ROAD 1 Ersn Cntrl 503-639-4175 BY KAWANAMI,MARK SUITE 250 2 Fire Rated Conditions 15231 LAGUNA CANYON RD STE IRVINE,CA 92618 3 Fire Sprinklers Required 250 PHONE: PHONE: 503-312-6213 FAX: Total Fees: $17,301.23 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR ac9_nni notn fhrnnnh •' •c9_nn1_nn- au nhtain a rnnv of tho rnlcc nr rlirort n,,octinnc to nI IN'..by rallinn an 3 TV>1QA7 nr I Ann 110 944A IPP Issued By: �!/J�r� Permittee Signature: U.. ta�1P kj U'r1• Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application©EC E IVE D Residential fill 10l4 orF►c I. ► S►:ON El City of Tigard OC f 1 8 2023 Da eB Receivd Permit No.: A s[2 fb -oa sS S 14 i 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ' -V 1 Other Permit: �7 Phone: 503.718.2439 Fax: 503.598.196Q�'I�OI=TIGARD Date/By: {� �� 'lo7j {� S 3i 1 1,,A RI) Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By: /�� y� J �: 0 See Page 4 for Internet: www.tigard-or.gov Notified/Method: `�/1 l to (/�'AIP `Q, Supplemental information TYPE OF WORK `' ---REQUIREDDATA 1-A D2-FAMILY LLII El New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF C•NSTRUCTIOIt work indicated on this application. �� El and 2-family dwelling IDCommercial/industrial Valuation: $1 ��, 64 Number of bedrooms: 3 CIAccessory building El Multi-family ID builder ❑Other: Number of bathrooms: ' JOB SITE INFORMATION AND LOCATION ,^ Total number of floors: 3 x) Job site address:16675 SW Jean Louise rd New dwelling area: 15592 square feet 3 i City/State/ZIP:Sherwood/OR/97140 Garage/carport area: 588 square feet 7 1$ Suite/bldg./apt.no.: Project name:River Terrace Town Center Covered porch area: square feet t �d Cross street/directions to job site: Deck area: 98 square feet SW River Terrace blvd 1 ( q� square feet REQUIRED DlATA1 10i1 L-V* EtXUST. Subdivision:River Terrace I Lot no.:129 Permit fees*are based on the value of the work performed. Tax map/parcel no.:parC@I no:2S1060003300 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORT{ work indicated on this application. Valuation: $ Requesting Deferred SDC fees Existing building area: square feet New building area: square feet PROPERTY'OWNER 0 TENANT Number of stories: Name:TNHC OREGON LLC Type of construction: Address:15231 Laguna Canyon RD STE 250 Occupancy groups: City/State/ZIP:Irvine/CA/92618 Existing: Phone:(503)310-7571 Fax:( ) New: iliAPPLICANT C3 CONTACT PERSON , ;'„ DIN PERMIT*SO!' - Business name:TNHC OREGON LLC fir` ° `" `� '� Structural plan review fee(or deposit): Contact name:Frank Sandoval FLS plan review fee(if applicable): Address:15455 NW Greenbrier Parkway Suite 240 Total fees due upon application: City/State/ZIP:Beaverton/OR/97006 Phone:(503)310-7571 Fax::( ) Amount received: E-mail:fandoval@nwhm.com P1It1TO`Y(I ,TAIC"SO R-PANELS"I'`I MFEES*" Commercial and residential prescriptive installation of TRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:TNHC OREGON LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:15231 Laguna Canyon RD STE 250 Solar Installation Specialty Code checklist. City/State/ZIP:Irvine/CA/92618 Permit Fee(includes plan review $180.00 and administrative fees): _ Phone:(503)310-7571 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:241108 Total fee due upon application: $201.60 Authorized signature: � ,/ This permit application expires if a permit is not obtained G within 180 days after it has been accepted as complete. Print name:Frank Sandoval Date: N/i$f 23 *Fee methodology set by Tri-County Building Industry Service Board. 1:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Mechanical Permit Anplicat CEIVE i of orr►ct: l sl.o,l.l City of Tigard Received Permit No.: II II 13125 SW Hall Blvd.,Tigard,OR 97223 C' y �I 1 g UC.I 8 2023 Plan Review _ Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: 1 1 Ci rt R I, Inspection Line: 503.639.4175 Date ReadyBy: Juris: 13 See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD NotiSed Method: Supplemental Information BUILDING DIVISION TYPE OF WORK ,CO. I.,I..nt'r: C OIX'-°SS ellECKUO'' Mechanical permit fees*are based on the value of the work ®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESI NT LEQUVM ` Ym sI ES* ® I-and 2-family dwelling 0 Commercial/industrial ❑Accessory building For special information use checklist 0 Multi-family ❑Master builder 0 Other: Description Qty. Ea. Total jos SITE INFORMATION Am) LOCATION Heating/cooling: Air conditioning 1 46.75 Job site address:16675 SW Jean Louise rd Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Sherwood OR 97140 Furnace 100,000+BTU(ducts/vents) 1 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:River Terrace Town Center Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or SW River Terrace blvd hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:River Terrace Town Center Lot no.: 129 Other fuel appliances: Tax map/parcel no.:2S 1060003300 Water heater 23.32 DLSC'IZIT30N Gas fireplace/insert 1 33.39 Flue vent for water heater or gas NEW HOME CONSTRUCTION fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 � PROPERTY OWNER Other: 23.32 0 TENANr Environmental exhaust and ventilation: Name:TNHC OREGON LLC Range hood/other kitchen 1 equipment 33.39 Address:15231 Laguna Canyon Rd STE 250 Clothes dryer exhaust 33.39 Single-duct exhaust(bathrooms, City/State/ZIP:Irvine CA 92618 toilet compartments,utility rooms) 23.32 Phone:(503810-7571 Fax:( ) Attic/crawlspace fans 23.32 Ii APPLICANT ❑ COACT PERSON Other: 23.32 Business name:TNHC OREGON LLC Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Frank Sandoval Furnace,etc. Adaress:15455 NW Greenbrier Parkway#240 Gas heat pumpWall/suspended/unitheater City/State/ZIP:Beaverton OR 97006 Water heater Phone:(503)310-7571 Fax::( ) Fireplace Range E-mail:fsandoval@nwhm.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:Pro Heating and Cooling, INC Other: ME I,h.L PERMIT FEES* Address:4200 NW Leisy rd Subtotal City/State/ZIP:Hillsboro, OR 97124 Minimum permit fee($90.00) - Plan review(25%of permit fee) Phone:(971)205 4989 Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: C—E � C * Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date:3/17/2023 I:\Building\Permits\MEC_PermitApp_040113.doc 440-4617r(I1/02/COM/WEB) Electrical Permit Applicat CEIVED Foli of ru i..l sr oyry City of Tigard (� 7 8 Received MS Ile.1'00 J&S 13125 SW Hall Blvd. Tigard,OR 972 Date By: Permit 1*', 29r 1 2023 Plan Review IN = Phone: 503.718.2439 Fax: 503.598.1 960C I Date By: Related Permit#: 1.1 a` n Inspection Line: 503.639.4175 CITY OF TIGARD Ready Date/By: 1 : I laSee Page 2 for Internet: www.tigard-or.gov Notified/Method; Supplemental Information TYPE OF BUILDING DIVISION PLAN REVIEW ®New construction ❑Addition/alteration/replacement Please cheek all that apply(submit 2 sets of plans w/items checked): ❑Demolition QtheT: 0 Service or feeder 400 amps or more 0 Building over three stories. where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ►/ 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural Multi-famil amps for all other installations. buildings. Y ❑Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system, larger separately derived Job#: Job site address:16675 SW Jean Louise rd DAddssioncsfriew motor toad of system. 100HPormore. ❑"A»'°E» •t_2»..i 3„ City/State/ZIP: Sherwood/OR/97140 ❑Six on more residential units. occupancy. ❑Health-care facilities. ❑Recreational vehicle parks. Suite/bldgJapt.#: Project name: RTTC ❑Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCh EDULE SW Jean Louise rd Dearaptiea I OtY. I Each I Total j New residential single-or multi-family dwelling unit. Subdivision: River Terrace Town Center Lot#:129 Includes attached garage. Tax map/parcel#: 2s1060003300 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential NEW HOME CONSTRUCTION (with above sq.R) 75.00 2 Limited energy,multi-family residential(with above sq.ft) 75.00 2 PROPERTY OWNER TENANT Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation Name: THNC OREGON LLC 200 amps or less 100.70 2 Address: 15231 Laguna Canyon Rd STE 250 2ol amps toaooamps 133.56 2 City/State/ZIP: Irvine CA 92618 401 amps tob00amps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:(503)310-7571 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: Fsandoval@newhomeco.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 cia APPLICANT 0 CONTACT PERSON Branch circuits—new,alteration,or extension, er panel THNC OREGON LLC A.Fee for branch circuits with Business name: above service or feeder fee, each branch circuit 7.42 2 Contact name: Frank Sandoval B.Fee for branch circuits without Address: 15455 NW Greenbrier Parkway#240 ranihcir feeder fee,first branch crcuit 56.18 2 b City/State/ZIP: Beaverton OR 97006 Each add'l branch circuit 7.42 2 Phone:( 310 7571 Miscellaneous(service or feeder not included) Fax::( ) Each manufactured or modular 67.84 Email: Fsandoval@newhomeco.com dwelling,service and/or feeder 2 Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Development Northwest Inc., DBA Wolcott Electrical Sign or outline lighting 67.84 2 Address:1075 W Historic Columbia River Hwy pinel,agnal leraionorlixiensienergy 0 �Page 2 2 panel,alteration,or extension. City/State/ZIP:Troutdale, OR, 97060 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503)853-9420 Fax:( ) Investigation(1 hr min) 90.00/hr Email:M WOLCOTT@WOLCQTT.PRO Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.:112220 Electrical Lic.:C 1272 Suprv.Lic.:5782S specifically listed(%hr min) 90.00/hr Suprv.Electrician signature,required:' i FT•FCTRICAL PERMIT FEES w.w. ..�.,..,,»s.. Subtotal: Print name:David Campbell Date:10/12/2023 0 Plan Review Required(25%of permit fee): �lt /� State surcharge(12%of permit fee): Authorized signature: '4.;, ? TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Malachi J. Wolcott Date:10/12/2023 days after it has been accepted as complete. ' Number of inspections allowed per permit I:\BuildinglPermitslELC_PernvtApp_ELR ERE.doc Rev 06/17t2015 440-4615T(I I/05/COMAVEB Plumbing Permit Applica rCEIVED Building Fixtures OC I l'oR 0141( 1,. I.sr, t)\i,1 1 8 2023 City of Tigard Date/BY: Permit No.: l511 liS.OOSSS i I3125 SW Hall Blvd.,Tigard,OR 97223 Datel6p: 1�J V Plan Review Phone: 503.718.2439 Fate: 503.0$ 6epF TIGARD Date/By: Other Permit No,: 1 1, it I,I) Inspection Line: 503.639.4175 BUILDING DIVISION ISIGN Date Ready/By: Saris: H See Page 2 for Internet: www.tigard-or.gov Notified/tvlethod: Supplemental Information TYPE OF WORK ''.FEE* SCHEDULE ®New construction 0 Demolition For special information use checklist. Description I Qty. I Ea. I Total ❑Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY>OF CONSTRUCTION SFR(I)bath 312.70 la 1-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 1 437.78 buildingSFR(3)bath 500.32 ❑Accessor y 0 Multi-family Each additional bath/kitchen 25.02 ❑Master builder 0 Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 16675 SW Jean Louise rd Catch basin or area drain 18.76 City/State/ZIP: Sherwood/OR/97140 Drywell,leach line,or trench drain 18.76 Footing drain(no.linear ft.:_) Page 2 Suite/bldg./apt.no.: l Project name: RTTC Manufactured home utilities 50.03 Cross street/directions to job site: SW River Terrace blvd Manholes 18.76 j Rain drain connector 18.76 Sanitary sewer(no.linear ft.:_) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: River Terrace Town Center I Lot no.: 129 Fixture or item: Tax map/parcel no.: 2s 1060003300 Backflow preventer 31.27 DESCRIPTION ON WORK Backwater valve 12.51 New Home Construction Clothes washer 25.02 Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 Ill PROPERTY OWNER: 1 ❑ I ENANT Expansion tank 12.51 Name: TNHC OREGON LLC Fixture/sewer cap 25.02 Address: 15231 Laguna Canyon Rd STE 250 Floor drain/floorsink/hub 25.02 Garbage disposal 25.02 City/State/ZiP: Irvine CA 92618 Hose bib 25.02 Phone:(503)310-7571 Fax:( ) Ice maker 12.51 Ca APPLICANT ®':CONTACT PERSON Interceptor/grease trap 25.02 Business name: THNC OREGON LLC Medical gas(value:$_) Page 2 Primer 12.51 Contact name: Frank Sandoval Roof drain(commercial) 12.51 Address: 15455 NW Greenbrier Parkway#240 Sink/basin/lavatory _ 25.02 City/State/ZIP: Beaverton OR 97006 Solar units(potable water) 62.54 Phone:(503)310-7571 Fax::( ) Tub/shower/shower pan 12.51 E-mail: Urinal 25.02 CONTRACTOR Water closet 25.02 Water heater 37.52 Business name:Wolcott Plumbing Water P i P mg/DWV 56.29 Address:1075 West Historic Columbia River Hwy Other: 25.02 City/State/ZIP:Troutdale OR. 97060 Subtotal Phone:( 503-667-1781 Fax:( ) Minimum permit fee: $72.50 CCB Lie.:112220 4 Plumbing Lic.no.:26824 PB Plan review (25%of permit fee) 4U State surcharge(12%of permit fee) Authorized signature: TOTAL PERMIT FEE Print name:Mark Baleme v Date:10/12/2023 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I:U3uiidi.g\Permits\PLMU-PermitApp.doc 10/at/09 440-4616T(10/02/COM/WaS) 7 ISli Building Division r.P I One & Two-Family Dwelling T 'GARD Fees Checklist PERMIT INFORMATION: Application Date - FEE VERSION --3-dty 2a23 Permit#: ryt5 Z Z3 a0 55 S Plan#: a^ 2 Floors: Valuation: $m1 On.32 Covered Porch: Basement Bedrooms: 3 Deck: (a I.CZ 1"Floor 2 WC (toilets) 3 Deck Cover: 1 �2 V 2nd Floor —7`2S— Lavatories ti Patio Cover 3'Floor Tub/shower 7. Accessory Struct. R-3 Total 1/-' Laundry Tray Water Heater ' / Gas ell Garage gS Exhaust Vents Gas Flue Vents - Total for Elec. 7- $b Backflow Prev. L 'MP)Heat Pump AC #„ for Electrical3 BBQ .— Gas Fireplace f� #Fuel Lines 3 FEES: Description: Fee Appli : Fee Entered: DC Prov Revw: Planning L Info Proc/Arch: Lg$2.00 (over 11x17) bill' qet v ,f rY ur►� Info Proc/Arch: Sm$.50 (up to 11x17) Z I Metro CET: Residential�se School CET: District: 1,, ,,c,P•ck i/ Tigard CET: Admin Tigard CET: ODHCS Tigard CET: AH ✓' Electrical Permit: Permit Fee: tV Limited Energy: it/ 12% State Surcharge Mech. Permit: Permit Fee: 12% State Surcharge Plumbing Permit: Permit Fee: 12% State Surcharge ‹/ Erosion Control: w/Permit-Ping 17 I:\Building\Forms\ResPlanCheckFees_Dec2022_AA.doc 12/21/22 Page 1 City of Tigard lig . " COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Review - Residential TIGARD Building Permit #: tirC7A&S-0,o7%3_OOSSS Site Address: -129645"SW Jean Louise Rd ®Verified in Accela Project Name: River Terrace Town Center Lot/unit #: Building 5 -129 Proposal: New Rowhouse Zone: C-C Housing Type: El SFR(El Single Detached El Duplex El Triplex❑ADU) ® Rowhouse❑Cottage Cluster El CYU ❑Quad El Other Required Site Plan Elements: X 3 copies of site plan on max 11x17" X Drawn to standard scale ❑ Retained trees, drip linc/ trcc protcction ® North arrow IX Street and site trees shown / labeled X Site address, project name, lot # E Table-calculating trcc canopy at maturity I@ Street names (N/A for SFR) EX Applicant name and phone # ❑ Courtyard rectanglc dimcnsioncd (if applicablc) X Lot and setback dimensions IX Vision clearance triangle O Existing structures &squarc footagc X Utility locations &easements X Footprint of new structure and FFE X Property corner elevations ® Sidewalk/driveway dimensioned ❑ LIDA (>1,000 sf di3turboncc) X Lot area and lot coverage percentage X Erosion control Required Elevation Plan Elements: (For SFR: calcs needed only on street-facing) Summary table with calculations for: X Drawn to standard scale ®Total facade area X Building height dimensioned X Total window and door area X Facade dimensioned IX Windows and doors dimensioned X Garage doors dimensioned Required Floor Plan Elements: (Not required for SFR) ® Summary table that includes ® Each story dimensioned M Total floor area I 1 Each story floor area calculated ® Floor area per story Planning Review The following standards have been met: Setbacks /Front:12' Rear: 0'or 20'if Side: 3' Min/Max Street Side: 8' / 20' Garage:3 or 20'if 8' Porch driveway parking provided onveway parking Height C!1 Max. Height: 45' Proposed Height: 34-0 7/8" provided ® Yes El N/A Landscape ❑ Yes ® N/A Screening (Quad only) ® Yes ❑ N/A % Window Coverage ® Yes ❑ N/A Garage (SFR Only) Parking (Other Res) ® Yes El N/A Entrance (SFR, Rowhouse, Quad only) © Yes ❑ N/A Other building design standards (Rowhouse only) ❑ Yes El N/A Accessory Structure Standards ❑ Yes El No Qualifying pre-existing unit exempt from standards (Cottage unit only) Additional standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads: Xl Yes 0 N/A Unit Count: 4 ® Yes El N/A Lot Width and Size l Yes 0 N/A Pathway Additional standards for Courtyard Units and Cottage Clusters only: ❑ Yes N/A Unit Area: ❑ Yes N/A Floor Area (per story) O Yes N/A Courtyard 10 Yes N/A Fence ❑ Yes ❑ No 1N/A Clean Water Services - Service Provider Letter (lot platted prior to 9/10/1995) O Yes 0 No MN/A Public Facilities Improvement (PFI) Permit: Required: ❑ Yes 0 No Applied For: ❑ Yes ❑ No, stop intake l Sensitive Lands: 0 Yes ® No PDR2021-00004 0 Main Land Use Case #s: 0 Conditions met o Applicant notified of land use expiration : Submit development plans by 1/31/25.Final Occupancy by 1/31/27 Approved By Planning: Date: 9/26/23 CO/tg/A_3 Notes Revision 1: 0 Approved 0 Not Approved Date: Revision 2: 0 Approved 0 Not Approved Date: Building Permit Submittal Original Submittal Date: tO I.S Iril Site Plans #: S Building Plans #: 3 Building Permit #: 'Building permit # entered on page 1 Workflow Routing: Planning J2'Engineering Permit Coordinator ,2--Building Workflow Sign-off: 0-Sign-off for Planning (include notes from planning review) Route Documents: ,Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. fd'Building: original permit application, site plans, building plans, engineer and beam calculations and trust details, if applicable, etc. Permit Technician: . 1-- Date: _ kO S Z(o 04 Notes: Engineering Review ❑ PFI Permit: ❑ Slope at building pad: % ❑ Conditions met prior to issuance of permit O Easements (encroachments) per engineering conditions of approval and plat ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: 0 Yes ❑ No Assess Water Quantity Fee in-lieu: 0 Yes 0 No LIDA Facility on lot: 0 Yes 0 No Add Fee: 0 Yes 0 No ❑ Final Plat Recorded ❑ NOT Approved: Date: Notes: C \ ' Approved By Engineering: b" )nA\ 6� ate: �• Z Revision 1: ❑ Approved 0 Not Approved _ Date: Revision 2: 0 Approved 0 Not Approved Date: Permit Coordinator Review Conditions met prior to permit issuance O Approved, NOT Released: Date notified applicant: O ENG Revisions Required: Date notified applicant: 4 SDC Exemption: 0 Applied for 0 Received 974oes not apply ?DC Fees Entered: Wash Co Trans Dev Tax: Yes 0 N/A Tigard Trans SDC: Yes 0 N/A Deferred Parks SDC: Yes 0 N/A i Deferred LIDA 0 Yes PJ/A K to Issue/Approved by Permit Coordinator: k Date: `1- lY`?5 Revision 1: 0 Approved ❑ Not Approved Date: Revision 2: 0 Approved 0 Not Approved Date: