Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (4)
1111 CITY OF TIGARD MASTER PERMIT 2 . . COMMUNITY DEVELOPMENT Permit#: MST2023-00567 TIC I:I) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 12/18/2023 . Parcel: 2S106DD13100 Jurisdiction: Tigard Site address: 16667 SW JEAN LOUISE RD Subdivision: RIVER TERRACE TOWN CENTER Lot: 130 Project: River Terrace Town Center, Lot 130 Project Description: New attached dwelling(1 of 4)units. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 136 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 34 Bathrooms: 3 Second: 725 sf Garage: 588 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 731 sf Right: 3 Detectors: Total: 1592 sf Value: $313,720.32 Rear: 3 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1592 Owner: Contractor: AG EHC II(NWHM)MULTI STATE 2 LLC TNHC OREGON LLC Required Items and Reports(Conditions) BY THE NEW HOME COMPANY INC 15231 LAGUNA CANYON ROAD 1 Ersn Cntrl 503-639-4175 BY KAWANAMI,MARK SUITE 250 2 Fire Rated Conditions 15231 LAGUNA CANYON RD STE IRVINE,CA 92618 3 Fire Sprinklers Required 250 PHONE: PHONE: 503-312-6213 FAX: Total Fees: $17,471.17 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTI . Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Qc9-nM-rnln thrnnn A Qc9_nn1-nn Vn,,may nhtain a rnnw of tha ndne nr riirart niioetinne to(lI INC by rallinn£I'1' 919 1QR7 nr 1 Ann TV>9Qdd Issued By: 1 Permittee Signature: Ste O }ItLlt 11 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application RECEIVED Residential OCT 25 2023 FOR OFFI( F FSF()NIA Received Q 2 permit No.: City of Tigard Date/By: 'O 1044.AP tAS1'A1/S.005191 13125 SW Hall Blvd.,Tigara,OR 97223 CITY OFT{GAR II Plan Review I,Iu A S t t t: b3-13 Phone: 503.718.2439 Fax: 503.598.1960 ate/By: Other Permit: BUILDING DIUISIII J is See Page 4 r T I G A R D Inspection Line: 503-or gov otie Notified/Method: : , v\ t . , *No \(n} I Supplemental Information Internet: wvvw.tigard-or. Notified/Method.CV ,bull 1 11t. PP T oil;'W REQUIREDD TA:1 2i Y D 'i i 0 New construction E Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other equipment,materials,labor,overhead,and the profit for the„ work indicated on this application. 13 ®i Valuation: $1 , ❑ 1-and 2-family dweling ❑Commercial/industrial Number of bedrooms: 3 ❑Accessory building El Multi-family ❑Master builder ❑Other: Number of bathrooms: r: iE1�+1 ,; TIf1�1�i ���Total number of floors: 3 tt • t�C�1�'�f)I'� Job site address:16667 SW Jean Louise Rd New dwelling area: 1592 square feet 7bl City/State/ZIP:Sherwood/OR/97140 Garage/carport area. 588 square feet 7).5 Suite/bldg./apt.no.: Project name:River Terrace Town Center Covered porch area: 50 square feet l Cross street/directions to job site: Deck area: 98 square feet SW River Terrace RIvd 35,15thatetelitteO square feet A4tettRtit#,ATSVOT*It*MOVSt!jOiSMIST: . Subdivision:River Terrace I Lot no.:130 Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.:parcel no: 2S1060003300 equipment,materials,labor,overhead,and the profit for the R io' work indicated on this application. Valuation: $ Requesting Deferred SDC fees Existing building area: square feet New building area: square feet Number of stories: Name:TNHC OREGON LLC Type of construction: Address:15231 Laguna Canyon RD STE 250 Occupancy groups: City/State/ZIP:Irvine/CA/92618 Existing: Phone:(503)310-7571 Fax:( ) New: it t , 0 CONTAt trtt. o fit mtz * #1tiAitt.Sosc.. :el 1 _ Business name:TNHC OREGON LLC • Structural plan review fee(or deposit): -�+ Contact name:Frank Sandoval FLS plan review fee(if applicable): Address:15455 NW Greenbrier Parkway Suite 240 Total fees due upon application: City/State/ZIP:Beaverton/OR/97006 Amount received: Phone:(503) 310-7571 Fax::( ) , E-mail: 'gaototovofsandoval@nwhmMfltnw .com O L ST FE Commercial and residential prescriptive installation of p. 6Jrl+iTRA CTOR roof-top mounted Photo Voltaic Solar Panel System. Business"name.TNHC OREGON LLC Submit two(2)sets of roof plan with connection details -2and fire department access,along with the 2010 Oregon Address:15231 Laguna Canyon RD STE 250 Solar Installation Specialty Code checklist. ---"' Cit /State/ZIP:Irvine/CA/92618 Permit Fee(includes plan review $180.00 Y and administrative fees): Phone:(503 )310-7571 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:241108 Total fee due upon application: $201.60 AulhtJrized This permit application expires if a permit is not obtained / within 180 days after it has been accepted as complete. Print name:Frank Sandoval Date: 10 f` 5/20Z *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(I 1/02/COM/WEB) Mechanical Permit Applica CEIV E D FOR OFFICE ISE ONLY City of Tigard Date/By:Received '` O 2023 Permit No.: V O V • 13125 SW Flail Blvd.,Tigard,OR 97223 Plan Review v7 t ' II Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: T I G AR D Inspection Line: 503.639.4175 CITY OF TIGARD Date Ready/By: Juris: 0 See Page 2 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental Information Mechanical permit based on the value of the work ®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ 1CAT ;OR1 OF b1+NISfRI'cT 101:I `.P f 'I�IFItilTO:14- N"Cfb" 1tiiI Yam *., ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description Qty. Ea. Total 3oB . : 1 ikA1C Heating/cooling: Air conditioning 1 46.75 Job site address:16667 SW JEAN LOUISE RD Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Sherwood OR 97140 Furnace 100,000+BTU(duets/vents) 1 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:River Terrace Town Center Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or SW RIVER TERRACE BLVD hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:River Terrace Town Center Lot no.:130 Other fuel appliances: Tax map/parcel no.:2S1060003300 Water heater 23.32 1kii 4'YC31t'[f ' Gas fireplace/insert 1 33.39 "' Flue vent for water heater or gas NEW HOME CONSTRUCTION fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 , to r 23.32 . Environmental exhaust an ven'a ion: Name:TNHC OREGON LLC Range hood/other kitchen equipment 1 33.39 Address:15231 Laguna Canyon Rd STE 250 Clothes dryer exhaust 33.39 . City/State/ZIP:Irvine CA 92618 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503 310-7571 Fax:( ) Attic/crawlspace fans 23.32 AfCAii ` .El )1tsio r. 23.32 Other: Fuel piping: Business name: TNHC OREGON LLC $14.15 for first four;$4.03 for each additional Contact name:Frank Sandoval Furnace,etc. Address:15455 NW Greenbrier Parkway#240 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Beaverton OR 97006 Water heater Phone:(503)310-7571 Fax: :( ) Fireplace Range E-mail:fsandoval@nwhm.com Barbecue :: T t4cr#R Clothes dryer(gas) Other Business name:Pro Heating and Cooling, INC f i Address:4200 NW Leisy rd Subtotal City/State/ZIP:Hillsboro, OR 97124 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(971 205 4989 Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: ( Z 444 d2 * Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date:3/17/2023 i.\Building\Permits\MEC_PermitApp_040113.doc 440-4617r(11/02/COM/WEB) Electrical Permit ApplicatI�oECEIVED FOR OFFICE tsr.ONLY Received ,`�j�/� (fir`r�� ilh " City of Tigard �CT 5e102`� Date/By Permit#:N` `•1 f� 1•Uu", 13125 SW Hall Blvd.,Tigard,OR 972 I [ •6 Plan Review 'rV J g' Phone. 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#: Inspection Line 503.639.4175 CITY OF TIGARD Ready Date/By: funs: fill See Page 2 for TIUARL? Internet: www.tigard-or.gov BUILDING DiVISIQI 6 Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ®New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. 0 Multi-family 0 Master builder ❑Other: ❑Fire pump. ❑installation of 150 KVA or JOB SITE INFORMATION AND LOCATION` 0 Emergency system. larger separately derived AdditiJob#: Job site address: 16667 SW Jean Louise Rd ❑1O0HP o re,motor load of system. 0HP or m moore. ❑"A","E","1-2","I-3", City/State/ZIP: Sherwood/ OR/ 97140 ❑S;xonnorefacresidential lities lunits occupancy. ❑Health-care facilities. 0 Recreational vehicle parks Suite/bldg./apt.#: Project name: RTTC 0 Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE SW River Terrace blvd Description I Qty. 1 Each I Total 1 New residential single-or multi-family dwelling unit. Subdivision: River Terrace Town Center Lot#:130 Includes attached garage. Tax map/parcel#: 2s1060003300 Ea. add'l0 sq.5 or less 168.54 4 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential NEW HOME CONSTRUCTION (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy 0 See Page 2 134 PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name: THNC OREGON LLC 200 amps or less 100.70 2 Address: 15231 Laguna Canyon Rd STE 250 201 amps to 400 amps 133.5E 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Irvine CA 92618 601 amps to1,000amps 301.04 2 Phone:(503)310-7571 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: Fsandoval©newhomeco.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel 12:1A.Fee for branch circuits with Business name: THNC OREGON LLC above service or feeder fee, 742 2 each branch circuit Contact name: Frank Sandoval B.Fee for branch circuits without Address: 15455 NW Greenbrier Parkway#240 service or feeder fee,first branch circuit 56.18 2 City/State/ZIP: Beaverton OR 97006 Each add'l branch circuit 7.42 2 - Miscellaneous(service or feeder not included) Phone:(503)310-7571 Fax::( ) Each manufactured or modular 67,84 2 Email: Fsandoval@newhomeco.com dwelling service and/or feeder Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Development Northwest Inc., DBA Wolcott Electrical Sign or outline lighting 67.84 ' 2 Signal circuit(s)or limited-energy ❑ See Page 2 2 Address:1075 W Historic Columbia River Hwy panel,alteration,or extension. City/State/ZIP:Troutdale, OR, 97060 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.251 hr Phone:(503)853-9420 Fax:( ) Investigation(1 hr min) 90.00/hr Email:M WOLCQTT@WOLCQTT,PRO Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lie.:112220 Electrical Lic.:C 1272 Suprv.Lic.:5782S specifically listed(m%hr min) 90.00/hr ELECTRICAL PERMIT PEES Suprv.Electrician signature,required •ter a� Subtotal: Print name:David Campbell Date:10/12/2023 0 Plan Review Required(25%of permit fee): 4 State surcharge(12%of permit fee): Authorized signature: 4 km TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within ISO Print name:Malachi J. Wolcott Date:10/12/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. IdBuilding\Permits\ELC_PerndtApp_ELR_ERE.doc Rev 06i17/2015 440-4615T(1 t/05/COM/WEB • Plumbing Permit ApplicatloEC I V Building Fixtures OCT 2 5 2021 FOR OFFICE, USE ON►,i' City of Tigard Received Date/B*y: Remit No.:IVISi ki V//12.4( I 1 J I II4 13125 SW Hall Blvd.,Tigard,OR 9 OF TIGARD Plan Review C Phone: 503.718.2439 Fak: 503� ILUING DIVISION DaleB Other Permit No, LLLJJ Y I'I G A R D Inspection Line: 503.639.4175 Date Ready/By: hurls: ® See Page 2 for Internet: wsvw tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction ❑Demolition For special information use checklist. Description i Qty- 1 Ea. I Total ❑Addition/alteration/replacement ❑Oilier: New I-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® I-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 1 437.78 SFR(3)bath 500.32 ❑Accessory building 0 Multi-family Each additional bath/kitchen 25.02 ❑Master builder 0 Other: Fire sprinkler( sq.ft) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 16667 SW Jean Louise Rd Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18.76 City/State/ZIP: Sherwood/OR/97140 Footing drain(no.linear ft.:_) Page 2 Suite/bldg./apt.no.: Project name: RTTC Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 SW River Terrace Blvd Rain drain connector 18.76 Sanitary sewer(no linear ft.._) Page 2 Storm sewer(no.linear II: ) Page 2 Water service(no.linear ft:_) Page 2 Subdivision: River Terrace Town Center I Lot no.: 130 Fixture or item: Tax map/parcel no.: 2s 1060003300 Backflow preventer 31.27 DESCRIPTION OF WO Backwater valve 12.51 New Home Construction Clotheswashcr 25.02 Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 b..t PROPERTY OWNER I El TENANT Expansion tank 12.51 Name: TNHC OREGON LLC Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address: 15231 Laguna Canyon Rd STE 250 Garbage disposal 25.02 City/State/ZIP: Irvine CA 92618 Hose bib 25.02 Phone:(503)310-7571 Fax:( ) Ice maker 12.51 ( I APPLICANT IX CONTACT PERSON Interceptor/grease trap 25.02 Business name: THNC OREGON LLC Medical gas(value:$_) Page 2 Primer 12.51 Contact name: Frank Sandoval Roof drain(commercial) 12.51 Address: 15455 NW Greenbrier Parkway#240 Sink/basin/lavatory 25.02 City/State/ZIP: Beaverton OR 97006 Solar units(potable water) 62.54 Phone:(503)310-7571 Fax::( ) Tub/shower/shower pan 12.51 E-mail: Urinal 25.02 Water closet 25.02 CONTRACFOR Water heater 37.52 Business name:Wolcott Plumbing Water piping/DWV 56.29 Address:1075 West Historic Columbia River Hwy Other: 25.02 City/State/ZIP:Troutdale OR. 97060 Subtotal Phone:( 503-667-1781 Fax:( ) Minimum permit fee: $72.50 112220 Plumbing 26824 PB Plan review (25%ofpennit fee) CCB Lie.: Lie.no.: State surcharge(12%of permit lee) Authorized signature: " - TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days Print name:Mark Baleme Date:10/12/2023 after it has been accepted as complete. °Fee methodology set by Tri-County Building Industry Service Board. I\Building\Permits\PLMU-PermitApp.doc 10/01/09 440-4616T(I0/02/CONUA'EB) Building Division ( D- b :ill . One & Two-Family Dwelling T i G ARD u i'�('/Y� - W Fees Checklist PERMIT INFORMATION: Application Date - FEE VERSION J‘) `(/ 2-ti23 Vr..51-1,023 - CO 5(0 7 Permit#: —— —"' Plan #: F-aa DI Floors: Valuation: „.-5t-7) 7d3 r'52-- Covered Porch: Basement .—_----- Bedrooms: Deck: 9C+ 1-Floor 1 2/ _ WC (toilets) Deck Cover: 9 cb 2"d Floor - 5 Lavatories u Patio Cover 3`d Floor ---73 I Tub/shower Z Accessory Struct. R-3 Total l Se')Z Laundry Tray Water Heater V / Gas / lec Garage 5SC3 Exhaust Vents ti Gas Flue Vents ..-----' Total for Elec. 2- 1 (a O Backflow Prey. 4111:111Heat Pump /(AC, # for Electrical 3 BBQ ,...---- Gas Fireplace VI-� #Fuel Lines FEES: Description: Fee Applies: Fee Entered: DC Prov Revw: Planning V Info Proc/Arch: Lg$2.00 (over 11x17) Li 0 >. j -,.`rS Info Proc/Arch: Sm $.50 (up to 11x17) L 2-7 ,- D ri < Y\ 5 g-A- Metro CET: Residential Use t Z School CET: District: 1 tg Tigard CET: Admin t - Tigard CET: ODHCS Tigard CET: AH l - Electrical Permit: Permit Fee: i ' Limited Energy: 12% State Surcharge Mech. Permit: Permit Fee: 12% State Surcharge , / Plumbing Permit: Permit Fee: L/". 12% State Surcharge Erosion Control: w/Permit-Ping I:\Building\Forms\ResPlanCheckFees_Dec2022_AA.d0c 12/21/22 Page 1 City of Tigard S . COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Review - Residential TIGARD Building Permit #: ►t ' W T4'QOSb1 Site Address: 16667 SW Jean Louise Rd m Verified in Accela Project Name: RT Town Center, Building 6 Lot/Unit #: 130 Proposal: New attached dwelling (1 of 4) Zone: C-C Housing Type: ❑ SFR(0 Single Detached ❑ Duplex El Triplex 0 ADU)m Rowhouse❑Cottage Cluster❑CYU ❑Quad El Other Required Site Plan Elements: m 3 copies of site plan on max 11x17" m Drawn to standard scale ❑ Rclau led h ccs, Ji iN lint/ h cc ,1 election m North arrow m Street and site trees shown / labeled m Site address, project name, lot # iRirpoiskwaelowietikErgmtweviesoeirreirrMaturity m Street names (N/A for SFR) m Applicant name and phone # El Courtyard rectangle dimensioned (if applicable) m Lot and setback dimensions c'o'-'-co t-'319 ❑ 1y u.�u�G, oyuai.. tiLOLUy‘. m Utility locations &easements m Footprint of new structure and FFE m Property corner elevations m Sidewalk/driveway dimensioned m Lot area and lot coverage percentage m Erosion control Required Elevation Plan Elements: (For SFR: calcs needed only on street-facing) Summary table with calculations for: m Drawn to standard scale m Total façade area m Building height dimensioned m Total window and door area m Façade dimensioned m Windows and doors dimensioned Alley load Required Floor Plan Elements: (Not required for SFR) m Summary table that includes m Each story dimensioned m Total floor area m Each story floor area calculated m Floor area per story Planning Review The following standards have been met: Setbacks m Front: 8'/12' Rear: 3' (alley)Side: 3' Min/Max Street Side: 8' / Garage: 3' (alley) Height m Max. Height: 45' Proposed Height: 33.5' m Yes ❑ N/A Landscape *Per PDR, landscape % is taken as for all rowhouses as a total, not per lot 0 Yes m N/A Screening (Quad only) m Yes 0 N/A % Window Coverage 18% for entire Building 6 El Yes m N/A Garage (SFR Only) Parking (Other Res) m Yes ❑ N/A Entrance (SFR, Rowhouse, Quad only) *Faces street, porch min 48sf, width min 6ft m Yes 0 N/A Other building design standards (Rowhouse only) ❑ Yes m N/A Accessory Structure Standards ❑ Yes m No Qualifying pre-existing unit exempt from standards (Cottage unit only) Additional standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads: m Yes El N/A Unit Count: 4 m Yes ❑ N/A Lot Width and Size *15ft wide min m Yes El N/A Pathway 'onal standards for Courtyard Units and Cottage Clusters only: ❑ Yes ❑ it Area: ❑ Yes El N/A Floor r story) El Yes 0 N/A Courtyard El Yes El N/A Fence ❑ Yes ❑ No ON/A Clean Water Services - Service Provider Letter (lot platted prior to 9/10/1995) 0 Yes ❑ No ON/A Public Facilities Improvement (PFI) Permit: Required: ❑ Yes ❑ No Applied For: ❑ Yes ❑ No, stop intake O Sensitive Lands: ❑ Yes 0 No O Main Land Use Case #s: PDR2021-00004 0 Conditions met 0 Applicant notified of land use expiration date: Permits by 1/31/25. Final by 1/31/27 Approved By Planning: Date: 10/24/23 Notes Revision 1: ❑ Ap ded ❑ Not Approved Date: Revision 2: 0 A roved ❑ Not Approved Date: Building Permit Submittal Original Submittal Date: V11/61/5 Site Plans #: Building Plans #: 3 Building Permit #: 1 "Building permit # entered on page 1 Workflow Routing: e/Planning "Engineering IN/Permit Coordinator IN4uilding Workflow Sign-off: 2'Sign-off for Planning (include notes from planning review) Route Documents: ?''Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. l "Building: original permit application, site plans, building plans, engineer and beam calculations and trust details, if applicable, etc. 1 t 1'�ti3 Permit Technician: r n ,n�� Date: Notes: Engineering Review ❑ PFI Permit: VSlope at building pad: 21 1/,,9 F2"Conditions met prior to issuance of permit reEasements (encroachments) per engineering conditions of approval and plat s .f Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes lid''No Assess Water Quantity Fee in-lieu: ❑ Yes g'No LIDA Facility on lot: ❑ Yes '1 No Add Fee: ❑ Yes 0 No 'inal Plat Recorded • ❑ NOT Approved: Date: Notes: Approved By Engineering: Date: /////.2.---3 Revision 1: 0 Approved ❑ Not proved Date: Revision 2: ❑ Approved ❑ Not Approved _ Date: P-rmit Coordinator Review 'Conditions met prior to permit issuance ❑ Approved, NOT Released: Date notified applicant: DING Revisions Required: Date notified applicant: liciDC Exemption: 0 Applied for 0 Received Does not apply L.�DC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A ( Tigard Trans SDC: Yes ❑ N/A Deferred Parks SDC: Yes 0 N/A ❑ eferred LIDA ❑ Yes L/A - ? OK to Issue/Approved by Permit Coordinator: Date: I - (02`Z3 Revision 1: ❑ Approved 0 Not Approved Date: Revision 2: 0 Approved 0 Not Approved Date: