Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (8)
CITY OF TIGARD MASTER PERMIT -"' Permit#: MST2023-00614 ' COMMUNITY DEVELOPMENT Date Issued: 01/08/2024 T f t; AR T`f 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106DD12100 Jurisdiction: Tigard Site address: 13732 SW RIVER TERRACE BLVD Subdivision: RIVER TERRACE TOWN CENTER Lot: 120 Project: River Terrace Town Center, Lot 120 Project Description: New attached dwelling(5 of 5)units. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 136 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 34 Bathrooms: 3 Second: 725 sf Garage: 588 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 731 sf Right: 3 Detectors: Total: 1592 sf Value: $313,720.32 Rear: 3 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add''500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Ecompasing: Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1592 Owner: Contractor: Required Items and Reports(Conditions) AG EHC II(NWHM)MULTI STATE 2 LLC TNHC OREGON LLC BY THE NEW HOME COMPANY INC 15231 LAGUNA CANYON ROAD 1 Ersn Cntrl 503-639-4175 BY KAWANAMI,MARK SUITE 250 2 Fire Rated Conditions 15231 LAGUNA CANYON RD STE IRVINE,CA 92618 3 Fire Sprinklers Required 250 PHONE: PHONE: 503-312-6213 FAX: Total Fees: $17,327.67 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENT N: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9-nn1-nn1 n thrni in A Qc ..nn 1-nnon i i,., in a.rnntr of tha name nr rtirart ni iacfinnc to nl e it by rairinn cn3 919 10R7 nr 1 Ann 3't9 91dd Issued By: Permittee Signature: 1 e'e P l I c .l-f, 6 0 / Call 503.63A. 175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the iob site at the time of each inspection. , Building Permit Application._ Residential ED FOR OFFICE USE()NIA Received City of Tigard NOV 2 g Iti I , RP Permit No.:M 2 I4 2023 Date/By S'l�.0 3 Gbb . 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review �� ��"" L�V� III ■ I k Other Permit:(��{ M 3• v Phone: 503.718.2439 Fax 503.598.19 0 Date/By: I�/ "� t PPS, J�V�W1/ TIGARD Inspection Line: 503.639.4175 CITY OF TIGARD DateReady/By: • Juris: gi See Page 4 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method , 1 'l o t p 1‘ _ Supplemental Information of WO tK: :.. : REQUIRED DikTA I- ,ND: 1F:AiMIILY 111"W LL 1 El New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the T Y of M ' >tZ o work indicated on this application " El1-and 2-family dwelling ❑Commercial/industrial Valuation: $ 3 i 3I t Number of bedrooms: 3 IIIAccessory building 0 Multi-family ❑Master builder ❑Other: Number of bathrooms: Total number of floors: 3 #3 olt1t A„„„„ . l �t I Ai'ltllUN �{) Job site address:13732 SW River Terrace Blvd New dwelling area: 1592 square feet 73 City/State/ZIP:Sherwood/OR/97140 Garage/carport area: 588 square feet 7a' Suite/bldg./apt.no.: Project name:River Terrace Town Center Covered porch area: 50 square feet 13 oP Cross street/directions to job site: Deck area: 98 square feet -SW Jean Louise Rd tytvt6.964Noar 1 FJ square feet Q DATA: sc � Subdivision:River Terrace I Lot no.:120 Permit fees*are based on the value of the work performed. Tax map/parcel no.:parcel no: 2S1060003300 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the D�� OF':WO work indicated on this application. Valuation: $ Requesting Deferred SDC fees Existing building area: square feet New building area: square feet )l T r! R Q 11"EN IT Number of stories: Name:TNHC OREGON LLC Type of construction: Address:15231 Laguna Canyon RD STE 250 Occupancy groups: City/State/ZIP:Irvine/CA/92618 Existing: Phone:(503)310-7571 Fax:( ) New: A 1LI ANT 0 ACT �) -!:9,11116,vitoisotritatratsconemiros Business name:TNHC OREGON LLC . ... Structural plan review fee(or deposit): Contact name:Frank Sandoval FLS plan review fee(if applicable): Address:15455 NW Greenbrier Parkway Suite 240 Total fees due upon application: City/State/ZIP:Beaverton/OR/97006 received: Phone:(503) 310-7571 Fax::( ) Amount r E-mail fandoval@nwhm com OY p- ptvwl N(WIr1,l ,v Wwt 1 II , ' t ,A E ', N I El1 S ,,,,,,,, ,, Commercial and residential prescriptive installation of .;, roof top mounted Photovoltaic Solar Panel System. Business name:TNHC OREGON LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:15231 Laguna Canyon RD STE 250 Solar Installation Specialty Code checklist. Fee(includes plan review $180.00 City/State/ZIP:Irvine/CA/92618 Permit and administrative fees): Phone:(503 )310-7571 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:241108 Total fee due upon application: $201.60 MtU ed igttttttttr . V,) J This permit application expires if a permit is not obtained I/�/t� within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:Frank Sand I �, ate: 1 l• 29 •2A)- Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Mechanical Permit ApplicaRECEIVE—D FOR OFFICE USE ONUN' Cityof Tigard Received �C/l/►�, .00\o1kk 14 ill Date/By: Permit No.: J 1 b 13125 SW Hall Blvd.,Tigard,OR 97223 NOV 2023 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: T I G A R D Inspection Line: 503.639.4175 CITY OF TIGPthL) Date Ready/By: Juris: iii See Page 2 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental information ' " pE.W(l� M :: Mechanical permit fees*arc based on the value of the work ®New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ ONSTRUC`"1 IO ❑ 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist. V Multi-family 0 Master builder ❑Other: Description Qty. Ea. Total i(l.B SITE 31I AND ATTON 1 Heating/cooling: Air conditioning 46.75 Job site address: 13732 SW River Terrace Blvd Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Sherwood OR 97140 Furnace 100,000+BTU(ducts/vents) 1 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:River Terrace Town Center Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or SW Jean Louise Road hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:River Terrace Town Center Lot no.: 120 Other fuel appliances: Tax map/parcel no.:251060003300 Water heater 23.32 ': n Oi F,ov fireplace/insert 33.39 Gas freplace/'t nsert Flue vent for water heater or gas NEW HOME CONSTRUCTION fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 '1.R Environmental exhaust and ventilation: Name:TNHC OREGON LLC Rangehood/otherkitchen equipment 1 33.39 Address:15231 Laguna Canyon Rd STE 250 Clothes dryer exhaust 1 33.39 Cit /State/ZIP:Irvine CA 92618 Single-duct exhaust(bathrooms, Al 23.32 Y toilet compartments,utility rooms) Phone:(503)310-7571 Fax:( ) Attic/crawlspace fans 23.32 �� 23.32 („(o�`.t1.� S? ... Other:piping: Fuel i ing: Business name:TNHC OREGON LLC $14.15 for first four;$4.03 for each additional Contact name:Frank Sandoval Furnace,etc. 1 Address:15455 NW Greenbrier Parkway#240 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Beaverton OR 97006 Water heater Phone:(503)310-7571 Fax: :( ) Fireplace Range E-mail:fsandoval@nwhm.com Barbecue 0QR Clothes dryer(gas) Business name: Pro Heating and Cooling, INC Other: tA11►1 Address:4200 NW Leisy rd Subtotal City/State/ZIP:Hillsboro' OR 97124 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(971)205 4989 Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: C T7u.2a42- * Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date:3/17/2023 C\Building\Permits\MEC PermitApp 040113.doc 440-4617T(I 1/02/COM/WEB) RECENT D Electrical Permit Application FOR OFFICE LSE ONLY City of'Tigard NOV 19 2023 Received Date/By: : Permit#: llACJ t6tw •A'`uu {� ��/t III13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review • S Phone: 503.718.2439 Fax: 503.598.I(j�'Q4N//'� y Related Permit#: V1 I 1 'JF�ILtAIL: Date/By: Inspection Line: 503.639.4175 BUILDING A'w DIVISION JJ Ready Date/By. furls: ® See Page 2 for TIGARD, Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ®New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. 0 Demolition El Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. El 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building less to ground,or exceeds 14.000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family 0 Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived AddJob#: Job site address: 13732 SW River Terrace Blvd ❑100H ooP or moew motor load of system 100H more. ❑"A","E","t-2","1.3", City/State/ZIP: Sherwood/ OR/97140 ❑Six or more residential units. occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: RTTC ❑Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE SW Jean Louise Rd Description j Qty. ) Each I Total I New residential single-or multi-family dwelling unit. Subdivision: River Terrace Town Center Lot#:120 Includes attached garage. 1,000 sq.ft.or less 1 168.54 4 Tax map/parcel#: 2s1060003300 Ea add'l 500 sq.ft or portion 3 33.92 t DESCRIPTION OF WORK Limited energy,residential 75.00 2 NEW HOME CONSTRUCTION (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq,ft.) PROPERTY OWNER El TENANT Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation Name: THNC OREGON LLC 200 amps or less 100.70 2 Address: 15231 Laguna Canyon Rd STE 250 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Irvine CA 92618 601 amps to 1,000 amps 301,04 2 Phone:(503)310-7571 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: Fsandoval@newhomeco.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 al APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: THNC OREGON LLC above service or feeder fee, each branch circuit 7.42 2 Contact name: Frank Sandoval B.Fee for branch circuits without sAddress: 15455 NW Greenbrier Parkway#240 branch cie rcuitrfuederfee,first 56.18 2 City/State/ZIP: Beaverton OR 97006 Each add'l branch circuit 7.42 2 503 310 7571 Fax:: Miscellaneous(service or feeder not included) Phone: ( ( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: Fsandoval@newhomeco.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Development Northwest Inc., DBA Wolcott Electrical Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address:1075 W Historic Columbia River Hwy panel,alteration,or extension. 0 See Page 2 2 City/State/ZIP:Troutdale, OR, 97060 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503)853-9420 Fax:( ) Investigation(1 hr min) 90.00/hr Email:MWOLCOTT@WOLCOTT.PRO Industrial plant(Ihrmin) 78.18ihr Inspections for which no fee is 90.00/hr CCB Lie.:112220 Electrical Lie.:C 1272 Suprv.Lic.:5782S specifically listed(1/2'hr min) ELECTRICAL.PERMIT FEES: Suprv.Electrician signature,required:', Subtotal: Print name:David Campbell Date:10/12/2023 0 Plan Review Required(25%of permit fee): /� State surcharge(12%of permit fee): Authorized signature: 4 w 4 k0 TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Malachi J. Wolcott Date:10/12/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\BuitdinglPermits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(1 l/05tCOMAVEB PIumbing Permit Applicati ° '' Building Fixtures 2 ryry FOR oI1 1( 1. I SI' ()NI,v A City of Tigard N O V 9 202J Received Permit Ni'.. \ 1J 1J,l b�bt/rt IIIv 13125 SW Hall Blvd.,Tigard,OR 97223 DatcB'y: l 111 ...Phone: 5037182439 Fax 503598 an Review tS Other Permit No.' C'��'Y OF TIGNHU D Date/By: Inspection Line: 503.639.4175 } "'AGAR!) BUILDING DIVISIQi'' Date Ready ./B fiats: VI See Page 2 for ov Internet: www ti and-or. g g Notified Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE' ®New construction ❑Demolition Far special inforaration use checklist. Description j Qty. 1 Ea. ( Total ❑Addition/alteration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUcI1ON SFR(I)bath 312,70 SO I-and 2-family dwelling Commercial/industrial SFR(2)bath 1 437.78 SFR(3)bath 500.32 ❑Accessory building ❑Multi-family Each additional bath/kitchen 25.02 ❑Master builder ❑Other: Fire sprinkler( sq.11) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 13732 SW River Terrace Blvd Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18,76 City/State/ZIP: Sherwood/OR/97140 Footing drain(no.linear ft,:_) Page 2 Suite/bldg./apt.no.: I Project name: RTTC Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 SW Jean Louise Rd. Rain drain connector 18.76 Sanitary sewer(no linear ft.:_) Page 2 Storm sewer(no.linear ft.:_) Page 2 Water service(no linear ft:_) Page 2 Subdivision: River Terrace Town Center I Lot no.:120 Fixture or item: Tax map/parcel no.: 2s1060003300 Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 New Home Construction Clothes washer 25.02 Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 04 PROPERTY OWNER ' 0 TENANT Expansion tank 12.51 Name: TNHC OREGON LLC Fixture/sewercap 25.02 Floor drain/floor sink/hub 25.02 Address: 15231 Laguna Canyon Rd STE 250 Garbage disposal 25.02 City/State/ZIP: Irvine CA 92618 Hose bib 25.02 Phone:(503)310-7571 Fax:( ) Ice maker 12.51 ] A'lE'LICANT a CONTACT PERSON Interceptor/grease trap 25.02 Business name: THNC OREGON LLC Medical gas(value:$ ) Page 2 Primer 12.51 Contact name: Frank Sandoval Roof drain(commercial) 12.51 Address: 15455 NW Greenbrier Parkway #240 Sink/basin/lavatory 25.02 City/State/ZIP: Beaverton OR 97006 Solar units(potable water) 62.54 Phone:(503)310-7571 Fax::( ) Tub/shower/shower pan 12.51 E-mail: Urinal 25.02 Water closet 25.02 CONTRACTOR Water heater 37.52 Business name:Wolcott Plumbing Water piping/DWV 56.29 Address:1075 West Historic Columbia River Hwy Other: 25.02 City/State/ZIP:Troutdale OR. 97060 Subtotal Phone:( 503-667-1781 Fax:( ) Minimum permit fee: $72.50 CCB Lie.:112220 ►I Plumbing Lie.no.:26824 PB Plan review (25%of pennit fee) t State surcharge(12%of permit fee) Authorized signature: A ""'���� )01 ..........,....._ TOTAL PERMIT FEE Print name:Mark Baleme Date:10/12/2023 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. "Fee methodology set by Tri-County Building Industry Service Board. 1\Buiiding'Permits\PLML/-PernniApp.doe 10/01/09 440-4616T(10/02/COMAVEB) 0 f.C_ Se ri,liv -e_f / D • Building Division One & Two-Family Dwelling T 1 G A R© Fees Checklist PERMI T INFORMATION: Application Date - FEE VERSION ' 5 U'`( ZoZ l r Permit#: mS I Zp23 b b(.D t l Plan #: rota D Floors: 3 Valuation: Covered Porch: 57b Basement 3 Deck: q 8 1 ` Floor 13 L la Bedrooms: 11 WC (toilets) Deck Cover: 9 (a 2' Floor 7;5 3 Floor3'Lavatories Patio Cover — 37 3 1 Tub/shower 2 Accessory Struct. R-3 Total l 59 2 Laundry Tray _ Water Heater FiG7a7s--/ - ec Garage SCE, Exhaust Vents t1 Gas Flue Vents �—' Total for Elec. 2-1. b 0 Backflow Prey. _l urnace Heat Pump /620 # for Electrical BBQ �_ Gas Fireplace V �� #Fuel Lines 6 FEES: Description: Fee App 'es: Fee Entered: Prov Revw: Planning g \ _� ��� Info Proc/Arch: Lg$2.00 (over 11x17) LLD b� Qtip io, -z, 1� Info Proc/Arch: Sm $.50 (up to 11x17) I. d17 UA,,1 b► , 0JI o✓i and - Metro CET: Residential Use School CET: District: 135 V Tigard CET: Admin Tigard CET: ODHCS Tigard CET: AH ,/ Electrical Permit: Permit Fee: Limited Energy: 12% State Surcharge Mech. Permit: Permit Fee: 12% State Surcharge Plumbing Permit: Permit Fee: ,/ 12% State Surcharge Erosion Control: w/Permit - Ping I:\Building\Forms\ResPlanCheckFees_Dec2022_AA.doc 12/21/22 Page 1 City of Tigard NOV 29 20?' c �` COMMUNITY DEVELOPMENT DEPARTMENT CITY�FT#GBC m BUILDING DIVISIOI'Building Permit Review - Residential TIGARD Building Permit #: MSAIA) '006I461 Site Address: 13732 SW River Terrace Boulevard IX Verified in Accela Project Name: River Terrace Town Center- Building 3 Lot/Unit #: 120 Proposal: New Rowhouse Zone: C-C Housing Type: ❑ SFR(❑Single Detached 0 Duplex 0 Triplex 0 ADU) N Rowhouse❑Cottage Cluster 0 CYU ❑Quad 0 Other Required Site Plan Elements: E31 3 copies of site plan on max 11x17" X Drawn to standard scale 0 Retained trees, drip line/ trcc protcction ® North arrow IX Street and site trees shown / labeled IX Site address, project name, lot # .84-eble-ealculating trcc canopy at maturity Cil Street names (N/A for SFR) IX Applicant name and phone # 0 Courtyard rcctanglc dimcnsioncd (if applicable) IX Lot and setback dimensions IX Vision clearance triangle ® Existing structures &square footagc IX Utility locations &easements IX Footprint of new structure and FFE IX Property corner elevations E Sidewalk/driveway dimensioned 0 LIDA (>1,0001f di3turbancc) IIX Lot area and lot coverage percentage IX Erosion control Required Elevation Plan Elements: (For SFR: calcs needed only on street-facing) Summary table with calculations for: X Drawn to standard scale ®Total facade area IX Building height dimensioned IX Total window and door area LX Façade dimensioned IX Windows and doors dimensioned IX Garage doors dimensioned Required Floor Plan Elements: (Not required for SFR) 2 Summary table that includes ® Each story dimensioned IX Total floor area ® Each story floor area calculated IX Floor area per story Planning Review The following standards have been met: 12' 0'interior Setbacks U Front:8'Porch Rear:3'or 20'if Side: 3'alley Min/Max Street Side: 8' /20'max Garage:3 or 20'if driveway parking provided driveway parking Height EXMax. Height: 45' Proposed Height: 33' 6" provided El Yes 0 N/A Landscape,— 75%coverage across all of Building 3. Per PDR,landscape taken across all units, not per lot ❑ Yes ® N/A Screening (Quad only) ® Yes ❑ N/A % Window Coverage ---18% across all of Building 3 ® Yes ❑ N/A Garage (SFR Only) Parking (Other Res) IX Yes ❑ N/A Entrance (SFR, Rowhouse, Quad only) Facing public street ® Yes ❑ N/A Other building design standards (Rowhouse only) ❑ Yes ® N/A Accessory Structure Standards ❑ Yes ® No Qualifying pre-existing unit exempt from standards (Cottage unit only) Additional standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads: ® Yes 0 N/A Unit Count: 5 IX Yes ❑ N/A Lot Width and Sizes 15' min width I] Yes 0 N/A Pathway—Paved access connecting to sidewalk through Tract M Additional standards for Courtyard Units and Cottage Clusters only: ❑ Yes N/A Unit Area: ❑ Yes N/A Floor Area (per story) ❑ Yes N/A Courtyard O Yes N/A Fence ❑ Yes 0 No ®N/A Clean Water Services - Service Provider Letter (lot platted prior to 9/10/1995) ❑ Yes ❑ No E1N/A Public Facilities Improvement (PFI) Permit: Required: ❑ Yes ❑ No Applied For: 0 Yes ❑ No, stop intake 1 Sensitive Lands: ® Yes 0 No PDR2021-00004 ❑x Main Land Use Case #s: 0 Conditions met li Applicant notified of land(os_e a n date: Submit development plans by 1/31/25.Final Occupancy by 1/31/27 Approved By Planning: Imo"' Date: 11/21/2023 Notes has frontage on RT Bo1levar see RT Boulevard Addendum Revision 1: 0 Appfoved ❑ Not Approved Date: Revision 2: 0 Approved 0 Not Approved Date: Building Permit Submittal Original Submittal Date: `\UA ��� Site Plans #: 3 Building Plans #: 3 Building Permit #: 'Building permit # entered on page 1 Workflow Routing: f 'Planning Engineering VPermit Coordinator 17' uilding Workflow Sign-off: /Sign-off for Planning (include notes from planning review) Route Documents: Hdi Engineering: (1) copy of permit application, (1) site plan, (1) building plan a/nd original plan review routing form. vl Building: original permit application, site plans, building plans, engineer and beam calculations and trust details, if applicable, etc. Permit Technician: -42 altr\I `' VAAk. Date: IZIS I2o23 Notes: Engineering Review ❑ PFI Permit: 'Slope at building pad: ok 'Conditions met prior to issuance of permit ®'Easements (encroachments) per engineering conditions of approval and plat .'Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes P•No Assess Water Quantity Fee in-lieu: 0 Yes eT No LIDA Facility on lot: ❑ Yes 1r.Nlo Add Fee: 0 Yes 0 No Q Final Plat Recorded ❑ NOT Approved: Date: Notes: Approved By Engineering: Date: /2//77 3 Revision 1: 0 Approved Not Approved Date: Revision 2: ❑ Approved 0 Not Approved Date: Permit Coordinator Review conditions met prior to permit issuance ❑ Approved, NOT Released: Date notified applicant: ❑ ENG Revisions Required: Date notified applicant: Ca1SDC Exemption: 0 Applied for 0 Received Foes not apply gADC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A IA Tigard Trans SDC: Yes 0 N/A Deferred Parks SDC: Yes ❑ N/A El Deferred LIDA ❑ Yes yQ yr N/A _ ys to Issue/Approved by Permit Coordinator: � ` Date: 0- IS-J" 2-3 Revision 1: ❑ Approved 0 Not Approved Date: Revision 2: 0 Approved 0 Not Approved Date: City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT T1GAz River Terrace Building Permit Review Addendum Building Permit #: M$1f/A23 .001,A Site Address: 13732 SW River Terrace Boulevard Project Name: River Terrace Town Center Lot #: 120 (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review of River Terrace Plan District Design Standards (18.640.070.1): Is the project subject to the plan district design standards? E Yes ❑ No 1.Articulation: a minimum of 1 element per each street-facing facade that has 30-60 ft. of frontage.An additional element required for lots with over 60 ft. of street frontage shall be provided every 30 ft. Balcony w/ access 2 Window Projection Vertical Wall Offset a Porch min. 5 ft. deep ft. deep min. 2ft.,5 ft.wide min. 2 ft.,6ft.wide Gabled dormer ® ❑ ❑ x❑ ❑ 2. Eyes on the street: a minimum of 12%of each street facing facade must include windows or entrance doors. Percentage Shown: 18% 3. Entrances:At least one entrance must meet both of the following standards: x❑ Parallel to street,angle no more than 45° from street, EMax. 8 ft. setback from longest street- facing wall g or open onto porch Entrance opens to a porch: x❑ Yes ❑ No If yes,all the following apply: x❑ 25 sq.ft. min. x❑ One street facing entry © 12 ft.max. roof above floor of porch x❑ 5 ft. depth min. El 30%min.porch roof coverage 4. Detailed Design:All buildings shall include a min. of five of the following elements on all street-facing facades: x❑ Covered porch min. 5 ft.wide x 5 ft. deep ❑ Recessed entry area min. 5 ft.wide x 2 ft. deep E Wall offset min. 16 inches 0 Dormer min. 4 ft.wide E Roof eave min. 12 inch projection 0 Roof offset min.of 2 ft. ❑ Roof shingles either tile or wood E Gable,hip or gambrel roof design ❑ Roof pitch oriented south min. 500 sq. ft. ❑ Horizontal lap siding min. 3-7 inches wide ❑ Accent siding min. 40%of street facade E Window trim min. 2 '/2"wide by 5/8"deep ❑ Window recess min. 3 inches for all street facing ❑ Bay window min. 5 ft.wide by 2 ft. deep El Balcony min. 5 ft.wide x 3 ft. deep with inside access ❑ Attached garage is 35%or less of street facade 5. Gar d Carports:May face the front or side lot line on a corner lot. Setbacks: No closer to front or side lot line, n est street-facing wall. ❑ Yes ❑ No. If No (Check one): El May extend up to 5 ft. if there is a covered r ch and garage does not extend beyond the front porch. ❑ May extend up to 5 ft.where the garage is part of a two-sto and there is a window at the second story above the garage that faces the street with a min. area of 12 sq.ft. Width: (Check one) ❑ 12-foot-wide garage door El 40%max. of street facade ❑ 50%max. of street facade with 7 detailed design elements Notes: Garage is facing the alleyway Approved By Planning: Date: 11/21/2023 I:\Bui(ding\Forms\BI dgPermitRvw_RES_RT_121417.do