Permit CITY OF TIGARD MASTER PERMIT
: 4 .
■ . COMMUNITY DEVELOPMENT Permit#: MST2023-00466
Date Issued: 10/04/2023
T I G A R I.) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S104AB00500
Jurisdiction: Tigard
Site address: 12005 SW MORNING HILL DR
Subdivision: MORNING HILL NO.1 Lot: 11
Project: Erickson
Project Description: Rooftop solar PV system 2.8 kW and (1)circuit.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $1,960.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp:
0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 1
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
y Audio&Stereo:
N HVAC: N Securit Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Rooftop solar array 2.8 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
ERICKSON,SANDRA L ION DEVELOPER LLC Required Items and Reports(Conditions)
12005 SW MORNING HILL DR 3214 NORTH UNIVERSITY AVE
TIGARD,OR 97223 503
PROVO,UT 84604
PHONE: PHONE: 888-781-7074
FAX:
Total Fees: $377.31
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTI•, : -gon law requires yo to f.11ow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
ac9-nnl-nnln thrni -/ ••`Ltti �
-nnl-anon vv.,,. .- a nhfain a r, v of tha rulac nr rlirart ni tactinnc to fCMIMf.by Tallinn cf1B2 929 1QR7 nr 1 An 119 94dd
Issued By / " it_�/ Permittee Signature: it a9\7tIrakU)n.
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application
Residential RECEIVED FOR OFFICE USE()NE)" A
Cityof Tigard RECEIVED Received n I I� n,_�n ytyl PermitNo.: Mg1/jp'�3. OU�1bb
g Date/By: "I w J( r�Y
13125 SW Hall Blvd.,Tigard,OR 9722 [P 2 2023 Plan Review
Phone: 503.718.2439 Fax: 503.598.1A- Date/By: �� ?/� / Other Permit:
Inspection Line: 503.639.4175 Date Ready/By: `' Juns' El See Page 2 for
' i t ^I U
Internet: www tgard or.gov CITY OF TIGARD Notified/Method:(0 ,).-(a 3 ` Supplemental Information
BUILDING DIVISION EIMa'
'''TYPE OE WORK"' tr" REQUIRED DATAm'f AND 2-FAMILY DWELLING
❑New construction 0 Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement ®Other: PV Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
Valuation: $ 1,960
® 1-and 2-family dwelling ❑Commercial/industrial
Number of bedrooms:
0 Accessory building ❑Multi-family
❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 12005 SW Morning Hill Dr New dwelling area: square feet
City/State/ZIP: Tigard,Oregon 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Erickson Solar Install Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA;. OMMERCIAL-USE CHECKLIST
Subdivision: Morning Hill No 1 Lot no.: 11 Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: 2S104AB00500/R1110871 equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK ,.- work indicated on this application.
Installation of solar panels on existing residential roof. Valuation: $
2.8 kW.Addition of 1 0-30A circuit. Existing building area: square feet
New building area: square feet
"4" PROPERTY OWNER 0 TENANT Number of stories:
Name: Sandra Erickson Type of construction:
Address: 12005 SW Morning Hill Dr Occupancy groups:
City/State/ZIP: Tigard,Oregon 97223 Existing:
Phone:((360))513-2078 Fax:( ) New:
® APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES*
w'; (Please refer to fee Schedule)
Business name: ION Developer LLC Structural plan review fee(or deposit):
Contact name: Dustin Davidson
FLS plan review fee(if applicable):
Address:4801 N University Ave#900
Total fees due upon application:
City/State/ZIP: Provo, UT 84604
Amount received:
Phone:( 888) 781-7074 Fax: :( ) .
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* ,
E-mail: permits@IOnSOIar.COm '
,.., Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name: ION Developer LLC Submit two(2)sets of roof plan with connection details
p and fire department access,along with the 2010 Oregon
Address: 4801 N University Ave#900 Solar Installation Specialty Code checklist.
City/State/ZIP: Permit Fee(includes plan review $180.00
Y Provo, UT 84604 and administrative fees):
Phone:( 888) 781-7074 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.: 230394 Total fee due upon application: $201.60
Authorized signature: ' ) This permit application expires if a permit is not obtained
s� within 180 days after it has been accepted as complete.
*Fee methodology set by Tri-County Building Industry
Print name: Dustin Davidson Date: 09-11-2023 Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB)
Document Ref:B4HA2-YQQOU-M49HQ-ZQEVK Page 1 of 7
QECEIVEDElectrical Permit Applicati FOR OFFICE USE oNLv
City of Tigard Received
Date/B : Permit#: kA \ '1 11 .p�qb,
13125 SW Hall Blvd.,Tigard,OR 97223 SEP 1 2 2023 Plan Review
I Phone: 503.718.2439 Fax: 503.598.1960 Date/B : Related Permit#:
Inspection Line: 503.639.4175 CITY OF TIGARD Ready Date/By: Juris: ® See Page 2 for
I I(,A R ll Internet: www.tigard-or.gov Notified Method: Supplemental Information
BUILDING DIVISION
'.. TYPE.:OF WORK PLAN REVIEW
❑New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
O Service or feeder 400 amps or more 0 Building over three stories.
❑Demolition ®Other: PV Solar where the available fault current ❑Marinas and boatyards.
v,
,CATEGORY OF'CONSTRU 'ION..;, exceeds 10,000 amps at 150 volts or ❑Floating buildings.
® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑Multi-family 0 Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or
OB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address: 12005 SW Morning Hill Dr IO0HP or more. ❑"A","E",°1-z",°'1-3",
City/State/ZIP: Tigard, Oregon 97223 El Six or more residential units. occupancy.
ty g g ❑Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name: Erickson Solar Install 0 Hazardous locations. ❑Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: `','. FEE SCHEDULE
Description I Qty. I Each I Total I
New residential single-or multi-family dwelling unit.
Subdivision: Morning Hill No 1 Lot#: 11 Includes attached garage.
Tax map/parcel#: 1,000 sq.ft.or less 168.54 4
2S104AB00500/R1110871 Ea.add'l 500 sq.ft.or portion 33.92 1
,. DESCRIPTION OF WORK Limited energy,residential
Installation of solar panels on existing residential roof.
(with above sq.ft.) 75.00 2
Limited energy,multi-family 75.00 2
2.8 kW.Addition of 1 0-30A circuit. residential(with above sq.ft.)
Renewable Energy ❑ See Page 2
: ® PROPERTY OWNER ❑ TENANT ., Services or feeders installation,alteration,and/or relocation
Name: Sandra Erickson 200 amps or less 100.70 2
201 amps to 400 amps 133.56 2
Address: 12005 SW Morning Hill Dr 401 amps to 600 amps 200.34 2
City/State/ZIP: Tigard,Oregon 97223 601 amps to 1,000 amps 301.04 2
Phone:((360))513-2078 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: sandye73@icloud.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
Branch circuits—new alteration or extension,per panel
®.'APPLICANT ',:::,1: C01TTAC PERSON s
� A.Fee for branch circuits with
Business name: ION Developer LLC above service or feeder fee, 7.42 2
each branch circuit
Contact name: Dustin Davidson B.Fee for branch circuits without
Address: service or feeder fee,first 1 56.18 56.18 2
4801 N University Ave#900 branch circuit
Each add'l branch circuit 7.42 2
City/State/ZIP: Provo, UT 84604 Miscellaneous(service or feeder not included)
Phone:(888) 781-7074 Fax: :( ) Each manufactured or modular 67.84 2
Email: dwelling,service and/or feeder
permits@ionsolar.com Reconnect only 67.84 2
s...,,.,_._ .. a. .«. CONTRACTOR.:, _ _w k_,. s ... ." -'• Pump or irrigation circle 67.84 2
Business name: ION Developer LLC Sign or outline lighting 67.84 2
Address: 4801 N UniversityAve#900 Signalnel, Meru iont(s)or extension.eionergy 0 See Page 2 2
panel,alteration,or
City/State/ZIP: Provo, UT 84604 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:(888) 781-7074 Fax:( ) Investigation(1 hr min) 90.00/hr
Email: Industrial plant(1 hr min) 78.18/hr
permits@ionsolar.com Inspections for which no fee is
specificall listed 'A hr mm 90.00/hr
CCB Lic.: 230394 Electrical Lic.: C1524 Suprv.Lic.: 6098S y )
(} ELECT2ICAL.1'ERMIT FEES
Suprv.Electrician signature,required: &lj`+ rf Subtotal: 156.88
Print name: David S Conrad Date: 09-11-2023 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee): 18.82
Authorized signature: 2tt04,1,0,e,.. TOTAL PERMIT FEE: 175.70
This permit application expires if a permit is not obtained within 180
Print name: Dustin Davidson Date: 09-11-2023 days after it has been accepted as complete.
* Number of inspections allowed per permit.
C\Building\Pernvts\ELC PenuitApp_ELR_ERE.doc Rev 06/172015 440-4615T(11/05/COM/WEB
Document Ref:B4HA2-YQQOU-M49HQ-ZQEVK Page 2 of 7
i .
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
DULE ,ry
DescrFee for all residential systems combined: $75.00 Renewable
1 Qty. I Each Total
I1
3' Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 1 100.70 100.70 2
5.01 to 15 kva 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener*
>100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
El Vacuum Systems* >100 kva-no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specificall listed(Yz hr min)
Fee for each commercial system: $75.00 allowed
Subtotal(Enter on Page 1): 100.70
y * Number of inspections allowe per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:\Building\Pertuits\ELC_PermitApp_ELR ERE doe Rev 06/17/2015
Document Ref:B4HA2-YQQOUi r+t49HQ-ZQEVK Page 3 of 7
RECEIVED
City of Tigard SEP 1 2 2023
• '� Building Division CITY OF TiGARD
13125 SW Hall Blvd,Tigard,OR 97223 BUILDING DIVISION
Phone: 503.718.2439 Fax: 503.598.1960
T I GARD Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12005 SW Morning Hill Dr
City: Tigard Zip: 97223
Owner's Name: Sandra Erickson Date: 09-11-2023
Contractor's Name: ION Developer LLC CCB #: 230394
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Located in a flood prescriptive path, follow
Area plain/flood way? 0 No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure Yes If"Yes", qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes",qualifies for
family townhomes x❑ Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structuresIf"Yes", qualifies for
other than
❑ Yes the prescriptive path.
above
❑ No
1
I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
Document Ref:B4HA2-YQQ0U-M49HQ-ZQEVK Page 4 of 7
Is the construction
material wood and does 0 Yes
Type of If"Yes",
Yes , qualifies for
Construction the construction qualify p p p
as "conventional light ❑ N0 the rescri tive ath.
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. (1 Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
If"Yes", qualifies for
Nominal lumber. j Yes the prescriptive path.
❑ No
Is the combined weight E Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance n Yes
with Section 305.4(3)of If Yes , qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of n of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑x of composition
shingle.
Is the roof mounted X❑ Yes
Connections of solar assembly
the solar assembly connected to roof No If"Yes", qualifies for
framingblockin ❑ the prescriptive path.
to the roof or g
directly?
2
I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
Document Ref:B4HA2 DOU-M49H0 Page 5 of 7
•
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less?
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels If the width of the panel
P Width of roofing is less than 18 inches,
panels? 18 inches or less
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/2"thickness, n Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof n Yes the prescriptive path.
surface. 7 No
3
I:/Building/Forms/PhotoV oltaic-Checklist02-01-11.docx
Docuinent3Ref:B4HA2 X QU-M49HQ ZQEVI( Page 6 of 7
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAB
Model Number: SIL-400 HC+
Listing Agency:
4
I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
r D6 11ment Re'f,841'1 'YQQQ,1 14$HQ-ZQEVK.. Page 7 of 7
N , •
••v;•N.��;i••••ii•k�ii•��;;;1�X. ; i i❖; ;;•i•ii•���iii1;;ii;i;•��Ki•;i1 •�;�i;�•;fi/lt.�rK�r�.•;.•Ii�••i�•;�;�.1'1•••
!.1#•��:i::!•i t•i.•t•t•!:��:!:::!.t.!.•.i:❖:t�i t::t t•t•Nt��t t ti!t t i it.t",,t t i�t••tom"t.t•Nt••t•Nt4,.��i."t•�4�..Nt Nt itt"t���t4•....%tt t ft�1•e•.,
..•4; !�•i•,
el.`• Signature Certificate !.'.:
: Reference number:B4HA2-YQQOU-M49HQ-ZQEVK ••••.'
MI, ;••♦••:
:: `❖•
..••••• Signer Timestamp Signature ,•.♦.•.
pp; _ ___...
Dustin Davidson :;
;:.; Email:dustin.davidson@ionsolar.com ':.:•:.
••♦••• scs -P� I '00'•
••• Sent: 11 Sep 2023 19:17:57 UTC i•
%i.;
:e:4•, Signed: 11 Sep 2023 19:17:58 UTC ��:
+:' IP address:136.41.65.14 •♦:•;•
.".
'44.
.•ii�, �...••
..-•-: Document completed by all parties on: A•�•�
y:,:, 11 Sep 2023 19:17:58 UTC ::::
❖} •Page 1 of 1 •;•;••,
J.•i
••• •�•••,
•
,A 'W.'
••. ••••4
Vie, .•,
.4. •
••j♦j
••♦•i
•••••• i•••♦••♦♦/ •••'
♦•• •.•
•••••' i•♦•i
•••
••11••, .�.�%_.
VOebe
•.•
•••;• ,❖••�
♦•.' !•♦:,
•.• !.♦,,
,.,.•., ...O..
•., ••••,
�•,.•• 1••••;
�••••. !•..•,
•.❖..
�•: Signed with PandaDoc ;:;:;;
••♦• •.
•'� : PandaDoc is a document workflow and certified eSignature �,:.. T; �•;
❖•• solution trusted by 40,000+companies worldwide. ❑i 'a—
•.. •,4%
AN
•♦••'iiii ii ii iiii iiii'i iii ii i i•�•i ii i iii i iii ii ii i ii s i 4i iiiiii iii i i ii i i i i iii i ii i�••�••
!.•►♦......•...i♦.1./ ......1••..•..i♦.i..i.i♦i....i.ii..i.i♦..i..♦....i.....i..i...i..."..iii.�.
D••!•b�.!���hMJ�.O�:�i�:•�•!��iL.+��•�•i�i•�•�••L!d�••��i•��O�:ii i�i��M•���ii�.4��.!�:••:�:•�����LO•O a i:ii:�b