Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (19)
CITY OF TIGARD MASTER PERMIT II ' COMMUNITY DEVELOPMENT Permit#: MST2023-00639 T I I_;A R I) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/22/2024 Parcel: 2S110BA05700 Jurisdiction: Tigard Site address: 11885 SW WILDWOOD ST Subdivision: SHADOW HILLS Lot: 8 Project: Carlson Project Description: Rooftop solar PV system 11.07 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $33,580.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 LaundryTrays: 0 Y Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Rooftop solar array 11.07 kW N Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: CARLSON FAMILY TRUST PREMIER SOLAR NW Required Items and Reports(Conditions) BY CARLSON,DARIN LEE& 5690 SW 88TH AVE CARLSON,JENNIFER MARIE TRS PORTLAND,OR 97225 11885 SW WILDWOOD ST TIGARD,OR 97224 PHONE: PHONE: 503-828-9500 FAX: Total Fees: $354.83 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTIO • •regon law requ' you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9_(1111-M11n thrnnnh • < 9_nnLnna 1 ANEZELerr- a rnnw of the nilac nr rlirart ni iactinnc to fll IN(:by Tallinn 6111 919 1 O 7 nr I nn 119 92dd Issued By: fi�7— Permittee Signature: et V1 1ir pP w. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 0 lex...41,-...4 /;v40, ie,ye..._ If ItyikliEgisymit _Ap !911. RECEIVED I ON Of I 11 I I 1 0\1 1 City of Tigard Date3y:It \ 1 1,4•fip i' PanitN°--VAitbri/S.00 ro Sci 13125 SWHall Blvd,Tigard,OR 9722A, 2 Plan Revie11 w i 5 i. A.A- i Phone: 503.718.2439 Fax: 503.598. 0 110f Date/By Other Penn& 1 11(.\ii) Inspection Line: 503.639_4175 Z023 Date Ready/By: , . A i ,,,,i, 0 See Page 4 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: I 4 I 1,46,..1.rit, i It Supplemental Information BUILDING DIVISION E rna.i.Le-6-fkke.,c,rL,• , TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ill New construction L2 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all A Addition/alteration/replacement El Other: equipment,materials,labor,overhead,and the profit for the work indicated on this application. CATEGORY OF CONSTRUCTION Valuation:A ,1-and 2-family dwelling D Commercial/industrial $ $33580.00 _ ElAccessory building 0 Multi-family Number of bedrooms: it Master builder E Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: lob site address: 11885 SW IMIdwood St. New dwelling area: square feet City/Stste/Z1P: Tigard, OR 97224 Garage/carport area: square feet Suite/bIdgJapt.no.: Project name: Carlson Covered porch area: square feet Cross street/directions to job site: Deck area: square feet SW WIdwood St&SW McFarland Blvd Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST 1 Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK I, work indicated on this application. 11.07 kW Rooftop PV System —4 Valuation: $ Existing building area: square feet New building area: square feet ' 4 PROPERTY OWNER 0 TENANT Number of stories: Name: Jenny Carlson Type of construction: Address: 11885 SW iNildwood St OeenPaneY Ernuns: City/State/ZIP: Tigard, OR 97224 Existing: Phone:( )(503)382-9007 Fax:( ) New: MI APPLICANT gg CONTACT' PERSON BUILDING PERMIT FEES* (Muse refer to fee schedule) ' Business name: Premier Solar NW Structural plan review fee(or deposit): Contact name: Alan Porter FLS plan review fee(if applicable): Address: 5690 SW 88th Ave Total fees due upon application: City/State/ZIP: Portland OR 97225 Phone:(503)828-9500 Fax::( ) Amount received: PHOTOVOLTAIC SOLAR PANEL SYStEM FEES* swan aporter( premiersolamw.com 7 Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name: Premier Solar NW Submit two(2)sets of roof plan with connection details i - and fire department access,along with the 2010 Oregon I Address: 5690 SW 88th Ave Solar Installation Specialty Code checklist. CirY/SrareraP: Portland OR 97225 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)828-9500 Fax:( ) State surcharge(12%of permit fee): $21.60 , CCB lie.: 241524 Total fee due upon application: $201.60 _ INEMINIMMIB SARI Catimam, This permit application expires if a pertnit is not obtained within 180 days after it has been accepted as complete. i Print name: Bret Cullivan Date:12/18/23 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COMJWEB) Electrical Permit Application r 77 7:1VE I I OR 01 II( I l •I 0 NI 1 City 0/Tigard Received . Peanut#: tolubt.66c4; 01 , I _. 13125 SW Hall Blvd.,Tigard,OR 97223 - . Revi Phone: 5033182439 Fax: 503.598 l-0.1960-' ,I Plan Date/By:, Related Permit#: Inspection Line: 503.639.4175 Ready Date/By: juts: 0 See Page 2 for Internet www.tigard-or.gov (...4 i i (JF liGARD Notified/Method. Supplemental Information TYPE OF WaUltlING-DIVISIONT-------- -------------FLATN—IRYIEW--------------- 0 New construction gg Addition/alteration/replacement Please check all that apply(submit 2.sets of plans wiltems checked): 0 0 Service or feeder 400 amps or more 0 Building over three stories.Demolitkm 0 Other: o where the available fault current 0 Manna' s and boatyards. ........ CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. IN 1-and 2-family dwelling 0 CommerciaVmdustrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all odter installations. buildings. 0 Multi-family Q Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE N'FORMATION AND LOCATION 0 Emergency system. larger separately derived 0 Addition of new motor load of system. Job#: Job site address: 11885 SW Wildwood St. 10011P or more. 0 Six or more residential units. occupancy. City/State/ZIP. Tigard, OR 97224 OH are facilities. 0 Recreational vehicle parks. Suite/bldg./apt#: Project name: Carlson 0 Hazardous locations. 0 SuPPly voltage for more than 0 Service or feeder 600 amps or.more. $E0 volts nominal. Cross street/directions to job site: FEE SCHEDULE SW VVIdwood St&SW McFarland Blvd ..174.0740iiia .,.1 qty. . Each I. Total ..1. New residential single-or multi-family dwelling unit Subdivision: I Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: l/ ti4 500 sq.ft.or portion : 33.92 1 DESCRIPTION OF WORK . Limited energy,residential 75.00 2 11.07 kW Rooftop PV System (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy 0 See Page 2 i29 PROPERTY OWNER 1 0 TENANT Services or feeders installation,alteration,and/or relocation Name: Jenny Carlson 200 amps or less 100.70 2 _._..,,___ :. , ,,........_ .... _.... .. _.,....... Address: 11885 SWIAAldwood St. 201 amps to 400 amps 133.56 2 . _ . ..... _ ,, 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard, OR 97224 601 amps to 1,000 amps 301.04 2 Phone:( )(503) 382-9007 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: jenny.carlson21©gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps , 168.54 2 Branch circuits-new,alteration,or extension,per panel 1 A.Fee for branch circuits with Business name: Premier Solar NW above service or feeder fee, 7.42 2 each branch circuit Contact name: Alan Porter B.Fee for branch circuits without service or feeder fee,first Address: 5690 SW 88th Ave branch circuit 56.18 2 City/State/ZIP: Portland OR 97225 Each add'l branch circuit 7.42 2 Afiscellaneous(service or feeder not included) Phone:(503/828-9500 Fax::( .) Each manufactured or modular 67.84 2 _dwelling,service and/or feeder Email: aporter@premiersolamw.corn Reconnect only . 67.84 - 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: Premier Solar NW Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 5690 SW 88th Ave panel,alteration,or extension. 0 See Page 2 2 Ciy/State/ 1P,.. p. ola_nd 9725 Each additional inspection over allowable in any of the aboveZ rtO ..._. _ . ,.... ...., . ., . . .._ . . .. ._ _. .. Additional inspection(1 hr min) 6625/hr Phone:( 503 828-9500 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr Iran) 78.18/hr Email: aporter©premiersolamw.com Inspections for which no fee is CCB Lie.:241524 1 Electrical Lie.:ci 796 I Suprv.Lie.: 6533S specifically listed(14 hr rnin) / 90.00/lir ELECTRICAL PERMIT FEES .. 6 7,1 „i Suprv.Electrician signature,required: _1 r-4 Subtotal: 133.56 . _ .... , _ ,. .. ,.. , .._. Print name: Tim Oliver I Date: 12/18/23 o Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: Stet Cut/Lamm, TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Bret Cullivan Date: 12/18/23 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\BuildiagO.PennasIELC PamitApp ELR FRF doe Rev 06/17/2015 440-4615TO I/05/COIWWEB Electrical Permit Application-City of Tigard Page 2-Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE ion Fee for all residential systems combined: $75.00 Rene Renew a E"` T°''` I able electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.562 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is specifically listed(%,hr min) 90.00/hr COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ A• udio and Stereo Systems ❑ Boiler Controls ❑ C• lock Systems ❑ Data Telecommunication Installation ❑ F• ire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems O Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ O• utdoor Landscape Lighting* ❑ P• rotective Signaling ❑ O• ther: Total number of commercial systems: _ *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermitApp ELR_ERE.doc Rev 06/17/2015 Allyson Armstrong From: Alan Porter <aporter@premiersolarnw.com> Sent: Tuesday, January 2, 2024 3:05 PM To: Allyson Armstrong Subject: RE: Plan Check - 11885 SW Wildwood St./ MST2023-00639 You don't often get email from aporter@premiersolarnw.com. Learn why this is important We will not be over any unsupported overhangs. From:Allyson Armstrong<AllysonA@tigard-or.gov> Sent:Tuesday,January 2, 2024 2:31 PM To:Alan Porter<aporter@premiersolarnw.com> Subject: Plan Check- 11885 SW Wildwood St./MST2023-00639 Alan, In reviewing the plan submitted for 11885 SW Wildwood St. I need a little further clarification. I am unclear if the roof has overhangs. Overhangs are typically not structurally supported. Can you provide clarification as to if the structure has or does not have overhangs? I have attached the Photovoltaic Pathways document for reference. Thank you, Allyson Allyson Armstrong ' City Of Tigard t tirl tit• 1 C'3i 71a-2612Work 71E.-al3"r.lobile AilysonA.-tigard-or.g,3v 13125 SW Hall Boulevard Tigard,Oregon 97223 DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. if requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule." 1 12/28/2023 Mail-Anna Pina-Outlook Re: Incomplete Submittal For 11885 SW Wildwood St Anna Pina <anna.pina@tigard-or.gov> Thu 12/28/2023 11:56 AM To:Alan Porter <aporter@premiersolarnw.com> Thanks Alan, it will be added to the total permit fee. We will reach out when the permit has been made ready to issue with the total. Have a nice day and a Happy New Year! Anna Pina,She/Her City of Tigard Bilingual Permit Tech.Asst. l Hablo Espanol Email:anna.pina@tigard-or.gov 13125 SW Hall Boulevard Tigard,OR 97223 I� �INCLUS SIEve 1 'r WELCOMING TRc,ntctx SAFE SPACE FIN1 EVERYONE From:Alan Porter<aporter@premiersolarnw.com> Sent:Thursday, December 28, 2023 11:49 AM To:Anna Pina <anna.pina@tigard-or.gov> Subject: RE: Incomplete Submittal For 11885 SW Wildwood St You don't often get email from aporter@premiersolarnw.com. Learn why this is important Please go ahead and make copies. Will the cost just be added to the permit fees or will this be a separate charge? If it's separate then please let me know how you would like me to pay. From: Anna Pina <anna.pina@tigard-or.gov> Sent:Thursday, December 28, 2023 11:43 AM To:Alan Porter<aporter@premiersolarnw.com> Subject: Incomplete Submittal For 11885 SW Wildwood St Good morning Alan, The Building Division is in receipt of your permit application for the proposed solar project at 11885 SW Wildwood St. The plan set was received incomplete as only (1) set of calculations were received, (2) sets are required for plan review. I can make copies but will have to charge $0.25 per page. Please let me know if you would like to drop off a second set of calculations or if we can make copies and charge you for them. The permit will be created and routed for plan review once I have a complete set. Please let us know how you would like to proceed. Thank you, Anna Pina, She/Her City of Tigard Bilingual Permit Tech.Asst. l Hablo Espanol Email: anna.pina@tigard-or.gov 13125 SW Hall Boulevard Tigard,OR 97223 https://outlook.office365.com/mail/inbox/id/AAQkAGJmYmRjNjJhLWNIOWMtNGFIOS1 hNDhiLTg1 MGI5ZjZmOTdmNAAQANg4k%a2F2sNLhGpaUYk3j... 1/2 12/28/2023 Mail-Anna Pina-Outlook I Fat VELUs DIVERSE • OMU4G tc.a �sSAFE SPACE FOR EVERYONE DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E- mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule." https://outlook.office365.com/mail/inbox/id/AAQkAGJmYmRjNjJhLWNIOWMtNGFHOS1 hNDhiLTg1 MG15ZjZmOTdmNAAQANg4k%2F2sNLhGpaUYk3j... 2/2 City Tigard RECEIVED Building Division DEC ',"1 13125 SW Hall Blvd,Tigard,OR 97223 C ( ' Phone:503.718.2439 Fax:503.598.1960 BUI1DRN T l G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 11885 SW Wildwood St. City: Tigard Zip: 97224 Owner's Name: Jenny Carlson Date: 12/18/2023 Contractor's Name: Premier Solar NW CCB #: 241524 Design Parameters of the Property/Structure If"Yes", does not Is the installation Yes qualify for the Flood Hazard Located in a flood prescriptive path, follow Area plain/flood way? 0 No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes",qualifies for "C"or less? [] No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes",qualifies for family townhomes El Yes the prescriptive path. and/or their accessory Ground structures. I J No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above No 1 IiBuildingiFonns/PhotaVohic-Checklist02-01-1 I.docx Is the construction material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction as"conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight x❑ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance 0 Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar 0 No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of 0 of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. x❑ of composition shingle. Is the roof mounted 0 Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the gauge 26 or less? El Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/."thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Ni Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PhotoVoltaic-Checklist02-0I-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines,and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Silfab Model Number: SIL410BG Listing Agency: UL 4 I;Building/Forms/PhotoVoltaic-Checklist02-01-11,docx