Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (5)
la CITY OF TIGARD114 MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2023-00468 Date Issued: 10/05/2023 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S134DC04400 Jurisdiction: Tigard Site address: 11725 SW 113TH PL Subdivision: MUTTLEY'S ADDITION Lot: 5 Project: Curnes Project Description: Rooftop solar system 9.72 kW, (1)200 amp feeder and(2)branch circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $5,731.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 0 Catch Basins: 0 Bckflw Prevntr: Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc!Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 2 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: SHELDON,BRETT EARL LEE TML INTERNATIONAL LLC Required Items and Reports(Conditions) CURNES,MELINDA L 6405 E MILL PLAIN BLVD 11725 SW 113TH VANCOUVER,WA 98661 TIGARD,OR 97223 PHONE PHONE: 800-364-0470 FAX: Total Fees: $480.59 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Qc9_nn1-nnl n+hrni nLIP 0c7-nn1 nn0 � nh+oin n rnn,i of the riihme nr riirurf n,ioc+lnnc 1n nI Intl by rolfinn cr1Z 939 1 OR7 nr 1 Ann 339 94aA Issued By: / j. Permittee Signature: Fr" 1 r c` " `'z 11 Call 4639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. ' Buildin2 Permit Application Residential RECEIVE Receives FOR�OFFFICE USE ONLY ,.�� / �j City of Tigard Date/By: ei [7 , ay7 J` v10.5� "001 G8 'I 13125 SW Hall Blvd.,Tigard,OR 9722 p Plan Review Q� `/ ' = Phone: 503.718.2439 Fax: 503.598.1 � 2023 Date/By. (3 �/� Other Permit: t t- !t D Inspection Line: 503.639.4175 Date Ready/By: ` �122 c s H See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method.(0 oT 3 ki . I Supplemental Information BUILDING DIVISION L TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other:Solar equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $5731.00 ❑■ 1-and 2-family dwelling ElCommercial/industrial ❑Accessory building El Multi-familyNumber of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:11725 Sw 113th PI New dwelling area: square feet City/State/ZIP:Tigard OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solarinstall-MCurnes Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of 24 solar panels in 3 arrays on a roof-mounted 9.720kW PV System Valuation: $ Existing building area: square feet New building area: square feet © PROPERTY OWNER 0 TENANT Number of stories: Name:Melinda Curnes Type of construction: Address:11725 Sw 113th PI Occupancy groups: City/State/ZIP:Tigard OR 97223 Existing: Phone:( )503-545-6457 Fax:( ) New: NI APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:TML International LLC Structural plan review fee(or deposit): Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable): Address:6405 E Mill Plain Blvd Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Amount received: Phone:( )(360)326-0650 Fax: :( ) E-mail:permit@infinityd2d.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:TML International LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist. _ City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )(800)818-0598 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:223690 Total fee due upon application: $201.60 Authorized signature: 77�� � � �. / This permit application expires if a permit is not obtained f/LiZ4491.d22^'c-otzie2G within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:Mary Dinsmore mith Date:9/7/2023 Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE LSE OyLv City ofTigard Received ` EMBIZII 111 I 13125 SW Hall Blvd.,Tigard,OR9CEIVED Date B Phone: 503.718.2439 Fax: 503.598.1960 Plan Review q� Read Date/B Permit Related #: Inspection Line: 503.639.4175 SEP 1 2 20La y: 0 See Page 2 for T I G A I"1-1 Internet: Date/By: Suns Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF wt OF'FIG"' PLAN REVIEW ❑New construction 0 Addltlori/alYea /DiNGrEAVISIO ' Please check all that apply(submit 2 sets of plans w/items checked): ElService or feeder 400 amps or more 0 Building over three stories. El Demolition 0 Other:Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION '.: exceeds 10,000 amps at 150 volts or 0 Floating buildings. ❑■ 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural Elamps for all other installations. buildings. Multi-family ❑Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived Job#: Job site address: 11725 Sw 113th PI El Addition of new motor load of system. 100HP or more. ❑"A","E","1-2","1-3", City/State/ZIP:Tigard OR 97223 0 Six or more residential units. occupancy. 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name:Solarinstall-MCurnes 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 I DESCRIPTION OF WORK Limited energy,residential Installation of 24 solar panels in 3 arrays on a roof-mounted 9.720kW PV System (with above sq.ft) 75.00 2 Limited energy,multi-family New 200 amp meter can,200 amp main service panel w 200 amp main breaker,new service feeders w 4/0 Al conductors residential(with above sq.ft.) 75.00 2 ® PROPERTY OWNER 0 TENANT Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation Name:Melinda Curnes 200 amps or less 1 100.70 2 Address:11725 Sw 113th PI 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard OR 97223 601 amps to 1,000 amps 301.04 2 Phone:( )503-545-6457 Fax:( ) Over 1,000 amps or volts 552.26 2 Email:sheldon8510@comcast.net Temporary services or feeders installation,alteration,and/or relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature:Authorized VIA Contract Date: 401 amps to 599 amps 168.54 2 APPLICANT ® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:TML International LLC above service or feeder fee, each branch circuit 1 7.42 2 Contact name:Mary Dinsmore-Smith B.Fee for branch circuits without Address:6405 E Mill Plain Blvd service or feeder fee,first branch circuit 56.18 2 City/State/ZIP:Vancouver, WA 98661 Each add'!branch circuit 1 7.42 2 Phone: Miscellaneous(service or feeder not included) ( )(360)326-0650 Fax: :( ) Each manufactured or modular dwellin service and/or feeder 67.84 2 Email:permit@infinityd2d.com g' Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:TML International LLC Sign or outline lighting 67.84 2 Address:6405 E Mill Plain Blvd Signal circuit(s)or limited-energy panel,alteration,or extension. ❑ See Page 2 2 Each additional inspection over allowable in any of the above City/State/ZIP:Vancouver,WA 98661 Additional inspection(1 hr min) 66.25/hr Phone:( )(800)818-0598 Fax:( ) Investigation(1 hr min) 90.00/hr Email:permit@infinityd2d.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lie.:223690 Electrical Lic.:C1556 Suprv.Lie.:6210S specifically listed(1/4 hr min) 90.00/hr Suprv.Electrician signature,required:3-cortt2_.e27uc ELECTRICAL PERMIT FEES Subtotal: Print name:Scott LeDuc Date:9/7/2023 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: ,fle,6f1'1 �LIZdd'IL622��f� TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Mary Dinsmore- ith Date:9/7/2023 days after it has been accepted as complete. ' Number of inspections allowed per permit. 1:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(l1/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description I Qty. I Each I Total I * Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 100.70 2 Check Type of Work Involved: 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Each additional inspection is 66.25/hr 1 Other: charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(%hr min) ELECTRICAL PERMIT FEES COMMERCIAL WORK ONLY: Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: — *No licenses are required. Licenses are required for all other installations 1\Building\Permits\ELC PermitApp_ELR_ERE.doc Rev 06/17/2015 City of Tigard " Building Division RECEIVED` 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 SEP i 2 102 3 TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov CITY OF TIGARD BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 11725 Sw 113th PI City: Tigard Zip: 97223 Owner's Name:Melinda Curnes Date: 9/7/2023 Contractor's Name:TML International LLC CCB #: 223690 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation El Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ❑■ No OSSC or ORSC for design requirements. • Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑I Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ❑ Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction material wood and does ❑� Yes Type of If"Yes", qualifies for the construction qualify Construction No the prescriptive path. as"conventional light ❑ frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ElYes If"Yes", qualifies for the prescriptive path. ❑■ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑■ Yes the prescriptive path. ❑ No Is the combined weight ❑� Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑■ Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of n of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ▪ of composition shingle. Is the roof mounted ❑■ Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 1`/Building/Forms/PhotoVoltaic-Checklist02-01-1 l.docx _r ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? El Yes the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ❑■ Yes the prescriptive path. surface. ❑ No 3 I:/Building/Forms/PhotoVoltaic-Checkl ist02-0 1-1 1.docx R Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:Z N S H I N E Model Number:ZXM7-SH 108-405M Listing Agency: UL 61730 4 4 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx