Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
RECEIVED Aub ,,, 4, y..023 CONTRACTOR INFORMATION NEW PHOTOVOLTAIC SYSTEM 4.920kW DC/3.900kW AC Approved plans 11078 SOUTHWEST 130TH AVENUE,TIGARD,OR 97223 shall be on job site. CITY OF TIGARD BUILDING DIVISION AHJ SCOPE OF WORK VICINITY MAP (N)4.920kW DC/3.900kW AC ROOF MOUNT PV SYSTEM % SUNPATH SERVICES LLC OR-CITY OF TIGARD (12)REC SOLAR REC410AA PURE(410W)MODULES 1, ADDRESS:9978 SOUTHWEST ARCTIC (12)ENPHASE IQ8M-72-2-US(240V)MICROINVERTERS DRIVE,SS:9978 SOUTHWEST H EST5 UTILITY (1)ENPHASE IQ COMBINER 4 ,,i PHONE NUMBER:(503)313-7253 PORTLAND GENERAL ELECTRIC CO s LICENSE NUMBER:OREGON CCB I � p�A • 235715 CODES AND STANDARDS VALIDITY I�/ OF PERMIT CUSTOMER INFORMATION OREGON ELECTRICAL SPECIALTY CODE:OESC 2021 THE ISSUANCE OF A PERMIT NAME:EVELYN GRAY OREGON FIRE CODE:OFC 2021 BASED ON CONSTRUCTION OREGON STRUCTURAL SPECIALTY CODE:OSSC 2022 } ADDRESS:11078 SOUTHWEST 130TH OREGON RESIDENTIAL SPECIALTY CODE:ORSC 2021 DOCUMENTS AND OTHER a AVENUE,TIGARD,OR 97223 WIND SPEED:105 MPH DATA SHALL NOT PREVENT SNOW LOAD:25 PSF THE CODE OFFICIAL FROM COORDINATES: 45.439956, 122.810240 REQUIRING THE CORRECTION APN:R2022191 OF ERRORS. ORSC 105.4 4.920kW DC / 3.900kW AC ROOF MOUNT PV SYSTEM ill GENERAL NOTES SHEET CATALOG 1.MODULES ARE LISTED UNDER UL 1703/UL 61730 AND 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES CONFORM TO THE STANDARDS. TRANSITION FROM ARRAY WIRING TO CONDUIT PV-1 COVER SHEET 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM WIRING. TO THE STANDARDS. 11.RACKING SYSTEM SHALL BE LISTED TO UL 2703. PV-2 SITE PLAN 3.DRAWINGS ARE DIAGRAMMATIC,INDICATING GENERAL 12.FIRE RATING OF EXISTING ROOF ASSEMBLY SHALL PV-3 MOUNTING DETAILS ARRANGEMENT OF THE PV SYSTEM.ACTUAL SITE BE MAINTAINED WITH ADDITIONAL OF PHOTOVOLTAIC PV-3.1 STRUCTURAL DETAILS CONDITIONS MAY VARY. SYSTEM. 4.WORKING CLEARANCES AROUND THE NEW PV PV-4 SINGLE LINE DIAGRAM ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN PV 4.1 VOLTAGE DROP CALCULATIONS ACCORDANCEON WITH NEC 110.26.N OFFICE COPY 5.ALL GROUND WIRING CONNECTED TO THE MAIN OFFICE j r PV-4.2 ELECTRICAL CALCULATIONS SERVICE GROUNDING IN MAIN SERVICE PANEL/SERVICE PV-5 PLACARDS EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V,90°C STANDARD SS SPEC SHEETS COPPER UNLESS OTHERWISE NOTED. CITY TIC 4 T1a1�1 7.WHEN REQUIRED,A LADDER SHALL BE IN PLACE FOR L 1 OFA ARD "D INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. PROJECT ID AUR-83827 B.THE SYSTEM WILL NOT BE INTERCONNECTED BYTHE REVIEWED FORCODE COMPLIANCE CONTRACTOR UNTIL APPROVAL FROM UTILITY IS DATE 8/19/2023 RECEIVED. Annrovcd: [ I 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS CREATED BY SB THAT DO NOT REQUIRE THE PLACEMENT OF GROUND 0 .'C; LADDERS OVER OPENINGS SUCH AS WINDOWS OR SIGNATURE DOORS,CONSTRUCTION WHERE THE ACCESS POINTD LOCATED AT STRONG POINTSDOES NOT F BUILDING PL"rl2lit#: 1 1 `ti!I �✓3 0�/ ` METER NUMBER:24 533 940 COVER SHEET CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS � TREES,WIRES OR SIGNS. Add T sS' \ 01 �/ 1-7,e PV-1 Suite #: & By: ir7i Date: __4..._ 3 L; ar I`) .:;il 0; b an Its s : SCOPE OF WORK (N)4.920kW DC/3.900kW AC ROOF MOUNT PV SYSTEM CONTRACTOR INFORMATION (12)REC SOLAR REC410AA PURE(410W)MODULES (12)ENPHASE IQ8M-72-2-US(240V)MICROINVERTERS �.r/'k \ (1)) COMBINER IQ 4 TOTAL ARRAY AREA =239 SQ,FT PAT H TOTAL ROOF AREA =2503 SOFT %ARRAY AREA IN ROOF =9,54% (N)PHOTOVOLTAIC ARRAY ON MP-01 SUNPATH SERVICES LLC ADDRESS:9978 SOUTHWEST ARCTIC (N)JUNCTION BOX NEMA 4X RATED DRIVE,BEAVERTON,OR 97005 (N)CONDUIT RUN PHONE NUMBER:(503)313-7253 LICENSE NUMBER:OREGON CCB (N)ENPHASE IQ COMBINER 4(EXTERIOR) ,w ,''''4. o P 235715 (N)AC DISCONNECT(EXTERIOR) a S CUSTOMER INFORMATION OWESTTSRF A75%', (E)UTILITY METER(EXTERIOR) NAME:EVELYN GRAY (E)MAIN SERVICE PANEL (E)WALKWAY, (INTERIOR) ADDRESS:11078 SOUTHWEST 130TH (E)GATE', AVENUE,TIGARD,OR 97223 106.-8" COORDINATES: 45.439956, —4'-2" 122.810240 If r o,,„c(�� a O 0 0 APN:R2022191 '" 4.920kW DC / 3.900kW AC ROOF LEGEND L— Q �% MOUNT PV SYSTEM p � —I C � ° A SETBACK = DRIVEWAY o L Il/� PROPERTY LINE cn 1-1 I:° OI —0— FENCE AND GATE LINE W 51 8" / \ WALKWAY I,o 51'8" SKYLIGHT&CHIMNEY --I 23'-8" c - I% Kri �o ►=� (ROOF OBSTRUCTION) I VENT D �% n (ROOF OBSTRUCTION) Z o �--13 6"� (E)FENCE m N UM I UTILITY METER 3'-11" ® O O I MSP MAIN SERVICE PANEL Act AC DISCONNECT 106'8' y 1 CBI COMBINER BOX (N)(12)REC SOLAR REC410AA PURE(410W) (E)FENCE PROJECT ID AUR-83827 MODULES WITH ENPHASE IQ8M-72-2-US (E)PATIO ;B JUNCTION BOX (240V)UNDER EACH MODULE DATE 8/19/2023 (N)PHOTOVOLTAIC ARRAY ON MP-02 CREATED BY SB SIGNATURE @ SITE PLAN PV-2 1 SCALE:1/16"=1'-0" J WIND SPEED:105 MPH AND SNOW LOAD:25 PSF CONTRACTOR INFORMATION NO.OF ARRAY AREA ATTACHMENT ROOF FRAME FRAME MAX MAX S.NO AZIMUTH PITCH ROOF TYPE ATTACHMENT FRAME TYPE ATTACHMENT OVER MODULES (San) QUANTITY EXPOSURE SIZE SPACING SPACING HANG COMPOSITION SNAPNRACK ULTRA PRE-FABRICATED PATH MP-01 270° 26° 8 159.33 SHINGLE RAIL COMP KIT 26 ATTIC TRUSSES 2"X 4" 24"O.C. 4'-0" 1'-6" SUNPATH SERVICES LLC " MP-02 180° 26° 4 79.66 COMPOSITION SNAPNRACK ULTRA PRE-FABRICATED ADDRESS:9978 SOUTHWEST ARCTIC SHINGLE RAIL COMP KIT 14 ATTIC TRUSSES 2"X 4" 24'O.C. 4'-0" 1'-6 DRIVE,BEAVERTON,OR 97005 PHONE NUMBER:(503)313-7253 NOTE: LICENSE NUMBER:OREGON CCB 1.PENETRATIONS ARE STAGGERED. 235715 2.24"O.C.MAX ATTACHMENT SPACING WITHIN 3FT OF A RIDGE AND HIP. CUSTOMER INFORMATION NAME:EVELYN GRAY (N)ARRAY MP-01 ADDRESS:11078 SOUTHWEST 130TH (E)2"X 4"PRE-FABRICATED TRUSSES @ 24"O.C.SPACING AVENUE,TIGARD,OR 97223 (N)ALUMINUM RAILS COORDINATES: 45.439956, -122.810240 -9,-1" 10'-8" -1,-1" J11" APN:R2022191 4.920kW DC 13.900kW AC ROOF -o .-.- / MOUNT PV SYSTEM ❑ I1, / 1-11" } (Ii/'I(/J!i(Ii// 19-4" 8%4" 1 t t - ' - � / n LEGEND I • i t • 4 _ //CII SETBACK 1'-4"-t —2'�- ❑ / M ED MODULE (N)ARRAY MP-02 r T-5" 10' — -- (/'❑ — — -( IMAI 22' RAIL - �/ ❑ 1 • ATTACHMENT — j�❑ — ROOF FRAME PROJECT ID AUR-83827 SKYLIGHT&CHIMNEY E--- — i_ —1' DATE 8/19/2023 (ROOF OBSTRUCTION) —1' CREATED BY SB o VENT I (ROOF OBSTRUCTION) SIGNATURE 10"-11"— ® i— MOUNTING DETAILS PV-3 1 SCALE:3/32"=1'-0" CONTRACTOR INFORMATION PATH SUNPATH SERVICES LLC ADDRESS:9978 SOUTHWEST ARCTIC DRIVE,BEAVERTON,OR 97005 (N)SNAPNRACK ULTRA RAIL COMP KIT (E)COMPOSITION SHINGLE ROOF PHONE NUMBER:(503)313-7253 MEMBRANE (E)2"X 4"TOP CHORD 24"O.C. LICENSE NUMBER:OREGON CCB (N)SNAPNRACK UR-40 RAIL SPACING 235715 (N)SOLAR MODULE CUSTOMER INFORMATION NAME:EVELYN GRAY ADDRESS:11078 SOUTHWEST 130TH AVENUE,TIGARD,OR 97223 6"MAX COORDINATES: 45.439956, 122.810240 APN:R2022191 4.920kW DC / 3.900kW AC ROOF (E)ROOF DECKING MOUNT PV SYSTEM (N)FLASHING I 0 DEAD LOAD CALCULATIONS TOTAL BOM QUANTITY LBS/UNIT WEIGHT(LBS) ` '/ MODULES 12 45 540 ' MID-CLAMP 12 0.17 2.04 END-CLAMP 24 0.3 7.2 RAIL LENGTH 89 0.42 37.38 / SPLICE BAR 0 0.52 0 PROJECT ID AUR-83827 SNAPNRACK ULTRA 40 1.03 41.20 L _IDATE 8/19/2023 RAIL COMP KIT SCALE:NTS MICROINVERTER 12 2.38 28.56 (N)SNAPNRACK ULTRA RAIL COMP KIT CREATED BY SB TOTAL WEIGHT OF THE SYSTEM(LBS) 656.38 (N)STAINLESS STEEL 5/16"LAG BOLT MIN.2.5" SIGNATURE EMBEDMENT PILOT HOLE REQUIRED TOTAL ARRAY AREA ON THE ROOF(SQ.FT.) 239 STRUCTURAL DETAILS WEIGHT PER SQ.FT.(LBS) 2 75 (E)2"X 4"TOP CHORD Q 24"O.C. SPACING PV3.1 WEIGHT PER PENETRATION(LBS) 16.4 MODULE SPECIFICATIONS MICROINVERTER SPECIFICATIONS CONTRACTOR INFORMATION MODEL REC SOLAR REC410AA PURE MODEL ENPHASE IQ8M-72-2-US(240V) (410W) ) i PAT H MODULE POWER @ STC 410W POWER RATING 325W OPEN CIRCUIT VOLTAGE:Voc 49.4V SUNPATH SERVICES LLC MAX OUTPUT CURRENT 1.35A MAX POWER VOLTAGE:Vmp 42.2V ADDRESS:9978 SOUTHWEST ARCTIC SHORT CIRCUIT CURRENT:Isc 10.42A CEC WEIGHTED EFFICIENCY 97.5% DRIVE,BEAVERTON,OR 97005 MAX POWER CURRENT:Imp 9.72A MAX NO OF MICRO 11 PHONE NUMBER:(503)313-7253 INVERTERS/BRANCH LICENSE NUMBER:OREGON CCB TEMPERATURE COEFFICIENT:Voc -0.24%/"C 235715 MODULE DIMENSIONS:L x W x H 71.7"x 40"x 1.2" MAX DC VOLTAGE 60V CUSTOMER INFORMATION NOTE: (EXTERIOR) 1.MICROINVERTERS ARE RAPID SHUTDOWN COMPLIANT AS PER NEC 690.12. (E)12ondBv 1PH 6oriz NAME:EVELYN GRAY 2.THE AC DISCONNECT MUST BE WITHIN 10'OF THE BILLING METER. METER;PORTLAND - 3.INSULATED PIERCING TAPS USED FOR THE LINE SIDE TAP SHALL BE LISTED AND GENERAL ELECTRIC ADDRESS:11078 SOUTHWEST 130TH MARKED SUITABLE FOR USE ON THE LINE SIDE OF THE MAIN SERVICE PANEL IN CO © > AVENUE,TIGARD,OR 97223 ACCORDANCE WITH NEC 230.46. 24 533 940 UTILITY (ROOF EQUIPMENT) (GROUND LEVEL EQUIPMENT) --10'MAX— I I COORDINATES: 45.439956, (N)(12)REC SOLAR REC410AA PURE(410W)MODULES WITH (E)200A END FED MAIN (INTERIOR) -122.810240 (N)(12)ENPHASE IQ8M-72-2-US(240V) PANEL APN:R2022191 i \ / (1)BRANCH OF(8)MICROINVERTERS PER SIDEC TAP i 4.920kW DC / 3.900kW AC ROOF �/ \/ (1)BRANCH OF(6)MICROINVERTERS PER NEC TAP �a QZ MOUNT PV SYSTEM (EXTERIOR) )g m (N)ENPHASE IQ (EXTERIOR) � COMBINER 4 01 (N)60A AC 'gym (N)JUNCTION DISCONNECT 1ti BOX ... I 15A/2P `3 O/ 3 f1 (fr' U � sti • 20N2P (N)(2)30A 20A/2P FUSES —(N)ENPHASE IQ8M-72-2-US(240V) NEMA 4X RATED EATON DG222NRB MICROINVERTER PER MODULE JUNCTION BOX AC COMBINER WITH AC DISCONNECT (E)GROUNDING ENPHASE ID GATEWAY SWITCH FUSED, ELECTRODE X-IQ-AM1-240.4 60A,120/240V,2P, 120/240V,NEMA 3R INSTALL LOCKABLE,LOAD (2)20A 2P PV BREAKERS& BREAK RATED, , (1)15A 2P GATEWAY VISIBLE, BREAKER ACCESSIBLE 24/7 (ONLY FOR SOLAR,NO LOADS TO BE ADDED) PROJECT ID AUR-83827 DATE 8/19/2023 CONDUCTOR SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND CREATED BY SB 1 NONE (2)12 AWG ENPHASE Q CABLE NONE (1)6 AWG BARE COPPER,EGC SIGNATURE PER BRANCH CIRCUIT 2 3/4"EMT (4)10 AWG THHN/THWN-2,Cu NONE (1)6 AWG THHN/THWN-2,EGC SINGLE LINE DIAGRAM PV-4 3 3/4"EMT (2)6 AWG THHN/THWN-2,Cu (1)6 AWG THHN/THWN-2,Cu (1)10 AWG THHN/THWN-2,EGC DC VOLTAGE DROP IS INSIGNIFICANT BECAUSE OF MICROINVERTERS MOUNTED AT PV MODULES. CONTRACTOR INFORMATION PER ENPHASE TECHNICAL BRIEF ON CALCULATING AC LINE VOLTAGE RISE FOR IQ-SERIES MICROS WITH Q CABLE FOR CENTER TERMINATION OF ENPHASE IQ8M-72-2-US,240V,Q CABLE,BRANCH CIRCUIT AC DROP FOR 6 MICROINVERTERS END FED IS GIVEN AS 0.20%. PAT H SUNPATH SERVICES LLC AC CONDUCTOR RUN FROM JUNCTION BOX TO COMBINER IS 50 FT(EST). ADDRESS:9978 SOUTHWEST ARCTIC MICROINVERTER OUTPUT VOLTAGE IS 240V,1.35 X 6=8.10A DRIVE,BEAVERTON,OR 97005 (2 x 50 FT x 8.10A x 1.200/kFT x 100)/(1000FT/kFT x 240V)=0.40% PHONE NUMBER:(503)313-7253 LICENSE NUMBER:OREGON CCB 235715 AC CONDUCTOR RUN FROM COMBINER TO INTERCONNECTION IS 20FT(EST). CUSTOMER INFORMATION MICROINVERTER OUTPUT VOLTAGE IS 240V,1.35 X 12=16.20A NAME:EVELYN GRAY (2 x 20 FT x 16.20A x 0.490/kFT x 100)/(1000FT/kFT x 240V)=0.13% ADDRESS:11078 SOUTHWEST 130TH AVENUE,TIGARD,OR 97223 0.20%+0.40%+0.13%=0.73%TOTAL WORST CASE VOLTAGE DROP COORDINATES: 45.439956, -122.810240 APN:R2022191 4.920kW DC / 3.900kW AC ROOF MOUNT PV SYSTEM PROJECT ID AUR-83827 DATE 8/19/2023 CREATED BY SB SIGNATURE VOLTAGE DROP CALCULATIONS PV-4.1 i AC WIRE SIZING CALCULATIONS BASED ON FOLLOWING EQUATIONS OCPD CALCULATION CONTRACTOR INFORMATION REQUIRED CONDUCTOR AMPACITY: ALLOWABLE BACKFEED: INVERTER OUTPUT CURRENT•#OF INVERTERS=MAX CURRENT PER 690.8(A)(1)(e)•125% MAIN PANEL RATING =200A M� =MAX CURRENT PER 690.8(B)(1) MAIN BREAKER RATING =200A y� CORRECTED AMPACITY CALCULATIONS: LINE SIDE TAP 100%OF ALLOWABLE BACKFEED =200A PAT H DERATED CONDUCTOR AMPACITY PER 690.8(B)(2)=AMPACITY•TEMPERATURE DERATE FACTOR*CONDUIT FILL DERATE INVERTER OVERCURRENT PROTECTION: SUNPATH SERVICES LLC DERATED CONDUCTOR AMPACITY CHECK:MAX CURRENT PER 690.9(6)(1)< INVERTER OVERCURRENT PROTECTION =MICROINVERTER 0/P CURRENT•#OF DERATED CONDUCTOR AMPACITY MICROINVERTERS•CONTINUOUS LOAD(1.25) ADDRESS:9978 SOUTHWEST ARCTIC =(1.35.12)•1.25 DRIVE,BEAVERTON,OR 97005 =16.20'1.25 =20.25A PHONE NUMBER:(503)313-7253 PV OVERCURRENT PROTECTION =30A 2 20.25A LICENSE NUMBER:OREGON CCB 235715 PV BACKFEED 5 30A PV OVERCURRENT PROTECTION - CUSTOMER INFORMATION NAME:EVELYN GRAY ADDRESS:11078 SOUTHWEST 130TH AVENUE,TIGARD,OR 97223 COORDINATES: 45.439956, ELECTRICAL NOTES WIRE SIZE CALCULATIONS -122.810240 1. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER AMBIENT TEMPERATURE 34°C APN:R2022191 NEC 310.10(D). TAG 1:(AC) 4.920kW DC 13.900kW AC ROOF 2. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET REQUIRED CONDUCTOR AMPACITY(1.35.6.1.25) =10.12A MOUNT PV SYSTEM LOCATIONS PER NEC 310.10(C). CORRECTED AMPACITY CALCULATION(0.94.1•25) =23.5A 3. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 10.12A<23.5A(#12 AWG ENPHASE Q CABLE) 4. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. TAG 2:(AC) 5. BREAKER/FUSE SIZES PER NEC 240. REQUIRED CONDUCTOR AMPACITY(1.35.6.1.25) =10.12A 6. AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250.122. CORRECTED AMPACITY CALCULATION(0.94.0.8.35) =26.32A 7. THE AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON NEC 310.15(B)(1). 10.12A<26.32A(3/4"EMT,#10 AWG THHN/THWN-2,Cu) 8. MAX.SYSTEM VOLTAGE COEFFICIENT IS FROM MODULE MANUFACTURER OR NEC 690.7 TAG 3:(AC) WHEN MANUFACTURER COEFFICIENT UNAVAILABLE. REQUIRED CONDUCTOR AMPACITY(1.35.12.1.25) =20.25A 9. CONDUCTORS ARE SIZED PER NEC TABLE 310.16. CORRECTED AMPACITY CALCULATION(0.94*1•65) =61.1A 10. CONDUIT SHALL BE INSTALLED MINIMUM 7/8"FROM ROOF SURFACE. 20.25A<61.1A(3/4"EMT,#6 AWG THHN/THWN-2,Cu) PROJECT ID AUR-83827 DATE 8/19/2023 CREATED BY SB SIGNATURE ELECTRICAL CALCULATIONS PV-4.2 CONTRACTOR INFORMATION PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH CAUTION•MULTIPLE SOURCES A ---- - -- '.. ELECTRIC SHOCK HAZARD RATED ACOPERATING CURVOLTAGTE 16.20 VAC AC "OF POWER AC NOMINAL OPERATING VOLTAGE 240 VAC TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION ' = PAT H AC DISCONNECT,POINT OF INTERCONNECTION POWER TO THIS BUILDING IS ALSO LABEL LOCATION PER CODE:NEC 690.54 SUPPLIED FROM THE FOLLOWING SUNPATH SERVICES LLC AC DISCONNECT,POINT OF INTERCONNECTION PER CODE:NEC 690.13ADDRESS:9978 SOUTHWEST SOURCES WITH DISCONNECTS LOCATED DRIVE,BEAVERTON,OR 97005 ARCTIC WARNING:PHOTOVOLTAIC AS SHOWN PHONE NUMBER:(503)313-7253 POWER SOURCE LICENSE NUMBER:OREGON CCB LABEL LOCATION LABEL LOCATION (E)MAIN SERVICE- 235715 CONDUIT,PV COMBINER BOX POINT OF INTERCONNECTION PANEL(INTERIOR) (E)UTILITY METER(EXTERIOR) CUSTOMER INFORMATION PER CODE:NEC 690.31(D)(2) PER CODE:NEC 705.12(C) (N)AC DISCONNECT(EXTERIOR) _ PHOTOVOLTAIC il (EXTERIOR)E IQ COMBINER 4 NAME:EVELYN GRAY ADDRESS:11078 SOUTHWEST 130TH AVENUE,TIGARD,OR 97223 AC DISCONNECT �= LABEL LOCATION =MI COORDINATES: 45.439956, AC DISCONNECT,POINT OF INTERCONNECTION 12 -122.810240 PER CODE:NEC 690.13(B) APN:R2022191 SOLAR PV SYSTEM EQUIPPED. 1 4.920kW DC / 3.900kW AC ROOF WITH RAPID SHUTDOWN / MOUNT PV SYSTEM TURN RAPID SHUTDOWN SWITCH TO THE "OFF'POSITION TO SHUT DOWN PV SYSTEM (N)PV ARRAY AND REDUCE , SHOCK HAZARD '., E ) IN THE ARRAY 1 LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE:NEC 690.56(C) 11078 SOUTHWEST 130TH AVENUE,TIGARD,OR 97223 RAPID SHUTDOWN SYSTEM UTILIZES MICROINVERTERS LOCATED UNDER EACH SOLAR MODULE SWITCH FOR SOLAR PV NOTES LABEL LOCATION SYSTEM PANEL CE 1.PLACARDS SHALL MEET THE REQUIREMENTS LABEL LOCATION OF ARTICLES 690 AND 705,UNLESS PER CODE:NEC 705.10 AC DISCONNECT,PV COMBINER BOX OTHERWISE SPECIFIED PER LOCAL AHJ PER CODE:NEC 690.56(C)(2) REQUIREMENTS. 2.PLACARDS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED AND SHALL COMPLY WITH ANSI Z535.4-2011, PROJECT ID AUR-83827 PRODUCT SAFETY SIGNS AND LABELS. 3.PLACARDS SHALL BE PERMANENTLY AFFIXED DATE 8/19/2023 TO THE EQUIPMENT OR WIRING METHOD. 4.PLACARDS SHALL BE OF SUFFICIENT CREATED BY SB DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL BE SIGNATURE HANDWRITTEN. 5.PLACARDS SHALL NOT COVER EXISTING PLACARDS MANUFACTURER LABELS. PV-5 6.WARNING SIGNAGE TEXT SHALL BE MINIMUM 3/8"TALL. • CONTRACTOR INFORMATION , !; PATH REC ALPHA PURE SERIES ; RCC .- A . ,1--tIs1i REC IF-o) 1aL1.F SUNPATH SERVICES LLC a ADDRESS:9978 SOUTHWEST ARCTIC 132 half,:REC ne Itnc bf iN ellsw+M DRIVE,BEAVERTON,OR 97005 c4Rtypr ''''W'apluewag66n l224 m —. PHONE NUMBER:(503)313-7253 clue. 010(3z,m9 a 0w4 4+4-0 m , 0 m LICENSE NUMBER:OREGON CCB Becksneet Highly rawstam polymm(EWck1 1 Anoa add a pmtm m(blark) 235715 Fra ne F uz.mu _ sA luncNanboc 3-pare 6ypea gpde'ft f g R CUSTOMER INFORMATION lioia y., s ii b,MC 8K94/K51(4 nt') ? �nnect ertea nm1 f award caber 12 916(4 yPv 43 7 0le12m t j NAME EVELYN GRAY EN506b m omet,ons .i:x10sl2n(591831821x106..0tnmu85m) i' If ADDRESS:11078 SOUTHWEST 130TH 2022 weight 456,120sk& — -- AVENUE,TIGARD,OR 97223 Crgn. Made in 5ngapore oc WINNER - .- F«, ..t COORDINATES: 45.439956, „„. Paver Ou<pu[Pv„(Wp) 390 395 400 405 410 EC 6121520161EC61730 2015 UI 6173U 122.610240 Watt Class Sorting-IW) 0/.5 0/.5 0/.5 0/.5 0/.5 (EC 62804 PIO 1061701 Salt Ms[ 4 minalPawerVolleg.-Vw,(V) 40.6 410 41.4 41.8 422 EC 62716 Anraw�aResnence APN:R2022191 m NnmalPowerCamera 1,_,,AI 9 OL 61 964 967 969 9.,2 61730 Fie TypeCIa,e2 4.920kW DC / 3.900kW AC ROOF - -'- - N open Circuit Volt V,J14) a84 4&6 48,8 491 494 IEC62782 0vnamicMecnancaILoae MOUNT PV SYSTEM 1E061715-22015 14144e2(35440) Short C irmitCurrem-I.,.(A) 1038 1039 10.40 IC 41 Ip 42 IEC5'_321 Lead Rat,to Ro EU863j20(5 Poveer0e y(W/ft') 19.6 19$ 201 20.3 206 15014001,1509001.IEC 450011EC 62941 1 ail Pavel.. y(%) 211 214 216 219 .22 Power Output•P,,,,(WP) 297 301 305 308 312 NominalP V g-VM,.(V) 383 385 390 394 39.8 --'- io Nomua8Powerturrent-I,e,(A) 777 779 782 783 785 %,� ure. , ' 1bmMtMadMOpwaMglempwamr N•CIs2'CI. Open Mimi<Voltage V„(V) 456 458 460 463 466 Temperature coerficientof P,,,, 0.230rc Short CicutCunetlt•Is,5A) 838 939 940 &4I 942 Temperaturecoeffioentor Vk: -024%/C C 1 ) tact omper r oef,,,,,, 004%PC I e �!'�Imbgenl3 n Nsl lxere...vura•zae.mugdp�•w P, ttAne arcs ex.w.m, a Tne!e.pet.met ssn<4 ere n<o vawes M Operatiq¢I temperature. JOt_e85'C Sttdard RECPtoirve Panelspe,pallet 33 — Maximum system voltage. !000V "c=,..lbymREC No Yes Ves Panelsper 4086P/Mgficubecontwner. 792124p41ets) =. C gggagglarprof Biwa Manimwn teat laaelhontl' •700p PaIM6®s/R') Panes per 53 RlrurA� 891(27pN1 ) ' System5b All e25RW 25i00kW Maximum test load(marl 4000Pa(83.516 fi) Product Warranty(ys) 20 25 15 _ Maaser'es fuser sting; 25A Po4eoWamamyly4s) 25 25 25 •'' imval Inv/Irradiance performance of module atsIC - Ma.raersecunent. 25A labor WsrantY14m) 0 25 10 Annual Deem+ 98% 925 1 ' "' 'o,l attwal oeg.adanon ozs% ozs% 025% C Power n Veer 92% 92% 92% a lal 410 WP aH,..-F,-.-'I-.I �w.9,�1 Available from 25 YEAR . 20 L PROJECT ID AUR-83827 •U F 22.2% 1= LEAD-FREE f ,1996RECC g l g, p , REC PTELTD DATE 8/19/2023 6 n 1 R m 1 a A M r REC- a high r v P g a ow 20 s nA,e 14 REC `s CREATED BY SB 1 .. carbon fob t- ... has regional panels manufactures Headquartered N to operational I _alMilee63r3P M1eaJ9uartersrftgapore RECalsonas reg ono nub in North Ametca.Europa arid Asia Pacific pos!@re<groupcom coma recgrwpeon, rc SIGNATURE MODULE SPEC SHEET SS • CONTRACTOR INFORMATION I• II < PAT H e EN PHASE ® IQ8M and IQ8A Microinverters SUNPATH SERVICES LLC Commonly us.module...Pe W 280-480 eon-500 ADDRESS:9978 SOUTHWEST ARCTIC ea Module compettany 5d.-cell L an/IOshelt-c,s/rce20 banca- ll.BB-calf w/132 half and 72-cell/140 ban-cell DRIVE,BEAVERTON,OR 97005 L. alS M "`P"vottage rang* V 30-65 32 49 PHONE NUMBER:(503)313-7253 Cperafgrange r I6-58 • Me./Mu.start voltage v 22/58 LICENSE NUMBER:OREGON CCB as,Input DC voltage a 80 235715 Mau cmnMww Mart OC cure. a w — M.,.input DC,nort-o+owtcurrent A 25 CUSTOMER INFORMATION AUAmodYel 20 NAME:EVELYN GRAY . Pre...0...DC port II • • • OC port teats.curre 0oli ADDRESS:11078 SOUTHWEST 130TH I IR AN array coneg,raten ..Ungrounded array:No additional c see protection required:AC side promotion req..max'Oa per hanm circuit AVENUE,TIGARD,OR 97223 IR Poet output power VA 330 See Man continuous output paver Is 325 349 COORDINATES: 45.439956, Nominal(L-Uudtege/range y 240/211-1ed -122.810240 Alas.• nuou.outputcurrent a L35 1.05 APN:R2022191 IQ8M and IQ8A Microinverters Nominal frequency 1b In 4.920kW DC / 3.900kW AC ROOF • Our newest 108 Microinverters are the indu.trri flat microgrid-forming.software defined Easy mh»raM ea.ndeahery,enorrange ., 42-66 MOUNT PV SYSTEM venters wmh split-phase power conversion capability to convert DC power to AC _ AC u circuit reaarwe over 2 , power efficiently.The brain of the semiconductor based nncroimerter is our proprietary Lightweight and compact with plug-n 3 cycles ens • application specific integrated circuit(ASIC)which enables the mnroir,oeret to operate in play connectorsMax ones per 200(1-Cl beancn circuit( n • grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed •Power Lee Commu.utwn(PLC) digits logic and has superfast response times to changing loads and grid events.alleviating between components Teal Harmonic distortion •5% constraints on battery sizing ter home energy systems. .Faster installation with simple two-wire O.eraobage class AC port III • cabling AC portbctteedoarent ea 30 • IIIII WyloduXl""'"yNd henletY Pwsiemor sY lung i 1.0 •Produce power even When Me grbh 0rie-tedlewwhv4r(equsebbl 0.8S baring-o.e5 legging down. Peek ate eny 97.8 97.7•Moethan one mllEom WnsalOgM howl CEC weighted efepency 5 97.5 97 aF testing Pan of the F.-phase Energy System,108 OR Series Microinverters redefine right-tors power consumption ell BO Series Microinver tars integrate with the reiablity standards with more than one •Class StlpAl-Nwieted enclosure • lO Battery.ICI Gateway.and the Enphase pillion cumulative hours of power-on .Optimized for the latest high-powered - Ape monitoring and analysis software testing.enabling an industry-leading PV modules ambient temperature nine -14•Co.10•C(J0•F to HQ") limited warranty ohm to 25 years. Rotative Mlmiddy range d%to 100%(condensing) tAlorogrid- mlng OC Connector type Mad .I Complies With tlnlateetuWvarcedgrid KDimensions 212mm18.3')xlT5 mm18.9'),302mm i1.2'1 C) •aWPo to -Remote automatic updates for the Weght 1.084(238 ks1 latest grid requirements Cooling Wetural convection-nor it`ll Connect PV modules quick easily g85erias Microinverters are UL listedCar Configurable to eoppotewlde range Aeon,*ter wet lowbm we to 108 Series Microinverters using the espy Rapid Shutdown Equipment and• efgdprofiles Pollutiondegree P03 included 0-DCC-2 adapter cable with conform with various regulations.when •Meets CA Ride 21(1A 1741-SA)and IEEE plug-n-play MC4 connectors, 'metalled according to manufacturer's %4t.2018(1k t741-SB 3'Ed.) Enclosure Class IIdasbls-.wier.&cprsgson r..eeane polymeric eodaasee • nsiructiona. Environs category/UV exposure rating NEW Type e/outdoor _ PROJECT ID AUR-83827 roBw'°Eswrnra„'n°tp•nie'dr°pxnr.M CA Rub 21(M.iMI-Sa).UL 8210e-i.IEEE 151J3ga(UL In4r sa 3.Ed.),FCC Pen 1SC Ws 810Es-o003C ass ELAN/CsA-C222NO.1070.05 "..)a o.a.r.ween.Me(m c.leolws This product sULLiuseu PV RapishutdamEyipmwm end conbnnewi.NEC201a,IEC20R,end NEC 2020 sectbn890.12.nd C22F DATE 8/19/2023 'Only M.esraled e,mw snerenConorse cr enaULnel. sw..wa s«w..ml.«...n..r.t.n. 2018 Rub ed-218 Reed Shutdown of W Systems for AC A.G.conductors.when needled according b manufacturer,.vlrwbpna. meuand ices wpm ed,-vn..a.2avinerM.onon,v CREATED BY SB „e.ren ink ureraed brrcM��neli errra.., And other.se rm..of Pe..Enemyru.4e adma to dur, vuM,l2Apcca9 S.I.E V52o22t22] mre.xs /, tares oce revuramenn oeebromanrereerormcmh..`spec bacon era.. .1 I.05,000-03EN11520221227 SIGNATURE MICROINVERTER SPEC SHEET SS CONTRACTOR INFORMATION ( =1 PAT H IQ Combiner 4/4C , Enphase Networking MODEL NUMBER SUNPATH SERVICES LLC kg Combiner,* Iotmr+ktemmmnwc.aPsarodm.e eardl,rexaar era.n»a.aePVpmemulam yinD01rrslcnz2a30.6%) ADDRESS:9978 SOUTHWEST ARCTIC X4CLA n-240-4 andeorsumpt e,pSrnrkot.DSBa sae,raerawarshwdtdlnechnegaMraryandlDsraNmCamaEar2modie dll DRIVE,BEAVERTON,OR 97005 gwu.240-4(EEE1San30te dNewlcel __--- _--- ___-- -_-- O Gorobtlyen4G 60 C b a )G YPrinled...board lot mtograted revonuograde PV productionk g(ANSI CM 29 t 0 5, IQ Combiner 4/4C Ttre lQ Combiner 44C with IQ Gateway and a Mt z G a d g(z ) r bl c d (c ooeM M Ss a ow d PHONE NUMBER:(503)313 7253 Xa IC.ANSI X40 4c GI6E 10 .2018) lopostnal gradecell mudemY 60 rotoroloyert.1Am...tete 05,EaoadaM ,Ileo,a.n US Pe,Is a, m.re teade9nale rRlaar sem.in the naalat ea-)incudesa say.solar.Ned to match Me LICENSE NUMBER:OREGON CCB Integrated LTE-M1 cell modem(included 0Balt,and 10 System.o„trol./andto deflect beat only with Q(,'Onlblrlel 4C)consolidates ACCESSORIES AND REPLACEMENT PARTS(not included,order separately) 235715 SIMPOded iereewwtas -- 106.IDM OMIOD(Donptmem10ola kdcrp.wsawr tei OD et ter connect or equipment to a single CUSTOMER INFORMATION ..ammunc Kt I1lloscire It streamlines IQ Microin/eters and COMMS CEL OEM M106 5- -0 CEL OpFM- -06 SP 5 Syear S data uan SELLAIGGEM MI 06 SP 05 4G based STE Mk cellular modem5 year Sprint data ^a storage h .Nations by providing a consistent, EUM00EMM106,10s basedL ellularrnM wtt 5 year ATa dataoa NAME:EVELYN GRAY Ceo ittkekws SuppmnDEmenRR210.8R215.BR220BR2JgRR210 BR250..WBR260AVOMA breaker. pre wired solutionfor iesidential applications efaeoA-a24av (*call breaker,2 paa10k fawn BRnO &Dp1SA-2.2401,. ClecumbreWer,2 owe 1SA talon BR215 -^ w It afters up to four 2-pole input circuits and BRw1UA-2p-241ye Mama aeaku,2pae 20A.EatonBRrm ADDRESS:11078 SOUTHWEST 130TH ,,p + &.354 Pz4Ws CO SAaeeker.2pp4.15A,EebnBR295BMdtHsl down lawmen AVENUE,TIGARD,OR 97223 Eaton ER series bulbar assembly. LemocrA2P-240V-B CI..Imam..2pak 20d,Ewen MR2200001 MJAaowaktt auppat .e. ' PA-SOLARSM ELD ES Replacement oar sh edfor OGumbiner 4lac ,-,•r !• MAPLUG-1204 Accessory raQplwd.6oiva.w LP*e.rw.,awcanb 4/4Ctre001#SafMEPLa49 COORDINATES: 45.439956, • - atG NA-t.o lzsA Roldaown lot Mr Eatonor cult breaker:,with.crew. -122.810240 Smart WT200-$PLtTICT LAMP) Awn 01irl0A split coremwmu Veneamtwa APN:R2022191 ELECTRICAL SPECIFICATIONS •molVaeslo Gateway for com and control RkaB 4.920kW DC / 3.900kW AC ROOF •Includes Mobile Connect cellular modem MOUNT PV SYSTEM F ..:.».. (CELLMODEM-Mt-50 SP 05),-clutled only with stoma,voltage L2024WAC 60Na I` IQ Combiner4C Felon BR ewrtstAwh e,Dooa 125A at < •Includes solar shield to match Enphase IQ Battery May centmwusctrtet rater, 65A t k aesthetics and deflect heat .4.7°.FygsdarwmromP(YpyOomP111y1twpe) 64A tN ?•• -Supports W-Fi,Ethernet,or cellular connectivity Max ruse. rating(mama) RDA t;d - y, •Optional AC receptacle evadable for PLC bridge MoPePRraMIRMa5*.R 7mirerage) Iplo5aur 2roaREwon SR series OA5Wpmdeenyranan(DgamkenMy(804a_Wed) Provides production melerng and consumption Ma.tptalu nchereu Mee *rating rrpav DoA o dsvib d g neretorti95Ath OGaewaybeakernuueed� I'. monitoring #0sN.4r>nske 1BAIX t5Arsurq OE/SieTnwv/Ewmtrtt[gwed'.. "` Produttton metenno OT 200Asord core pe metalledantl woadto 01Gateway Simple MECHANICAL DATA ( fit __.. _._ MACAAM1-2404C --^- ,it t s e�;: -Mounts on single stud with centered brackets 323 cmxN 5anx 168 bm(14 TSN x19:5inx tan aj.NwgMrc52S cm(2tA6itd with moraine Weeks*, i54720ts) F, 1, •Supports bottom back and side condut entry weignr )5 kq;16.516s) P •Allows up to four 2-pole branch circuits for 240VAC AmMeataOrRR.D ro _ plug-to breakers?not rntge - JOYak46eC(dpus hetep) r rs( ) Coming N ure connection plus neat shed } L`. j •80S total PV or storage branch circuits Dtpb.wgewlromwresrrwbp OMdeIX tatmeertlhettNEMAtype 2R ptdycarPoreN camRuctbn wmsixes •20A to SOA breaker I<to A AWGconductors t' Reliable •60A breakerbranch moot At O AwG copper wneuc -Neutra•Mato l i v gund putout to NO CORP.conduAMC ctors el znducters 6,6 •Durable NR ILcertified NEMA type 3R enclosure •Aways N. cal code resul to for conductor same •Five-year limited warranty Male,..: tpmaooemewe(AM2feelt.. ; •Two years labor reimbursement program coverage LINTERNET CONNECTION OPTIONS included for both the IQ Combiner IOU .gpprpdWI FI NEC 8235 tip/n —' •Lk listed - •X2-Q AMi-240-4 and X2-IQ-AMl-240 4C Comply with Cellular GELLMORMA 06 SP 05 CELL OEM M J At 05 G b sed LTE-M ce u ar modem)Note thole ..Connect X2q-AM1.240 A(IEEF 15472m 9) NWlar modern srequredfa akEpnase Energy 5y.em talatons. IEEE 1547:2018(UL 1741•SB,3'^Ed) ERtemek'.. 4160..IEEEE02a,CWSE(eRCw6)UTPEtamwa .AaRac.Weef PROJECT ID AUR-83827 COMPLIANCE III . Ce"s8""°.I°c.°'"r"'r CARtINz,tlnnn-sp DATE 8/19/2023 IEEE 164T.281B•UL 174t Se.am et PR240-AM1:2d44.w%2 q-AMI240.4p CN/C&1C22 2 W 107.1,Tb42CFr6Pn15.aR5lPVCEB002 - I... �IS'rE0 Production mete.,ANSIC/236seevrtyefams0.5(PVpmPuwxwi}: ENPHASE. 5L0v 6 ANces Ede g` 52B_ To learn more about Enphase offerings,visit 000Rtiase.com v c mpliana.0 Gateway CREATED BY SB in-C-4 4C-DS 0103-EN-US 12 29-2022 -_ tr ��r e pia r. c 1,,tent r,r_ 1 rk _ ____�_ IQ-C.4 4C DS-0103-EN-US-1229-2022 SIGNATURE COMBINER SPEC SHEET SS c CONTRACTOR INFORMATION PATH DESCRIPTION: DRAWN BY _ DESCRIPTION: DRAWN BY SNAPNRACK,ULTRA RAIL COMP KIT mwatkins - ���� . I 1 SUNPATH SERVICES LLC 1 ..I `, SNAPNRACK,ULTRA RAIL COMP KIT mwatkins REVISION: " � "„� y REVISION: ADDRESS:9978 SOUTHWEST ARCTIC --__ _.._ -___ _-. F PART NUMBER(S): I x -- ._- PART NUMBER(S) �,. DRIVE,BEAVERTON,OR 97005 SEE BELOW I ,,,,w, ,„„",.„ .,. SEE BELOW ,�a .„ z,,,„.,, i PHONE NUMBER:(503)313-7253 1 LICENSE NUMBER:OREGON CCB UMBRELLA L FOOT PROPERTIES _-- 1 , 235715 � SKU DESCRIPTION 142 01220f ULTRA RAI UMBRELLA L FOOT,SILVER CUSTOMER INFORMATION _ 242 01219 ULTRA RAIL A 2 UMBRELLA L FOOT,BLACK, EVELYN GRAY .r Usk .38 NAME: 130TH U'% I AVENUE,TIGARD,OR 97223 .30 1.00 ADDRESS:11078 SOUTHWEST 1 �^ '�'� _ SLOT , , I -1� - 'I - 2.78 ._ COORDINATES: 45.439956,\ 1.50 .I�� _ 3.25 -122.810240 • �y �� ..: I 'i - .30 ( , , I APN:R2022191 11 �' COMP FLASHING PROPERTIES I` 1.80- �-1.50-� MOUNkWT DC 13.900kW AC ROOF MOUNT PV SYSTEM , SKU DESCRIPTION I ...,/ 1� 12", 232-01375 COMP FLASHING,9"X BLACK ALUM I 232-01376 COMP FLASHING,9"X 12",SILVER ALUM I— I \ „ ,2; ,232-01377 y COMP FLASHING,9"X 12",BLACK GALVALUME �F3 - '\ w� T - - - - - ���� a - .30 + " --01.00 ,2G[�,JQp, L fT a 6.75 •xvowsw 31 11.75 : PARTS UST _J—�, , ., 4.20 2 Q1Y - PART11 ,242-0 -77 SNAPNRACK COMP FLASHING,iE NOX 1FIN BLACK � I I l;5° ITEMI 1 242-92266 SNAPNRACK,UMBRELLA LAG,TYPE 3,4IN,SS 2 1 242-01219,242 01220 SNAPNRACK,ULTRA RAIL UMBRELLA L FOOT,_ SILVER/BLACK --- 3 1 z3z 01375,232-01376,232 013 -- - 0.35 1 -- y 1 PROJECT ID AUR-83827 DESIGNLOAD (LES): 802 2005 PUP, 1333 DOWN, 350 0 SIDE TERIALS: 6000 SERIES ALUMINUM, SS STEEL,RUBBER 3 5 u ;I I -- DATE 8/19/2023 D TORQUE SPECIFICATION: 12 LB FT ---- T -- CREATED BY SB CERTIFICATION: EIGHT�A ION: UL 2703,03LE E359313;WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 ALL DIMENSIONS IN INCHES 8.75 .45 ICI SIGNATURE 0. MOUNT SPEC SHEET SS 1. CONTRACTOR INFORMATION PATH Snapback' UR-40 SnapNrack Ultra Rail System Solar Mounting Solutions UR-60 A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail SUNPATH SERVICES LLC features two rail profiles:UR-40 is a lightweight rail profile that is suitable for most geographic ADDRESS:9978 SOUTHWEST ARCTIC Ultra Rail regions and maintains all the great features of SnapNrack rail,while UR-60 is a heavier duty rail DRIVE,BEAVERTON,OR 97005 profile that provides a larger rail channel and increased span capabilities.Both are compatible ""''•'""•"° •••. .•-••"""•*`• with all existing mounts,module clamps,and accessories for ease of install. PHONE NUMBER:(503)313-7253 LICENSE NUMBER:OREGON CCB 235715 The Entire System is a Snap to Install CUSTOMER INFORMATION •New Ultra Rail Mounts include snap-in brackets for attaching rail NAME:EVELYN GRAY •Compatible with all the SnapNrack Mid Clamps and End Clamps customers love ADDRESS:11078 SOUTHWEST 130TH Universal End Clamps and snap-in End Caps AVENUE,TIGARD,OR 97223 provide a clean look to the array edge ..,,. � .�._...�..,, ..._,,.,._.. .. COORDINATES: 45.439956, 122.810240 APN:R2022191 Unparalleled Wire Management •Open rail channel provides room for running 4.920kW DC / 3.900kW AC ROOF wires resulting in a long-lasting quality install MOUNT PV SYSTEM •Industry best wire management offering -_ includes Junction Boxes,Universal Wire "' Clamps,MLPE Attachment Kits,and Conduit a Clamps •System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard _ Industry leading Wire -. Mounts available for all ff ,,R Heavy Duty UR-60 Rail Management Solutions roof types •UR-60 rail profile provides increased span I capabilities for high wind speeds and snow Single Tool Installation All SnapNrack Module loads • stronger rail profile includes profile- Clamps & Accessories specific rail splice and end cap are compatible with •All existing mounts,module clamps,and I accessories are retained for the same great both raiil profiles install experience Start Installing Rail Today RESOURCES snapnrack.com/resources Quality. Innovative. Superior. DA�ECTID AUR-83827 DESIGN SnapnraCk.COm/ConflguratOr SnapNrack Solar Mounting Solutions are engineered to optimize material use and CREATED BY SB labor resources and improve overall installation quality and safety. WHERE TO BUY snapnrack.com/where-to-buy 877-732-2860 www.snapnrack.corn contact osnapnrack.corn SIGNATURE RAIL SPEC SHEET SS