Loading...
Report (15) (.. "CROSSING AT BULL MOUNTAIN" LOT 196 FOUNDATION CERTIFICATION SE 1/4 SEC. 8, - 2 S. R 1 W, W.M. C. TY OF liGARD. WASHINCTON COUNTY, OREGON SURVEYED SEPTEMBER 14, 2023 . PREPARED FOR: I/15'T 2o2-3"— 00(qq Ic-,!-! ,J0 USA 1509 SW SUNSET 2' VD. SUE 2-D PORTLAND, OR 97239 '5- 195 , < -7 -ie A & -, nyra2/I .,_, ci.ci — r) (NI "rtfrief re://)67 tri -CS '-. (13 29.44' 2922' N895553"E i 100.13' 2c•63' - • 1... _____ —, : , .., b u, o z i 0 cz) CNi i, Oj 3 0, •4' 1.1 tP me 20 _,.30' --- * --,4) csi • 0 N L, .i LOT 2 00' c -6 04 rn 10.00 196 .** 0 29.20' 4. r) p so .8 --• -22.30' ii- P u. o 15't P 0 ,-. i 0. o A' 39.20 I.. r, Lu • (on C4. Z , 38.63' 1.- 39 37.----- Cn ' 0 2 S89•5553"W t 100.12' 22 6, , (0 w H c PUBLIC L 0 T LI TiLi TY -5- f REGISTERED 1 97 EASEMENT cc PROFESSIONAL 73 LAND SURVEYORI u ... OREGON -----1------1 JULY 9, 2002 >. TRAVIS C. JANSEN 57751 ..1 v, .0 0 RENEWS: 6/30/2025 ., a .=-- I CERTIFY THAT I HAVE VERIFIED THE LOCATION OF THE SCALE §- 2 FOUNDATION UPON THE HEREIN DESCRIBED REAL PROPERTY 20 0 10 20 c1 AND THAT I FOUND THE IMPROVEMENTS AS SHOWN TO BE 15111n11. (7, 9 UPON THE PREMISES AS HEREIN DESCRIBED, AND IHEY DO 1 INCH = 20 FEET § NOT ENCROACH ON THE PROPERTIES ADJACENT THERETO. % DRAWN BY: TRK DATE:09/14/23 PACIFIC COMMUNITY DESIGN 9. RRviEWEn BY: T2 DATE:09/14/23 i PLANNING - ENGINEERING - SURVEYING ,i -zq_nr,,..1 k PROjECT NO.: -3- '-''-'' \ __. (503) 941-9484 ,1 GEAPACIFIC Real-World Geotechnical Solutions Investigation• Design •Construction Support September 11, 2023 Project No. 22-6162 Ichijo USA Co., LTD 'i' /5 7 Attn: Erik Gomez 1509 SW Sunset Blvd. Suite 2-D Portland, Oregon 97239 Via email to: erik.gomez(a�ichiiousa.com SUBJECT: FOUNDATION SUBGRADE REVIEW LOT 196R1VER TERRACE CROSSING AKA CROSSING AT BULL MOUNTAIN 15643 SW EVERGLADE AVE TIGARD, OREGON This letter addresses the single-family home foundation subgrade on Lot 196 of the River Terrace Crossing development, also known as Crossing at Bull Mountain. We understand that the proposed building is a two-story home with a crawl space. As part of this evaluation, GeoPacific visited the site on September 1, 2023 to observe the subgrade foundation preparation. At the time of our site visit, the foundation excavation was complete and was generally 6 to 18 inches below surrounding grades. A thin lift of gravel had been placed over the foundation subgrade soils as protective cover. Subgrade generally appeared to consist of engineered fill material. The engineered fill material ranged from stiff silt to dense silty gravel. The foundation layout of Lot 196 is stepped down to the southeast with two benches about 6 to 12 inches tall. Footing-to-wall and footing-to-slope setbacks did not appear to be an issue for the structure. There is an existing Lock+Load retaining wall in the rear yard, along the western property boundary, but it is at a sufficient distance and the grade between the house and the wall is relatively level. Based on observed conditions, foundation subgrades as prepared are considered suitable to support the planned allowable bearing pressure of 1,500 psf. Estimated settlement under the allowable bearing pressure is 1-inch total, and % inch differential, measured over a horizontal distance of 20 feet. Care should be taken to avoid saturation or disturbance of footing subgrade soils during and after excavation. If footing bearing soils become saturated or disturbed, any softened soil or slough should be removed and replaced with crushed aggregate or additional concrete. In general, footing excavations should be cleaned such that no more than approximately '/2-inch of loose soils are present prior to pouring concrete. Construction should include typical measures for controlling subsurface water beneath the homes, including positive crawlspace drainage to an adequate low-point drain exiting the foundation, visqueen covering the exposed ground in the crawlspace, and crawlspace ventilation (foundation vents). The homebuyers should be informed and educated that some slow flowing water in the 14835 SW 72nd Avenue Tel(503)598-8445 Portland,Oregon 97224 Fax(503)941-9281 GeoPacific Engineering, Inc. Job No.22-6162 Lot 196 River Terrace Crossing crawlspaces is considered normal and not necessarily detrimental to the home given these other design elements incorporated into its construction. Adequate crawlspace drainage is not something that geotechnical consultants can verify; the purpose of our visit is for observations of foundation bearing conditions only. Appropriate design professionals should be consulted regarding crawlspace ventilation, building material selection and mold prevention issues, which are outside GeoPacific's area of expertise. We have prepared this report for Ichijo USA, and it should not be relied upon by third parties without consulting GeoPacific. Within the limitations of scope, schedule and budget, GeoPacific attempted to execute these services in accordance with generally accepted professional principles and practices in the fields of geotechnical engineering and engineering geology at the time the report was prepared. The conclusions and interpretations presented in this report should not be construed as a warranty of the subsurface conditions. No warranty, expressed or implied, is made. The scope of our work did not include flood hazard evaluations, environmental assessments, the presence or absence of wetlands; or potential hazardous substances in the soil, surface water, or groundwater at this site. We appreciate this opportunity to be of service. Sincerely, GEOPACIFIC ENGINEERING, INC. Benjamin G. Anderson, P.E. Associate Engineer