Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit (5)
CITY OF TIGARD MASTER PERMIT 14 -0, COMMUNITY DEVELOPMENT Permit#: MST2023-00378 T I[,AR r 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/05/2023 Parcel: 2S104AC07300 Jurisdiction: Tigard Site address: 12679 SW MORNING HILL DR Subdivision: MORNING HILL NO.9 Lot: 216 Project: Berry Project Description: Rooftop solar system 4.8 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $11,280.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 4.8 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: BERRY,MICHAEL S&THERESA M LUMIO HX INC Required Items and Reports(Conditions) 12679 SW MORNING HILL DR 2500 MOTTMAN RD SW STE 100 TIGARD,OR 97223 TUMWATER,WA 98512 PHONE: PHONE: 360-777-6681 FAX: Total Fees: $328.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR ac _M1_nnln fhrnn AR 0c9_nn1_nnon Vro, n in a rnmi of the nilac nr rlirert ni ieetinne to(ll INC.by rallinn R(11 9't9 10517 nr 1 Ann 1'19 71.44 Issued By: Permittee Signature: % ' I C 03.639.4175 y 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR ol•FlcF,USE ONLY 'LOU'`}` Received ,,tt.. y� x City of Tigard �tj Date/By: Pem�il�¢y' `'�J�� Ilig13125 SW Hall Blvd.,Tigard,OR 97223 Plan ��,/Q� !V�, , Phone: 503.718.2439 Fax: 503.598.1961)` V I ' /" Other Permit: „I�" OF rlG i v Plan Review Z T I G n R n Inspection Line: 503.639.4175 I Date Ready/By: / z H See Page 4 for I Internet: www.tigard-or.gov 1)al.rt(.lIN(a DIVISION Notified/Method g/( r�/ i ' Il�' Supplemental Information 4. led j0 y6;:�. TYPE OF WORK :REQUIRED DATA:I-AND 2-FAMILY DWELLING ❑New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application.Valuation $11280.00 Qj ®1-and 2-family dwelling ElCommercial/industrial ElAccessory building El Multi-familyNumber of bedrooms: ❑Master builder ❑Other: Number of bathrooms: 4013 SITE INFORMATION AND LOCATION Total number of floors: Job site address:12679 SW Morning Hill dr New dwelling area square feet City/State/ZIP:Tigard, OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solar project-Berry Covered porch area square feet Cross street/directions to job site: Deck area square feet Other structure area: square feet REQUIREDDATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 4.8kwdc rooftop photovoltaic system valuation $ Existing building area: square feet New building area: square feet la PROPERTY"OWNER 0 TENANT " Number of stories: Name:Michael Berry Type of construction: Address:12679 SW Morning Hill dr Occupancy groups: City/StateiZlP:Tigard, OR 97223 Existing: Phone:(503 )703-1813 Fax:( ) New: APPLICANT g CONTACT PERSON BUILDING PERMIT FEES" Business name:LUMIO HX (Pi�eWe,klee'ska�0 Structural plan review fee(or deposit): Contact name:Jessica Paxton Address:1550 W Digital Dr. FLS plan review fee(if applicable): Total fees due upon application: City/State/ZIP:Lehi/UT/84043 Amount received: Phone:(360 )777-6681 Fax::( ) E-mail PNW.PERMITTING@LUMIO.COM ;PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:LU M I O HX Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:1550 W Digital Dr. Solar Installation Specialty Code checklist. City/State/ZIP:Lehi/UT/84043 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 360)777-6681 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:242553 Total fee due upon application $201.60 Authorized signature: � � D6U1>7� This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Tearua Downs Date:8/2/2023 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Electrical Permit Application ' FOR OFFICE USE ONLY Tigard Ut, .- Zth.. Received Per r ' � i71"'' �) City of Tigard Dateiv 111 'I 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review >s Phone: 503.718.2439 Fax: 503.598.1960 J I fi OF Ti l GAR L Date/B : Related Permit#: Inspection Line: 503.639.4175 Ready Date/By: luris: ® See Page 2 for TIGARD Internet: www.tigard-or.gov �.`i lLI.,)ING DI\,/lSIC Notified/Method: Supplemental Information r TYPE OF:WORK . '. s ,;.,.,.," ,PLAN,REVIEW ❑New construction ®Addition/alteration/replacement„ Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. ;'CATEGORY-;OF,CONSTRiICTION,.� r VU,.�� ,,.,„,,... exceeds 10,000 amps at 150 volts or 0 Floating buildings. � ,�f less to ground,or exceeds 14,000 ❑Commercial-use agricultural ® 1 and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑Multi-family 0 Master builder ❑Other: El Fire pump. 0 Installation of 150 KVA or JOB"SITE„INFORMATION";AND-,LOCATI,ON a o ,. �;;' 0 Emergency system. larger separately derived s, : . - system. "' ❑Addition of new motor load of Y Job#: Job site address:12679 Southwest Morning Hill Drive looHP or more. ❑..A","E","1-2 "1-3 ❑Six or more residential units. occupancy. City/State/ZIP:Tigard, Oregon 97223 0 Health-care facilities. ❑Recreational vehicle parks. ❑Hazardous locations. 0 Supply voltage for more than Suite/bldg./apt.#: Project name:Solar project- Berry 60o volts nominal. ❑Service or feeder 600 amps or more. Cross street/directions to job site: `.„ ° .x L,L. SCIEDTJLE„. ,„ , , ," Description I Q . I Each 1 Total New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1 DESCRIPTIONsOF WORK ) V:g „Ca , , Limited energy,residential 75.00 2 4.8kwdc rooftopphotovoltaic system (withd energy,above q. .) Y Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑ See Page 2 „<'®'PROPERTY;OWNER ,:=.f, .;; ,,,,❑ 'ENANT ,„try .-. Services olr feeders installation,alteration,and/or relocation Name:Michael Berry 200 amps or less 100.70 2 01 amps to 400 amps 133.56 2 Address: 12679 Southwest MorningHill Drive 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, Oregon 97223 601 amps to 1,000 amps 301.04 2 Phone:( 503)7031813 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: tberry@tpgrp.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 F ON Branch circuits—new,alteration,or extension,per panel "APPEICANi ©11ACIr 1 �„ ,..' A.Fee for branch circuits with Business name:LUMIO HX above service or feeder fee, 7.42 2 each branch circuit Contact name:Jessica Paxton B.Fee for branch circuits without service or feeder fee,first 56.18 2 Address:1 550 W Digital Dr. branch circuit City/State/ZIP:Lehi/UT/84043 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( ) Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:PNW.PERMITTING@LUMIO.COM Reconnect only 67.84 2 i';CONTRACTORU„ a R 3 w, „„ Pump or irrigation circle 67.84 2 Business name:LUMIO HX Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy ® See Page 2 2 Address:1550 W Digital Dr. panel,alteration,or extension. Each additional inspection over allowable in any of the above City/State/ZIP:Lehi/UT/84043 Additional inspection(1 hr min) 66.25/hr Phone:(360)7776681 Fax:( ) Investigation(1 hr min) 90.00/hr Email:PNW.PERM ITTI NG@LU M IO.COM Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.:242553 Electrical Lic.:C 1757 Suprv.Lic.:6716S specifically listed('V5 hr min) ', :., , "E CrI CALflR II T,FEES ..w i m.,.. Suprv.Electrician signature,required:5 , , . Subtotal: Print name: Bryson Jeffs I�ate:8/2/2023 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): TOTAL PERMIT FEE: Authorized signature: iJ ,y This permit application expires if a permit is not obtained within 180 Print name: Jessie22,„yezzaa, xton Date:8/2/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. C\Building\Permits\ELCPermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB - Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL,WORK ONLY ,i ,,t f. FE SC Qtr.ILE .``N ._ Qty. I Each I Total *. Description I . Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 1 100.70 2 Check Type of Work Involved: 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed('/2 hr min) colvrnlERCIAIJ wP :NI Y ww n %' ;*** .E ECr�UIG 1°l Jtltmq Es Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 + Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermitApp_ELRERE.doc Rev 06/17/2015 RECEIVE-1) City of Tigard q BuildingDivision „AD OF TIGARL 13125 SW Hall Blvd,Tigard,OR 97223 -}r..11l �iNG.,1 � a �flliSlON Phone: 503.718.2439 Fax: 503.598.1960 T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address:12679 Southwest Morning Hill Drive City: Tigard, Oregon Zip: 97223 Owner's Name: Michael Berry Date:8/2/2023 Contractor's Name: LUMIO HX CCB #: 242553 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Located in a flood prescriptive path, follow Area plain/flood way? ® No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for p "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above ❑ No 1 I:Building/Forms/Photo V oltai c-Checklist02-01-11.docx Is the construction Type of material wood and does ® Yes If"Yes", Yes , qualifies for the construction qualify ❑ No the prescriptive path. Construction as"conventional light frame" construction? Is the spacing 24 inches or less? If"Yes", qualifies for Pre-engineered trusses. ® Yes the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. ® Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. • of composition shingle. Is the roof mounted Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:Building/Forms/Photo Voltaic-Checklist02-01-11.docx VI Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ® Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2"thickness, ® Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/Photo Voltaic-Checklist02-01-11.docx r • Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:Q CELL Q. PEAK DUO Model Number:BLK M L-G1 0+(400W) Listing Agency: 4 I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx