Plans
A • B • C • D • E • F ■ G ■ H SHEET LIST TABLE E -�f !.lif!r i Li,GENERAL NOTES TLE NEW Pv SYSTEM: 10.080 kWp SHEET SHEET COVER PAGE1 4e, 2 # `4 '� 1.1.1 PROJECT NOTES: 1r 1.1.2 THIS PHOTOVOLTAIC(PV)USYSTEM SHALL COMPLY WITH THEA NATIONAL ELECTRIC CODE(NEC) BRYAN COOK RESIDENCE G 2 NOTES � ■ ARTICLE 690, ALL MANUFACTURERS'S LISTING AND INSTALLATION INSTRUCTIONS, AND THE B� E `-d`1` - -`°�' ■ RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE PV-1 SITE PLAN CODES. 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PV-2 SOLAR RACKING PLAN PRIOR TO PARALLEL OPERATION. 1.1.4 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE 14590 SOUTHWEST 87TH PV-3 ASSEMBLY DETAILS CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS PV-4 ELECTRICAL PLAN AS REQUIRED BY NEC 690.4&NEC 690.60:PV MODULES:UL1703,IEC61730,AND IEC61215,AND AVENUE SIGNED OR 97224 FOR OFFICIAL USE 2 TYPE 1 FIRE RATING INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519 COMBINER BOX(ES): PV 5 LINE DIAGRAM UL 1703 OR UL 1741 ACCESSORY.PV MOUNTING SYSTEM: UL2703, AND CLASS A FIRE ASSESSOR'S #: 2S111AD00800 RATED PER UL 2703. PV-6 DESIGN TABLES 1.1.5 NEC 690.35 REFERS SPECIFICALLY TO"UNGROUNDED"PV POWER SYSTEMS.ALSO 1 DESIGNATED AS"TRANSFORMERLESS"BY INVERTER MANUFACTURERS AND"NON-ISOLATED"BY PV-7 PLACARDS&LABELS UNDERWRITERS LABORATORY. ,d- 1 1 1.1.6 INVERTER(S)USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE[NEC 690.35(G)]. " " PV-8 RESOURCE SHEET ■ 1.1.7 AS SPECIFIED BY THE AHJ,EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDING PV-9 RESOURCE SHEET ■ TO NEC 690.35(F). k 1.1.8 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR * VOC.IF UNAVAILABLE,MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. ' aIk PV-1 0 RESOURCE SHEET 1.1.9 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS. PHOTOVOLTAIC “- r PV-11 RESOURCE SHEET MOUNTING SYSTEMS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A - PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(D).SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR 3 PROJECT INFORMATION ;.,� LABELING[NEC 110.3]. " " 1.1.10 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE.IF EXPOSED TO OWNER SUNLIGHT,IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS ''pe'`' i k e NAME: BRYAN COOK REQUIRED BY THE NEC AND AHJ. xOr' - "` PHONE: (303)859-5265 1.2.1 SCOPE OFWORK: AERIAL PHOTO 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED 0 PROJECT MANAGER ■ PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR NAME: CHARLES BONVILLE Is COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE NOT TO SCALE PHONE: 503-874-4142 EXT 159 EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. Approved Imo' CONTRACTOR 7 Chaff be on job site. NAME: EARTHLIGHTTECHNOLOGIES 1.3.1 WORK INCLUDES: PHONE: 503-874-4142 EXT 159 1.3.2 PHOTOVOLTAIC MOUNTING SYSTEMS-IRONRIDGE HALO ULTRA GRIP 4 1.3.3 PV RACKING SYSTEM INSTALLATION-SUNPOWER INVISIMOUNT 1.3.4 PV MODULE AND INVERTER INSTALLATION-(28)SUNPOWER SPR-X22-360-E-AC SOLAR MODULES OFFICE COPY jA AUTHORITIES HAVING JURISDICTION iC / BUILDING: TIGARD CITY,OR 1.3.5 PV EQUIPMENT GROUNDING 1 • ZONING: TIGARD CITY,OR 1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX ,, =1 UTILITY: PGE 1.3.7 PV LOAD CENTERS(IF INCLUDED) 1.3.8 PV METERINGIMONITORING(IF INCLUDED) {� w '7 o DESIGN SPECIFICATIONS 1.3.9 PV DISCONNECTS CITY OF 'TIC,, s .�T, a ■ 1.3.1E PV FINAL COMMISSIONING CONSTRUCTION: SINGLE-FAMILY RESIDENTIAL ■ 1.3.11 (E)ELECTRICAL EQUIPMENT RETROFIT FOR PV I2 E:VT ��'�� ` C �= r� LLAI*�C cp _ _ �., .- WIND SPEED: 110 MPH 1.3.12 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE Approved: t il Z RISK CATEGORY: II WIND EXPOSURE OTC: I l 2 cla : VALIDITY OF PERMIT CATEGORY: B SCOPE OF WORK r- a'23 GROUND SNOW LOAD: 25 PSF SYSTEM SIZE: STC:(28)X360W=10.080kW I'crn�it#; M 7 _ m THE ISSUANCE OF A PERMIT 5 PTC: (28)x 334.3W=9.360kW "� ,�, N ; BASED ON CONSTRUCTION ROOF ASSEMBLY FIRE (28)SUNPOWER SPR-X22-360-E-AC MODULES Address: PLAT MAP I DOCUMENTS AND OTHER CLASS RATING: A Suite #: r� w E DATA SHALL NOT PREVENT OCCUPANCY GROUP: R-3 Date: 5 2� 23 L THE CODE OFFICIAL FROM By: 0 NOT TO SCALE APPLICABLE CODES&STANDARDS ATTACHMENT TYPE. IRONRIDGE HALO ULTRA GRIP S REQUIRING THE CORRECTION 2021 OESC&2022 OSSC MSP UPGRADE: NO OF ERRORS.ORSC 105.4 ■ ■ CONTRACTOR COVER PAGE EARTHLIGHT TECHNOLOGIES 4,4,+, BRYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: 6 812 McCLAINE ST "` RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES PHONE:SI 5 3-8 4-4142N,OR 1EXT 159 �a��/� e a rt h I i g h t 14590 SOUTHWEST ASSESSOR'S#:2S18 AD OVEN 7TH AVENUE,TIGARD,OR 97224 G-1 CONTRACTOR LICENSE:201408 44"�.!��� SOLAR F v ENERGY SO.,T} S PHONE:(303)859-5265 DRAWN:KO CHECKED:DA REV:PERMIT SET DATE: 05/09/23 A . B . C ■ D ■ E 'I F .1- G • H A • B • C • D • E • F • G ■ H 2.1.1 SITE NOTES: 2.5.1 INTERCONNECTION NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.5.2 705.11 SUPPLY SIDE SOURCE CONNECTIONS:AN ELECTRIC PRODUCTION SOURCE,WHERE CONNECTED ON THE SUPPLY 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO SIDE OF THE SERVICE DISCONNECTING MEANS AS PERMITTED IN 230.82(6),SHALL COMPLY WITH 705.11(A)THROUGH(E). 1 STORAGE BATTERIES. 2.5.3 705.12 LOAD SIDE SOURCE CONNECTIONS:SHALL BE IN COMPLY WITH NEC 705.12(A)THROUGH(E).THE OUTPUT OF AN 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. INTER-CONNECTED ELECTRIC POWER SOURCE SHALL BE PERMITTED TO BE CONNECTED TO THE LOAD SIDE OF THE 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S)AT ANY DISTRIBUTION EQUIPMENT OF THE PREMISES.WHERE PROVIDED AS PER SECTION NEC 110.26. DISTRIBUTION EQUIPMENT OR FEEDERS ARE FED SIMULTANEOUSLY BY A PRIMARY SOURCE OF ELECTRICITY AND ONE OR ..■ 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE MORE OTHER POWER SOURCE AND ARE CAPABLE OF SUPPLYING MULTIPLE BRANCH CIRCUITS OR FEEDERS,OR BOTH,THE IN APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR INTERCONNECTING EQUIPMENT SHALL COMPLY WITH 705.12(A)THROUGH(E).WHERE A POWER CONTROL SYSTEM(PCS)IS STRUCTURE. INSTALLED IN ACCORDANCE WITH 705.13, THE SETTINGS OF THE PCS CONTROLLER SHALL BE CONSIDERED THE POWER-SOURCE OUTPUT CIRCUIT CURRENT IN 705.12(A)THROUGH(E). 2.2.1 EQUIPMENT LOCATIONS 2.5.4 NEC 705.12(A)DEDICATED OVERCURRENT AND DISCONNECT. 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. NEC 705.12(B)BUS OR CONDUCTOR AMPERE RATING:THE POWER SOURCE OUTPUT CIRCUIT CURRENT MULTIPLIED BY 125 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS PERCENT SHALL BE USED IN AMPACITY CALCULATIONS FOR 705.(B)(1)THROUGH(B)(3). FOR OFFICIAL USE 2 SPECIFIED BY NEC 690.31,AND NEC TABLES 310.15(B)(2)AND 310.15(C)(1). NEC 705.12(B)(1)FEEDERS.NEC 705.12(B)(2)TAPS.NEC 705.12(B)(3)BUSBARS.NEC 705.12(C)MARKING.705.12(D)SUITABLE 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. FOR BACKFEED.705.12(E)FASTENING. 2.2.4 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING NEC 705.12(B)(3)(1)THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF DISCONNECT. THE OCPD PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. NEC 705.12(B)(3)(2)WHRE TWO SOURCES,ONE PRIMARY AND ANOTHER POWER SOURCE,ARE LOCATED AT OPPOSITE ENDS FOR ALL PV 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. OF A BUSBAR THAT CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) DEVICE'S"OFF"POSITION SHALL INDICATE THAT THE RAPID SHUTDOWN FUNCTION HAS BEEN INITIATED OUTPUT CIRCUIT CURRENT SYSTEMS CONNECTED TO THAT DEVICE.FOR ONE AND TWO-FAMILY DWELLINGS AN INITIATION DEVICE(S)SHALL BE AND THE RATING OF THE OVERCURRENT PROTECTIVE DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT LOCATED AT A READILY ACCESIBLE LOCATION OUTSIDE THE BUILDING. II • 2.3.1 STRUCTURAL NOTES: OF THE AMPACITY OF THE BUSBAR. 2.3.2 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS NEC 705.12(B)(3)(3)THE SUM OF THE APERE RATINGS OF ALL OCPDS ON PANELBOARDS,BOTH LOAD AND SUPPLY DEVICES, 2 7 6 FOR A SINGLE PV SYSTEM,THE RAPID SHUTDOWN INITIATION SHALL OCCUR BY THE OPERATION OF ANY SINGLE INITIATION REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EXCLUDING THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR,SHALL NOT EXCEED THE AMPACITY OF DEVICE.DEVICES SHALL CONSIST OF AT LEAST OR OF THE FOLLOWING:(1)SERVICE MEANS,(2) EITHER EDGE OF THE ARRAY/SUBARRAY,ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. THE BUSBAR.PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT DISPLAYING THE FOLLOWING DEICE.DEM DISCONNECTING MEANS,OF AT(3)LREAS ILOACCESIBLEONEMORE SWITCH THAT PLAINLY(IN SERVICE DISCONNECTINGIT IS IN THE N "OR MEANS, 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS.IF ROOF-PENETRATING TYPE, IT SHALL BE OR EQUIVALENT WORDING:"WARNING:THIS EQUIPMENT FED BY MULTIPLE SOURCES.TOTAL RATING OF ALL OVERCURRENT FLASHED&SEALED PER LOCAL REQUIREMENTS. PROTECTIVE DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT PROTECTIVE DEVICE SHALL NOT EXCEED AMPACITY OF POSITION. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WI APPROVED CHEMICAL SEALANT PER BUSBAR" 3 CODE BY A LICENSED CONTRACTOR. 2.5.5 NEUTRAL CONDUCTOR USED SOLELY FOR INSTRUMENTATION,VOLTAGE, DETECTION,OR PHASE DETECTION SHALL BE 2.8.1 WIRING&CONDUIT NOTES: 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING PERMITTED TO BE SIZED IN ACCORDANCE WITH 250.102 PER 705.28(C)(1). P 8 2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE MANUFACTURER. 2.3.6 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.6.2 690.13 PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS SHALL BE PROVIDED TO DISCONNECT PV SYSTEM FROM ALL 2.8.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8. 2.4.1 GROUNDING NOTES: WIRING SYSTEMS INCLUDING POWER SYSTEMS, ENERGY STORAGE SYSTEMS, AND UTILIZATION EQUIPMENT AND ITS 2.8.4 EXPOSED UNGROUNDED PV SOURCE AND OUTPUT CIRCUITS SHALL USE WIRE LISTED AND IDENTIFIED AS PHOTOVOLTAIC 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EXPOSED TO THE ASSOCIATED PREMISES WIRING. (PV)WIRE 690.31(C). ELEMENTS SHALL BE RATED FOR SUCH USE. 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE (WHERE REQUIRED), AND BE A 2.8.5 PV WIRE SHALL BE IDENTIFIED AT THE TIME OF INSTALLATION PER NEC 200.6(A)(5). ■ 2.8.6 MODULE WIRING SHALL BE LOCATED AND UNDER THE ARRAY. IN 2.4.3 AS IN CONVENTIONAL PV SYSTEMS,UNGROUNDED PV SYSTEMS REQUIRE AN EQUIPMENT GROUNDING CONDUCTOR.ALL VISIBLE-BREAK SWITCH. WHEN ACCESIBLE TO UNQUALIFIED PERSONS THE DISCONNECT SHALL BE LOCKED OR REQUIRED 2 8 6 MODULEC WIRING SHALL COLORED OR MARKEDD A SECURED FOLLOWS:U METAL ELECTRICAL EQUIPMENT AND STRUCTURAL COMPONENTS BONDED TO GROUND,IN ACCORDANCE WITH 250.134 OR A TOOL TO OPEN. 250.136.ONLY THE DC CONDUCTORS ARE UNGROUNDED. 2.6.4 PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BATHROOMS PER NEC 690.4(E) PHASE A OR L1-BLACK 2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND NEC 690.45. 2.6.5 690.15 ISOLATING DEVICE FOR PV EQUIPMENT: DISCONNECTING MEANS SHALL BE PROVIDED TO DISCONNECT AC PV PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE 2.4.5 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURE CONSIDERED GROUNDED IN ACCORD WITH MODULES,FUSES,DC-TO-DC CONVERTERS,INVERTERS AND CHARGE CONTROLLERS FROM ALL CONDUCTORS THAT ARE PHASE C OR L3-BLUE,YELLOW,ORANGE*,OR OTHER CONVENTION 250.134 AND 250.136. NOT SOLIDLY GROUNDED.THE ISOLATING DEVICE SHALL BE ONE OF THE FOLLOWING:A MATING CONNECTOR,A FINGER NEUTRAL-WHITE OR GREY 4 2.4.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND SAFE FUSE HOLDER,AN ISOLATING DEVICE THAT REQUIRES A TOOL TO PLACE THE DEVICE IN OFF POSITION,AN ISOLATING IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE[NEC 110.15). APPROVED BY THE AHJ. IF WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED DEVICE LISTED FOR THE INTENDED APPLICATION. GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. 2.6.6 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.9,AND 240. 2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT 2.6.7 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED, THEREFORE BOTH REQUIRE OVER-CURRENT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. PROTECTION,ACCORDING TO NEC 240.21. I 2.4.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED GREEN OR MARKED GREEN IF#4 AWG OR 2.6.8 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. LARGER NEC 250.119 ▪ 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106.IF EXISTING SYSTEM 2.7.1 RAPID SHUTDOWN OF PV SYSTEMS ON BUILDINGS NOTES: 11 IS INACCESSIBLE,OR INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 2.7.2 RAPID SHUTDOWN APPLICABLE TO SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN AND AHJ. FUNCTION TO REDUCE SHOCK HAZARD FOR FIRE FIGHTERS IN ACCORDANCE WITH 690.12(A)THROUGH(D).EXCEPTION: 2.4.10 ACCORDING TO NEC 690.47(A)THE PV ARRAY EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED PER NEC 690.45 AND GROUND MOUNTED PV SYSTEMS THAT ENTER BUILDINGS,OF WHICH THE SOLE PURPOSE IS TO HOUSE PV SYSTEM 250.122. EQUIPMENT,SHALL NOT BE REQUIRED TO COMPLY WITH NEC 690.12. 2.4.11 ACCORDING TO NEC 690.47(B)ADDITIONAL GROUNDING ELECTRODE SHALL BE PERMITTEDTO BE INSTALLED IN 2.7.3 690.12(B)(1)OUTSIDE THE ARRAY BOUNDARY.CONTROLLED CONDUCTORS LOCATED OUTSIDE ARRAY BOUNDARY OR MORE ACCORDANCE WITH 250.52 AND 250.54.GROUNDING ELECTRODE SHALL BE PERMITTED TO BE CONNECTED TO PV MODULE THAN 1 M(3FT)FROM THE POINT OF ENTRY INSIDE A BUILDING SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 5 FRAME. SECONDS OF RAPID SHUTDOWN INITIATION TO LESS THAN 30 VOLTS WITHIN 30 SECONDS AFTER SHUTDOWN INITIATION. 2.4.12 IN UNGROUNDED INVERTERS, GROUND FAULT PROTECTION IS PROVIDED BY"ISOLATION MONITOR INTERRUPTOR,"AND VOLTAGE SHALL BE MEASURED BETWEEN ANY TWO CONDUCTORS AND BETWEEN ANY CONDUCTOR AND GROUND. GROUND FAULT DETECTION PERFORMED BY"RESIDUAL-CURRENT DETECTOR." 2.7.4 690.12(6)(2)(2)INSIDE THE ARRAY BOUNDARY.CONTROLLED CONDUCTORS LOCATED INSIDE THE BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION.VOLTAGE SHALL BE MEASURED BETWEEN ANY TWO CONDUCTORS AND BETWEEN ANY CONDUCTOR TO GROUND. 2.7.5 INITIATION DEVICE.THE INITIATION DEVICE(S)SHALL INITIATE THE RAPID SHUTDOWNFUNCTION OF THE PV SYSTEM.THE IN CONTRACTOR NOTES EARTHLIGHT TECHNOLOGIES •. B RYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: 812IL McCLSILVERTON, E 9T '4", al l e a rt h I i h t RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION P8 -2 6 SILVERTON,OR 97381 Iik '`� � 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 ( )SUNPOWER SPR-X22-360-E-AC MODULES G PHONE:503-874-4142 EXT 159 1f�/ ASSESSOR'S#:2S111AD00800 CONTRACTOR LICENSE:201408 +.�imir' SOLAR AN )ENERGY sOL L1TONs PHONE:(303)859-5265 DRAWN:KO DATE: CHECKED:DA REV:PERMIT SET 05/09/23 A • B • C • D • E • F • G • H A • B • C • D • E • F • G • H 7--- - - -----\ 1 / / I _■ / I ■ / / \ I / I 2 / ' I\e/ FOR OFFICIAL USE PROPERTY LINE / / GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS / 0 I 2. ITEMS BELOW MAY NOT BE ON THIS PAGE II / ■ AREA OF WORK / 43'_3" -_____-__- PROPERTY LINE / HOUSE I / I 3 ARRAY 1-10.08 kW F C I [x28](N)MODULES / TILT:18 DEGREES 0 ROOF PITCH:4:12 / 49'-7" AZIMUTH:269 DEGREES / I_ 1 I 0 INTERIOR ELECTRICAL EQUIPMENT ENTRANCE / II / I 0 (E)MAIN SERVICE PANEL ■ / ( 1 00 1 1 0 4 0 0 0 0 1 o DRIVEWAY 32T_411 0 I ■ m -� IIco 1. 5'-9IT J co — — zEXTERIOR ELECTRICAL EQUIPMENT ,T (E)UTILITY METER (N)AC DISCONNECT 5 (N)AC COMBINER PANEL (N)SUNPOWER MONITORING SYSTEM PVS6 SITE PLAN N O1W I E 1/16"7.1'-0" 0 16'' ■ s ■ CONTRACTOR SITE PLAN EARTHLIGHT TECHNOLOGIES •`� B RYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: 812 McCLAINE ST •• 6 SILVERTON,OR 97381 `"qt RESIDENTIAL SOUTHWEST 87TH INTERACTIVE TIGARD,IN OR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES ' PHONE:503-874-4142 EXT 159 ea rt h light Pv_1 CONTRACTOR LICENSE:201408 .,t•���, s ASSESSOR'S#:2S111AD00800 ..� SOLAR ANL ENERGY SO UTC'NS PHONE:(303)859-5265 DRAWN:KO DATE: CHECKED:DA REV:PERMIT SET 05/09/23 A • B • C • D - E • F • G • H A ■ B ■ C • D • E • F • G • H 1 I FOR OFFICIAL USE 2 GENERAL NOTES O 1. FIELD VERIFY ALL MEASUREMENTS. 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ■ O — — — — — ROOF P.E.TRUSSES ■ "/// FIRE CLEARANCE HOUSE O j 47'-2"L. O SQUARE FOOTAGE OF ROOF(PLAN VIEW)=2629 SF 2'-6" SQUARE FOOTAGE OF ARRAY (PLAN VIEW).467 SF 3 PERCENTAGE OF ROOF COVERED BY THE ARRAYS=18% O O O 0 1'-8" ARRAY AREA<25%OF ROOF AREA v . X 7/.%/1///7/7, ,// /i:"/W ///)7/,y 0 ;',////7 /4 1'-0" FIRE ACCESS PATH ■ 1I 1 1 1 4;0 —.1 ' j ; 1 1 b 6 1--N-- b 1 I 1 ROOF ATT. TYP. @48" MAX. I 1 I ' I I I , ' 17'-1" I e 1 l 1 I I I I i 1 I 1 I I I , I 1 i I i l I i I I I FLUSH MOUNT SOLAR MODULES Q Q o T ® TT ! ! q Q Q ATTACHED TO ROOF SURFACE(SEE SHEET PV-3 FOR MOUNTING DETAILS) I I I I I I I 1 1 I I l I 2'-0" ROOF MATERIAL IS COMP.SHINGLE II ROOF ATT. TYP. @24" MAX. 2"X4" P.E. TRUSS @24" O.C. ANY WITHIN 3' ROOF LINE SOLAR RACKING PLAN w 5 ' 01z_ . 11s"=1'0" 0 81 1 ■ ■ SOLAR RACKING PLAN 1 CONTRACTOR •0, BRYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: EARTHLIGHT TECHNOLOGIES e4 6 812SIL ERTOMcCLAINE ST A �� I I RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES PV-2 SILVER TON,OR 97381 ," ,..�,r/' e g 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 PHONE:503-874-4142 EXT 159 1�� ASSESSOR'S#:2S111AD00800 CONTRACTOR LICENSE:201408 a`r r SOLAR F :ENERGY S C S PHONE:(303)859-5265 DRAWN:KO DATE. CHECKED:DA REV:PERMIT SET 05/09/23 ■ •- F II II H A ■ B ■ C II D E A • B • C ■ D • E • F • G • H 1 m -• giiifir __ ___--Ink . 1 r�,, 21 000 Y-• FOR OFFICIAL USE 2 0041) © // 0 D5 PV-7 MN ■ L 0 1 000000 0 SHEET KEYNOTES 3 RACKING DETAIL (TRANSVERSE) RACKING DETAIL (LONGITUDINAL) 1. ROOF STRUCTURE:P.E.TRUSSES D 1 D2 2. P.E.TRUSSES SIZE:2X4 NOMINAL NOT TO SCALE 3. P.E.TRUSSES SPACING:24"O.C. NOT TO SCALE 4. MAX.P.E.TRUSSES SPAN:NIA 5. ROOF MATERIAL:COMP.SHINGLE 6. ROOF ATTACHMENT TYPE:IRONRIDGE HALO ULTRA 22 20 GRIP I- 7. LAG BOLT DIAMETER:5/16". 8. LAG BOLT EMBEDMENT:3". ■ II r I i I I I I I I I I I I I I I I I I a 9. MAX.HORIZONTAL STANDOFF:48 IN. 22 I I IIIIIIIIIIIIII o 10. MAX.VERTICAL STANDOFF:LANDSCAPE:26 IN., I 1 I 1 I I 1 I I I I I 1 I I I I - PORTRAIT:33 IN. I I I I I 1 I I I I I I I I I I ����������� ���������������� 11. STANDOFF STAGGERING:YES • I III �����������_���������������� 12. RAIL MANUFACTURER(OR EQUIV.):SUNPOWER I I I I I' l = 13. RAIL MODEL(OR EQUIVALENT):INVISIMOUNT MI1 mom 14. RAIL DWEIGHT: UFAC5 TUR R: LF. 4 15. MODULE MANUFACTURER:SUNPOWER O ummt 16. MODULE MODEL:SUNPOWER SPR-X22-360-E-AC 17 I I I I III I I I 10 -_ 17. MODULE LENGTH:61.34" I I "��- 18. MODULE WIDTH:41.18" I I. I I I I „`_"`1r"`__" 19. MODULE WEIGHT:42.9 LBS. I I I I II I I I I I I I I I I I I I I 4 ` Jj,�_ 20. SEE PV-6 FOR CLEARADIMENSNCE: 21. MODULE CLEARANCE:0'-0" III ..a kl.,.._- ,7 4- .....-.-.. I I I I I 1 I 1 I I I k ` ... 22. MODULE MIN.FIRE OFFSET:12"FROM RIDGE,0"I 1 II111111111111 FROM RAKE,EAVE 8 HIP,6"FROM VALLEYS. 23. TOTAL#OF ATTACHMENTS:70 18 24. TOTAL AREA:467 SQ.FT. 25. TOTAL WEIGHT:1201.2 LBS. RACKING DETAIL (TOP) DETAIL (TRANSVERSE) DETAIL (LONGITUDINAL) 6. . 9LB 27. DISTRIBUTED LOAD:2.57 LB PSF. 5 D3 NOT TO SCALE D4 D5 NOT TO SCALE NOT TO SCALE ■ ASSEMBLY DETAILS _ CONTRACTOR EARTHLIGHT TECHNOLOGIES •4 BRYAN COOK RESIDENCE + SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: 812 McCLAINE ST O� A • 6 SILVERTON,OR 97381 ? . / , e a rt h I i a h t 1R 590 SOUTHWEST 87TH AVENUE,SOLAR OR 972240N (28)SUNPOWER SPR-X22-360-E-AC MODULES PHONE:503-874-4142 EXT 159 > 1�ii� �J ASSESSOR'S#:2S111AD00800 PV-3 CONTRACTOR LICENSE:201408 �`rmi SOLAR ANDENERGY SO:_r: 1S PHONE:(303)859-5265 DRAWN:KO DATE: CHECKED:DA REV:PERMIT SET 05/09/23 A • B • C • D • E • F ` G • H A • B ■ C ■ D • E • F • G a H 1 ■ -I FOR OFFICIAL USE 2 GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS. INTERIOR(E)MAR SERVICE EQUIPMENT O 2. ITEMS BELOW MAY NOT BE ON THIS PAGE (E)MAIN PANEL ■ ■ O MODULE BRANCH OO MODULE BRANCH HOUSE O 3 O EXTERIOR ELECTRICAL EQUIPMENT (E)UTILITY METER (N)AC DISCONNECT 0 0 0 O COMBINER(N)AC\ O O O O O O O (N)SUNPOW RMONITORING SYSTEM PVS6 II 11 (N)(1)HOMERUN IN ATTIC A I A ik CA ) A a 4 B B B 1( B�( B B B I BCO \ \ OCOOOOOOOO II ■ ARRAY 1-10.08 kW [x28](N)MODULES / 41.18" TILT:18 DEGREES r� ROOF PITCH:4:12 AZIMUTH:269 DEGREES 5 1— �� MODULE: w ELECTRICALPLAN 61.34 SUNPOWERSPRX22360EA O1 360W Z 118"=1'-0" 0 4' 8' I ■ ■ ELECTRICAL PLAN CONTRACTOR EARTHLIGHT TECHNOLOGIES S��M B RYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: 6 812 McCLAINE ST �r e a rt h I i g h t 14590RESIDENTIAL UTH GRID INTERACTIVE SOLAR D,OR 97224 (28)SUNPOWER SPR-X22-360-E-AC MODULES SILVERTON,OR 97381 s 14590 SOUTHWEST IN TH AVENUE,SOLAR T LLATI P V-4 PHONE:503-874-4142 EXT 159 1Mt ASSESSOR'S#:2S111AD00800 CONTRACTOR LICENSE:201408 4*1�C•� SOLAR N ENERGY SO TONS PHONE:(303)859-5265 DRAWN:KO D CHECKED:DA REV:PERMIT SET 05/09/23 ■ • E • F • G ■ H A • B C D A • B ■ C ■ D ■ E • F • G • H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS TYP. MOD CURRENT-CARRYING OCPD EGC TEMP.CORR. CONDUIT FILL CONT.CURRENT MAX.CURRENT BASE DERATED TERM. LENGTH VOLTS VOLTAGE DROP VOLTAGE ID OTY CONDUCTOR CONDUIT CONDUCTORS IN CONDUIT FACTOR FACTOR AMPS AMPS(125%) AMP. AMP. RATING FEET VOLTS DROP% - 1 - - 1 3 11 12 AWG ENPHASE TRUNK CABLE FREE AIR 2 20A 6 AWG THWN-2,COPPER 0.82 1 14.41A 18.01A 25A 21A 75°C 46.75 240V 1.21 0.61% 11 12 AWG THWN-2, COPPER 6 20A 12 AWG THWN-2,COPPER 0.82 0.8 14.41A 18.01A 25A 16.40A 75°C 30 240V 1.71 0.71% ■ 2 1 11 12 AWG THWN-2, COPPER 3/4"EMT 6 20A 12 AWG THWN-2,COPPER 0.82 0.8 14.41A 18.01A 25A 16.40A 75°C 30 240V 1.71 0.71% ■ 6 12 AWG THWN-2, COPPER 3/4"EMT 6 20A 12 AWG THWN-2,COPPER 0.82 0.8 7.86A 9.83A _25A 16.40A 75°C 30 240V 0.93 0.39% 3 1 28 6 AWG THWN-2, COPPER 3/4"EMT 2 50A 10 AWG THWN-2,COPPER 0.88 1 36.68A 45.85A 65A 57.20A 75°C 5 240V 0.18 0.08% 4 1 28 6 AWG THWN-2, COPPER 3/4"EMT 2 50A 10 AWG THWN-2,COPPER 0.88 1 36.68A 45.85A 65A 57.20A 75°C 20 240V 0.72 0.30% MAX.VD 1.70% FOR OFFICIAL USE 2 SUNPOWER MONITORING SYSTEM PVS6X WITH METERING CT'S RSD COMBINER EATON BRP12B100R 100A,120/240V 1,_:II ______7_ --I , o° ( CB1 ) TO UTILITY ■ I 1/2"EMT,3#14AWG, 1#14G 15A i I FI GRID I (28)SUNPOWER BARE#6 C i I L1 N SPR-X22-360-E-AC O -- - - - 1 12 I ( CB2 ) I I L2 360W c c c 1 1� 20A 11 °°° I I IN BRANCH E. RED 3 BLACF `I 1 I I (E) - UTILITY BARE#6 C °'° METER 1 O - ---- y CB3 ) ° ° y C � 1 1 I 20A (E)GROUNDING 11 :., (N)CT'S ELECTRODE IN BRANCH "'-" _ ....,.; ' BLACF ci L — J ' I r---------II. II BARE#6 C i i 1 L 0 C C ` 1 1 20A I (N)AC ( CB-6 ) N G- 1 BUS BAR °°° i r__( __. DISCONNECT 50A BUS B Ax IN BRANCH _ RED 60A SQUARE D '�7,�—r.�.'--� TO EXISTING - B ncF L _ ; i #DN222RB I + -�- LOADS 1 TO EXISTING I PV SYSTEM EQUIPPED WITH RAPID — - LOADS 4 SHUTDOWN DISCONNECT PER NEC 690.12 (N)SOLADECK i ( CB5 ) I O 4 I N IE) 7N i SYSTEM COMPLIANT WITH NEC 690.13 100A II ••BUS BAR RR i NOTE:NEC 705.12(B)(3):THE SUM OF THE L2- i AMPERE RATINGS OF ALL = I L1 .-1--.. TO EXISTING i OVERCURRENT DEVICES ON i L1 V L2 r al- '- 1 TO EXISTING -�LOADS i PANELBOARDS,BOTH LOAD AND SUPPLY I 1 LOADS H *-- I DEVICES,EXCLUDING THE RATING OF NOTE: DISCONNECT L J THE OVERCURRENT DEVICE ■ II NOTE: BE NO MORE I PROTECTING THE BUSBAR,SHALL NOT THAN 10 FEET FROM THE I (E)MAIN SERVICE PANEL EXCEED THE AMPACITY OF THE BUSBAR. METER I 120/240V, 10, 3W THE RATING OF THE OVERCURRENT SPLIT BUS BAR:200A/200A DEVICE PROTECTING THE BUSBAR I SHALL NOT EXCEED THE RATING OF THE EQUIPMENT LEFT LINE EQUIPMENT RIGHT BUSBAR.SUM OF OVERCURRENT IN (N)NEW UNLESS LINE IS (E)EXISTING PROTECTIVE DEVICES IN UPPER BUSS 5 OTHERWISE NOTED I UNLESS OTHERWISE INCLUDING SOLAR BREAKER DOES NOT NOTED EXCEED 200A OF BUSBAR.OCPD SUM: (E)30A+30A+50A+40A+(N)50A=200A AND DOES NOT EXCEED BUS RATING OF 200A. ■ IILINE DIAGRAM _ CONTRACTOR EARTHLIGHT TECHNOLOGIES •••• B RYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: 812 MRTON,E 9 •>' �: ; e a rt h I i h t RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES 6 SILVERTON,OR 97381 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 PHONE:503-874-4142 EXT 159 ` ay �/� ASSESSOR'S#:2S111AD00800 PV-5 CONTRACTOR LICENSE:201408 �,s==ems SOLAR AN ENERGY SO.uTO\S. PHONE:(303)859-5265 DRAWN:KO DATE: CHECKED:DA REV:PERMIT SET 05/09/23 A • B • C - D • E F • G • H A ■ B • C • D • E • F • G ■ H 1 MODULE AC SPEC AC GROUND OCPD RATED MAX. CURRENT MAX. INPUT CEC VOLTAGE RATING POWER OUTPUT VOLTAGE WEIGHTED CURRENT EFFICIENCY REF. QTY. MAKE AND MODEL FOR OFFICIAL USE 2 PM1-28 28 SUNPOWER SPR-X22-360-E-AC 240V FLOATING 20A 315W 1.31A 15A 79.5V 97.0% DISCONNECTS OCPDS RATED MAX. RATED MAX.VOLTAGE REF. QTY. MAKE AND MODEL CURRENT VOLTAGE REF QTY CURRENT ■ SW1 1 60A SQUARE D#DN222RB 60A 240V CB-1 1 15A 240V CB2-4 3 20A 240V ASHRAE EXTREME LOW -5.4°C,AURORA STATE, OR, USA,45.25N, 122.77W CB-5 1 100A 240V ASHRAE 2% HIGH 32°C,AURORA STATE, OR, USA,45.25N, 122.77W CB-6 1 50A 240V 3 SYSTEM SUMMARY , BRANCH A BRANCH B BRANCH C INVERTERS PER BRANCH 11 11 6 - MAX.AC CURRENT 14.41A 14.41A 7.86A I MAX.AC OUTPUT POWER 3465W 3465W 1890W ARRAY STC POWER 10080W ARRAY PTC POWER 9360.4W MAX.AC CURRENT 45.85A MAX.AC POWER 8820W 4 DERATED (CEC)AC POWER 9777.600W ■ 5 I DESIGN TABLES CONTRACTOR �� BRYAN COOK RESIDENCE SYSTEM AC SIZE @STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: EARTHLIGHT TECHNOLOGIES ♦�► 812 McCLAINE ST •�y'� fr e a rt h I i h t RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES 6 SILVERTON,OR 97381 '5ipt:� 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 PV-6 PHONE:503-874-4142 EXT 159 1�s ASSESSOR'S#:2S111AD00800 DATE: CONTRACTOR LICENSE:201408 +►��r� SOLAR AN:,ENERGY O.uT;OtiS PHONE:(303)859-5265 CHECK KO 05109/23 CHECKED:DA REV:PERMIT SET ■ 1 D • E r F ` G ■ H A ■ B ■ C ■ D ' E • F ■ G ■ H 1 1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE, , INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145,ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. THIS EQUIPMENT FED BY MULTIPLE ■ -■ 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. SOURCES. TOTAL RATING OF ALL 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8"AND PERMANENTLY AFFIXED. OVERCURRENT DEVICES, EXCLUDING 1.5 ALERTING WORDS TO BE COLOR CODED."DANGER"WILL HAVE RED MAIN SUPPLY OVERCURRENT BACKGROUND;"WARNING"WILL HAVE ORANGE BACKGROUND;"CAUTION"WILL HAVE DEVICE, SHALL NOT EXCEED YELLOW BACKGROUND.[ANSI Z535] AMPACITY OF BUSBAR FOR OFFICIAL USE 2 /� �/�� ; LABEL IS LABEL 11 �l V� \� � RAPID SHUTDOYYN INTERCONNECTION NLY REQUIRED S MADE USING THE SUM RULE ELECTRICAL SHOCK HAZARD SWITCH FOR [NEC 705.12 B.3.3]. TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED SOLAR PV SYSTEM STEM DIRECTORY IN THE OPEN POSITION PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE ■ DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING IN 1 LABEL 5 AT EACH DISCONNECTING MEANS FOR MEANS IF NOT IN THE SAME LOCATION(5 3/4"X 1 1/8"). AT RAPID SHUTDOWN DISCONNECT SWITCH [NEC 690.56(B)] PHOTOVOLTAIC EQUIPMENT(2"X 4"). (5 1/4"X 2"). [NEC 690.13]. [NEC 690.56(C)(3)]. WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER,A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV SYSTEM DISCONNECTING MEANS. i\ �\�'' PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN 3 POWER SOURCE BATHROOMS OUTPUT CONNECTION SOLAR PV SYSTEM EQUIPPED [NEC 690.4(D),(E)] DO NOT RELOCATE THIS WITH RAPID SHUTDOWN OVERCURRENT DEVICE PHOTOVOLTAIC POWER SOURCE LABEL 2 TURN RAPID SHUTDOWN ' ■ ■ AT POINT OF INTERCONNECTION SWITCH TO THE"OFF" SOLAR ELECTRIC ! CAU TI 0 N . OVERCURRENT DEVICE(2"X 4"). POSITION TO SHUT A PV PANELS .` LABEL 9 DOWN PV SYSTEM AND [NEC 705.12(B)(2)(3)(B)]. REDUCE SHOCK HAZARD AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING MULTIPLE SOURCES OF POWER IN THE ARRAY . METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE AC DISCONNECT SEPARATED BY ENCLOSURES,WALLS, PARTITIONS,CEILINGS, SAFETY DISCONNECT(S)AS SHOWN: PHOTOVOLTAIC SYSTEM OR FLOORS(5 3/4"X 1 1/8"). LABEL FOR PV SYSTEMS THAT SHUT DOWN THE [NEC 690.31(G)] 4 POWER SOURCE ARRAY AND THE CONDUCTORS LEAVING THE ARRAY. LETTERS AT LEAST 3/8 INCH;WHITE ON RED BACKGROUND; RATED AC THE LABEL SHALL UTILIZE CAPITALIZED CHARACTERS REFLECTIVE OUTPUT CURRENT 3ss6 AMPS [IFC WITH A MINIMUM HEIGHT OF 3/8"IN BLACK ON 605.11.1.1] FRONT NOMINAL OPERATING 240 VOLTS YELLOW BACKGROUND,AND THE REMAINING AC VOLTAGE CHARACTERS SHALL BE CAPITALIZED WITH A dCAUTION MINIMUM HEIGHT OF 3/16"IN BLACK ON WHITE BACKGROUND. LABEL 3 LABEL 6 MULTIPLE SOURCES OF POWER N� MAIN SERVICE PANEL IN ■ AT POINT OF INTERCONNECTION, MARKED AT RAPID SHUTDOWN DEVICE AND MSP El AT DISCONNECTING MEANS(4"X 3"). a 3„X i"). NEC BACK MN (3 [NEC 690.54] 690.56(C)(1)(A) LABEL 10 NM AT UTILITY METER(5 3/4"X 1 1/8') NMIMINIM A A. �_',I v A [NEC 690.56(B)] �.� PHOTOVOLTAIC SYSTEM DUAL POWER SUPPLY �� �i IMUM le mow DISCONNECT SOURCES:UTILITY GRID SOLAR ELECTRIC MUM 5 AND PV SOLAR CIRCUIT BREAKER LABEL 4 ELECTRIC SYSTEM IS BACKFED SOLAR ARRAY UTILITY METER AT EACH AC DISCONNECTING MEANS LABEL 7 LABEL 8 ON ROOFTOP AC DISCONNECT (4"X 1"). AT POINT OF INTERCONNECTION AT POINT OF INTERCONNECTION AC COMBINER PANEL [NEC 690.13(B)]. (2 X 1"). 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 ( X 5/8")' [NEC 705.12(B)(3)] [NEC 705.12(B)(3)] IN ■ ° PLACARDS & LABELS I CONTRACTOR EARTHLIGHT TECHNOLOGIES �.et . B RYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: 812 McCLAINE ST £` 4- earth I i g h t RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES p 6 SILVERTON,OR 97381 �f 14590 SOUTHWEST 87TH AVENUE,TIGARD.OR 97224 f U'7 PHONE:503-874-4142 EXT 159 �,�� ASSESSOR'S#:2S111AD00800 DATE: „�►ii/ SOLAR P ENERGY SO „tiS ONE:(303)859-5265 DRAWN:KO CONTRACTOR LICENSE:201408 �� PH 05/09/23 CHECKED:DA REV:PERMIT SET • E •- F ■ G • H A IN B •- C D A w B . C m D m E i• F w G w H 1 X-Series:X22-370 I X22-360 Sti' Fower-Reasicent,.: AC Mocule 0 t t••I r,l_ SUNPOWER'' inverter Model Type F 0Q 7XS) @240 VAC Ai 0 , X-Series: X22-370 I X22-360 Ill '......,'R Residential SunPower® .. , . ,,. 2 AC IVoc ule FOR OFFICIAL USE .,, . , . Built specifically for use with the SunPower Equinox system,the only fully integrated solution designed,engineered,and warranted by one manufacturer. , Maximum Power.Minimalist Design. 'NMI :1..,T', ,-.:.,:",'IF P'':C..4-'"W', '-'€-,.a•-.5 rno•f 0 a-- d'0'3-70',7<, /MS 0 Arajr— pe• -i c.:' C:-.I.,9:C I.%.:'fE,7,67,"000 d,,,6,, ec.;L:r-,--c-, SPR-X22 370-E-AC SPR-X22 360-E-AC (71 Highest Lifetime Energy and Savings. .,,, .. • ...- I .i( F,.:', (., .ie.! ,,?' 601,,rgore eney, nye, 25 yrro-,,,,, 3 , 'ed,6\7:01c,000,„60.707. 4,0 no'r-a'ahaOn 30,7°:+i-,,r,temttE•31,,r',S 3 Fundamentally Different. .. . w a - is And Better. 2 SunPower X-Series Up to 60% more - 2 -4,-,..,,,,-,v ,..--,,, ., lifetime *f tk-k-,4,:if.10,‘4-44. --,*-4'--- energy IN ,h V . or,°•-:;.442.....'14.:S, .....,4W;46:4,1*Iiildte-CM, i7 r., The SunPower Maxeon'Solar Cell Years of operation . F-.at,E.,...rw.,es,cf,..:.,--.,v 22- ' —Ddr,c-sa‘,adan,E 4 . ,..,,,,T,dtcr•er,,k-...3;),'[., Best Reliability.Best Warranty. • ,,,-711Pr'eo t,of,ti,-,era. 'o.,-,:,cf,c,. o,:-,13 ,---_,,-"F_ v,t,,, ,.., utr-vents.0'ea,<,,,ge onc,,,-yrort:on VOtr: -no'e than 25 91,1lior 010dUieS deployeO around — • ' Me world SJ0Powe'technology s prover to Iasi Hats t,' i',', ,A,Th v.ie stana oehnd Our madole and n•Pcroinverter ...., I: I it"toe the,noastry's;test 25-year Combined Pow°,and Ilk r-n()duct Warranty.ingludIng the highest power vy,,,,ra-Ty• ,_ * - • X , ir.soidr 1 • II?. ..--:,... 412,1 (1,10, o Factory-integrated Microinverter 0. - , . , i 1 o . . ,,,,,ii, o) WO-z.,0. — $076077t17,,,,,, l ) = ,..ittiftrty,.0yrty..,,,„ , I ',-'2•;_. ',-...•:c,,- .° ,g4t*,-,0,..rfS.,--,,14:1,,,,,„ SunPower' 12% , • ' -'4,..,„Z. ,,,4,,,t' i,„,1te,,,,,,,,,,,,,,_ E-Series and X-Series more 026 '"o,,,, ,,,,,.„f. .,., , ., '' ',. , , - ,. Arj,,f4,,":4‹ ,- power 5 ; . in year t C":':'`''''' Y',:','‘:::,' ''''' '', .,:,','"'''t:''.'',',' LISTED SUNPOWERF. Modo.hrc Pri .,tyw Years of operation Datasheet sunpower.com . 0 CONTRACTOR RESOURCE SHEET EARTHLIGHT TECHNOLOGIES •,...44. B RYAN COOK RESIDENCE 812 McCLAINE ST -.44 4 • . 4- ...0 - SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION 6 SILVERTON,OR 97381 4441.'11/ e a rt h I i g ht 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 (28)SUNPOWER SPR-X22-360-E-AC MODULES PHONE:503-874-4142 EXT 159 At illissm ASSESSOR'S#:2S111AD00800 PV-8 CONTRACTOR LICENSE:201408 ,lireriff.' 41,41...., SOLAR AN: ENERGY SOOT ON.S PHONE:(303)859-5265 DRAWN:KO DATE: CHECKED:DA REV:PERMIT SET 05/09/23 A N B • C 1•1 D 1•1 E • F or G I. H A • B m C • D • E • F • G le H 1 , ‘ .-10. - '''''• '' 4, • .4,- -- .—, . :..,. ..„,. ,.., . ,„.,. ._.. . -AP. 1 1 . . . ,,..- •1 SunPower'i EnergyLinkTm I Residential and Commercial PVS6 -• . . . '-.'iz,,,-t-y,:te.:.:.„.,v,,,F:!:,'ic,,,..,4A:,;I.,,,.....,...,,''.,''''[,'.::.'.:.-,: -..'.. . .... • A,. SunPower Monitoring Websites PVS6 SunPower AC Modules SunPower® EnergyLinkim I Residential and Commercial PVS6 - Improve Support, 1111 ) FOR OFFICIAL USE 2 Reduce Maintenance Costs SonPower EnergyLink----Plug•and-Play Installation 1,1, ,....,,itIliiiitliiiii ...40pagammiam mumiiim00- Ak,,,,-,tul.,,,e mo-,,oHng 33ees,te esatmes you rcy , • f,eff-a-:,.5.-Li me:JD of 3.*.smumor sqes ' ...... .u. ., t,,,..'*:,motely manage hurm.Vectr-Of ft.,,tes • Receive.elect,,,m syster reports Illialdib;:-',7•* .- Multiple communication options include Ethernet,Wi-Fi,and cellular. • Locate s,,,esrem,,,,,m..r.,•,,1 reri,otery diagnose, 0 • . . • Da-geese efr,,,m,omm,e • Drill cfloon.for Me Sti.g.uS Of rdiv'dua,fieffiC es . ..-,,..,,,,,,b:E g.,ce,-.•:,:umf,c.,,-,of demr-er.,r-J...,3,1;,estehm3.tr, esete,',-,K: Site Requirements Operating Conditions ......,.. ...... .. ,..„.„ .............._• ,....,.... _ • Re,..rerle:er'a.le;-..g(i);_;Cr!Or,rc,ee,'',8 r-) r ,-,'3) a W11111011 . . . .., . 3 . .7....ekncy.e d!agkok6,:k Of Pvse,ar,„1,,,,e,-le--s .':'-'77.:::,--if; ' rf-es:y s3egramur,vf.,:f3t,SJ-Powe, re,3sf:3S Communication . . . .. . • Mechanical — i Add Value for Customers 1. ..,_ Robust Cloud Connectivity vvi[k,the SunPower Monitoring System, MU!!tp,e Otrtr'.)nrS i.0 rna,n,,a!r,opt om33 !f: customers c..am ,,,,, , . * 3 courleetivity• ;OE bar b'''iiiih'iiiv'iii-: • See whar tneir soar systerr orcidwies each day,month:,or year :4,, r ,-,' irr,egt4rA,,,,.A.,,,,efnjr • H.i lloil r 61,0 ET he,r)er ' ''''''''' ' ''' '''' -1, • Optimize their soiar investment and save on • Wiics Web and Mobile Device Support ri''.... iii•tiiagic ,E'f. ,,:filf. t 4 I ":-.,-s: e-Srte 2aQ.nila r'.'r.,.':frr.11-.:;i.ti-ri' 4 energy expenses i. • ceisiia:-bachub i • See their energy use and estimated bill savings F m kr t6', '?1,..,me. • See their scar systems performance using the mouii •.3e-,df: i ary3 ,, ,c..,' SunPower monitoring website or moble i app e ces .P.-,,,t, Pac' I o,o Cifs'ih-"iriei aisir-i i iii,--eate a,:C'..-,...,-17 O'r,',E'r r.','.:aicgaz,-,-Ls.5.,..e.2i,lav-,:eLQ.:ifr Warranty and Certifications •1 apt.titt, "\rA.NE 4.:'...,,....)'e „, ,-,C,C:gi€,..-3,- ,,,,,:ye 'EIII e r --, -..,-,,_ • s:n MID FCC ID:YAW529027 E503346 •IlIk.--011111111111111111=. ..? ' — ' 5:30'33C,RevC I . .....,..„ ; . -i.2,:i1,,..o ooPowe,_,o,,,t on.,-Ji,go,.,seo.,..'.'.1,NPL7,,,h-R Sr-NPOWE''-':rt-,gc ace EN Er FStl!"NK are tra0..ma o,a,,eg,ste,o0 „-. 2,3,1-4,0Ors of 5, Ftw.er Thr.0-at on i .IPOooe 6,:.•Poe ere rep FA.E.-ec,z,..,e,sa o,o‘Aopi.Inc AkooroiO a od:koog le Play 2,,e735.-,,,,,, SUNP - WER® 5 _ cr.oge wIthootnotce SUNP WER® I , CONTRACTOR RESOURCE SHEET EARTHLIGHT TECHNOLOGIES 4,4440 BRYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: ..* 6 812 McCLAINE ST , 4P-* RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES SILVERTON,OR 97381 -:'4 earthlight 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 PV-9 PHONE:503-874-4142 EXT 159 '' 4f.4111/00 'As arittrilr, ASSESSOR'S#:2S111AD00800 CONTRACTOR LICENSE:201408 4,orararie 'Warm.," SOLAR ANL,ENERGY SOLigiONS PHONE:(303)859-5265 DRAWN:KO DATE: CHECKED:DA REV:PERMIT SET 05/09/23 A • B • C • D • E • F 11 G • H A a B .. C mi D . E .. F • G NI H ',..,r4.'4;•'-'-:'-''' , •-'-':.;%„*.r,:z...-.:-.,.!,i.,:-[.-.. •,.:--:-iL.--::..-..,„tAz-:::: -.:7--....i.:.: .•,.:',.. .-',:::::..'4.-..-i-.0--;:..A,,-.4: :: ::..:-.!,'..Agr,,:.`,.-;,.:,;,-f- ',: -c.-.......ge,1,. .„..--,,-,..---:-.,..:::,....:-..-:..:-.-,...,::::„.•,:-..g,•,,.,,.„.1,-,,,...,5,.,.,2,...-i,...:?,-!.,,,t,,A.4.1,- ;,.,„1„,,g.,-,,Ajestii,i0.544-.Ei-,-,e.z..-.,:-A::,',,..a.:.,.ei,l-R:....;,.:E..w.::.,...,:,. .--,;,..2..4...:,:::,, ,,v,...:,t-,-,--.:•,:.:-..:',*,•;,;:,;;„,,,I.14,41,0". • .- . _...--•-- , ,... „;..-,,..1.-,!!..vvt ,....-..:;:,.,;,---.: ,:-:-..:o:-..,g-if5-mgs -i:-:.;-:,-,,i..t:,:.:-...,:;...::t;:,g,i:.c.-nicri*.aso .----',-*.;04. ::••if.,„.: . -,„..,.,..7 '. '.•,--1 .....----.:7.- '. . ...!.-"••:-pii..kiix:„t:....,:.,,--.A,.:.-,,,-•:-.,..i.&,,.i.k.,::,:ig..i.witzA.4.-zo4.4.40:;0--,AF:';!.:-:.-.1g;Fc;-'.-.W-44.:,:ix,..:-,.',T:"... ,v;tf.s-::,-‘.4-.:441-;14tifos•44141.4g.iii,iA,„,,.,';, ;,•7:'',.',.',:!,,>,-_,,,,..,--- ,• .. ,. 000-41k-vim. .244;.t-ii,..-:.4.M.:Ati,e5ciEst.„-;:i;kesAtoge.#4.441.°,-„.3,.,,; :kv.:,,g 7,.„.-.4,..,., .'..,,•;t,.,„..-:. ••.•,-,-.,,,„. ..„.. - , ''.7...A.'4kf0;:. ,,,,f.-'..,,4,..-.:;it.i.....,,,, . 0,,.7.41.-..Zielii'-4-;Aaiii*,‘'at,--0401r10.;.•11041,WW,",-;:t.iikW.-?-..-.1fiJ.44:.•'.';f...- --rq.:44001,44r" -7:'-n,W.P.Ot.',-.,,:--'- ...r :,, fii-;.*-:. , .. :.'1.--...:".•7.,•; .-;Ito4.,.4r-PAVS14.44031iitl'- '.'t-:%-0a4c.i.'.*.i.a;:P-et,. :••',X. .:',:cr,,%,:c!;.,:,'1.',„4i':1.-A..w.,'; ..- -,..,-':4'.',a4L....-On.‹:'''','!"'•-- ,..-:,,,,,,:in,...,:;,,,,,-,:f:owygtrzlio*,,ze.v:::..4:-,-..A.1:4„.:051,v1,„„ ,,,,,,:„,?,.:„.y-,.„.:,,,,: ,,, q...1;w6.-4..A....,-A.A.i.a.,,.74-4,,,,.„_.4,,,..„...,,,,„...,,,-..-.-:-...,,----,- ',-- - ..-- ,-',r-•-''AV'''''''''-,f,'''"E• ':'-4. ."''',,,-'7-',.;41-44•Vm'42r.Z•14:4-•,'n,:.-P-4.T-!:PY...'0`,..',.!..2.''.'-'- --''', '','',.,-,'.E-1'.'..,....'::: :,7-?:.!!,,,i31,1,-.t!i:117.T.,..''3'-''',-;;;;;.-------- L,' . • ..-..,,f-.. -•:,-"':::...z:..-gw..,: c,,,,,-. -.3,,;;:mt.i.3,7,-,tf„.e.,:--..,. .:1,,,,,,,v.,,T.z,..1",.',c.,.::,,. ., ,,-,:::::.,,,,,::,-' • - ":.:,"":',4-N;17.'T.-,,::....,,!.:.-,: .1,...7. 1,,ti-',,,,,-...",,..; . .. ' . .. ..,, .,„. ,,_.,. ,,. . .4egifilEr' ' '''''' -'''t:'.',!:''',,',.....,''' . oi.•., .'44,'''''''':*".• . .-• ,.'. 7,.... „.........„. ,,,,, _____ .__..... . ,.•..,, ..._ , SunPower'''. InvisiMountTm Residential Mounting System SunPower InvisiMountTM Residential Mounting System Simple and Fast Installation InvisiMount Component Images FOR OFFICIAL USE 2 d • meted moduletio-rail grounding . • Pre assembied,Tild and end ciamps • Levitating mid clartip tor easy placement . , ..u.i.i.. , . . • Mid ctamp%Nairn faiailtates even . . .. . 1 - ..,.........., _,...., . . . ..... , , - i. : .-...„.. . -......... . „....... ... • `.-,imple.ore-driiied rail splice .. . M • tit 2703 L:steo integrated grounding ...,,,,,......,,...„.„,,, . . . , h i.u.. ... i ; . .. ,....... ,„........., Flexible Design ,i,-• ...._ . . . ,.„ iliikiiii.i.4::.,-Ii.:=.4R.iii.x.,0;i9. „..,i ,.,:,;,;,,...,,,...„iii:ipi,,•,..i.ii:i,iiiiii..,i, , .. ,•$ - • Addresses nearly all sloped residential roots •.•,' • Design in ands op and portrait •• Hails enabl e easy obstacle management c* Customer-Preferred Aesthetics . ... . ..,.. . • ,,......„, ,,s,,,, • #1 module and-rt'I mounting aesthetics iiA 011illftwomilimi-w ..0. • Best-in-class system aesthetics Elegant Simplicity • Premium,low protite design SunPo\iver" inyisiMountw• is a SunPower-designed • InvisiMount Component Details InvisiMount Operating Conditions • Black anodized components II • Hidden mid ciamps and end ciamps rail-based mounting system.The invisiMount system i.,..,..i hardvvare.and capped,flush rails -- - - ' - - -- • --- -- addresses residential sloped roofs and combines faster • - InvisiMount Warranties And Certifications ' Part of Superior System installation time,design flexibility,and superior aesthetics. .-i.., , • .i.....i•ii, , • Built for USE with SunPower DC and AC modules The InvisiMount product was specifically envisioned and • Best-in-class system reliability and aesthetics 4 • Combine with SunPower modules and engineered to pair with SunPower modules.The resulting monitoring app system-revel approach will amplify the aesthetic and Roof Attachment Hardware Supported by installation benefits for both homeowners and installers. InvisiMount System Design Tool Roof Attachment Hardware Warranties ir, 0 sunpower.com .A,,,,i,,,4,-,,-- ,,,..„. ,,..,. -• fr.>, (0) ., .. ..,...,,,.. . ,. .,.„...„.,..,,,,.,„. .. ... . ..,, .. ... ., ..,,.. „.. . „ ,... .. . ...,. „.. . „ , „......,. , 5 S U N P- , WE R S U N P :. -WER I RESOURCE SHEET CONTRACTOR EARTHLIGHT TECHNOLOGIES ..4.4, BRYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: ..(4', 6 812 McCLAINE ST RESIDENTIAL GRID INTERACTIVE SOLAR INSTALLATION (28)SUNPOWER SPR-X22-360-E-AC MODULES SILVERTON,OR 97381 -4- -A • - .40•4.-iiii e a rt hlig ht 14590 SOUTHWEST 87TH AVENUE,TIGARD,OR 97224 PV-1 0 ' PHONE:503-874-4142 EXT 159 -iRo„atiffiR*1 ASSESSOR'S#:2S111AD00800 CONTRACTOR LICENSE:201408 ftysiwArof' -101,.......... SOLAR AN ENERGY SOWMONS PHONE:(303)859-5265 DRAWN:KO DATE: CHECKED:DA REV:PERMIT SET 05/09/23 A I. B .1- C 1. D II E .. F . G 1. H . , A IIB ■ C ■ D ■ E ■ F ■ G ■ H Cut Sheet Cut Sheet 1 IRONRIDGE QuickMount Halo UltraGrip 1. Halo UltraGrip .38 FOR OFFICIAL USE 2 ,._1/4. 3.35 `,. —RD STRUCTURAL SCREW PN RD-1430-01-M1 SOLD SEPARATELY ''. 0 _ SHOWN FOR REFERENCE it 1l Release Liner . rim shown for reference 4 P Jr'r 3.83 - 3 111,04 ll p• /1 40 ___ __�1 `seri I / 0.26 / \ ' • 0 I in 1.56 111111111 101 iii=111•�1 111111111 ITEM NO DESCRIPTION I QTY IN KIT ' ice`\ s 11 4 •1 QM Halo UltraGrip(Miil or Black) I I 0 , k 0 1 34 *ir -. . \ i 1 PART NUMBER DESCRIPTION } I l ■ QM-HUG-01-M1 Halo UltraGrip-Mill QM-HUG-01-B1 Halo UltraGrip-Black 2.99 1 Property Value Material 3000 Series Aluminium 5 Q Finish i Mill or Black i QM-HUG-01-81 or QM-HUG-01-M1 Cut Sheet Rev 1.0 c 2022 IronRidge,Inc.All rights reserved.Visit www.ir-patenis.tom for patent information. OM-HUG-01-B1 or QM-HUG-01-Mt Cut Sheet Rev 1.0 ©20221ronRidge,Inc Alt nghis reserved.Vier xww.ir-patents-can for patent information. 1.■ RESOURCE SHEET CONTRACTOR �� BRYAN COOK RESIDENCE SYSTEM AC SIZE @ STC:8.820 kW SYSTEM DC SIZE @ STC:10.080 kW PAGE: EARTHLIGHT TECHNOLOGIES 812 MCCLAINE ST �1. 8/=�/, e a rt h I i g h t ASSESSOR'S#:2S11. ' RESIDENTIAL GRID 11AD OSOON ETERACTIVE STOIGARD.OR g7LAR 22 ON (28)SUNPOWER SPR-X22-360-E-AC MODULES PV-11 6 SILVERTON,OR 97381 T SOUTHWEST 87TH PHONE:503-874-4142 EXT 159 ,,4 1�a/ DATE: CONTRACTOR LICENSE:201408 +����� SOLAR arv:-ENERGY SOLUTIONS PHONE:(303)859-5265 CHECK KO 05/09/23 CHECKED:DA REV:PERMIT SET A ■ B • C I D or E - F ■ G ■ H