Plans •GENERAL NOTES AERIAL VIEW CODE AND STANDARDS r ,. 1.ALL WORK SHALL COMPLY WITH 2017 OREGON ELECTRIC SPECIALTY CODE(OESC),2019 OREGON � � AV EN STRUCTURAL SPECIALTY CODE,2017 OREGON RESIDENTIAL SPECIALTY CODE,AND ALL STATE AND LOCAL BUILDING AND ELECTRICAL CODES. + f I 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. 4 s.' 1403 N. Research Way } anZ SITE NOTES/OSHA REGULATION SW ;11 I)Z a Cl I OF ('j 1T 84097 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. I' p, {}�A a'-:s s i.4480 # ��`WWW.��� '�+'�NSOLAR.COM 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. e d *4 "" CONFIDENTIAL THE INFORMATION 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND gr , , HEREIN CONTAINED SHALL NOT BE THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT . ' USED FOR THE BENEFIT OF ANYONE 0 : EXCEPT BLUE RAVEN SOLAR NOR THE BUILDING OR STRUCTURE. OFFICE V � SHALL IT BE DISCLOSED IN WHOLE OR SOLAR CONTRACTOR COPY < IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. CONNECTION ORGANIZATION, SALE AND 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER --,4 ..,. USE OF NEC ION WITH THE EQUIPMENT, AND THE MANUFACTURER'S INSTALLATION REQUIREMENTS. --,, *.,,^.: s e WITHOUT THE WRITTEN PERMISSION 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF OF BLUE RAVEN SOLAR LLC. STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO ,..s ' .mob ::, s LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. --- � ��*� N A BC El-- ) 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. s� � `. 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. -, , CERTIFIED 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. # 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT d A ' PV INSTALLATION AVAILABLE. 1 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC PROFESSIONAL PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND ,,SScott Gurney CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND #PV-011719-015866 LISTED FOR THE APPLICATION PER NEC 690.4(B). r, 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. • gre . 44 CONTRACTOR: 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) BRS FIELD OPS IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. 1 800FIE7480 EQUIPMENT LOCATIONS 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT , ` WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS - ` SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). �. ,� Ct'l 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC �, a Z ao APPLICABLE CODES. .. 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. y.. sad _ ,2.5 is s ;#fi,riligi O CITY OF TTC _ J) wr CA co• co PROJECT INFORMATION. „ co °' I € �xl?�;'I D FGI CODE COMPLIANCE # CC,;f C N N NUMBER OF STORIES: 1 n;< ,roN cd: [V I N N "1 O � CONDUIT RUN: Interior [ Z e . c N N 0:: : ECOBEE QTY: 1 ' mg 2 O LIGHT BULB QTY: 18 1 #: M.S1Zo23 '�t 1 Z- Si �' W W Permit ,�+. W �� O PV METER: Not Required 2t,},� l 'ESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX iar�� .. a) ILI II•I 1`�. :sfis SW - cn0 NN t1�3 ROOF TYPE(1)INFORMATION :. #: WIND SPEED: 100 mph CONSTRUCTION -V-B PV1 -COVER SHEET A prOVec inhr '� O N ROOF TYPE:Comp Shingle ylZ ?� GROUND SNOW LOAD:40 Ib/ft2 ZONING: RESIDENTIAL PV2 -SITE PLAN 31 be on ,,�'... _C N es FRAMING TYPE: Manuf6tured Truss Date: ( PV3 ROOF PLAN D 'U a) cm V V WIND EXPOSURE FACTOR:C 0 7- H Q G SHEATHING TYPE: SKIP SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL 1 ATTACHMENT: SFM Infinity Flashkit PV5- ELECTRICAL 3-LINE DIAGRAM RACKING: Unirac SFM Infinity @ 48"OC Portrait/48"OC Landscape DRAWING BY: SCOPE OF WORK PV6- ELECTRICAL CALCULATIONS NUMBER OF ATTACHMENTS: 78 PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore ROOF TYPE(2)INFORMATION (IF APPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHER SHEETS AS REQUIRED) SS- PRODUCT SPEC. SHEETS PLOT DATE: *SEE PV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. April 13, 2023 PROJECT NUMBER: SYSTEM TO BE INSTALLED INFORMATION: ACIDITY OF PERMIT UTILITY COMPANY: THE ISSUANCE OF A PERMIT Portland General Electric (PGE) 735175 BASED ON CONSTRUCTION . L=r ,, DC SYSTEM SIZE: 12.8 kW DC SHEET NAME: AC SYSTEM SIZE: 9.28 kW AC DOCUMENTS AND OTHER �'"4� , 1 r MODULE TYPE: (32)QCeIIs Q.PEAK DUO BLK ML-G10+400 DATA SHALL NOT PREVENT r\, PERMIT ISSUER: COVER SHEET INVERTER TYPE: Enphase IQ8PLUS-72-2-US THE CODE OFFICIAL FROM Cityof Tigard Y'11.:1.C L REVISION: PAGE NUMBER: MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 'SQUIRING THE CORRECT ON g 0 p"1 1 OF ERRORS. ORSC 105.4 r V FRONT OF HOME LEGEND PV SYSTEM SPECIFICATIONS 11820 SW MANZANITA ST TOTAL NUMBER OF MODULES: 32 MODULE MAKE AND MODEL: QCells Q.PEAK DUO BLK ML-G10+400 JUNCTION BOX MODULE WATTAGE: 400W DC " " rMl UTILITY METER INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US J 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) MSP MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC 800.377.4480 INVERTER NOMINAL VOLTAGE:240V AC AC DISCONNECT WWW.BLUERAVENSOLAR.COM INVERTER WATTAGE: 290W AC CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE CB COMBINER BOX USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR LOAD CENTER IN PART TO OTHERS OUTSIDE LC RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, SUB SUBPANEL WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. A r(19) \ / PV PV METER rMTh J RIABCEP AC TS TRANSFER SWITCH CERTIFIED CB PV INSTALLATION ---1ESS SUNPOWER ESS PROFESSIONAL MSPII • B B Scott Gumey #PV-011719-015866 B B HUB SUNPOWER HUB+ CONTRACTOR: is B RPO REMOTE POWER OFF BRS HELD OPS 800-377-4480 FIRE SETBACK o B B ❑ j TRENCHING 0 0 //////////////////////////////i //////////////////// //id/7/f II Z < 0 B B PROPERTY LINE • ® ® ® ® ® ® I H _ Y - SCALE: 3/32" = 1'-0" Q cn N c‘i ® ® M ® ® ® \ 1 2 as N O) r L/ o ° ® ® ® ® ® LL -o N 0)ci N N ° ® ® ® ® ® Z N C N (1) Ix -Eh ga 22 2 —I � - ILI I— � CO -C N CON N D .2 _0 I. 00 V TI— QG DRAWING BY: Brendan Fillmore PLOT DATE: April 13, 2023 PROJECT NUMBER: 1.AC DISCONNECT TO BE LOCATED WITHIN 10 FT. OF METER. , j 735175♦ 2. FOR PRESCRIPTIVE INSTALLATIONS, ROOF ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24 IN. OC IN ANY DIRECTION WHERE LOCATED SHEET NAME: WITHIN 3 FT. OF A ROOF EDGE, HIP, EAVE, OR RIDGE (OSSC 3111.3.5.3) 3. FOR NON-PRESCRIPTIVE INSTALLATIONS, PLANS WILL BE APPROVED I I SITE PLAN AND STAMPED BY LICENCED ENGINEER AND ALL ATTACHMENT SPACING -, — . J REVISION: PAGE NUMBER. WILL BE AS SHOWN ON PV4. 0 PV2 , LEGEND PV SYSTEM SPECIFICATIONS TOTAL NUMBER OF MODULES: 32 JUNCTION BOX MODULE MAKE AND MODEL: ells Q.PEAK DUO BLK ML-G10+400 RAVEN N MODULE WATTAGE: 400W DC �MJ UTILITY METER INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) MSP MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC FRONT OF HOME WWW.BLUERA 800.377.4480 7.4480 R.COM INVERTER NOMINAL VOLTAGE: 240V AC AC DISCONNECT INVERTER WATTAGE:290W AC UNDERGROUND SERVICE LINE - CONFIDENTIAL-THE INFORMATIONHEREIN CONTAINED SHALL NOT BE CB COMBINER BOX USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR A LOAD CENTER IN PART TO OTHERS OUTSIDE LC RECIPIENTS ORGANIZATION,EXCEPT 1St \ /82B IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, SUB SUBPANELWITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC. POINT OF INTERCONNECTION �J PV METER NABCEP �MSP� / TS TRANSFER SWITCH CERTIFIED _� y 1' //,F_ PV INSTALLATION y y; ESS SUNPOWER ESS PROFESSIONAL Scott Gurney #PV-011719-015866 HUB SUNPOWER HUB+ CONTRACTOR: // S y BRS HELD OPS / #OF RPO REMOTE POWER OFF / 800-377-4480 #OF MODULES: 10 AZIMUTH: 90 j FIRE SETBACK / IZ S PITCH: 27 o AREA:468 ft.2/ TSRF:76% ' I �, / / TRENCHING U U 1, Qo /////////////////////////////////////////////////////(////d////i i I _ N yco co • SCALE: 1/8" = 1'-0" a (A ,i yA #t #4 vt #;1 ® 2 alN oi 0 ,..„ � iEo P4o iit el! i� 0t it iACC N N Z � LU � N f W o u, eti O aW O U) V 7 H < G MP1 #OF MODULES:22 DRAWING BY: AZIMUTH: 180 Brendan Fillmore PITCH: 27 TSRF: 80% PLOT DATE: AREA:940 ft.2 April 13, 2023 PROJECT NUMBER: 1.AC DISCONNECT TO BE LOCATED WITHIN 10 FT. OF METER. 735175 2. FOR PRESCRIPTIVE INSTALLATIONS, ROOF ATTACHMENTS SHALL BE SHEET NAME: SPACED NO GREATER THAN 24 IN. OC IN ANY DIRECTION WHERE LOCATED WITHIN 3 FT. OF A ROOF EDGE, HIP, EAVE,OR RIDGE (OSSC 3111.3.5.3) ROOF PLAN 3. FOR NON-PRESCRIPTIVE INSTALLATIONS, PLANS WILL BE APPROVED AND STAMPED BY LICENCED ENGINEER AND ALL ATTACHMENT SPACING REVISION: PAGE NUMBER: WILL BE AS SHOWN ON PV4. 0 PV3 • STRUCTURAL INFORMATION: STRUCTURAL NOTES: PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5"SPLICE ROOF TYPE(1): ROOF TYPE: Comp Shingle 1.AC DISCONNECT TO BE LOCATED WITHIN 10 FT. OF METER. I SHEATHING TYPE: SKIP 2. FOR PRESCRIPTIVE INSTALLATIONS, ROOF ATTACHMENTS :_ — FRAMING TYPE: Manufactured Truss SHALL BE SPACED NO GREATER THAN 24 IN.OC IN ANY FRAMING SIZE:2x4 @ 24"OC DIRECTION WHERE LOCATED WITHIN 3 FT. OF A ROOF EDGE, IX CEILING JOIST SIZE:2x4 a 24"OC HIP, EAVE, OR RIDGE(OSSC 3111.3.5.3) 23„ "I III 1403 N. Research Way 3. FOR NON-PRESCRIPTIVE INSTALLATIONS, PLANS WILL BE y MAX. r 48" MAX. LANDSCAPE Orem, UT 84097 ATTACHMENT: SFM Infinity Flashkit APPROVED AND STAMPED BY LICENCED ENGINEER AND ALL 800.377.4480 RACKING: Unirac SFM Infinity ATTACHMENT SPACING WILL BE AS SHOWN ON PV4. WWW.BLUERAVENSOLAR.COM 48"OC Portrait/48"OC Landscape PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5"SPLICE CONFIDENTIAL-THE INFORMATION BER OF ATTACHMENTS: 78 None HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE PV MODULE COUNT: 32 Modules _ I I,;. SHALL BE DISC RAVEN IN SOLAR o NOR IN PART TO OTHERS OUTSIDE TOTAL ARRAY AREA: 652.8 ft2(20.4ft2/panel) RECIPIENTS ORGANIZATION,EXCEPT TOTAL ROOF AREA:2753 ft2 IN CONNECTION WITH THE SALE AND ARRAY/ROOF AREA:23.7% V I I) V " USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION ARRAY WEIGHT: 1,600 lbs(50 lbs/panel) -__ 23" 1 1 OF BLUE RAVEN SOLAR LLC. 48" Max. PORTRAIT DISTRIBUTED LOAD:2.45 lbs/ft2 MAX. POINT LOAD: 20.51 lbs/attachment *NOTE LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY ATTACHMENT SPACING- FRONT VIEW BASED ON FIELD CONDITIONS.MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER ENGINEER OF RECORD SPECIFICATIONS O -RACKING ATTACHMENTS TO BE STAGGERED NABCEP . SCALE: 3/4"= 1'-0" CERTIFIED UNIRAC SFM INFINITY UNIRAC SFM MICRORAIL/SPLICE PV INSTALLATION PV MODULE w� PROFESSIONAL wiiir QCELLS Q.PEAK DUO BLK ML-G10+400 r A . -..--- Scott Gurney O #PV-011719-015866 PV MODULE �_ � PORTRAIT CONTRACTOR: lEOV UNIRAC SFM SLIDER / , - BRS FIELD OPS ' ROOF STRUCTURE 800-377-4480 (E) ROOF —_--- MODULE r0) SHEATHING - WIDTH co FLASHING v— (1)5/16" STAINLESS STEEL LAG BOLT 1/���/ / -� .la •• < 0 2/z MIN. EMBED. =' LANDSCAPE OO WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 'V „ 270 �c Y co t�� MODULE I a (A N • e —� jc�— WIDTH c� co rn N _�' C N w w A MIDDLE/TOP STANDOFF DETAIL ATTACHMENT SPACING- SIDE VIEW LL N N N (E) BUILDING STRUCTURE D Z 2 2 c co N SCALE: 3"= 1'-0" SCALE: 1/2"= 1'-0" CC Th a 2 2 QCELLS Q.PEAK DUO BLK ML-G10+400 J PV MODULE O (/) O CI) U N .CN N � In MC) CO 00 UNIRAC SFM TRIMRAIL Di FLASHING DRAWING BY: UNIRAC SFM SLIDER AND Brendan Fillmore TRIMRAIL ROOF ATTACHMENT - (E) ROOF PLOT DATE SHEATHING April 13, 2023 (1)5/16"STAINLESS STEEL LAG BOLT /// 1_/L1///1Z//(// // PROJECT NUMBER. WITH 2-1/2" MIN. EMBEDMENT 735175 AND FLAT WASHER a" MIN. EMBED. SHEET NAME: 9 STRUCTURAL BOTTOM STANDOFF DETAIL REVISION PAGE NUMBER: B (E) BUILDING STRUCTURE 0 PV4 SCALE: 3"= 1'-0" 3 A AC (1) 6 AWG T111NN/THWN-2.CU.,BLACK 111) 36.7 A AC 13) 10 AWG THHN/THW$-2,C L BLACK#11) MAX 13,3 A AC (1) 10 AWG T11HN/THWN- Cl).,B.ACK(11) MAX 13,3 A AC (1) 12=2 TC-ER,TINNNTINWN-Z CU. MAX 13 V AC l5 (11 6 AW.THHN/rHWN-2 CU„RED(12) 240 V AC (31 10 AWGTHHN/THWN-2,CU-,RED(1.21 240 V AC 2 (1) 10 AWGTNHN/THWN.2,CU„RED 1121 240 V AC 1 (1) 6 AWG BARE.CU(EGC) (1) 6 AWG THHN/THWN-2,CU„WHITE(N) (11 10 AW GTHHN/THWN-2,Cl),. GREEN(MCI (1) 10 AWG THHN/fi11WN-2,CIL GREEN(EGC) \le' (1) 10 AWG THHN/THWN-2.CU.,GREEN(EEC) OR 10-2 t1E-B W/G(OR NM-1/1,1414N11IIWN-2,SOLID CU. J1.1 3/4 INCH EMT' EXTERIOR (1) 314 INCH EMT EXTERIOR (1) 3/4(NCH EMT(Not Required for LIF-R or NM-SCAM) INTERIOR EXTERIORBLUE RAVEN (1) NA+1-$V,+/G«C4J. 31�7AAc 6 2IOVAC 1403 N. Research Way ELECTRICAL NOTES: Orem, UT 84097 (1) 3/4INCHEMT EXTERIOR ALL CONDUIT TO BE RAN AT LEAST 7/8 IN.ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. 800.377.4480 W W W.BLUERAV ENSOLAR.COM DESIGNER NOTES: AC DISCONNECT TO BE LOCATED WITHIN 10 FEET OF THE UTILITY METER. CONFIDENTIAL-THE INFORMATION LOAD SIDE BREAKER IN MSP,INTERIOR POI.DERATE MAIN BREAKER TO ACCOMMODATE THE REQUIRED PV BACKFEED. HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MAIN BREAKER TO BE DOWNSIZED. (32)()Cells Q.PEAK DUO BLK ML-G10+400 IN CONNECTION CT ON WRECIPIENTS TZ ORGANIZATION, SALE AND P EXCEPT ENPHASE IQ COMBINER 4 UL 1703 COMPLIANT (E)200A MAIN SERVICE PANEL WARNING LABEL TO BE PLACED AT X-IQ-AM1-240-4 (32) En tease IQ8PLUS-72-2-US USE OF THE RESPECTIVE EQUIPMENT, (N)175A/2P MAIN BREAKER MAIN BREAKER DEAD FRONT: (soLAR LOAD ONLY) WITHOUT THE WRITTEN PERMISSION 4"x4"x4"PVC JB-1 EZ SOLAR UL 1741 COMPLIANT OF BLUE RAVEN SOLAR LLC. "MAIN BREAKER DOWNSIZED PV AC DISCONNECT JUNCTION BOX JUNCTION BOX (N)175A/2P TO 175A FOR PV BACKFEED. NON-FUSED (N)20A/2P JgLi JB_1LI _ (1)CIRCUIT OF p L u LOCKABLE,VISIBLE OPEN Li Lz Lz NAC/C P ,� DO NOT UPSIZE. 60A,240v,2-POLE EGG EGC -�__ 11 MODULES r` N ENVOY _ CERTIFIED (E)LOADS * • FROM BREAKER TO BE LOCATED AT OPPOSITE END OF BUSSING ` CERTIFIED 1 JUNCTION N —p/1p— PV INSTALLATION ❑ ❑ FROM MAIN BREAKER (N)SOA/2P 11 BOX /� (N)20A/2P n PROFESSIONAL (t �n [—__ u , JB 1 a _ _ (1)CIRCUIT OF Scott Gurney \ ❑❑❑) N21 1 ' �� LZ O Lz I EGC EGC \ \ 11 MODULES 5NEGC #PV-011719-015866 EGC -♦ EGC r CONTRACTOR: 120/240 VAC 15 4G alb N s 2BRS FIELD OPS 60HZ �- 1 PHASE (N)20A/2P L� �� JB-1 L, _ (1)CIRCUIT OF 800-377-4480 TO UTILITY — __i_-_ 10 MODULES G ----J r I L__J 3 2 1 I I < 0 O I I -�(E)GROUNDING ~ Noo ELECTRODE(S) : mi 2 CO CO a) :t ( at, )Y N r4 ... 0 EN WW cis 0) N I U- -a N ... Z C Ni N U) ( as c y -: 44 4 A o o I— ct O -o U)N N /) N NB # 'j = C 00 ) V V ' ' , s - < y'4. ; DRAWING BY: { Brendan Fillmore w"- r PLOT DATE: �s April 13, 2023 �x � Y l �i PROJECT NUMBER: INTERCONNECTION NOTES BE USED TO ��,� . SHALL METHOD(S) 17 FOLLOWING 7 5 5 THE 3 705.12(6)(3) *,'il DETERMINE THE RATINGS OF BUSBARS: (2)WHERE TWO SOURCES, .; �, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SHEET NAME: SOURCE,ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE ELECTRICAL POWER-SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF REVISION: PAGE NUMBER: THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. UTILITY COMPANY: Portland General Electric (PGE) PERMIT ISSUER: City of Tigard 0 PV5 Nit.'-' , BLUE RAVEN t '' I#0011111104.If,:s* 2r_.. r... .,, r ., JY �i'r °"fix °£} € �� ,� .. r 'sue / .. ek s:a' l@ 1 s r., W < ,;A Y # 1. S.. 3 f ''. mil" '*4i' ,ate ./ ',. „a � ,� ,A.t 's 1403 N. Research Way • .,xm �..� �. '"'` s y �� � � Orem, UT 84097 ": 3 f, s/ e '' ry � is y 800.377.4480 RESIDENTIAL ELECTRICAL LDA©CAi.CUlAT1tJN5 y WWW.BLUERAVENSOLAR.COM NEC 22i3.82 OLAR NOR € Li ` f, CONFIDENTIAL-THE INFORMATION �EIEtA.�GHTIN ,RECEl�>A ,A#+1t�SICti+ A APPLIANCE LOADSa , � ♦ f , x d HEREIN CONTAINED SHALL NOT BE NEC�.a 2�B}{ij& 2I x;` mae ,,, ;s'„le :-"- —,' ", ' USED FOR THE BENEFIT OF ANYONE SQ. X. VA = VA - a ¢ SHALL EXCET BE DISC OSEDPT BLUE RAVEN SIN WHOLE OR . d„f // IN PART TO OTHERS OUTSIDE MAIlAPPL1ANCE , r G (1500VA ;: VA ' y!* ""' -t `''� -, IN RECIPIENTS ION WITH THE ,EXCEPT APPLIANCE � ..� � a ,�^ ,/f� _,ra';.�i"f �#��#� y 1 ; f;', IN CONNECTION WITH THE SALE AND ( VA = iscio VA ,y � USE OF THE RESPECTIVE EQUIPMENT, t � " F ss WITHOUT THE WRITTEN PERMISSION t3421. ri.=_. T OF BLUE RAVEN SOLAR LLC. CONKING EQUIPMENT AND APPl1ANCE LOADS �r L. : _ .. _ y � 8 r" r, .. NEC220.82(8)(3 i - 4, • I ,ff. XI AB EP 40 7OVAit. ct � � � °� CERTIFIED Water Healer 3Q Range 5t�0 VA ,. r. u,r PV INSTALLATION Qryer 3Q 5E100 VA k V WW it,St PROFESSIONAL Other 1, V Appliance 20 1 t?VA ^ - m Scott Gurney sasaR at f f #PV 011719 015866 Microwave �$ VA a - £� , `s ir y Dishwasher 15 1200 VA ;Ix �; _ �� � CONTRACTOR: Disposal 15 800 VA _ w ;,, t, 15 BRS FIELD OPS x a • a r 800-377-4480 3, Y _ �$ SL 4 .; U U P s3 . 44. CV Q (J) N • ��VA t � _ • � � c� co di N -w- ---, I � � N W LLI TOTALGEN AL LOADS 32221 VA T cat r� ���,,� LL � N N TOTAL j��wr...�x FOR FIRST 10 kVA ANyD 4014 REMAINDER 188��yy�� Z RI g to N cc a)z Heatictg and Air Condltiolload3 NEC 2C) - W J cm °� H H Air Conditioning Unit 0 VA O TD u) -0 >- >- Air Conditioning Unit 2 {)VA Cl) N z, V) co Heating UnitI;Sunity, 120 92 VA __ U co � V V MAX VALUE OFHEATING 1 It AIIt CONDONING LOADS 9216 VA V r I . Q G t 28�4 VA DRAWING BY: TotalTotal VA ' 117 Brendan Fillmore ps PLOT DATE: April 13, 2023 PROJECT NUMBER: 735175 SHEET NAME: LOAD CALCS REVISION: PAGE NUMBER: 0 PV5.1 , . MODULE SPECIFICATIONS QCeUIs Q.PEAK DUO BIX(ML-G10+400 DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 400 W TEMPERATURE DATA SOURCE ASHRAE 296 AVG.HIGH TEMP MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.3 A AC MODULE VOC 45-3 V DC STATE Oregon JUNCTION BOX(11 MAX.CURRENT(ISC X1 29)= 16.6 A AC MODULE VMP 37.13 V DC CITY Tigard CONDUCTOR(TC-ER,COPPER(90'C))= 12 AWG BLUE RAVEN MODULE IMP 10.77 A DC WEATHER STATION PORTTAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 11.14 A DC ASHRAE EXTREME LOW TEMP('C) -6' ANS.TEMP,AMP.CORRECTION= 0.91 VOC CORRECTION -0.27%/'C ASHRAE 2%AVG.HIGH TEMP('C) 36 ADJUSTED AMP.= 27.3 > 16.6 1403 N. Research Way •VMP CORRECTION -0.34%PC JUNCTION BOX TO MAX.SHORT CIRCUITCURRRENT(ISC)= 13.3 A AC Orem, UT 84097 800.377.4480 SERIES FUSE RATING 20 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 OR 4 CIR 5 CIR 6 JUNCTION BOX(2) MAX.CURRENT(ISC XL25)= 16.6 A AC WWW.BLUERAVENSOLAR.COM ADJ.MODULE VOC @ ASHRAE LOW TEMP 49.1 V DC NU is ER OF MODULES PER MPPT 11 11 10 CONDUCTOR(UF-B,COPPER(60'C'))= 10 AWG CONFIDENTIAL-THE INFORMATION ADJ.MODULE VMP(4 ASHRAE 2%AVG.HIGH TEMP 31.7 V DC DC POWER RATING PER CIRCUIT(STC) 4400 4400 4CCO CONDUCTOR RATING= 30 A HEREIN CONTAINED SHALL NOT BE USED ANYONE TOTAL MODULE NUMBER 32 CONDUIT FILL DERATE= 1 EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR MICROINVERTI=RSPECIFICATiONS En phase IQS+Mlcroinverters STC RATING OF ARRAY 12800 AMB.TEMP.AMP.CORRECTION- 0,91 IN PART TO OTHERS OUTSIDE POWER POINT TRACKING(MPPT)MIN/MAX 30 - 58 V DC AC CURRENT @ MAX POWER POINT(IMPf 13.3 13.3 12.1 ADJUSTED AMP.= 27,3 > 16.6 RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND ( MAXIMUM INPUT VOLTAGE 60 V DC MAX.CURRENT(IMP X 1.25) 16.6375 16.6375 15.125 : JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT IS 13.3 AC C)= A USE OF THE RESPECTIVE EQUIPMENT, MAXI MUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 2{I 20 COMBINER BOX(3) MAX.CURRENT(ISC X125)= 16.6 A AC WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. MAXIMUM USABLE DC INPUT POWER 440 W MAX.COMB.ARRAY AC CURRENT(IMP) 38.7 CONDUCTOR(UF•8.COPPER(60'C))= 10 AWG MAXI MUM OUTPUT CURRENT L21 A AC MAX.ARRAY AC POWER 9280W AC CONDUCTOR RATING= 30 A AC OVERCURRENT PROTECTION 20 A CONDUIT FILL DERATE= 0.8 NABCEI MAXIMUM OUTPUT POWER 290 W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. ✓RISE(V) VEND(V) %VRISE AM&TEMP.AMP.CORRECTION= 0.91 CERTIFIED CEC WEIGHTED EFFICIENCY 97% .VRISE SEC 1(MICROTO JBOX) 39.6 12 Cu. L76 241.76 0.7396 ADJUSTED AMP.= 21.84 > 16.6 VRISE SEC.2(JBOX TO COMBINER BOX) 40 lO Cu, 1.35 241..35 0.56% COMBINER BOX TO INVERTER RATED AMPS= 38,7 A AC PV INSTALLATION AC PHOTOVOLATIC MODULE MARKING(NEC 52) VRISE SEC 3(COMBINER BOX TO POI) 35 6 Cu. L38 241-38 0.58% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS XL25)= 48.4 A AC PROFESSIONAL Scott Gumey NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 449 244.49 L8794 CONDUCTOR(THWN•2,COPPER(75'CTERM))= 6 AWG #PV-011719-015866 NOMINAL OPERATING AC FREQUENCY 47.68 HZ AC CONDUCTOR RATING= 65 A MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC . a.54) CONDUIT FILL DEFLATE 1 CONTRACTOR: MAXIMUM AC CURRENT 1.0 A AC 'AC OUTPUT CURRENT 38.7 A AC AMB.TEMP.AMP.CORRECTION= 0,91 BRS FIELD OPS 800-377-4480 MAXIMUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 VAC - ADJUSTED AMP.= 59.15 > 48.4 00 Q 0 GROUNDING NOTES WIRING&CONDUIT NOTES ZO 1.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690.47]AND[NEC 250.50-60]SHALL BE 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE PROVIDED. PER[NEC 690.47],THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE APPLICATIONS. ~ CO CO USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR(USE CQC r-+ • INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE POLARIS BLOCK OR NEUTRAL BAR). G USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 3.ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS DISALLOWED ABOVE :ttCZ CC1) 0) N 2.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN LIVE PARTS,MEYERS HUBS RECOMMENDED THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER) IF SMALLER THAN#6 AWG COPPER WIRE 4.UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF 0 NN C N N PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SURFACE IN ACCORDANCE WITH[NEC 110.2,110.3(A-B)]. U. - SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER[NEC 250.64(C)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE Z_ C N N 3.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. C COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 6.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR CABLE LISTED AND CC IY) 0 4.PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 250.122],AND ALL METAL IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT;ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS W � � LJ.I W 0) PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.46]. REQUIRED. -IO N N 5.MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC 690.42]. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8]FOR MULTIPLE 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A CONDUCTORS. MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 8.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8"ABOVE (- czCD -0 N N 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE (n t N ai MANUFACTURER'S INSTALLATION INSTRUCTIONS. 310.15(B)(3)(A)],&[NEC 310.15(B)(3)(C)]. U V V 8.ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN 9.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV RESISTANT,AND UL GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP V T < 0 9.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EDGES. EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, DRAWING BY: 10.GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR STRANDED,AND BARE WHEN WET AND UV RESISTANT,RATED FOR 600V EXPOSED. 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND Brendan Fillmore 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO 12.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION DAMAGE). 13.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS PLOT DATE: 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN(OR MARKED 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC GREEN IF 4 AWG OR LARGER). POSITIVE-RED(OR MARKED RED),DC NEGATIVE-GREY(OR MARKED GREY) ' April -13, 2023 13.ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE 15.POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: GROUNDED BUSHINGS AT BOTH ENDS. DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED 16.AC CONDUCTORS>4AWG COLOR CODED OR MARKED:PHASE A OR L1-BLACK,PHASE B OR L2-RED, PROJECT NUMBER: ACCORDING TO[NEC 250.166],MINIMUM 8 AWG WHEN INSULATED,6 AWG WHEN EXPOSED TO DAMAGE. PHASE C OR L3-BLUE,NEUTRAL-WHITE/GRAY 735175 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND 'USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH[NEC 250.134]OR[NEC 250.136(A)] -.USE-2 IS AVAILABLE AS UV WHITE REGARDLESS OF VOLTAGE. 17.RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, SHEET NAME: FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING ELEC CALCS MEANS SHALL COMPLY WITH[NEC 690.13]AND[NEC 690.15]. 19.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18'BELOW ROOF SURFACE COMPLYING WITH[NEC 230.6(4)]AND SECURED NO GREATER THAN 6'APART PER[NEC 330.30(B)]. REVISION: PAGE NUMBER: 0 PV6 STANDARD LABELS ADDITIONAL LABELS LABEL 1 RAVEN AFOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE ELECTRIC SHOCK HAZARD OPEN POSITION. LABEL 3 (2017 NEC POSITION. (B)] DUAL POWER SUPPLY IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL 1403 N. Research Way TERMINALS ON THE LINE AND [2020 NEC 690.13(8)] ANYWHERE THAT IS POWERED BY BOTH THE UTILITY Orem, UT 84097 AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL LOAD SIDES MAY BE ENERGIZED SOURCES:UTILITY GRID AND AND SUBPANELS.[NEC705.12(8)(3)] 800.377.4480 IN THE OPEN POSITION PV SOLAR ELECTRIC SYSTEM WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR THE DISCONNECTING MEANS AS A POWER SOURCE IN PART TO OTHERS OUTSIDE AC DISCONNECT A AND WITH THE RATED AC OUTPUT CURRENT AND THE RECIPIENTS ORGANIZATION,EXCEPT NOMINAL OPERATING AC VOLTAGE. IN CONNECTION WITH THE SALE AND (2017 NEC 690.54] USE OF THE RESPECTIVE EQUIPMENT, RATED AC OUTPUT CURRENT 38.72 A [2020 NEC 600.54] WITHOUT THE WRITTEN PERMISSION NOMINAL OPERATING AC VOLTAGE 240 V OF BLUE RAVEN SOLAR LLC. LABEL 3 NABCEP AIF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL CERTIFIED » -� >- ANYWHERE THAT IS POWERED BY BOTH THE UTILITY DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL AND SUBPANELS. PV INSTALLATION (2017 NEC 705.12(B)(3)J LABEL 10 1 SOURCES:UTILITY GRID AND , PERMANENT PLAQUE OR DIRECTORY TO BE PROFESSIONAL [2020 NECNEC705.12(B)(3)J f, LOCATED AT MAIN SERVICE EQUIPMENT DENOTING Scott Gurney PV SOLAR ELECTRIC SYSTEM POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: LABEL 4 ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN BRS FIELD OPS AAPPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METER. SERVICE DISCONNECTING MEANS. TO THE BACK-FED BREAKER FROM THE POWER [2017 NEC 705.10 AND 690.56(C)(1)(a)] 800 377-4480 POWER SOURCE OUTPUT CONNECTION SOURCE. [2020 NEC 705.10 AND 690.56(C)] DO NOT RELOCATE [2017 NEC 705.12(B)(2)(3)(b)J [2020 NEC 705.12(B)(3)(2)] THIS OVERCURRENTf LABEL 11 DEVICE yArt PERMANENT PLAQUE OR DIRECTORY TO BE0 0 LOCATED AT AC COMBINER PANEL. •• < 0 PHOTOVOLTAIC SYSTEM [2017 NEC 110.21(B)] Z COMBINER PANEL [2020 NEC 110.21(B)] 0 co co DO NOT ADD LOADS Q CI) N c� CO N O N 0 c N Ili IlitL -0 c� NN SUBPANEL fV � UTILITY MAIN (IF INTERCONNECTION AC PV PV COMBINER Z N co c N N METER SERVICE PANEL IS MADE HERE) DISCONNECT METER BOX CC CD 2 cn . SOLAR PV SYSTEM EQUIPPED LABEL 6 00 00 00 M _JCn BUILDINGS WITH PV SYSTEMS SHALL HAVE A N i (n Co WITH RAPID SHUTDOWN PERMANENT LABEL EQUIPMENT LOCATION TOTED AT W CH EACH THE SERVICV SYSTEMSE O 0 0 0 0 D .2 c •D) 0 0 TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY 0 C T Q SWITCH TO THEAl IF BREAKER0 ) 'OFF'POSITION TO ,�,,,��„� VISIBLE LOCATION AND SHALL INDICATE THE LOCATION0 C SHUT DOWN PV SYSTEM rs , OF RAPID SHUTDOWN INITIATION DEVICES. 4 IS USED O DRAWING BY: AND REDUCE SHOCK HAZARD [2017 NEC 690.56(C)(1)(a)] - IN THE ARRAY 1 [2020 NEC 690.56(C)] io Brendan Fillmore OOR PLACARD PLOT DATE: LABEL RAPID SHUTDOWN SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT April 13, 2023 SWITCH FOR SWITCH -0 [2017 NEC 690.56(C)(3)] PROJECT NUMBER: SOLAR PV SYSTEM [2020 NEC 690.56(C)(2)] -0 735175 LABELING NOTES SHEET NAME: 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL LABELS 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE HANDWRITTEN[NEC 110.21] DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. 0 PV7 i BLUE RAVEN powered by MECHANICAL SPECIFICATION 1403 N.Research Way Orem,UT 84097 Q.ANTUM /DUon Format 74 OAs 41.1inx 1.26in(including frame) (1879mm x 1045 rum n 32 rum) " eB 0• Bn'"' aaomm, 800.377.4480 Weight 48.51bs(22.0kg) - t l ra e a as mmt WWW.BLUERAVENSOLAR.COM Front Cover 0.13in(3.2mm)thermally pre-stressed glass with 1rtv.m,m, a anti-reflection technology ..o. ws.a.av asm i 1 .»- CONFIDENTIAL-THE INFORMATION Back Cover Composite film a3.2-aom] HEREIN CONTAINED SHALL NOT BE Frame Black anodized aluminum I USED FOR THE BENEFIT OF ANYONE ® ° •aws ai EXCEPT BLUE RAVEN SOLAR NOR Cell Be 22 monocrystalline Q.ANTUM solar half cells SHALL IT BE DISCLOSED IN WHOLE OR Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in IN PART TO OTHERS OUTSIDE (53-101mm x 32-60 rum x 15-18mm),IP67,with bypass diodes va,-� ix0827126.... RECIPIENTS ORGANIZATION,EXCEPT Cable 4mm°Solar cable;(+)249.2in(1250mm),(-)z49.2in(1250mm) .holes 1 <.ammo wato wia °+I IN CONNECTION WITH THE SALE AND Connector St5ubli MC4;IP68 ' mm USE OF THE RESPECTIVE EQUIPMENT, f L, P a' ° r°°-)nai I°y.taa.., WITHOUT THE WRITTEN PERMISSION °o°"°` 'I OF BLUE RAVEN SOLAR LLC. Q.PEAK DUO BLK ML-G1O+ ELECTRICAL CHARACTERISTICS AnPv NABCEP Controlled POWER CLASS 385 390 395 405 385-405 TOVRheinWID 1d MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-O W) '''"CERTIFIED +• Power at MPP' BAH [W] 385 390 395 =4O 405 CERTIFIED D 1111232816 Short Circuit Current] Isc [A] 11.04 1107 11.10 r' 4;. 11.17 ENDURING HIGH w. Open Circuit Votage' Voc [v] a5.le 45.23 45.27 '"-4�,��',�>,, 45.34 PV INSTALLATION YR � � PERFORMANCEi& 5 EOPORESEAecH Mir Q CurrentatMPP mP° [A] 10.59 10.85 1071 Yt477-- 10.83 PROFESSIONAL TOPBRANDPV I►/ Voltage et MPP VM„ [V] 36.36 36.62 36.88 '9Y7.3 37.39 MODULES �� Efficiency- rl [%] 219.6 >_19.9 >_20.1 204 >_20.6 Scott Gurney B...E #PV-011719-015866 • MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' USA Warranty "`,2021 Q CELLS Power at MPP Pah] [W] 288.8 2926 296.3 ,"SO .d.,,.: 303.8 CONTRACTOR: erommca,�,u„m,,. Yield Security E Short Circuit Current Isc [A] 8.90 8.92 8.95 [ 8.97 9.00 BRS FIELD OPS £ Open Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 ripp ffo�pp CC Current at MPF IN°° [A] 8.35 8.41 8.46 •,z851 i 8-57 30.5'4.70-V700 (7 BREAKING THE 20%EFFICIENCY BARRIER n1 I Q.ANTUM DUO Z Technology with zero gap cell layout Voltage at MPP V,,,p, [V] 34.59 34.81 35.03 36.15. ` 35.46 11 boosts module efficiency up to 20.9%. 'Measurement tolerances P„,,,±3%;Isc:Voc v5%at STC:1000 W/m',25±2°C.AM 1.5 according to!EC 60904-3.'800 W/m',NMOT,spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ^ THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY a At least 98%of nominal power during - FLJ-I Q CELLS is the first solar module manufacturer to pass the most comprehen- W W first year.Thereafter max.0.5% i sive quality programme in the industry:The new"Quality Controlled PV"of LL a degradation per year.At least 935% ,, ,-- z of nominal power up to 10 years Al - z the independent certification institute TOV Rheinland. least 86%of nominal power up to f le 25 years. ° Wz INNOVATIVE ALL-WEATHER TECHNOLOGY as All data within measurement tolerenc- w ., am .ee mae 0 w es.Full warranties in accordance with �.�: Optimal yields,whatever the weather with excellent NO C-J the warranty terms of the r CELLS aaaoiarvcetw,m 7 low-light and temperature behavior. 8 • , ..,. b sales organisation of your respective country. noses Typical module performance under low irradiance conditions in _ ENDURING HIGH PERFORMANCE comparison to STC conditions(25°C,1000W/m') m Long-term yield security with Anti LID Technology,Anti PID TEMPERATURE COEFFICIENTS Technology',Hot-Spot Protect and Traceable Quality Tra.QTM'. Temperature Coefficient of I.;_ a [%/K] +0.04 Temperature Coefficient of V;,c 13 [%/K] -0.27 Temperature Coefficient of PM,,. y [%/K) -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5 4(43±3°c) i .� EXTREME WEATHER RATING 0 ([/7 High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN11 7/ high snow(5400 Pa)and wind loads(4000 Pa). g. Maximum System Voltage V,., [V] 1000(IEC)/1000(UL) PV module classification class 11 ,3 rA Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI JUL 61730 TYPE 2 ri A RELIABLE INVESTMENT Max.Design Load,Push/Pull" [Ibs/ft'] 75(3600Pa)/55(2660Pa) Permitted Module Temperature -40°F up to+185°F p 7-cxvo. Inclusive 25-year product warranty and 25-year on Continuous Duty (-40°C up to+85°C) o r( Max.Test Load,Push/Pull' [Ibs/ft°[ 113(5400Pa)/84(4000Pa) ,L linear performance warranty2. 'See Installation Manual t NNR 126CHNAR 'APT test conditions according tolEC/TS62804-1:2015,method A(-1500V,96h) QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION i' TECHNOLOGY CELL TECHNOLOGY CELL TECHNOLOGY 'See data sheet on rear for further information. - UL61730,CE-compnant, _ ;/., ��y//��� 'r�3S77I _ DRAWING BY: Oualiry Controlled PV-TUV Rheinland, i.�, �1/ ® LJ O-O I'<0'NcII IEC 61215.2016,IEC 61730:2016, A• U.S.Parent Ro.9,e93,215(solar tens), St" ( E Horizontal 76.4in 43.3in 48.0in 16561bs 24 24 32 THE IDEAL SOLUTION FOR: C•„„,„US ♦ packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules - AiRooftop arrays on 1 residential buildings a BIM ems.» PLOT DATE: Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. CELLS hlanwpo CELLS America,Inc. PROJECT NUMBER: Engineered in Germany 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA TEL+1 949 748 59 96 I EMAIL inquiry@us.q-cells.com WEB www.q-cells.us SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ._.. V V BLUE RAVEN EN PHASE. DATA SHEET IQ8 and IQ8+ Microinverters 1403 N.Research Way Orem,UT 84097 INPUT DATA MCI 108-60-2-US • Li - 800.377.4480 Commonly used module pairings' w 235-350 235-440 WWW.BLUERAVENSOLAR.COM Ill Module compatibility 60 cell/120ha1f-cell 60-cell/120haff-ce8.66-cetV132 half-cell and 72-cell/144 CONFIDENTIAL-THE INFORMATION «. half-Cell HEREIN CONTAINED SHALL NOT BE MPPT voltage range v 27-37 ?9-45 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR Operating range v 25-48 25-58 SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE Min/max start voltage v 30/48 30/58 RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND Max input DC voltage v 50 60 USE OF THE RESPECTIVE EQUIPMENT, Max DC current'[module Isc]Overvoltage class DC port A 15 WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. II DC port backfeed current mA 0 it PV arrayconfiguration 1x1 Un rounded array;No additional DC sideprotection required; N A BC E P 9 AC side protection requires max 20A per branch circuit r y,at I Ili OUTPUTDATA IACI 108-60-2-US P'' '.. 2 US CERTIFIED ! Peak output power VA 245 300 PV INSTALLATION Max continuous output power VA 240 290 PROFESSIONAL Nominal(L-L)voltage/range' v 240/211-264 Scott Gurney Max continuous output current A 1.0 1.21 #PV-011719-015866 IQ8 and I Q 8+ Microinverters Nominal frequency Hz 60 CONTRACTOR: Easy to install Extended frequency range Hz 50-68 BRS FIELD OPS Our newest I08 Microinverters are the industry's first microgrid-forming,software- • Lightweight and compact with AC short circuit fault current over 2 385-498 6700 defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors 3 cycles Arms power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication Max units per 20 A(L-L)branch circuit' 16 13 •is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components Total harmonic distortion <s% microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times • Faster installation with simple Overvoltage class AC port III to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling AC port backfeed current mA 30 energy systems. Power factor setting 1.0 High productivity and reliability Grid-tied 1 power factor(adjustable) 0.85 leading-0.85 lagging • Produce power even when the Peak efficiency x szs 97.6 Enphase grid is down* CEC weighted efficiency S 97 97 • More than one million cumulative 1; hours of testing Night-time power consumption mw 60 6' year hmrted rf y' warranty MECHANICAL DATA • Class II double-insulated Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability enclosure Ambient temperature range -40°C to+60°C(-40°F to+140°F) Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Relative humidity range 4%to 100%(condensing) • Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- DC Connector type MC4 and analysis software. leading limited warranty of up to 25 years. powered PV modules Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Microgrid-forming Weight 1.08 kg(2.38 Ibs) 0 • Complies with the latest Cooling Natural convection-no fans advanced grid support** Approved for wet locations Yes CE WI (ElED • Remote automatic updates for P Pollution degree PD3 DRAWING BY: the latest grid requirements Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Connect PV modules quickly and easily to IQ8 Series 108 Series Microinverters are UL Listed as • Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with Environ.category/UV exposure rating NEMA Type 6/outdoor cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles COMPLIANCE manufacturer's instructions. • Meets CA Rule 21(UL 1741 SA) PLOT DATE: CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 requirements Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to PROJECT NUMBER: ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other 'Only when installed with IQ System Controller 2, manufacturer's instructions. names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. (1)No enforced DC/AC ratio.See the compatibility calculator at https://link.enphase.com/module-compatibility •'108 and IQBPlus supports split phase,240V (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required IQ8SP-DS-0002-01-EN-US-2022-03-17 installations only. by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2022-03-17 SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: sS ' 1 BLUE RAVEN IQ Combiner 4/4C Enphr.i5e NetoJorking MODEL NUMBER 1403 N.Research Way Orem,UT 84097 '4,0,10..,RallillA*:*.tl.*'1::Cl4Ill'illi..ji *l—T-04t':4,r' r*F.;,I :'It7. ,.,,llta*.* 'O*:'"!'''1:' ** *4Kii.i4 * •41 71::.: ( .*'.:14,.0..!.„*0- #01..4",.!*.:0,10.. 0.,#01'!1.09.,‘;Y''',- !i 2 0 800.377.4480 . )1240044,01#01,1:60.**1:: ":.:•' -''' , '-%.--11.'.-.1:- !"I.C '.''.:,-'''.-: ' ' . , ', -' ;''- '- ;. ' .,''.. ,:',:,;:: ' ',- ::::.-,, - ;,',-.- ' :, ,--<- : ' . '- , ,. WWW.BLUERAVENSOLAR.COM it;cornoiner 4C n)C:qmkuruP,4C loath IQ Cmle444T Pt 0441 circuit Ociare In(thiiegralto reterror wade Re deddir,t(inn merte.r.n,t3(Alvil CV;ila..ti 0.5'10 CONFIDENTIAL-THE INFORMATION S-1((akst.74e,4C tow,Cliet$t-itYVtott mot'titCtt10411!.2 5%1 It tett'Aett Mobile C.. er ce4(ilat rr.t4tto‘t,CALLI1DOEM-Ylt,06.„.5:P-05k,3 rAi-20c),...p.14, HEREIN CONTAINED SHALL NOT BE IQ,CoMbiner ,4/4C The IQ Combiner 4/4C with IQ Gateway and x.7-70.a w.740-4C.i ikt.€154 7 lei mcluortl.-;a1pt.otitt celt rflocirrn 1<tr tsyster,N urt In eT0mir.tnitverrtt,z.tAwnitaltri-e.ir.the 1/S,C.one.da,teleiocn,10-40..rtkr-01,a r4 04 US vitoot7,1Evtds,whoro Ihci. tl Utit'qUatft cifliilai siKotro ihr(nttallgion area`,.Incluilin, a iii7en,(.04r(lurid In meth thit USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR qmeurated (TE-r,ili cell modem (included iQ 0....a.ory and IQ SOletti Co rstmlle ar..I 1 o dentsi 11441 SHALL IT BE DISCLOSED IN WHOLE OR . , ACCESSORIES AND REPLACEMENT PARTS (not included,ender separately) IN PART TO OTHERS OUTSIDE only with IQ Combiner 4C) corisofidateS RECIPIENTS ORGANIZATION,EXCEPT SupPerted rnscrolnearners tO6.107.and 1138,(Do hal MIX KIWI 34470(rtverter3 eat+148) IN CONNECTION WITH THE SALE AND Jnterconnect:on equipment irit0 d single corurnunJcilJons 4/1 USE OF THE RESPECTIVE EQUIPMENT, C'Ot.41AS-CELL MOC4(1.4-M1-O4 ,inclueats 1:0141.(flit,,II-al and CatielODElet-MI-07J-SP-05 wit)*.5-rtAll Spn411 tilta panWITHOUT THE WRITTEN PERMISSION enclosure li streamlines IQ Microirwe:•rterS and OF BLUE RAVEN SOLAR LLC. CELIMODEta,Mi,Oty5P,05 4 G'hued 11 L'Nil cc ttutnt twoCtrrrt well,.til^o.jr Sprim otAtit ptan storage instatiations by providing a consistent, CEL(140OF14 4,11,04 4+1 OS ,4G.13-9 ,0 LTE*417 tetitulpt modern w.lt,..5,trear attT dattf()two Circon Bracket% Supporte'Eatart Mitt 0R215,DR720,09230,Bb2.40,IWZ50,and 8060 Estoril breakers nre-wJfed solt.:..iton for residential applications EiRk.10A.2440V Ciircua breiakan.7 Pate,.104,Eaten 88110 X--ABC-E1) aRreiSA,2-24Ery Caraill breaker,2 ante.,lbA,Eaton Bin lb It pliers tip to four 2-pole input circuits anl ORK-29A-2P-24(TY COcult breaker,Z po4e,20a.,Eaten BRNO Circuit Citeaket,2 poke,Ibk„Eaton 9Pa158 with hold down kil%Waal CERTIFIED ,. ,1N,4-0,„..it,-,,,,.,,„,,-„':'„ Eaton BR series busbar assembly cippe,--zo*-2e24av-,0 Circell bracket.7.pole,20A,Eaton(W22064401 hyoid dosio SP support , 41 . ,„*.'.,.4,, ,',,',,- ,'., x A.SOLARSH ILL ttES gitiolacemervi Sotar K.brefri Ito If)Combl, r 4 i.ic PV INSTALLATION ,,;,i. •.::--.4"'',,,,'?:, ..f4..."':: ''..--' XkPLUG-120-3 kreesseriretartAnole for Power Law Caniorin 10 Combiner 4i4C(required fel:EFL C-0 It PROFESSIONAL ,:-77, ••••-•.-,>;-A,.c,,,giw4V,..Q.zR X-teeNA-HLI.12SA He(4-&mei 4(i lot(elan ttrtint toedtket with s.t.qtrortt Scott Gurney --'•'-:44::::Ifttal #PV-011719-015866 %u monikoorko CT A.pcit or 200A split cora currant tranktorrners CONTRACTOR: Smart ;CTIOO'S,P1.111rof=72130-riAtAP) ., „ 0 .-''•-,',•,•:;:!iiii'i4i:',4.-,t;,`,',';',. ELECTRICAL SPECIFICATIONS BRS FIELD OPS „ ,„-:, • Includes IQ Gateway tor c rri omun nd ication a control Rating Coot-mogul drAS .... . ,--- -,,,-',..-' • k 385-498-6700 miudes MoMobile Connect cellular modem Sy51R-pi 4fAliapie 1701240VAC 60 I-I; (C,EW•40DEM•ki11•46-SP-05),included only with r,•,; t IQ Combiner 4C Eaton BR sol.es Duelmot,romp 12.5k, . . ... „ . • includes olttr shield to match Enphase IQ Battery I,5vs ..4 cm-11,1 tittrw9 S.P. aesthetics and deflect heat 141k nordarruous contra ettirc Popo tnitn Pvta.strisocl 64A V.1 - • Supports liki•Fi,Ethernet,or cellular connectivity mai< furnitt'otr_wit r4tir9 ttof.dput( vae 't:4 - • Optional AC receptacle available for PLC bridge &ranch corciets(soup and/wane ape) UP tie toul'2-pyleElliOCI SR senes(I iambi:ter,Genera:bon'RIG)breakers PHI(not tecludiett) i t!- i • Provides production metering and ccmsurnplion Ma(total branch raredil inee.??,..e.,",(alto()(ndut) ROA n.f distritAiled 9eneratiniv lilFiA wilt)tQ G4104,ay bleav2fai.ehided monitoring Pa Gaterreay*esker 10uk,at't SA rating PErSiernencrEirten tockstled (i ( .'.. (4?„ Plee(adion rtt-efertrto CT 200A.9 cit,d c tire o•t -1.1(.(alded and Attaet,1 to tO Gotrwitry c, , ,.. Simple MECHANICAL DATA Dirnentiona(WarbiN 3'7.5cm r MO cm s 16T3-,cm 04,75 in e 14,5(do 4,53in).height la S;u5 ern tn.%in)NO mount-kw bracket-It i Mounts on single stud with centered brackets. r , weeght P St 11C,5 10?;) X2-10AMI-260-4C(IEEE 1547i7:018) It• , • Supports bottom,back and side conduit entry I 1 ti .i... • Atlows up to four 2 pole branch circurts for 240VAC Cntbsent ternmeatore range ---40.0 to-vatC(40,F to 115•7) OlUg•in breakers(not included) Coon° Nom*.cetivetikV1,Phil neat shwa 1.1,,,,',1,, • 80A,Ica&ev or storage branch circuits Enctoture environmental rating Outdoor,.HATI-certiramt,litfMA type 3il_pottcertlion.to tOnStriithOn , .:. Wore,:11.C.t., • 70A It,tail t,e ahmr l'plJiS 14 to 4 ittlif,coppet toodur:itytt (..( „ . ii ((OA breaker branc/l input'4 W Igt Av.;cooper(..n(nduclei:q . Reliable • soiil.ivia coenC:ried dutpui iS In 2,i0 kitt.'Cii„tuctp.ot ctmdoettOnt. Keutrial 4nd ott,inel.IA lu 1.t0 c.pittot 0rttItttt:IWt • Durable NRTL-certrfied N E MA type 3R enclosure • kw rip(olio,.weal code(eouireentids tor tonclutide Siiield Five,year limited warranty AtIkucie Upla IWO mem ili,142 feel) :,,,, 4- •t,t Two years labor reimbursement program coverage i..,, :r INTERNET CONNECTION OPTIONS included for bath the IQ COrTibiner SKU"S . Ul listed tnuagratee Wi-FI tEEE.SOZ.1113tgin x-IQ...Ami.1404 e.', ' r ..--,, -00.;riiii,-------ww,riiri.r-e,r,;.....„.:re4-.*: t.:ettuta, CE1114000(14,11.7.1eSP,05,CE.11.140DE14,M1ii(loi41.05(4G b-ased LTE•iNI I cellular FrtDotttrot.Nte,:tt,e tool do Inotoe Conote.:1 • X 2-IQAM1-240-4 and X2-IQ,AM.1-240,4C comply with cnIkant moOtto ts,ree,,,,iiort tor sit EN:iv:sr.',Erwrgs,Crttern‘notabotons, X2-1Q-AMI.240-4((EEE 1 S47.:2018) IEEE 1547:2,01E3 rUL 1741-SB,37~"Ed) Ethernet 48110nail,IEEE.802,1,CatSE ter Cal6)UTP Etr/Venri cab+e tclodat” COMPLIANCE O Compliance,nnointsiner CA Rule 2.1(1(t.17411A) IEEE 15471010,IA,1741-S8,)',Ed.(11.24Q-Alat,240,4 and X7-11)-001-240-41c1 CAN eCSA C32.2 No,1071,Title 47 CFR,Pert 1.5.Ci1itzS,ICES OCra USTEll Production metering.ANSI C12,;t1 aocurecy Hass 3,5.(Ps'production) e, EN PHASE r;.MPtar,C.1t,to c*enewary Conarenprion'metering,accuracy date 7 III b(te.01-1 itC..AFLIISA-tt 2 2 iitc ova,' To learn more about Enphase offerings,visit enphamcom SHEET NAME tO-C-4-4COS0102.-EN-US-12-21(-2.022 ,,-,s,,,,,,t ,:::-:;k-,,, o..v,..,,,a,' C,.',.,,',';'4'.,,,r..,7.,.,,s',r,,:.4'7,,;,,,, 10-C-4-4C-DS,0133-EN-US--12-29,2022 SPEC SHEETS REVISION: PAGE NUMBER: 0 SS • LUE RAVEN 1403 N.Research Way Orem,UT 84097 800.377.4480 WIRING DIAGRAMS WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION 7.25 .28 DIA NOT FUSIBLE HEREIN CONTAINED SHALL NOT BE FOR THEOF I [184] [1 USED BLUE RAVENIT SOLAR NOR _ (3 HOLES) _ SHALL IT BE DISCLOSED IN WHOLE OR MINIMIEVAIM !_ IN PART TO OTHERS OUTSIDE ? ? I ? ? RECIPIENTS ORGANIZATION,EXCEPT .0 - 11 t-tt IN CONNECTION WITH THE SALE AND . I A II B USE OF THE RESPECTIVE EQUIPMENT, ` II WITHOUT THE WRITTEN PERMISSION �- , II I OF BLUE RAVEN SOLAR LLC. 6.00 Ikill 9.63 [ ] NABCEP [152] , TERMINAL LUGS$ CERTIFIED AMPERES MAX. WIRE MIN. WIRE TYPE A,B,C PV INSTALLATION ,,'-=��� KNOCKOUTS 60 2 AWG14 AWG CU PROFESSIONAL Scott GurneyI e A,B,C _ #PV-011719-015866 IL KNOCKOUTS KNOCKOUTS CONTRACTOR: 4.50 1 3.75 SYMBOL A B C D BRS FIELD OPS [114] [95] 385-498-6700 CONDUIT SIZE .50 .75 1 1.25 7.75 NEMA TYPE 3R [197] 1 0 A,B,C MININIIMIIM KNOCKOUTS C ) <<j 0 �l DUAL DIMENSIONS: INCHES MILUMETERS A,B,C,D KNOCKOUTS HORSEPOWER RATINGS CATALOG WIRING 240VAC NUMBER VOLTAGE RATINGS DIAG. MAX 10 30 DU222RB 240VAC A 10 — DRAWING BY: NOTES: DU322RB 240VAC B 10 15 FINISH — GRAY BAKED ENAMEL UL LISTED — FILE E-2875 SUITABLE FOR USE AS SERVICE EQUIPMENT PLOT DATE: TOP OF NEMA TYPE 3R SWITCHES HAVE PROVISIONS FOR MAXIMUM 2 1/2" BOLT—ON HUB. GENERAL DUTY SAFETY SWITCHES ri SQUARE n SHORT CIRCUIT CURRENT RATINGS: VISIBLE BLADE TYPE 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES 60 AMPERE Schneider Electric 100,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FUSES. ENCLOSURE — NEMA TYPE 3R RAINPROOF PROJECT NUMBER: * LUGS SUITABLE FOR 60'C OR 75*C COPPER OR ALUMINUM CONDUCTORS. NO. 1 861 DECEMBER 2004 REF DWG #1861 SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: SS NINIjoirY RSTC Enterprises, Inc. BLUERAVEN 2214 Heimstead Road E 3 47 K 1 Eau Claire, 1403 N.Research Way i r W 15 03 UT 84097 715-830-9997 FLASHED PV ROOF-MOUNT 800.377.4480 CO. B NER/ENCL URES WWW.BLUERAVENSOLAR.COM (rj� G '�wr 14Frw7 CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE I USED FOR THE BENEFIT OF ANYONE Outdoor Photovoltaic Enclosures 0799 Series EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT Composition/Cedar Roof System IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, ' ' WITHOUT THE WRITTEN PERMISSION ETL listed and labeled w OF BLUE RAVEN SOLAR LLC. ... Report#3171411 PRT-002 Revised May, 2018 {, r CEP • UL50 Type 3R, 11 Edition Electrical equipment enclosures CERTIFIED • CSA C22.2 No. 290 Nema Type 3R -' ` "Asir- PV INSTALLATION • Conforms to UL 1741 Standard ,. ,, 41 PROFESSIONAL {n Scott Gurney #PV-011719-015866 1 0799 Series Includes: CONTRACTOR: £olaDedc 0799 2S BRS D OPS 0799 -2 Wire size 2/0-14 4 385-498-6700 0799 -5 Wire size 14-6 0799 -D Wire size 14-8 Models available in trey,Black or 9ainless9eel Basic Specifications Material options: - ri • Powder coated, 18 gauge galvanized 90 steel (1,100 hours salt spray) y. • Stainless steel S9laDed<0799 6G Process -Seamless draw (stamped) Flashing -15.25" x 17.25" Height -3" Cavity -255 Cubic inches DRAWING BY: Base Plate: Fastened to base using toggle fastening system • r. a; PLOT DATE: • 5 roof deck knockouts • Knockout sizes: (3) .5", (1) .75" and (1) 1" • 8", 35mm slotted din rail „ : PROJECT NUMBER: • Ground Block .11 Passthrough and combiner kits are available for either SDIaDedc0799-DG SHEET NAME. AC or DC applications. SPEC SHEET REVISION: PAGE NUMBER: ---- SS Nier . BLUE RAVEN 1 SFM INFINITY .:: U N I RAC . 1403 N.Research Way W4 OUT84097 , ., � y BETTER SOLAR STARTS HERE Orem, ' z 800.377.4480 4 5WWW.BLUERAVENSOLAR.COM 1 CONFIDENTIAL-THE INFORMATION - HEREIN CONTAINED SHALL NOT BE SHALL USED FITORBE THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR 2 INO WHOLE OR 3 ^U `r ,. IN PART TO OTHERS OUTSIDE ■■ �r K RECIPIENTS ORGANIZATION EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, , ii\I Illt\C 1fHOUT THE WRITTEN PERMISION , SYSTEM OVERVIEW 20% FEWER ATTACHMENTS WIT OF BLUE RAVEN SOLAR LLC. 411„ PART NAME DESCRIPTION Save time and money on every project:SFM INFINITY requires fewer attachments than rail systems. NABCEP ir2 INSTALLS PER DAY TRIMRAIL Structural front trim provides aesthetic and aligns modules. CERTIFIED Make two installs per day your new standard.SFM INFINITY has fewer Qfitf ,p ; °' PV INSTALLATION 1 roof attachments,one tool installation,and pre-assembled components TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAILWe -' 411 PROFESSIONAL Scott Gurney to get you off the roof 40%faster, a , ;, ¢ #PV-011719-015866 �I� � TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof.Available for comp shingle or tile. ri '.A CONTRACTOR: OF HOMEOWNERSII BRS FIELD OPS fill SFM INFINITY 15 Attachments 385-498-6700 a M • P Blir MODULE CLIPS Secure modules to TRIMRAIL. ➢` of i 'y ' 3 v6a" '- 5� j 7 A. MICRORAIL Connects modules to SLIDERS.Provides post-install array leveling. BETTER AESTHETICS I ;� n ' t'-: ZOOM Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east-west bonding. : r ATTACHED SPLICE also available. with integrated front trim,trim end caps,dark components,and recessed hardware. III 11111110. SLIDER FLASHKIT Roof attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES With fewer SKUs and compact components,SFM INFINITY is easier to attachments required by rail. stock,easier to transport,and easier to lift to the roof.Plus,make more PART NAME DESCRIPTION efficient use of your vehicle fleet. irTRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. 4 'fir TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules 0 , .' ' Pal Plil lir N/S BONDING CLAMP Electrically bonds rows of modules ill ID IP all DRAWING BY: PLOT DATE: SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, PROJECT NUMBER: FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: SS MS : SUN . SYSTEM BONDING & GROUNDING : BLUE RAVEN 11111 : S FM FRAME 3 N.Research Way IBM MICRORAILTM INSTALLATION GUIDE : PAGE 140°aoo3»: o W W W.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE �am USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR ...ars.,,;,,,.., SHALL IT BE DISCLOSED IN WHOLE OR .- IN PART TO OTHERS OUTSIDE E o RECIPIENTS ORGANIZATION,EXCEPT 4' IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, i WITHOUT THE WRITTEN PERMISSION I � OF BLUE RAVEN SOLAR LLC. II 4 s:� ter,. XIABCEP OM CERTIFIED BM PV INSTALLATION IMINEEMI o PROFESSIONAL Scott Gurney 1 f min #PV-011719-015866 .. .. u.� E-W BONDING PATH: CONTRACTOR: 1111 E-W module to module bonding is accomplished BRS FIELD OPS with 2 pre-installed bonding pins which engage 385-498-6700 1 rdi on the secure side of the MicrorailTM and splice. 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 ( 1 1 1 1 1 1 1 I I I Star Washer is WEBLUG Single Use Only Single Use Only �ALternate method N-S BONDING PATH: TERMINAL TORQUE, N-S module to module bonding is Install conductor and accomplished with bonding clamp with 2 integral torque to the following: TERMINALTORQUE, TERMINAL TO UE bonding pins. (refer also to alternate method) 4-6 AVVG: 35in-lbs Instal' Conductor and Install Conductor and 8 AWG: 25 in-16s torque to the following: torque to the following: 10-14 AWG: 20 in-lbs 4-14 AWG: 35in-Ibs 6-14 AWG: 7ft-Ibs DRAWING BY: LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO i ',y' �'� r I I SCO Lay-I n Lug (GBL 4DBT) I I Sco Range Lug (SCE-4) Wiley WEEBLug (6.7) IL 1 ��, t-- PLOT DATE: • 10-32 mounting hardware • 1/4" mounting hardware • 1/4" mounting hardware _ ! `' ., Torque = 5 ft-lb • Torque = 75 in-lb • Torque = 10 ft-lb I ALternate method • PROJECT NUMBER: • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded • AWG 6-14-Solid or Stranded _____ ______.a TRI M RAI L BONDING PATH: NOTE: ISOLATE PP EfI FROM ALUMINUM NTACTTO PREVENT ODRROSION Trimrail to module bonding is accomplished with SHEET NAME: System bonding is accomplished through modules.System grounding accomplished by attaching bonding clamp with integral bonding pin and SPEC SHEET a ground lug to any module at a location on the module specified by the module manufacturer. bonding T-bolt. (refer also to alternate method) REVISION: PAGE NUMBER: SS isFMSFRUANMEBLUE RAVEN I ■■ MICRORAILTM INSTALLATION GUIDE ; PAGE 140�N.UT84097vay 800.377.4480 W W W.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION SYSTEM LEVEL ARE CLASSI F1G4TI ON HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR The system fire class rating requires installation in the manner specified in the performance is inherent in the SFM design,and no additional mitigation measures SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE SUNFRAME MICRORAIL(SFM) Installation Guide.SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM.SUNFRAME MICRORAILmcomponents shall OF BLUE RAVENSOLARLLC. B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 modules.Class A, B & C system level fire NABCE� CERTIFIED Module Type Fbof Sope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required PV INSTALLATION PROFESSIONAL Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Faquired Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS UL2703 TEST MODULES 385-498-6700 See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF/ 5400 Pa b) Upward Pressure - 50 PSF / 2400 Pa c) Down-Slope Load - 21.6 PSF/ 1034 Pa • Tested Loads: a) Downward Pressure - 170 PSF/ 8000 Pa b) Upward Pressure - 75 PSF/ 3500 Pa c) Down-Slope Load - 32.4 PSF / 1550 Pa • Maximum Span = 6ft DRAWING BY: • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703,certified to LTR AE-001-2012 PLOT DATE: • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information PROJECT NUMBER: • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: SS 1 ass : F 1 m 1. , . , SUN 1 BLUE RAVEN S FRAME 1 1403 N.Research Way a. ' MICRORAILTM INSTALLATION GUIDE : PAGE °800377.44887 W W W.BLUERAV ENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED Manufacture Module Model I Series Manufacture Module Model I Series Manufacture Module Model I Series EXCCEPPTT BLUE THE BENEFITRAVEN ETOLANNORE SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE Aleo P-Series Eco Solargy Orion 1000& Apollo 1000 LGxxxN2T-A4 RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND LGxxx(A1C/E 1C/E 1 K/N 1C/N 1 K/N 2T/N 2W/ USE OF THE RESPECTIVE EQUIPMENT, ET Solar ET M67ZBHXXXTW WITHOUT THE WRITTEN PERMISSION DNA-120-(BF/MF)26 Q1C/Q1K/S1C/S2W)-A5 OF BLUE RAVEN SOLAR LLC. Aptos Freedom Forever FF-MP-BBB-370 DNA-144-(BF/MF)26 LGxxxN2T B5 FreeVolt Mono PEEK CARCEP LGxxxN1 K B6 CHSM6612P,,CHSM6612P/HV,CHSM6612M, CAL GCL-P6& QCL M6 Series LGxxx(A1C/M1C/M1K/N1C/N1K/Q1C/Q1K/ CERTIFIED Astronergy CHSM6612M/HV,CHSM6610M (BL)(BF)/(HF), TD-AN3,TD-AN4,Hansol LG Electronics QAC/QAK)-A6 PV INSTALLATION CHSM72M-HC UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W)-E6 PROFESSIONAL Scott Gurney AXN6M610T,AXN6P610T, 36M,60M,60P,72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 #PV-011719-015866 Auxi n AXN6M612T&AXN6P612T Heliene 144HC M6 MonofaciaV Bifacial Series, LGxxxN2T-1 CONTRACTOR: AXlblackpremium 60(35mm), 144HC M10 SL Bifacial LGxxx(N1K/N1W/N2T/N2W)-L5 BRS FIELD OPS AXI power 60(35mm), HT60-156(M)(N DV)(-F), LGxxx(N1C/Q1C/Q1K)-N5 385-498-6700 HT Solar Axitec AXlpower 72 (40mm), HT 72-156(M/P) LGxxx(N1C/N1K/N2W/Q1C/Q1K)-V5 AXlpremium 60(35mm), KG,MG,TG,RI,RG,TI,MI,HI & KI Series LR4-60(H IB/H I H/HPB/H PH)-xxxM Hyundai AXlpremium 72 (40mm). HiA-SuocHG LR4-72(HIH/HPH)-xxxM BVM6610, ITEK iT,iT-HE & iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM (30mm) Boviet BVM6612 LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) Japan Solar .PS-60& ,PS-72 Series BYD P6K& MHK 36 Series LONG LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) JAP6 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) CS1(H/K/U/Y)-MS xxx,JAP6(k)-72-xxx/4BB,JAP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM CS3(K/L/U),CS3K-MB-AG,CS3K-(MS/P) JAP6(k)-60-xxx/4BB,JAP6OSYY-xxx/ZZ, (35mm) Canadian Solar CS3N-MS,CS3U-MB-AG,CS3U-(MS/P),CS3W J4Solar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm) CSSA-M,CS6(K/U),CS6K-(M/P),CS6K-MS JAM6(k)-60-xxx/ZZ,JAM6OSYY-xxx/ZZ. Mission Solar Energy MSE Series CS6P-(M/P),CS6U-(M/P),CS6V-M,CS6X-P i.YY:01,02,03,09,10 Centrosolar America GSeries& E-Series ii.ZZ:SC,PR,BP,HiT,IB,MW,MR Mitsubishi M,E& MLE Series CT2XXMxx-01,CT2xxPxx-01, J(M& J<MSSeries Neo Solar Power Co. D6M & D6P Series CertainTeed CTxxxMxx-02,CTxxxM-03, Jinko Eagle J(MxxxM DRAWING BY: CTxxxMxx-04,CTxxxHC11-04 JKMxxxM-72HL-V Dehui DH-60M _Kyocera KU Series PLOT DATE: PROJECT NUMBER: • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Stashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID SHEET NAME: • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM SPEC SHEET • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section,page 12 for further information REVISION: PAGE NUMBER: Ss t , t ._ . ••u : SUN ' . BLUE AVENI p� ■ ' ICRORAILTM I Orem UT84097INSTALLATION GUIQE PAGE 800.377.4480 W W W.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE Manufacture Module Model/ Series Manufacture Module Model/ Series Manufacture Module Model/ Series USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE EVPVxxx(H/K/PK), TwinPeak Series A-Series A400-BLK,SPR-MAX3-XXX-R, RECIPIENTS ORGANIZATION,EXCEPT SunPbwer IN CONNECTION WITH THE SALE AND VBHNxxxSA15 & SA16, TwinPeak 2 Series X-Series,E-Series & P-Series USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION VBHNxxxSA17& SA18, TwinPeak 2 BLK2 Series Suntech STP,STPXXXS-B60/Wnhb OF BLUE RAVEN SOLAR LLC. REC(cont.) Panasonic VBHNxxxSA17(E/G) & SA18E, TwinPeak 2S(M)72(XV) TP572,TP596,TP654,TP660, VBHNXXXKA01 & KA03 & KA04 Twine Talesun eak 3 Series(38mm) TP672,Hipor M,Smart NAtCEP VBHNxxxZA01,VBHNxxxZA02, TP4(Black) SC,SC B,SC 61,SC B2 CERTIFIED VBHNxxxZA03,VBHNxxxZA04 FFnesola Vitrus2 Series & 156 Series Tesla TxxxH,TxxxS PV INSTALLATION Peimar SGxxxM(FB/BF) Risen RSM72 6 (MDG)(M),RSM60 6 PROFESSIONAL PA05,PD05,DD05,DE06,DD06,PE06, Scott Gurney #PV-011719-015866 Phono Solar PS-60,PS-72 SEG Solar SEG-xxx-BMD-HV Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Prism Solar P72 Series S-Energy SN72 & SN60 Series(40mm) PE15H CONTRACTOR: BRS FIELD OPS Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) Seraphim SEG-6& SRP-6 Series UP-MxxxP(-B Upsolar )' 385-498-6700 Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Sharp NU-SA& NU- Series UP-MxxxM(-B) Q.PEAK DUO BLK-G6+ SLA, SLG,BC Series & SlLxxx(BL/NL/NT/HL/ D7MxxxH7A,D7 M( /K)xxxH8A Silfab Q.PEAK DUO BLK-G6+/TS ML/BK/NX/NU/HC) URE FAKxxx(C8G/E8G),FAMxxxE7G-BB Q.PEAK DUO(BLK)-G8(+) Solarever USA SE-166.83-xxxM-120N Solarever BB) Q.Cells Q.PEAK DUO L-G8.3/BFF PowerXT-xxxR-(AC/PD/BD) Eldora, Q.PEAK DUO(BLK)ML-G9(+) Vikram Solivo, Solaria PowerXT-xxxC-PD Q.PEAK DUO XL-G9/G9.2/G9.3 PowerXT xxxR PM (AC) Somera Q.PEAK DUO(BLK)ML-G10(+) VUaaree AC& Adiya Series Q.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Sol arVVorld Sunmodule Protect, Y Sunmodule Plus Winaico WST& WSPSeries Alpha(72)(Black)(Pure) Yn II N-Peak(Black) SS-M-360 to 390 Series, 9 i YGE& YLM Series N-Peak 2 (Black) SS-M-390 to 400 Series, ZN Shine ZXM6-72, ZXM6-NH144-166_2094 REC Sonali SS-M-440 to 460 Series, PEAK Energy Series PEAK Energy BLK2 Series SS-M-430 to 460 BiFacial Series, SS 230-265 PEAK Energy 72 Series SUnEdison F-Series,R-Series & FLEX FXS Series DRAWING BY: Suniva MV Series & Optimus Series PLOT DATE: PROJECT NUMBER: • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID SHEET NAME: • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM SPEC SHEET • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section,page 12 for further information REVISION: PAGE NUMBER: ---- SS , , . ,, in' (//�ll�� AUTHORIZATION TO MARK intertek AUTHORIZATION TO MARK L RAVEN 1r 1403 N.Research Way Total Total tY Orem,UT 84097 This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) ' This authorizes the application of the Certification Marks shown below to the models described in the Product(s) 800.377.4480 pp pp Mark(s) WWW.BLUERAVENSOLAR.COM Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing HEREIN CONFIDENTIAL-THE ISHALL NOT BE NFORMATION Report. Report. US D FOROTHEABENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR This document is the property of Intertek TestingServices and is not transferable. The certification mark(s) maybe This document is the property of Intertek TestingServices and is not transferable. The certification mark(s) may be SHALL IT BE DISCLOSED IN WHOLE OR p p y p p Y IN PART TO OTHERS OUTSIDE applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION Applicant: Unirac, Inc Manufacturer: Redacted information Applicant: Unirac, Inc Manufacturer: Redacted information OF BLUE RAVEN SOLAR LLC. Address: 1411 Broadway Blvd NE 1411 Broadway Blvd NE NABCEP Albuquerque, NM 87102 Address: Albuquerque, NM 87102 CERTIFIED Country: USA Country: USA PV INSTALLATION Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer PROFESSIONAL Report Issuing Office: Intertek Testing Services NA, Inc.j Lake Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc. Lake Forest, CA Scott Gurney #PV-011719-015866 Control Number: 5003705 Authorized by: j(� �lbA (�J` Control Number: 5014989 Authorized by: +z i for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager CONTRACTOR: BRS FIELD OPS 385-498-6700 C US C(1).. Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights,IL 60005 545 East Algonquin Road,Arlington Heights,IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] Standard(s): (s); PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 DRAWING BY: Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM PLOT DATE: PROJECT NUMBER: SHEET NAME: ATM for Report 102393982LAX-002 Page 1 of 4 ATM Issued:27-Oct-2022 ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued:27-Oct-2022 SPEC SHEET ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory REVISION: PAGE NUMBER: ---- SS , .. • , intc4rtcak AUTHORIZATION TO MARK WitC4ftekAUTHORIZATION TO MARK LUE RAVEN Total Waft.&sowed. T 'Assure& 1403 N.Research Way Orem,UT 84097 This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) , This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) 800.377.4480 11 y Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing www.BLUERAVENsoLr+R.coM Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing CONFIDENTIAL-THE INFORMATION Report. Report. HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be SHALL IT BE DISCLOSED IN WHOLE OR applied onlyat the location of the PartyAuthorized To Apply Mark. applied onlyat the location of the PartyAuthorized To Apply Mark. IN PART TO OTHERS OUTSIDE PPpp Y PP PP Y RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, Applicant: Unirac, IncWITHOUT THE WRITTEN PERMISSION PP Manufacturer: Redacted information Applicant: Unirac, Inc Manufacturer: Redacted information OF BLUE RAVEN SOLAR LLC. Address: 1411 Broadway Blvd NE Address: 1411 Broadway Blvd NE NABCEP Albuquerque, NM 87102 Albuquerque, NM 87102 Country: USA Country: USA CERTIFIED PV INSTALLATION Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer PROFESSIONAL Report Issuing Office: Intertek Testing Services NA, Inc., La - Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Scott Gurney Control Number: 5019851 Authorized by: " ' Control Number: 5021866 Authorized by: 'i #PV-01 171 9-01 5866 for L. Matthew Snyder, Certification Manager for L. atthew Snyder, Certification Manager CONTRACTOR: BRS FIELD OPS 385-498-6700 C US COS Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the I agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights,IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard s ; Flat- Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] ( ) Standard(s): PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 DRAWING BY: Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM PLOT DATE: PROJECT NUMBER: SHEET NAME: ATM for Report 102393982LAX-002 Page 3 of 4 ATM Issued:27-Oct-2022 ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued:27-Oct-2022 SPEC SHEET ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory REVISION: PAGE NUMBER: SS '4INtea- • � r kListing Constructional Data Report (CDR) tnt t Listing Constructional Data Report (CDR) L RAVEN N Teal Quality,Assorted. Total Quality,Assured. 1403 N.Research Way r p 3 a Orem,UT 84097 r r yr,.'d e•.. :r' r f�' :% ri ..,t` ,.x'„ N'''. 1 ,;:j e ,PVI,, na ', "sa r' ,' r a- r s d t �r`;,� zJ J,:�;,,..F,..; r ,s,;, ,'.� ,d' .� r„' :� �` .:.?�t F .� ,�Ffi r r'�,.�:r. ,��.:' y..; �:.: ;r` At .oxt, i. ,ee� „..e, ".zw :1':::` --;%°.`%.?fi, %i. _ f:%' Rf=rr�i _ w `»d9 ,-/ .� w' )lavb:,w.' .<)e,`" �f :a. w .`." ,.-x€,.,`J<,��, N.•_ cif:.F6' 800.377.4480 f11'.7 '�'" 102393982LAX-0o2 I Original 11-Apr-2016 I Revised: 5-Oct-2022 102393982LAx-002 Original 11-A•r-2016 Revised: 5-Oct-2022 WWW.BLUERAVENSOLAR.COM ' s �rt r r, ,�y CONFIDENTIAL-THE INFORMATION : - ' ` Mounting Systems, Mounting Devices,Clamping/Retention Devices, and Ground Lugs for Use ' s4..••,, HEREIN CONTAINED SHALL NOT BE r with Flat-Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1-FR:24Mar2021] USED FOR BLUEUE RAVENEIT OF ANYONE EXCEPT SOLAR NOR r ,, ' .1; ; 7, SHALL IT BE DISCLOSED IN WHOLE OR „rix,; ;y, IN PART TO OTHERS OUTSIDE , -, PV Module and Panel RackingMountingSystem and Accessories[CSA TIL No.A-40:2020 RECIPIENTS ORGANIZATION,EXCEPT „ ',' y ] IN CONNECTION WITH THE SALE AND p. /`r. r' ;;,r f rrt ; OFTSPECTIE EQUIPMENT. b , Unirac, Inc • F r WITHOUTTHE WRITTEN ON OF BLUE RAVEN SOLAR LLC. t NABCEP �,�Qa .lr ef,, vie.,„v.:, ! - CERTIFIED �4* F Klaus Nicolaedis Todd Ganshaw PV INSTALLATION PROFESSIONAL ,,f,J 505-462-2190 Scott Gurney A �'� 4,' 505-843-1418 -4' -5' #PV-011719-015866 w NA irt CONTRACTOR: BRS FIELD OPS klaus.nicolaedis C�uniraacom r; '. RS FIELD OP ' toddg@unirac.com g 00 rfr ` 1 , i 't d:.. /,; ' 6 as i 8 �� y'r.;,J :''', y'/y J 'rl1/ r x. fig`/ , DRAWING BY: or irAY.fr e, a �i PLOT DATE: PROJECT NUMBER: Page 1_of 138 Page 2 of 138 SHEET NAME: This report is for the exclusive use of kttertetrs Client and a provided purstseM W the aigreenoti t between Intenai and its Client. Interfere*resporst i y and This morn st t>x the muses uke of katestW*Client and is pn+a'ided pursuart4 10 the egaernteei Wesson lobtrbek sad ifs Clem inftetetr•s rfepone+tsety aid katerity are limited to the terms and oanObons of the agreement. lnlsct it assumes no tiab+i ty to any party_other than to the Client In accordance witty the k1Ciety are limited to the terms and coeatexts of the agreement tntsrtNk assumes no tiabilay to any party,other than to the Ca**in acc rd nce with the SPEC SHEET agreement Sr any loss.*Verse"or damage occasioned by the use of this report Only the Gee**authorized to permit or issbtbution of this rt>port and agreement liar any loss,aitpanse x damage occasioned by the use of this report Only the Caea is authorized to permit copying Or di#>#Xdion of Uri report and them only in its entirety,My use of the Wetter name or one of its marks for the sate or adze tisernent of the teased materiat,product or service roust hest be thin only in its enEreety.Any use of the katertt k name or one 7f C!marts?ot the sate or advertisemarn of the*SW eraalerial,product or service rriut2 treat be approved in wrath,by kitertek.The obsenatedna and teat results on this report are relevant only to the sample tested This report by*sell does not imply that the approved in writing by fntanek_The otiservaoons and test results in this report are relevant only to the sample tested This report by itself Ones not imply that the REVISION: PAGE NUMBER: materiel,product or service a or has ever been under en tntertes ie are:aeon program metersat,product,or service rs or has ever been under an trdertek certification program. ____ SS Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-Apr-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-Apr-2016 11111Ner , ,. Unirac, Inc Revised: 5-Oct-2022 Unirac, Inc Revised: 5-Oct-2022 BLUE #( /�* .' .:v;' ua,ek t,,�.,,i r=, .�x;`!. # .- aA p.vo , M: '" Wirpf M/7�w V Fw,F RAVEN a Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 r � Unirac SFM 1403 N.Research Way I=" Unirac NA Orem,UT 134097 ,s- .� z F``': s i 800.377.4480 ., The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic f},,� WWW.BLUERAVENSOLAR.COM ; Fuse Rating:,„ Rack Mounting System.This system is designed to provide bonding and grounding to � 30A CONFIDENTIAL-THE INFORMATION r ,photovoltaic modules.The mounting system employs anodized or mill finish aluminum brackets HEREIN CONTAINED SHALL NOT BE y USED FOR THE BENEFIT OF ANYONE that are roof mounted usingthe slider, outlined in section 4 of this report.There are no rails Module Orientation: Portrait or Landscape fi i P EXCEPT BLUE RAVEN SOLAR NOR { " yJ • fs 2 SHALL IT BE DISCLOSED IN WHOLE OR -:within this product, whereas the 3" Micro Rail, Floating Splice, and 9 Attached Splice %, ' f Maximum Module Size: 17.98 ft IN PART TO OTHERS OUTSIDE 3 electricallybond the modules together formingthepath to round. re,;0144 'l " UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope RECIPIENTS ORGANIZATION,EXCEPT 0 9 g 9P P �'VIA:, � `�' Tested Loads-50psf/2400Pa Downward, 50 sf/2400Pa Uplift, 15 sf/720Pa Down Slope IN CONNECTION WITH THE SALE AND PM2.0 M ,f P P PUSE OF THE RESPECTIVE EQUIPMENT, Or', -; The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized fi Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading WITHOUT THE WRITTEN PERMISSION } with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the 'f ' OF BLUE RAVEN SOLAR LLC.fi '• ` ,% Increased size ML test: �• � modules to the bracket.The bonding pin of the Micro Rail when bolted and torqued, penetrate � ��� �; • y. M the anodized coating of the photovoltaic module frame(at bottom flange)to contact the metal, • , s; aximum Module Size:22.3 ft2NABCEP _ v creating a bonded connection from module to module. f UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope xi" ° _ CERTIFIED. : � • LG355S2w-A5 The grounding of the entire system is intended to be in accordance with the latest edition of the 4 ';used for Mechanical Loading test. PV INSTALLATION willop,' 'National Electrical Code, includingNEC 250: Groundingand Bonding, and NEC 690: Solar , 0,, Mounting configuration: Four mountings on each longside ofpanel with the longest span of 24" PROFESSIONAL 9 9 P ,• �, Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the ` UL2703 Design Load Rating:46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope Scott Gurney -revision in effect in the jurisdiction in which the project resides. Any local electrical codes must r• , , f.LG395N2W-A5, #PV-011719-015866 if, 1 LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loadingtest. .40,10,410 be adhered in addition to the national electrical codesii4r4,1kX,**MA .The Grounding Lug is secured to the ,��r���� photovoltaic module,torqued in accordance with the installation manual provided in this dJj %±3 Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" CONTRACTOR: document. 4• :• 2,IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift BRS FIELD OPS di;t % 385-498-6700 Other optional groundingincludes the use of the En phase UL2703 certified groundingsystem,14104.19 ' `;; c; 'fi.{ ;Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 P P Y which requires a minimum of 2 micro-inverters mounted to the same rail, and usingthe same Certifications, &Increase SFM System UL2703 Module Size: {�K �' 'tr�j,. engage cable. Maximum Module Size: 27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward,21.6 PSF Down-Slope .' Jinko Eagle 72HM G5 used for Mechanical Loading test. Jar r • Mountingconfiguration: Four mountings on each longside ofpanel with the longest span of 24" f , 9 9 9 P 40,yMMamzimum module size:21.86 ft2 zf r IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift ef ,, , �, ,, . SunPower model SPR-A430-COM-MLSD used for Mechanical Loading r, r ,I i, � Fire Class Resistance Rating: Ng f t ,, ' rV -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any i`; r ,rf f ;,,� interstitial gap. Installations must include Trim Rail. . ,:ate', -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any y , '°,, interstitial gap. Installations must include Trim Rail. a `% '` 4,,A4c -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. r"'r r 4,€ff This system was evaluated with a 5"gap between the bottom of the module and the roof's , r f 4 % surface f� �T4rf, See section 7.0 illustractions# 1, 1 a and lb for a complete list of PV modules evaluated with DRAWING BY: ,,,, 0.0these racking systems rss 0'0_7���V <. . "00-0, PLOT DATE: P NA PROJECT NUMBER: SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory __ S S Report No. 102393982LAX-002 Page 42 of 138 Issued: 11-Apr-2016 Report No. 102393982LAX-002 Page 43 of 138 Issued: 11-Apr-2016 - Unirac, Inc Revised: 5-Oc t-2022 2022 Unirac, BLUE RAVEN Inc Revised: 5-Oct-2022 .. ,-. .. ,+s, r v.,,,. G.,. r m+� ..., ,.F ,>. ...,... ,. ,+, .f,..r / d- ,,.FF''/ .' r 4 � ., ,, , ,' , ,. 'F F , -.. "-. ,: a .: , v r , ,:- 1, ` ,..v. .y. .. ...„,. .. ,., ,' :, /�. v �.�. .x` r, � ,. .. ,+ r" ,%un r.. /1 � ,a� c r. � ,w':.. .. ,'/" r, F.. ,., ,...,.. .,.. ,+. s, r v'::' �` F. .F. / vti'/ .5`.. al.,r. .,S'�.".F'!` � ., ����'' ,. + ./J „ �;,. ,. ,+�.f. i �.v d'.,^F .vJ` /�. ... ,r' r� �.! n�.�.rA? . .!�`�.�S` a �'if ,.. �,r'/F � � � ) ,.ter. J' 1. ."A� ..f . ,v �,/`•.. ., ../. P ,.,.. ,.1, f . � ,.�..:. ,�.A.S,.. .� s...r/. v...,»t. ... .. s t� .,, ../ .,.. r .lf s" �'`. „ ..rr`�. �". r� ,'`� s,+:rf./, � � , ,!� �'., I iP t t". ,.. �,.: ,. ./�.. �. .s.. !., f" .vr� .„�"f�''`� P.r f Y� /. . +� ./",'v.� .M,x�''.�'vv n,A�F,.,;.,,,f F ,�',r, ,,.�'.. z,cw::ir,€x- .vw-: <w/. ,,s!'r�d�Fr.�?';.r..�t� /„/%-�.,;�'� ,!`�'�r,`riFa�F�� %y� ,.tF'`,'�.r, ,,.�., �x...., rS�,.�...'-/„,,�..F�.r �,>{r wf.v':..vr..,F.,r������#.,z'�� vFv,,rr�,�, F./,� v.� �u, v x,,.../.,/ �,:o/ , Illustration 1 -Approved PV Modules Illustration la-Approved PV Modules Continue 1403 N.Research Way Orem,UT 84097 800.377.4480 Mestufartaxe MethaW Heed/Series Manafeeterst Madill 7 M ' l4artltterMedet(Series Modukirftiodet(Sestet WWW.BLUERAVENSOLAR.COM ........_._____ _. CONFIDENTIAL-THE INFORMATION Aim P- Et*Seisms , Orion 1 3 to 1 tGtr:+txs71-A4 EVPVses( ). HEREIN CONTAINED SHALL NOT BE 11 .Platt ( 4612 se 100,s t(A1C E1C ilk i111+s 41 41S1T/141W *SAI5 6,5A26.. USED FOR THE BENEFIT OF ANYONE -17i2 - 7EXCEPT BLUE RAVEN SOLAR NOR 1 1 TT 9-37(1 Q1 1 2 -AC xxxSd.17&$,0.18, SHALL IT BE DISCLOSED IN WHOLE OR L t Mons PCP(' 1.6 71-BS P ' xx 17(116)&SAi IN PART TO OTHERS OUTSIDE Cta 1nt04 17H ,C T?M. wit Ltaxxx142X-186 faot3 PA01IL PAM, RECIPIENTS ORGANIZATION,EXCEPT LE AND tsr 00,4400a ,(r1. 1 (6k)(At)ttHri, Tt4.s 3,1tt-attar, troxxA3 C 3Mlx�lrtl+lta3 It 1Ki 1. N 7, IN CONNECTIONRESPECTIVE { -� USE OF THE RESPECTIVE EQUIPMENT, 1 *, i V ;- 4i WITHOUT THE WRITTEN PERMISSION C 1244 , 4)6 aial t7I7-aN1 1t"a t it-W CS OF BLUE RAVEN SOLAR LLC. 'AX 10T,*X -l0T, £rDM, ,UM&UP1eties, LiosstfieiYi`. Mi 7Td°N' -66 5 ixxx!(F AXNCM617T&AXIMPSE2T eittierie 144HCh45 PiorterstieVitiLitte5ertes, SOW PS 60,PC 77 &Sestett a srut�(tt1tss 14 KCA410 saLtLi[fat "ta -)3 Solar " P72ye s NABCEP LLtocti$146aNISSt29il2 LI AX.4ps tver,00(35tett), .... HT60 I ISM NOT)(P'(. KM..Prtt,Pe2tk,Ca3,ta4,Q5,QffrO,L 07, +) CERTIFIED ?t1 Sear t€tatx(N1OVIC 11X)Ns Aviles Ali we+72(9t9n tit, HT 7T'156(1 '1 ,IVA'L-42,L-Cot9- S.L0ta Ltd LCsxxx(tirei +Q�CQit -VI AX a f35a 1txt( KCs MS T fa i, ,It,r»a,tat f Ks. QPIM DUO OL€ , AXttremlum 22 t t e, cii:A.SYx 1 R t at( PH$.xxxbl 1 - PV INSTALLATION L4ta-at14+a*aI - , PROFESSIONAL tY1 12 ITV( .eT,eT4Ef d-tT�9f . - /H ,04 *u (3 4) Q,PTAX MO .F opt.ww two(BLit)' r) a t'SS'0&1PS 72 Scott Gurney )6en O ) ,} 6 4[te PSi(M (4S ) #PV-011719-015866 p }W @/4P#r •xxx,1 xx tAM (7 LONG Litt, yd t t PEAK s :10 Xa,40 t a/ I CONTRACTOR: 1( i°I Lxt,$ wq-p Jf), ' $,IPX2•k °Y Z. 4,4{t}et i)aaaM(.14)))m) c a , 3X-M(4 NI/PI MO(OM M1-610141 BRS FIELD OPS f•k) xxxt I$.t "t Y..01.. L1tS 7a { w TB,mode $PXL Gd2 02f103#1#latid$t0 C.a r t'S31d•1�1S,C'S',Sti-M6 ACi&a3tP-d .4"a3'A' 'IA Sao b )-72 xxx7'12,M)0172SY'd'x.),)12:,. ; 13Stram € e s:.��,e; ,�c,.� �-,� .c .n .. . .,� . ..... .... . .�7 �, _ „ .. ,.._�., _ _...� .. ._, 385-498-6700 r 414lP1.rs 4i•t i rs4V4r1(SA t 1#. .x 1 . t4t r�(Bx4(tt, 1 YxaM a,YT.21,02,93,09,10 s, t:4i1.4 r r sff . MSr N• •4 at< + s., s a tea ti.z :st c a , � €c (T:3x sxx-1)t,C12704'r=rt-01„ Sli &PRI Sei Its • Energy C satrel CT ar.Mra CTx rxR1.03, )KM 8 Ma Series f ter y tlLkta Series i TxxxNtxx' 4,Ctxxxt9$31 Hi** SMttx. i Neel$tB(Af Pester a , tTGM&i4GP PEAK 5rr#rt7y7a�t . _ eft axi v .,.. tricots •.ett DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory __—_ ss Report No. 102393982LAX-002 Page 44 of 138 Issued: 11-Apr-2016 Unirac, Inc Revised: 5-Oct-2022 6 .=rt P a' + e4� 5)pi i� �,'. �.. ,w9P,%- r7�r. 'i $°- ,e` Ewes �, l�a�`. „"+it AOJ' :// A;,:� .f,.� �s 7 " lf:. �` ,:'.. ,t ErF:%''�-sir'f , F�, ,.,. ..�,t';�,.„�1,: Illustration 1 b-Approved PV Modules Continue 1403 N.Research Way rem,UT 84097 800.377.4480 W W W.BLUERAVENSOLAR.COM A See ` CONFIDENTIAL-THE INFORMATION krnr HEREIN CONTAINED SHALL NOT BE 'iv in teak 7 Series x,S.riel E-Selik S A P,?pe % FOR THEOF ?� ,S SE S F E-„ USED EXCEPT BLUE RAVEN T SOLAR NOR Tavrt# ak3S41M)77^ TP5711P"a h,TP6SA,T1%660. SHALL IT BE DISCLOSED IN WHOLE OR To as S . #Slat TP677. IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT TP4(6144TM CSC 8,SC 81.SC 82 IN CONNECTION WITH THE SALE AND legVitt'rt$hra 4 1 S ie$ TAN,1r USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION Mum 1 -6 ) IAA -6 PAM, 5,0 3,Ott n* OF BLUE RAVEN SOLAR LLC. SEL Solar SEG-nxv".. fe466 Kn4.=Pitt 0014,MOM.Ot itMI5, S-lottov 9477 A 5 Wk.%C4 PUSH R& 6&vi x1 , . NABCEP CERTIFIED Sly MA,MG,E44'Srrrlr exxl A Sdia di. 9T*Md1„ 07,4JorAWA,1)7 ,Nto titRA "i v I >.taixx€a . PV INSTALLATION Sotrur'r USA 5`'A '" FANIxx.486688) PROFESSIONAL Eldora, Scott Gurney Warta PP riXT-r wC-t Vikf. » Sol., #PV-c1 t Gurney PowerX -xxzR- a & i3a CONTRACTOR: BRS FIELD OPS ssrsv 385-498-6700 SS.,.r t. p to 400 Seim,. 7N 5h .... . . :TXMfr7I,dXM NN 44464 SoriNi SS-M- to 460. SS-M-450 te 460 Stiatiiti SS I1 76S DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ED 16.3.15(1-Jul-2022)Mandatory S S