Plans (2)
GENERAL NOTES AERIAL VIEW RE rr . �> CODE AND STANDARDS y MAY o 1.ALL WORK SHALL COMPLY WITH 2O17 OREGON ELECTRIC SPECIALTY CODE(OESC),2019 OREGON - �„ STRUCTURAL SPECIALTY CODE,2017 OREGON RESIDENTIAL SPECIALTY CODE,AND ALL STATE AND LOCAL . % CITY O F TIGARD :a.s*..aF :. 441411 BUILDING AND ELECTRICAL CODES. A - 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. F ,a SITE NOTES/OSHA REGULATION p,aarn.. ** Ili,W, ;- Orem, UT 84097 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. +�. s"•,. 800.377.4480 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. "1P'' R W W WENTIAL THE IN LAR.COM 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. t 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE ANDr+irk 0r : *iA CONFIDENTIAL-THE INFORMATION THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT 1r �, HEREIN CONTAINED SHALL NOT BE THE BUILDING OR STRUCTURE. USED FOR THE BENEFIT OF ANYONE i .. Ly if. , • '�i q EXCEPT BLUE RAVEN SOLAR NOR SOLAR CONTRACTOR OFFICE COPY * # ¢ � SHALL IT BE DISCLOSED IN WHOLE OR - IN PART TO OTHERS OUTSIDE 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. z`4 „ RECIPIENTS ORGANIZATION,EXCEPT 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER — .ww ' ' • a r IN CONNECTION WITH THE SALE AND THE MANUFACTURER'S INSTALLATION REQUIREMENTS. ., 7w, r.a A. } USE OF THE RESPECTIVE EQUIPMENT, 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF ' •'' `.` r ♦ WITHOUT THE WRITTEN PERMISSION STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. OF BLUE RAVEN SOLAR LLC. MI #`. 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO E 11 N " e ,•, S 1 f , LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. y.„ • ,::: z 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A "d a 4 #ir N h P SUITABLE SEALING COMPOUND. - r ABC E 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. m+ + 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. CERTIFIED 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT �"�+�. AVAILABLE. ..� - '" ' Z PV INSTALLATION 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC _ z- 44, '` ..,,.: "°"'�""° 11 • PROFESSIONAL_ a PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND ` # Scott Gurney CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND ! $ Y 1 {. #PV-011719-015866 LISTED FOR THE APPLICATION PER NEC 690.4(B). t 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. CONTRACTOR: 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) #103111. 4 "" L.. s z" IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. "- BRS FIELD OPS x "i` 800-377-4480 EQUIPMENT LOCATIONS r �. * :;1i • 1.PROPER +r ACCESS ..AND WORKING CLEARANCE AROUND EXISTING AND PR OPOSED ELECTRICAL EQUIPMENT #t WILL BE PROVIDED AS PER SECTION NEC 110.26. r 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS y SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). r. •x 44 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC *i ,,,,,,, . • * U APPLICABL E CODES. A r .. U 4.ALL COMPO NENTS ARE LISTED a S D FOR THEIR PURPOSE AND ' 'RATED FOR OUTDOOR ,r U DOOR USAGE WHEN APPROPRIATE. O IATE. >x,. �'" i 4, CITY OF TII a,�LD ► ''''''‘4.,. y ; PROJECT INFORMATION._ .. ,,.: M i.. '� a `o o Y 72' �Ir 'g:D I OP. ODE COMPLIANCE ` , Ts �} �} LC CC N NUMBER OF STORIES: 1Aj� ro�Approved: kO . . N W W CONDUIT RUN: Interior , n i� ;,: _. >.',` ; I , .•Y.a f p Cn r N N ECOBEE QTY: 1 0`1.C: [ ] �J hrJ 2 - Z C'3 N LIGHT BULB QTY: 0 Permit #: V' " ( W (/J- O A' , ,... arrrrrrrrr r 6 '� _CD p w N ,/s PV METER: Not Required µ Ad ccss: 4 S S� 1�a PIA Sr DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX w > Y ROOF TYPE(1) INFORMI '�p y:#: ` . fV O N ROOF TYPE: Comp Shingle WIND SPEED: 100 mph CONSTRUCTION -V-B PV1 -COVER SHEET Approved plans H 5_ -2 FRAMING TYPE: M1&F}iifactured Truss ' Date: 2?, Z3 GROUND SNOW LOAD: 40 lb/ft2 ZONING: RESIDENTIAL PV2-SITE PLAN Chall be on job S°#?. N as CO - , WIND EXPOSURE FACTOR: C PV3- ROOF PLAN c) o rn � C.) V SHEATHING TYPE: SKIP V U rn < Cl ATTACHMENT: SFM Infinity Flashkit SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL PV5 ELECTRICAL 3-LINE DIAGRAM DRAWING BY: RACKING: Unirac SFM Infinity 48"OC Portrait/48" OC Landscape NUMBER OF ATTACHMENTS: 36 SCOPE OF WORK PV6 ELECTRICAL CALCULATIONS PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore ROOF TYPE(2)INFORMATION (IF APPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHER SHEETS AS REQUIRED) *SEE PV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SS PRODUCT SPEC. SHEETS PLOT DATE: May 13, 2023 a ' PROJECT NUMBER: SYSTEM TO BE INSTALLED INFORMATION: THE ISSUANCE OF A PERMIT UTILITY COMPANY: DC SYSTEM SIZE: 5.6 kW DC BASED ON CONSTRUCTION . U N7 ?Jr,' Portland General Electric (PGE) 773908 AC SYSTEM SIZE: 4.06 kW AC DOCUMENTS AND OTHER f € r' 0:a SHEET NAME: DATA SHALL NOT PREVENT , MODULE TYPE: (14)QCells Q.PEAK DUO BLK ML-G10+/t 400 THE CODE OFFICIAL FROM PERMIT ISSUER: COVER SHEET INVERTER TYPE: Enphase IQ8PLUS 72 2-US REQUIRING THE CORRECT'ON MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 ° City of Tigard REVISION: PAGE NUMBER: OF ERRORS. ORSC 105.4 0 PV1 / PV SYSTEM SPECIFICATIONS LEGEND TOTAL NUMBER OF MODULES: 14 � JUNCTION BOX MODULE MAKE AND MODEL: ()Cells Q.PEAK DUO BLK ML-G10+/t 400 I , ,„ MODULE WATTAGE: 400W DC �MJ UTILITY METER INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US I 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) I MSP MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC I 800.377.4480 INVERTER NOMINAL VOLTAGE: 240V I 01 AC DISCONNECT WWW.BLUERAVENSOLAR.COM INVERTER WATTAGE: 290W AC I CONFIDENTIAL-THE INFORMATION I CB COMBINER BOX HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE I EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR I LC LOAD CENTER IN PART TO OTHERS OUTSIDE I RECIPIENTS ORGANIZATION,EXCEPT '_ c 1st IN CONNECTION WITH THE SALE AND I USE OF THE RESPECTIVE EQUIPMENT, SUB SUBPANEL WITHOUT THE WRITTEN PERMISSION o OF BLUE RAVEN SOLAR LLC. I �VJ PV METER NABCEP ® ® I TS TRANSFER SWITCH CERTIFIED I ® ® II I PV INSTALLATION oLim ESS : :::::: ::+ I HUB I / CONTRACTOR: / I RPO REMOTE POWER OFF BRS FIELD OPS % NE I illairg 800-377-4480 AEl j I , FIRE SETBACK ITRENCHING C.) I I z II PROPERTY LINE Q I 0 I SCALE: 1/16" = 1'-0" Q a o (.0 cc C ' N I Q al di O N" N N _ ZC'3 � C) Nc� I IW •5 Y N W W I Nc2 � 2 NN I MEarm VV (TS 40 .,...,L DRAWING BY: Brendan Fillmore II PLOT DATE: 1_ May 13, 2023 FRONT OF PROJECT NUMBER: 9945 SW KABLO ST 773908 SHEET NAME: 1. AC DISCONNECT TO BE LOCATED WITHIN 10 FT. OF METER 2. FOR PRESCRIPTIVE INSTALLATIONS, ROOF ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24 IN. OC SITE PLAN IN ANY DIRECTION WHERE LOCATED WITHIN 3 FT. OF A ROOF EDGE, HIP, EAVE, OR RIDGE(OSSC 3111.3.5.3) 3. FOR NON-PRESCRIPTIVE INSTALLATIONS, PLANS WILL BE APPROVED AND STAMPED BY LICENCED REVISION: PAGE NUMBER: ENGINEER AND ALL ATTACHMENT SPACING WILL BE AS SHOWN ON PV4. 0 PV2 PV SYSTEM SPECIFICATIONS LEGEND TOTAL NUMBER OF MODULES: 14 MODULE MAKE AND MODEL: QCells Q.PEAK DUO BLK ML-G10+It 400 JUNCTION BOX MODULE WATTAGE: 400W DCBLUE CM� UTILITY METER R E INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) MSP MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC 800.377.4480 INVERTER NOMINAL VOLTAGE: 240V AC AC DISCONNECT WWIN.BLUERAVENSOLAR.COM INVERTER WATTAGE:290W AC CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE CB COMBINER BOX USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR LOAD CENTER SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE N LC RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, SUB SUBPANEL WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. J PV METER 0 AA-BC-EF'\\\ TS TRANSFER SWITCH CERTIFIED 0 PV INSTALLATION 0 ESS SUNPOWER ESS PROFESSIONAL —1' Scott Gurney #PV-011719-015866 //////////////////////////////4/(/, HUB SUNPOWER HUB+ CONTRACTOR: 011 0,Tll iil MP1 RPO REMOTE POWER OFF BRS HELD OPS i 800-377-4480 #OF MODULES: 11 ril AZIMUTH: 172 g FIRE SETBACK ' PITCH: 19 rm TSRF: 85% I Fli eit r;� AREA: 472 ft.z TRENCHING Z Q Q / 1 PROPERTY LINE r SCALE: 1/8" = 1'-0" co coo / �t 4 6�f 1 POINT OF INTERCONNECTION H N N N ). IMSP rM ` W •c cz N W uj / �__ � 2N O u) N / D . cm V V CB UUrnH QG MP2 DRAWING BY: #OF MODULES: 3 AZIMUTH:82 Brendan Fillmore PITCH: 18 PLOT DATE: TSRF: 75% AREA: 155 ft.2 May 13, 2023 PROJECT NUMBER: FRONT OF HOME 773908 1. AC DISCONNECT TO BE LOCATED WITHIN 10 FT. OF METER SHEET NAME: 2. FOR PRESCRIPTIVE INSTALLATIONS, ROOF ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24 IN. OC IN ROOF PLAN ANY DIRECTION WHERE LOCATED WITHIN 3 FT. OF A ROOF EDGE, HIP, EAVE, OR RIDGE (OSSC 3111.3.5.3) 3. FOR NON-PRESCRIPTIVE INSTALLATIONS, PLANS WILL BE APPROVED AND STAMPED BY LICENCED ENGINEER REVISION: PAGE NUMBER: ' AND ALL ATTACHMENT SPACING WILL BE AS SHOWN ON PV4. 0 PV3 STRUCTURAL INFORMATION: STRUCTURAL NOTES: PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE ROOF TYPE(1): ROOF TYPE: Comp Shingle 1. AC DISCONNECT TO BE LOCATED WITHIN 10 FT. OF METER SHEATHING TYPE: SKIP 2. FOR PRESCRIPTIVE INSTALLATIONS, ROOF ATTACHMENTS BLUE RAVEN ,, FRAMING TYPE: Manufactured Truss SHALL BE SPACED NO GREATER THAN 24 IN.OC IN ANY FRAMING SIZE: 2x4 @ 24"OC DIRECTION WHERE LOCATED WITHIN 3 FT. OF A ROOF EDGE, u N II VC A CEILING JOIST SIZE: 2x4 © 24"OC HIP, EAVE,OR RIDGE (OSSC 3111.3.5.3) 23„ I 1403 N. Research Way 3. FOR NON-PRESCRIPTIVE INSTALLATIONS, PLANS WILL BE MAX. r 48" MAX. LANDSCAPE Orem, UT 84097 ATTACHMENT: SFM Infinity Flashkit APPROVED AND STAMPED BY LICENCED ENGINEER AND ALL 800 377 4480 W W W.BLU ERAVENSOLAR.COM RACKING: Unirac SFM Infinity ATTACHMENT SPACING WILL BE AS SHOWN ON PV4. 48"OC Portrait/48"OC Landscape PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE NUMBER OF ATTACHMENTS: 36 None USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR PV MODULE COUNT: 14 Modules I I SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE TOTAL ARRAY AREA: 285.6 ft2(20.4ft2/panel) 1 RECIPIENTS ORGANIZATION,EXCEPT TOTAL ROOF AREA: 2204 ft2 ' INE O CONNECTION N WITH THE ESALE AND T, ARRAY/ROOF AREA: 13% III 'I X WITHOUT THE WRITTEN PERMISSION ARRAY WEIGHT: 700 lbs (50 lbs/panel) 23 L. 48" MAX. PORTRAIT OF BLUE RAVEN SOLAR LLC. DISTRIBUTED LOAD: 2.45 lbs/ft2 MAX. POINT LOAD: 19.44 lbs/attachment *NOTE:LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY ATTACHMENT SPACING- FRONT VIEW -RACKING ATTACHMENTS TO BE STAGGERED NABCEP BASED ON FIELD CONDITIONS.MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER O ENGINEER OF RECORD SPECIFICATIONS. SCALE: 3/4" = 1'-0" CERTIFIED UNIRAC SFM INFINITY UNIRAC SFM MICRORAIL/SPLICE O PV INSTALLATION PV MODULE 0,0 PROFESSIONAL ��_ -011Scot Gurney QCELLS Q.PEAK DUO BLK ML-G10+/T #PV-011719-015866 400 v' PORTRAIT CONTRACTOR: PV MODULE �- BRS FIELD OPS ®� UNIRAC SFM SLIDER �� - 800-377-4480 ROOF STRUCTURE go (E) ROOF —� MODULE — OO SHEATHING - WIDTH O FLASHING v U (1) 5/16" STAINLESS STEEL LAG BOLT /f//�/f///�/ :///lT�fll v LANDSCAPE WITH 2-1/2" MIN. EMBEDMENT f �- y� H AND FLAT WASHER 2%2" MIN. EMBED. /' �iow_ _ • MODULE 19Io a N u. A MIDDLE/TOP STANDOFF DETAIL ATTACHMENT SPACING- SIDE VIEW z 0 a) °' v) u) SCALE: 3"= 1'-0" (E) BUILDING STRUCTURE D SCALE: 1/2" = 1-0" ccai 0 2 2 W •5Y N WW QCELLS Q.PEAK DUO BLK ML-G10+/T 400 2 N O N N PV MODULE O c>'S .D } > as u7 co co U n VUrnI— CC UNIRAC SFM TRIMRAIL FLASHING DRAWING BY: IF ra Brendan Fillmore UNIRAC SFM SLIDER AND f (E) ROOF TRIMRAIL ROOF ATTACHMENT PLOT DATE: SHEATHING May 13, 2023 (1)5/16" STAINLESS STEEL LAG BOLT //1f1//////1,i////7/1j�� / PROJECT NUMBER: WITH 2-1/2" MIN. EMBEDMENT ? 773908 AND FLAT WASHER ~ 2Y2" MIN. EMBED. SHEET NAME: 6 STRUCTURAL REVISION PAGE NUMBER BOTTOM STANDOFF DETAIL B (E) BUILDING STRUCTURE 0 PV4 SCALE: 3"= 1'-0" (1) 10 AWG1HHN/THWN•2,CU.,TRACK(11) 16,9 A AC 12) 10 AWG THHN/THWN-2,CU,,BLACK(11) MAX 8.6 A AC 41) t0 AWG THHN/THWN-2,Ctl.,BLACK 4111 MAX 8,s A At' 11)12-2 tC-ER,tHHN/THWN•2,CU. MAX TES A AC y c (1) 10 AWG THHN/TIHWN-2,CU.,RED 1L2) 240 V AC 3 12) 10 AWG THHN/THWN•2,Cu,RED 1121 240 V AC *1 111 10 AWG T#!HP4/THWN-2,CU.,RED fill 240 V AC j (1( 6 AWG BARE,CU(EGC) 24d V AC (1) 10 AWG THI4N/TI4WN-2,CU.,WHITE(N) (1) 10 AWG THHN/THWN-2,CU.,GREEN(MCI 44 41) 10 AWGTHHN/THWN-2,CU..GREEN(EGC) 1111111Negi" 1 (1) 10 AWG TMHN/THWN"2,CU.,GREEN(EGO OR 10 2 OF-B W/G(OR NM-B),TTHHN/TNwNC 2,$QUD Cu A INC14 EMT EXTERIOR 4 INCH EMT EXTERIOR 1 3/4 INCH EMT Not RA uirpd Tot UF,1f C►111N1.8 CibtE INTERIOR EXtnUUOR RAVEN (1) 6 AWG TNIiN/TIIWN•2.CU.,BLACK(Li) 1i6,9 A AC BLUE 16 (1) b AWG THHN/THWN-2,CU,,RED(L2) 240 v AC (1) B AWG THHNITHWN-2.CU,WHITE NI 1403 N. Research Way (1) 3/4 INCH EMT txlr1410R Orem, UT 84097 800.37 .44 W W W.BLU ERAV7ENSO80 LAR.COM DESIGNER NOTES: ELECTRICAL NOTES: CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE SUPPLY SIDE TAP.INTERIOR POI ALL CONDUIT TO BE RAN AT LEAST 7/8 IN.ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. USED FOR THE BENEFIT OF ANYONE AC DISCONNECT TO BE LOCATED WITHIN 10 FEET OF THE UTILITY METER. EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE (14)()Cells Q.PEAK DUO BLK ML-G10+/t 400 RECIPIENTS ORGANIZATION,EXCEPT (E)125A MAIN SERVICE PANEL ENPHASE IQ COMBINER 4 UL 1703 COMPLIANT IN CONNECTION WITH THE SALE AND X-IQ-AM1-240-4 (14) Enphase I08PLUS-72-2-US USE OF THE RESPECTIVE EQUIPMENT, (E)125A/2P MAIN BREAKER (SOLAR LOAD ONLY) UL 1741 COMPLIANT WITHOUT THE WRITTEN PERMISSION 4"x4"x4"PVC JB-1 EZ SOLAR OF BLUE RAVEN SOLAR LLC. PV AC DISCONNECT JUNCTION BOX JUNCTION BOX FUSED,AIC 10kA (N)20A/2P L n JB L 1 JB 1 L '� _ _ (1)CIRCUIT OF Li • LOCKABLE,VISIBLE OPEN 2 • 30A,240V,2-POLE L2 z L2 s " ° EGG' EGC' - 7 MODULES A--A-BC-El: ENVO 25A L- ,5 � 6 CERTIFIED (E)LOADS FUSESr 2 N —O PV INSTALLATION z ^ � L12 (N)20A/2P u EGC L, 1 _ _ --O n — ^ JB 1 ^ PROFESSIONAL N —O N L2 L2 1 L2 1 (1) CIRCUIT OF Scott Gurney 111,,\EGC r EGC i _} EGC \�\ 7 MODULES #PV-011719-015866 G I T Y 120/2aovAc N 16 15 __� 3 V (� CONTRACTOR: 60HZ GROUNDS AND v v 1 PHASE BRS FIELD OPS TO UTILITY NEUTRALS BONDED__ 800 377 4480 GRID G (N)6 AWG SOLID COPPER GEC TO BE IRREVERSIBLE SPLICED TO(E)GEC TO COMPLY WITH I _INEC 250.64(D)(1) ., a I � .. z > o _L(E)GROUNDING it O — ELECTRODE(S) � ,, r Q � N .- 4 tr NN �� O N N = - . N W W Cl2V t 3 P • !f id O N (�nI O (n (/) F .. t ° L. • cr 11/--� 2 Lf' -2 �� 5 4 I } � ) MT 1U.200 WV�Y_ 14 'I E1112& 1404, ' rn L Cr)) � V V 1 }4 .'MPfWRbiPMMMYI�MY 'Ar� 11 � 3, V U I— < 0 24Os4 ...I w ( DRAWING BY: .� • ' Brendan Fillmore " 00I0 fi:.. / PLOT DATE . May 13, 2023 PROJECT NUMBER: 773908 INTERCONNECTION NOTES ,, SHEET NAME: 705.11 AN ELECTRIC POWER PRODUCTION SOURCE, WHERE 'c ,, ° ELECTRICAL CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PERMITTED IN 230.82(6), SHALL COMPLY WITH 705.11 (A) REVISION: PAGE NUMBER: THROUGH (E). UTILITY COMPANY: Portland General Electric (PGE) PERMIT ISSUER: City of Tigard 0 PV5 MODULE SPECIFICATIONS QCe1IsQ,PEAKDUOBLKML-G.0+/t400 DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 400 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG.HIGH TEMPS MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 8..5 A AC MODULE VOC 45.35 V DC STATE Oregon, JUNCTION BOX(1) MAX.CURRENT(ISC X1 25)= 10.6 A AC MODULE VMP 38.09 V DC CITY Tigard, CONDUCTOR(TC-ER,COPPER(90 C))= 12 AWG BLUE RAVEN MODULE IMP 10.5 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 11,07 A DC ASHRAE EXTREME LOW TEMP(-C) -6 AMB.TEMP.AMP,CORRECTION= 0.91 VOC CORRECTION 0-27%/'C ASHRAE 2?6 AVG.HIGH TEMP I'Cj 36 ADJLATEDAMP.= 27.3 > 10_6 1403 N. Research Way VMP CORRECTION -0.34%PC JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 8.5 A AC Orem, UT 84097 SERIES FUSE RATING 20 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 OR 2 OR 3 OR 4 CIR 5 CIR 6 JUNCTION BOX(2) MAX.CURRENT(ISC XL25f 10.6 A AC 8ERAVENS 0 I WWW.BLUERAVENSOLAR.COM ADJ.MODULE VOC @ ASHRAE LOW TEMP 49.4 V DC NU ER OF MODULES PER MPPT 7 7 CONDUCTOR(UF-B,COPPER(60'C))= 10 AWG CONFIDENTIAL-THE INFORMATION ADJ.MODULE VMP @ ASHRAE 2%AVG.HIGH TEMP 32.5 V DC DC POWER RATING PER CIRCUIT(STC) 2800 2800 CONDUCTOR RATING= 30 A HEREIN CONTAINED SHALL NOT BE FOR THE BENEFIT OF TOTAL MODULE NUMBER 14 CONDUIT FILL DERATE= 1 USED EXCEPTBLUE RAVEN SOLAR NOR MICROINVERTER SPECIFICATIONS Enphase IQJ3+Microinverters STC RATING OF ARRAY 5600 AMB.TEMP.AMP.CORRECTION= 0.91 SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE POWER POINT TRACKING(MPPT)MIN/MAX 30 - 58 V DC AC CURRENT Z. MAX POWER POINT(IMPS 8.5 8.5 ADJUSTED AMP.= 27,3 > 10.6 RECIPIENTS ORGANIZATION,EXCEPT MAXIMUM INPUT VOLTAGE 60 V DC MAX.CURRENT(IMP X 1.2S) 10.5875 10.5875 JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 8.5 A AC IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 _ 20 COMBINER BOX(3) MAX.CURRENT(ISC X125)= 10.610.6A AC WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. MAXIMUM USABLE DC INPUT POWER 440 W MAX.COMB.ARRAY AC CURRENT(IMP) 16.9 CONDUCTOR(UF-8,COPPER(60'C))= 10 AWG MAXIMUM OUTPUT CURRENT 1.21 A AC MAX.ARRAY AC POWER 4060W AC CONDUCTOR RATING 30 A AC OVERCURRENT PROTECTION 20 A CONDUIT FILL DEBATE= 0.8 N A BC E P MAXIMUM OUTPUT POWER 290 W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. /RISE(V) VEND(V) %VRISE AMB.TEMP.AMP.CORRECTION= 0.91 CERTIFIED CEC WEIGHTED EFFICIENCY 97% VRISE SEC. 1(MICRO TO JBOX) 25.2 12 Cu. 0.71 240.71 0.30% ADJUSTED AMP.= 21.84 > 10.6 VRISE SEC,2(JBOX TO COMBINER BOX) 40 10 Cu, 0.• 240.;•. Q36% COMBINER BOX TO INVERTER RATED AMPS= 16,9 A AC PV INSTALLATION AC PHOTOVOLAAIC MODULE MARKING(NEC 693.52) VRISE SEC 3(COMBINER BOX TO POI) 5 10 Cu. Q22 240.22 0.09% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS XL25)= 2118 A AC PROFESSIONAL Scott Gurney NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 179 241.79 0.75% CONDUCTOR THWN-2,COPPER(75'CTERM)) #P= 10 AWG V-011719-015866 NOMINAL OPERATING AC FREQUENCY 47- HZ AC CONDUCTOR RATING,= 35 A MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DEFLATE= 1 CONTRACTOR: BRS FIELD OPS MAXIMUM AC CURRENT 1.0 A AC AC OUTPUT CURRENT 16.9 A AC AMB,TEMP.AMP.CORRECTION= 0.91 MAXI MUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 VAC ADJUSTED AMP.= 31.85 > 21.2 800-377 4480 GROUNDING NOTES WIRING &CONDUIT NOTES Z Q 1.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690.47]AND[NEC 250.50-60]SHALL BE 1.ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE 0 PROVIDED. PER[NEC 690.47],THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE APPLICATIONS. USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR(USE < CI) 0 (fl INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE POLARIS BLOCK OR NEUTRAL BAR). USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 3.ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS DISALLOWED ABOVE as N 2.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN LIVE PARTS,MEYERS HUBS RECOMMENDED N +. CV THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER) IF SMALLER THAN#6 AWG COPPER WIRE 4.UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF 0 O Cn N" N N PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SURFACE IN ACCORDANCE WITH[NEC 110.2,110.3(A-B)]. U. SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER[NEC 250.64(C)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE Z 0 -N CD (n N 3.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. C COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 6.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR CABLE LISTED AND ceCco0 MC MC 4.PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 250.122],AND ALL METAL IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT;ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS R 0) PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.46]. REQUIRED. CW Y W W 5.MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC 690.42]. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8]FOR MULTIPLE c N W O N N 6.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A CONDUCTORS. 0 -0 N N MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 8.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8"ABOVE 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE Cl) CO In al MANUFACTURER'S INSTALLATION INSTRUCTIONS. 310.15(B)(3)(A)],& L[NEC 310.15(B)(3)(C)]. D ' cn V ♦J 8.ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN 9.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV RESISTANT,AND UL V U CA Q Q GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP 9.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EDGES. EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, DRAWING BY: 10.GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR STRANDED,AND BARE WHEN WET AND UV RESISTANT,RATED FOR 600V EXPOSED. 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. , Brendan Fillmore MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO 12.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION DAMAGE). 13.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS PLOT DATE: 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN(OR MARKED 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC . GREEN IF 4 AWG OR LARGER). POSITIVE-RED(OR MARKED RED),DC NEGATIVE-GREY(OR MARKED GREY) May 1 3, 2023 13.ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE 15.POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: GROUNDED BUSHINGS AT BOTH ENDS. DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED 16.AC CONDUCTORS>4AWG COLOR CODED OR MARKED:PHASE A OR L1-BLACK,PHASE B OR L2-RED, PROJECT NUMBER: ACCORDING TO[NEC 250.166],MINIMUM 8 AWG WHEN INSULATED,6 AWG WHEN EXPOSED TO DAMAGE. PHASE C OR L3-BLUE,NEUTRAL-WHITE/GRAY 773908 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND •USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH[NEC 250.134]OR[NEC 250.136(A)] -'USE-2 IS AVAILABLE AS UV WHITE REGARDLESS OF VOLTAGE. 17.RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, SHEET NAME: FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING MEANS SHALL COMPLY WITH[NEC 690.13]AND[NEC 690.15]. ELEC CALCS 19.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE COMPLYING WITH[NEC 230.6(4)]AND SECURED NO GREATER THAN 6'APART PER[NEC 330.30(B)]. REVISION: PAGE NUMBER: 0 PV6 STANDARD LABELS ADDITIONAL LABELS A LABEL 1 FOR PV SYSTEM DISCONNECTING MEANS WHERE THE • L RAVEN LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LABEL 3 ELECTRIC SHOCK HAZARD OPEN POSITION.POSI -„ -,. . . ,,., [2017NCT ION.(B)J DUAL POWER SUPPLY IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL 1403 N. Research Way TERMINALS ON THE LINE AND [2020 NEC 690.13(B)] ANYWHERE THAT IS POWERED BY BOTH THE UTILITY Orem, UT 84097 LOAD SIDES MAY BE ENERGIZED AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL IN THE OPEN POSITION SOURCES:UTILITY GRID AND AND SUBPANELS.[NEC 705.12(B)(3)] 800.377.4480 PV SOLAR ELECTRIC SYSTEM WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE LABEL 2 USED FOR THE BENEFIT OF ANYONE PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT EXCEPT BLUE RAVEN SOLAR NOR THE DISCONNECTING MEANS AS A POWER SOURCE SHALL IT BE DISCLOSED IN WHOLE OR A AC DISCONNECT A AND WITH THE RATED AC OUTPUT CURRENT AND THE IN PART TO OTHERS OUTSIDE NOMINAL OPERATING AC VOLTAGE. RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND RATED AC OUTPUT CURRENT 16.94 A 2017 0 ] USE OF THE RESPECTIVE EQUIPMENT, [2020 NECNEC 690.5469 .54J WITHOUT THE WRITTEN PERMISSION NOMINAL OPERATING AC VOLTAGE 240 V OF BLUE RAVEN SOLAR LLC. A LABEL 3 NAgCEP IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL ANYWHERE THAT IS POWERED BY BOTH THE UTILITY CERTIFIED DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL AND SUBPANELS. [2017 NEC 705.12(6)(3)J LABEL 10 PV INSTALLATION SOURCES:UTILITY GRID AND [2020 NEC 705.12(B)(3)] PERMANENT PLAQUE OR DIRECTORY TO BE PROFESSIONAL PV SOLAR ELECTRIC SYSTEM LOCATED AT MAIN SERVICE EQUIPMENT DENOTING Scott Gurney POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: LABEL 4 ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN A APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METER. SERVICE DISCONNECTING MEANS. BRS FIELD OPS TO THE BACK-FED BREAKER FROM THE POWER [2017 NEC 705.10 AND 690.56(C)(1)(a)] 800 377 4480 [2020NEC705.10AND 690.56(C)J POWER SOURCE OUTPUT CONNECTION SOURCE. DO NOT RELOCATE [2017 NEC 705.12(B)(2)(3)(6)] [2020 NEC 705.12(B)(3)(2)J THIS OVERCURRENT DEVICE ` LABEL 11 A PERMANENT PLAQUE OR DIRECTORY TO BE LOCATED AT AC COMBINER PANEL. PHOTOVOLTAIC SYSTEM [2017NEC 110.21(B)] Z L COMBINER PANEL [2020 NEC 110.21(B)] 0 Y Q co DO NOT ADD LOADS o co 2 ,r 4L<i SUBPANEL O 0 07 i' N N UTILITY MAIN (IF INTERCONNECTION AC PV PV COMBINER Z E N (/� METER SERVICE PANEL IS MADE HERE) DISCONNECT METER BOX cc W •5aS 2 W W O O OO O O 0 O T O u SOLAR PV SYSTEM EQUIPPED LABEL 6 F— > BUILDINGS WITH PV SYSTEMS SHALL HAVE A O EI:: O CD co WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE 2 2 7 = CD V C.)EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS _ TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY V 0Q 0 SWITCH TO THE Aa 0 OFF'POSITION TO �«a�, IS USED VISIBLE LOCATION AND SHALL INDICATE THE LOCATION IF BREAKER0 SHUT DOWN PV SYSTEM �s OF RAPID SHUTDOWN INITIATION DEVICES. 4 O 1 1 DRAWING BY: AND REDUCE SHOCK HAZARD [2017 NEC 690.56(C)(1)(a)] IN THE ARRAY 1 [2020 NEC 690.56(C)] Brendan Fillmore S — 10 — O OR PLACARD PLOT DATE: RAPID SHUTDOWN LABEL 7 s SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT May 13, 2023 SWITCH FOR SWITCH [2017 NEC 690.56(C)(3)J SOLAR PV SYSTEM [2020 NEC 690.56(C)(2)] -0 PROJECT NUMBER: 773908 LABELING NOTES SHEET NAME: 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL LABELS 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE HANDWRITTEN[NEC 110.21[ DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. 0 PV7