Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
• ROOF MOUNT PHOTOVOLTAIC SYSTEM CODES: CONSTRUCTION NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2018 INTERNATIONAL BUILDING CODE (IBC) CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND 2018 INTERNATIONAL RESIDENTIAL CODE(IRC) ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2018 INTERNATIONAL MECHANICAL CODE(IMC) ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT 2018 INTERNATIONAL PLUMBING CODE (IPC) 2018 INTERNATIONAL FUEL GAS CODE(IFGC) POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) MOUNTED. _ 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER Z SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. NAV 2017 NATIONAL ELECTRICAL CODE(NEC) AS ADOPTED BY CITY OF TIGARD DIG ALERT(811)TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR T EXCAVATION TAKING PLACE O ANY OFCllY TIGARD PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM 'NG DIVISION DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH VICINITY MAP: REQUIREMENTS OF ART. 690 OF THE 2017 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. CLIENT: EMT CONDUIT Approved plans ANDREWZEPP A ATTACHED TO THE ROOF USING CONDUIT MOUNT. C : be on . , 16840 SOUTHWEST ROCKHAMPTON LANE, ` ={ a�ti IGARD,OR 97224 AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL ?` ELECTRIC METER:36 146 463 a • CITY OF TIGARD PHONE:(503)837-9978 su S l;Mo°ritan Rd OFFICE COPY REVIEWED PO EMAIL:AZEPP1967@GMAILCOM SW Rol titoumain Rs SW SAS Mourta n d S CODE �..O IPL11r1i1\T/^�a-+ FINANCE: OTHER � • Q Approved; [ 1Vl.li SYSTEM: ` OTC: [ 7 SYSTEM SIZE(DC):48 X 400=19.200 kW I SYSTEM SIZE(AC):13.920 kW @ 240V Permit#� A., MODULES:48 X FREEDOM FOREVER: f L(JL __O0 ([� FF-MP-BBB-400 ® Address: test-it:, L{_1 f MICROINVERTERS:48 X ENPHASE ... , 44 L�(V 12b:kkai,r►Pchn IQ8PLUS-72-2-US S.LIite #: • By; Date: 5 SITE LOCATION 77..-3 TABLE OF CONTENTS: tt PV-1 SITE LOCATION PV 2 SITE PLAN L, . VALIDITY OF PERMIT PV-2A ROOF PLAN WITH MODULES LAYOUT REVISIONSSEDB -' THE ISSUANCE OF A PERMIT NO REVISED BY DATE V 2B $ BASED ON CONSTRUCTION ROOF AND STRUCTURAL TABLES PV-3 MOUNTING DETAILS DOCUMENTS T OTHER PV-4 DATA SHALL NOT PREVENT THREE LINE DIAGRAM THE CODE OFFICIAL FROM PV-5 CONDUCTOR CALCULATIONS REQUIRING THE CORRECT freedom PV-5A FOREVER ELECTRICAL CALCULATIONS OF ERRORS. ORSC 1 Oc:._ FREEDOM FOREVER LLCINESS PV-6 43445 BUS PARK DR#110,TEMECULA, EQUIPMENT&SERVICE LIST CA 92590 PV-7 Tel:(800)385-1075 LABELS GREG ALBRIGHT V-7A SITE PLACARD PV-8 MICROINVERTER CHART ./ sl (P414 PV-9 SAFETY PLAN CONTRACTOR LICENSE: PV-1 SUPERVISING MASTER ELECTRICIAN 6576S SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS SITE LOCATION JOB NO- 328309 1 5/2/2023 I DESIGNED. BY:I SHE-1 1 CHIMNEY SOUTHWEST ROC KHAMPTON LANE O PIPE VENT 28'-0" T_______TT-0" IN ATTACHMENTS U MODULES RAFTERS }' • Q RAIL `" W r�/ 00 SETBACK mAC DISCONNECT PROPERTY LINE ZI MSP I 111 In JUNCTION (N) JUNCTION BOX BOXPRODUCTION FENCE/GATE METER �fla oclncMICRO (N) COMBINER BOXROOF AREA:2469 SO F4 T INVERTERA (N) / UTILITY DISCONNECT EATON DG223URB CLIENT: COMBINER �. (OR EQUIVALENT) ANDREWZEPP BOX ROOF LINE ril �.•� I 16840 SOUTHWEST ROCKHAMPTON LANE, J (E) UTILITY METER TIGARD,OR 97224 El t4t:IpIzIFp1I:ip.pjiI4p1 / AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL (E) MAIN SERVICE PANEL ELECTRIC iMETER:36 146 463 N 0 PHONE:(503)837-9978 EMAIL:AZEPP1967@GMAIL.COM A ������i # FINANCE: OTHER CO c SYSTEM (N)48 FREEDOM FOREVER: FF-MP-BBB-400 SYSTEM SIZE(DC):48 X 400=19.200 kW SYSTEM SIZE(AC):13.920 kW @ 240V I MODULES:48 X FREEDOM FOREVER: A a • FF-MP-BBB-400 (N) ENPHASE IQ8PLUS 72-2-US �. MICROINVERTERS:48 X ENPHASE AgEle IQ8PLUS-72-2-US A IVA A � . I A 1 4'-� REVISIONS - NO. REVISED BY DATE INI e e freedom I .-. FOREVER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 �` Tel:(800)385-1075 r GREGALLBRIGHT SITE PLAN uF LAN 50'-4" CONTRACTOR LICENSE: NAii, SCALE: 3/32" 1 �� 1 THIS SYSTEM DESIGNED WITH: SUPERVISING MASTER ELECTRICIAN6576S -� i WIND SPEED: 0 WIND EXPOSURE: B SNOW LOAD:20 BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' JOB NO: DATE DESIGNED BY: SHEET 328309 5/2/2023 ,c,io, , , ' LEGEND: BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' THIS SYSTEM DESIGNED WITH: TOTAL ROOF AREA: 2469 SQ FT CHIMNEY WIND SPEED: 0 TOTAL ARRAY AREA: 1008.93 SQ FT WIND EXPOSURE: B ARRAY COVERAGE: 40.86% 0 PIPE VENT SNOW LOAD:20 SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT COMP SLIDE POINT-LOAD: 21.06 ATTACHMENTS LBS u MODULES RAFTERS RAIL SETBACK FIRE ACCESS DIA �,�) `�' plor /� PATHWAYS AC DISCONNECT MSPJ MSP ❑ 9 JB (N)JUNCTION BOX PC' •014 / 001 ° ° (N) COMBINER AD AC BOX JUNCTIONAO I JB I BOX �� lic N D AC `, ❑ ��® ( )AC DISCONNECT I PM I PRODUCTION , D� Ea EATON DG223URB(OR EQUIVALENT) METER Ix D Ac / Ac I ROOF AREA:2469 SQ FT IDC(AC MICRO FA D (E) UTILITY METER I I c Ac Ac CLIENT: INVERTER qC ANDREW ZEPP 224 (E) MAIN SERVICE PANEL / Dc 16840 SOUTHWEST ROCKHAMPTON LANE, COMBINER ROOF LINE A� AD ICBI BOX S41`I, DC DC . Ac qC AHJ:TIG CIT OFR 9TIGA AHJ:CITY TIGARD c c ■ ���� Dc UTILITY:PGE-PORTLAND GENERAL Ac Ac 7 a ELECTRIC ��� Ac Ac METER:36 146 463 aaaYYY777LAl PHONE:(503)837-9978 EMAIL:• � ... ���� .(.\�� FINANCE: OTHER7@GMAIL.COM Ma AC AP ` C C ,,, AD nc SYSTEM: SYSTEM SIZE(DC):48 X 400=19.200 kW SYSTEM SIZE(AC):13.920 kW @ 240V (N) ENPHASE IQ8PLUS-72-2-US fr fj F. F. c MODULES:48 X FREEDOM FOREVER: INVERTER Ac nc FF-MP-BBB-400 E. DAD (N)48 FREEDOM FOREVER: MICROINVERTERS.48 X ENPHASE Dc FA?: IQ8PLUS-72-2-US AC AC AC D AC *. FF-MP-BBB-400 AC D AC qC DC DC �•. AC qC AC AC D AC AC •..I. / AC qC AC cAC AC C .1 1AD �j FIRE ACCESS REVISIONS NO. REVISED BY DATE PATHWAYS MIN _ i freedom FOR E V E R FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: AI ROOF PLAN NOTES: SUPERVISING MASTER ELECTRICIAN 6576S . Viip SCALE: 1 =1 O, Q 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3. JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF PLAN WITH MODULES LAYOUT JOB NO: DATE: DESIGNED BY: SHEET: ROOF DETAILS: TOTAL ROOF AREA: 2469 SQ FT TOTAL ARRAY AREA: 1008.93 SQFT ARRAY COVERAGE: 40.86% SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT COMP SLIDE POINT-LOAD: 21.06 LBS CLIENT: ROOF AREA STATEMENT ANDREW ZEPP 16840 SOUTHWEST ROCKHAMPTON LANE, ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA TIGARD,OR 97224 AHJ:CITY OF TIGARD ROOF 1 22 18 18 181 793 SQ FT 462.43 SQ FT UTILITY:PGE-PORTLAND GENERAL ELECTRIC ROOF 2 11 30 30 91 499 SQ FT 231.21 SQ FT METER:36 146 463 PHONE:(503)837-9978 ROOF 3 8 30 30 271 412 SQ FT 168.16 SQ FT EMAIL:AZEPP1967@GMAIL.COM FINANCE OTHER ROOF 4 7 18 18 1 370 SQ FT 147.14 SQ FT SYSTEM: ---- ---- SQ FT SQ FT SYSTEM SIZE(DC):48 X 400=19.200 kW SYSTEM SIZE(AC):13.920 kW @ 240V ---- ---- ---- ---- SQ FT SQ FT MODULES:48 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS:48 X ENPHASE ---- ---- ---- ---- ---- SQ FT SQ FT IQ8PLUS-72-2-US ---- ---- ---- ---- ---- SQ FT SQ FT ---- ---- ---- ---- ---- SQ FT SQ FT ---- ---- ---- ---- ---- SQ FT SQ FT REVISIONS NO. REVISED BY DATE -� freedom FORE V E R FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT i\V--- )31,-1' (Pjfh CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S I ROOF DETAILS 328309JOB NO:1DA 5/2/2023 I DESIGNED BY:1 PVE28 TABLE 1-ARRAY INSTALLATION II III II II Il=mI I+• - s: .-I MAX MAX RAIL II III II II ROOF MAX UNBRACED RAFTER/TRUSS PENETRATION ATTACHMENT ■ ■ ■ ■ ■ PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE1 OVERHANG(' L-__J L_-_J LENGTH(FT.)1 SISTERING PATTERN2 SPACING �_ ��i =��, (IN.)2 N')3 II III II II LL' ......__IL__.- L '_--J ROOF 1 18 COMP SHINGLE ECOFASTEN ROCKIT COMP SLIDE 2X4 TRUSS @ 24"OC 8.00' NOT REQ'D STAGGERED 48 24" ---J ROOF 2 30 COMP SHINGLE ECOFASTEN ROCKIT COMP SLIDE 2X4 TRUSS @ 24"OC 8.00' NOT REQ'D STAGGERED 48 24" ROOF 3 30 COMP SHINGLE ECOFASTEN ROCKIT COMP SLIDE 2X4 TRUSS @ 24"OC 8.00' NOT REQ'D STAGGERED 48 24" ROOF 4 18 COMP SHINGLE ECOFASTEN ROCKIT COMP SLIDE 2X4 TRUSS @ 24"OC 8.00' NOT REQ'D STAGGERED 48 24" STACKED DETAIL O 0 0 0 For Illustration purposes only 0 0 O 0 0 o II III II ▪II 1.CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION.IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS,NOTIFY ENGINEER OF RECORD IMMEDIATELY. II III II ▪II 2. L•_■ ■ • ■ ■ J WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST,CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS. �:;4 _ _• _■■I 3.WHERE APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. II III II IIII CLIENT: ANDREW ZEPP 16840 SOUTHWEST ROCKHAMPTON LANE, TIGARD,OR 97224 AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL STAGGERED DETAIL ELECTRIC MAX ATTACHMENT SPAN - 48" METER:36 146 463 PHONE:(503)837-9978 For Illustration purposes only EMAIL:AZEPP1967@GMAIL.COM FINANCE: OTHER SYSTEM: SYSTEM SIZE(DC):48 X 400=19.200 kW SYSTEM SIZE(AC):13.920 kW©240V MODULES:48 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS:48 X ENPHASE IQ8PLUS-72-2-US 6 ROCKIT MOUNT -� Z ROCKIT MOUNT ROCKIT MOUNT • FREEDOM FOREVER: FOM FOREVER: FREEDOMBFOROEVER: FREEDOM FOREVER: ROOF SURFACE FF-MP-BBB-400 -- ROOF MEMBRANE SKIRT � - REVISIONS VARIES MH �� ROOF MEMBRANE NO. REVISED BY DATE 2.5"MIN.EMBED. -����� 2.5"MIN.EMBED. 2X4 TRUSS©24"O.C. freedom 25„MIN EMBED 5/16"STAINLESS STEEL LAG mIlir ., -. FORE V E R BOLT OR STRUCTURAL SCREW 5/16"STAINLESS STEEL LAG FREEDOM FOREVER LLC WITH 2-1/2"MIN.EMBEDMENT BOLT OR STRUCTURAL SCREW 43445 BUSINESS PARK DR#110,TEMECULA, AND FLAT WASHER WITH 2-1/2"MIN.EMBEDMENT 5/16"STAINLESS STEEL LAG AND FLAT WASHER CA 92590 BOLT OR STRUCTURAL SCREW Tel:(800)385-1075 WITH 2-1/2"MIN.EMBEDMENT GREG ALBRIGHT AND FLAT WASHER CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S SOLAR PV ARRAY SECTION VIEW I ATTACHMENT DETAIL Scale: NTS Scale: NTS MOUNTING DETAILS JOB NO:I DATE: I DESIGNED BY:I SHEET: 328309 5/2/2023 S.G. PV-3 BACKFEED BREAKER SIZING MAX:CONTIN000S OUTPUT 58.08A @ 240V 58.08 X 1.25 = 72.60AMPS 80A BREAKER-OK SEE 705.12 OF 2017 NEC 225 X 1.20 = 270 270 - 175 = 95A ALLOWABLE BACKFEED CLIENT: ANDREW ZEPP 1BRANCH 6AW ,BARESOPPER L TO GROUND INVERTERS 1#6 AWG,BARE COPPER GROUND 16840 SOUTHWEST ROCKHAMPTON LANE, BRANCH CABLES INTEGRAL TO INVERTERS TIGARD,OR 97224 1#6 AWG,BARE COPPER GROUND AHJ:CITY OF TIGARD (E)UTILITY UTILITY:PGE-PORTLAND GENERAL ENPHASE ICROINVERTERS ---- MICROINVERTERS (• E)225A RATED METER ELECTRIC MAIN SERVICE PANELA METER:36 146 463 1PH,120/240V60HZ ,III PHONE:(503)837-9978 STRING-1 • (N)175A/2P MAIN — EMAIL:AZEPP1967@GMAIL.COM I BREAKER @ FINANCE: OTHER 12 FREEDOM FOREVER:FF-MP-BBB-400/NCI (TOP FED) I I ———— ———- I SYSTEM: ENPHASE IQBPLUS-72-2-US ---; SYSTEM SIZE(DC):48 X 400=19.200 kW MICROINVERTERS (N)ENPHASE SYSTEM SIZE(AC):13.920 kW @ 240V COMBINER BOXA MODULES:48 X FREEDOM FOREVER: �� FF-MP-BBB-400 STRING-2 ,0—ice JUNCTION �1 . MICROINVERTERS:48 X ENPHASE 12 FREEDOM FOREVER:FF-MP-BBB-400 • NEMANil X3Rj (N)20A/2P TO OTHER LOADS s ENPHASE IQ8PLUS-72-2-US --- iI I -� (N)100A RATED •� MICROINVERTERS I ! (1 • AC DISCONNECT EATON DG223URB(OR (N)20A 12P EQUIVALENT) 1 KNIFEBLADE,LOCKABLE, (N)80A/2P PV BREAKER STRING-3 '�—�- ^ NEMA 3R,UL LISTED 12 FREEDOM FOREVER:FF-MP-BBB-400 ——— — ( i —y TO UTILITY I— - - // - UNDERGROUND I (N)20A/2P �� d V FEED ENPHASE IQ8PLUS-72-2-US -- I r + e — MICROINVERTERS T ��1� I \I REVISIONS t(N)20A/2P I A NO. REVISED BY DATE 2 , J 3-#4 AWG,THWN-2 3-#4 AWG,THWN-2 Till _ STRING-4 �_�—_ I 1-#10 EGC,THWN-2 1-#8 EGC,THWN-2 - - 12 FREEDOM FOREVER:FF-MP-BBB-400/� ——— — IN 1"OR LARGER EMT IN 1"OR LARGER EMT - I— - CONDUIT CONDUIT • 8-#10 AWG, -2 :« freedom - 1-/4"#1 EGC,ONDTHVVUIT BRANCH CABLES INTEGRAL TO INVERTERS IN 3/4"EMT CONDUIT F O R E V E R 1#6 AWG,BARE COPPER GROUND FREEDOM FOREVER BRANCH CABLES 6AWGINTEGRAL PO PEINVERTERS 43445 BUSINESS PARK DRER LLC TEMECULA, • 1#6 AWG,BARE COPPER GROUND CA 92590 Tel:(800)385-1075 GREG ALBRRIGHT i l� 47 CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS• JOB NO: DATE: DESIGNED BY: SHEET: 328309 15/2/2023 I S.G. I PV-4 • ' VOLTAGE DROP CALCULATIONS DC VOLTAGE(V) CURRENT(A) LENGTH (FT) VOLTAGE DROP(%) WIRE SIZE RACEWAY 444.84 17.2375 40 0.39% 10 3/4" EMT AC VOLTAGE(V) CURRENT(A) LENGTH (FT) VOLTAGE DROP (%) WIRE SIZE RACEWAY 240 72.6 6 0.18% 6 3/4" EMT NOTE: PER ETO REQUIREMENTS,VOLTAGE DROP CALCULATIONS WILL BE NO GREATER THAN 2%. WIRE SCHEDULE CLIENT: ANDREW ZEPP STARTING ADJUSTMENT MAXIMUM 16840 SOUTHWEST ROCKHAMPTON LANE, STARTING TEMPERATURE ADJUSTED TIGARD,OR 97224 AWG CURRENT FACTOR FOR AHJ:CITY OF TIGARD RACEWAY CONDUCTOR ALLOWABLE CORRECTION CONDUCTOR CURRENT EQUIPMENT # WIRE APPLIED TO MORE THAN 3 APPLIED TO UTILITY:PGE-PORTLAND GENERAL QTY. AMPACITY @ 90°C FACTOR AMPACITY SIZE CONDUCTORS CONDUCTORS CONDUCTORS ELECTRIC 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) @ 90°C IN RACEWAY METER:36 146 463 PHONE(503)837-9978 1 DC MODULE TO MICROINVERTER 2 10 40 17.24 1 1 40.00 21.55 EMAIL:AZEPP1967@GMAIL.COM FINANCE: OTHER 2 AC MICROINVERTER TO JUNCTION BOX 2 10 40 14.52 1 1 40.00 18.15 3 AC JUNCTION BOX TO ENPHASE COMBINER BOX 8 10 40 14.52 1 0.7 28.00 18.15 SYSTEM: SYSTEM SIZE(DC):48 X 400=19.200 kW 4 AC ENPHASE COMBINER BOX TO AC DISCONNECT 3 4 95 58.08 1 1 95.00 72.60 SYSTEM SIZE(AC):13.920 kW @ 240V MODULES:48 X FREEDOM FOREVER: 5 AC AC DISCONNECT TO POI 3 4 95 58.08 1 1 95.00 72.60 FF-MP-BBB-400 MICROINVERTERS:48 X ENPHASE IQ8PLUS-72-2-US REVISIONS ---- NO. REVISED BY DATE ____ _' freedom-- FOREVER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, - CA 92590 Tel:(800)385-1075 GREG ALBRIGHT t,j),,\‘ 6944-- ---- CONTRACTOR LICENSE: ---- SUPERVISING MASTER ELECTRICIAN 6576S CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. CONDUCTOR CALCULATIONS JOB NO:I DATE: I DESIGNED BY:I SHEET: 328309 5/2/2023 S.G. PV-5 I Residential Optional Calculation 9/25/1997 Freedom Forever LLC by:John Sok. Version 2014 STEP 1 Article 220.82(B)(1),(2) Andrew Zepp sq.ft •i 3111 General Lighting load 9,333 VA azepp1967@gmail.com 2 Small Appliance 3,000 VA 16840 Southwest Rockhampton Lane,Tigard,OR 1 Laundry circuit 1,500 VA (503)837-9978 Gen.Lgt,Sm App.&Laun.Load 13,833 VA 4/25/202311:11 328309 STEP 2 Article 220.82(C) 17 General lighting,Sm.Appl.&Laundry 13,833 VA A/C Condenser&Fixed Electric Space Heating QTY Total 1 65%Demand Factor 3 ton • 4,275 VA AHU 1 GAS 1 • 1,200 VA 1 • Heating Load 1,200 VA, A/C#2 • VA AHU 2 Select • VA .Qty • CU Load 5,475 VA A/C#3 • VA AHU 3 Select • VA j Qty_ • A/C#4 • VA AHU 4 Select • VA 1 Qty • Electric Space Heat @ 65%<4,40%>3,vs.A/C @ 100% 5,475 VA A/C#5 v VA AHU 5 Select • VA 1 Qty • CLIENT: STEP 3 Article 220.82(B)(3) Appliance Demand Load 20,727 VA ANDREW ZEPP 16840 SOUTHWEST ROCKHAMPTON LANE, 6,000 VA • 1 Water Heater 6,000 VA TIGARD,OR 97224 1,400 VA • 1 Refrigerator 1,400 VA Dryer Demand Load 5,760 VA AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL 800 VA v Freezer VA ELECTRIC 1,200 VA • 1 Dishwasher 1,200 VA Range Demand Load VA METER:36 146 463 1,127 VA v 1 Disposal 1,127 VA PHONE:(503)837-9978 EMAIL:AZEPP1967@GMAIL.COM 540 VA • Range Hood VA Service Demand 27,603 VA FINANCE: OTHER 1,400 VA • 1 Microwave 1,400 VA ❑ 1,440 VA • Central Vac VA Demand Load Fle 240V,1ph 115 A SYSTEM: SYSTEM SIZE(DC):48 X 400=19.200 kW 288 VA • Mini Refrig VA SYSTEM SIZE(AC):13.920 kW @ 240V ❑ 400 VA • Compactor VA Neutral Demand 91 A MODULES:48 X FREEDOM FOREVER: FF-MP-BBB-400 ❑ 12,000 VA • Tankless heater VA MICROINVERTERS:48 X ENPHASE 1,500 VA • Wine Cooler VA IQ8PLUS-72-2-US Min.Service Req. 125 A El select • Jacuzzi Tub VA ❑ select • Sprinkler VA El select • Well Pump VA select • Fountain Pump VA select ,• Elevator VA Pool Equip.Panel VA Apply Demand 0 9600 Other load 9,600 VA No Demand ❑ Other load VA No Demand Total Appliance Load 20,727 VA REVISIONS STEP 4 Article 220.82(B)(3) NO. REVISED BY DATE Electric Clothes Dryers 5,760 VA _ _ STEP 5 Article 220.82(B)(3) - _ Electric Ranges Col C demand 0 or Number of appliances Cooktop Col B demand freedom ❑s Check Box for Gas Range Cooktop Col B demand Use this area for your own notes FORE E R Oven(s) Col B demand FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,EMECULA, Oven(s) Col B demand CA 92590 Number of appliances 0 Dem.Factor Tel:(800)385-1075 Cooktop&Oven Demand Load GREG ALBRIGHT CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S ELECTRICAL CALCULATIONS JOB NO:I DATE: I DESIGNED BY:I SHEET: 328309 5/2/2023 S.G. PV-5A OCPD SIZES: SERVICE LIST: 20A BREAKER NONE 20A BREAKER 20A BREAKER 20A BREAKER 80A BREAKER 9A BREAKER MATERIAL LIST: QTY. PART PART# DESCRIPTION 48 MODULES PV-110-400 FREEDOM FOREVER:FF-MP-BBB-400 1 JUNCTION BOX 480-276 600VDC NEMA 3R UL LISTED JUNCTION BOX 4 CONNECTORS 240-300 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(FEMALE) 4 CONNECTORS 240-301 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(MALE) 48 MICROINVERTER(S) INV-120-015 ENPHASE IQ8PLUS-72-2-US 1 ENVOY 160-100 "ENPHASE AC COMBINER W/ENVOY PCB,80A" 56 Q CABLE 160-106 "ENPHASE,Q CABLE PORTRAIT FOR 60/72 CELL" CLIENT: 56 Q CABLE 160-105 "ENPHASE,Q CABLE LANDSCAPE 60 CELL" 1 ANDREW ZEPP COMBINER BOX 160-100 ENPHASE COMBINER BOX NEMA 3R RATED 16840 SOUTHWEST ROCKHAMPTON LANE, 1 CABLE 310-300 "ENPHASE,RAW TRUCK CABLE(300 FT.ROLL)" TIGARD,OR 97224 TIGARD 384 CLIP 160-108 AHJ:CITY OF ENPHASE TIE WRAPS/CABLE CLIPS UTILITY:PGE- ND GENERAL 12 SEAL 160-107 ENPHASE SEALING CAPS FOR Q CABLE ELECTRIC 5 TERMINATOR 160-109 ENPHASE TERMINATOR METER:36 146 463 1 DISCONNECT 261-526 ENPHASE DISCONNECT TOOL PHONE:(503)837-9978 EMAIL:AZEPP1967@GMAIL.COM 1 AC DISCONNECT 321-100 100A RATED 240VAC NEMA 3R UL LISTED FINANCE: OTHER 111 ROOF ATTACHMENT 1 RAC-265-002 ROCKIT COMP SLIDE 35 TRIM 1 241-253 ROCKIT TRIM COMP DARK SYSTEM: 91 SLIDER 1 261-603 SYSTEM SIZE(DC):48 X 400=19.200 kW ROCKIT SLIDER COMP DARK SYSTEMS 48(AC): EDO kw@ 240V 27 BONDING CLAMP 1 221-100 N/S BONDING CLAMP MODULES:48 X FREEDOM FOREVER: FF-MP-BBB-400 11 BONDING CLAMP 1 241-404 TRIM BONDING CLAMP 51 MOUNT ASSEMBLY 1 MICROINVERTERS:48 X ENPHASE MLPE MOUNT ASSY 29 SPLICE 1 261-604 ROCKIT SPLICE IQ8PLUS-72-2-US 241 405 7 ATTACHED SPLICE 1 211-101 ATTACHED SPLICE 8 INCH 40 TRIMRAIL 1 261-606 TRIMRAIL UNIV CLIP W/HDW 12 TRIM SPLICE 1 261-605 TRIM SPLICE DRK 21 TRIMRAIL 1 211-115 TRIMRAIL UNIV DRK 48 GROUND LUG 1 260-585 ILSCO GROUND LUG 48 TRIM END CAPS 1 221-200 ROCKIT TRIM END CAPS 111 FLASHING 1 RAC-265-001 GF-1 FLASHING GLV BLK 8X10 REVISIONS NO. REVISED BY DATE freedom FOR E V E R FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S EQUIPMENT&SERVICE LIST JOB NO:I DATE I DESIGNED BY:I SHEET: 328309 5/2/2023 S.G. PV-6 NOTES: PHOTOVOLTAIC SYSTEM, _ _ M DO NOT UP SIZE MAIN BREAKER 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 EQUIPPED WITH RAPID SHUTDOWN \ MAIN BREAKER DERATED TO 175 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. DO NOT UPSIZE 1 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. 690.12 B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. ARIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT TURN RAPID PV SYSTEM AC DISCONNECT WITH POP-RIVETS OR SCREWS SHUTDOWN SWITCH TO RATED AC OUTPUT CURRENT - 58.08 AMPS THE "OFF" POSITION TO AC - AC NORMAL OPERATING VOLTAGE - 240 VOLTS SHUT DOWN PV SYSTEM 690.14, 690.15,690.54 AND REDUCE SHOCK HAZARD IN THE ARRAY "WARNING" 690.56(C)(1)(B) PM DUAL POWER SOURCES SECOND SOURCE IS PHOTO- VOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 58.08 AMPS CLIENT: r ANDREW ZEPP AC NORMAL OPERATING VOLTAGE - 240 VOLTS ' 16840SOUTHWESTROCKHAMPTONLANE, TIGARD,OR 97224 AHJ:CITY OF TIGARD rThp ~ UTILITY:PGE-PORTLAND GENERAL ELECTRIC 690.54 METER:36 146 463 OPTIONAL SOLAR LOAD CENTER EMAIL:ZEPP196 @G RAPID SHUTDOWN SWITCH FOR EMAIL:AZEPP1967@GMAIL.COM FINANCE: OTHER SOLAR PV SYSTEM cm. cm. ARRAY SYSTEM: SYSTEM SIZE(DC):48 X 400=19.200 kW 690.56 C 3 SYSTEM SIZE(AC):13.920 kW @ 240V ( )( ) MODULES:48 X FREEDOM FOREVER: A FF-MP-BBB-400 JAB MICROINVERTERS:48 X ENPHASE A I O8PLUS-72-2-US "WARNING" INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS 1 NEC 690.31(G)(3) &(4), IRC R324.7 OVERCURRENT DEVICE "WARNING" REVISIONS (UNLESS BUSBAR IS FULLY RATED) No. REVISED BY DATE 705.12(D)(2) PHOTOVOLTAIC POWER SOURCE _ _ MAXIMUM VOLTAGE 60 V EVERY 10'ON CONDUIT AND ENCLOSURES freedom F O R E V E R MAXIMUM CIRCUIT CURRENT N/A A — — — —j FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, MAX DC-DC CONVERTER 15 A CA92590 OUTPUT CURRENT Tel:(800)385-1075 GREG ALBRIGHT .,1 (Pjli-Ar-- , 1 a CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S LABELS JOB NO:I DATE: I DESIGNED BY:I SHEET: 328309 5/2/2023 S.G. PV-7 . • . 2. freedom • • reedOM A ELECTRICAL CHARACTERISTICS :134±2 flifill IrllIlifiTII 'IIII7'lllll llll,lll I IifI IIllFOREVER Characteristics FF-MP-BBB-400 lltlliIllgllllllpelllll'IfIIIi1UI 'lllill!'Illllllii(' Frame Profile Maximum Power(Pmax) 400W 1 IIIIII! 1,111111111 illllll114111lllll IllillFL Ilplill Maximum Power Voltage(Vmp) 31.01V IIIIill1111plltp 11111l�ll!IIIII1'1llillll11lllllllll 111111l II I; 11111lllil' it iI IIB11J111II lIf Frt.,' __ Maximum Power Current(Imp)[A] 2.90A [ ' 111I1 Ho!I II, a III' Hi IiIIIIIII'4 I 11 1i1111lllll14111 III'll111111lI'Ll1I1111. Open Circuit Voltage(Voc)[V] 37 04V h!, �111111.11111i' 1 !IIIIIIII i iil'illlll�1 I 1 Short Circuit Current(Isc)(A] -' llllllilll ''1 rllilllllII 1I 111111'I I I co 1 13.79A " RIM Iilll1 I'�illiUlll Ili1ll I jllllllll Illlllllllf Module Efficiency20.48% Milli 1111ll 1IIIII1i1IIIU,111i11111 1111111111111111111 �. '_:_ hiiiiIIIIl111111 Jri1111110111111I IIIIIII,I1101l1 Power Tolerance 01+5W '111i11111(1]111111LI1.1111illi11111IIIIt Iillllll�l1111111 35[1.38] Illlllllll�llllll�ll'i llil lllliIIIII ;IIIIIIII 11111111111 1- Irradiance of 1000W/m2,AM1.5, Illil� STC 1111/11111' 111 ll;111111ll III 111111111 Illll111111 Cell Temperature 25°C 111111111 1111E 1111111 l 1111111t_ lll11lill�11111111111 IIIIIIIIIL1111D1111llllil[llllll11 i111111111 F''llllll MECHANICAL CHARACTERISTICS Front Cell Type Mono perc,182 mm-half cells,108(6x9+6x9) III' 1I 111 1/111111 Weight 22 1 kas(48.7 Ibs) 35 Dimension 1722 x 1 134 x 35 mm(67.80 x 44.65 x 1.38 in) i..CMM Front Glass 3.2 mm(13 in) 72e00.LM 1 350MM ;unction Box iP68(3 Bypass Diodes) Output Cables 1200 mm(47.24 in) I {{ II I Connector Staubil MC4 I Frame& nstallat,ion Anodized aluminum pro.':e N.. - - Product Label OPERATIONS CHARACTERISTICS Operational Temperature -40°CH+85` I I � Max System Voltage 1500V ., Max Series Fuse Rating 25A � r g g � Safety Class Class 1 3IIIIe Fire Rating Type 1 s ( YP I, t MECHANICAL LOADING Snow Load 5,400Pa(1131b/ft2) Rear Side Design Load 2,400Pa(501b/ft2) PACKAGING INFORMATION i Container 20'GP 40'HC I Pallets per Container 6 26 /I • • .. _. 350 MM-... 1...- Panels per Container 186 806 Back Side Panels per Pallet 31 31 Packaging Bon Weight 679 kg(1497 lbs) - CURRENT-VOLTAGE CURVE Panels per Pallet 1785 x 1130 x 1 180 mm (70.28 x 44.49 x 46.46 in) 14 14 1000W/re' 12 _ 10°C \� 12 25°C TEMPERATURE RATINGS io - 40°C V'i 10 800W/rn' Q 55°C ,, \ Q -- 70°C Temperature Coefficient of Pma. 0.350%/°C 8 70°C \ \ e 600W/rn' ` 100% Temperature Coefficient of V°° -0.275%/°C U 4 1 U 4 400W/m' Product Linear warranty warranty Temperature Coefficient of i�� +0.045%/°C 2 2 200W/in' Nominal Operating cell Temperature(NOCT) 42°C±2°C so cm 0 p 10 20 30 ���40 00 l0 20 30 ° 40 E Voltage(V) Voltage(V) 14 0% 0 i 5 12 25 UL61730.UL61215 IS09001.ISO 14001 Free, _...Moo_,, _., r, s,_. a. _._1;r K o00 Year > .,....E„,. ,.,... „ - .. .. .. ..:>,-,, ..�.:,.,, . ;It,•. .. .� : �:. ;- : ,. . . , ,n ems, �- ,� _. ,..,:.,,::.,,<.�., .�._, ,.... ,.. >�, „�..�x �� k. a F. , t t ... �� ::.: _ , .,, c F=w� .ems „�' � x �_,� >c. „.�' ias • ( . Y--. aP .:`�gy -: t.$:a` iMOW i. •'. «a•'C .,k., ;mow , �r ft �� is - � ,_. �- �. ..�. �":y��x�. z�' �' x _ ag'-�n'xt r`E P '�' 4'iY .£ K T S w� fix': `•;�s � it's c aa -�x k. .. r r cog * * t- ".'� - _. , :gip:= 4 - _ y, �a� tom' ¢sYs va .x a _ 4 ., .v.:<'z-_ dt.`P�. �a.� .. " ��.. ..�i � jj - -# • :S �s` },� may+ ,?j� i� .xy .a�:.';°' ' Z' ;.}' ,&, - .f=$ : �A,�' „. T., ,pis®'y. `.} zx,;; ye"'�z" „Y^ a `ma's JJ �rc� ay, yy.� 44: - ,�{ a.4 'L'z� ems" S{ sue+} it z may. -:'x'_ ems$ j'' j'� .fie '�s^fpr ,). :--.;;Ti` £ E 3' £ e£ ,s ' - ya E , t K'z-_%t•� •- Y ': '�� �:ice ,Y A �,,�.e >'�.;- ,.gam;=n :°ez '� �,�>:. , -,. t a > , s. 3 • • x i$ y �- am _ a _ r �, a � ti Y _ 4- _ � R . ss : 'am s . `. +by �. x ,.�.. �e- }." :x_ :'-w 5w F' ,. "� • .. »i .F.K -, Y3b am �L " ��,� #}�°� :am ? Zya� Y .a''�' a4 a ;�v3 '_ 5,� .r,.^ a _ �.^ 2 teR» ; ,: . . =a - *kw *4;7 7 3is .P= ' : - >: ; weiviiit . w - ,y n . .p a tt - ag «,rf .:.->-. <� � � :�, * '3 _4g. :, - `Oat =a'€:r, - ort4steetx : ,. _ ., -. 4. � rs * � a�. ,, i ,a*,.,.,,- r -.M,r., :�,: : :. ` - � � " :.�, s a1< ,e- ;, 3�. ..y. Ve .�s : �`� ra ",.fi" s ._ :. a., .. ..:# :, , r � :. . : . _ s . _ x t: fi '' . ��,� u . � * ' ,a : r s , �: � :� _`--, h a r � >�°' a _` - P n =, , . fig-1" ��a Photovoltaic(PV) Module Safety Qualification-Part 2: Requirements for Testing [CSA C22.2#61730- This certificate confirms the model(s)for the product listed are in compliance and authorized to bear the Certification Mark(s)shown below when 2:2019 Ed.2] made in accordance with the conditions set forth in the Certification Agreement and Listing Report.This document is for use with the Design Light Consortium or California Energy Commission application only. Terrestrial Photovoltaic(Pv) Modules-Design Qualification And Type Approval-Part 1:Test Requirements [UL 61215-1:2017 Ed.1] Basic Listee: PT IDN SOLAR TECH Multiple Listee: Freedom Forever Procurement LLC KOMPLEK KABIL INDONUSA ESTATE, Terrestrial Photovoltaic(PV) Modules-Design Qualification And Type Approval-Part 1-1:Special Address: BLOK A NOMOR 19B, BATU BESAR, Address: 43445 Business Park Drive,Suite 110, Requirements For Testing of Crystalline Silicon Photovoltaic(PV) Modules [UL 61215-1-1:2017 Ed.1] Batam Temecula,CA 92590 Indonesia Terrestrial Photovoltaic(Pv) Modules-Design Qualification And Type Approval-Part 2:Test Country: Country: USA Procedures[UL 61215-2:2017 Ed.1] Product: Crystalline Silicon Photovoltaic(PV) Modules Party Authorized to Apply Label: PT IDN SOLAR TECH Report Issuing Office: Intertek Testing Services Shanghai Limited Brand Name: Freedom Forevert ,`. �.� *t : MIL ..44„M MO S, .;V"_r giTt ,, Z`Ei:a .Q S'S `, .''', Control Number: .5019087 Authorized by: •l/ 4106- FF-MP-BBB-followed by 365,370,375 or 380. NUSA120H-followed by 365,370,375 or 380;followed far L. Matthew Snyder, Certification Manager Models: by MB. FF-MP-BBB-followed by 395,400,405 or 410. NUSA108H-followed by 395,400,405 or 410;followed VALID LISTING MARKS by MB. C 0US Intertek This Certificate of Compliance is for the exclusive use of Intertek's Client and is provided pursuant to the Certification Agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the Agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the Agreement,for any loss,expense or damage occasioned by the use of this Certificate.Only the Client is authorized to permit copying or distribution of this Certificate and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the Agreement and in this Certificate.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the Agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights,IL 60005 Telephone 800-345-3851 or 847-439-5667 Photovoltaic(PV) Module Safety Qualification-Part 1: Requirements for Construction [UL 61730- 1:2017 Ed.1+R:30Apr2020] Standard(s): Photovoltaic(PV) Module Safety Qualification-Part 1: Requirements for Construction [CSA C22.2#61730-1:2019 Ed.2] Photovoltaic(PV) Module Safety Qualification-Part 2: Requirements for Testing[UL 61730-2:2017 Ed.1+R:30Apr2020] +'^i,. 4.�'_ $• "S"• zR�. � 9C"Yf� �. "€ g'a' .,P �'v'�' may s ti at•,. ` .: •.iT>.'S.�F ``.'"'t r±' y�.,yts.,, �i- ` i':$:" .,.,a --L` ..Y. . •_, r ... , v§'4�,$t.�#. � ,_ _ .. �,g.+{§.i.'�.�a :3� �} cx�,s° 't :n_ .+S" .Y.�^{'a -sTi::' ,t `a�..�.c�.a.:� :'' � .. -r .: ..a.x- ,�, k<a, .. , :r ..tea :.._.. <. - .... �:' "'.:_` j= 'r+" `, -�''�'Y - _ ,.l £ .tF xF( r e$,� ,•T,,. <3"' •-a {- z,_ .. ,r ,-{s :,,g.„f:,. w, .+' . d� ,' . . . .. .. - . s: a � s xc._ - 3s _..s. ..;._-_• <`_ _ "} - ^5. 't}� 4e`T ~3.�.. :� .,..?., ram.. .% z��=:m" " .- �-ems..a,.,. .,,... _ �' st. _ 3 < 74 .x4 r' i '�'`, am," - ,:'f. ,.<1.:- _- 'q £3 '3. �r3 -d+ 't� _�. �f tit �.�.-i�- ��, � l�. Y � `i �`1. i 1. - �i �� '�� �. '� ,.�.A' �� "''' i, t._ i�;+, .., i. �_. =� _r �'C'a :',:. ��'l 1��414- ,I,.iL ll ,,.�,'"�-, z��iiili �.il'll' �:�1 .�ltiti'_��.�1.�� �t''i-�, ''t ;�'�-� i_: � �� ���, k-. s � l'. �l � tr a. " , to .. s-" -. :icr.,._ ,:. ,. < , s. , _ . ,>5-- , ..... rt c,_, -.-+e < -,,. ‘3 v < :1,::::. z 4: "'`3•`=N (,.''"' , .,- . : v e ENPHASE. DATA SHEET I08 Series Microinverters INPUT DATA IDCI I08-60-2-US I08PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US 108H-240-72-2-US I08H-208-72-2-US' I Commonly used module pairings' w 235-350 235-440 260-460 295-500 320-540+ 295-500+ Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 14 IN Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage v 50 60 Max DC current'[module Isc] A 15 Overvoltage class DC port II 1Qer. _ ._ DC port backfeed current mA 0 III 1 Qe+ j II PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit I Pg OUTPUT DATA IACI IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US I68H-240-72-2-US I08H-208-72-2-US' -, I IP Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal(L-L)voltage/range° V 240/211-264 208/183-250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 I08 Series Microinverters Extended frequency range Hz 50-68 Easy to install AC short circuit fault current over 2 4.4 Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- • Lightweight and compact with 3 cycles Arms defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors Max units per 20 A(L-L)branch circuits 16 13 11 11 10 9 power to AC power efficiently.The brain of the semiconductor-based microinverter • Power Line Communication Total harmonic distortion <5% is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced Overvoltage class AC port III 55nm technology with high speed digital logic and has super-fast response times • Faster installation with simple AC port backfeed current mA 30 to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling Power factor setting 1.0 energy systems. Grid tied power factor(adjustable) 0.85 leading 0.85 lagging High productivity and reliability Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 • Produce power even when the Enphase grid is down* CEC weighted efficiency % 97 97 97 97.5 97 97 • More than one million cumulative Night-time power consumption mw 60 a z, hours of testing MECHANICAL DATA year limited 40°C to+60°C( 40°F to+140°F) 1: � ;I- warranty • Class II double-insulated Ambient temperature range enclosure Relative humidity range 4%to 100%(condensing) Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative • Optimized for the latest high- DC Connector type MC4 Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. powered PV modules Dimensions(HxWxD) 212 mm(8.3")x175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Microgrid-forming43 • Natural convection no fans Complies with the latest Cooling Approved for wet locations Yes glir advanced grid support** CERTIFIED Pollution degree PD3 • Remote automatic updates for Enclosure Class II double insulated,corrosion resistant polymeric enclosure • the latest grid requirements Connect PV modules quickly and easily to IQ8 Series IQ8 Series Microinverters are UL Listed as Environ.category/UV exposure rating NEMA Type 6/outdoor • Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with profiles grid of anCOMPLIANCE a cable with plug n play MC4 connectors. various regulations,when installed according to range manufacturer's instructions. • Meets CA Rule 21(UL 1741-SA) CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 No.107.1-01 requirements Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other *Only when installed with IQ System Controller 2,meets (1)The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See names are trademarks of Enphase Energy,Inc.Data subject to change. UL operatesonly grid-tied IQ8H-208V in mode. the compatibility calculator at https://link.enphase.com/module-compatibility(3)Maximum continuous input "IQ8 Series Microinverters supports split phase,240V. DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) I0BSE-DS-0001-01-EN-US-2022-03-17 IQ8H-208 supports split phase,208V only. Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-17 aihn id�•rvaorkimr Enphase IQ Combiner 3-ES/3C-ES MODEL NUMBER IQ Combiner 3-ES(X-IQ-AM1-240-3-ES) IQ Combiner 3-ES with IQ Gateway punted circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. IQ Combiner 3C-ES(X-IQ-AM1-240-3C-ES) IQ Combiner 3C-ES with IQ Gateway printed circuit board for integrated revenue grade PV production Enphase The Enphase IQ Combiner 3-ES/3C-ES metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%)Includes Enphase Mobile Connect LTE-M1(CELLMODEM-M1),a plug-and-play industrial-grade cell modem for systems up to IQ Combiner 3-ES/3C-ES With Enphase IQ ateWay and Integrated 60 microinverters(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the IQ HE IVIl Cell modern(included only with IQ Battery and IQ System Controller and to deflect heat. X IQ AM1 240 3 ESCombinerMICROINVERTERS,ACCESSORIES AND REPLACEMENT PARTS(not included,order separately) 3C-ES)consolidates interconnection Supported Micro inverters 106,1071Q8 Do not ma 106/7 Mic nverterswth 108 X IQ AM1 240 3C ES equipment Into a single enclosure and Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-M1 with 5-year data plan for Ensemble sites streamlines PV and storage installations by (COMMS-CELLMODEM-M1) Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. providing a consistent,pre-Wired solution for BRK-10A-2-240 Circuit breaker,2 pole,isA,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 fesldentla applications S. t offers Lip to four BRK 20A-2P-240 Circuit breakeC2pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity-one pair ir 2-pole input circuits and Eaton BR series XA SOLARSHIELD-ES Replacement solar shield for Combiner 3-ES/3C-ES busbar assembly. �ENPMAse XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3-ES/3C-ES(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 3-ES/3C ES ELECTRICAL SPECIFICATIONS S t Smart Rating Continuous duty ! •Includes IQ Gateway for communication and control System voltage 120/240 VAC,60 Hz •Includes LTE M1 cell modem(included only with Eaton BR series busbar rating 125 A +R IQ Combiner 3C-ES) Max.continuous current rating 65 A •Includes solar shield to match Ensemble esthetics and Max.continuous current rating(input from PV/storage) 64 A deflect heat ns ' Max.fuse/circuit rating(output) 90 A , -Flexible networking supports Wi-Fi, Branch circuits solar and/or storage Ethernet,or cellular ( 9) Up to tour 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included •Optional AC receptacle available for PLC bridge •Provides production metering and consumption Gateway breaker 10A or 15A rating GE/Siemens/Eaton included monitoring Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers i •' MECHANICAL DATA Simple i Dimensons WxNeD - - - ( ) 37.5 x 49.5 x 16.8 cm(14.75"x 19.5"x 6.63").Height is 21.06"(53.5 cm)with mounting brackets. •Reduced size from IQ Combiner*(X-IQ-AMl-240-2) Weight ZS kg(16b lbe) •Centered mounting brackets support single Ambient temperature range -40°C to+46°C(-40°to 115°F) stud mounting •Su Cooling Natural convection,Supports back and side conduit entry plus heat shield •Up to four 2-pole branch circuits for 240 VAC Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction X IQ AMi-240 3C ES plug-in breakers(not included) Wire sizes •20 A to 50 A breaker inputs 14 to 4 AWG copper conductors •00 A total PV or storage branch circuits •60 A breaker branch input 4 to 1/0 AWG copper conductors )j •Main lug combined output:10 to 2/0 AWG copper conductors •Neutral and ground 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Reliable Altitude Up to 3000 meters(9,842 feet) r' •Durable NRTL certified NEMA type 3R enclosure INTER NET CONNECTION OPTIONS ', i- • Five-year limited warranty Integrated Wi-Fi 802.11b/g/n 0 Iwo years labor reimbursement program coverage Cellular CELLMODEM-M1-06 4G based LTE-Mt cellular modem(included only with IQ Combiner 3C-ES). included for both the Combiner SKU's Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. •UL listed Ethernet rt Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) +fs COMPLIANCE 6 Compliance,Combiner UL 1741,CAN/CSA C22 2 No 107.1,47 CFR,Part 15,Class B,ICES 003 UI Production metering:ANSI C12 20 accuracy class 0.5(PV production) 1r L X IQ AMl 240-3-E8 Consumption metering:accuracy class 2.5 Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 usTEn To learn more about Enphase offerings,visit gnph�s EN PHAS E" To learn more about Enphase offerings,visit enphase com v _g Enphase L e,v All Enphase, E pi ,5,ei3C ES,and other t erarLso,e v ENPHASE. a,ei arle is Fs of Enphase Enegy Inn Data subject to change 10 17 2022 vice names ©2016 Eaton. All rights reserved. pe.eaton corn tem Eaton general duty non-fusible safety switch DG223URB UPC:782114731154 Dimensions: • Height: 19.25 IN • Length: 7.38 IN • Width: 9.13 IN Weight:12 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: Non-fusible, single-throw • Amperage Rating: 100A • Enclosure: NEMA 3R, Rainproof • Enclosure Material: Painted galvanized steel • Fuse Configuration: Non-fusible • Number Of Poles: Two-pole • Number Of Wires: Two-wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet - DG223URB Certifications: • UL Listed Product compliance: No Data , • ao4 Ec!L!9flJ'!ste ®v For ROCK ROCKIT COUPLING The fast installing Rocklt Coupling easily attaches to the module frame to bridge the gaps between modules. k 4: f SKIRT The sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically- pleasing finishing touch. ROCKIT MOUNT ! - Featuring integrated bonding pins, the Rocklt Mount connects to the Slide and can easily be RACK h ,_ .,,,,_„,-,- __ ... _, _,..... ....-: positioned for fast installation. Features top- = . down leveling. c Illifillk COMPLETE RAIL-LESS RACKING SYSTEM - The Rocklt system is the industry's premier rail-less PV racking system for composition shingle,tile, and metal roofs. Designed in conjunction with the needs of Pk Composition Shingle, installers, Rocklt quickly&easily installs with a single tool. Tile,Metal Featuring an easy-to-position alignment slide and a top- ROOF TYPE , !�1 down leveling system, Rocklt is logistically intelligent with no need to ship or transport long rails. Components are •••• available in a black finish that complements both commercial •••• trail-pass ' ,,; and residential applications.Conforms to UL 2703. RACKING t FEATURES & BENEFITS _ • Patented watertight technology StrucaraFAttach Direct-Attach • • Fully integrated bonding ama+MeaT • Top-down leveling system ROCKIT COMP SLIDE • North-South adjustability Available in four variations,the Rocklt • Single tool install . : " Slide allows installation on composition • Florida Product Approved for composition shingle roofs WATT , _ , ' t. TIGHT-'-- 25 YEAR WARRANTY shingle,tile,and metal roofs. E R A Iv E M L P E MOUNT STREAMLINED INSTALLATION WITH E°""°`°°" °v 1` `-- Attaches and fully bonds MLPE's(Module MINIMAL ROOF PENETRATIONS Level Power Electronics)to the module frame n. with a single bolt clip. ECOFASTENSOLAR COM S structural ENGINEERS May 16,2022 EcoFasten Solar LLC 4141 W Van Buren St,Ste 2 Phoenix,AZ 85009 TEL: (877)859-3947 Attn.: Eco Fasten Solar LLC-Engineering Department Re: Report#2015-05884HG.07.01—EcoFasten-Rocklt System for Gable and Hip Roofs Subject: Engineering Certification for the State of Oregon PZSE, Inc.—Structural Engineers has provided engineering and span tables for the EcoFasten-Rocklt System,as presented in PZSE Report#2015-05884HG.07.01, "Engineering Certification for the EcoFasten-Rocklt System for Gable and Hip Roofs". All information,data,and analysis therein are based on,and comply with,the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2019 Oregon Structural Specialty Code based on 2018 International Building Code 3. 2018 International Residential Code 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV)Panels,November 1,2012 by ICC-ES 5. Aluminum Design Manual 2018, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category II Seismic Design Category=A-E Exposure Category=B, C& D Basic Wind Speed(ultimate)per ASCE 7-16=90 mph to 180 mph Ground Snow Load=0 to 60(psf) DIGITALLY SIGNED This letter certifies that the loading criteria and design basis for the S�RUCTUR2, EcoFasten-Rocklt System Span Tables are �E G�NF FFss in compliance with the above codes. I �N FR goy 85763 If you have any questions on the above,do not hesitate to call. OREGON 1 q�oV 8,20‘(\t`Q- Prepared by: K. Z P� PZSE, Inc.—Structural Engineers EXPIRES: 06/30/2024 Roseville,CA 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com