Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plans
FP.52223-- Cr5.0 0.0 0010 #m• o 5'fZN SCOPE OF WORK FIRE ALARM EQUIPMENT SYMBOL LIST ° Ow w NEW SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT Y MODIFY AN EXISTING ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM WHICH INCLUDES CENTRAL STATION OFF-SITE REPORTING BY ADDING e 2 °C in CEILING MOUNT HORN/STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4" OCT, SINGLE OR 5 YLU HORN/STROBES, AND STROBES IN SUITE 230 (MERCER GLOBAL). (NAC AND CANDELA NOTED AT DEVICE) PC2WL DOUBLE GANG BACK BOX CEILING MOUNT N C CEILING MOUNT STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4" OCT, SINGLE OR CEILING MOUNT 4 (NAC AND CANDELA NOTED AT DEVICE) SCWL DOUBLE GANG BACK BOX 41141§ GENERAL NOTES 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA NOTIFICATION CIRCUIT SCHEDULE a s m pi 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE VOLTAGE DROP CALCULATIONS . It THAN ONE FLOOR SHALL BE RISER RATED. N2-1 HORN/STROBES, STROBES FL2 RR, SOUTH CORRIDOR & ELEV LOBBY NACO2 0.336 375 14 0.77 19.63 YES 3.79% 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. N2-2 EXISTING NOTIFICATION DEVICES EXISTING NOTIFICATION *MAX ASSUMED* NACO2 1.500 400 14 3.68 16.72 YES 18.06% 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND N2-3_HORN/STROBES, STROBES EXISTING DEVICES+ FL2 MERCER GLOBAL: 212,200,201,207,206,205 NACO2 0.437 790 14 2.12 18.28 YES 10.39% REVIEWED/APPROVED: LIGHTNING PROTECTION DEVICES. - 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY N2-4 EXISTING NOTIFICATION DEVICES EXISTING NOTIFICATION *MAX ASSUMED* NACO2 1.500 400 14 3.68 16.72 YES 18.06% - --' PROTECTED. *****POINT TO POINT METHOD OF CALCULATION 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS FIRE ALARM CIRCUIT". BEN BREIT-4460LEA 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.4 PUBLIC MODE (NFPA 72). $, 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION BATTERY CALCULATIONS SK-5495 NACO2 a .�,, k . 3 : , NJ OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.4 (NFPA 72). 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH SECTION 7.5.62 (NFPA 72). SK-5495 REMOTE POWER SUPPLY 1 0.0750 0.0750 0.2050 0.2050 1 : N2-1 NAC CIRCUIT 1 1 0.0000 0.0000 0.3360 0.3360 CITY OF t , r N2-2 NAC CIRCUIT 2 (MAX ASSUMED) 1 0.0000 0.0000 1.5000 1.5000 BUILDING Di 33IIUi SITE _N2-3 NAC CIRCUIT 3 1 0.0000 0.0000 0.4370 0.4370 N2_-4 NAC CIRCUIT 4 (MAX ASSUMED) 1 0.0000 0.0000 1.5000 1.5000 Ce _ STANDBY TOTAL 0.0750 ALARM TOTAL 3.9780 _ *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* W AMPS (A) X TIME (H) = AMP-HRS (AH) 20% DEBATE _ STANDBY 0.0750 X 24 = 1.8000 'L SW HAMPTON ST ALARM 3.9780 X 0.0833 = 0.3315 - W - TOTAL AH = 2.1315 2.5578 -r L /BATTERIES TO BE INSTALLED: (2)12-7.0 AH I `�y o 64 rn / W V J 11 ) li W > co On Y ~ "/ � C� m = ° � �. F FIRE ALARM OPERATIONAL. MATRIX 0 & OL c LL L1.1 Q j OD NO CHANGES '-7-----‘ OO W LJJ N FROM Nrrlin AC SOURCE STPP OR ® TO NEXT DEVICE () N IIII.,II)I PREVIOUS DEVICE J I EOL(4R.7KG) /Q W 0 {•l• III III NAC_ NAC _ 0.. 2 - I- L NAC IN NAC OUT (TYPICAL 14/2C7 (TYPICAL 14/2C) DWG REV./DATE Q„, 110 10111 ADDRESS SCHEDULE NAC 0 05/01/23 NO CHANGES ° ° ��J) �° DRAWN BY: o IIj ���,\ X -o CA © CAUTION: 6 r•ii CHECKED BY: MATRIX DO NOT LOOP WIRE UNDER B.I B TERMINAL 1. SYSTEM SENSOR BREAK WIRE RUN TO PROVIDE UNIVERSAL MOUNTING PLATE FILE NAME: SUPERVISION OF CONNECTIONS. NO CHANGES SW,P2W,SCW,PC2W,P2RK FA.dwg L-SERIES:SWL,P2WL, DRAWING#: SCWL,PC2WL FA-1 °STROBE AND HORN/STROBE ORIG.SHEET SIZE.11"x 17" NOT TO SCALE #OF DWGS IN SET: SHEET 1 OF 2 000 O M O it�O •m 0 8C9) mOo 9.3 Liw Y N W Y to Jto N illikl i,t1.....::::z::,...:.::....... 4Ai , ___L .......„,,,.. 1 T ' i _.... .7.;,, ....._ N �ti, CONFERENCE 1 3 =E, 2m5 • • • • • • N2-3f CONFERENCE CONFERENCE 1 C 30CQ EOL \ I206 207 N2-3e 1 N2-3d I 1 15CQ 15CD" C C OFFICE OFFICE 204 { - j �t 208 li W I— OFFICE z N2-3c OPEN OFFICE W 12031 75CD V c t 201 OFFICE 209 W o Q rn CV a AREA OF WORK w FA-2 OFFICE y 2oz f. © o 0 © ro- o--- o-®1 ® © m Q co Q _r ; OFFICE _�_.. .�� - � © Q O Q m kz1oJ � Iz LLJ - =I Nom „co COO r� N2-3bCL E 15CD 1 IT STOR. 1 ., . _ 0 ill p W / € C _ 0 U rn Q l 211 1 ' • ie�- ' _ ales 0 Q w o LL i; a 2N � � RECEPTION OFFICE ` 1 12001 _� � BREAK � C � ;�` �� {�` � �€; ,��_ � � � REV.I oat a .a - DWGE � 1 12131 N2-3a 212 I 1 3 "^� • © 0 05/01/23 15CQ ' Ni J -, 1E� `nw EI V 44 ... .. � FROM PREVIOUS DEVICE ON E < - 1 ''''''L.:' E--1+ '�, I ''s t DRAWN BY: } I� CIRCUIT N2-3 FROM NACO2 d"- -'""` ; CA f z DEVICE NUMBERS TO BE I € �: ,m,— a °k,. at,� a,."' .._at DOCUMEMm ON AS-Ewer. C :r I �' ._. .-.-.-. .. _. C : _... _ _._ _ ® CHECKED BY: "Ti"< F �1111k _ a� k *f E FILE ME FA.dwg MERCER GLO3AL OVERALL DRAWING#: ,Bill"' °Ii,I, 2N D FLOOR PLAN ° 4' 8' 16' Ilol"''''I�IIII 2N D FLOOR PLAN Fa-2 I II ORIG.SHEET SIZE:11'k 17" 'IIIIII IIIII' SCALE: 1/8"=1'-0" III II 2 #OE DWGS IN SET: IIII NOT TO SCALE SHEET 2 OF 2