Loading...
Plans (2) PHOTOVOLTAIC R i 'lireril of 0 MO N ��U T SY �a STE .�.M 25 M - infiit solar MODULES-ROOF MOUNTED - 10.125 kW DC, 9.984 kW AC, 16549 SW DARWIN LP, TIGARD, OR 97224 CITY _,._:Ey PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SITE DETAIL: ; r ,�B4Y�'IU�PIl4:NON3 SHEET INDEX: SYSTEM SIZE: 10.125 KW DC UTILITY: PORTLAND GENERAL ELECTRIC VANCOUVER WA98661 PV 0.0: GENERAL NOTES AND PROJECT DATA DS 07: WIRING SPECIFICATION PHONE:1-800-818-0598 9.984 KW AC MSP: EXISTING 225A WITH 200A MAIN BREAKER PV 1.0: PLOT PLAN DS 08: MOUNTING-DATA SHEET INFINITY SOLAR.COM MODULE TYPE& MPOSITE MODULE DIMENSIONS: (25)LIW/H)67.87"/444,4R 8 7 SH108 405M ROOF ASCE MATERIAL:-- 0 WI DSPEEDS: (30SEC GUST SIN INGLE PV 1.1: SITE PLAN DS 09: RACKING-DATA SHEET MPH) PV 1.2: ROOF SECTION DS 10: RACKING-GROUNDING OFFICE COPY REVISIONS INVERTER: (13)AP SYSTEMS DS3-L RISK CATERGORY I: 100 IM 1.0: INVERTER MAP DS 11: RACKING-CERTIFICATION Description Date Rev INTERCONNECTION METHOD: LINE SIDE TAP RISK CATEGORY II: 110 S 1.1: MOUNT DETAILS AHJ: CITY OF TIGARD RISK CATEGORY III-IV: 115 E 1.1: 3-LINE DIAGRAM GOVERNING CODES: ARRAY AREA: 21.04 SQFRACKING: GRASOL T RACKING 526.0 SQFTOR COMP ROOF E 1.3: WARNING LABELS Tf DS 01: PV MODULE SPECIFICATION SHEET , Icy;. 2010 OREGON SOLAR INSTALLATION SPECIALTY CODE � 'a ro 1 ili Signature with Seal 2022 OREGON STRUCTURAL SPECIALTY CODE(OSSC) a DS 02: COMBI MICROINVERTER SPECIFICATION SHEET ' , 2021 OREGON ELECTRICAL SPECIALTY CODE(NEC 2020) Approved plaa^.^ DS 03: COMBINER PANEL CERTIFICATION '�I 2022 OREGON FIRE CODE > DS 04: AC DISCONNECT UL CERTIFICATION shall be on job sit,. DS 05: AC DISCONNECT UL CERTIFICATION lip !DS 06: JUNCTION BOX UL CERTIFICATION PHOTOVOLTAIC NOTES: ���: �yia,i N 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL WITH THE"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING 4 4111111 t Project Name& DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK SYSTEMS. , iP�4 .,. Address ', y4 a' W UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING iii w U PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) CONSIDERATION OF a"P AND r"P BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE a Hctii b W 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC �" :" 0 THREAD-LESS COMPRESSION TYPE. LATERAL FORCE DETERMINATION. JI1 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB ro; q W lr 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. III'& fY fY DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS, 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR ` �� ., 0_ J o WITHSTAND THE WEATHER. * t � u'� DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE , ti N Iy Q Z N CD 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE �,h �1 > § � � Q APPROPRIATE WATER RUN OFF. AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A "�� s „ g N Z 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. „ O o BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW "'` \ 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS Z Q ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. ,m: r ; try `�I' @.�in;� W ci CC W 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.E 01,310.8 D) SATE L L TE VIEW Q 0 9.AJ UNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE DC SIDE OFPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 27. DING THE SYSTEM.(NEC 250.97)S ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE z � O VALIDITY OF PERMIT z WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF ' THE ISSUANCE OF A PERMIT \ Pv o.0 / SCALE:NTS q MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM.(NEC 690.34) SMALLER THAN#6 COPPER WIRE.(NEC 250.64 B) \ / Y 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BASED ON CONSTRUIGTIO } FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) DOCUMENTS AND /'' a %/,' ,°�A" k Q (CEC DATA SHALL NOT % . ,y//'',y,,, BE AVERT UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING-ELECTRIC SHOCK HAZARD. 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END. 250.64(E) r THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, Y yyi/ MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND(NECE 690.35(F)) A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED THE CODE OFFICI a , AfA /a, �%; 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER REQUIRING THE CO "/ / M0,14 " ' zoo, OF ORS/ ,/,Fq' // �;H % %u/°i /�i //, a+w FROM ANY PHYSICAL DAMAGE. Sheet Name NEC210.5. ERRORS. '//,/,,', ,/, ayry �eirg� SOUTHWEST £ VC° Ott, GENERAL NOTES 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. m/ ii/#� ,,#,/,y y a„ �a 10 4 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. 33.DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR '/ e;;x/ " ,%lip ° ,'y°� $ AND PROJECT 14.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER y y/r , ,/N �//,400, # - ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC 93.690.31(E) y arm / ,/, 1 e A- /' "/ TIN DATA 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, �",y,,/ 04144 i/" �,y(�j//aj COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED JUNCTION&PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S r /tt1f,%i tott,ti ! „a i t Sheet Size 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE INSTALLATION INSTRUCTIONS LAMC 93.690.110.3&93.110.3(B). cT of TTA* r eut ,t#„y f It , 4i y1%°,y� w / A ; ANSI B CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE REVIEWED T{)} C(.'I711i / � " " " ty ' e/ / .�" ' /i,���N�i�, BUtt'fvtp lMTA,N 11 11 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY STAINLESS STEEL LAMC 93.110.3(B). "'fi e,i'p4, '' , F j/" ! „ y ,, 11 X 17 ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICALApproved: # %i ` '/,a*,,fie'b '` �„'/y' 1, / 1,yeZ APPROPRIATE. EQUIPMENT SHALL BE PERMITTED TO A v Cd: /� e J 'i"��; ,*,,,4,,'" 'A'<,,%��t / /, %tot.,fig,�y. ��%Y, ' LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. Off' y„F//",,P7: �� �i,,y A� ,CAM yx,,,4 , � N,[ Sheet Number 18.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS ✓,„ ,/�,//,,�/,:", , a/r;: 1 r,,,,, y f," k/% 17',:: ,1tta� i�r,,V/S � � /'Klna1'IV �; I SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY Perm it , �,'�. " °% . '"/''�/ " ,, °'/� MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN REMOVABLE FASTENERS. U- �� 3' / jy ,/' ,/y� // PV O.O THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM 38.REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE a icl,:eSS: �/9router,/" F' �9/, �/� / '' REQUIRED BY THE ARCHITECT/ENGINEER. . , icy j /r'/yy'/� % ,y" " , '$BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAI(SLI i t e #: tt///i/z/i, / // "?' /t fi p/" t // ' 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. I� /yt y y // p , ,�//i --- OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING By: NA ,,t e yyy ��'�%F / A 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING -/ m 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE ROOF-COVERING MATERIAL. „��i b T "' / ,x � ti 40.ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM I/2"OFF THE ROOF SURFACE. 1 GENERAL NOTES AND PROJECT DATA EnVICINIT I 1 V AP PV 0.0 SCALE:NTS 0 ROOF MOUNTSYSTEM PHOTOVOLTAIC 25 MODULES-ROOF MOUNTED - 10.125 kW DC, 9.984 kW AC, 16549 SW DARWIN LP, TIGARD, OR 97224 mfinitysc lar INFINITY HOME SOLUTIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: OROOF ACCESS POINT VAN05E MILL WA98661 62'-9" PROPERTY LINE ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS PHONE:1-800-818-0598 SYSTEM SIZE: 10.125 kW DC w _.- - - _ - - - - - - - - -i THAT REQUIRE THE PLACEMENT OF GROUND LADDERS INFINITY SOLAR.COM 9.984 kW AC OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND MODULE TYPE&AMOUNT: (25)ZNSHINESOLAR ZXM7-SH108-405M LOCATED AT STRONG POINTS OF BUILDING REVISIONS MODULE DIMENSIONS: (LIW/H)67.87"/44.64"/1.18" w I ti CONSTRUCTION IN LOCATIONS WHERE THE ACCESS Description Date Rev INVERTER: (13)AP SYSTEMS DS3-L o I ED POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. AHJ: CITY OF TIGARD a 1 1 NEW PV AC DISCONNECT VISIBLE, 1, LOCKABLE, LABELED DISCONNECT I PATIO Signature with Seal WITHIN 10' OF UTILITY METER I 1 8'-7" ,i 1' 1 3'-8" 1 Project Name& ress U I FENCE z 1 wwo (7) 1 . I 1cc 1 11 ._.7.7 1 D go_ 0_ ___. ..4. 4_, I, ZN � Q co o > 2a; g c:, ! MAIN HOUSE IA ,i m ¢ O co Z co I' I W PP - I Z (08)ZNSHINESOLAR ZXM7-SH108-405M , ,., „„,q, z a SLOPE:36° 111. I AZIM.:270° 1 Q ROOF#3 > • EXISTING INTERIOR MAIN SERVICE I' I (06) ZNSHINESOLAR ZXM7 S H108 405M SLOPE:36° Sheet Name PANEL TIED TO EXTERIOR UTILITY ' I w AZIM.:90° METER#38 195 142 J PLOT PLAN OM ROOF ACCESS POINT I IV GARAGE GARAGE o Sheet Size 1 — J w"' ANSIB N I I � 11" X17" I L I DRIVEWAY I / Sheet Number A: N PV1.0 I LL - - - i - - _ _ l� - PROPERTY LINE 50'-0" 1 ROOF#2 FRONT OF HOUSE (11)ZNSHINESOLAR ZXM7-SH108-405M 1 PLOT PLAN 16549 SW DARWIN LP AZIOM.E:29° PV 1.0 SCALE:3/32"=1'-0" PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS MODULE, ARRAY WEIGHT(LOAD SYSTEM LEGEND SYSTEM SIZE: 10.125 KW DC NUMBER OF MODULES 25 ZNSHINESOLAR ZXM7-SH108-405M CALC'S) EXISTING INTERIOR MAIN SERVICE PANEL&POINT 0 9.984 KW AC NUMBER OF INVERTER 13 AP SYSTEMS DS3-L Number of Modules 25 I I OF INTERCONNECTION.TIED TO EXTERIOR UTILITY infinit 5 MODULE TYPE&AMOUNT: (25)ZNSHINESOLAR ZXM7-SH108-405M EATON BR STYLE 1-INCH LOAD CENTER METER#38 195 142. V solar MODULE DIMENSIONS: (UW/H)67.87"/44.64"/1.18" COMBINER PANEL 1 816L125RP Module Weight 45.19 LBS INVERTER: (13)AP SYSTEMS DS3-L Total Module(Array)Weight 1129.75 LBS NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS AC DISCONNECT 1 60A FUSIBLE AC DISCONNECT,240V ® LOCATED WITHIN 10' 6405 E MILL PLAIN AHJ: CITY OF TIGARD NUMBER OF ATTACHMENTS 89 GRASOL GS-10 RAIL ATTACHMENTS Number of Attachment point 89 FROM THE UTILITY METER VANCOUVER WA98661 Mounting System Weight PHONE 1-800-818-0598 RAILS 17 GRASOL RACKING SYSTEM (Per Module) 1.5 LBS © NEW DEDICATED PV SYSTEM COMBINER PANEL. INFINITY VISIBLE, LOCKABLE, LABELED DISCONNECT RAIL SPLICE 8 SPLICE KIT Mounting System Weight 133.50 LBS NS WITHIN 10'OF UTILITY METER MID CLAMPS 32 MID CLAMPS/UFO Total System Weight 1263.25 LBS 25 NEW ZNSHINESOLAR ZXM7-SH108-405M MODULES Description DateRev nwmleWdghr. ,naegsystemWagnry WITH NEW(13)AP SYSTEMS DS3-L INVERTERS. END CLAMPS 36 END CLAMPS/STOPPER SLEEVE ■ NOTE: Weight at Each Attachment Point GROUNDING LUG 9 GROUNDING LUG (Amoy Weghd/Number of Machined Pant) 12.69 LBS ATTIC RUN-YES Module Area(67.87"x44.64") 21.04 SqFt ATTIC FAN NO Total Array Area 525.99 SqFt } ,I =FIRE PATHWAY SHUTDOWN-NO Distributed Load (radSystem Weght/ToteMeyArea) 2.22 Per SqFt Signature with Seal DO =ROOF OBSTRUCTIONS Total Roof Area 2453 SqFt Total Percentage or Roof Covered o } rasa eya ee/reteReefAeo)"100 21.44/o • =ATTACHMENT POINTS =RAFTER ❑ ❑ Project Name& Address =RACKING SYSTEM W i-: — = ATTIC RUN 0 U3 W CC X =CONDUIT ATTIC RUN JUNCTION BOX %/ o g Z v n y — ti %' hi � I ROOF SECTIONS a o o Li E ��, l 1 I I I I ROOF not MODULE 08 W N o V ��� O 12"FIRE SETBACKS z,, , V� SLOPE-36° CC rn Q w wo %/❑ i>/ 1/ �/ Z AZIMUTH-270° Q v CO Z ���/ "*�/- 1 1 I I / w MATERIAL-COMPOSITE SHINGLE z co ~ O /❑ 0 12 FIRE SETBACK ',�i% 2 RAFTER SIZE&SPACING 2"X4"@ 24"O.C. � �/ ——— — `i /mil i i r /�//� �, U ROOF#02 MODULE 11 g N / i/i it�or�� /i// //��i��� e. —— 1- o / _ SLOPE-29° Y �/❑ A/.97/ ' r < _ Q AZIMUTH-180° �� �r� -- ❑v / >/ / cv > Q MATERIAL-COMPOSITE SHINGLE Q0-v1%i,� /0 m '/�/�� /////.%// e/W E` RAFTER SIZE&SPACING-2"X4"@ 24"O.C. ✓'�/�' w ,0-/r/////l/f/ / cwi�`:����� �� w ROOF MODULE-06 '� � y '��, % w'(./: Z tr03 SLOPE 36° ' /�// % % %� �� Sheet Name .f4,///'//, — %�% � �`.;. .°Si, / AZIMUTH-90° NEW AC COMBINER PANEL ✓/� /�/ i // /// A LTt ,b r/% MATERIAL-COMPOSITE SHINGLE ;� %"j/ �:. /i. ///�� %� RAFTER SIZE&SPACING 2"X4" 24"o.c. SITE PLAN NEW PV AC DISCONNECT GROUPED ✓� `�'� f�//��7,'/, � ' / WITH SERVICE EQUIPMENT(VISIBLE, ��P 0 � '////% LOCKABLE,LABELED /� � `' 1 //I �� V Sheet Size i/// i,///, ANSI B EXISTING INTERIOR MAIN SERVICE PANEL /� __ ____ � &POINT OF INTERCONNECTION.TIED TOCSD „� 11" X 17" EXTERIOR UTILITY METER#38195142 O --i NOTE:- ROOF#02 _J ROOF ATTACHMENTS SHALL BE SPACED NO Sheet Number GREATER THAN 24 IN.OC IN ANY DIRECTION N PV 1.1 I WHERE LOCATED WITHIN 3FT. OF A ROOF NOTE: - EDGE, HIP, EAVE OR RIDGE(OSISC 305.4.3) ALL PLUMBING AND FLAT VENT WILL EID CIRCUIT BE RELOCATED OR REMOVED PRIOR TO (S) INSTALLATION FRONT OF HOUSE 6549 SW DARWI N LP V/ /CIRCUIT#1 -08 MODULES WITH 04 MICROINVERTERS 1 SITE P LAN V/ /Ai CIRCUIT#2-09 MODULES WITH 05 MICROINVERTERS Pv1.1 SCALE:1/8"=1'-0" %////// CIRCUIT#3-08 MODULES WITH 04 MICROINVERTERS ROOF 1 ' WESTSIDE (N)PVMODULE i_6., 2"X4"TRUSS@24'O.C. in11�1it�/SC3lt 1i INFINITY HOME SOLUTIONS tiiiiislis 0 6405E MILL PLAIN J,_os -'1'_p` VANCOUVER WA 98661 NE:1-800-818-0598 " 10'-6" INFINITY SOLAR.COM T 4" T 4" REVISIONS '6 _0` §-O‘ Description Dale Rev 29,0° ' c ---10'-4"- 10'-0" 10'"p" -- 1 p t�l' .11.117a .11.MMIMIIMIIIM"Mil .Mir Signature with Seal ROOF SECTION EXTERIOR BEARING WALL EXTERIOR BEARING WALL Project Name& Address W U (NI PV MODULE 0,4 -- g,�„ z LJJ ROOF 1 o u) EAST SIDE 2'X4"TRUSS@24'O.C. W (N)PV MODULE N L .00000.00,0 Nct NQx/r, Z I o 0 0 L �'_q‘ �J�' z Q 4'B" 4)" rn Q W W 2910° 29;0° Z H 0O co x 4-4"- 1---- ---T_4" ---1- 7'-8"- y- 7'-8"- T-4" _ --8_4_ _ Y Q \\ ROOF SECTION > `-EXTERIOR BEARING WALL EXTERIOR BEARING WALL J/// Sheet Name V' M ROOF SECTION §', --, r '-2" Sheet Size ROOF 1 2"X4'TRUSS@24"0.C. 2"X4'TRUSS@24'O.C. ROOF 3 Z-4f /., / 3 4, ANSI B (N)PV MODULE -, l I (N)PVMODULE 11" X 17" 10'-6° 10-6" � �0 Sheet Number 1610 " 6'-)0" 0" 5'-0" PV 1.2 36.0° —---f>'-4" 1--2'-0"--�---4'-0"----' ---4'-0"----"---2'-0"--1-----6'-4" ROOF SECTION ROOF SECTION CI) ROOF SECTION EXTERIOR BEARING WALL EXTERIOR BEARING WALL N 0.1 1 13 infinity solar INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 INFINITY SOLAR.COM 2 14 REVISIONS Description Dale Rev 3 15 Signature with Seal 4 16 Project Name& U Address 5 1 Z W _ a CC 6 18 a a o Z N tC� CV CO cr..; N 7 19 a 000Li w < w w < 1 O CD 8 20 5 9 21 Sheet Name INVERTER MAP 10 22 Sheet Size ANSI B 11"X17" 11 Sheet Number 23 IM 1.0 12 24 �10 INVERTER MAP DTU/ECU: \M 1. GENERAL STRUCTURAL NOTES: PV MODULE 0 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE GRASOL RACKING SEE(2/S 1.1) FORinfinity solar SYSTEM WITH GRASOL GS-10 MOUNT ENLARGED VIEWINFINITY HOME SOLUTIONS ATTACHMENTS. THE MOUNTING FEET ARE TO BE 10000000000000000.0000000•01"............1 6405 E MILL PLAIN VANCOUVER WA 98661 SPACED AS SHOWN IN THE DETAILS, AND MUSTBE STAGGERED TO ADJACENT FRAMING / PHONE:1-800-818-0598 INFINITY SOLAR.COM MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. REVISIONS 2. UNLESS NOTED OTHERWISE, MOUNTING • �SgES @24"OC ANCHORS SHALL BE 1/4" LAG SCREWS WITH A Description Date Rev MINIMUM OF 3" PENETRATION INTO ROOF 21-4 - FRAMING. 3. THE PROPOSED PV SYSTEM ADDS 2.5 PSF TO THE °; / (E)COMPOSITE SHINGLE ROOF ROOF FRAMING SYSTEM. / 4. ROOF LIVE LOAD=20 PSF TYPICAL,0 PSF UNDER 0.0 N Signature with Seal NEW PV SYSTEM. / 5. GROUND SNOW LOAD=N/A PSF 6. WIND SPEED=110 MPH 1 7. EXPOSURE CATEGORY=C 8. RISK CATEGORY=II Project Name& Address w U z w 0 ' ATTACHMENT DETAIL (SIDE VIEW) w ct \s 1 1 SCALE:NTS a a o J Lo Z CV LO CV ch � wo� N Z SOLAR MODULE o � � o z � o --a , / .1 CC 0) ¢ iuw zLLn H- O GRASOL GS-10 RAIL z -- a Y Q Sheet Name GS-FK-02 305MM ROOF FLASHING MOUNT DETAIL /. Sheet Size BUILDING STRUCTURE ANSI B 11" X 17" Sheet Number ROOF S 1.1 1/4"X 3" SS LAG SCREW 2.5" MIN. EMBEDMENT 2 \ ATTACHMENT DETAIL ENLARGED VIEW s11 / SCALE:NTS PV MODULE RATING @ STC MICROINVERTERS SPECIFICATION Rooftop conductor ampacities designed in compliance with THIS PANEL IS FED BY MULTIPLE SOURCES MANUFACTURER ZNSHINESOLAR ZXM7-SH108-405M MICROINVERTER MAKE AP SYSTEMS art. 690.8, Tables 310.15(B)(2)(a),310.15(B)(3)(a), (UTILITY AND SOLAR) 3 MAX.POWER-POINT CURRENT(IMP) 13.03 AMPS MICROINVERTER MODEL NO. DS3-L 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, &9. MAX.POWER-POINT VOLTAGE(VMP) 31.10 VOLTS MAXIMUM AC OUTPUT 768 W Location specific temperature obtained from ASHRAE 2017 AC OUTPUT CURRENT 42A infinity SClar MAX INPUT VOLTAGE 60 V data tables INFINITY HOME SOLUTIONS OPEN-CIRCUIT VOLTAGE(VOC) 37.30 VOLTS MAX AC CURRENT 3.20 A NOMINAL AC VOLTAGE 240V 6405E MILL PLAIN SHORT-CIRCUIT CURRENT(ISC) MAX OUTPUT VOLTAGE 240 V VANCOUVER WA 98661 13.77 AMPS RECORD LOW TEMP -19°C 120% RULE PHONE 1-800-818-0598 NOM.MAX.POWER AT STC(PMAX) 405 WATT AMBIENT TEMP(HIGH TEMP 2%) 33°C ° INFINITY SOLAR.COM VISIBLE, LOCKABLE, LABELED DISCONNECT BUS BAR RATING X 120/o) - MAIN BREAKER RATING MAX.SYSTEM VOLTAGE 1500V WITHIN 10'OF UTILITY METER CONDUIT HEIGHT 0.5n = MAX. PV OCPD REVISIONS Description Dale Rev VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 55°C (225A x 120%) - 200 = 70A NOTE : - ATTIC RUN-YES CONDUCTOR TEMPERATURE RATE 90°C 25 ZNSHINESOLAR Z - SHUTDOWN-NO POINT OF INTERCONNECT,SUPPLY SIDE ( ) XM7 SH108-405M MODULE: (25)ZNSHINESOLAR ZXM7-SH108-405M EXISTING 240V/225A BUS BAR RATING, Signature with Seal (13)AP SYSTEMS DS3-L INVERTERS INVERTER: (13)AP SYSTEMS DS3-L MAIN SERVICE PANEL,SINGLE PHASE, BRANCH 1-08 MODULES WITH 04 MICRO INVERTERS WITH A 200A MAIN BREAKER • mom moms """ I I mom I I mom■■ UTILITY COMPANY-PORTLAND I mom mom I mom moom I I •••••• I I mom•■ mommommomo GENERAL ELECTRIC momI now mom 1 1 mom 1.■■■■, mom 1■■■■■ moms'•••••1 moms mow I•••••! mom UTILITY METER#38 195 142 1■■■■■1 mom1■■■■■1 mom mom moms 1■■■■■1 ■■■■■■ ■t■■■■1 ■■■■■■ 1.■■■■I MEWf.■■■■I ■■■■■■ ,•••••1 LINEMEN! '■•■••1 LINEMEN! '••••• ■■■■■! •.■■■■1 •••••N EXISTING Project Name& !■■■■■! BI-DIRECTIONAL w Address L_ _J L_ _J L J L� _ J UTILITY METER, _ �J LINE SIDE TAP (N)BLADE TYPE - L L 1! I",/1 (N)125A COMBINER PANEL, FUSIBLE AC DISCONNECT 1-PHASE,3W, 7 240V,3W,1-PHASE NEMA 3R 60A-2P 120/240VAC USING IPC 120V/240V BRANCH 2-09 MODULES WITH 05 MICRO INVERTERS (VISIBLE,LOCKABLE, LABELED) w m.■■■■1 m■■■■■1 ■■.■■■ I■■■■■1 ■■.■■■ '■■■■■l ■■■■■■ M■■■■■1cC MMENEM.■..■1 '.■a■1MENEM 1■■■.■1 I.....1 t■■■■■1 60A FUSES u■■■■1 umn ■o■■■ � •■momo■■■ n■■■nIMMESH ■om n■■ol mom 200A E { CL -_ v 21 1 •i..■■.1 mom1...■.1 mew1.....1 mu. 1■...■1 m■■■.■1 •.....1 .■■■.. mom ■■■■■■ 1■....1 um. 1■■■■■I I imam oo■■ mom o■■o mon ■■■■■■ mowmom mom I I momI I momI I mom (N)JUNCTION BOX ° • • Q N (2) !mom! !mom! ■■m■ ! ! ■■m■ ! I mom ! ! o■■■■ 600 V,NEMA 4 ° (E)LOADS > rn N Q UL LISTED 20A o ¢ cc CD z mem L J L- ® _J L== _J L- ® ,J p O o •J Zvi / / ,h,, �_ r E E 0 20A -S •• i LZ Q L J. ° L1 n (E)LOADS CL Q v (9a L2 L2 BRANCH 3-08 MODULES WITH 04 MICRO INVERTERS 20A ° -0: . Z co j O Lt L1 Z '- d �■■■■■I �■■■■■1 1■■■■o ■■■■■■ ■■■■■ ■■■■■■ I 0 I -0• I■■■■■1 ■■.o■ 1■■■■.1 ■■■■■■ M.■■■.1 ■■■■■ ■■■■■■ L2 L2 ° I■■■■.1 ■■.■■■ 1■■■■■1 ■■■■■■ 1■■■■.1 ■■■■■ ■■■■■■ I:::Ca ••UU U ......i ••U• • IU••Ui ■■■■■■ UU••• ••••UU L, L1 N_ Y �■■■.■1 I■....1 ■■■■■■ M■■■■■1 ■■■■■ N M..1■n M.■.■■1 n■..■1 _.._.._ U , i.....1 ■■■■■■ i.....1 ■■■■■■ i.....1 ■■.■■. ■■■■■. ] L2 G __. _.... _... __ ___ N �- !o■■y ■■■o■ no■y ■■■■o !moot ■■■o■ o■■■■ G r-- , Q --� - c I (�' I } I I G 5 ,/,,/ I I i1\I 1f".J Q I -1- L L 1 1 J Sheet Name O @ (3) © EXISTING GROUNDING 3-LINE ELECTRODE SYSTEM DIAGRAM Sheet Size ANSI B WIRE MAX PARALLEL C.0 PV CURR. TOTAL CONT. CURR WIRE TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE 11" X 17" TAG# DEVICES RATING MULT CURR X 125% WIRE SIZE\TYPEWMP. OCP #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) Sheet Number O 05 x 3.20 x N/A = 16.00A 20.00A #10\THWN\40A @90°C 20A 2 TRUNK CABLE 0.96 x 1.00 x 40A 38.40A 16.00A #6 AWG 20 0.28 IN AIR E 1 .1 O05 x 3.20 x N/A = 16.00A 20.00A #10\THWN\40A @90°C 20A 6 3/4" EMT 0.96 x 0.80 x 40A 30.72A 16.00A #8 AWG 6 1.33< 5 0.90 2 0 13 x 3.20 x N/A = 41.60A 52.00A #6 \THWN\65A @75°C 60A 3 3/4"EMT 0.94 x 1.00 x 65A 61.10A 41.60A #8 AWG 10 0.15 SITE NOTES: GROUNDING NOTES: 1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND 0 REGULATIONS. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH infinity solar 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A USE. UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM INFINITY HOME SOLUTIONS 6405E MILL PLAIN 3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, NEC TABLE 250.122. VANcowERWA98661 OR BUILDING ROOF VENTS. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES PHONE:1-800-818-0598 INFINITY SOLAR.COM 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC REVISIONS 5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. Description Date Rev ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE BUILDING OR STRUCTURE. NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURER'S INSTALLATION EQUIPMENT LOCATIONS: REQUIREMENTS. Signature with Seal 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES ANOTHER MODULE. 310.15(B)(2)(A)AND 310.15(B)(3)(C). 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] ACCORDING TO NEC 690.34. 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 Project Name& 4. ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A LLI Address 1 WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 z INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC _ AND AHJ. APPLICABLE CODES. 9. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO Jo 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR REDUCE FIRE HAZARDS w Iz USAGE WHEN APPROPRIATE. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: CL a 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS Z c - 'to 9STRUCTURAL NOTES: OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE m Z a' N z 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS). ¢ I� cfl CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE a 0 O o Li SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH w d t" BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAILS 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID v cal w w MANUFACTURER'S INSTRUCTIONS. SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY < in ( O 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). Z to a ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND �d REQUIREMENTS. 240. Y 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ 5. MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED >- Q APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. FUSES IN ACCORDANCE WITH NEC 110.3(B). 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION > SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN ACCORDING TO NEC 690.11 AND UL1699B. POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED Sheet Name AMONGST THE ROOF FRAMING MEMBERS. INTERCONNECTION NOTES: NOTES 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12(B)] WIRING&CONDUIT NOTES: 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. EXCEED 120%OF BUSBAR RATING[NEC 705.12(D)(2)(3)]. Sheet Size CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT ANSI B REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL 11° X 17" 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED 3. VOLTAGE DROP LIMITED TO 1.5%. BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE Sheet Number 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING UTILITY SOURCE OCPD[NEC 705.12(B)(2)(3)]. SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL E 1.2 WIRING CLIPS. RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED PHASE B OR L2-RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- ACCORDING TO NEC 705.12(B)(2)(3)(C). BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL-WHITE OR GREY 5. FEEDER TAP INTERCONECTION(LOADSIDE)ACCORDING TO NEC 705.12(B)(2)(1) IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH BE MARKED ORANGE[NEC 110.15]. SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(B)(5)]. A ..._ ELECTRICAL SHOCK HAZARDc)(1 infinity solar TERMINALS ON BOTH LINE AND LABEL LOCATION: --► PRODUCTION/NET METER(BI-DIRECTIONAL) INFINITY HOME SOLUTIONS LOAD SIDES MAY BE ENERGIZED NEC:2020 6405 E MILL PLAIN VANCOUVER WA 98661 IN THE OPEN POSITION _ _ _ NEC 690.59,705.12(D)(3) PHONE:1-800-818-0598 INFINITY SOLAR.COM LABEL LOCATION: LABEL LOCATION: WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE \ REVISIONS ENERGIZED IN THE OPEN POSITION,A WARNING SIGN SHALL BE \ NEC:2020,705.12(B)(3)(2) Description Date Rev MAIN SERVICE DISCONNECT MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. PER CODE(S):NEC 2020: NEC 706.15(C)(4)and NEC 690.13(B) I PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 41.60 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS Signature with Seal LABEL LOCATION: LABEL LOCATION: MAIN SERVICE DISCONNECT,NEC 2020,690.13(B) I AC DISCONNECT,POINT OF INTERCONNECTION NEC:2020 J (PER CODE:NEC 690.54) II Project Name& C LABEL LOCATION: Address W PERMANENT WARNING LABELS SHALL BE APPLIED TO U 1 DISTRIBUTION EQUIPMENT,AC DISCONNECT 1 Z NEC:2020 I CAUTION : Q PER CODE:705.12(B)(3)(3) I POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE CT) w FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS a PHOTOVOLTAIC SHOWN. N 12 DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES > - Q AC DISCONNECT SOLAR PV SYSTEM q a C Z 0 O o EQUIPPED WITH RAPID17j a g Li LABEL LOCATION: SHUTDOWN11 �` '', AC DISCONNECT W Z Q 0, Q W W NEC:2020 Z < et 0 Z (NEC 690.13(B) X TURN RAPID Z 1= O m 0 SHUTDOWN Z a a m SWITCH TO THE PHOTOVOLTAIC SYSTEM oo OFF POSITION TO SOLAR Y SHUTDOWN PV ELECTRIC J PV PANELS EQUIPPED WITH - i SYSTEMA _z >- SHOCK HAZARD =Id RAPID SHUTDOWN IN THE ARRAY Sheet Name AT INVERTER(IFC 605. . .1131(1)&690.56(C)] Q LABEL LOCATION. PER CODE:NEC 2020 WARNING UTILITY SERVICE ENTRANCE/METER,INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS LABELS REQUIRED BY LOCAL AHJ. PER CODE(S):NEC 2020:ARTICLE 690.56(C) Sheet Size PV ARRAY1- if) ANSI B 11"X17" CD Sheet Number # JIB A E 1.3 I + I L _ — — - SOLAR PHOTOVOLTAIC �— M I- — -I I SYSTEMS C1AC O 25 PV MODULES I I I (PER CODE:NEC 690) MAIN SERVICE PANEL WARNING:PHOTOVOLTAIC -_ _ _L _ J _ J AC COMBINER PANEL POWER SOURCE L- AC DISCONNECT UTILITY METER LABEL LOCATION: SOLAR PHOTOVOLTAIC EXPOSED RACEWAY,CABLE TRAYS,JUNCTION BOX SYSTEMS NEC:2020,PER CODE:NEC 690.31(D)(2) (PER CODE:NEC 690) ZNSHINESOLAR [[f{!1 AApp 0 ZXM7- H1 Series,, Znshinesolar 1OBB HALF-CELL Black LNSf1�NG3L1�H 1 tag j('�� �� Z��11���.#Ll��R 1 Monocrystaltine PERC PV Module infinity C1( INFINITY HOME SOLUTIONS 6405 E MILL PLAIN DIMENSIONSOF �j0(}tJji9m) VANCOUVERWA98661 1 rie I.V CURVES OF PV MODULE(400W) PHONE 1-800-818-0598 sem INFINITY SOLAR.COM to Ceps tamp=25'C ,o- Incident nad.=1000w1m' REVISIONS earcode 1 30+1 -- - - i II 3._.".._. _- --- -- "-.--` "- imxenumaa-eoo wrm• Description Date Rev ... ie-era eawee t i-'i a incident 600 wrm• i 111111111IllIIllllllllllllllillllflllll1i11! �t � 1i11111�iII11�IWIlilUl�11�1lIlIIIIIHIII! 1 BBB HALF-CELL L Black MC3110C 5 � 11 0 PERC PV Module le IINIIII.iIIIIINIIIIIlJU1ll lllNtill1Elll 1111111(�1111111lll�lllllll!!llllllllllllllhlllll!!li" I, ,/ - n�em Wed s4adwm° 1111111i111lIII�IIf Ill - I-� 4 i r endrad.=200WOW I11111111lI*HIIIIIIPl11161Jl111I1111 • llilllll lllI1I1111111I1llllllll191UI!! ! d s e 5 Signature with Seal I�,l10� if 111�> icjiiri-ID - r- Voltage[V] 1 51 Juncpm box/ o a Illlllll�1111I 11111I1lllllllll111111i111 I _ P-V CURVES OF PV MODULE(400 390-410Wz0.97/a �•�� to 111011111111111l11111111illlll111 Cella terry 2SC POWER RANGE MAXIMUM EFFICIENCY YEARLY DEGRADATION 11I11III1i11IWI111IIIIi111111111I11I111IIII f i � t2naa-,�w,� IIlI1I111I1oaIII1111I11111111i111hIIlll :! ^1; !A _ -I^ had= Wind (kklllll �__� -Incident hood 200 Ware C+anbnB Incident Irrederat_200 wren' i. I I 1[II I I Ill 1/aW,mmta �^- Project Name& 1 II I I I I 1 •, •j m Address 2 12 YEARS PRODUCT WARRANTY �� 25 YEARS OUTPUT GUARANTEE d11111li111111IIIl111lllllplillllpllll111_, y no- w - us1_s a U �-� Z iimiim tIlfks t)£a tyls3 l ; da °t Front View Back View w l �t '{ n �d s n w a a ) ai / 'aema k:eustemized fro re color and cabin Length avallanle upon request afN el" C C PV CYCLE voltage[Vj N Zoehine Standard c US NOW 1..r_ Common Standard D iiii- 100/ a_ C7 p �\\\\�\� IEC 61215/IEC 61730l IEC 6170171EC 62716/UL61730-1/UL 61730-2 a. dui �\\\\� ��`\�� �\\'\a\\ J N � so t400l Environmental Management system ELECTRICAL AL CHARACTERISTICS STC° MECI to ICAL DATA � v �� CD L° � A ISO 9001:Quality Management System Z c9 80% I5045001:occupational Health and Safety Management System Nominal Power Watt Pmax(W)' 390 395 400 405 410 Solar cells Mono PERC � r � 0 CI O J 1 5 12 15 Years .. - r t fy u , k �,la.< r,,a r n ,_a.< _,,,,..., t.,t. .sec,c<� .t.�..-s Maximum Power Voltage Vmp(V) 30.50 30.70 30.90 31.10 31.30 Cells orientation 108(6x18) Z Q I f .li L t 1P .,.� 3tity nY,c.`,K agpI.a.err F_ ell,: =.,,Js peee 14 is proci,,,ar to 6e ere, of 3 e:i ny Z2151INE PJ TEC,Ca.1,r) LIJ N Maximum Power Current Imp(A) 12.79 12.87 12.95 13.03 13.10 Module dimension 1724.1134.30 mm(With Frame) Q W W Z u i= O CO m Open Circuit Voltage Voc(V) 36.70 36.90 37.10 37.30 37.50 Weight 20.5±1.0 kg z O_ FKEY T Short Circuit Current Isc(A) 13.56 13.63 13.70 13.77 13.84 Glass 3.2mm,High Transmission,AR Coated Tempered Glass g P- Better Weak Illumination Response Module Efficiency(%) 1995 20.20 20.46 20.72 20.97 Junction box IP68, 3 diodes Q ,i11 ill, Excellent Cells Efficiency P 7 a o w.f., ly and the I<a" n p:. t.. 1 -y ipeg > I -c ow n M- TE r. AM Cables 4 mm',350 mm(With Connectors) MBB technology reduce the distance between busbars and More power output in weak light condition,such as haze, 3>> a r.g.,. ,,i.F-etectre'lcha aril...;c,mch dc Fun ,.nit ere rote,k3, me_ finger grid line which is benefit to power increase. cloudy,and early morning. Connectors MC4-compatible Sheet Name *Pleas,erertor.:,naida t.I,.., d:-nrectw PV MODULE ELECTRICAL CHARACTERISTICS I NMOT TEMPERATURE RATINGS° WORKING CONDITIONS SPECIFICATION - ) Anti PID 0 Adapt To Harsh Outdoor Environment Maximum Power Pmax(Wp) 291.50 295.20 299.00 302.70 306.30 NMOT 44°C s2°C Maximum system voltage 1500 V DC SHEET ' Ensured PID resistance through the quality control of cell Resistant to harsh environments such as salt,ammonia, sand,high temperature and high humidityenvironment. Maximum Power Voltage Vmpp(V) 28.30 28.50 28.70 28.90 29.10 Temperature coefficient of Pmax -0.35%/°C Operating temperature -40°C-+85°C Sheet Size manufacturing process and raw materials. 9 P 9 Maximum Power Current Impp(A) 10.29 10.35 10.41 10.47 10.53 Temperature coefficient of Voc -0.29%/°C Maximum series fuse 25 A ANSI B TIER 1 *✓ Excellent QualityManagerment System Temperature coefficient oflsc 0.05061°C Front Side Maximum Static Loading Up to 5400 Pa 11" X 17" 9 Y Open Circuit Voltage Voc(V) 34.30 34.50 34.70 34.80 35.00 P Global,Tier 1 bankable brand,with independently certified Warranted reliability and stringent quality assurances well Rear Side Maximum Static Loading Up to 2400 Pa Sheet Number Short Circuit Current lsc(A) 10.95 11.01 11.06 11.12 11.18 er,a,,tx ull,rar..z r.Comorosg«x tete.moerr,d> ,o- y iau-c-rce:>x,n advanced automated manufacturing, beyond certified requirements. a_ ke t ii 111l:t a y r lith,o;ah eaaholrrleoffer- DS 01 tiM1UJT;^rya�e 8il0.:-m'S en eTvE ..i�%0°C.�A 1.i,Nind Speed`;.,.- . . Ilteyuttr,ere'o orntas ra.ry,lferent rrocuetypes. rCauton PIrsqe no kuollyssivsorithut PI,'mod osd 55 needled aerdr,_a( t s1t ,p'•e-..0 have c'ar st a,n.6 PACKAGING CONFIGURATION ere.r_3 r,emits Tad te,acry ,d:-tst .,recur sbet,Busing taIraVeaxlutro . ............. ��i. Improved Aesthetics 3 Piece Box 36 ¢- Compared to conventional modules,this full black modules Piece/Container(40'HQ) 936 have a more uniform appearance and superior aesthetics. , 'Costonvz5d p.-skayru}Laveleabie upon request Founded in 1938,ZNShine solar Is a world`s leading high-tech PV module manufacturer.With the advanced production tines,the company boasts module 9 Add:1#,Zhixi Industrial Zone,JintanJiangsu 213251, P.R.China Tel: .86 519 6822 0233 ® E-mail: info@zashinesotar.com capacity of 6G'W.Bloomberg has listed ZN5hine as a global Tier 1 PV module maker.Today Znshine has distributed its sates to more than 60 coantries around the lobe. Note:Specifications included in this datasheet are subject to change without notice.ZNSHINE reserves the right of final interpretation©ZNSHINE SOLAR 2022 I Version:ZXM7-SH108 2202.E g wvvw.znshjnesotar.com No special undertaking or warranty for the suitability of special purpose or being installed in extraordinary surroundings is granted unless as otherwise specifically committed by manufacturer in contract document 0 APsyste s Leading the Industry in Datasheet I DS3 Microinverter Series infinitysoiar INFINITY HOME SOLUTIONS 411 ALTENERGY POWER Solar Microinverter Technology 6405 E MILL PLAIN VANCOUVER WA 98661 ModelC)r�, _ DS3-I DS3 PHONE:1-800-818-0598 INFINITY SOLAR.COM Input Data(DC) REVISIONS ■ Recommended PV Module Power(STC)Range 250Wp-480Wp+ 265Wp-57OWp+ IOOWp-660Wp+ • DS3 Seri �scn hon Peak Power Tracking Voltage 22V 48V 25V-55V 32V-55V P Date Rev Operating Voltage Range 16V-60V 16V-60V 26V-60V The most powerful Dual g ' Maximum Input Voltage 60V t(({{tt u •o n .t r Maximum input Current 16A x2 18A x 2 - 20A x 2 (30t Signature with Seal • One rnicroinverter connects to tvvo solar modules pO t Data (AC) i. - Max output power reaching 640VA,768VA or 880VA Maximum Continuous Output Power 640VA 768VA 880VA Two independent input channels(MPPT) Nominal Output Voltage/RangeA 240V/211V-264V • CA Rule 21(UL1741 SA)compliant Nominal Output Current 2.66A 3.20A 3.7A • NEC 2020 690.12 Rapid Shutdown Compliant Nominal Output Frequency/Range 60Hz/59.3Hz-60.5Hz • Encrypted Wireless ZigBee Communication Power Factor(Default/Adjustable)' Project Name& • Phase Monitored and Phase Balanced 0.99/0.7 feading...0.7 lagging Maximum Units per 20A and 30A Branches 6/9 5/7 4/6 U Address AC Bus Cable 12AWG/IOAWG Z W Efficiency CI LLI Peak Efficiency 97% fY CEC Efficiency 96.5% LO PRODUCT FEATURES Nominal MPPT Efficiency 99.5% a v Z N LO Night Power Consumption 20mW Q N to rn CNI APsystems 3nd generation of dual microinverters are reaching unprecedented power outputs of 640VA or 768VA or 880VA to adapt to today's Q cn larger power module. With 2 independent MPPT, encrypted ZigBee signals, the DS3-S, DS3-I. and DS3 benefit from an entirely new Mechanical Data 0 Q 0 O _J architecture and are fully backwards compatible with the QS1 and YC600 microinverters. Operating Ambient Temperature Range -40°F to+149°F(40°C to+65°C) Z . Q LLI CA CC i The innovative and compact design make theproduct lighter while maximizingStorage Temperature Range 40°F to+185°F CC < Z W p g g power production.The components are encapsulated with (-40°C to+85°C) v- silicone to reduce stress on the electronics,facilitate thermal dissipation,enhance waterproof properties,and ensure maximum reliabilityof the Dimensions(W x H x D) _ 10.3"x 8.6"x 16"(262mm X 218mm X41.2mm) Z m F— O system via rigorous testing methods includingaccelerated life testing. A 24 7 energyaccess through Z d g / g Apps or web based portal facilitate Weight 5.71bs g) remote diagnosis and maintenance. g (2.6k DC Connector Type Staubli MC4 PV-ADBP4-52&ADSP4-52 Y Cooling Natural Convection-No Fans spikes in the grid. With a performance and an efficiency of 97%, a unique integration with 20% less components,APsystems DS3-S, DS3-L Enclosure Environmental Rating Q NEMA 6 and DS3 are a game changer to residential and commercial PV. -, Features Communication(Inverter To ECU)® Encrypted ZigBee Sheet Name MICROIsolation Design High Frequency Transformers,Galvanically Isolated SPECIFICATION R WIRING SCHEMATIC Energy Management SPECIFICATION BY g Energy Management Analysis(EMA)system Warranty® 10 Years Standard;25 Years Optional SHEET 4--iiii Sheet Size - - 1 mom 1•■■■■■■■■' Compliance . . 1■■■■■■■■ ANSI B ■■■■■■■■ Safety and EMC Compliance U1.1741;CSA C22.2 No.107.1-16;CA Rule 21(UL 1741 SA);FCC 11 n X 17" . I■u■■■■■■ Part15;ANSI C63.4;ICES-003;lEEE1547;NEC2014&NEC2017 Section 1■ ■■■■■■ i _ ■■■■■■■■ 690.11 DC Arc-Fault circuit;Protection NEC2014&NEC2017 Section ■■■■■■■■ Sheet Number ■�����■� 690.12 Rapid Shutdown of PV systems on Buildings;NEC 2020 — ��o■■■■■ �''�}` ��, �- _ .` __ �1■■ 0 Nominal voltage/frequency range can be extended beyond nominal if required by the utility. ®All Rights Reserved D S 02 �:; ` _�i r t ��� ci Limits may vary.Refer to local requirements to define the number of microinverters per branch Specifications subject to change without notice please ensure you are using the s _ 1 t r in your area. most recent update found at web:vsa.APsystems.com „,,,„„ [ 1 A�104 �3 Recommend no more than 80 inverters register to one ECU for stable communication. j[_-' � To be eligible for the warranty,APsystems mtcrornverters need to be monitored ',� p =� �,. via the EMA portal.Please refer to our warranty T&Cs available on usa.APsystems.com. APsystems Meets the standard requirements 600 Ericksen Ave NE,Suite 200 Seattle,WA 98110 4�® for Distributed Energy Resources Tel:844-666-7035 (UL 1741)and identified with the apsystems.com c us CSA Listed Mark 2022/02/15 Rev1.3 infinity solar E L T.N INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA PHONE:1-800-818-0598 Powering Business Worldwide 8661 pe.eaton.com INFINITY COM REVISIONS Description Date Rev BR style 1-inch Ioadcenter `'' Signature with Seal BR816L125RP �' E r UPC:786676001472 Dimensions: �€ �� , � 1 Project Name& Height: 13IN ... �.. ,,,4,I�a. .. Address • w • Length: 3.56 IN Uw • Width: 11 IN w Warranties: ct • 10 year a o J 11� Specifications: Z CNI CO n "' • Special Features: Current design > 63- C z • Type: Main lug 0 w 0 Li • Amperage Rating: 125A w 0 o 'Li • Box Size: 7r , cC 6, adiw • Bus Material: Aluminum z C LO ~ o CO � • Cover: Cover included z • Enclosure: NEMA 3R • Enclosure Material: Metallic } • Interrupt Rating: 10 kAIC a • Main Circuit Breaker: BR • Number Of Circuits: 16 Sheet Name • Number Of Spaces: 8 COMBINER PANEL • Number Of Wires: Three-wire CERTIFICATION • Phase: Single-phase Sheet Size • Voltage Rating: 120/240V • Wire Size: #14-1 AWG Cu/AI ANSI B 11" X17" Supporting documents: • Eatons Volume 1-Residential and Light Sheet Number Commercial DS 03 • Cutler-Hammer Type CH and BR Loadcenters - Instructions • Type BR Arc Fault Circuit Breakers and Loadcenters • Eaton Specification Sheet- BR816L125RP , . $ Switching Devices 1 . INFINITY HOME SOLUTIONS 1 1 . 1 Switching Devices infinity solar Safety Switches Safety Switdies 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 INFINITY SOLAR.COM Product Ovaview UM i Product Description g Used to open or close Standinds and Certifications s UV'Eie REVISIONS Prothict Selection Guide a cirdat • UL 50 Description Date Rev • Non-fusible safety * NEMA KS-1 Safety Switch switches provide a means to rnErrtuaNy connect or disconnect the load from 13 the source 11 `, :- • Fusible safety switches Signature with Seal . o. prowde a means to 1 )7";14;;: , ,' 0 , . rranuany open and dose i-pxf.:k: t;, .._ ' ; ,,:„,.> t n't- 1 ..., .. . a circuit and overcument ., ' ,,,,,, ,.. ,,,,,,,,,, :' , ,, 4410:', ':71114 J' e,' " $;',' / i , , , 0wo protection by means of 3414earzattr4. ' '"" r , , ; s Installed fuses 24,umttettet* ''-' a Also commonly referred to as a(hammed switch rarylpron Genoral-Thry rearraly Mere*MON iThesa nualielltsur Emhart irruyswirras or disconnect Project Name& VP Drop-awn fruriun rapletur nerrom Shp enwateenun userannots Marnrin Gie Cir • Available from 30 to 1200A Address Notexassreawilest natv r4,41C esysermerrrel mew hotepamt mkt W 0 ktur tlpe Z luster Nig Ern* CrUllgs earrdp LB Currge (.7) ruse= W if , q, ,y Amen rely; Mars 13 4ir it lAYs rirri 1111,1213 CL 0_mew* xt-tal re,12143 3f1,Br1 30-1796 46-12L ZiLL Startor r pre < — CNI to > r's fare I,2'and 3 2,.1 syl 4 4 2 mei 3 ,„, a) CC ct " M 2 err 3 0 0 C, J *MVO 2'Sr 3 2.3,4 ark 6 2.3.4 aryl E, 3 r0 4 = Ci- farm tgres LLI cf) remA4 1 c a, < LU LLI furls Its 'Sir Yes Yts < ,r 0 Z 1-0 1-= 0 fairs Nark Yes Yes 'AM let,s CO = — irs1,4 IP a. NAM Vrs Yes „,„,. 1;es yes Mr 1161* Yrs Yes Yrs res telAA t2 <>- ' Yes q' Yin,ept2ixt Its Yes --s 4rottatie Yes,up ezilfrA,A' ,(ts4, tm,up to Mr Ves 4.= 5 NEM 4 Flirted Met Parr Yr,kr-NM Sheet Name AC DISCONNECT NEW a swans Itti its 4131.1p to Mr Yes Yes. UL CERTIFICATION Man Mire IN,up us MCA Yes rts,up to WA Yes NEM Usanmetart up Sheet Size Fessrle . res„ ke rot — Yes Mr iterk — rs up rritt4 ...., Yes ANSI B INEMA 1,19 ..'- 1 1"X 17" n name -- YPI,up*MA,* .,. Sheet Number Naas Etaraj.RAMC pap Mt PM 333S Oran.fur VW rivitirs re RCP Sart Tr NFMA VW'12 endosom4136.Para um re ona racental la,,,,rem at rename reateinents tree a tarry prarearra MOW Is woven D S 04 V Mrs.1 ruse Mr pewter , Werra 2—Comenserril Distribadon 040111001303r—Apy9 1.01.4 seyncyasseaanyi 412-11-2 V2213-4 Voltam 2—Courrocta8lliste8korf1or Chrialreer11;—Apeilleit IIMICSAMICOM Switching Devices 0 Safety 1 . 1 infinity solar SiNitCheS INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE.1-800-818-0598 Cress-Riforo INFINITY SOLAR.COM Genernt-Duty General-Duty,;continued REVISIONS h n CerINg Nersr • CAI trimier Description Date Rev Rae Woo Semi Bsd*. gem SgsawO galas Una GoomalT3edic Simon Swat Rlrs lme. Pole:lero-Mrs,12O Vae.NEMA 1 MOM,llto-Pole.nne-W t.2401kie.r m*3R 1W O►11MCI Mal LFII IN 9211N 31 DG2211I101 10221@i 0f72181I 0271 W11 Meg Fuse.UrB-Pelf!T1111ee-Wit.240 WC.NEIMAI t 43r' Don= Tn2229 Gr2221 1 0227Nri0 21 04,221116E TI1r730 101164 WIN 100 06221=1 TSS3227i 59223104 0723N11 Signature with Seal FNs ,T4111e-PeNe.Tlnle-Wrb.240Vat,PN3MA1 2110 DUNES TG112E1 UMW 0274rA18 71 DC12N10E tE 2I ft721N 0721N 400 DC2P3il1M T+332:"1ll G177,3NR 0225MI EC DCZ S T6"r12 F.4227N 0222N 6ll0 DC22Wi. 11.12101 1;077£6#Ei 071GFAR Y00 MEMO T5 711 Gk273N 0223N R N1e.7lees-Polle.llrlee-Wler..24OVac,NEN A 3Ft 200 06211411I1 TE'3714 1022461 W24N 20 DC34111011 TGC210 59221t13 232191* 400 DFZER160 NF,'3725 CF22 1 11225NA E0 DORRIS Trv4322't GF327,15 172?2NEE Project Name& 1 Oil 1S ( 1G22G CF72G1 t072EN ro(1 DC EMS Tee GF333iR C3 NEE Address 66 W Fusible.Three-Pole,Three-Mfrs.240 Vac,NEMA 1 290 06321N111 GUM! %W74* 4324NHE Z Z 30' OG12118 1[43f1 I1 21N D321N 400 WWII TIM21,11 G132919 Man W 121 60' O6317N68 UAW 592721 1132211 6003 1363310011 Ta situ 59226 83261111 KC 1103231068 TG4321 Cf323 1 0322N Fusible,ltiree-Potq,I Wre,240 Mae,1 MA 3R W 201 01332411641 164324 G73244 1837411 30 DSMINMt 15E12161 592211111 UMW 411 116335F01 113325 r972174 037591 68 0G312101111 15122IIA GE322W 23221111 W 8 t3C 062311WOIC TERM Cf72l7tt D32G14 tIll 0023111110 TSR2221 a2f701 0323WE Z N 19 co Fusible,There-PIN.Fo1FYMre.240 Vac,MIA 1 229 062141 ll 114 01 GT324941 037491* > N Z 30 IrG3t7N68 HAP] Gf321111 032111 41T0 DC31 113'v7111, MAW13TIr9411 Z C CO MUMMUM054312 GF372T URNURNT3r0 MINIM T5n332O1 ,' GT321M L132GNfi CD Li IBC, O66220108 1G4371 Cf773N 07311 Roa-Fallie,71R►eer4 iWa-W0e.24*Wr NO RA 3R W 0, Q W W ar O 214110N 164374 G11246 17324N 33 D67218UO 1 111 6913211 1202219t Q 0 Z 456 DC3511011 154325 C �16 1a 062321 9 1C> 7f1 G9.1229 842777t10 Z CO m LO 1— O E193 maw 16412G r9726/4 18MN 00 0622311110 151103210 5111711 61-1700EN1V1 Now-ceslrle,Ttreo-Poie..lito-VrI e,240 Vac,NUM 1 200 D631lS= T 093321A Gr03201 111U32414ID Y M1 0C2281121 1 LN=I NIA NIA Nee-F0UOle.Aeee-Pole,T1r11e-Wle.,24O Mir.NEMA 2R Cl) D672NICE T[r17 2 WA 0182£Br4d15 30 DUO MOT 119 Glf12111 {1LT321€6 1110 DC MO TE463321 N/A [10 110NS GU DORM TGNM279 G611270 Et=ID?2FE 5 062241161 15947324 N/A 0(0524 100 DUMB 111133239 6P12231 04132313 40C DG315110A 169111326 NIA Rt.026. 2110 MINIM T9N3249 GN172tfl 041374F1e Sheet Name GTE 06 U*I 01742326 WA 0(197b 41l1 IX0119112 NIA WA WA AC DISCONNECT Nun-FrsWe,Tloee-Pele.lnree-Wit.24O WC,PO3MA 1 603 DC>M11I[ !4'1T WA WA UL CERTIFICATION 30 116321060 05142321 Cr19371 18(1.171 Mrs T11 DC312 1fdi3327 [{cam own *_ `• jrulals sinfirl ILt legated'. Sheet Size Ilr 04=113CB TGN3323 CdtiF32'3 nt.m Mays verity 18'e>ra tIetel pees '1111S15lte0 arce calms}rumbess ntri sweat In XLDC31N161 1Gi13224 1741F24 OU374 ae,hplei�ler ANSI B 403 D6329D6[ TOMS C.4072f. 00375 11" X 17" G11O D6311)6Z 1691032E I71^°24S OW 6 Sheet Number DS05 Mime CA00109003I-apii2016. erirrsrsoornmm 1F2-T1-5 3 infinity solar RSTC Enterprises, Inc. INFINITY HOME SOLUTIONS 14 Heimstead Road6405 E MILL PLAIN r G\lADECK VANCOU-80 WA 96661 Eau Il i!p �•yPHONE:1SOLARCOM'�if ad"T INFINITY SOLAR.COM `' 5-830-9 97 PLASHED PV ROOF-MOUNT 4 �P� IC1 [ ,A 1t t REVISIONS COMBINER/ENCLOSURES P #4! �.a* tJA Description Date Rev Outdoor Photovoltaic Enclosures 0799 Series Composition/Cedar Roof System �,�, ` �` Signature with Seal ETL listed and labeled Report#317141 1PRT-002 Revised May,2018 „ _ • UL5O Type 3R, 11 Ede Electrical equipment enclosures -- ,k `• �C22 2 No Nema Type 3R .''''' r• Project Name& ' Address W • Comas to UL 1741 Standard U Z w o 0799 Series Includes: w Saslael2 0799-4 07 -2 Wire sized 4 , 0799-5 Wire size 14-6 a a Z N to 0799-0 Wire size 1443 �i � > o 0) a Q' Models available in Grey,Black or Stainless Steel k" ci o Z o Q < W W Basic ectications d g ' z .,�. z H Material options: • Powder coated, 18 gauge galvanized steel >- (MOO hours salt spray) • Stainless steel Process-Seandess draw(stamped) Sheet Flashing- 15.25'x 17.25" JUNCTIOName BOX UL 3* Cavity-255 Cubic inches CERTIFICATION r Sheet Size Base Plate: ANSI B • Fastened to base using toggle fastening system =W . �. .. 11" X I T' • 5 roofdeck knock : • Knockout.sizes:(3),5",(1)_75°and(1) 1" -1 til Sheet Number * ",35rr, slotted di r n l i, 8� DS 06 * �dBlock Passthr�rl and cordikier kits are wadable for ear ,.. .,r_ JJ--,7 AC or DC applications. 0 Polyethylene kisuiated 2kV Rated PV 18-750 ARCM-2000 Valls--40°C Wet aldDry infinity solar INFINITY HOME SOLUTIONS 6405 E MILL PLAIN Description VANCOUVER WA 98661 00-818-0598 �%9 Sot i&brand ,has a� PHONE:1-8 ■T INFINITY SOLAR.COMLAR.COM cross-Ink d polyethylene irisulation. Bare REVISIONS Cr� Appl ications p. & p Appropriate for use k i solar power aiplicatio ins that require Desc hon Date Rev t<i ' ' I , 2,000 volt rating.. For 1199 in grounded interconnection and 133 Construction Conductors Stranded htve copper corichicto r per AS1M B-3,11--$_ Signature with Seal id 77. XLPE Insulation Available in 7'or 119 sha idedversions as well as tinned I115tdat10#0 ChernIi[ y Gross-inked polyethylene -- Sob'Lolarlir ' C0101= Buck,Green,White,lied. Print on one side vvith a " contrasting ink. An cxuudcd stripe and oilier colors am avail- Project Name& a able upon w Address siaIndustry Listings Standards z 119 l ..Listed as Phortmokaic" le par Standard SEijec t 4703 and 44 w Cable Identification ltit9►n - ° and Dry Rated in o � d t II w ft F PV WIRE OR�-2 OR 1 r -2 603V t0O'C3 F1O C MII)WET OR DRY 8$GRIP DIRECT BURIAL RoRS Sunlight d t?324841' VW-1 Flame Elating Optional LISTED a cN cNj �n Cable Data �'ce z N Q CL 4rital�Vikk- i+ia°aatnntrt3r:C7►. APPMEirllate 0 O _ Pat N 1A1M3 StrandNet Weight w co 0 r cc rnQLLJ W Lis 8182i 'V 18 7 75 .106 18 Z LO R. O 3162NPV 16 7 75 208 22 Z `— a 3142t it 14 7 76 .221 28 _ 31� 12 7 76 .� 38 Y 31021.PV 10 7 76 264 61 38321*V a 7 es .314 78 6 7 86 .361 112 3042NPV 4 7 66 _3911 166 Sheet Name 30321WV a 7 85 .427 203 WIRING 2 7 86 .469 240 SPECIFICATION 3012NP11 1 19 105 530 323 SOLO "ft 1/0 19 106 -672 390 Sheet Size 30292NPV 2A) 10 106 616 430 3030t214P1 3R1 10 106 .667 600 ANSI B 30402NPlP 410 10 106 _722 737 11"X 17" 30261112NPV 260 MOM 37 120 _798 8791 Sheet Number 30 300214PV 300 MOM 37 120 146 1046 366602NPV 36014CM 37 120 1108 DS 07 400 MOM 37 120 _946 1366 9X)6110361 37 120 1_029 1673 MCM 61 136 1.136 2011 1 lit:41)11 i 3060321+V 76EF IF►iGi41 61 186 12 2618 illehionnallbac torril*anallicatailYbliara alialecerating walelafaaanastlectan pea liateasoatalba Whig& MChausaaanal Mod baron the datada aclamb amnia atile goad pr Mk iwcaksibaitaellact bellmotaartimeatiamalWhetmaldnti cslPHONE: (1300) 343 2679 • FAX: (828) 389 3922 • WWW.AOCABLE.COM ..,,,,, ____ ,,, 1 ,,.„ 7, ,7.,,,,i,..., ..041,ci s013: :"I'""t r''° .3'.1E1'.1 ,• • • 0 11444. Grace Solar , i Grace Solar Grape Solar Pe'PAGP,PPrrPM P•i•ertrel infinity solar , INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 Components PHONE:1-800-818-0598 •, , „ . . , ROOF MOUNTING SYSTEM INFINITY SOLAR.COM REVISIONS Uri' G5-DR-Str P.a,risy i DescriPtion Date Rev Hcck 14-.4 GS ri4;,o , Pitched Roof Mounting System( Flashing L feet) 14.1 CIS-DR 2 ICC 4).Main mater ia I Signature with Seal Anodized Alt 005-T5 ..,.„. ,, . 040 8 enelitS ,.. „-____ ,„.„............,.... -,.. , -,, ',-- 1 It—t4 •Waterproof function , . 1 j ' . 1. ' • - ' t 1 I ' k' ', ,• •Easy Installation : L The parts can be pre-aosembiyed in the Project Name& _ -LI'"- T 1 actorsi to save your instal 1st on a nevi -V ` "1''' '' frnf '.,-- -- -V;4-- Address site.. 7i , , i. t f_ „1. w it 17. 'ft" i4-iLi, I. •„ . . __...-- -,,,. ri 0 Fiextbility and Compatibilirty Z Cart be instal lod with mass of tutor pa melt • ' - - ,, --wis ,.., , LLI ° es aisl or tri tie different coild Rion -- l I ," , ' ,..,....,--- 1011110Will IUMISIII co— , ...-- 0 Standard w , 4s0,9001.2008 U1.ASNZS 11 rd end CC ', , itthitr Irdesuatiorial a[rupture loud D standards. EL a_ a . : . .. r- up > cr) cr) fln Circund 4.,tij ii-74 84)11 d i ri is i is i is'..iti i Egli i'3,'Si U ii d..i d iisrpg IY ce c\I Z CrQ4111.%kV 4V 0 0 c, Li LLI u) CC . CC cn < Lii Lu . - ' ,,,,,"- 4 'k• < cr 0 4 .••,1:0-:i::, ,-- i .e".1 ‘—c° cT .. . ..: ,,,.,.,...,:„.. . .... 1 2 3 4 .. -. . . . ..,.. .. . 4-, ,- • - , , —a 5 Rail Rail splice kit Wave piece Clamp kit .,.., ..... - . . .. : .. - .. . . . . . ,.. "' •-' '' '' OS-DR-Irteis CS-OR-SP GS,SSC C-03 G LS-K- DJS , '' •••lll' • '' • • ' GS-FK-0 1:02 Sheet Name Lisistriesuri,CisSiflashing dos* ,astessciiie a:AY.t,4 so ow 4.3s110 MOUNTING- — , lif . . 2s 215-10firait DATA SHEET Shingle Roof(L.Feet) Sheet Size Alp 5 6 7 8 , ANSI B inter clamp kit 0-module End clamp kit Ground dip 11" X 17" 0S-A-01,1 GS-CC-F 55-13.C.SCI G S-1 K-L.D5 Sheet Number rtl , ''v .._, ....---- „,..-----i-i , , , -ii,iii•;,:i; Ei e strip ion GSL tee t 4.:-,..-.4,1sego”, Atin DS 08 , .. -3,404,,, -, .i, - • " ',,,, • 0 1 0 11 ....--- GS-A-ARCO Ground lug Bonding jumper FlashingD ii;Wu A hook P An-RI siii Pisa CS-G-GL CS-G.-Si-A CS-TR-0 Tin Roof(L Feet) B air ac*Solar pv s infinity solar Gv INFINITY HOME SOLUTIONS 6405 E MILL PLAIN MAIPAR VER WA 98661 ��1 iT PHONE:PHONE:1-800-818-0598 GSPITCHED ROOF RACKING SYSTEM INFINITY SOLAR.COM Rails And Splice Ic REVISIONS Description Date Rev DanoduJte can be put into GO Ftail from atrry position- via simple kistatlahicm. Benefits *Pre-assembled for easy installation , N D-r dule can be put into GO Rail from Pany position.Thisryes a µ f' insta ti earl and save you time on site. Signature nature with Seal •'Vario s Solution for the different conditions S � x€ GCS Railits accesses can be installed the most sow1. , i, , panes on the e�ial and residential Roof. ` �° ,`:; fety andReliability � I + ;,fi' ProectName& N r Address The ring systems designed by sli d engineers can stand up to the extreme r U At er with the.�► S 1170 and other international structure to/ 4 '� ' z standards.The main support components have also been tested ta+guarantee its 0 structure end load-carrying capacity. 7) GS-DR-Length(Classical GS-1OR-Length(Economy) description: t�S Radl 1# -Deesc ription: GS 1C3#Rail -Spec: 55x28mm -Spec: 48x 28mm d t i f• nation z g cp N ins ation Site Comrn al and Residential Root > a) N Z Tilt Angle Rushed with the roof,up to 00deg Material Mu mil um&Stainless steel O J_ Bulking Height up tcai5m Color Natural S t3iack. Gable can be mcJrted into z cn Q the Rai LL Max Wind Speed up to 8Dm/s Anti-corrosive Anodized �' rn Q W LU .1 ,,.. < U' ,, Snow Load 1.-WN/rn2 Warranittr 10 years warrant3+ �� P w" CL Standards ASINZS 1170&DIN 1055 Duration More than 20 years i Y >- GS-DR5-Length Mount with the cable GS-CRC-Length " //�� `�, `' Descrip n: GS 5#Rail -Description: Rail Cap �tl,l rn E� Spec: x4grnm -Spec: 24x1Ornm Sheet Name � �ri RACKING- �.. �' DATA SHEET t a" Rail Connectiotl Grounding Washer,'Washer ANSI B x Sheet Size f 007 mil i1 e om;,. . 11" X17" - Sheet Number DS 09 GS-DR-SP Rail Connection GS-DR-SP-GW Descxiption: Rail Sp�oe -Description: Rail Spl with Spec 15t9rrrm grounding washer washer -Spec: 150mm aA Xiamen Gran.Saarr Ga.,Lftl. xuman Grata Saar T'anhnm/opyCa,,Ltd. "�"ix �nrwii�.c�ns irwaLikaaaaaYr-men, • . , 0 infinity solar lk" rill 1...1 4".... INFINITY HOME SOLUTIONS , fofs arsol wrasol ----- • -, , , ,'1., i ' J L'l''; ;' ,,,' '''' ' ' r.' ).„..,4,,, ' • ,,g• 'z ' IMIR ,, '( I, ' 4 ' ' ' ' ,tir 6405 E MILL PLAIN VA NCOUVER WA 98661 .0...-...h.. Th0,6.1.,*.N.0...*04***0 .,.'';'',"n'=N'',WANWtiFti, f5d1",itiOqfri"-i',:,,,,,,,VD$40',',,,M;14titig.:&*•tir;VePANIPO'MIRW':':t-VOti***,,VP,gni,',":,!! AriOttiV:,',','MZ"',,f;NM:0,V4itigtiOtip, ';',;,:;,6:Mita,e',,E-2',0'T„,,,,O,,r1tigegitittinete .!;,, ,,,',';,44.P.,,fp?1,''',.V;,!'':rani$A.V!''..--;02,N3VE''',:,',18fttiRK5,1Y'''',Fi,ntititift%,,,:;,,,,;,':;'. ,,,,,'''!,,',3i44440tiNitiftiVtiiN,',-,M.,,;',,q;',PRtitif4atigrai;,,;:'', PHONE:1-800-818-0598 INFINITY SOLAR.COM REVISIONS Description Date Rev COMPONENTS c,"!,i,, , --..". ... .. .,,.. . .. ,. „. „_..„.. . „.,10,,,,,,,,,.. ...• alimi ...„.,,,,....i„..,.,4,00.:,;,,,,,,.!,,..„A:,,,,a,J„i„,:,::::,....:!,,;,ii,. .,,,...,..zati,,,,....,:,:i,.,.,,:-.._::...,i,.0,,,,v,„,4012.4, .:,.,:: •,,,.., ,,,w000,0a:,,,., :„i..,„:„:.;,. .,. . ..,06..„.• „.,,,. ,,•:„.:,,..i:,,,.,...,...":,..... ,.. ,,..t.,..,..,....,.,.,,,„,„,„.... „,0.,„„,,4...„,,,,,,,...,„,„,„„,14,,,,„„,,,„:„,„,,,:,,,N,,:,,,,,,,f,:,t,,,,WAtiMii*,•",..,,,,,',;: , • ..,•• ., - ', ,„. Signature with Seal , ..., -"-.4:-il.',;.,„-4.,..,:-:::'. _... '•1 ••""r- . ,.... ... .:. . 00:•• r:0'''H,.. ••• - •.. ...„. '•""::::::'5 ::. — •••'••:-..-.. ,........ .......„.„...„:„.„.... .................„...... ....,„......., Features ,,.,,.,..,...... ,.... . Material:SUS3U4 . ... * ra-T:iiiir4tara'''' tia frexura arc ''' ' ' ,-V 1 '` % ' ' Pik inkt.zton 4.r.d d.ratt. . Special rib both surface to pierce the aluminum anodization trown%til;Ponn Ovutirjr,rofl ,,g;70,10,44' r ''',"-- ...- :,..-..—"- ''...' .-:-,--',-- , - Cooperated with Inter Clamp to install under the Rail .„„.,..„aitia... 40:1M-',..-Vogik, 14:-',.. .-,,,....',:r.-.',.,;,--'..• 16110001111116. -z '''''4C;;i1 ligllit*141dt!:::L2.;'i:iailiegll:PO100k:L':2:1a:d:iiiigilgi2 '?''' Project Name& Address W 0:- r-. •'•', -.‘----JrA't, -:.,.,,..,..! ,°:•'-':' .:-4..,,e-0,,,' 0 1,,...-:4-:.--"Cr._,,,,' iii 1110.1111r111/16 GS-G-GC Groundiry Clip '':..,15#'-''". '"''':;,-*-'1:, A. VOA.110111,wall'1104111. = LLI e•,,,::.. ..:;,...4.:, * 16.7.: -.---"-- .0:::;,;,,,,404,04-.. ,• - , 0 •-• ,•••,,.,0.44,,.. 05.,.k,i,,,,, ' pz, Linctirroly Mf.,571-Tilamd 4'145 •If?..,,,,' ,,., Brulioni Coppali Vi**. (/) . H.t...5, •'' ' ." . Ct .:,...,:. ' 'e,:,„,i; ',1•;',F40•• , r..1 in — ,...4 . > 6.; CI) tic F eat Uftli5 < ee n, CNI Z - Connect system to equipment ground conductor 0 0 — .:7:. Li SOLAR ARRAY. • High Pre-assembly z 0- N- W cr) ce ... Et 0., < 1.1J L.1_1 < •:1- ° ,....,M GROUNDING SYSTEM „ „..,,,....... ,. .. .„.„........ .... .... . .. .„. .„...„..... „,.:::i.,,,..„ ,,VUINS41,01;', ',:. Vgge,,,,,,,,,,,,,,,'"',,,',,,',,,,,,,,,V,,,'•,,,,,s'i,asn'4,0,,,!;-,,,,....,,.,„„,,,„„,,,po.!§,,,,,,,...:.,::.::,,,,,,.„.„,,,,,,a,m,,,,,,,,,,,,g,,,,,,,,m,,,,,, G.S-G-GL Grounding Lug .....„ ....... . „„...................,„ CO = •g•"..'7,0"..-• ..: ',': .. .11k,V'An% ,,g :„„g.„ • ., g.,„ g.„.,, •tiffaterial:A16005-T5 lay-in lug&StainleSs Steel Clip 4,A2-7CI bolt 1,).Introduce 2 .. . GS Grounding Product can be used to bond solar modules to the aluminum rails and the aluminum rails to ground, so that the entire solar system is grounded and safe; Grounding products —J inctilde the stainless steel grounding clip and aluminum grounding lug, which are all designed to comply GSJGZGL Copper Ground 5ing Lag ' ,:. ..„,' with the requirement of A55033,UL467 for bonding or grounding systems. -Material: Copper lay-in lug&Stainless Steel Clip&A2-70 bolt Sheet Name Planning Layout RACKING- GROUNDING Sheet Size Cwf*r W to 0 Grmalciimq Clip . Features ANSI B siam sisi 011110011 ea NO Material: Braided Copper Wire&Stainless Steel Chp&A2-70 bolt 11" X 17" High Pie assembly- X GrOttinding 4....14) . . -,,,.,.., , , • Electrically connect spliced Rails Sheet Number :: ......„, : r -”. Excellent electric conductivity y . DS 10 I:3 Boodirg Jurripts gi041*f Noii4 ilEINNONNEVADOW)0605.'AlpistoulagnIt ,,,, ,,4,,, '' ', MCNOSMaigMetRs,;ft,'',4,,,,Zk4ZW,W,,,W!,:%,,g, ,iN,OM*,Zf':';',5,!,,,Y.V!W,,, ,'',:,'N, GS-G-13.1 Bonding Aillifer NW ova 011111410 MB WIN , r . 16 15 0 infinity solar CERTIFICATEOF COMPLIANCE INFINITY HOME SOLUTIONS 6405E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 Certificate Number 20181008- E499263 INFINITY SOLAR.COM Report Reference E499263-20180927 REVISIONS Issue Date 2018-OCTOBER-08 Description Date Rev Issued to: XIAMEN GRACE SOLAR TECHNOLOGY CO LTD Bldg. E No- 195 GaoQi BeiSan Road Signature with Seal (GaoQi Industrial Park) Xiamen Fujian 361 006 CHINA. This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, Project Name& Address representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS Mounting Systems for Use with Photovoltaic Modules and Panels, Model GS-PR-1 0R. Have been investigated by UL in accordance with the Z g CV tf) Standard(s)indicated on this Certificate. > N z 0 00ci 0 � Standard(s)for Safety: UL2703"Standard for Mounting Systems, Mounting w cr) Devices, Clamping/Retention Devices,and Ground Lugs for Q v 0 Z "' O use with Flat-Plate Photovoltaic Modules and Panels", zco a_ Additional Information: See the UL OMB, Certifications Directory at www_ul_comtdatabase for additional information only those products bearing the UL Certification MEarl'should be considered as being covered by UL's Certification and Follow Up Service. Sheet Name Look for the UL Certification Mario on the product_ RACKING- CERTIFICATION Sheet Size ANSI B 11" X 17" Sheet Number DS 11 dediPPAWAS LLC 41111D1 Any rrrn Nod ,..sr.+nurbut Wart. wp.wruyes,f.rr.e tit ecct Ies env wrsIe.trwst+a. 4..e�.■ sarnt.-U.cotes*ram r-,. - .r Page 1®f 1 Created by UL Document Assembler 2018-10-24 22:15:06-05:00