Loading...
Plans A in B • C • D • E ■ F is G ■ H 1 GENERAL NOTES NEW PV SYSTEM : -13.860 kWpRECEIVE®VALIDITY OF PERMIT SMART 1.1.2 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC THE ISSUANCE OF A PERMIT FEB 1 3 2023 S L A R CODE (NEC) ARTICLE 690, ALL MANUFACTURERS'S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY STEFFEN RESIDENCE BASED ON CONSTRUCTION ENERGY ■ HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. DOCUMENTS AND OTHER CITY OF TIGARD ■ 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM DATA SHALL NOT PREVENT BUILDING DIVISION INSPECTED PRIOR TO PARALLEL OPERATION THE CODE OFFICIAL FROM 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED 12647 SW 133RD AVE REQUIRING THE CORRECT'ON CONTRACTOR WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B) OF ERRORS. ORSC 105.4 1.1.5 ALL PV SYSTEM COMPONENTS;MODULES,UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN TIGARD OR 97223 SMART SOLAR ENERGY CO 2 PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: SHEET�^t� LIST ST TABLE PV MODULES: UL1703, IEC61730,AND IEC61215,AND NFPA 70 CLASS C FIRE I INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519 ASSESSOR'S #: 2S 104AC03900 COMBINER BOX(ES):UL 1703 OR UL 1741 ACCESSORY SHEET NUMBER SHEET TITLE PHONE: 971-645-2487 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP T 001 COVER PAGE ADDRESS:10940 SW BARNES RD#250 COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED PORTLAND,OR 97225 ACCORDING TO NEC 690.7. 'i•; G-001 NOTES ■ 1.1.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND SOURCE i. r • LIC.NO.: 234657 CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL ,,;. A-101 SITE PLAN HIC.NO.: BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE ELE.NO.: INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING[NEC A 102 ELECTRICAL PLAN UNAUTHORIZED USE OF THIS 110.3]. DRAWING SET WITHOUT WRITTEN 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF A 103 SOLAR ATTACHMENT PLAN PERMISSION FROM CONTRACTOR IS IN EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE VIOLATION OF U.S.COPYRIGHT LAWS �► E-601 LINE DIAGRAM AND WILL BE SUBJECT TO CIVIL 3 WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. DAMAGES AND PROSECUTIONS. E-602 DESIGN TABLES 1.2.1 SCOPE OF WORK: E-603 PLACARDS NEW PV SYSTEM: 13.860 kWp 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT.PRIME CONTRACTOR WILL BE S 501 ASSEMBLY DETAILS STEFFEN RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE R-001 RESOURCE DOCUMENT RESIDENCE ■ PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. LI' I LIT` 1.3.1 WORK INCLUDES: The City,of Tigard aP :t R 002 RESOURCE DOCUMENT 1.3.2 PV ROOF ATTACHMENTS-SUNMODOSOLOFLASH f'a pto ' ° " . , __+§ R-003 RESOURCE DOCUMENT 12647 SW 133RD AVE 1.3.3 PV RACKING SYSTEM INSTALLATION-SUNMODOSMR100 r`spr, s? le gin. el B 5 c[ TIGARD, OR 97223 R-004 RESOURCE DOCUMENT 1.3.4 PV MODULE AND INVERTER INSTALLATION-MISSION SOLAR MSE385SX5R h�;,;,i m v` 1."cn_.. Pe rel i. I APS DS3-S AERIAL PHOTO R-005 RESOURCE DOCUMENT APN: 2S104AC03900 4 1.3.5 PV EQUIPMENT GROUNDING 01 1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX SCALE:NOT TO SCALE 1.3.7 PVLOADCENTERS(IFINCLUDED) Approved plans ENGINEER OF RECORD 1.3.9 PV ME METERING/MONITORING(IF INCLUD RING/ ONITORING(IFINCLUDED) shall be on job site. PROJECT INFORMATION ONNECTS 1.3.10 PV GROUNDING ELECTRODE&BONDING TO(E)GEC OWNER 1.3.11 PV FINAL COMMISSIONING NAME: MICHAEL STEFFEN • 1.3.12(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV _ s,'j�, PROJECT MANAGER 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE _— _—�— 46 NAME: JENN SHOWERS \ CITY OF TIGARD 9GF PHONE: 971645-2487 CONTRACTOR REVIEWED FOR ' DE COMPLIANCE `\ NAME: SMART SOLAR ENERGY CO PHONE: 971-645-2487 5 OFFICE COPY Approved: [ AUTHORITIES HAVING JURISDICTION BUILDING: WASHINGTON COUNTY PAPER SIZE:11"x 17"(ANSI B) OTC: [ � .' ZONING: WASHINGTON COUNTY Pcrrnit#: r 6l20 Z`?j b30 3 UTILITY; PGE `s"A2 DESIGN SPECIFICATIONS COVER PAGE • Address: it �� �� �44 OCCUPANCY: II SCOPE OF WORK Suite #' Ts> CONSTRUCTION: SINGLE-FAMILY DATE: 01.15.2023 /� ZONING: RESIDENTIAL GRID-TIED ■ SYSTEM SIZE: pTC:36 X 356W=12.816KW A'� Date: 3 3 GROUND SNOW LOAD: 36 PSF DESIGN BY: S.G. (36)MISSION SOLAR MSE385SX5R WIND EXPOSURE: B CHECKED BY: M.M. (18)APS DS3-S WIND SPEED: 110 MPH N BUILD APPLICABLE LE CODES OSISC 2010,OSSC 2019 TANDARDS REVISIONS ATTACHMENT TYPE: SUNMODO SOLOFLASH 02 RESIDENTIAL: ORSC 2021 w E FIRE: OESC2019 : SCALE T-OOI •OO MSP UPGRADE: NO SCALE NOT TO ELECTRICAL: OSSC 2021 s A • B • C • D • E • F • G IN H (SHEET 1) A • B • C • D • E ■ F • G • H 2.1.1 SITE NOTES: 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN t- 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, C 1 IV 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES SMART INTERACTIVE SYSTEM WITH STORAGE BATTERIES. PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. F 1 2023 S L A R 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING 2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL ROOF VENTS. OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. CI F GARD ENERGY ■ 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL 2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR BU ING D !SI01 EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] 2.1.6 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF 250.106. IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A GROUNDING ELECTRODE CONTRACTOR COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 AND AHJ. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(6)(1)AND(2)TO REDUCE FIRE SMART SOLAR ENERGY CO 2 2.2.1 EQUIPMENT LOCATIONS: HAZARDS 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLE 310.15(B)(2)(A). 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE PHONE: 971-645-2487 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED "LINE ADDRESS:10940 SW BARNES RD#250 690.34. SIDE"(TYPICALLY THE UPPER TERMINALS). PORTLAND,OR 97225 2.2.5 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A i LIC.NO.: 234657 iii SIGHT OF THE AC SERVICING DISCONNECT. VISIBLE-BREAK SWITCH HIC.NO.: 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN ELE,NO.: NEC APPLICABLE CODES. FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH UNAUTHORIZED USE OF THIS 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN 690.12(A)THROUGH(D). DRAWING SET WITHOUT WRITTEN APPROPRIATE. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9,AND 240. PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS 2.6,6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN AND WILL BE SUBJECT TO CIVIL 3 2.3.1 STRUCTURAL NOTES: ACCORDANCE WITH NEC 110.3(B). DAMAGES AND PROSECUTIONS. 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT 2.6.7 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEW PV SYSTEM: 13.860 kWp INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, NEC 690.11 AND UL1699B. AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE STEEPEN ARRAY/SUBARRAY,ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. 2.7.1 INTERCONNECTION NOTES: 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12(B)] RESIDENCE ROOF-PENETRATING TYPE,IT SHALL BE FLASHED&SEALED PER LOCAL REQUIREMENTS. 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/APPROVED RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. PERCENT OF THE AMPACITY OF THE BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE 12647 SW 133RD AVE 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(B)(2)(3)]. SPECIFIED BY THE RACKING MANUFACTURER. 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL RATING OF ALL TIGARD, OR 97223 2.3.6 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE APN: 2S104AC03900 4 THE ROOF FRAMING MEMBERS. COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12(B)(2)(3)(C). 2.7.5 FEEDER TAP INTERCONNECTION(LOAD SIDE)ACCORDING TO NEC 705.12(B)(2)(1) 2.4.1 WIRING&CONDUIT NOTES: 2.7.6 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH SERVICE ENTRANCE ENGINEER OF RECORD 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND CONDUCTORS IN ACCORDANCE WITH NEC 230.42 WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM TO LIMIT UP-SIZING. ADDITIONAL FASTENING[NEC 705.12(B)(5)]. 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. ■ 2.4.4 VOLTAGE DROP LIMITED TO 1.5%. s 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE 5 PHASE C OR L3-BLUE,YELLOW,ORANGE**,OR OTHER CONVENTION PAPER SIZE.11"x 17"(ANSI B) NEUTRAL-WHITE OR GRAY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED NOTES ORANGE[NEC 110.15]. 2.5.1 GROUNDING NOTES: DATE: 01.15.2023 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DESIGN BY: S.G. ■ DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. um 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE CHECKED BY: M.M. 250.122. 2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED REVISIONS 6 GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND G�O� *00 MICROINVERTER MANUFACTURERS'INSTRUCTIONS. A • B • C • D • E • F • G • H (SHEET 2) A ■ B ■ C ■ D ■ E ■ F ■ G ■ H GENERAL NOTES -1 1. FIELD VERIFY ALL MEASUREMENTS SMART 2. ITEMS BELOW MAY NOT BE ON THIS PAGE S L A R ENERGY ■ ------- PROPERTY LINE ■ CONTRACTOR 2 SMART SOLAR ENERGY CO UTILITY METER AUTOMATIC TRANSFER SWITCH PHONE: 971-645-2487 AC LOAD CENTER ADDRESS:10940 SW BARNES RD#250 AC DISCONNECT FUSED PORTLAND,OR 97225 ■ • LIC.NO.: 234657 s HIC.NO.: L �,�3�0 EN E UNAUTHORIZED USE OF THIS - 94., DRAWING SET WITHOUT WRITTEN -- - \\ t „ PERMISSIONFROM CONTRACTOR IS IN VIOLATIONONU.S.OF U COPYRIGHT LAWS -- AND WILL BE SUBJECT TO C 3 — 1 -10 \ DAMAGES AND PRO ECUT OINIS. _ —� — CD ,,,--'- * 30'-10" \ NEW PV SYSTEM: 13.860 kWp STEEPEN lk ■ AREA OF WORK RESIDENCE " ' N ,\ 700 * 12647 SW 133RD AVE N , o O ENTRANCE TIGARD, OR 97223 ° ° � APN: 2S104AC03900 N \ N `\\ • jib, ` N , \� ENGINEER OF RECORD .77. NS, 1 , \\ . N • / N `, 14'-9" \ \11111111*- i N N 5 PAPER SIZE:11"x 17"(ANSI B) N34'-1" 7 v SITE PLAN sAfrey 4ez> X DATE: 01.15.2023 s l DESIGN BY: S.G. ■ I CHECKED BY: M.M. SITE PLAN N 6 0 REVISIONS W E 1116"=1'0" 0 16j A-101 .00 s A ■ B ■ C r D • E • F • G H (SHEET 3) A ■ B • C • D • E • F • G • H PLAN VIEW TOTAL ROOF AREA:1702.26 SQ.FT. GENERAL NOTES c M -1 PLAN VIEW TOTAL PV ARRAY AREA:771.65 SQ.FT. 1. FIELD VERIFY ALL MEASUREMENTS S " A R T PERCENTAGE OF ROOF SPACE USED BY SOLAR PV ARRAYS:45.33% ARRAY 1-1.540 kW 2. ITEMS BELOW MAY NOT BE ON THIS PAGE S L A R [x4](N)MODULES ENERGY ■ TILT:27 DEGREES II ROOF PITCH:6:12 AZIMUTH:336 DEGREES 12" FIRE ACCESS PATH EXTERIOR PV EQUIPMENT (E)(1)UTILITY METER CONTRACTOR 12" FIRE ACCESS PATH (E)(1)AUTOMATIC TRANSFER SWITCH (N)(1)AC LOAD CENTER 2 SMART SOLAR ENERGY CO (N)(1)AC DISCONNECT FUSED 36" FIRE ACCESS PATH INTERIOR PV EQUIPMENT A MODULE STRINGING (E)(1)MAIN ELECTRICAL PANEL 12" FIRE ACCESS PATH , OB MODULE STRINGING PHONE: 971645 2467 ADDRESS: 10940 SW BARNES RD#250 12" FIRE ACCESS PATH OC MODULE STRINGING PORTL AND,OR 97225 I J . LIC.NO.: 234657 .// (N)(1)JUNCTION BOX O MODULE STRINGING HIC.NO.: /' ;`// UUNAUTHORIZED AU NO.: /�/7/7/7/ f//`/ ' l DRAWING SET WITHOUT WRITTEN A B /i B / 12" FIRE ACCESS PATH ./;,';r FIRE CLEARANCE PERMISSION FROM CONTRACTOR IS IN 1 VIOLATION OF U.S.COPYRIGHT LAWS 3 AND WILL BE SUBJECT TO CIVIL A B / o ; D D D D 12" FIRE ACCESS PATH DAMAGES AND PROSECUTIONS. ,/� p / r NEW PV SYSTEM: 13.860 kWp q ��.///// ,�/,�//, r / STEFFEN ilk D D A B o RESIDENCE Mr D ARRAY 5-6.160 kW / ARRAY 2-1.540 kW 12647 SW 133RD AVE [x16](N)MODULESille A B s TILT:27 DEGREES [x4](N)MODULES ROOF PITCH:6:12 / g ` D TILT:27 DEGREES TIGARD, OR 97223 AZIMUTH:246 DEGREES A B // O Ia ROOF PITCH:6:12 APN: 2S104AC03900 fj� ZIMUTH:156 DEGREES 4 /ff B g 12" FIRE ACCESS PATH A / , ENGINEER OF RECORD 1 ,/ `, 12" FIRE ACCESS PATH A WI 4 A . ./ O O ARRAY 3-1.540 kW • [x4](N)MODULES ��' TILT:27 DEGREES A /,' 411 O O ROOF PITCH:6:12 AZIMUTH:66 DEGREES 5 PAPER SIZE:11"x 17"(ANSI B) 12" FIRE ACCESS PATH ARRAY4-3.080kW [x8](N)MODULES ELECTRICAL PLAN TILT:27 DEGREES - 12" FIRE ACCESS PATH ROOF PITCH:6:12 AZIMUTH:246 DEGREES 41.1" DATE: 01.15.2023 I I DESIGN BY: S.G. IMODULE: CHECKED BY: M.M. 6 ELECTRICAL PLAN w " 75.1" MISSION SOLAR MS 38 SX5R REVISIONS 01 1/8"=1'-0" 0 8' e 385 WATTS s A-102.00 A NI B • C • D -• E • F wG • H s (SHEET 4) A ■ B ■ C ■ D ■ E ■ F in G ■ H -1 SMART FLUSH MOUNT SOLAR MODULES S L A• ATTACHED TO ROOF SURFACE(SEE ENERGY SHEET S-501 FOR MOUNTING DETAILS) ■ ■ CONTRACTOR ROOF ATT.TYP. @48" MAX 2 SMART SOLAR ENERGY CO J---- p....i i i•go.I i - ' GENERAL NOTES ...�...' - - I - I PHONE: 971-645.2487 _ _ �I j �13,--1�' 1 FIELD VERIFY ALL MEASUREMENTS .-- I I ' "� 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ADDRESS:10940 SW BARNES RD#250 �� - - �- I I m Wi PORTLAND,OR 97225 - _ - - - a - - ' Ailli I I I I I �/' 3. UTILITY HAS 24HR UNRESTRICTED ACCESS _ _ _ _ I I I I I TO THE PHOTOVOLTAIC SYSTEM METER AND • LIC.NO.: 234657 ■ � _ _ ® - _ W, P' .117 DISCONNECT AT SERVICE ENTRANCE. HIC.NO.: --- ROOF TRUSS UNAUTHORIZED USE OF THIS f II I , DRAWING SET WITHOUT WRITTEN ;- - PERMISSION FROM CONTRACTOR IS IN �= _ /__ . / / 3'ROOF OUTLINE OFFSET VIOLATION OF US.COPYRIGHT LAWS / iio ► //// DAND WILL BE AMAGES AND SUBJECT O CIVIL ' I` 111 b I b --L-L-2-\ NEW PV SYSTEM: 13.860 kWp -, � STEFFEN ■ 2X4 TRUSS @24" O.C. — - - -_ - '-- =- '%` ' ,_ _ - RESIDENCE ROOF ATT. TYP.@24" MAX. __ - 12647 SW 133RD AVE (WITHIN 36" OF ROOF LINE) __ ... , -� efr TIGARD, OR 97223 llf -'e i - - - - APN: 2S104AC03900 4 ROOF MATERIAL IS ASPHALT SHINGLE -o- _ / '' ‘� - - f - - -- � _ - ENGINEER OF RECORD -- - -o- - -- - -e-0-- - o- 2X4 TRUSS @24" O.C. A ' .. _ _ I II 5 PAPER SIZE:11"x 17"(ANSI B) SOLAR ATTACHMENT PLAN 41.1" DATE: 01.15.2023 ■ DESIGN BY: S.G. ■ MODULE: CHECKED BY: M.M. MISSION SOLAR 6 SOLAR ATTACHMENT PLAN w " 75.1" MSE ION SOL REVISIONS 01 1/8"=V-0" 0 81 S F 385 WATTS A-103.00 A • B • C • D - E • F • G ■ H (SHEET 5) A • B • C • D • E ■ F • G • H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT-CARRYING TEMP.CORR. CONDUIT FILL CONT. MAX.CURRENT BASE AMP. DERATED TERM.TEMP.RATING AMP.@ TERMINAL SMART -1 ID TYPICAL CONDUCTOR CONDUIT CONDUCTORS IN CONDUIT OCPD EGC FACTOR FACTOR CURRENT (125%) AMP. 1 1 12 AWG THWN,COPPER 0.75"DIA PVC-40 8 20A 12 AWG THWN,COPPER 0.96(33°C) 0.7 13.5A 16.88A 30A 20.16A 75°C 25A S L A R 2 1 4 AWG THWN,COPPER 1"DIA PVC-40 2 70A 4 AWG THWN,COPPER 0.96(33°C) 1 48.6A 60.75A 95A 91.2A 75°C 85A 3 1 4 AWG THWN,COPPER 1"DIA PVC-40 2 N/A 4 AWG THWN,COPPER 0.96(33°C) 1 48.6A 60.75A 95A 91.2A 75°C 85A ENERGY ■ ■ CONTRACTOR SMART SOLAR ENERGY CO 2 1. SYSTEM DESIGN CALCULATIONS REPORT ID LENGTH VOLTAGE DROP 1.1. PV SOURCE CIRCUIT VOLTAGE RANGE TEST 1 45 FT 0.86% PHONE: 971-645-2487 THIS TEST CONFIRMS THAT THE VOLTAGE OF THE PV SOURCE CIRCUIT WILL ALWAYS REMAIN 2 1 FT 0.01% ADDRESS:10940 SW BARNES RD#250 WITHIN THE DC INPUT VOLTAGE WINDOW OF THE SYSTEM'S INVERTER,MICROINVERTERS,OR POWER OPTIMIZERS. 3 1 FT 0.01% PORTLAND,OR 97225 1.1.1. (1)MISSION SOLAR MSE385SX5R(385W)IN SERIES ■ LIC.NO.: 234657 is SECTION PROPERTIES VALIDATION TESTS HIC.NO.: ELE.NO.: DESCRIPTION (1)MISSION SOLAR MSE385SX5R E US O Z THORIED F THIS (385W)IN SERIES THE MINIMUM VMP MUST EXCEED UNAUNAU HO ZEDUS WITHOUT WRITTEN THE MINIMUM INPUT VOLTAGE OF PASS PERMISSION FROM CONTRACTOR IS IN CONNECTED DEVICE APS DS3-S THE CONNECTED DEVICE VIOLATION OF U.S.COPYRIGHT LAWS CONNECTED DEVICE TYPE MICROINVERTER AND WILL BE SUBJECT TO CIVIL 3 DESIGN LOW TEMP. -10°C 31.86V>16V=TRUE DAMAGES AND PROSECUTIONS. DESIGN HIGH TEMP. 33°C THE MAXIMUM VOC MUST NOT NEW PV SYSTEM: 13.860 kWp MODULE MISSION SOLAR MSE385SX5R THE MAX INPUT VOLTAGE PASS 125A AC LOAD CENTER PV SYSTEM EQUIPPED WITH RAPID 2 EXCEED (N)(18)APS DS3-S MODULE VMP 36.93V OF THE CONNECTED DEVICE 120/240V,10,3W SHUTDOWN DISCONNECT PER NEC 690.12 STE F F E N SYSTEM COMPLIANT WITH NEC 690.13 MODULE VOC 45.03V 49.16V<60V=TRUE (N)(36)MISSION SOLAR MICROINVERTER MIN.INPUT 16V MSE385SX5R VOLTAGE 385 WATTS RESIDENCE • MICROINVERTER MAX.INPUT (N)JUNCTION BOX VOLTAGE 60V _ TO UTILITY MOUNTING METHOD FLUSH ROOF MOUNT O - - ---t 0 CID GRID(UG) 12647 SW 133RD AVE TEMP.COEFFICIENT VOC -0.118 V/°C NV Map-up VOLTAGE LOSS DUE TO t0 - 1 TIGARD, OR 97223 DEGRADATION DERATE 0'0 IN BRANCH "I N L2 I APN: 2S104AC03900 VOLTAGE LOSS DUE TO _ _ _ _--i 2® (E) INVERTER MIN.VOLTAGE 10 •:`w*. 110 UTILITY INCREASE DUE TO HIGH 0.0 IN BRANCH MRED ADE (E)AUTOMATIC TRANSFER METER ENGINEER OF RECORD TEMPERATURES I I SWITCH GROUND _ ® (N)AC DISCONNECT,100A ROD CALCULATIONS O igu,Am ip:in 1 20A WITH FUSES,70A I 1� --.--II. A.STRING VOC AT LOW 8 `�`—n—' I N L— - (E)GROUNDING 49.16V IN BRANCH "�+ N I (E)MAIN ELECTRODE ■ ■ TEMPERATURE I I I 200A THE MODULE VOC(45.03V)WILL INCREASE TO 49.16V AT THE -1 I ' El L2 DESIGN LOW TEMPERATURE(-10°C). O WPM•,.. _ I 20A Q C� ®O I J L ® To E 10°C-25°C)X-0.118V/°C+45.03V=49.16V I ® ( ) \ /FED 49.16V X 1=49.16V IN BRANCH :Fi r �;�4 I `2 L1 _ eoa2 LOADS -+i- I (E)MAIN ELECTRICAL PANEL \ I PAPER SIZE: x 17"(ANSI B) 5 B.STRING VMP AT HIGH 31.86V I I 240/120 V 10,3W (N)ELECTRIC TEMPERATURE I MAIN BUSS!200A VEHICLE CHARGING ESTIMATED CELL TEMPERATURE EQUALS THE DESIGN HIGH EQUIPMENT LEFT I(E)GENERATOR --J NEMA 14-50 OUTLET LINE DIAGRAM TEMPERATURE(33°C)PLUS 35°C(THE ESTIMATED DIFFERENCE OF LINE IS(N)NEW I UNLESS OTHERWISE NOTED. I EQUIPMENT RIGHT BETWEEN AMBIENT TEMPERATURES AND THE CELL TEMPERATURE I OF LINE IS(E)EXISTING FOR A FLUSH ROOF MOUNT). 1 UNLESS OTHERWISE NOTED. DATE: 01.15.2023 33°C+35°C=68°C DESIGN BY: S.G. ■ THE MODULE VMP(36.93V)WILL DROP TO 31.86V AT THE DESIGN II HIGH TEMPERATURE(33°C). CHECKED BY: M.M. (68°C-25°C)X-0.118V/°C+36.93V=31.86V REVISIONS 6 E-601 .00 A • B • C • D • E ■ F • G • H (SHEET 6) A I. B . C . D . E . F . G . H SMART S LAR ENERGY ■ • CONTRACTOR 2 SMART SOLAR ENERGY CO SYSTEM SUMMARY MODULES BRANCH#1 BRANCH#2 BRANCH#3 BRANCH#4 REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING INVERTERS PER BRANCH 5 5 4 4 PM1-36 36 MISSION SOLAR MSE385SX5R 385W 356W 10.97A 10.42A 45.03V 36.93V -0.118V/°C(-0.26%/°C) 20A PHONE: 971-645-2487 MAX AC CURRENT 13.5A 13.5A 10.8A 10.8A ADDRESS: 10940 SW BARNES RD#250 MAX AC OUTPUT POWER 3,200W 3,200W 2,560W 2,560W PORTLAND,OR 97225 ARRAY STC POWER 13,860W INVERTERS ARRAY PTC POWER 12,816W AC OCPD RATED MAX OUTPUT MAX INPUT MAX INPUT CEC WEIGHTED ■ LIC.NO.: 234657 REF. QTY. MAKE AND MODEL VOLTAGE GROUND RATING POWER CURRENT CURRENT VOLTAGE EFFICIENCY HIC.NO.: MAX AC CURRENT 48.600A MAX AC POWER 11,520W 11-18 18 APS DS3-S 240V FLOATING 30A 640W 2.7A 2X16AA 60V 96.5% ELE.NO.: UNAUTHORIZED USE OF THIS DERATED(CEC)AC POWER 11,520W DRAWING SET WITHOUT WRITTEN DISCONNECTS OC P DS PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. QTY. RATED CURRENT MAX VOLTAGE AND WILL BE SUBJECT TO CIVIL 3 SW1 1 SQUARED D223NRB OR EQUIV. 100A 240VAC CB1-4 4 20A 240VAC DAMAGES AND PROSECUTIONS. F1-2 2 70A 240VAC NEW PV SYSTEM: 13.860 kWp ASHRAE EXTREME LOW -10°C(14.0°F),SOURCE:AURORA STATE(45.25°;-122.77°) CBS 1 50A 240VAC ASHRAE 2%HIGH 33°C(91.4°F),SOURCE:AURORA STATE(45.25°;-122.77°) STE F F E N RESIDENCE BILL OF MATERIALS 12647 SW 133RD AVE CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION MODULE MISSION SOLAR MSE385SX5R PM1-36 36 PIECES 1 MISSION SOLAR MSE385SX5R 385W 0 TIGARD, OR 97223 INVERTER APS DS3-S 11-18 18 PIECES 1 APS DS3-S 640W INVERTER APN: 2S104AC03900 4 DISCONNECT SQUARE D D223NRB SW1 1 PIECE 1 SQUARE D D223NRB,FUSED,2-POLE,100A,240VAC OR EQUIVALENT AC COMBINER PANEL GEN-AC-PANEL EP1 1 PIECE 1 AC SUBPANEL WIRING GEN-12-AWG-THWN-CU-RD WR1 180 FEET 1 12 AWG THWN,COPPER,RED(LINE 1) ENGINEER OF RECORD WIRING GEN-12-AWG-THWN-CU-BLK WR1 180 FEET 1 12 AWG THWN,COPPER,BLACK(LINE 2) WIRING GEN-12-AWG-THWN-CU-GR WR1 45 FEET 1 12 AWG THWN,COPPER,GREEN(GROUND) WIRING GEN-4-AWG-THWN-CU-RD WR2-3 2 FEET 1 4 AWG THWN,COPPER,RED(LINE 1) WIRING GEN-4-AWG-THWN-CU-BLK WR2-3 2 FEET 1 4 AWG THWN,COPPER,BLACK(LINE 2) • WIRING GEN-4-AWG-THWN-CU-WH WR2-3 2 FEET 1 4 AWG THWN,COPPER,WHITE(NEUTRAL) ■ WIRING GEN-4-AWG-THWN-CU-GR WR2-3 2 FEET 1 4 AWG THWN,COPPER,GREEN(GROUND) WIREWAY GEN-PVC-40-0.75"DIA WW1 45 FEET 1 PVC-40 CONDUIT,0.75"DIA WIREWAY GEN-PVC-40-1"DIA WW2-3 2 FEET 1 PVC-40 CONDUIT,1"DIA OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC CB1-4 4 PIECES 1 CIRCUIT BREAKER,20A,240VAC OCPD GENERIC MANUFACTURER GEN-FU-70A-240VAC F1-2 2 PIECES 1 FUSE,70A,240VAC 5 OCPD GENERIC MANUFACTURER GEN-CB-50A-24OVAC CB5 1 PIECE 1 CIRCUIT BREAKER,50A,240VAC PAPER SIZE:11"x 17°(ANSI B) TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB-4-4X JB1 1 PIECE 1 TRANSITION/PASS-THROUGH BOX,WITH 4 TERMINAL BLOCKS DESIGN TABLES DATE: 01.15.2023 a ■ DESIGN BY: S.G. CHECKED BY; M.M. 6 REVISIONS E-602.00 A il B is C • D • E • F ■ G is H (SHEET 7) A ■ B ■ C ■ D ■ E ■ F ■ G is H 1 SMART S )LAR • LABELING NOTES ENERGY ■ 1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11,OSHA STANDARD 1910.145,ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. CONTRACTOR 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 2 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8"AND PERMANENTLY AFFIXED. SMART SOLAR ENERGY CO 1.5 ALERTING WORDS TO BE COLOR CODED. "DANGER"WILL HAVE RED O I. C/\U T I 0 N ! BACKGROUND;"WARNING"WILL HAVE ORANGE BACKGROUND;"CAUTION"WILL HAVE 1 YELLOW BACKGROUND.[ANSI Z535] PHONE: 971 645 2487 POWER TO THIS BUILDING IS ALSO SUPPLIED ADDRESS: 10940 SW BARNES RD#250 WARNING RAPID SHUTDOW . ;'„ IN HOTOVI VE TAICOSYSTOEM LTA DIC SCONN CT SYSTEM OLOCA EDD FROM ROOF MOUNTED SOLAR ARRAYS WITH PORTLAND,OR 97225 • ELECTRICAL SHOCK HAZARD g o • LIC.NO.: 234657 SWITCH FOR NORTH SIDE IN THE HOUSE SAFETY DISCONNECTS AS SHOWN: HIC.NO.: TERMINALS ON THE LINE AND DIRECTORY ELE.NO.: LOAD SIDES MAY BE ENERGIZED SOLAR PV SYSTEM PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE PV ARRAY UNAUTHORIZED USE OF THIS IN THE OPEN POSITION DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTINGDRAWING SET WITHOUT WRITTEN LABEL 1 LABEL 5 MEANS IF NOT IN THE SAME LOCATION 5 3/4"X 1 1/8"). PERMISSION FROM CONTRACTOR IS IN ( ) � VIOLATION OF U.S.COPYRIGHT LAWS 3 AT EACH DISCONNECTING MEANS FOR AT RAPID SHUTDOWN DISCONNECT SWITCH(5 1/4"X 2"). [NEC 690.56(B)] FC11.1111.2".'HIAXIIIII:11 � AND WILL BE SUBJECTTO CIVIL - DAMAGES AND PROSECUTIONS. PHOTOVOLTAIC EQUIPMENT(2"X 4"). [NEC 690.56(C)(3)]. WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER,A [NEC 690.13]. DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV 1.111: NEW PV SYSTEM: 13.860 kWp SYSTEM DISCONNECTING MEANS. FRONT /\WARNING PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BACK POWER SOURCE BATHROOMS �� STEEPEN ■ OUTPUT CONNECTION SOLAR PV SYSTEM [NEC 690.4(D),(E)] ,,,, I. == um* • RESIDENCE DO NOT RELOCATE THIS EQUIPPED WITH ,a NIP OVERCURRENT DEVICE RAPID SHUTDOWN PHOTOVOLTAIC POWER SOURCE 12647 SW 133RD AVE LABEL �, _ _ , AT POINT OF INTERCONNECTION UTILITY POLE PV ARRAY TIGARD, OR 97223 EL 9 OVERCURRENT DEVICE(2"X 4"). AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING s APN: 2S104AC03900 4 [NEC 705.12(B)(2)(3)(B)]. SOLAR ELECTRIC 6'( MAIN DISTRIBUTION PV PANELS METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE UTILITY DISCONNECT AC DISCONNECT SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, M OR FLOORS(5 314"x 1 1/8"). N ENGINEER OF RECORD PHOTOVOLTAIC SYSTEM Mill [NEC 690.31(G)] 0 0 POWER SOURCE LETTERS AT LEAST 3/8 INCH;WHITE ON RED BACKGROUND; TURN RAPID SHUTDOWN SWITCH TO REFLECTIVE RATED AC 48.6 AMPS THE"OFF"POSITION TO SHUT DOWN [IFC 605.11.1.1] OUTPUT CURRENT PV SYSTEM AND REDUCE SHOCK TO PV ARRAY 0 NOMINAL OPERATING 240 VOLTS HAZARD IN ARRAY AC 1(Q ACAUTION (E)AUTOMATIC —(N)AC LOAD CENTER TRANSFER LABEL 3 LABEL 6 SOLAR ELECTRIC SYSTEM CONNECTED SWITCH - AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SYSTEM AT DISCONNECTING MEANS(4"X 3"). (3 3/4"X 51/4").[NEC 690.56(C)(1)(A)]. LABEL 10 (N)AC DISCONNECT 5 [NEC 690.54] AT UTILITY METER(5 3/4"X 1 1/8") PAPER SIZE 11"X 17"(ANSI B) /WARNING [NEC 690.56(B)] PHOTOVOLTAIC SYSt DUAL POWER SUPPLY /1\0000::' (E)UTILITY PLACARDS SOURCES:UTILITY GRID SOLAR ELECTRIC METER • DISCONNECT AND PV SOLAR CIRCUIT BREAKER ELECTRIC SYSTEM IS BACKFED DATE: 01.15.2023 LABEL 4 LABEL 8 l % LABEL 7 . ■ AT EACH AC DISCONNECTING MEANS AT POINT OF INTERCONNECTION ' DESIGN BY: S.G. AT JUG POINTc OF INTERCONNECTION CHECKED BY: M.M. (4"X 1") (2 3/4"X 1 5/8"). (2"X 1"). [NEC 690.13(B)]. [NEC 705.12(B)(3)] [NEC 705.12(B)(3)] TO UTILITY 6 EQUIPMENT ELEVATION TO(E)MEP GRADE REVISIONS 0 NOT TO SCALE E-603.00 A ■ B ■ C ■ D ■ E ■ F ■ G IN H (SHEET 8) A is B ni C ■ D ■ E ■ F ■ G ■ H 20 D4 . - � 501 ___-- 1. ® SMART ®_ , S LA R 0001 I - ias:::;::: :;::c:a :t <;:5:::::5::::i ENERGY ��'' _ / 1 1, TJ 00 0 CONTRACTOR 0 /` © SMART SOLAR ENERGY CO 2 RACKING DETAIL (LONGITUDINAL) s PHONE: 9716452487 D2NOT TO SCALE GENERAL NOTES ADDRESS: 10940 SW BARNES RD#250: PORTLAND,OR 97225 • �_ 1. FIELD VERIFY ALL MEASUREMENTS HIC.NO. 234657 ELE,NO,: RACKING DETAIL (TRANSVERSE) DRAWING WUSE OFITHOUT RI D 1 DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN NOT TO SCALE AND WILL BE OSUBJECT COPYRIGHT T O ICIVILLAWS DAMAGES AND PROSECUTIONS. 3 ' 0 0 NEW PV SYSTEM: 13.860 kWp - STEFFEN 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 a 10 1111111111111111111111111111111 0 f_..1 1 I I I I ► 1 I I I I III 1 1 1 & RESIDENCE 1 1 �_i__ 1 0 SHEET KEYNOTES 1 1 1 I I I I 12647 SW 133RD AVE 1. ROOF MATERIAL:ASPHALT SHINGLE 1 TIGARD, OR 97223 1 1 I 1 1 1 I 1 1 1 21 2. ROOF STRUCTURE:TRUSS I I I I I I 3. ATTACHMENT TYPE:SUNMODO SOLOFLASH APN: 2S104AC03900 4 I I I 1 ( I 1 1 4. MODULE MANUFACTURER:MISSION SOLAR 5. MODULE MODEL:MSE385SX5R 11 1111 _ 6. MODULE LENGTH:75.1 IN. ENGINEER OF RECORD I I I I I I I I 1 I I I I I I I I 7. MODULE WIDTH:41.1 IN. I 1 I I I ( I I I I I I I I I I I 8. MODULE WEIGHT:49 LBS. I I I I I I I I I I I I I I I I I I 9. SEE SHEET A-103 FOR DIMENSION(S) 10. MIN.FIRE OFFSET:12"FROM RIDGE,36"FROM EDGE 011. TRUSS SPACING:24 IN.D.C. 12. TRUSS SIZE:2X4 IN.NOMINAL RACKING DETAIL (TOP) 13. LAG BOLT DIAMETER 3i8" D 14. LAG BOLT EMBEDMENT:4" 15. TOTAL#OF ATTACHMENTS:75 NOT TO SCALE ���������������J��������������������� 16. TOTAL AREA:771.65 SQ.FT. 17. TOTAL WEIGHT:1977.7 LBS. 18. WEIGHT PER ATTACHMENT:26.37 LBS. 5 .- - ima win 11 7iimmiis 19. DISTRIBUTED LOAD:2.56 PSF. PAPER SIZE:11^x 17"(ANSI B) 1 ; 20. MAX.HORIZONTAL STANDOFF:48 IN. illiell0. 21. MAX.VERTICAL STANDOFF:IN ACCORDANCE WITH 411111141MIll MODULE MANUFACTURER'S INSTRUCTIONS. ASSEMBLY DETAILS 11," �_��__N_`_�W_�___��1 22. STANDOFF STAGGERING:YES • \\� 23. RAIL MANUFACTURER(OR EQUIV.):SUNMODO DATE: 01.15.2023 ,\ 24. RAIL MODEL(OR EQUIVALENT):SMR100 �� _ �_���t\�t��\ \` 25. RAIL WEIGHT:0.4126 PLF. DESIGN BY: S.G. 26. MAX.TRUSS SPAN:N/A FT. 27. MODULE CLEARANCE:3 IN.MIN.,6 IN.MAX. CHECKED BY: M.M. REVISIONS 6 DETAIL (TRANSVERSE) DETAIL (LONGITUDINAL) D4NOT TO SCALE D5 NOT TO SCALE S-501 .00 A B C D s E ■ F isG ■ H (SHEET 9) A ■ B ■ C • D • E • F • G • H • - 1 SMART . S LAR ENERGY ■ ■ % Class Leading CONTRACTOR MSE PERC 66 MISSION SOLAR ,'�� 375-385W MSE PERC 66 2 ENERGY SMART SOLAR ENERGY CO BASIC DIMENSIONS ELECTRICAL SPECIFICATION (UNITS:MM/IT#] PRODUCT TYPE MSE SX5R(. =Pm.,,) Power Output pm„ we .,E. PHONE: 971-645-2487 Positive - - - Module Efficiency % 18.8 19.1 19.3 ADDRESS: 10940 SW BARNES RD#250 Power Tolerance Tolerance % 0/+3 0/+3 0/+3 Class leading power output 0 to+3% I I 1 I1 1I C',i I Short Circuit Current Ix V 10.85 10.91 10.97 PORTLAND,OR 97225 ■ I 1 Open Circuit Voltage Ve, A 44.64 44.84 45.03 • LIC.NO.: 234657 r e American Q u 1 I ? 'I Rated Current I=; V 10.26 10:34 10.42 HIC.NO.: � I. I I I I I Rated Voltage Vmo V 36.56 36.75 36.93 ELE,NO,: r t e American Bra n c 1 Fuse Rating A 20 20 20 UNAUTHORIZED USE OF THIS I System Voltage V 1,000 1,000 1.000 DRAWING SET WITHOUT WRITTEN I PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS Mission Solar Energy is headquartered in San Antonio,Texas where we I TEMPERATURE COEFFICIENTS AND WILL BE SUBJECT TO CIVIL 3 manufacture our modules.We produce American,high-quality solar modules I C 1 I I Normal Operating Cen Temperature(NOCT) 44.43°C(t3.7%) DAMAGES AND PROSECUTIONS. I ensuring the highest-in-class power output and best-in-class reliability.Our .I , I 1 Temperature Coefficient of Po-lax -0.361%/°C NEW PV SYSTEM: 13.860 kW product line is tailored for residential,commercial and utility applications. I 1 I I: Temperature Coefficient of Voc -0.262%/°C p •Every Mission Solar Energy solar module is certified and surpasses industry Temperature Coefficient of isc 0.039%/°C standard regulations,proving excellent performance over the long term. FRONT VIEW SIDE VIEW REAR VIEW - --- - _-_-_- ----�-- - STEEPEN OPERATING CONDITIONS Demand the best.Demand Mission Solar Energy. CURRENT-VOLTAGE CURVE Maximum System Voltage 1,000Vdc RESIDENCE MSE385SXSR 385WP,66 CELL SOLAR MODULE• Operating Temperature Range -40°C(-40°F)to+85°C(185°F) • Current-voltage characteristics with dependence on irradiance and nodule temperature Maximum Series Fuse Rating 20A Certified Reliability Cells Temp.=25°C Fire Safety Classification Type 1 •• Tested to UL 61730&IEC Standards Incident 2 Front&Back Load Up to 5,400 Pa front and 3,600 Pa 1264 7 S W 133 R D AVE • PID resistant tZ Irrd.=1000 W/m (UL Standard) back load,Tested to UL 61730 �'+• Resistance to salt mist corrosion to TIGARD, OR 97223 Incident 2 Hail Safety Impact Velocity 25mm at 23 m/s Irrd.=800 W/m2 - Advanced Technology i e Incident Irrd.=600 w7m2 APN: 2S104AC03900 �.; MECHANICAL DATA ~ • 6 Busbar lit 4 • Passivated Emitter Rear Contact IC 6 Solar Cells P-type mono-crystalline silicon • • Ideal for all applications Incident Irrd.=A00 W/m2 Cell Orientation 66 cells(6x11) Incident Irrd.=200 W/m2 Module Dimension 1.907mm x 1,044mm x 40mm ENGINEER OF RECORD --ter) Extreme Weather Resilience Weight 22 kg(491bs.) ////;,''3 • Up to 5,400 Pa front load&3,600 Pa back load n Front Glass 3.2mm,tempered,low-iron.anti-reflective %f/ i • Tested load to UL 61730 • 40 mmframe o to m xi ‘in Frame Anodized VOLTAGE(V) --- Encapsulant Ethylene vinyl acetate(EVA) • Junction Box Protection class IP67 with 3 bypass-diodes BAA Compliant for Government Projects CERTIFICATIONS AND TESTS ■ • Buy American Act Cable S.Om,Wire 4mm2(12AWG) FRAME-TO-FRAME WARRANTY IEC : 61215,61730,61701 • American Recovery&Reinvestment Act Staubli PV-KBT4/611-UR and PV-KST4/611-UR, Degradation guaranteed not to exceed 2%In year one and 0.58%annually W. 61730 Connector MC4,Renhe 05-8 from years two to 30 with 84.08%capacity guaranteed in year 25. - - For more information,visit www.missionsolaccom/warranty . (`c f/�"' O SHIPPING INFORMATION `✓E`-' C us Container Feet Ship To Pallet Panels 380W Bin CERTIFICATIONS •x I� o son LISTED 53' Most States 30 780 296.40 kW 5 F�/ IN THE USA Double Stack CA 26 676 256.88 kW PAPER SIZE:11"x 17"(ANSI B) v°^` PALLET(26 PANELS] C EC ITUV CODS If you have questions V V ySUD or concerns about Mission Solar Energy Weight Height Width Length RESOURCE DOCUMENT .e` certification of our LISTED 1274 lbs. 47.56 in 46 in 77 in products in your area, 8303 S.New Braunfels Ave.,San Antonio,Texas 78235 (572 kg) (120.80 cm) (116.84 cm) (195.58 cm) please contact www.missionsolar.eom I info@missionsolar.com UL 61730/IEC 61215/IEC 61730/IEC 61701 Mission Solar Energy. DATE: 01.15.2023 Mission Solar Energy reserves the right to make specification changes without notice. C SA2" )027 ' ?5!05/2021 www,missionsolar.com I info@missionsolaccom C-SA2-MKTG-0027 REFS 25'2021 - ' _m ar i,.r. ar.cam DESIGN BY: S.G. ■ CHECKED BY: M.M. 6 REVISIONS R-001 .00 A ■ B ■ C ■ D 21E ■ F ■ G ■ H (SHEETIO) A a B is C ■ D ■ E ■ F ■ G ■ H -1 SMART S )LAR ENERGY ■ . p p 0 i APsys F}rei f s Leading the Industry in Datasheet 1 DS3 Microinverter Series S ALTENERGY POWER Solar Microinverter Technology Model DS3-S DS3-L CONTRACTOR 2 ` Recommended PV Module Power(SIC)Range 250Wp-48OWp+ 265Wp-570Wp+ 300Wp-660Wp+ SMART SOLAR ENERGY CO DS3Peak Power Tracking Voltage 22V-48V 25V-55V 32V-SSV SeriesOperating Voltage Range { 16V-60V 16V-60V 26V-60V ,.rA Maximum Input Voltage The most powerful Dual !, i 60V -e Maximum input current 16A x 2 18A x 2 zoA x 2 PHONE: 971-645-2487 Microinverter ADDRESS: 10940 SW BARNES RD#250 I it • Qu, rlh,LtOrn>>ert 1 crnn e to tw 5,..)[or module Output Data(AC) PORTLAND,OR 97225 ( • M 1..output n t r,, u ric.4 u40 A 7t,evA ur'Co'.+A Maximum Continuous Output Power 640VA 768VA 880VA • LIC.NO.: 234657 • *'rvl>.,,,,le 7e;n.. -t.t lrpuL,.ha,,,,eI5 MPPT) Nominal Output Voltage/Range* 240V/211V-264V HIC.NO.: • CA Rule 23 i ii.: vI �= crrhiiartt Nominal Output Current 2.7A 3.20A 3.7A • 14E, :020&Cif' R.i rl Shutdo� r 0 m i,.110 ELE.NO.: f P Nominal Output Frequency/Range` �OHz/59.3Hz-60.SHz UNAUTHORIZED USE OF THIS '�� • Ft�c t�tadW Ire =iyl ee Cu),'rt vt.i ..�iicf� PowerFactor(Default/Adjustable) 0.99�0.7leading...0,7lagging DRAWING SET WITHOUT WRITTEN PhR>r Mr=nitr ct a.rl I uve b.:,! �t-U Maximum Units per 20A and 30A Branch** 6/8 5/7 4/6 PERMISSION FROM CONTRACTOR IS IN AC Bus Cable 112AWG/10AWG VIOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL 3 DAMAGES AND PROSECUTIONS. ,Efficiency Peak Efficiency 97% NEW PV SYSTEM: 13.860 kWp CEC Efficiency 96.5% PRODUCT FEATURES NominalMPPTEfflciency 99.5% STEFFEN Night Power Consumption 20mW APsystems 3rd generation of dual microlnverters are reaching unprecedented power outputs of 640VA or 768VA or 880VA to Mechanical Data RESIDENCE ✓ adapt to today's larger power module.With 2 independent MPPT,encrypted Zigbee signals,the DS3-S,DS3-L and DS3 benefit - Operating Ambient Temperature Range -40°F to+1497(-40°C to+65'C) from an entirely new architecture and are fully backwards compatible with the OS1 and YC6OO microinverters. Storage Temperature Range -40°F to+185°F(-40°C to+85°C) The innovative and compact design make the product lighter while maximizing power production.The components are encapsulated with silicone to re- Dimensions(WeHxD) 10.3"x 8.6"x 1.6"(262mm X 218mm X41.2mm) 12647 SW 133RD AVE duce stress on the electronics,facilitate thermal dissipation,enhance waterproof properties and ensure maximum reliability of the system via rigorous Weight 5.71b5(2.6kg) TIGARD, OR 97223 testing methods including accelerated life testing.A 24/7 energy access through apps or web based portal facilitate remote diagnosis and maintenance. DC Connector Type MC4 The new D53 series is interactive with power grids and fully compliant with CA Rule 21 requirements,to better manage photovoltaic power spikes in Cooling Natural Convection-No Fans APN: 2S 104AC03900 4 the grid.With a performance and an efficiency of 97%,a unique integration with 20%less components,APsystems DS3-5,DS3-L&DS3 are a game Enclosure Environmental Rating NEMA 6 changer to residential and commercial PV. ENGINEER OF RECORD Communication(Inverter To ECU) Encrypted ZigBee Isolation Design High Frequency Transformers,Galvanically Isolated WIRING SCHEMATIC Energy Management Energy Management Analysis(EMA)system Warranty"' 10 Years Standard;25 Years Optional ■ / \ / \ / \ . r \ / \ / \ ■ Compliance Safety and EMC Compliance UL1741;CSA C22.2 No.107.1-16;CA Rule 21(UL 1741 SA);FCC Part15;ANSI C63.4;ICES-003;IEEE1547;NEC2014&NEC2017 Section 690.11 DC Arc-Fault circuit;Protection NEC2014&NEC2017 Section 690.12 Rapid Shutdown of PV systems on Buildings;NEC 2020 -L „ 5 -�= t�- F 'Nominal voltage/frequency range can be extended beyond nominal if required by the utility. ®All Rights Reserved 5 -1/I Fl(� J'µ/(J "Limits may vary Refer to local requirements to define the number ofmic o nve ers per brooch most renhons subject a change without nat ce please n.conl sure you are using the �s ri in yourarea. most recent update found at web:usa.APsystems.cora PAPER SIZE:11"x 17"(ANSI B) _____` f _._.._ ,-�_ ` `• •`To be eligible for the warranty,APsystems microinverters need tobe monitored �.k _.-,. ♦ via the EMA portal Please refer to our warranty T&Cs available on psa.APsystems.com. L_ , �� ` _ RESOURCE DOCUMENT L�-_-'_ _,m_ APsystems co Meets the standard requirementsr EAR 600 Ericksen Ave NE,Suite 200 Seattle,WA 98110 ® for Distributed Energy Resources 9 ,mot, Tel:844-666-7035 (UL 1741)and CSA Listed Markenufied with the LJ apsystems.com C US DATE: 01.15.2023 2021/08/28 Reel.1 DESIGN BY: S.G. I CHECKED BY: M.M. REVISIONS 6 R-0 0 2.0 0 A mB • C • D • E • F mG ■ H (SHEET it) A ■ B ■ C ■ D ■ E . F ■ G ■ H 1 A Cut Sheet SMART ivi Swv i k S LAR ENERGY ■ SMR100 Rail ■ SMR100 Rail a Li - CONTRACTOR SMART SOLAR ENERGY CO 2iiiiiil in PHONE: 971-645-2487 t ADDRESS: 10940 SW BARNES RD#250 PORTLAND,OR 97225 l ■ LIC.NO,: 234657 ■ HIC.NO,: ELE,NO.: UNAUTHORIZED USE OF THIS ( _m DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS Mechanical Properties Section Properties AND WILL BE SUBJECT TO CIVIL 3 DAMAGES AND PROSECUTIONS. Material:6005-T5 Aluminum Sx:0.196 in3(3.21 cm3) Weight:0.4126 lbs/ft(0.614 kg/m) Sy:0.146 in3(2.39 cm3) NEW PV SYSTEM: 13.860 kWp Ultimate Tensile Strength:37.7 ksi(260 MPa) Area(X-section):0.352 in2(2.27 cm2) T �� Yield Strength:34.8 ksi(240 MPa) S 1 E E N SMR200 Rail � �;� t SMR200 Rail RESIDENCE 12647 SW 133RD AVE ill, i --i L -7 r TIGARD, OR 97223 (... APN: 2S104AC03900 4 ,/� M ENGINEER OF RECORD II gall 5 PAPER SIZE:11"x 17"(ANSI B) Part Number Description Mechanical Properties Section Properties RESOURCE DOCUMENT A20422-168-BK SMR100 Rail,Black Anodized, 168" Material:6005-T5 Aluminum Sx:0.223 in3(3.74 cm3) Weight:0.453 lbs/ft(0.626 kg/m) Sy:0.189 in3(3.10 cm3) Ultimate Tensile Strength:37.7 ksi(260 MPa). Area(X-section):0.388 in2(1.22 cm2) DATE: 01.15.2023 A20431-168-BK SMR200 Rail,Block Anodized, 168" Yield Strength:34.8 ksi(240 MPa) DESIGN BY: S.G. IN ■ A20440-BK1 SMR100 Rail End Cap,Black CHECKED BY: M.M. A20440-BK2 SMR200 Rail End Cap,Black D10225-V001 REVISIONS Dimensions shown are inches Ions millimeters) Details ore subject to change without notice 6 R-003.00 A ■ B ■ C is 0 ■ E • F • G ■ H (SHEET 12) A is B IN C ■ D ■ E ■ F is G ■ H .1 S U N M A Cut Sheet SMART �■r - S LA R 11 ENERGY 1.SoloFlash ' __r ■ ■ Material:Aluminum SoloFlash TM Finish:Silver or Black Powder Coating CONTRACTOR SMART SOLAR ENERGY CO 2 t o 0 Q PHONE: 971 645 2487 ADDRESS: 10940 SW BARNES RD#250 2.L Foot PORTLAND,OR 97225 I°,om i ■ LIC,NO.: 234657 • HIC,NO.: ELE.NO.: s s UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN ai PERMISSION FROM CONTRACTOR IS IN L I VIOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL »o DAMAGES AND PROSECUTIONS. 3 i NEW PV SYSTEM: 13.860 kWp I 1 r 8 I. ,OU Material:Aluminum STEFFEN ■ - • RESIDENCE 3.EPDM Gasket Part Description: SoloFlash, Silver 12647 SW 133RD AVE Part No•: K50538-003 TIGARD, OR 97223 APN: 2S104AC03900 Material:USWR EPDM Gasket 4 Part Description: SoloFlash, Black with Adhesive Part No.: K50538-BK3 F` ENGINEER OF RECORD 4. Hex Lag Bolt M8X115,DIN 571,304SS ,x0 Item Description Qty in — ,,.z.1; ■ No. Kit ' -- ■ `- u 1► iti'11til 1 1 Flashing,9"X12" 1 _ •. i Material:Stainless Steel • Finish:Clear 2 L Foot Assembly 1 5 • L Foot PAPER SIZE:11"x 17"(ANSI B) • EPDM Gasket with Adhesive 5.Sealing Washer.33ID X.75X.157 RESOURCE DOCUMENT 3 Lat Bolt Assembly 1 DATE: 01 15.2023 • Hex Lag Bolt M8X115,DIN 571,304 SS / DESIGN BY: S.G. ■ • Sealing Washer.33 ID X.75 X.157 IN,_ CHECKED BY: M.M. Material:EPDM+Stainless Steel REVISIONS 6 Dimens-V003 Dimensions shown are inches and millimeters) Details ore subject to change without notice R-004.00 A ■ B ■ C • D In E IN F ■ G ■ H (SHEET 13) A ■ B • C • D ■ E • F • G • H Product data sheet D223NRB SMART Characteristics SWITCH FUSIBLE GD 240V 100A 2P NEMA3R S LAR ENERGY II Product availability:Stock-Normally stocked in distribution facility Price* :480.00 USD CONTRACTOR 2ir SMART SOLAR ENERGY CO �P. PHONE 971-645-2487 ADDRESS:10940 SW BARNES RD#250 PORTLAND,OR 97225 • I LIC.NO.: 234657 i HIC.NO.: ELE.NO.: UNAUTHORIZED USE OF THIS , DRAWING SET WITHOUT WRITTEN ' PERMISSION FROM CONTRACTOR IS IN 3 VIOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.860 kWp Main 1 STEFFEN Product or component type Single Throw Safety Switch 8 RESIDENCE Line Rated Current 100 A Product certifications UL listed NEMA degree of protection NEMA 3R X 12647 SW 133RD AVE Disconnector device type Fusible disconnect TIGARD, OR 97223 4 Device composition Neutral(factory installed) APN: 2S104AC03900 0 Short-circuit current 100 kA maximum depending on fuse H,K or R m 1 Device mounting Surface ENGINEER OF RECORD Number of poles 2 Electrical connection Lugs II Series name General duty ° N Ordering and shipping details Category 00106-D&DU SW,NEMA3R,30-200A m Discount Schedule DE1A 5 ° GTIN 00785901460701 PAPER SIZE:i i"x 17"(ANSI B) Nbr.of units in pkg. 1 a 0 Package weight(Lbs) 15.460000000000001 s RESOURCE DOCUMENT Retumability yse Country of origin US o DATE: 01.15.2023 N IIDESIGN BY: S.G. Contractual warranty y CHECKED BY: M.M. 6 Warranty period 18 months a REVISIONS N A B an ■ R-005.00 C D ■ E • F G ■ H (SHEET 14(