FP5223 - o®a55 RECEIVED cl .Y 3 2923 iiif+4 tail“.*,i;%4C-4;k1- WYArG gg.s„: i # # FIRE PROTECTION, INC. 9095 S.W. Burnham } Tigard, OR 97223 STARBUCKS 1 -5 AND CARDINAL 6600 SW CARDINAL LN TIGARD, OR 97224 FIRE PROTECTION EQUIPMENT SUBMITTAL tIICLJ Worldwide Fire Protection Contacts www.tyco-fire.com Products _, Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers Description described herein must be installed and maintained in compliance with this doc- 1 ` The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright (TY313) and Pendent (TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition to the stan- lea --• are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair sprinklers designed for use in light or the performance of these devices. ordinary hazard,commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a _' any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Sprinkler Escutcheon with recessed adjust ment up to 5/8 inch (15,9 mm) from Identification '^ ., the flush pendent position. Number (SIN) y • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) 175°F(79°C) Intermediate level versions of Series Approvals 200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi (12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories, Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi112(80,6 LPM/bar112) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 - 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* I — 1 5 7/16" (11,1 mm) \ — 4 NOMINAL 2" 1 Il MAKE-IN (50,82 m'm) t T--) 2 2" 1-3/8" (50,8 mm) I (34,9 mm) 3 WRENCH 1 t / FLATS 1/2" NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. --- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE C. Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. ....."11/. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install anybulb-type ype sprinkler if ' W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air bub- WRENCH Criteria ble should be present. The diameter RECESS of the air bubble is approximately 1/16 The TYCO Series TY-FRB,5.6 K-factor, inch (1,6 mm)for the 135°F(57°C) and Upright(TY313) and Pendent (TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. 4/i '- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min- Approval agency (such as, UL Listing imum to maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels *r, t 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment IN TO ENSURE Data Sheets).Only the Style 15 or Style of the sprinkler. ENGAGEMENT 20 Recessed Escutcheon is to be used Do not attempt to compensate for WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8" DIA. _ sprinkler fitting using only the W-Type (73,0 mm) — 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4" DIA. Sprinkler Wrench to the wrench flats. FACE OF ~ (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs. (9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers , FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" ,,� I Sprinklers must be installed in accor- (9,5±7,9 mm) `; - % t dance with the following instructions. } / / Step A.After installing the Style 15 or MOUNTING 1/8 i Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread — i sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm) sprinkler fitting. FIGURE 4 Step B.Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque —___2-7/8" DIA. -- sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF SPRINKLER 2-1/4" DIA. ---1Step C.After ceiling installation and fin- FITTING (57,2 mm) 1 ishing,slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- 5/16±1/4" 1/2" mm) kler and push the Closure over the (7,9±6,4 mm) (12,7 Mounting Plate until its flange comes in + FLUSH contact with the ceiling. _ 7 Care and 1/$, MOUNTING (3,2 mm) Maintenance SURFACE The TYCO Series TY-FRB,5.6 K-factor, Upright(TY313) and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. if they cannot be completely cleaned Absence of the outer piece of an by wiping the sprinkler with a cloth or Automatic sprinkler systems are rec- escutcheon, which is used to cover by brushing it with a soft bristle brush. ommended to be inspected, tested, a clearance hole, can delay sprinkler and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ slippage,or the like, must be replaced. cleaned by means of gently dusting with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad cracked bulb or that has lost liquid from vertent operation may result. its bulb. (Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)°° 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER *Use suffix"I"for ISO 7-1 connection: 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I **Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify)Sprinkler, SIN (specify), K=5.6, Quick Response, (specify)tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify") Specify: Style 20 Recessed Escutch- eon with(specify*)finish, P/N(specify") Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t yco TEFLON is trademark of The DuPont Corporation. '7 Fire Protection Products Fire Sprinkler Pipe Schedule 10 and Schedule 40 Submittal Data Sheet FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm in. mm in. mm lbs./ft. - kg/n CRR' Lift Approvals and Specifications Both products meet or exceed 13/4 1.660 422 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 the following standards: 7 Y: 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 • ASTM A135,Type E,Grade A(Schedule 10) 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 • ASTM A795,Type E, Grade A(Schedule 40) 2'/z 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 • NFPA 13 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected 4 4.500 114.3 4:260 108.2 .120 3.05 5.62 8.37 1.6 19 to the toughest possible testing protocols to 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 ensure the highest quality and long-lasting performance. 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Finishes and Coatings All Wheatland black steel fire sprinkler pipe 'Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. *The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. up to 6" receives a proprietary mill coating to Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). ensure a clean,corrosion-resistant surface that outperforms and outlasts standard lacquer coatings.This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS easily painted,without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black,or with hot-dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES FM/UL requirements for dry systems that meet in. mm in. mm in. mm lbs./ft. kg/rn CRR' Lift the zinc coating specifications of ASTM A795 or A53.All Wheatland galvanized material is 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 also UL Listed. 1Y4 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 Product Marking 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 Each length of Wheatland fire sprinkler pipe is continuously stenciled to show 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 the manufacturer,type of pipe,grade,size 'Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. and length. Barcoding is acceptable as a 'The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). supplementary identification method. Oct 411:1111. APPROVED SUBMITTAL INFORMATION PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: ❑ BLACK ❑ HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon, PA 16146 Wheatland Tube P 800.257.8182 I F 724.346.7260 I info`a;wheatland.com I wheatland.com M F FL �oU Ductile Iron Threaded Fittings A„..... .. ., ,„.. - -„,,,A. k ry e A., :. ..., „ , ,....... ... ,..,„,,,. p „, Jr Yf iiiiiiiii . ... . ,, . e } T p k CAI Ductile Iron Threaded Fittings • branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C L US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 441> • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300#Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 420 400 400 450 f0 500 360 550 340 600 320 0 300 Ductile Iron Fittings - Class 300 UL/FM - ._ c ® us 4.71> APPROVED Fig. 35E 3-90°Elbow LISTED Size Part Number A Packing Weight Ib yin ginner Master - tb iii: 1/2 35E 3004 1 13 100 200 0 2 i 314, 2 0 1` 1 7 140 : 0 -:. A 1 35E 3010 1.50 40 80 0.5 !11.1 1'I/4 35 3112 - .176f 5( .,. 6. -- 1-1/2 35E 3014 1.94 18 36 1.1 3026 ,.; 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3_2 Fig. 35RE3-90°Reducing Elbow B Size A B Packing Weight Pr inart Number in in inner , Mauer lb I 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2-. _ 3��1t 4.. 1,26 '1:36 10 ''- 140 0.4 I ISI --- 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 11111 � A 1-1/4'x 1/2 3 3012004' -1.34' 1.5-i 35 70 0.5.:.- 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-114 x 1 35FIE$012016 ' 1,58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2:x 314 35R53014006' 1.52 1.75 25 -. 50 ;` ,0,7, 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4- 3 R 14012 1.82 .1.88 - % 18, „ 36 1' 1.0 :-::: 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 :' .3 E30 0006 ' 1.60 , 1.97" ''18 86 1,0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 X 1.114 R3 012 , 1. 0 2.10 12 - ,`, 24` ` 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2' 3 153024014 2.16 2.51 6 , 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow E Size Part Number A Packing Weight \ in in inner Master ►b j 1/2 35F 3004 0.88 150 300 0.2 till 334 '�. 0.98 800 , 160 ;..0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 , 35F 3012 1; 9' 2 > 0 7, knit �A 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020-- 1 9 10 20 1>6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee 01 Sizein Part Number i An Inner PackingMaster Weightzil tw A 1/2 35T 3004 1.13 80 160 0.3 -11 30 . 1 1 351 3010 1.50 25 50 0 7 .. ill 1-1/4 35T 3012" ..- 1.75 10 20 .s11 '' A 1 A 1-1/2 35T 3014 1.94 10 20 1.5 111111 35T 2.25 12,r.. .4 2-1/2 35T 3024 2.70 4 8 4.3 ; 111 SNIITII-COOPER IN7'ERNAi'IONAL® • 'TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Ductile Iron Fittings- Class 300 UL/FM TY c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED Size A B C Packing Weight Part Number ;a� in in in in inner Master lb C 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004:. 1.26 1:26 1.36 , 30 60 , 0.6 -�_--1- I- 1 x 1/2x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 � 1 .. ......:. ... I 1 x 3/4 5RT3010006 1.38 . 1,88.. 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B F A 1 x 3/4 x 1 35RT3010006010 ,. 1,50 1.45 . 1,50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 . 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 3514T3012006012 , 1.75 1.62 1,75 20 40 . 1,0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35B13012010004 1,34 1.26 1,53 25 50 0.7= 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0,9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1,66 1.94 12 24 ' 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1141 35RT3014006012 1.94 , 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 _ 1-1/2 x 1 ' 35813014010 1.65 1.65 1.80 12 24 1,2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 ' 35RT3014010006 1,50 1.44 1,75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x 1 x 1-1/4 35R1301401 12' 1,82 167 1.88 12 24 1.2 -= 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1,82 1.88 12 '° 24 1.4 t =.I, 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1 1-1/2x -1/4x3/4 ; 35R13014012006 1.52 1.45 1.75 18 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x'1-1/4x 1-1/4.35RT3014012012 1.82 1.75 1,88 14 28 , 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 ,,' 2'x 1/2 , 35RT3020004 1,49 1,49 1.88 10 20 ' 1,5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x 1 35113020010' F 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35R13020012 10 1.90 2,10 8 ,16 1.9 .: 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 - : 2,02 ,, 2.16 8 16 -'= 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4; 35R13020014006 1.60 1,52 1.97 ' 10 20 , 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 xi-1/4 .,3 RT3020014012 1,90 1,82 2.10 8 16 1,7 1 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size Part"Number - "A B "C " " Packing Weight i .►��t C in in in in Inner Master lb 3/4 x 1 35B13006010 1.45 1.45 1.37 30 60 0.6 • I 1 a 1-1/4 - 356T3010012 1,67 1.67 1.58 20 40 _ 0.9 ; 1 x 1 1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A B 1-1/4x 1 x 1-1/2 35813012010014 1,88. 1.80 , 1.82 15 30 '1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 ' 351 T3012020 '2.10 2.10 1.90 : ' 10 ' " 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 813014020 ,;2.16 ; :2.16 2,02, 8 . '16 , 1.8 - SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com 112 Ductile Iron Fittings - Class 300 UL/FM 1-(1144TY' n4%1'; c CD) us 4j> APPROVED LISTED A Fig. 35CP3 —Straight Coupling with Ribs 0 Size A Packing Weight FlPart Numberi n , to Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 1 350P3010 1 75 60 120 0.4 1-1/2 35CP3014 2.19 25 50 0 7 2-1/2 35CP3024 3 00 9 18 2 2 111 Fig. 35RC3 —Hex Reducing Coupling lSxiinze Will A 1 x umber A Packing Weight ilaiiili - I Part Nu in 3/1/42 35RC301000435Ftc301 169 Inner Master lb 0008 80 160 0.3 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2 06 40 80 0 6 2 x 1 (not hex) 35P03020010 2.81 20 40 to Fig. 35HB3 —Hex Bushing Size A Packing Weight Part Number B In in Inner Master lb , ) 1 x 1/2 35HB3010004 1 06 180 360 0.2 1 x 3/4 35HB301.0006 1 1-77 1 ^A 1-1/4 x 1 90 1 : I i 35HB3012010 1 19 180 0.2 I I - 1-1/2 x 1 35H83014010 1.25 75 150 0,4 1-1/2x 1-1/4 35HB3014012 1.25 75 150 0.3 - 3 4 .,4 2x 1 35f-83020010 - 1.38 40 80 0,6 ,---,1 ;2 2 x 1-1/4 35HB3020012 1.38 40 80 0 6 2 x 1-1/2 351413020014 .,. 1.38 40 80 OM -'k Fig. 35SP3 —Square Head Plug Size ' A Packing Weight Part Number in in Inner Master lb - 1/2 35SP3004 0 94 600 1200 0 07 A 3/4 355P3006 1.12 350 700. 0.1 1 35SP3010 1.25 200 400 0.1 1-1/2 35SP3014 1 44 80 160 0.4 2 35SP3020 1.50 45 90 06 ., Fig. 35U 3—Union with Brass Seat . A Size A Packing Weight ) Part Number .Rim in in Inner Master lb ,,... wilimentsum 1 35U 3010 2.19 20 40 1 0 ,--- 1-1/4 I 35 3012 250 1512 II U ' 30 . 1-1/2 35U 3014 2.62 10 20 1 7 sathermean 2 35U 3020 3,42 6 12 2.4 . brio 113 SNIITII-COOPER IN'EERNNI'IONAL" • 'VOLE FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com . ' Ductile Iron Fittings - Class 300 UL/FM t,-x -' c ® us APPROVED LISTED Fig. 35X 3— Cross E A 'I A Size A Packing Weight Part Number �i j in in Inner Master lb x�� I IA 1 35X 3010 1 50 20 40 0 9 ;� -- I — 1-114 .€ 35:301 1,70 ' 12 1.4 1 1/2 35X 3014 1 94 8 16 1.8 ,4 �� IA 2.. 35X 3020 2.25. 6 12 2,8, f B B Fig. 35RX3—Reducing Cross Size A Et packing Weight Part Number ow.��■'�'1 A in in in Inner Master lb 1 1 1/4 x 1 35RX3012010 1 67 1 58 15 30 1.2 I --i-- 1--E12 x 1 35RX3014010 1.80 1..55 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. Size35C3— Cap Packing Weight in Part Number iAn Inner , Master lb A 1/2 35C 3004 0 87 300 0 0.1 3/4'; 35G 30 06 1 35C 3010 200 4060 0.1 I 1.1 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 350 3014 1.33 50 100 0.5 2 i 35C35C 30203024 1.45 215 50 0 8 1/2 1.70 2 18 36 1.6 Fig. 35BC3—Beam Clamp �/ Size Part Dumber A Packing Weight in inner Faster ih AlI III3/8 35BC3003 0.75 100 20003_ �i 112; 358C3004 0.7 80 180 0.5 1. SMITH-COOPER INTERNATIONAL`' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.srnithcooper.com 114 IPS PARBQN TEEI pIPE CUT P QDUc _ w "' °� US ® vas LPCB ire_ LISTED 491a/27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating/, 3/4, and 1'/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples,sprigs,gauges,drains and other outlet products.Available for 1'A through 76.1 mm/32 to 76.1mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade "E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com IT'S CARBON STEEL PIPE - IOi_F.CUT PRODUCTS 10.52 . - e : STYLE 922 DIMENSIONS Nominal Size Hole Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each Run & r. r s '/4 X Yz 3/16 1.30 1.83 11046.5 3.87 2.56 0 V ^� all t 32 15 30.2 33.0 183 11027.9 98.3 65.0 0.45 �\ T ��" 4 3/16 1.28 83 10 3.87 2.56 1' ` 20 30.2 32.5 46.5 27.9 98.3 65.0 1.1 0.50 `,;� ��� 1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 - cell 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1/z X 1/21 3/16 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1,64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 X 1/2 1 3/16 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 ' 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 X 1/2 13/16 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3 1 3/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/2 1 3/16 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 : 13/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com ‘ /r_ta dire' IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 FireLock''' Outlet-T STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per iL Run Size x Outlet Size 213,SectIon lot(C=120(*,FT Inches/ram Feethneters 1 x 1 8 5 32 25 2.6 1 1/2 1 8.5 40 25 2.6 2 x 1 8.5 50 25 2 6 21/2 x 1 8 5 65 25 2.6 1 8.5 76.1 mm X 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com II.r_® .52 IPS CAI3BONST PIP .: Ql C 1i9DUCTS s ,: 0 • it r I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 drtau iI.f Pipe Hangers Fig.200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) ®Tt .CC7ry Fig. 200F- "Trimline" Adjustable Band Hanger with Felt lining (B-Line Fig.B317ONFF) b C)1X Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) USTED • Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications A. Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: / • (1/2" (15mm) thru 2" (5omm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion.Captured design , 1 keeps adjusting nut from separating with hanger. Hanger is easily ti i , B - installed around pipe. For hanger with non-captured nut order Fig. 200S. n j • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. i Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) I Fi 200-1/2.200-3/4 in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and r g Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). Fig.2gg-1to200-2 Fig.2g0-21hto200-8 Conforms to Federal Specifications WW-H-171 F &A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F (343°C) - Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts ail. _ in place of a knurl nut. t Order By: Figure number and pipe size Designed to meet or exceed requirements of .7 FM DS 2-0. be� ,` Fig.200 Fig.200C Fig.200E Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2", (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) '. 200-3/4 3/4" (20) 3/8'-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) ,1 200-11/4 11/4" (32) 3/8'-16 33/4" (94.0) 27/8" (73.01 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) , 200-2 2" (501 3/8"-16 41/2" (114.3) 3" (76.31 15 (6.9) 200-21/2 21/2" (65) 3/8-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" 1101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8-16 73/8" (187,3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5 (127.0) 35 (16.0) 200-5 5" ; (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"13 131/a" (333.4) 83/4" 1222.2) 136 . 162.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. „ Fire Protection Solutions B-Line 21 by EIT.N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCo Fig. 103) --'-� 63205E - Threaded Rod (right& left hand threads) i TL Specify Length '� Size Range: 3/8"-16 thru 3"-4 rod 'L' - Material: Steel �' Function: Recommended for use as a hanger support in hanger assemblies. TL 111111 Rod is threaded on both ends with right hand threads of the length shown.Also 1111h1�� A available with left and right hand threads-specify Fig. B3205L when ordering. • Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B -VS x t' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 8 -1/2 xi'L' 1/2°-13 21/2' (63.5) 1350 (6.00) 1057 (4.70) 83 -518x'L' 5/s"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52)a 83205.N4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 63205•1/8.x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) WWI,x'1? 1 -8 4" (101.6) 5900 (26.24) 4620 (20.55) 832041I8 x'(.' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 _ (25.93) $�- xL 1'I4 ' ' 11I4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) 03 _1112 x',L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 83205-1314x'L' 13/4 -5 7° (177.8). 18600 (82.73) 14566 (64.79) 83205-2,x:.*I' , 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 0.541_141c`L' 21/4"-41I2 9° (228.6) 32300 (143.67) 25295 (112.51) 83' - 12,.X'' . 21/2°-4 10" (254.0) 39800 (177.03) 31169 (138.64) 5r 141t`1' - 23/4"-4 11" (279.4) 49400 (219,73) 38687 (172.08) 05- xV- 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) �q Fig. 99 - All Threaded Rod Cut To Length „„ * Size Range: 3/s"-16 thru 11/2"-6 rod in 120" (3.05m)lengths or cut to length i Material: Steel ���11� i d Maximum Temperature: 750°F(399°C) . o . Finish: Plain. Contact B-Line for alternative finishes and materials. 0 Order By: Part number, rod diameter and finish 4-a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) AtR / ' 1/4, � 20 240 (1.07) 12 (5.44) ! 'X 1 9 'x 16 730 (3.24) 29 (13.15) t 13 1350 (6.00) 53 (24.04) `- .TR ale it 1 - 0•4/8"=x 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 /4"x knit& b 10 3230 (14.37) 123 (55.79) TRT/8"o 1 - o)x o 9 4480 (19.93) 170 (77.11) AIR 1"x 12# - n x l� - 8 5900 (26.24) 225 (102.06) - All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B- ine - Pipe Hangers&Supports 236 Revised 4/28/2014 by Victaulic® VicFlexTM Sprinkler Fittings ✓�taul;c' Series AH2 and AH2-CC Braided Flexible Hoses 10.85 FIexTM Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830mm. Note: length includes adapter nipple and 5.75"/140mm straight reducer. • Series AH2-CC 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 727790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. • Sprinkler Reducers: • Sprinkler Connections: 1/2 and 3/4"/15 and 20 mm • Straight Lengths: 5.75, 9, 137140, 230, 330 mm • 90° Elbows: • Short (typically used with concealed sprinklers) • Long (typically used with recessed pendent sprinklers) • Low Profile Short (for use with Style ABS, AB11, AB12, ABBA and ABMM Bracket) • Low Profile Long (for use with Style ABS, AB11, AB12, ABBA and ABMM Bracket) • Inlet Connections: • 1725 mm Grooved IGS • 1"/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • 3/4"/20mm NPT or BSPT adapter nipples available for VdS. • 1 1/47 32 mm BSPT adapter nipples available for LPCB. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. 'Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All fights reserved. victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) • Brackets: • Style AB1 for suspended and hard-lid ceilings and sidewalls, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard-lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong® TechZoneT' ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 471.00mm. • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) Connections • To adapter nipple (inlet) via • 1"/25.4mm Grooved IGS • 1"/25.4 mm NPT or BSPT male thread • 3/4"/20 mm BSPT male thread (VdS only) • 11/4"/32 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via 1/" or 3/4/15 mm or 20 mm Minimum Bend Radius • 7"/178mm (FM/CCCf Approval) • 2751 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (1 715mm reducer) K5.6/8,1 (S.I.), (3/4"/20mm reducer) K14.0/20,2 (S.I.) • cULus (1/2"/15 mm reducer) K8.0/11,5 (S.I.), (3/4"/20 mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2'/15mm reducer) K5.6/8,1 (S.I.), (3/4'/20mm reducer) K8.0/11,5 (S.I.) 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaullc Company.All rights reserved. / _ victaulic.com 2.0 CERTIFICATION/LISTINGS ® cOus [vdsJ LPC 1 LISTED NOTE • The VicFlex Series AH2 Hose has been tested and evaluated by Spears®for acceptable use with Spears®CPVC Products and is therefore covered under the Spears®FlameGaurd®Installer Protection Plan. 3.0 SPECIFICATIONS — MATERIAL • Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (l "/l5 mm or 3/4"/20 mm): Carbon Steel, Zinc-Plated • Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Coupling Retainer Ring: Polyethelene • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2715 mm or 3/"/20 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 • Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest V Ct=a i, G,Jsket Seieitoi% ,,de for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. • victaulic.com _ . • 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose Item Description 1 _.. Flexible Hose I 0 2 Isolation Ring 6 ® ® ® ® ® 3 Gasket I 4 Nut iiiiit i ��1�' 5 AdapterNipple � 6 Braid 7 r Collar/Weld Fitting _. Sleeve • Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31/790 i 25.3/641 31/790 36/915 31.3/794 36/915 48/1219 n 42.3/1073 E : 48/1220 60/1525 54.3/1378 60/1525 72/1830 66.3/1683 i 72/1830 Series AH2-CC Braided Hose 0 Item Description - 0 © 0 p A ® -CD1 1 Flexible Hose .siib ., 2 Isolation Ring IIOI,I _.III I-Ciii iiiiunwifYl�R9YB9 3 Gasket —i �1��� unununuwuuuuuuwi��� 4 Nut_ I ill ,. 5 Captured Coupling_ —_ A B > 6 Braid 7 Collar/Weld Fitting 8 ..__ __. Sleeve __... I Hose Length A B inches inches inches imm mm mm 1 31/790 i 24.5/622 LL 29 8/757 36/915 29.5/749 34 8/884 _ __ I 48/1219 41,5/1054 468/111189 60/1525 53.5/1359 58.8/1494 I E _ 72/1830 , 65.5/1664 ry 70 8/1798 . • 10.85 5839 Rev AG Updated 07/2019 ©2019 Vlctaullc Company.All rights reserved. victaulic.com • 4.0 DIMENSIONS (Continued) Standard Reducer III IIIII III IIIII III IIIII III IIIIII 5.75"/140 mm straight reducer Optional Reducers L-- 9.0"/229 mm straight reducer Ci — — 13.07330 mm straight reducer 2.627 665 mm I -- 2.62"/ - [ 62. rnm 6.57"7 166.9 mm 4.83"/ _ _ 122.7mm LpJ Short 90°elbow reducer Long 90°elbow reducer NOTE • The Short 90°elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile Al I 0 III ' I'. _ = 459"/ = 116mm _ = 2.84"7 = _ _ = 72 Imm = _ • L 1.4'7 1.4"/ 36 mmJ 36 mm • --> Short 90°elbow reducer Long 90°elbow reducer NOTE • Style AB1.1:When low profiles elbows are used with the Style AB11.bracket,the Low Profile Short Elbow is typically used with concealed sprinklers while the tow Profile long Elbow is typically used in the installation of recessed pendent sprinklers. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. . victaulic.com 4.1 DIMENSIONS _ VicFlex Brackets _ Style AB1 3 • Suspended Ceilings • Hard Lid Ceilings (FM Only) 1,1 Item I Description 1 0 r 0 1 24/610 m m or 48/1219 mm Square Bar 2 I Patented Center Bracket %�� 3 End Bracket I 0 NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed A jø il) Style AB2 • Suspended Ceilings • Hard-Lid Ceilings A Item Description p 1 241610mmor4811219mmSquareBar ; ,l/os 2 Patented Verticallustable Center Bracket , Y �� _ 3 1 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed • IP\i I9 Style AB3 i� • Surface Mount Applications /0,8 • FM/LPCB Approved I — Q, �� 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. _ victaulic.com • • 4.2 DIMENSIONS VicFlex Brackets Style AB4 • Hard-Lid Ceilings with Hat furring 2 channel grid system 3 Item Description i 1 ' 24 f610mm or48/1219mm Square Bar 3 _2 i Patented Vertically Adjustable Center Bracket 3< End Bracket for Hat t`urrin Channel NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed. Style AB5 • Hard-Lid Ceilings ', Q i Item Description 1 24/610mm or48'71219mm Square Bar 2 Patented Vertically Adkustable Center Bracket 3 End Bracket O t.. .., 2 NOTE i • Both sizes FM/VdS/LPCB Approved,cULus listed. 3 . �i j� Style AB7 • Suspended Ceilings 3 • Hard-Lid Ceilings H'- Item i Description _.._ 1 i 24/610 gun or48'/1219mmSquare Bar ., 2 I Patented 1 Bee2°Center Bracket �� � 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. �� rr� in Style AB7 Adjustable 4, • Suspended Ceilings 3 .ice • Hard-Lid Ceilings iil Item Description 1mm I 700mm or 1400mm Square Bar ..__ z 2 Patented 1 Bee2®Center Bracket 3 i End Bracket(adjustable) _ NOTE • Both sizes FM/VdS/LPCB Approved. `� jil%0 OD Fr 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.Ali rights reserved. • . . .. , - victaulic.com 4.3 DIMENSIONS VicFlex Brackets - Style AB8 \� 0 • Hard-Lid Ceilings 6 Item l Description 1 1 700 mm or 1400 mm Square Bar ] *,:k . 2 ` Patented Vertically Adjustable Center Bracket 3 End Bracket i�i NOTE r\= • Both sizes FM/VdS/LPCB Approved. \,\. Style AB10 • Suspended ceilings • Armstrong® TechZone'" .4 A , Item i Description fly i 1 4 6 1152 mmSquare Bar ` * . , 2 Patented 1-Bee2®Center Bracket I i 3 I End Bracket NOTE • FM/VdS/LPCB Approved,cUl_us listed. Style AB11 • Suspended ceilings • Hard-Lid ceilings ;`" Item Description [1, 1 I 24'7610 mm or 48(1219mm Square Bar ___. 2 t- Patented 1-Bee2'Center Bracket ',-- } End Bracket NOTE • FM/VdS Approved,cULus listed. T /iiLl Style AB12 • Suspended ceilings ® • • Hard-Lid ceilings L0:m Description fa , ,..�!-iiø' Strte AB12 Bracket Body___..< ,_ �� \-�.#2 are Drive Set Screw � • FM/VdS Approved. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. / _ victaulic.com • . 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA • Floor-above mount ,� • Cantilever mount • Temporary mount in exposed ceilings Item Description i 1 Style ABBA Mounting Plate ' Y 2 4,,,,_ rStyle ABBA Square Bar � 1_,,, i Cap Screw,Serated Flange,M6 x 1 x 20, i 'B 1 _T25 Torx Drive Recessed _ 4 Style ABMM Bracket Body_ 5 Cap Screw,Serated Flange,M6 x 1 x 15.24, ° y C i T25 Torx Drive Recessed ) Style ABMM • Surface mount � • Stand-off mount ,\, .• Item Description `1 a ilk„ ABMM Bracket Body _y �,.� I� 1 Style AB ,,,....0e, P� Flange, �.P Ca Screw,Serated M6 x 1 x 1 S 24, 2• T25 Torx Drive Recessed • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com • 4.4 DIMENSIONS - Clearances Series AH2 Braided Hose and Style AB1 Bracket . j I — RN BracKet See Chart i� l 1 Assemoly 2t /60 mm ."e/68 mm�b� Style AB1 41161/ max hole max hove I, _��1 ��� 51 mm 2fa/50mm d min hole min hole a: i•,/ 4.4"/ �. r�i 1 i.°mm 113 mm l - ii — lin -_ cciing e d _ 43 m " �� (IF' MIIr� Typical se n \ lR!"Ai ill%tio�'4% %!l. .I% !Al`�i�i l a'�a let Hnishec r 1 see note celi-ng face i lv LL24"/610 mm or 6 V27 V38 48"/1/19 mrn on Pendent C en.es Hose Clearance Chart Straight Reducer I Long Elbow Short Elbow I V2707 V3802 V2707 I V3802 1/2' 3/4' 1 1 ' V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess j Max Recess .3/4"Max Recess 1/2'Max Recess'3/4'Max Recess./Max Recess I - inches inches inches 1 inches inches inches inches inches mm mm mm i mm mm mm 1 mm mm j "R"Minimum 2.0 3.0 1 7.0 . Bend Radius 50 80 1 175 "A"Minimum I Required 8.6 1 10.1 1 9.6I 11.1 I 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space 1 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. . . .- I - victaulic.com • 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket it A .mm aril See c.hart Bracket 18"/ 5 crew _Style AB) �u�::... 4mrl /OSr>1 y/�yrnmaim /50r=gym c� zr lax hole max hole nax I1ole nam x.� == I Y...... i.. [r11-,I le __*I rnin�hole Stud N / �� rnr hole 3 5 • II Ulf Be rn 111 _ ///// . M1(-i !", !& f liF ////, % I-i�l�l'/��/// r \Fceil na J�S 1I 1 i ' 1 �dh. 1i 1%/ l__ Hose Clearance Chart Straight Reducer V2707 ' V3802 V2709 V2707 j V3802 V2709 V2707 V3802 V2709 3/a"120mm 1/2"113mm 3/4"120mm ' 3/4'120mm '/"113mm ', 3/4"120mm 3/4'120mm 1"113mm 3/4'120mm Max Recess" Max Recess i Sidewall Max Recess Max Recess Sidewall Max Recess : Max Recess Sidewall inches inches I inches inches inches inches inches I inches inches mm mm I mm mm mm I mm mm mm mm "R"Minimum { 2.0 3.0 i 7.0 Bend Radius _ 50 80 175 "A"Minimum t Required 6.2 7.6 I 6.1 7.2 8.6 7.1 11.2 I 12.6 11.1 Installation 158 193 155 183 218 ; 180 285 I 320 282 Space I Hose_Clearance Chart i Long Elbow Short Elbow V2707 V2709 V3802 3/a"I20mm WI20mm ' 1/2"113mm Max Recess Sidewall Max Recess inches i inches inches mm mm mm "Re Minimum Bend Radius "A"Minimum Required 3.3 3.6 I 3.3 ' ! Installation 84 91 I 84 j I Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. .. I - victaulic.cam • 4.6 DIMENSIONS • Clearances Series AH2 Braided Hose and Style AB4 Bracket A 2,8/6 "�e 0 tom 2 /68 mm i�i� See Chart max.hole max.hole ' _ - I 2/51 mm 2-'/60mm l I , min.hole min hole1 • III ill -, /'/159mm, rcal t1 apical fire h ^ �rs ceillne.tile ceiling nice 2y76r1a0mmoonC enter --'I See note rg mm Typical V27 V38 Pendent ceilir_eand Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4" le V2707 V3802 V2707 I V3802 Max Recess Max Recess ! Max Recess Max Recess 3/4"Max Recess lh"Max Recess 3/4"Max Recess '/i'Max Recess' • inches { inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R"Minimum 2.0 2.0 I 3.0 I. 3.0 7.0 1 7.0 • Bend Radius 50 50 80 80 175 175 s ; "A"Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 ! 8.0 5.9 Installation 224 259 249 285 ! 351 386 I 203 150 Space NOTE Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com . . 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket I # I, Will 2-37 ho f,„yoe Chao ;11-1.1.- Brdcket 1110:di A,semb,y 4 760,rm 296768 mot 2 ''/(59 9tre W.M Btyle AB5 .1 o i max max hole may hole I 1/, arum 2,/8"/60 mrn 2'61 mm „ lillM --' 1---* mo'•ole man nn'e noh hoe r 1 1 -.!iy 1 r o I o _il_ o I o iry;MM Metal Stal(1 '1'1 1 J MN '' j 1•4,1,MaJ e _. J iffaill ' '")1411611 '-#1rMilr, • V I 111410 IW— _Jo AN_ •24_I_!AI 2'2. J 4,,,....., I-4 1;0 / , 1 osneo ' IT li'lli I5q rem cer roo taco ..* 1O5'4,56 9 ee S;l1C.C Cs_ V27 V38 V27 Pendent Sidewall Hose Clearance Chart I Straight Reducer : "V2707 1 V3802 I V2709 V2707 V3802 V2709 V2707 V3802 V2709 1 3/4"I 20mm ' 1/2"I 13mm I 3/4"I 20mm 3/4"I 20mm I 1/2"I 13mm 3/4"I 20mm ' 3/4"I 20mm 1/2"I 13mm 3/4"I 20mm 1 Max Recess Max Recess I Sidewall Max Recess I Max Recess , Sidewall Max Recess Max Recess Sidewall 1 inches inches inches inches inches i inches inches inches inches mm mm mm mm mm , mm mm mm . mm I ""R Minimum 2.0 3.0 , 7.0 . . [ Bend Radius 50 80 I 175 : 1 I 1 1 I "A"Minimum . . . . Required 6.0 7.7 6.1 7.0 8.7 7.1 ' 11.0 12.7 , 11.1 Installation 158 196 155 178 , 221 1 180 279 i 323 282 I Space I I ..._ Hose Clearance Chart 1 r , 1 ' 1 1 Low-Profile Long Elbow I Long Elbow . Short Elbow T-- 1 V2707 , V3802 V2709 V3802 ' V3802 Yr"I 20mm 1 1/2"I 13mm 3/4"I 20mm 1/2"I 13mm 1/2"I 13mm Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm 1 mm mm : mm I mm i t ' ""R Minimum Bend Radius I "A"Minimum I ; Required . 3.5 : 4.9 3.6 I 2.9 3.3 i 1 1 124 . 91 1 74 84 Installation ' 89 Space - NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. . . .. / _ victaulic.com • •4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 2N"/60 mm 216.E/68 mm A Bracket max.hole max.hole Assembly 2"/51 mm 27/60 mm A q_p Style AB11 min.hole min.hole 14- See Chart 0a 3.0"/ I 111 ■0 11 I I ' 76 mm '�_ ♦ 11 ff R. Kira*41 1.7'743 mm h.d Firnshed i$I iyp •ical f '/s/15.9 mm ceiling face ceiling grid Typical ceiling tile See Note — 24/610 mm or V27 V38 4871219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 3/4"I20mm 1/2"I13mm Max Recess"I Max Recess inches 1 inches mm mm [ "A"Minimum Required 4.0 3.9 Installation 102_ f 99 • Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com • • 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Recessed Sprinkler and Low Profile Short Elbow Straight 5.75"/140mm Reducer - - ,� � i g1.,e 4 /17/ f I:i,f 111 \nl h Ell /pink __ .___.__.� / .. 1 S AM wiT T re bar 1r7f �J y �miIY� ri l�..> 7 Bch' _ }• _ E _ 1 abl SE.313 1 _ _ 'r'lr}IF i IMINI 1 ;I�It> 11 ., u . '-1 I di �� * V2707'5/12.7 mm MAX.RECESS V2707'A"/19 mm MAX.RECESS 1 Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer i3/4719mm 3/a'%19mm 34719mm; 3/4'/19mml 3/4719mm Recessed* Concealed Recessed Concealed Recessed 1:Concealed Recessed ?Concealed Recessed 'Concealed inches inches inches ! inches inches inches inches inches inches inches mm mm mm I mm i mm mm I mm mm mm mm r I i I I I A a Minimum Required 4.0 5,5 5.6 7.2 1 5.9 7.5 j 7.7 9.3 15.0 16.6 Installation Space : 101.6 E 139,7 142.2 3 182,9 I 149.9 190.5 195.6 € 236.2 381.0 421.6 I Distance from Top of; 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 i 76.2 76.2 76.2 Bottom of Gate *Adjustability will be limited Style ABMM Bracket Stand-off Dimensions -222/ i56 nxn I p= '-_ pl „ �+li->_p b 3.93"/ 2__47 75 mm 100 rnrn0 `lo 1 ie) 0 j n0100 mm 7 28rnr/ 11 !. n f _. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. . . .. / - victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler A /___-_- R C i ■. IIIIIMIIIIII G-aa E-_, _= 953/mm .,,,, r _.±_,.... ,...„. , ,,,..„f LLJ A mm 4111111110 4110#1„ 23/s"/60 mm max.hole 2"/51 mm min.hole Hose Clearances inches inches I inches :inches inches inches 1 inches inches ?inches inches Dimension mm mm mm mm mm mm 1 mm mm ! mm i mm I Wall Thickness 2 4 i 6 8 10 2 j 4 6 8 ' 10 A 50 100 150 ' 200 250 50 ' 100 150 200 250 - i Outlet Length�5.75 9; e 13 �5.75 9, 13 1 9 T 13 13 13 5.75 9 13 s 5.75 9 3 13 9 ` 13 13 13 T r "8 1146.1 228.E 330 2:1461 228.6 330 21228 6 330.21 1 3302 3 330.2 1461 228.6 330.211461 22$6 330.2 228 61330 21 330.2 330.2 IHoseClearance` 11.6 14.8 18.8 9.6 12.8 16.8 i 10.8 14.8 ' 12.8 10.8 12.6 i 15.8 19.8 10.6 13.8 . 17.8 11.8 15.8 i 13.8 11.8 . "C' 294 376 I 478 243 325 427 ? 275 376 325 275 319 ` 402 503 € 268 351 452 300 402 i 351 300 I. Bend Radius i 7 8 1 "R" i_ 175 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. / _ victaulic.com • 5.0 PERFORMANCE — FRICTION LOSS DATA p c �L us Series AH2 and AH2-CC Braided Hoses with Straight 5.75"/140 mm Reducers LISTED Style AB1, AB2, AB4, AB5 and AB10 Brackets Maximum Equivalent Length Number of of 1"/33.7 mm 90°Bends at 2'751 mm Sch.40 Pipe(C=120) Bend Radius inches/mm inches/mm/type feet/meters 31/790 1/2715/Straight 16/4.9 4 3/a 720/Strai ht 17/5.2 36/915 1/z'"/15/Stra ht 21/6.4 5 /a/20/Strai ht 23/7.0 - 5 3 (} 1/z"/15/Straight I 32/9.8 f 8 , 48/1220 3/a"/20/Strai ht i 37/11.3 i 8 60/1525 1/2'/15/Straight 46/14.0 _ 10 3/4/20/Straiight 46/14.0 10 __ ._ h"/15/Straight 55/16.8 _� _ __— 12 1 72/1830 3/a/20/Strai ht 1 53/16.2 12 US Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows CC LISTED Style AB11 VicFlex Bracket Maximum i Equivalent Length Number of of 1"/33.7 mm 90°Bends at 2'751 mm • Sch.40 Pipe Bend Radius 1 inches/mm inches/mm feet/meters W 31/790 /15 24/7.3 , w _ 4 1. /a l20 24/7.3 4 36/915 1/2"/15 26/7.9 5 3/4/20 1. 28/8.5 5 . ' /15 i 43/13,1 8 4$/1220 3/4/20 42/12.8 $ 1/ /15 ; 49/14.9 10 60/1525 — - -- --- __ 3/a"/20 50/15.2 10 1 72/1830 i 1h"/15 65/19.8 12 ., 0 � ...r- ya720i 63/19.2 12 • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com • 5.0 PERFORMANCE — FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2"/51 mm center line bend radius ;Length of Stainless Steel Flexible Outlet ! 1 2 3 4 5 6 7 8 9 10 11 12 Hose Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches/ inches/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ mm mm meters I meters I meters meters I meters j meters meters meters meters meters meters meters Yz/15 8 5/2 6 1 11.0/3.4 113 0/4 0 11b 0/49 N.A N.A N.A N.A 14.A N.A N.A NA 31/790 3/4/20 10.0/3.0 12 5/3,8 14 0/4 3 :+ 17 0/5 2 _ NA N.A N.A N.A N.A NA N.A N.A 36/915 1/22/15 13.5/4 14 16 0/4.9 L 18 0/5 5 19 0/5 8 j 21.0/6.4 I N.A N.A N.A N.A N.A N.A N.A 3/4/20 —14.0/4 3 17 0/5 2 I 19 5/5 9 20 0/6.1 23.0/7.0 I N.A N.A N.A N.A N.A N.A N.A Y2"/15 15,5/4.7 17 0/S 24 19 5/5 9 . 20 0/6.1 1 21.0/6.4 II 22.9/6.7 128.0/8 5 ' 32.0/9.8 1 N.A r N.A N.A� N.A 48/1220 120 17.0/5.2 19.0/5.8 21.5/6.6 24 5/7 5 4_26.0/7.9_1 27.0/8 2 1300/91 37,0/11 3 _ N A N.A N.A I N.A 60/1525 4//15 21.5/6 6 7 24 0/7.3 127 0/8 2 28 5/8.7 30 0/9.1 31 0/9 4 i 37 0/11 3 42 0/12 8 a 44 0/13 4:46 0/14 t N A N.A 3 /20 23.0/7 0 24 0/7 3 1 28 0/8 5 29.5/9.0 30 5/9.3 31.0/9 4 38.0/11 64,42.0/12.8 j 44 0/13 4 460/140 N.A N.A 1 72/1830 'lz"/15 7 30.0/91 F 32 0/9 8`36 5/11 1 37.5/11.4 40.5/12 5141.0/12.8 42.0/12.8 46 0/14.0'49.0/14.9 52 0/15.8154.0/16 5 t 55.0/16 8 E Ufa"/20 32.0/9.8 3 32 5/9 9 35 0/10 7-35 5/10 8140 0/12 3 40 5/12 3 41.0/12 5146 0/14 0 50 0/15 2 L 51.0/15.5 52 0/15 8 53.0/16.2 NOTES: • Values for use with 5.757140mm straight reducers. How to use this Design Guide: • For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be • recalculated using actual equivalent lengths to verify the performance of the system. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company All rights reserved. victaulic.com • • 5.1 PERFORMANCE — FRICTION LOSS DATA y ® Series AH2 and AH2-CC Braided Hoses Style AB1, AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of I Length of of 90°Bends I.' Stainless Steel Outlet 1"/33.7mm at 7"/178mm Flexible Hose K-Factor Size Sch.40 PipeI. Bend Radius f inches/mm j Imperial/S.I. inches/mm/type j feet/meters 31/790 5.6/8.1 '! 11 S/Straight 13 8/4 2 2 I F ?!x! 5/90°Elbow 23 S/d 1 36/915 5.6/8.1 ' "/15/Straight 16.6/5.1 /z2 Y /15/90°Elbow 25.6/7 8 i 1715/Straight �_ 23.4/7.1 48/1220 5.6/8.1 t3 f15/94 Elbow E 34 7/9 3 60/1525 5.6/8 1 /z/15/Straight 30 2/9 2 1/ /15/90 Elbow 35 9/10 9 4�_ _ — '/z"f1S/Strai htf 370/113 4 72/1830 5.6/8.1 g m . '/"/15/90 Elbow I 41.1/12.5 ; 3/4"/20/Strai ht 16.8/5.1 31/790 8.0/11.5 _ ! 2 3/4/20/90'Elbow _ 16.8/5.1 I I. 20/Straight 20/6.0 36/915 , 8.0/11.5 — 3/a"/ 2 _. _ .� 3/4/20/90°Elbow i 197/6.0 ,. 3/4"/20/Strai ht 27.8/8.4 48/1220 8.0/11.5 — — 3/a/20/90"Elbow 26 6/8 1 3 ' 34/20/Straight I 35 7/10 9 64f1525 8.0/11.5 3/al24f90 Elbow 1 336/102 4 1 /a/20/Strai ht 43.5/13 2 3 72/1830 8.0/11.5 g -- " 3/a'/20/90'Elbow 40.6/12.2 4 3/a°/20f5traf ht 16.Sf5.0 31/790 I. 11.2/161 I--- — i 2 3/4/20190 Elbow 17 8/5 4 36/915 11.2/16.1 3/a'"/20/Straight 19 5/5 9 3/a"/20/90°Elbow 20.7/6.3 2 4.8/1220 112/16.1 ,--._ g I 26.7/8,1 3 I 14/20/90°Elbow 60/1525 11.2/16.1 a. / 0 279/10. /a/20/Straight 33.9/10.3 3 3 /20/90°Elbow 35/10.7 4 72/1830 i 112/t61 3 /20/Straight 413/125 3/4/20/90° 4 Elbow i 42 2/12 8 3/4/20/Straight 14.9/4.5 31/790 14.0/20.2 - 2 3/a/20/90 Elbow 15.5/4.72 � �� ! 31a"/20fstrai ht 19.4/5.9 � 36/915 140/20.2 I g2 r 3{/20/90 Elbow 19 6/5.9 48/1220 I 14 0/202 ;-.- 3/a/20/Straight 30.3/9.2 3 3 /20/90°Elbow 29 5/8 9 3/a"/201Straight 33.911Q.3 60/1525 14.0/20.2 i" 4 �' _ /a/20/90°Elbow 1 34.1/10.4 3/a/20/Strht 37 5/11 4 72/1830 14.0/20.2 - — —- 3/a"/20/90°Elbow 38.6/11.7 4 FM NOTES: � • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13, 13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance, leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30"bends arid two 90"bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees Is 240°,which Is less than the allowable 270°. • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Vlcteulic Company.All rights reserved. . . .. I - victaulic.com 5.2 PERFORMANCE — FRICTION LOSS DATA _ t ® Series AH2 Braided Hose with 90° Low Profile Elbows _ Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent I Number Length of Length of 1 of 90°Bends Stainless Steel I Outlet 1"/33.7mm at 7"/178mm Flexible Hose i K-Factor Size Sch.40 Pipe Bend Radius I inches/mm Imperial/S.I. ' inches/mm ; feet/meters 31/790 5.6/8.1 1/20/15 13.7/4.2 I 2 36/915 5.6/8.1 1/2"/15 17.0/5.2 2 E 48/1220 i 5.6/8.1 I/2/15 25 0/7 6 I 3V 60/1525 j 5.6/8.1 1/2"/15 33.0/10.1 4 72/1830 I 5.6/8.1 'h"/15 I 41.1/12.5 i 4 31/790 8.0/11.5 3/a"/20 13.6/4.14 2 36/915 ; 8.0/11,5 3/40f20 16.9/5.2 1 2 1 48/1220 8.0/11.5 3/a/20 27.8/8.5 3 i 60/1525 8.0/11.5 1 3/4'720 32.6/9.9 I 4 72/1830 8.0/11.5 3/4"/20 40.6/12.4 4 '. 31/790 11.2/16.1 3/4"/20 1 � 13.7/4.2 1 2 t 36/915 11.2/16.1 3/4"/20 17.0/5.2 2 a i 48/1220 11.2/16.1 3/a/20 1 249/76 i 3 ! 60/1525 11.2/16.1 3/4720 j 32.9/10.0 4 i 72/1830 11.2/16.1 1 3/a"/20 j 40.9/12.5 I 4 I 31/790 j 14.0/20.2 3/a"/20 13.5/4.1 2 1 36/9t5 14.0/20.2 31�"/20 16.8/5.t�_� 1 2 48/1220 I 14.0/20.2 i 3/4"/20 24.7/7.5 3 t---- ' 60/1525 14.0/20.2 [ W/20 ! 32.7/9.9 4 E 72/1830 14.0/20.2 3/a"/20 40.7/12.4 4 1 FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13, 13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow charactensitics,vibration resistance, leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends arid two 90°bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which Is less than the allowable 270°. 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. I - victaulic.com • • 5.3 PERFORMANCE — FRICTION LOSS DATA VdS Series AH2 and AH2-CC Braided Hose . Style AB1, AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Y Equivalent Length of Maximum Number Length of 1 steel pipe according to of 90°Bends at Stainless Steel Outlet EN 10255 DN 25 3"/76.2 mm Bend Flexible Hose Size (33,7 x 3,25) Radius 1 mm/inches mm/inches i meters/feet meters/feet 31/790 { l5mrnt'h, 1 5 5/18.0 3 20mrr /4 _� 15 mm//z' 36/915 „ 1 6.4/21.0 3 3 20mm//a 48/1220 1 15 mm 3/2' 8.5/27.9 3 I. 20mm/fa 15mm/'/z 60/1525 10.7/35.1 4 ! 20 m m//4 3 ' 15 mm/1/z" s 72/1830 t-- 12.8/42.0 ', 4 L.._ _ 20mm/1/a' VDS CEILING MANUFACTURERS LIST AB1,AB2,AB7,AB10,AB11 AB4 AB5,AB8 1.AMF No specific approval 1. Hilti 2.Armstrong 2 Knauf 3 Chicago Metallic 3.Lafarge 4.Dipling 4 Lindner 5 Durlum 5.Rigips 6.Geipel 7.Gema-Armstrong . 8.Flit 9.Knauf 10. Lafarge 11.Linder 12.Odenwald 13. Richter 14.Rigips 15. Rockfon Pagos 16.Suckow&Fischer 17.USG Donn Series AH2 and AH2-CC Braided Hose Series AH2 Braided Hose ILPCBJ Style AB1, AB2, AB3, AB4, AB5, AB7, AB8, ® Style AB1, AB2, AB3, AB4, AB5, AB7, AB8, and AB10 Brackets AB10 and AB12 Brackets Length of ! Equivalent Length !! Maximum Stainless ! I of steel pipe Number of Steel ! according to '90°Bends at Length of Flexible Outlet I EN 10255 DN 25 3"/76.2 mm Flexible Equivalent Length of Hose ! Size (33,7 x 3,25) 'Bend Radius Hose 1"/33.7mm Sch.40 Pipe ' mm mm/inches mm/inches/type , meters/feet i inches Straight Configuration Bend Configuration 790/31 :-15 mm/'k"/Straight I r 790 0.87 1 2.70 i ' 20mm/W/a'/Straight 1.8/6.0 2 31 2.9 8,9 15 mm/Yz'/Straight 1 915 1.00 2.80 915/36 '— 3.6/11.9 3 36 3.3 'i 9.2 _ _20mm/3/a/Straight 1220/48 15 mmh/2-/Straight �� 1 .7 1220 2.23 4.66 20mml3f"/Straight 4.3/14.0 3 I _w ` 7•3 f t5 3 = 1 15 mm/1/"/Strai ht i 9 1525 � 2.90� �€ 6.5 1525/60 - - 4.1/13.6 3 60 9.5 21.3 20mm/3/4'/Straight 15rnm/'/i"/Straight: i _ �_ 1830 3.31 7.16 1830/72 §5/18.1 i 3 r 20mm/3 0/Straight i 72 10.9 i 23.5 CCCF NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute(30 gallons per minute). • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 6.0 NOTIFICATIONS 0 00, `� • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installa- tion, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • .~It isthe responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com • • 7.0 REFERENCE MATERIALS -CHARACTERISTICS 1 VicFlex Maximum Load Values • Series AH2 Hose with 24" Bracket , Actual Length Total Load 1 Max. Uniform Load I ft Model Size I m lb N Ib/linearft N/linearm i 31/790 € 0.8 52 I. 23 2.6 38 36/915 p 9 I 5.5 25 2.8 40 48/1220 1.2 1 6.3 28 I 3.1 3 46 60/1525 I 7.0 31 3.5 51 1.5 72/1830 , l 7.7 34 j 3.9 57 1 t.8 I Series AH2 Hose with 48" Bracket Actual Length Total Load Max.Uniform Load Model Size m lb N ! lb/linear ft N/linear m 31/790 j 0.8 F 6,1 27 1 1.5 1 22 1 36/915 i 0.9 6.4 29 1.6 23 48/1220 7.2 rn 4 32 1.8 1 26 I 1.2 ^ I 60/1525 7.9 35 2.0 29 1.572/1830 6 8.7 i I 1.8 1 39 2.2 32 i I Total Load is defined as the sum of the weights of the following: • water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Min.Allowable Uniform Load Suspension System ft/m lb/linear ft j N/linear m Light I 5.0 I 75.7 17irectHung Intermediate 12.0� I 181.0 w,_ Heavy 16A .__ f 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. • • • 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 7.0 REFERENCE MATERIALS — CHARACTERISTICS (CONTINUED) t Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends (7:- (7(------ x 2x I „i I �m rf G!1'Jrr - her ad,. t),nd radius 'I oend,aJlus OR Minimum_ OR bend radius 90° I \ X n rllrs \ -- d radars NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. v BI. sI ' Is a e39/312 I_Y iiulS x A 7 1-VicirekA1312 I-VIcFIex-ABBA • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for mak ng a determination as to the suitability of f h.s product shall be menu`act ired by V ctaiilw or to Victarilic specifications.All_roducto Victaulic products for a particular end use application,in accordance with industry to be installed in accordance with current Victaulic Installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs ar-d standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. Instructions Nothing In this or any other document,nor any verbal recommendation. Installation advice,or opinion from any Victaulic employee,shall be deemed to alter vary,supersede, Reference should always be made to I-VICFLEX-AB1-AB2AB10,I-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale,installaton I-VICFLEX-AB7,or I-VICFLEX-AB8 for the product you are installing.Handbooks are guide,or this disclaimer- Included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website at www.vietaultc corn. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details, s under any patent or other Intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use e design, asof a re nren naatlon for the use r i such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Vic1a06c and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or'Patent Pending"refer to design or utility patents Victaulic Company,and/or Its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use In the United States and/or other • countries. 10.85 5839 Rev AG Updated 07/2019 ©2019 Victaulic Company.All rights reserved. I - VERTICAL MOUNT 4 '' SAMMYS® for Wood Not less than Wood Flooring Product Features 2°nominal width (1-1/2°) 1-1 •No pre-drilling required. r , Not less than t •Quick to install using the Sammy knominal Nut Driver with an 18V cordless thickness(2-1/2") (depth or side Wood Joist drill/driver. itof verhcal member) i • •Saves time from traditional Double Sheetrock methods. • For vertical use- Ceiling install in center of lower face. •Reduces installation cost. Minimum 2"embedment into base .. ° material for NFPA 13 compliance, Composite 1 Truss •Made in the U.S.A. Consult truss manufacturer for recommended installation point *Predr/ling maybe recryired for GST '> 25-380.Tool available on page 10il it Approvals Rod Part Model Screw Ultimate ULTest FM Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Qty Qty — 1/4" 8002957 GST 100 1/4x 1" 210(7/16"t7St3) 25 125 570(3/4'Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 ` GST 300 1/4 x 3" 2060(Fir) 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 3/8" 8007957 : GST 10 1/4 x 1' 210(7/16"OSB) 300 25 126 670(3/4 Ply) _ `Q"0 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 / 3/8" 8068925 GST 24SS 1/4 x 2" 1760(Fir) 850 25 125 i 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4x3" 2060(Fir) 1500 1475 25 125 Nut Black Nut Driver 3/8" 8069925 GST 30-SS 114 x 3" 2060 (Fir) 25 125 Part#8113910 318" 8011925 GST 40 1/4 x 4" 2180(Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 _ 1/2" 8013925 GST 2 1/4 x 2" 1760(Fir) 25 125 — 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8016925 GST 3 1/4 x 3" 2275(Fir) 25 125 — 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230(Fir) 25 125 #14 Nut DriverSWRed Part#8114910 SAMMY Swivel Head® for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3'/2"x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. . Rod Part Screw Ultimate UL Test FM Test Min Box Case ... Approvals Model Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thickness Qty Qty 4^j 3/8" 8139957 SN-GST 20 1/4x 2" 1257(Fir) 1050 1475 25 126 125 a Q.:0 3/8" 8141957 SH-GST 30 114 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. Pi For the most up to date information,visit www.sammysuperscrew.com 4 iiiii"--- Hs 4