HomeMy WebLinkAboutSpecifications (3) rPs Z623-
WYAT T
FIRE PROTECTION, INC.
'414,1rW'
9095 S.W. Burnham
Tigard, OR 9722EEr EIVFn
l'-i!AY 4 2K3
CITY'OF TICITO
BUILDING DIVLIC,r%!
SANDHU RESIDENCE
12758 SW WILLOW POINT LANE
TIGARD, OR 97224
4
FIRE PROTECTION
EQUIPMENT SUBMITTAL
ti,ca
Worldwide www.tyco-fire.com
Contacts
RAPID RESPONSE Series LFII Residential
4.9 K-factor Concealed Pendent Sprinkler
Flat Plate, Wet Pipe System
IMPORTANT The cover plate assembly conceals
the sprinkler operating components `
Refer to Technical Data Sheet above the ceiling.The flat profile of the
TFP2300 for warnings pertaining to cover plate provides the optimum aes-
regulatory and health information. thetically appealing sprinkler design. >~ .,_
Always refer to Technical Data In addition, the concealed design of u,
Sheet TFP700 for the "INSTALLER the Series LFII Residential Concealed
WARNING" that provides cautions Pendent Sprinklers provides 3/4" (19,1
with respect to handling and instal- mm) vertical adjustment. This adjust-
lation of sprinkler systems and com- ment provides a measure of flexibility ,
ponents. Improper handling and when cutting fixed sprinkler drops.
installation can permanently damage The Series LFII Residential Concealed
a sprinkler system or its compo- Pendent Sprinklers are intended for use
nents and cause the sprinkler to fail in the following scenarios:
to operate in a fire situation or cause
it to operate prematurely. • Wet pipe residential sprinkler sys-
tems for one and two family dwell-
ings and mobile homes per NFPA 4° ..
Scan the QR code or enter the URL 13D
in a web browser to access the most •up-to-date electronic version of this Wet pipe residential sprinkler sys-
document. Data rates ma apply. terns for residential occupancies up
yto and including four stories in height
❑ ,r ) ❑ per NFPA 13R
F - . ii. • Wet pipe sprinkler systems for the NOTICE
■ - residential portions of any occu- The Series LFII Residential Concealed
Aritirit T`l v. panty per NFPA 13 Pendent Sprinklers(TY2534)described
T•r 1 OFF The Series LFII Residential Concealed herein must be installed and main-
. 7 Pendent Sprinklers have been designed tained in compliance with this docu-
'� with heat sensitivity and water distri- ment and with the applicable standards
•• �• bution characteristics proven to help of the NATIONAL FIRE PROTECTION
I in the control of residential fires and to ASSOCIATION (NFPA), in addition to
■■
improve the chance for occupants to the standards of any authorities having
Elri �� .� escape or be evacuated. jurisdiction.Failure to do so may impair
• The Series LFII Residential Con- the performance of these devices.
docs.jci.com/tycofire/ cealed Pendent Sprinklers (TY2534) The owner is responsible for main-
rapid-response-4_9k are shipped with a Disposable Protec- taining their fire protection system
tive Cap. The Protective Cap is tem- and devices in proper operating con-
porarily removed for installation, and dition. Contact the installing contrac-
General then it can be replaced to help protect tor or product manufacturer with any
the sprinkler while the ceiling is being questions. i
Description installed or finished.The tip of the Pro-
tective Cap can also be used to mark Sprinkler
The TYCO RAPID RESPONSE Series the center of the ceiling hole into the
LFII Residential 4.9K Concealed plaster board, ceiling tiles, and so on, Identification
Pendent Sprinklers(TY2534) are dec- by gently pushing the ceiling product
orative, glass bulb sprinklers, avail- against the Protective Cap. When the Number (SIN)
able in both ordinary 155°F(68°C)and ceiling installation is complete the Pro-
intermediate 200°F (93°C) tempera- tective Cap is removed and the Cover TY2534
ture rated configurations. They are Plate Assembly is installed.
designed for use in residential occu-
pancies such as homes, apartments,
dormitories, and hotels.
Page 1 of 6 NOVEMBER 2021 TFP446
TFP446
Page 2 of 6
Technical SUPPORT FRAME
CUP WITH (1/2"NPT)
Data ROLL FORMED
- THREADS
Approvals SPRINKLER
""UL and C-UL Listed "" "" """�������' WRENCH
The TYCO RAPID RESPONSE Series LFII SEALING _I\ FLATS
Residential Concealed Pendent Sprinklers ASSEMBLY r
are Listed only when installed with LFII Con-
cealed Cover Plates having factory-applied BUTTON
finishes.
Sprinklers and Cover Plates are separately GUIDE
ordered. See the Ordering Procedure PIN
�, section for more information. BULB
Maximum Working Pressure
Hi__ 1) Li
175 psi(12,1 bar) BRIDGE ) 1
BRIDGE
Discharge Coefficient EJECTION
K=4.9 GPM/psi' (70,6 LPM/bar'') SPRING
COMPRESSION
Temperature Rating SCREW
Ordinary DEFLECTOR
155°F(68°C)Sprinkler (OPERATED
139°F(59°C)Cover Plate DEFLECTOR POSITION)
Note:Maximum Ambient Ceiling Tempera- LJ-r `1_ I
ture for the ordinary temperature configura-
tion is 100°F(38°C). SPRINKLER
Intermediate ASSEMBLY
200°F(93°C)Sprinkler THREAD INTO j RETAINER
165°F(74°C)Cover Plate SUPPORT WITH THREAD
Note:Maximum Ambient Ceiling Tempera- CUP UNTIL , DIMPLES
ture for the intermediate temperature con- MOUNTING i,
,
figuration is 150°F(65°C). SURFACE IS ) A �� i
FLUSH WITH
Vertical Adjustment CEILING EJECTION
3/4 in.(19,1 mm) SPRING
Finishes J
See the Ordering Procedure section �1 or��
Physical Characteristics SOLDER COVER PLATE COVER
Frame Brass
Support Cup Plated Steel TAB ASSEMBLY PLATE
Guide Pins Stainless Steel FIGURE 1
Deflector Bronze RAPID RESPONSE SERIES LFII RESIDENTIAL
Compression Screw Brass
Bulb Glass CONCEALED PENDENT SPRINKLER(TY2534)
Button Phosphor Bronze
Sealing Assembly..Beryllium Nickel w/TEFLON
Cover Plate Brass
Retainer Plated Steel
Cover Plate Ejection Spring.... Stainless Steel
Bridge Bronze
Bridge Ejection Spring INCONEL
4
Operation
When exposed to heat from a fire, the
Cover Plate, normally soldered to the
Retainer at three points, falls away to
expose the Sprinkler/Support Cup
Assembly.
The Deflector,supported by the Guide
Pins, then drops down to its operated
position.
The glass bulb contains a fluid that
expands when exposed to heat.When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb,activating the sprinkler and
allowing water to flow.
TFP446
Page 3 of 6
WET PIPE SYSTEM
Minimum Flow and Residual Pressure2'3
Maximum Maximum
CTemp.Rating -
A Area 9e Spacing 155°F(68°C),200°F(93°C) Minimum
ft x ft ft Deflector to Installation Spacing
(m x m) (m) Flow Pressure Ceiling Type ft
GPM psi (m)
(LPM) (bar)
12 x 12 12 13 7.0
(3,7 x 3,7) (3,7) (49,2) (0,48) Smooth
Ceilings
14 x 14 14 13 7.0 3/8 to 1 1/8 in.
(4,3 x 4,3) (4,3) (49,2) (0,48)
Beamed i
16 x 16 16 13 7.0 Ceilings per 8
(4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2,4)
13R,or 13.
Installed in
18 x 18 18 17 12.0 beam
(5,5 x 5,5) (5,5) (64,3) (0,83) 3/8 to 1 1/8 in.
below bottom
20 x 20 20 20 16.7 of beam
(6,1 x 6,1) (6,1) (75,7) (1,15)
Notes:
1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage
area for which hydraulic design criteria are stated.
2. Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated
using the nominal K-factor.See Hydraulic Design under the Design Criteria section.
3. For NFPA 13 residential applications,the greater of 0.1 GPM/ft°over the design area or the flow in accordance with the criteria in
this table must be used.
TABLE A
WET PIPE SYSTEM
SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER(TY2534)
NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA
Design Criteria specified in NFPA 13D or NFPA 13R. Operational Sensitivity
The sprinklers are to be installed rela-
Hydraulic Design tive to the ceiling mounting surface as
The TYCO RAPID RESPONSE Series (NFPA 13)
LFII Residential Concealed Pendent For systems designed to NFPA 13,the shown in Figure 2.
Sprinklers (TY2534) are UL and C-UL number of design sprinklers is to be Sprinkler Spacing
Listed for installation in accordance the four most hydraulically demanding The minimum spacing between sprin-
with this section. sprinklers.The minimum required dis- klers is 8 ft (2,4 m). The maximum
Note: When conditions exist that are charge from each of the four sprinklers spacing between sprinklers cannot
outside the scope of the provided cri- is to be the greater of the following: exceed the length of the coverage area
calcu-
teria, refer to the Residential Sprinkler . The flow rates given in Table A as a (see Table xA bpi e,ng hydraulically fora
Design Guide TFP490 for the manu- function of temperature rating and fated,for example,maximuma 12 ft for a
facturer's recommendations that may the maximum allowable coverage 12 20ft x 12 20f coverage area, .o 20 ft for
be acceptable to the authority having area a ft x ft coverage area.
jurisdiction. The Series LFII must not be used
• A minimum discharge of 0.1 GPM/ft2
res-
Ceiling Types over the design area comprised of inapplications above
wheregthe air than
Smooth flat horizontal, beamed, or the four most hydraulically demand- sure bbove the ceiling is greaterthrough than
sloped in accordance with NFPA 13D, ing sprinklers for actual coverage that below. Down drafts yp the
13R,or 13 as applicable. areas protected by the four sprinklers Supportpo inC ap could delay sprinkler
operation in a fire situation.
Hydraulic Design Obstruction to `
(NFPA 13D and 13R) Water Distribution
For systems designed to NFPA 13D or Sprinklers are to be located in accor-
NFPA 13R,the minimum required sprin- dance with the obstruction rules of ,
kler flow rates are given in Table A as a NFPA 13D, 13R, and 13 as applicable
function of temperature rating and the for residential sprinklers as well as with
maximum allowable coverage areas. the obstruction criteria described within
The sprinkler flow rate is the minimum the Technical Data Sheet TFP490.
required discharge from each of the
total number of"design sprinklers" as
TFP446
Page 4 of 6
2-1/2"DIA. SPRINKLER-
(63,5 mm)1 3/4"(19,1 mm) FACE OF SUPPORT CUP
THREADED SPRINKLER ASSEMBLY
ADJUSTMENT FITTING
/ OPERATED
� SPRINKLER ��
-
_r_Li.,,i
21/8"±3/8 N' COVER
(54,0 mm PLATE ElF
3/32"GAP ±g 5 mm)" .111 n . Ii7 %' RETAINER(2,4 mm) ii
:Ig
19/16"(14,3 mm)
COVER- SPRINKLER t‘ i-
MOUNTING REPLACE AFTER � 5/16"(33,3 mm)
RETAINER SUPPORT CUP 5/32" SURFACE / INSTALLATION-_
ASSEMBLY ASSEMBLY (4,0 mm) il_Ill
3-1/4"DIA. n DISPOSABLE lir DEFLECTOR IN
(82,6 mm) V..- PROTECTIVE CAP TIP OPERATED POSITION
FIGURE 2
RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY2534)
INSTALLATION DIMENSIONS,PROTECTIVE CAP,AND ACTIVATED DEFLECTOR
Installation Note: Do not engage the sprinkler H
frame arms by the wrench,engage only RECESS WRENC
The TYCO RAPID RESPONSE Series the sprinkler wrench flats. \
LFII Residential Concealed Pendent Step 4. Replace the Protective Cap by ' liii
Sprinklers (TY2534) must be installed pushing it upwards until it bottoms out _
in accordance with this section. against the Support Cup. The Protec-
tive Cap helps prevent damage to the O 1
General Instructions Deflector and Guide Pins during ceil- 0
Do not install any bulb-type sprinkler ing installation and/or during applica
if the bulb is cracked or there is a loss tion of the finish coating of the ceiling. 1/2"SQUARE
• of liquid from the bulb, With the sprin- It may also be used to locate the center DRIVE SOCKET U
kler held horizontally,a small air bubble of the clearance hole bygentlypushing
should be present. p g FIGURE 3
the ceiling material against the center W-TYPE 42
A 1/2 in. NPT sprinkler joint should be point of the Cap. SPRINKLER WRENCH
obtained with a minimum to maximum Note: As long as the protective Cap
torque of 7 to 14 lb-ft(9,5 to 19,0 the N remains in place,the system is consid-
Higher levels of torque may distort the ered to be"Out Of Service."
sprinkler inlet with consequent leakage
or impairment of the sprinkler. Step 5. After the ceiling has been
Do not attempt to compensate for completed with the 2 1/2 in. (63 mm)
insufficient adjustment in the Cover diameter clearance hole and in prep
Plate Assembly by under-or over- aration for installing the Cover Plate
tightening the Sprinkler. Readjust the Assembly,remove and discard the Pro-
position of the sprinkler fitting to suit. tective Cap,and verify that the Deflec
tor moves up and down freely.
Step 1. The sprinkler must only be If the sprinkler has been damaged and
installed in the pendent position and the Deflector does not move up and
with the centerline of the sprinkler per down freely,replace the entire sprinkler
` pendicular to the mounting surface. assembly. Do not attempt to modify or
Step 2. Remove the Protective Cap. repair a damaged sprinkler.
Step 3. With pipe thread sealant Step 6. Push on the Cover Plate
- applied to the pipe threads and using Assembly until its flange comes in con-
the W-Type 42 Wrench shown in Figure tact with the ceiling.
3, position the wrench recess to first Do not continue to push on the Cover
straddle the deflector guide pins from Plate Assembly such that it lifts a
the side and then push the wrench into ceiling panel out of its normal position.
the support cup to engage the sprin-
kler wrench flats. Rotate clockwise If the Cover Plate Assembly cannot
to tighten the Sprinkler/Support Cup be engaged with the Mounting Cup
Assembly into the fitting. The W-Type or the Cover Plate Assembly cannot
42 Wrench will accept a 1/2 in. ratchet be engaged sufficiently to contact the
- drive. ceiling, the Sprinkler Fitting must be
repositioned.
TFP446
Page 5 of 6
Care and Do not pull the Cover Plate relative to Limited
the Enclosure.Separation may result.
Maintenance Sprinklers which are found to be Warranty
leaking or exhibiting visible signs of -
The TYCO RAPID RESPONSE Series corrosion must be replaced. For warranty terms and conditions,visit
LFII Residential Concealed Pendent www.tyco-fire.com.
Sprinklers (TY2534) must be main- Automatic sprinklers must never be
tamed and serviced in accordance with painted, plated, coated, or otherwise Ordering
this section. altered after leaving the factory. Modi-
fied or over heated sprinklers must be
Before closing a fire protection system replaced. Procedure ,
main control valve for maintenance Care must be exercised to avoid
work on the fire protection system Contact your local distributor for avail
which it controls, permission to shut damage before,during,and after instal- ability.When placing an order,indicate
down the affected fire protection lation. Sprinklers damaged by drop- the full product name and part number
system must be obtained from the ping, striking, wrench twist/slippage, (P/N).
authorities and allpersonnel or the like, must be replaced.
proper Sprinkler Assemblies
who may be affected by this action The owner is responsible for the Specify:Series LFII(TY2534)4.9K Res-
must be notified. inspection,testing,and maintenance of idential Concealed Pendent Sprinkler,
Absence of a Cover Plate may delay the their fire protection system and devices P/N(specify):
sprinkler operation in a fire situation. in compliance with this document, as 155°F(68°C) 51-549-1-155
well as with the applicable standards 200°F(93°C) 51-549-1-200
When properly installed, there is an of the NATIONAL FIRE PROTECTION
air gap between the lip of the Cover ASSOCIATION,for example, NFPA 25, Note: Sprinkler and Cover Plates are
Plate and the ceiling. The Cover Plate in addition to the standards of any other separately sold. See below for Cover
assembly has a nominal 3/32(2,4 mm) authorities having jurisdiction.Contact Plate ordering information.
air gap, as shown in Figure 2. This air the installing contractor or product Cover Plate Assemblies
gap is necessary for proper operation manufacturer with any questions. Specify: LFII Concealed Sprinkler
of the sprinkler by allowing heat flow The owner must assure that the sprin- Cover Plate Assembly, temperature
from a fire to pass below and above the klers are not used for hanging rating (specify), (specify) finish, P/N
Cover Plate to help assure appropriate g g any ( py)' ( py)
release of the Cover Plate in a fire situ- objects and that the sprinklers are only (specify):
be repainted cleaned by means of gently dusting 139°F(59°c)
ation. If the ceiling is to
after the installation of the Sprinkled with a feather duster; otherwise, non- Ivory(RAL1015) 56-891-0-135
care must be exercised to ensure that operation in the event of a fire or inad- Bright chrome 56-891-9-135B
vertent operation may result. Beige(RAL1001) 56-891-2-135
the new paint does not seal off any of Pure White(RAL9010)" 56-891-3-135 -
the air gap. Automatic sprinkler systems should be Signal White(RAL9003)"" 56-891-4-135
inspected,tested,and maintained by a Grey White(RAL9002) 56-891-5-135
Factory painted Cover Plates must not Brown(RAL8028) 56-891-6-135
be repainted.They should be replaced, Qualified Inspection Service in accor Black(RAL9005) 56-891-7-135
if necessary, by factory painted dance with local requirements and/or Brushed Brass 56-891-8-135
units. Non factory applied paint may national codes. Brushed Chrome 56-891-9-135
adversely delay or prevent sprinkler custom Paint 56-891-X-135
operation in the event of a fire. 165°F(74°C)
Ivory(RAL1015) 56-891-0-165
Bright Chrome 56-891-9-165B
Beige(RAL1001) 56-891-2-165
Pure White(RAL9010)" 56-891-3-165
Signal White(RAL9003)** 56-891-4-165
Grey White(RAL9002) 56-891-5-165
Brown(RAL8028) 58-891-6-165
Black(RAL9005) 56-891-7-165
Brushed Brass 56-891-8-165
Brushed Chrome 56-891-9-165
Custom Paint 56-891-X-165
* Eastern Hemisphere sales only
"" Previously known as Bright White II
Note:All Custom Cover Plates are painted
using SHERWIN-WILLIAMS Interior Latex
Paint.Contact Johnson Controls Customer
Service with any questions related to custom
orders.
Sprinkler Wrench
Specify: W-Type 42 Sprinkler Wrench,
P/N 56-000-1-079
TFP446
Page 6 of 6
1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 0 2021 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson �(I NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls
TEFLON Is a trademark of The Chemours Company FC,LLC,INCONEL is a registered trademark of Special Metals Corporation;
SHERW IN-W ILLIAMS is a registered trademark of SWIMC LLC
tqcci Fire & Building
Products
rapid response
HOME FIRE SPRINKLER SYSTEM
Technical Services:Tel: (800)381-9312/Fax: (800)791-5500
BlazeMaster ®
CPVC Fire Sprinkler Pipe & Fittings
Submittal Sheet
General Technical
Description Data
Tyco Fire &Building Products (TFBP) Sizes
BlazeMaster CPVC Pipe and Fittings 3/4"to 3"
are designed exclusively for use in wet
Maximum Working Pressure
pipe automatic fire sprinkler systems. 175 psi
They are made from a specially devel-
oped thermoplastic compound com- Approvals
posed of post chlorinated polyvinyl UL, FM, CUL, NSF, Dade County, e
chloride(CPVC)resin and state of the LPCB,MEA,and the City of Los Ange-
art additives. TFBP BlazeMaster les. (Refer to IH-1900, Rev. 0, Janu ...„
CPVC products are easier to install ary 2005 "Installation Instruction & " •
than traditional steel pipe systems, Technical Handbook" for exact list-
and at the same time,provide superior ing/approval information.)
heat resistance and strength as corn- Manufacture Source
pared to traditional CPVC and PVC •
U.S.A.
piping materials used in the plumbing
trade. Various adapters are available Material
to connect CPVC pipe to metallic pip- . Pipe:ASTM F442, SDR 13.5
ing. All female pipe thread adapters
have brass inserts for durability. • Fittings: ASTM F438 (Sch. 40) and
Grooved adapters connect directly to ASTM F439(Sch.80),ASTM F1970
grooved end valves and metallic pipe, Color
with flexible grooved end couplings. Orange
WARNING
Tyco Fire& Building Products (TFBP)
BlazeMaster CPVC Pipe and Fittings
described herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
BlazeMasters is a registered trademark
of Noveon IP Holding Corp.
Page 1 of 6 JANUARY, 2006 TFP1915
•
Page 2 of 6 TFP1915
WATER
NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT.OF PIPE WEIGHT PER LIFT
SIZE O.D. I.D. lbs./ft. lbs./ft. PER LIFT lbs.
3/4" 1.050" 0.874" 0.18 0.44 7875 1339
1" 1.315" 1.101' 0.26 0.67 5040 1320
1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191
1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213
2" 2.375" 2.003" 0.84 2.20 1260 1084
2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531
3" 3.500" 2.952" 1.87 4.83 720 1344
FIGURE 1—PIPE DIMENSIONS
Installation Care and
Tyco Fire and Building Products Maintenance
(TFBP) BlazeMaster CPVC Pipe and
Fittings are to be installed in accord- The owner is responsible for the fin-
ance with IH-1900, Rev. 0, January spection, testing, and maintenance of
2005"Installation Instruction&Techni- their fire protection system and de-
cal Handbook". vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any
authority having jurisdiction. The in-
stalling contractor or product manufac
turer should be contacted relative to
any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service in accordance with
local requirements and/or national
codes.
NOTES
Before closing a fire protection system
control valve for inspection or mainte-
nance work on the fire protection sys-
tem that it controls,permission to shut
down the affected fire protection sys-
tem must first be obtained from the
proper authorities and all personnel
who may be affected by this action
must be notified.
After placing a fire protection system
in service,notify the proper authorities
and advise those responsible for moni-
toring proprietary and/or central sta-
tion alarms.
•
TFP1915 Page3of6
FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT
TYPE NUMBER (T/O) (lb.)
•
TEE 80000 3/4" 5/8" 40 0.11
T/O 80001 1" 11/16" 40 0.19
%,. =.f_ 80002 1-1/4" 7/8" 40 0.26
MIR. 80003 1-1/2" 1-1/16" 80 0.51 •
.��. 1 80004 2" 1-3/8" 80 0.90
J
80005 2-1/2" 1-9/16" 80 1.59
T/O ■■ T/O 80006 3" 1-13/16" 80 2.41
XxYxZ X Y Z
80132 3/4"x 3/4"x 1" 3/4" 3/4" 5/8" 40 0.14 •
80133 1"x 3/4"x 3/4" 9/16" 9/16" 3/4" 40 0.14
80134 1"x 3/4"x 1" 3/4" 11/16" 3/4" 40 0.17
80260 1"x 1"x 3/4" 5/8" 5/8" 13/16" 40 0.16
80135 1-1/4"x 1"x 3/4" 5/8" 5/8" 15/16" 40 0.21
80136 1-1/4"x 1"x 1" 3/4" 3/4" 15/16" 40 0.22
80137 1-1/4"x 1"x 1-1/4" 15/16" 15/16" 7/8" 40 0.26
REDUCING TEE 80261 1-1/4"x 1-1/4"x 3/4" 5/8" 5/8" 7/8" 40 0.23
80262 1-1/4"x 1-1/4"x 1" 3/4" 3/4" 7/8" 40 0.26
Z 80138 1-1/4"x 1-1/4"x 1-1/2" 1" 1" 1" 80 0.43
k••/ T/0
80140 1-1/2"x 1-1/4"x 3/4" 9/16" 9/16" 1" 80 0.36
.��- 80141 80263 1-1/2"x 1-1/4"x 1" 9/16" 9/16" 1-1/16" 80 0.38
1-1/2"x 1-1/2"x 3/4" 9/16" 9/16" 1" 80 0.36
X.■■.Y 80264 1-1/2"x 1-1/2"x 1" 9/16" 9/16" 1-1/16" 80 0.38
�����I'" 80275 1-1/2"x 1-1/2"x 1-1/4" 7/8" 7/8" 1" 80 0.45
T/O •• T/O 80265 2"x 2"x 3/4" 3/4" 3/4" 1-3/8" 80 0.61
•
80266 2"x 2"x 1" 7/8" 7/8" 1-3/8" 80 0.66
80274 2"x 2"x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 0.74
80267 2"x 2"x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78
80271 2-1/2"x 2-1/2"x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 .
80272 2-1/2"x 2-1/2"x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46
80273 2-1/2"x 2-1/2"x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48
80276 2-1/2"x 2-1/2"x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50
80270 3"x 3"x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28
80268 3"x 3"x 2" 1-13/16" 1-13/16" 1-3/4" 80 2.25
80269 3"x 3"x 2-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.44
CROSS&REDUCING CROSS 80009 3/4" 9/16" 40 0.13
�..j- T/O 80010 1" 11/16" 40 0.23
34
J _ 80011 1-1/4" 15/16" 40 0.34
.IL. 80012 1-1/2" 1-1/16" 80 0.67
-IF.■ 80013 2" 1-5/16" 80 1.00
1� 80014 2-1/2" 1-9/16" 80 1.91
O.,II T/O 80008 3" 1-13/16" 80 2.89
T/O ■■ T/O 80015 1"x 1"x 3/4"x 3/4" 7/8" 40 0.28
80025 3/4" 5/8" 40 0.09
REDUCING ELBOW 80026 1" 3/4" 40 0.14 r
80027 1-1/4" 7/8" 40 0.21
X 80028 1-1/2" 1-1/16" 80 0.40
I../ T/O 80029 2" 1-5/16" 80 0.79
,'�j- 80030 2-1/2" 1-9/16" 80 1.14
80031 3" 1-13/16" 80 1.82
v....Y ' XxY X Y
-T/O
80032 1"x 3/4" 11/16" 13/16" 40 0.16
FIGURE 2-FITTING DIMENSIONS(Part 1 of 4)
Page 4 of 6 TFP1915
FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT
TYPE NUMBER (T/O) SCHD. (lb.)
45°ELBOW 80050 3/4" 3/8" 40 0.08
T/O - 80051 1" 3/8" 40 0.11
4 80052 1-1/4" 3/4" 40 0.20
''`4'� 80053 1-1/2" 1/2" 80 0.31
T/O ��S�II. 80054 2" 3/4" 80 0.56
���1i� 80055 2-1/2" 13/16" 80 0.89
80056 3" 1" 80 1.19
80075 3/4" 1/8" 40 0.07
COUPLING& 80076 1" 1/8" 40 0.11
REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12
''i '' 80078 1-1/2" 3/16" 80 0.25
80079 2" 3/16" 80 0.38
^rrNrr 80080 2-1/2" 1/4" 80 0.67
--T/O 80081 3" 3/16" 80 0.91
80220 1"x 3/4" 1/8" 40 0.08
80200 1"x 3/4" 7/16" 40 0.04
80201 1-1/4"x 3/4" 1/2" 40 0.11
80202 1-1/4"x 1" 5/16" 40 0.12
80203 1-1/2"x 3/4" 5/8" 80 0.16
80204 1-1/2"x 1" 1/2" 80 0.14
REDUCER BUSHING 80205 1-1/2"x 1-1/4" 3/8" 80 0.17
80206 2"x 3/4" 13/16" 80 0.27
-'%17 80207 2"x 1" 11/16" 80 0.26
80208 2"x 1-1/4" 9/16" 80 0.24
"T /,L, 80209 2"x 1-1/2" 7/16" 80 0.19
-I 1 T/O 80215 2-1/2"x 1" 15/16" 80 0.42
80214 2-1/2"x 1-1/4" 13/16" 80 0.45
80213 2-1/2"x 1-1/2" 11/16" 80 0.46
80211 2-1/2"x 2" 5/8" 80 0.29
80210 3"x 2" 3/4" 80 0.72
80212 3"x 2-1/2" 1/2" 80 0.47
CAP 80100 3/4" 5/16" 40 0.04
80101 1" 3/8" 40 0.06
80102 1-1/4" 7/16" 40 0.10
80103 1-1/2" 11/16" 80 0.20
1 I 80104 2" 5/8" 80 0.31
T/O-I - 80105 2-1/2" 7/8" 80 0.58
80106 3" 1" 80 0.88
GROOVED T/O PIPE O.D.
COUPLING ADAPTER
llt 80160 1-1/4"x 1-1/4"Groove 2-5/16" 1-1/4"(1.660") 40 0.78
80161 1-1/2"x 1-1/2"Groove 2-5/16" 1-1/2"(1.900") 80 0.95
1.42
PIPE 80162 2"x 2"Groove 2-5/16" 2"(2.375") 80
O.D.
80163 2-1/2"x 2-1/2"Groove 2-5/16" 2-1/2"(2.875") 80 2.28
80164 3"x 3"Groove 2-1/4" 3"(3.500") 80 3.00
T/O-I 80169 2-1/2"x 76,1 mm Groove 2-5/16" 76,1 mm(3.000") 80 2.28
FIGURE 2-FITTING DIMENSIONS(Part 2 of 4)
TFP1915 Page 5 of 6
FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT
TYPE NUMBER (T/O) (lb.)
SPRINKLER HEAD
ADAPTER
80175E 3/4"x 1/2"NPT 7/16" 80 0.20
"'= 80176E 1"x 1/2"NPT 7/16" 80 0.22
80175WL 3/4"x 1/2"NPT 7/16" 40 0.16
80179 1"x 3/4"NPT 13/16" 40 0.43
- T/O -
SPRINKLER HEAD
ADAPTER
NA 80175W 3/4"x 1/2"NPT 1/2" 40 0.19
80176W 1"x 1/2"NPT 1/2" 40 0.18
- T/O
SPRINKLER HEAD
ADAPTER(SPIGOT)
80177L 3/4"x 1/2"NPT 1/2" 40 0.16
uuu80178 1"x 1/2"NPT 9/16" 40 0.20
mmonm I�,,��. 80180 1"x 3/4"NPT 7/8" 40 0.40
- T/O
FEMALE ADAPTER
��0\\\� 80142 3/4"x 3/4"NPT 13/16" 40 0.41
II 80145 1'x 1"NPT 7/8" 40 0.63
I111 80146 1-1/4"x 1-1/4"NPT 1-1/8" 40 1.03
80147 1-1/2"x 1-1/2"NPT 1-3/8" 80 1.42
/I��J��M\\\\\ 80148 2"x 2"NPT 1-11/16" 80 2.66
T/O
MALE ADAPTER
11110 80158 3/1'x " 1-5/16""" 40 0.56
80158 1'x 1"NPT 1-3/8" 40 0.56
wA ea rm'Mk
-T/O-
XxYxZ X Y Z
SPRINKLER HEAD 80250 3/4"x 3/4"x 1/2"NPT 9/16" 9/16" 1" 40 0.22
ADAPTER TEE
Z 80251 1"x 1"x 1/2"NPT 11/16" 11/16" 1-3/16" 40 0.29
`S,01j T/O 80249 1"x 1"x 1"NPT 15/16" 15/16" 1-9/16" 40 0.73
Lkain
`� ` 80256 1-1/4"x 1"x 1/2"NPT 7/16" 9/16" 1-5/16" 40 0.30
=��� 80252 1-1/4"x 1-1/4"x 1/2"NPT 7/16" 7/16" 1-5/16" 40 0.31
X MEM=Y 1 80257 1-1/2"x 1-1/4"x 1/2"NPT 1/2" 11/16" 1-7/16" 80 0.43
w wii��mr. 80254 1-1/2"x 1-1/2"x 1/2"NPT 1/2" 1/2" 1-7/16" 80 0.46
T/O •• T/O 80258 2"x 1-1/2"x 1/2"NPT 1/2" 5/8" 1-11/16" 80 0.56 ..
80253 2"x 2"x 1/2"NPT 1/2" 1/2" 1-11/16" 80 0.62
FIGURE 2—FITTING DIMENSIONS(Part 3 of 4)
Page 6 of 6 TFP1915
FITTING PART WEIGHT NOMINAL SIZE NOMINAL TAKE-OUT
TYPE NUMBER (T/O) SCHD. (lb.)
• BACK-TO-BACK TEE X x Y x Z X Y Z
X
1„/ T/O
Y'...,,/ _"" 80459 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.48
Illllli�'�=Mill
IM�AIRWIl 1 z 1 80460 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46
T/O -- T/O
XxYxZxW Y x Z x W X,Y Z W
BACK-TO-BACK CROSS
X
/„/ T/O
Z.Cw/ e _.
IIIIIINa11�miIIII11
W
1.971 ila I 80462 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46
1 - f 80463 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.47
T/O I„I
T/O T/O
SPRINKLER HEAD X x Y X Y
ADAPTER 90°ELBOW
Y
M; T/O
.r�1It 80199 3/4"x 1/2"NPT 9/16" 1" 40 0.20
•• 80198 1"x 1/2"NPT 3/4" 1-1/4" 40 0.26
��i►'-X 80196 1"x 3/4"NPT 1-1/16" 1-7/16" 40 0.26
—T/O
FIGURE 2—FITTING DIMENSIONS(Part 4 of 4)
Limited by TFBP to be defective shall be either of merchantability and fitness for a par-
repaired or replaced, at TFBP's sole ocular purpose.
Warranty option. TFBP neither assumes, nor authorizes any person to assume for it, This limited warranty sets forth the ex-
clusive remedy for claims based on
any other obligation in connection with
Products manufactured by Tyco Fire& the sale of products or parts of prod- failure of or defect in products, materi-
Building Products (TFBP) are war- ucts.TFBP shall not be responsible for als or components, whether the claim
ranted solely to the original Buyer for sprinkler system design errors or inac- is made in contract, tort, strict liability
ten(10)years against defects in mate- curate or incomplete information sup- or any other legal theory.
rial and workmanship when paid for plied by Buyer or Buyer's repre- This warranty will apply to the full ex-
and properly installed and maintained sentatives. tent permitted by law.The invalidity, in
under normal use and service. This whole or part, of any portion of this
• warranty will expire ten (10) years In no event shall TFBP be liable, in
from date of shipment by TFBP. No contract, tort, strict liability or under warranty will not affect the remainder.
warranty is given for products or com any other legal theory, for incidental,
ponents manufactured by companies indirect,special or consequential dam-
not affiliated by ownership with TFBP ages, including but not limited to labor
or for products and components which charges, regardless of whether TFBP
have been subject to misuse,improper was informed about the possibility of
installation, corrosion, or which have such damages, and in no event shall
not been installed, maintained, modi- TFBP's liability exceed an amount
fied or repaired in accordance with ap- equal to the sales price.
plicable Standards of the National Fire The foregoing warranty is made in lieu
Protection Association, and/or the of any and all other warranties. ex-
standards of any other Authorities press or implied. including warranties
Having Jurisdiction. Materials found
TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446
Eddythread 40
•
A Lightweight Schedule 40 Replacement Pipe
That Has a Corrosion Resistance Ratio of 1.0
Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe
products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our
customers have an option to buy a carefully designed replacement for Schedule 40 that:
• Has a Corrosion Resistance Ratio of 1.0
• Has a Pressure Rating of 300 psi
• Is Lighter Weight Than Schedule 40
• Is Approved by Factory Mutual and Listed by Underwriters Laboratories
• Is Produced in Accordance to ASTM A-135 and A-795
• Can be Used With Standard Schedule 40 Threaded Fittings,
Couplings and Valves
• Is Produced From Steel With Excellent Properties of
Strength and Threadability
• Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems*
• Offers Lower Freight Costs
EDDYTHREAD 40 SPECIFICATIONS
' .NOMINAL'PIPE SIZE III)t . PG O I.D. 00,.. : BUNDLE SIZE .. . .,
1 1.461 1.083 70
1 1/4 2.070 1.418 51
1 1/2 2.547 1.654 44
2 3.308 2.123 30
CORROSION RESISTANCE RATIOS
NOMINAL PIPES SCHEDULE 40 EDDYTHREAD 4
1 1.00 1.00
1 1/4 1.00 1.00
1 1/2 1.00 1.00
2 1.00 1.00
*Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems
1819 Clarkson Road For additional information, g`UaUS
Chesterfield,MO 63017 contact your salesperson today at ilk
�� Rq A I To conp.NY (800)325-4467 (800)325-4467 or(636)537-2600
FAX:(636)537-2645 in the USA,or from Canada
www.bullmoosetube.com call(800)882-4666 41> •
A(CA R O company e-mail:salesAbullmoosetube.com APPROVED
All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08
o
P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org
510
CPVC - COPPER - STEEL
I
HANGER
5, Fastener
SIZE DIm
4-ri
3/4 2.125
Q 1 2.312
1 1/4 3.170
11/2 3.400
2 4.010
2 1/2 4.320
3 5.320
SIZE-SYSTEM PIPE: 3/4"thru 3"
• MATERIAL-Carbon Steel.
FINISH-Mil.Galvanized.
LISTING/APPROVAL-
°D�aa'203-EX4231,EX2551
FUNCTION-Support horizontal piping: CPVC,Copper or Steel.
Size 3/4"-2"Prevents upward movement of pipe from pendent sprinkler discharge.
Stabilize vertical piping.
INSTALLATION- Per these instructions
including NFPA 13, 13R, 13D and CPVC manufacturers instructions.
Install on horizontal or vertical mounting surface.
FASTENERS- UL Listed per NFPA 13
in WOOD:
3/4" -3"CPVC pipe-#905 screw-no pre-drill.
3/4"-3" Steel and Copper pipe-#14 x 1 1/2" SMS or
1/4"xl1/2"lag bolt-no pre-drill. Restraint
in STEEL-min. 18 GA.
3/4"-3"CPVC,Copper and Steel pipe- 1/4"or#14 Tek Screw.
FEATURES
*Offset edge eliminates abrasion.
*Retainer dimples secure hanger to pipe during installation.
*Required AFCON#905 screw included-5/16"hex head. Hanger Stabilize
• ORDERING-Part#and pipe size.
1
CAN ALSO BE USED TO REPLACE-#500 Pipe Strap h1'
#520 Tin Strap
Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly.
Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems
not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not
limited to loss of business or profit,when non-AFCON products have been,or are used.
5/14
�' /ANVIL
CPVC �t--�A/11,.
Fig. 188R(Formerly Afcon Fig. 514) iWo Hole Standoff and Restrainer
Size Range:3/4"through 2" - •
Material:Carbon Steel
Finish:Pre-Galvanized per ASTM A653 " -. C 03 US
LISTED
Service:
• Hanger and surge restraint for horizontal CPVC piping when installed on the top,bot-
torn, '�# _.
and side of the supporting structure. ,
• Guide for vertical CPVC piping when installed on the side of the supporting structure.
• Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. y
• Listed with hardware provided on structural wood beams and composite wood beams , t
(1"minimum).Listed with steel(l8ga minimum)with two(2)#14x1"or'/a"xl"hex washer `,r* . t
head self-drilling TEK screws.For wood structures with less than 1"thickness,wood
blocks may be placed on the backside of the wood structure.#10x1"fastener provided
must be fully engaged in the wood block.
• May be installed with concrete,steel structural members,and other structural *`
members with fasteners which comply with the requirements of NFPA 13.
Approvals:cULus Listed
Patents:No.6,648,278
Installation:
• Snap hanger over pipe. If needed,squeeze strap back around pipe.
• CPVC pipe must be allowed to slide freely through the Fig.188R. •
• Secure hanger to mounting surface with screws provided or with listed fasteners.
Features: • ~411)• Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. i.so •
• Easily attaches to wood structure with#10 x 1"hex washer head self-threading screw supplied with yam►.
product.No pre-drilling required.
• Bottom of pipe is offset 11/2'from the structure. Eliminates wooden spacer blocks.
•
Ordering:Specify CPVC pipe size,figure number and description. •
Hanger&
Restrainer Mill
IVI■,\
Iii Installation-Backing Nut
Hanger=1-at top fastener
Restraint=2-on each fastener
7
Hanger& � Guide& Per NFPA-13D and NFPA-13R
Restrainer ���_ Restrainer
(Il
PROJECT INFORMATION APPROVAL STAMP
Project: Approved
Address: ❑Approved as noted
Contractor: ❑Not approved
Engineer: Remarks:
Submittal Date:
Notes 1:
Notes 2:
PH-1.18
CPVC z' 4nwi
Fig. 188R(Formerly Afcon Fig. 514) 'Itvo Hole Standoff and Restrainer(cont.)
a a 4 I B
as
a a 4 t / r ,_ 1 \
a IEE -�- (5 oC
a
4
A .. t /
-Q b 4
4
a
a as as
a a d a
a a ArM
'w w`
F
D
O
„
Hanger and Restrainer
FIG. 188R: DIMENSIONS (IN) • WEIGHT (LBS)
' CPVC A B aC 0 E F G Max. Hanger Approx.
Pipe Size Spacing(FT.) Weight/100(Ibs)
3/4 23/4 31/z 1/4 2 1 25A 11/2 51/2 11
1 213/6 31/2 1/4 23/6 1 2t5/6 11h 6 12
11/4 273/6 31/2 1/4 25A6 1 31/4 11/2 61/2 13
11/ 35/6 41/4 1/4 27/6 1 31/2 11/2 7 14
2 311/6 43/6 1/4 211A6 1 4 11/2 8 16
PH-1.18