Loading...
Permit (8) (115T2023- ooORECEIVED 114 8j Cityof Tigard g d Building Division MAR 0 9 2023 13125 SW Hall Blvd,Tigard,OR 97223 CITY OF TIGARD Phone: 503.718.2439 Fax: 503.598.1960 BUILDING DIVISION TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 11020 SW Cottonwood Ln City: Tigard Zip: 97223 Owner's Name: Oscar Quinal Date: 03-08-2023 Contractor's Name: ION Developer LLC CCB #: 230394 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? X❑ No OSSC or ORSC for design requirements. Is the wind exposure Yes Wind Exposure P If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑x Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for labovabove e Yes the prescriptive path. ❑ No I:/Building/Forms/Photovoltaic-Checklist02-01-11.docx 1 Document Ref GSWB9-9C57D-2KUPJ-QZQKJ Page 4 of 7 • Is the construction material wood and does X❑ Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑X Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight X❑ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance X❑ Yes with Section 305.4(3)of If"Yes", qualifies for ❑ the 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is RoofingCheck the type of ❑ of wood Yh one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. E of composition shingle. Is the roof mounted X❑ Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 L•/Building/Forms/PhotoVoltaic-Checklist02-01-1 l.docx p.oum t 12E rB9 9G57D,PW- IKJ Pag 17 n Yes If"Yes" Is the gauge 26 or less? , qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? n Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members n No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof n Yes the prescriptive path. surface. ❑ No 3 I.•/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Document Re# 1A pwwo-2 1-Q4t_KJ Page fi 7 4,,..15 Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: SILFAB Model Number: SIL-400 HC+ Listing Agency: 4 L•/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx 0 :.nt Ref:4 7#65/p a i:ozoK i x K F?a a"7 of 7 n" :�:�1 •�����. '.••••: s 4 Signature Certificate : ..• ... .•. ..... Reference number:GSWB9-9C57D-2KUPJ-QZQKJ ••••••. ••• •.:.• •i a i�i:' Pi0` •••••• • :••:.' Signer Timestamp Signature ':•V.:, Dustin Davidson •�;� •••,•4 Email:dustin.davidson@ionsolaccom .••••; L:27aiis.Sent: 08 Mar 2023 1618:57 UTC •,•,••• y%;; Signed: 08 Mar 2023 16:18:58 UTC _ •:•:, �%% IP address:136.41.65.14 1 , ���; Location:Springville,United States ,••••, ♦• VV. '.•;+; Document completed by all parties on: �':•:' 44: 08 Mar 2023 16:18:58 UTC ••• •.•• Page 1 of 1 ••; ••. •••• .'.•.', ;•�•; ,•❖. •••: ••: Ji:' '.., .••1: 914,4, .❖: V... 41,41. W. •••. {•, ,,.,.• •...1.. •••• ,..• ♦•' •••. •,•,•• .•• •4•. :%,; Signed with PandaDoc CI• , El ;.•;; Att.' PandaDoc is a document workflow and certified eSignature •• r ;4 r' T. •., :•••; solution trusted by 40,000+companies worldwide. ❑I r p— .•••••, •••. •�•'i'•i'i i Oi;:k•..-.-.• i ii ii i i4•ii i i i•Ji i i•i iii'ii iii iii'iii ii iii i i i i i i iii;•i':Oi i ii ;.;ii i'i i;this/••• CITY OF TIGARD MASTER PERMIT IIICOMMUNITY DEVELOPMENT Permit#: MST2023-00081 Date Issued: 05/15/2023 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1 S134ACO2644 Jurisdiction: Tigard Site address: 11020 SW COTTONWOOD LN Subdivision: ENGLEWOOD NO.3 Lot: 210 Project: Quinal Project Description: PV system 5.6 kW and(2)0-30A circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $3,920.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add''500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 5.6 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: QUINAL,OSCAR&LEONIDA ION DEVELOPER LLC Required Items and Reports(Conditions) 11020 SW COTTONWOOD LN 3214 NORTH UNIVERSITY AVE TIGARD,OR 97223 503 PROVO,UT 84604 PHONE: PHONE: 888-781-7074 FAX: Total Fees: $457.42 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QS9_nn1_M1 n thrni inh(lA oc9_nnl_nflo Vn,,. w nhtoin m rnn,,of fho n doe nr rlirort n,mctinne to(ll iM( by r.11inn cna 739 10317 nr 1 Ann T19 91dd �Issued By: ~'/ G "f Permittee Signature: "` Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. - -a Building Permit Application Residential RECEIVED ED FOR OFFICE USE ONLY City of Tigard Received � �r Date/B Alt Permit No.:�,r , —eaa II . 13125 SW Hall Blvd.,Tigard,OR 97223 MAR U 2023 Plan Review w, s Phone: 503.718.2439 Fax: 503.598.1960 Date/B : �� ),..4 Other Permit: p iI �A I I G A R t3 Inspection Line: 503.63 94175 CITY OF TIGARD Date Ready/By: s ARM ions: ® Sec Page 2 for Internet: www.tigard-or.gov Notified/Method 2� ��� Supplemental Information BUILDING DIVISION ;;� �aul girl _ TYPE RIC"' # x { UIRED DALA AN 2-FAMITY DWELT ING" 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®Other: PV Solar equipment,materials,labor,overhead,and the profit for the 44 1 i;CATEGORY 6F CONSTRUCTION ` work indicated on this application. ® 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ 3,920 ❑Accessory building ID Multi-familyNumber of bedrooms: IDMaster builder 0 Other: Number of bathrooms: JOB SITE INFORMATIONAND.,...LOCATION, Total number of floors: Job site address: 11020 SW Cottonwood Ln New dwelling area: square feet City/State/ZIP: Tigard,Oregon 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Quinal Solar Install Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet „REQU.IRED ATA:COMMERCIAL-USE CHECKLIST Subdivision: Englewood No 3. Lot no.: 210 Permit fees*are based on the value of the work performed. Tax map/parcel no.: 1 S 134ACO2644/R264109 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of solar panels on existing residential roof. Valuation: $ 5.6 kW.Addition of 2 0-30A circuits. Existing building area: square feet New building area: square feet El PROPERTY'OWNER ❑:TENANT; Number of stories: Name: Oscar Quinal Type of construction: Address: 11020 SW Cottonwood Ln Occupancy groups: City/State/ZIP: Tigard,Oregon 97223 Existing: Phone:((808)1673-3782 Fax:( ) New: APPLICANT— x.: L3 CONTACT'PERSON ':.1. BUILDING PERI�pT FEES* Business name: ION Developer LLC (Please refer to/ee`scheauk)' Structural plan review fee(or deposit): Contact name: Dustin Davidson FLS plan review fee(if applicable): Address:4801 N University Ave#900 City/State/ZIP: Provo, UT 84604 Total fees due upon application: Phone:( 888) 781-7074 Fax::( ) Amount received: E-mail: permits@IOnSOIar.COm PHOTOVOLTAI�C%SOLAR PANEL SYSTEM FEES*" , - .., . " '�="u �� �, Commercial and residential prescriptive installation of CONTRACTOI t p '� _ rr v roof-top mounted Photovoltaic Solar Panel System. Submit two(2)sets of roof plan with connection details Business name: ION Developer LLC and fire department access,along with the 2010 Oregon Address: 4801 N University Ave#900 Solar Installation Specialty Code checklist. City/State/ZIP: Provo, UT 84604 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 888) 781-7074 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: 230394 Total fee due upon application: $201.60 Authorized signature: it , This permit application expires if a permit is not obtained f .^"` within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name: Dustin Davidson Date: 03-08-2023 Service Board. I:\Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Document'Ref:GSWB9=9C57D-2lWlaJ-QZ(3kJ"t=;' Page 1 of 7 Electrical Permit Application Fit:C E FOR OFFICE USE ONLYI t..w City of Tigard Received Date/By: Permit#: 13125 SW Hall Blvd.,Tigard,OR 97223 R U 9 2023 Plan Review I Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#: /757 ZO23.00O2c' Inspection Line: 503 639.4175 Ready Date/By: Jmis: ® See Page 2 for I I( 1 R 11 Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: Supplemental Information BUILDING DIVISIG ' ",. . *PEO WORK ..; i k ! .: ° ,AN I2E D New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Demolition0 Service or feeder 400 amps or more 0 Building over three stories. ®Other: PV Solar h h�.� t� x, � k where the available faultcurzent Marinas and boatyards. is, r'r. 7i 2ik CAtEGORY CG! t TIO ` t;'�:.. )�, t . exceeds 10,000 amps at 150 volts or 0 Floating buildings. ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑ amps for all other installations. buildings. ❑Multi-family 0 Master builder Other: hn h - ��"„ M . Fire pump. 0 Installation of 150 KVA or JOB SITE IrRTION.AND LOCATION ,, ❑Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 11020 SW Cottonwood Ln IOOI-IP or more. ❑°°A",'`E' "I-z",°'I-s", City/State/ZIP: Tigard, Oregon 97223 ❑Six or more residential units. occupancy. 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: Quinal Solar Install 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: a. y_EEy SCHEDULE Description '1 Qty.l Each I Total I " New residential single-or multi-family dwelling unit. Subdivision: Englewood No 2. Lot#: 210 Includes attached garage. Tax map/parcel#: 1 S 134ACO2644/R264109 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 ,. °n t 'DESCRIPTION OF-WORK " Limited energy,residential 75.00 2 Installation of solar panels on existing residential roof. (with above sq.ft.) Limited energy,multi-family 75.00 2 5.6 kW.Addition of 2 0-30A circuits. residential(with above sq.ft.) „, Renewable Energy 0 See Page 2 �..PROP."ERTY OWNIR, ;; 1, - „,,, 0 TENANT';., Services or feeders installation,alteration,and/or relocation Name: Oscar Quinal 200 amps or less 100.70 2 Address: 11020 SW Cottonwood Ln 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard, Oregon 97223 601 amps to 1,000 amps 301.04 2 Phone:((808))673-3782 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: oscarquinal@icloud.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ►:i'."APPLICANT "' 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel � A.Fee for branch circuits with Business name: ION Developer LLC above service or feeder fee, 7.42 2 each branch circuit Contact name: Dustin Davidson B.Fee for branch circuits without service or feeder fee,first Address: 4801 N University Ave#900 branch circuit 1 56.18 56.18 2 City/State/ZIP: Provo, UT 84604 Each add'l branch circuit 1 7.42 7.42 2 Miscellaneous(service or feeder not included) Phone:( 888) 781-7074 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: permits@ionsolar corn Reconnect only 67.84 2 ;: .• CONTRACT.©II ,.. Pump or irrigation circle 67.84 2 Business name: ION Developer LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 4801 N UniversityAve#900 0 See Page 2 2 panel,alteration,or extension. City/State/ZIP: Provo, UT 84604 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(888) 781-7074 Fax:( ) Investigation(1 hr min) 90.00/hr Email: Industrial plant(1 hr min) 78.18/hr permits@ionsolar.com Inspections for which no fee is CCB Lie.: 230394 Electrical Lie.: C1524 Suprv.Lie.: 6098S specifically listed(�V5 hr min) 90.00/hr ;}# ELECTRICALtXRIVIIT FEES " �a r" Suprv.Electrician signature,required: ",, /r2�f Subtotal: 197.16 Print name: David S Conrad G Date: 03-08-2023 0 Plan Review Required(25%of permit fee): � State surcharge(12%of permit fee): 23.66 Authorized signature: �'Yr rr.m oa,r ,+r , TOTAL PERMIT FEE: 220.82 This permit application expires if a permit is not obtained within 180 Print name: Dustin Davidson Date: 03-08-2023 days after it has been accepted as complete. * Number of inspections allowed per permit. 1:\Building\Permits\ELC PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Document Ref;GSWB9-9C57I7-2KUPJ-QZQKJ.' Page 2 of 7;`"` Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Fee for all residential systems combined: $75.00 Description Qty. Each Total * Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ A• udio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 ❑ G• arage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is s ecifically listed(V2 hr mm) 90 00/hr Fee for each commercial system: $75.00 Subtotal(Enter n Page 1): 133.56 (SEE OAR 918-309-0000) * Number of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems El Landscape Irrigation Control* ❑ M• edical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ P• rotective Signaling ❑ O• ther: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 r , ,' Document f :. Il � PJ QZQKJ '