Report o `
Ore on Residential Specialty Code R318.2
MOISTURE CONTENT
ACKNO WLE I GEMENT FORM
I :A.n , am the general contractor or the owner-builder
at the following address:
Site Address: 190 e'.., ' o& Pk LN
City: I'c,a-d — —
Permit #: J/
MI 202I— 06 314 S__
Subdivision/Lot t:
'7)1%.4.r "re,r ro.c.Q =RoShak L.o r fr,t 2.33
and/or
Map and Tax Lot 4:
To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry fi-aming members.
Signature: _ - Date: b 12.02 3
General C ctor or Owner-Builder
ABuilding\Formesfl s-r\toistllre.;ensiiivcwood dnr. IlO/25/0
I .
A
•
Oregon Residential Specialty Code WWI
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, Y';ash a. Sra.C,x-- __.._ , am the general. contractor or the owner-builder
at the following address:
Site Address:
► CI' 90 S OCk40m 101 Lnl
City: T5 arKci — -- —
Permit#: M5T 20Z( 00 Ski 3
Subdivision/Lot##: 2 er I erIrAce - 4514- Coq--#.' 2 3 3
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in OR.SC Section 408.1 and have taken the following steps to meet this code
requirement:
Lam - '.the ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting itli
L _lot is lapped. 12.. at seams and
Extending up the foundation walls 12".
Signature: 1 Date: g/2,6 lzo23
eneral Contrac, or or Owner--_ illler
l.ABuilding\Dorm\R1 S-Moicturcliarrier.doc l9/13/21)I(
Oregon Residential Specialty Code N1107o2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
PermitNo.: loci" 7ZJ - 6o313 Jurisdiction: ,rd —
Site Address: `6 7-90 CJ. 0) ecGi 11 amPto /- L/0
Subdivision/Lot#: Atver Grtrac.,e, - QOSLal. tar 2
and/or
Map and Tax Lot It:
By ray signature below, 1 certify that a minimum of fifty (50) percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code Nl 107.2)1
Signature: _ Date: 4"/z4/zo 23
Owner/Ge a Contractor/Authorized Agent
Print Name: jkrj_,_______r2Z__4ze_
' OItSC Section N1107.2. I-Iigh-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent, or a lighting source that
has a minimum efficacy of.10 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of,10 lumens per
input watt.
LABuildingAFinns\ (he (MO 1/08