Loading...
HomeMy WebLinkAboutSpecifications m5-7 2z-ao % RECEIVED ION Solar p' MAY I 0 2023 4801 N University Ave.Suite 900 ION CITY 17 Ti V 'Pr) Provo,UT 84604 B LD NG Di ON luke.rowley@ionsolar.com Friday,April 21,2023 RE:Chris T Newell Residence-10060 Southwest 72nd Avenue,Portland,Oregon To Whom It May Concern: I have evaluated the roof structural elements of the residence for the required design loads and the additional load that will be imposed by the proposed solar system.The existing roof information was provided by a site visit by an audit team at ION Solar. Based on that site visit,it is my understanding that the roof framing information is as follows: Roof Structure: 2x6 Rafters @ 24"O.C. Roofing Material: Composition Shingle The Required codes and loads are as follows: Codes: 2019 OSSC,2021 ORSC Risk Category: II Wind Speed(3-Sec Gust, MPH): 96 Exposure Category: B Ground Snow Load(psf): 36 OFFICE COPY Roof Snow Load(psf): 26 Roof Live Load(psf): 20(superseded by roof snow load) After reviewing the existing roof framing information and in accordance with the structural calculations on sheet S-5 of the plans,which were performed according to the applicable codes and loads above,it is my recommendation that the existing roof framing requires additional 2x6 rafters be sistered to the existing rafters on RS1&RS2,according to detail I on sheet S-4 of the plans,to safely and sufficiently support the required structural design loads and the weight of the new solar system.Only rafters with a span longer than 9'need to be upgraded. This evaluation only applies to the areas of the roof that will be directly supporting the solar system and does not make any recommendations for any other structural components of the building.The racking must be installed per the manufacturer's recommendations. The 5/16"x 3-1/2"zinc plated steel lag screw used to attach the solar system to the roof must be staggered to evenly distribute the loads over the affected area and must penetrate the rafters with a minimum embedment depth of 2.5" 03) PROFESS THIS LETTER VOID UNLESS STAMPED Sincerely, N EFL 429 A. Luke Rowley, PE 9 950P r. 4GON N „ 20 c:".._)REGON,) N RO`N /03/2023 EXPIRES:12/31/24 19 ;, , pt • ••. ••••• ••• SILFAB PRIME SILFAB SOLAR SIL-400 HG+ RELIABLE ENERGY. • PROUD DIRECT FROM THE SOURCE . PPARTNEROF Designed to outperform. Dependable, durable, high-performance ION solar panels engineered for North American homeowners. SILFABSOLAR.COM ELECTRICAL SPECIFICATIONS 400 Test Conditions STC I NOCT Module Power(Pmax) Wp 400 298 Maximum power voltage(Vpmax) V 36.05 33.50 Maximum power current(Ipmax) A 11.10 8.90 Open circuit voltage(Voc) V 43.02 40.35 Short circuit current(Isc) A 11.58 9.34 Module efficiency 0/ 20.2% 18.8% Maximum system voltage(VDC) V 1000 Series fuse rating A I 20 • Power Tolerance Wp 0 to+10 Measurement conditions:STC 1000 W/m'•AM 1.5•Temperature 25°C•NOCT 800 Wm'•AM 1.5•Measurement uncertainty<_3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. MECHANICAL PROPERTIES(COMPONENTS METRIC , IMPERIAL Module weight 21.3kg±0.2kg 471bs±0.41bs Dimensions(H xL x D) 1914mm x 1036mm x 35mm 75.3 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)" 5400 Pa rear load/5400 Pa front load. j 112.8 lb/ft'rear load/112.8 lb/ft'front load Hail impact resistance 025mm at83 km/h e1 in at 51.6 mph Cells 132 Half cells-Si mono PERC 132 Half cells-Si mono PERC 9 busbar-83 x 166 mm 9 busbar-3.26 x 6.53 in Glass 3.2mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM antireflective coating DSM antireflective coating Cables and connectors(refer to installation manual) 1350 mm,a 5.7 mm,MC4 from Staubli I 53 in,a 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet Frame I Anodized Aluminum(Black) Bypass diodes 3 diodes30SQ0457(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient lsc +0.064%/°C Module product workmanship warranty 25 years"" Temperature Coefficient Voc 0280/0/°C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.36 u0/°C - >_97.1%end 1st yr ±2°C 45°C >_91.6%end 12th yr NOCT ( 2°C) >_85.1%end 25th yr Operating temperature -40/+85°C ', >_82.6%end 30th yr CERTIFICATIONS SHIPPING SPECS > UL 61215-1:2017 Ed.1""",UL 61215-2:2017 Ed1"",UL 61730-1:2017 Ed.1"",UL 61730- Modules Per Pallet: 26 or 26(California) 2:2017 Ed.1"",CSA C222#61730-1:2019 Ed2"",CSA C222#61730-2:2019 Ed2""', Product IEC 61215-1:2016 Ed1""",IEC 61215-2:2016 Ed.1""",IEC 61730-1:2016 Ed.2""",IEC 61730-2:2016 Ed.2"",IEC 61701:2020(Salt Mist Corrosion),IEC 62716:2013(Ammonia Pallets Per Truck I 32 or 31(California) Corrosion),UL Fire Rating:Type 2,CEC Listing'"" '. Factory IS09001:2015. Modules Per Truck II 832 or 806(California) • A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. " 12 year extendable to 25 years subjectto registration and conditions outlined under"Warranty"at silfabsolar.com PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/down loads. """ Certification and CEC listing in progress.December2022,expected completion. 4 i ION L 75.3"[1914mm] _ 'v E T +1888.781.7074 12.1"[307mm] 51.2[1300mm] 12.1"[307mm] IONS O L A R.C O M 7 Hole(x4) _ SILFAB SOLAR INC. -Mounting 1i 800 Cornwall Ave -z-> ) 0.5' 1 Bellingham WA 98225 USA [12mm] T+1 360.569.4733 info@silfabsolar.com / r- 7_ 1, SILFABSOLA R-COM E 1770 Port Drive io E E / <Eo Burlington WA 98233 USA 1.4"[35mm] \o n io E M �i `�I / o T+1360.569.4733 A �--- i /1 _ 01 o 240 Courtneypark Drive East is E o °' Mississauga ON LST 2Y3 Canada cn E= T+1 905.255.2501 �, 0.06" 53.15" a m F+1905.696.0267 l [1.5mm] t I- - [1350mm] Cable Length f` 2 Silfab-SIL-400-HC+-20221114 )=,=7 `-C3 No reproduction of any kind a allowed without Ci permission.Data d'information s subject to ,�DrainageHole(x8) ITImodificationswtn [ T GSdfab Solar Inc . Y +" 2022 r Siifab Solar' areglstered trademark of __ i - - ._J Slfab Solar Inc. L. 2.4"[60mm] 8"[200mm]-.L i EN PHAS E: DATA SHEET 108+ i111 IP IQ8 Series Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- • Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter • Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times • Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability • Produce power even when the Enphase grid is down* • More than one million cumulative hours of testing • Class II double-insulated Part of the Enphase Energy System,I08 Series IQ8 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative • Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. powered PV modules (1110 Microgrid-forming • Complies with the latest advanced grid support** CERTIFIED • Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as • Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. • Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other *Only when installed with IQ System Controller 2,meets names are trademarks of Enphase Energy,Inc.Data subject to change. UL 1741.IQ8H-208V operates only in grid-tied mode. **IQ8 Series Microinverters supports split phase,240V. IQ8SE-DS-0001-01-EN-US-2022-03-17 108H-208 supports split phase,208V only. IQ8 Series Microinverters INPUT DATA(DCI I08-60-2-US IQ8PLUS-72-2-US 108M-72-2-US IQ8A-72-2-US 108H-240-72-2-US IQBH-208-72-2-US' Commonly used module pairings2 W 235-350 235-440 260-460 295-500 320-540+ 295-500+ Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage V 50 60 ' Max DC currents[module Iscj A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA IACI 108-60-2-US I08PLUS-72-2-US IOSM-72-2-US IQUA-72-2-US 108H-240-72-2-US IQ8H-208-72-2-US' Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal(L-L)voltage/range4 V 240/211-264 208/183-250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 3 cycles Arms 2 4.4 Max units per 20 A(L-L)branch circuits 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See the compatibility calculator at https://link.enphase.com/module-compatibility(3)Maximum continuous input DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IO8SE-DS-0001-01-EN-US-2022-03-17 ELECTRICAL SPECIFICATIONS 380 Test Conditions STC NOCT Module Power(Pmax) Wp 380 284 Maximum power voltage(Vpmax) V 35.32 ! 32.83 Maximum power current(Imax) A 10.77 8.64 Open circuit voltage(Voc) V 42.17 39.55 Short circuit current(Isc) A 11.36 9.16 Module efficiency % 20.8% 19.4% Maximum system voltage(VDC) V 1000 Series fuse.rating A 20 Power Tolerance Wp ±3% Measurement conditions:STC 1000 W/m'•AM 1.5•Temperature 25°C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty<-3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by±3%. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight 19.5kg±0.2kg 431bs±0.41bs Dimensions(H x L x D) 1762 mm x 1037 mm x 35 mm 69.4 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)* 5400 Pa rear load/5400 Pa front load 112.8 lb/ft2 rear load/112.8 lb/ft'front load Hail impact resistance 0 25 mm at 83 km/h 01 in at 51.6 mph Cells 120 Half cells-Si mono PERC 120 Half cells-Si mono PERC 9 busbar-83 x 166 mm 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM antireflective coating DSM antireflective coating Cables and connectors(refer to installation manual) 1350 mm,0 5.7mm,MC4 from Staubli 53.15 in,0 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-305Q045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient lsc +0.064%/°C Module product workmanship warranty 25 years** Temperature Coefficient Voc -0.28%/°C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.36%/°C >_97.1%end 1st yr NOCT(±2°C) 45°C 2_91.6%end 12th yr >_85.1%end 25thyr Operating temperature -40/+85°C z82.6%end 30th yr CERTIFICATIONS SHIPPING SPECS ULC ORD C1703,UL1703,CEC listed,UL 61215-1/-1-1/-2,UL 61730-1/-2, Modules Per Pallet: 26 or 26(California) Product IEC 61215-1/-1-1/-2***.IEC 61730-1/-2***,CSA C22.2461730-1/-2,IEC 62716 Ammonia Corrosion;IEC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 2 Pallets Per Truck 34 or32(California) Factory 1509001:2015 Modules Per Truck 884 or 832(California) * A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.com *** Certification in progress. PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads t L. 69.4"[1762mm] ION E v E in °I 14"[356mm] 41 3"[1050mm] 14"[356mm] �'• T +1888.781.7074 _ IONSOLAR.COM �, / Mounting Hole(x4) (-7, SILFAB SOLAR INC. [12mm] �� 800 Cornwall Ave Bellingham WA 98225 USA 7+1360.569.4733 'E" info@silfabsolar.com i E' E SIL FABSOLAR-COM E 1.4"[35mm] �o E M 1770 Port Drive A . i-i. to toN _ o BurlingtonWA98233USA m co T 1360.569.4733 ^N 0, O '. cwn IT 2 v 240 Courtneypark Drive East 3 1 0.06" 53.15" N c Mississauga ON L5T 2Y3 Canada --' [1.5mm] [1350mm] c T+1905.255.2501 = F+1905.696.0267 L3, n Cable Length ` 2 o Sitfab-SIL-380-HC-20211101 _,Drainage Hole(x8) CT tS1Noreproaucfonot any kind:aunwedwennnt '�] / permission Data and informations subject to . - + modifications without notice.©Sitfab Solar Inc., 2021.Sitfab Solar'"is a trademark of Saab solar Inc. L.. 2.4"[60mm] 8"[200mm]l IQ8 and IQ8+ Microinverters INPUT DATA(DCI 108-60-2-US IQ8PLUS-72-2-US Commonly used module pairings' W 235-350 235-440 Module compatibility 60 cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module Iscj A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA IACI I08-60-2-US I08PLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range3 V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.31 x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://link.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2022-03-17 CLICK BONDING AND GROUNDING 7.2 Grounding GROUNDING LUG INSTALL 1 2 3 4 �r x Install ground lug on the module per ground lug and module manufacturer's instructions NECESSARY COMPONENTS: On of the following ground lugs(or any UL 2703 compliant ground lug): • BurndyCL50-1TN Ground Lug(UL 2703-E3514343/UL467-E9999) • ILSCO SGB-4 Ground Lug(UL 2703- E354420 I UL 467-E3i1'1'10) • ILSCOGBL-40BT(UL2703- E354420 I UL467-E34440I • ILSCO GBL-4DBTH (UL 2703- E354420/UL 467-E34440) • ILSCO GBL-455(UL 2703- E354420 I UL 467-E34440) This system needs to be grounded in accordance with the National Electrical Code,ANSI/NFPA 70. *Copper wire should not come in direct contact with aluminum at any point on the array* 7.3 MLPE Clip Installation(Optional) INSTALL MLPE CLIP ACCESSORY • Determine mounting location of the MLPE and MLPE Clip on the module frame.Take care not to block drainage holes on the frame. • Push the nut/bolt of the MLPE Clip so the carriage bolt head is furthest away from the stainless plate. • Slide the bolt shaft into the slot on the MLPE mounting flange. • Place the assembly onto the module flange, MLPE mounting flange on the far face(upper side)of the - module frame flange,stainless plate on the closer face 7010 (bottom side)of the module frame flange. • Hold the carriage bolt into the MLPE mounting flange slot with your finger,this will keep the carriage bolt from x µ, spinning in the slot.Tighten the nut to 144 in-lbs using a 1/2"hex socket. MLPE CLIP IS COMPATIBLE WITH: • Enphase Products:M250-72,250-60,M215-60,C250-72,S230,S280,IQ 6,IQ 6+,IQ,IQ7,IQ 7A,IQ 7+,IQ 7X,Q Aggregator • SolarEdge Products:P300,P320,P340,P370,P400,P405,P485,P505, P600,P700,P730,P800p,P800s,P850,P860 • See page 21 for compatible module list with MLPE Clip 19 VERSION:2.0 REV DATE:07/16/2020 CLICK RATINGS Fire Rating** Class A System Fire Rating Max System Voltage 1500 VDC Max Fuse Rating 30A Certification Conforms to UL STD 2703 Warranty, 20 Year Material and Workmanship UL 2703 Markings Product listing label is located on the rail end-caps Roof Pitch' 2:12-12:12 UL 2703 Allowable Design Load Rating 10 psf downward,5 psf upward,and 5 psf lateral Max Module Size 24 soft Module Orientation: Portrait or Landscape **Class A System fire rating with Type 1&2 PV modules.Any module-to-roof gap is permitted,with no skirt required.This rating is applicable with any roof attachment. NOTE:Mid Clamp,MLPE Clip,and MLPE Bracket have been evaluated for multiple use,position independent. UL 2703 Marking Example: `°� EcoFasten' 10T1 SUEC • CLICKFIT SYSTEM Intertek t , MEG ID CODE:XXX-MM-YYYY 1234567 `' Con(onns to UL STD_>7U' Torque Specifications Component Torque(in-lb) Notes Lag Screw N/A Fully Seat.Use visual indicator of the black EPDM ring around the bonded washer for torquing. Mid-Clamp 144 End-Clamp 96 Rail Clicker Leveling Bolt 142 Pre-torqued upon delivery.Applies to Tile Hook and L-Foot/Clicker Hook Height Bolt N/A Lightly clamp hook to flush with top of next tile row Ground Lug N/A Refer to specific ground lug manufacturer's installation manual MLPE Clip 144 MLPE Mount 144 5 VERSION:2.0 REV DATE:07/16/2020 SolarPTL -a solar service company Date: 26 May 2020 Attn: Alex Morano Product Engineer •• • • EcoFasten Solar 4141 West Van Buren Street, Suite 2 Phoenix,AZ 85009 • Email:Alex.Morano@ecofasten.com Letter of Conformance - ClickFit UL 2703 Qualification Requirements Type of Equipment: PV Mounting System Model Designation: ClickFit Serial Number: N/A Test Requirement: ANSI/UL 2703: First Edition SolarPTL File Number: L3-ECF181228_R2 SolarPTL Project Number: ECF181228 Dear Alex, EcoFasten Solar's ClickFit mounting systems has been successfully evaluated for all applicable requirements of ANSI/UL 2703, when installed in accordance with the ClickFit Install Manual (ClickFit RAPID INSTALLATION, HIGH- QUALITY SOLAR MOUNTING SYSTEM FOR SHINGLE AND TILE ROOFS Rev 1.19.2020). The ClickFit PV mounting system was previously qualified under SolarPTL certificate number TU 722090002.01. Table 1:Qualified PV Modules Module Downward Pressure Upward Pressure Down-slope Qualified for Manufacturer Model Type Test Load(psf) Test Load(psf) Test Load(psf) Bonding Canadian Solar CS3K-P,CS3K-MS,CS6K-P,CS6K-MS X JKM xxx M-60B,JKM xxx M-60 JKM xxx M- 60-V,JKM xxx M-60HB Jinko JKM xxx M-60H,JKMxxxM-60L X JKMxxxM-6OHL,JKMxxxM-60BL,JKM xxx P-60B Heliene 60MXXX,60PXXX X LONGi LR6-60 Series X LG Electronics LGXXXN1C-V5,LGXXXN1K-V5, 15.0 7.5 7.5 X LGXXXQ1C-V5,LGXXXQ1K-V5 Q.PEAK-G4.1 XXX,Q.PEAK-G3 XXX Q.PEAK-G4 XXX,Q.PEAK BLK-G4 XXX Q CELLS Q.PEAK BLK-G4.1 XXX,Q.PLUS BFR- 30 30 7.5 X G4.1 XXX,Q.PEAK DUO BLK-G5 Q.PEAK DUO-G5 SIL-XXX NL Silfab SIL-XXX ML X SIL-XXX BL Yingli YL2XXP-29b,YLXXXM60 30b,YLXXXM- x VG 30b,YLXXXM-TI 30b This letter may be used as a letter of conformance(LOC)indicating the module series listed in Table 1 above,are qualified for use on the ClickFit PV mounting system.The above PV modules should be added to the ClickFit Installation Manuals.These newly qualified module series are in addition to the previously qualified module list found in Annex 2 of the ClickFit certification Test Report 319490011.001,issued by SolarPTL. Sincerely, Kamerine Kroner Division Manager—Mounting Systems SolarPTL,LLC SolarPTL,LLC 1107 W.Fairmont Drive Tempe,AZ 85282 480.966.1700 REVISION DATE:07/6/21 VERSION:v2.5 CLICK pea INSTALLATION GUIDE ° ° EcoFasten For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES ReneSola modules with 35,40 and 50 mm frames AAxxxY-ZZ Renesola Where"AA"can be SPM(SLP)orJC;"Y"can be blank, F,M or S;and"ZZ" can be blank,Ab,Ab-b,Abh,Abh-b,Abv,Abv-b,Bb,Bb-b,Bbh,Bbh-b,Bbv, Bbv-b,Db, Db-b,or 24/Bb Renogy Modules with 40 and 50 mm frames Renogy RNG-xxxY Where"xxx"is the module power rating;and"Y"can be D or P Risen Modules with 35 and 40 mm frames Risen RSMyy-6-xxxZZ Where"yy"can be 60,72, 120, 132 or 144;and"ZZ"can be M or P S-Energy modules with 35 and 40mm frames SABB-CCYYY-xxxZ S-Energy Where"A"can be C, L or N;"BB"can be blank,20,40 or 45;"CC"can be blank,60 or 72;"YYY"can be blank, MAE, MAI, MBE, MBI, MCE or MCI;and "Z"can be V, M-10, P-10 or P-15 Seraphim modules with 35 and 40 mm frames Seraphim SEG-aYY-xxxZZ Energy Group Where"a"can be blank,6 or B;"Yr can be blank,MA,MB, PA,or PB;and "ZZ"can be blank, BB,BG, BW,HV,WB,WW,BMB, BMA-HV,BMB-HV Seraphim modules with 35,40 and 50 mm frames SRP-xxx-YYY-ZZ Seraphim USA Where"xxx"is the module power rating;and"YYY"can be 6MA, 6MB,6PA, 6PB, BMD,6QA-XX-XX,and 6QB-XX-XX;ZZ is blank, BB or HV Sharp modules with 35 and 40 mm frames Sharp NUYYxxx Where"YY"can be SA or SC Silfab Modules with 35 and 38 mm frames SYY-Z-xxxAb Silfab Where"YY"can be IL,SA, LA,SG or LG;"Z"can be blank, M, P,or X;"A"can be blank, B, H, M, N;and"b"can be A,C, L,G, K,T, U or X Solaria modules with 40 mm frames Solaria PowerXT xxxY-ZZ Where"Y"can be R or C;and"ZZ"can be AC, BD,BX, BY, PD, PM, PM-AC, PX, PZ,WX or WZ Solarcity modules with 40 mm frames Solarcity SCxxxYY (Testa) PAGE Where"YY"can be blank, B1 or B2 2,6 Data Sheet Enphase Networking Enphase The Enphase IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell IQ Combiner 4/4C modem (included only with IQ Combiner 4C) X-IQ-AM1-240-4 consolidates interconnection equipment X-IQ-AM1-240-4C into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for -17 residential applications. It offers up to four '� 2-pole input circuits and Eaton BR series eENPHASE ! busbar assembly. Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05),included only with IQ Combiner4C • Includes solar shield to match Enphase IQ Battery ` aesthetics and deflect heat E:F • Flexible networking supports Wi-Fi, Ethernet,or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom,back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC • �E plug-in breakers(not included) • X-IQ-AM1-240-4C • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed i'12!° • LISTED X-IQ-AM1-240-4 E N P H AS E To learn more about Enphase offerings,visit enphase.com Enphase IQ Combiner 4/4C MODEL NUMBER IQ Combiner 4...X-IQ-AM1-240-4 .t.=.t.,._._,. Combiner ( ) I Q 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-p 5%)and consumption monitoring(+/-2.5i).Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C(X-IQ-AM1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Ensemble Communications Kit -Includes COMMS-KIT-01and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for COMMS-CELLMODEM-M1-06 Ensemble sites CELLMODEM-M1-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-AT-05 -4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. BRK-10A-2-240V Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support EPLC-01 Power line carrier(communication bridge pair),quantity-one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating 65 A Max.continuous current rating(input from PV/storage) 64 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers MECHANICAL DATA Dimensions W,�,._.., ., ( xHxD) 37.5 x 49.5 x 16.8 cm(14.75"x 19.5"x 6.63") Height is 21.06 (53.5 cm)with mounting brackets. Weight 7.5 kg(16.5 Ibs) Ambient temperature range -40°C to+46°C(-40°to 115°F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors • 60 A breaker branch input:4 to 1/0 AWG copper conductors • Main lug combined output:10 to 2/0 AWG copper conductors • Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude Up to 3000 meters(9,842 feet) INTERNET CONNECTION OPTIONS Integrated Wi Fi 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) COMPLIANCE Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1, 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 To learn more about Enphase offerings,visit enphase.com e EN P H AS E ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject to change_08-26-2022 ooa Eco Fasten For Installers. By Installers. COMPLETE RAIL- BASED RACKING SYSTEM NS AL _ AT ON DE REVISION DATE: 1 1/02/20 VERSION: v2.2 ECOFASTENSOLAR.COM TABLE OF CONTENTS Subject Page # Introduction 3 Product Description 4 Ratings 5 System Components 6 Required Tools 7 Array Layout 8 Installing ClickFit 9 Flashing and L feet 10 Installing Tile Hooks 11 Tile Hook Sub-Flashing 12 Installing the Rail 13 Module Installation 14 - 17 Bonding and Grounding 18 - 19 • MLPE Clip Installation 20 UL2703 Certified Modules 21-29 Clamp Tables 30 2 VERSION:2.2 REV DATE:11/2/2020 INTRODUCTION 1.0 Introduction This manual describes the installation of the ClickFit mounting system for photovoltaic modules on steep-slope roofs. Described within are details for composition shingle and tile,attachments for ClickFit System. Other roof types as well as all other installation manuals can be found for download at www.EcoFastenSolar,com. 2.0 General Installation Conditions 2.1 General Failure to observe the requirements in this document can lead to the exclusion of all guarantees and product liability. EcoFasten Solar reserves the right to amend this document without prior notice. 2.2 Stability and Condition of the Roof The roof must be in good condition and strong enough to support the weight of the modules, including the additional equipment,wind and snow loads.When in doubt, consult with the engineer of record,and/or the local building inspector. 2.3 Application Range of ClickFit • Refer to Compatibility module list on page 21. • Please refer to the Ecofasten ClickFit span tables for system structural certification and allowable spans. 2.4 Warranty Guarantee according to the warranty conditions and general terms and conditions of EcoFasten Solar.These conditions can be found on the website at www.EcoFastenSolar.com. 2.5 Liability EcoFasten Solar cannot accept any liability whatsoever for damage or injury caused by not taking adequate safety precautions or(accurately)following the instructions given, or resulting from negligence during the installation of the product and any corresponding accessories specified in this document. 3 VERSION:2.2 REV DATE:11/2/2020 CLICK PRODUCT DESCRIPTION The ClickFit mounting system consists of patented adjustable tile hooks and L feet, rails, and the installation materials required for the mounting of photovoltaic modules on composition shingle or tile roofs. For simplicity, tile hooks and L feet will be referred to as "attachments". 3.1 Attaching to the Roof The attachments are fastened to the rafters. Attachments are height-adjustable to level the system on uneven roof surfaces. 3.2 Attaching the Rail The rail assembles to the attachments with a click-connector, or Clicker. The rail simply clicks into place without the use of any tools. 3.3 Attaching the modules The modules are attached to the rails by means of mid clamps and end clamps. Installer must review module and any 3rd party manufacturer's documentation for compatibility and compliance with warranty terms and conditions 4 VERSION:2.2 REV DATE:11/2/2020 • RATINGS Fire Rating** ; ; Class A System Fire Rating Max System Voltage 1500 VDC Max Fuse Rating 30A Certification Conforms to UL STD 2703 Warranty 20 Year Material and Workmanship UL 2703 Markings Product listing label is located on the rail end-caps Roof Pitch �; 2# ;12 6 _ _ _ UL 2703 Allowable Design Load Rating 10 psf downward,5 psf upward,and 5 psf lateral Max Module SIze • . s Module Orientation Portrait or Landscape Multiple use Rated components(Position Independent) Mid Clamp,MLPE Clip,and MLPE Bracket` **Class A System fire rating with Type 1&2 PV modules.Any module-to-roof gap is permitted,with no skirt required.This rating is applicable with any roof attachment. UL 2703 Marking Example: oCl' EcoFasten ESDEC I V us CLICKFIT Intertek n SYSTEM MFG ID CODE:SSS-QQ-YYYY XXXXXXX Cn rforrnsto 3 51D_'7L`� Torque Specifications Component Torque(in-lb) Notes Lag Screw N/A Fully Seat.Use visualindicator of the black EPDM ring around the bonded washer forttrquinp _. Mid-Clamp 144 End-Clamp - _ 96 Rail Clicker Leveling Bolt 142 Pre-torqued upon delivery.Applies to Tile Hook and L-Foot/Clicker Hook Height Bolt N/A Lightly clamp hook to`:flushWith top of next tile'row Ground Lug N/A Refer to specific ground lug manufacturer's installation manual MLPE Clip 1 MLPE Mount 144 5 VERSION:2.2 REV DATE:11/2/2020 CLICK SYSTEM COMPONENTS ______ 1) ClickFit Rail 1500033 (2130mm) -�� 1500034 (3166mm) - �__ 1500035 (4202mm) // --r 2) Rail Splice ��', °°/ 1008061 0, �0,_ ��v lA �j �i 3) CF Tile Hook and L foot c c „ v° — 1% 1500005-Tile Hook oe' oe -'�� I 1500004-L foot eP 1! f e4) CF End Clamp "l" Section 10 'o See '�/ 5 CF End Cap /� 1510041 (Black) % ,., 1510042 (Grey) 6) CF Mid Clamp See Section 10 7) MLPE Mount 1510057 I' L 9, C�- --'` - ` 8) MLPE Clip (Rocklt Clip 2.0) �%� 9) Module Jumper -� 1500028 6 VERSION:2.2 REV DATE:11/2/2020 REQUIRED TOOLS Checklist of tools and accessories Note: *Proper PPE shall be worn at all times* Tape measure Roof crayon or chalk(a chalk line can be helpful as well) •1 P Cordless drill with torque adjustment and the following bits: • 1/2"Hex socket • 1/4"diameter drill bit. (Drilling length no less than lag bolt depth) Brush for clearing debris from roof surface. Hint: Leaf blowers work well to remove any leftover moisture prior to installation. Torque wrench capable of 0-150 in-lbs 7 VERSION:2.2 REV DATE:11/2/2020 CLICK ARRAY LAYOUT • Refer to span tables, local jurisdiction, or engineer of record specifications when determining setbacks from roof edges, attachment spans, etc. • Mark the perimeter and corners of the array on the roof surface. *Add 3/4"to account for the gap between modules in each direction* • Draw or snap chalk lines where the rails will be installed,(refer to module manufacturer specs to determine allowable mounting locations). • Locate rafters within the area of the array. It may be necessary to shift the array East or West on the roof in order to fall within the rail cantilever specs(1/3)of span). • Stagger rafters every row if required by the local jurisdiction, engineer of record, or company policy. `� 1 _ ///11 / VERSION:2.2 REV DATE:11/2/2020 MEMO INSTALLING CLICKFIT Pre-installing rail splices 1. Determine the number of rails required per row of modules. 2. Insert a rail splice into one rail. *Do not push it past the center bump.* 3. Slide the next rail onto the rail splice until the two rail ends meet. 4. Repeat steps 2 and 3 until the desired length is achieved. *This is usually easiest to do from the ground.* Olt 0 (.....,_ _ do _ ,,,,eP-1-1 * - ilIP :,-, c--------'t r _. ,,,,,,....,......_ ..._______// !,,,,,..,.:1 ,' _.— VERSION:2.2 REV DATE:11/2/2020 =3M FLASHING AND L FEET Installation of flashing and L feet • ClickFit for comp shingle roofs uses EcoFasten Solar's GFI watertight flashing system • Other roof types may use different EcoFasten Solar attachments,see www.EcoFastenSolar.com for more information. Installation Steps: 1. Locate rafter lines from section 5.2. 2. Drill 1/4"pilot holes at all attachment points and back fill using roof-compatible sealant. 3. Separate shingles where flashing is to be installed. Insert the flashing so the top portion is under the next row of shingles North. Ensure the flashing is pushed to the third-course of shingle to prevent water infiltration through the vertical joints between shingles. 4. Align GFI flashing hole with pilot hole. Insert the lag bolt with pre-installed bonded washer through the L foot and EPDM grommet.Tighten the lag bolt until a ring of EPDM is visible around the circumference of the bonded washer. Tighten the lag until fully seated.The EPDM Ring visual indicator is the most effective way to ensure a watertight seal. 1 2 3 `Note the orientation of the L foot and Clicker.The two Clicker"arms"should be facing downslope* 10 VERSION:2.2 REV DATE:11/2/2020 . . 03311, INSTALLING TILE HOOKS 1. Locate rafters on the roof, mark the tiles to be removed. Hint: In some cases rafter tails are visible at the - eaves of the roof, making it easy to find the rough location of the rafters. In other cases,the fascia board may have nail heads visible where it was attached to the rafters. In the worst-case a row of tiles may need to be moved to determine the rafter locations. • 2. Slide the tile at the desired location upward to expose the roof sub surface. If the tile is to be notched, or if using a replacement flashing, remove it entirely. Clean the sub surface with a brush to remove any debris that could affect the sealing. 3. Locate the rafter center and mark it. 4. Place the tile hook with the hook itself in the valley of the next tile below. Drill one 1/4"pilot hole in the rafter center,taking care to keep the hook in the valley of the tile below. Backfill this hole with a roof- compatible sealant. For flat tiles,try to avoid having the hook land directly under a joint between tiles, this will create a larger gap or more notching than necessary. 5. Install one 5/16"x 4"lag screw on the row of holes closest to the tile hook arm. If possible, install the screw in one of the three holes directly next to the arm. If the lag screw must be installed in one of the seven holes furthest from the arm (denoted by the red rectangle below), install three deck screws in the pattern shown by the green circles below. 6. Adjust the height of the tile hook as necessary using the bolt shown in the fourth image. 7. Flash the surrounding area and lag screw head with roof-compatible sealant as necessary. Refer to Tile Hook Subflashing Installation guide on the next page. 8. Replace the tile that was moved and/or removed, or install the tile replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding wheel or by using a chisel. • _5r'� v OOOOOOOOQO 000000• • ...V ' . *.**7: A .. /- \ . ... 6. 100 /// \ ...\ sM VERSION:2.2 REV DATE:11/2/2020 CLICK TILE HOOK SUB-FLASHING CLICKFIT TILE HOOK SUB-FLASHING INSTALLATION STEPS: Tools Required:Caulking gun,roofing mastic applicator Materials Required:Roofing mastic,reinforcing fabric, roof sealant ,i :‘ ,., xkM1� Apply a continuous line of the roofing Lower the sub flashing over the the hook base. It may manufacturer's approved sealant on the be necessary to move adjacent tiles to easily lower the underside of the ClickFit tile hook sub-flashing sub-flashing onto the roof deck to form a U-shape around the raised edges. EcoFasten recommends following the TRI guidelines Place the sub-flashing over the base of the tile hook so three course sealing method.Start the three course the flashing covers the entire base. sealing method by applying a layer of roofing mastic over the edges of the tile hook sub-flashing. m* ^ y,N Place strips of reinforcing fabric over mastic to Apply a final layer of mastic to completely cover cover approximately 2"from the edge of the the reinforcing fabric.The flashing is now installed sub-flashing in both directions. Place strips on and sealed. the side first,then the top edge. 12 VERSION:2.2 REV DATE:11/2/2020 KEE= INSTALLING THE RAIL 1. Place the rail in the Clickers. 2. Ensure the rails extend a minimum of 2"past the last attachments in each row and that each rail is aligned with the next row North and/or South. 3. Roll the rail into each Clicker,an audible"click"should be heard. If attachments are extremely misaligned - it may be necessary to loosen the leveling bolt, snap the Clicker onto the rail,then re-tighten the leveling bolt to 142 in-lbs. 4. Level the rail if necessary by loosening the bolt attaching the Clicker to the L foot or tile hook. 7----11.1.-7) ll oril& II \<"--"1 La 40.1.414,„ k -- k ass *Ensure the tab on the Clicker is aligned with the rail edge as shown below* ---(---- ........, , „ )'. , _ _L--- „_1 _,_ ___________________ w_- 13 VERSION:2.2 REV DATE:11/2/2020 CLICK MODULE INSTALLATION 1. Install the end clamps on each rail on whatever end you are starting with. • Snap the end clamp onto the rail. • Slide the end cap onto the rail. _ • Turn the leg of the end clamp around the cap. r .ram 4,, •6,41 I t t aki0. 2. Place the module on the rail. *Ensure module junction box is up-slope.* �r v�� 0, <4......, 3. Slide the module to the end clamp and align it with the array corners.Tighten the end � `,` - clamp to 96 in-lb. ,r, 14 VERSION:2.2 REV DATE:11/2/2020 "Mg MODULE INSTALLATION 6.6 Installing additional modules on the rail • 407, 1. Click a mid clamp onto each rail. 2. Slide the mid clamps until they are flush with the side of the existing module. 1� \ 3. Place and slide the next module firmly against the mid clamps.Align the bottom edges of the modules.Tighten mid clamps to 144 in-lb. 4 15 VERSION:2.2 REV DATE:11/2/2020 MODULE INSTALLATION 6.7 INSTALLING END CLAMPS AT THE END OF A ROW 1. Install the last mid clamps in the row. 2. Measure the rails from the last mid clamp to the module width plus I". 3. Cut the rails at this mark.There is some adjustment in the end cap/clamp so it does not need to be a perfect cut. 4. Install end clamps and end caps,tighten to 96 in-lb Alternative method: 1. Install the last module in the row,tighten the mid clamps. 2. Using a circular saw with a metal blade, or carefully with a reciprocating saw, cut the rail approximately I"past the edge of the last module. 3. Install end clamps and end caps,tighten to 96 in-lb i r J/ , 16 VERSION:2.2 REV DATE:11/2/2020 CLICK MODULE INSTALLATION 6.8 Installing additional rows of modules 1. Place the first module of the next row against the end clamps. 2. Temporarily place a mid clamp in the N-S gap between rows of modules, slide the modules up to the mid clamp as shown below. 3. Once the modules are aligned tighten the end clamps. 4. Install Dynobond clip on the bottom lip of the module frames to bond rows together. 5. Repeat steps 6.5-6.7 until the array is complete. 17 VERSION:2.2 REV DATE:11/2/2020 BONDING AND GROUNDING Bonding Paths All bond paths are carried either module-to-module through the mid clamp, or module-to-module through the module jumper shown below(bond paths shown in green): CF Mid Clamp Module Jumper 2 mid clamps bonding �j pairs o modules _ - 1 module jumper _ - - bondi g row to row 1 ground lug per continuous array Rail Spice �% lid Y�!�i� �►' 1 splice bonding adjacent pairs of rails 18 VERSION:2.2 REV DATE:11/2/2020 CLICK BONDING AND GROUNDING 7.2 Grounding GROUNDING LUG INSTALL 1 2 3 4 • s Install ground lug on the module per ground lug and module manufacturer's instructions NECESSARY COMPONENTS: On of the following ground lugs(or any UL 2703 compliant ground lug): • BurndyCL50-1TN Ground Lug(UL 2703 - E3514343/UL 467-E9999) • ILSCO SGB-4 Ground Lug(UL 2703- E354420 I UL 467- E34440) • ILSCOGBL-40BT(UL2703 -E354420 I UL467- E344401 • ILSCO GBL-4DBTH (UL 2703- E354420/ UL 467- E34440) • ILSCO GBL-455(UL 2703-E354420 I UL 467-E34440) This system needs to be grounded in accordance with the National Electrical Code,ANSI/NFPA 70. *Copper wire should not come in direct contact with aluminum at any point on the array* 7.3 Rocklt Clip 2.0 Installation (Optional) INSTALL ROCKIT CLIP 2.0 ACCESSORY �; . • Determine mounting location of the MLPE and Rocklt Clip 2.0 on the module frame.Take care not to block drainage holes on the frame. • Push the nut/bolt of the Rocklt Clip 2.0 so the carriage bolt head is furthest away from the stainless plate. • Slide the bolt shaft into the slot on the MLPE mounting t flange. • Place the assembly onto the module flange, MLPE • mounting flange on the far face(upper side)of the module frame flange, stainless plate on the closer face 7Aur'` (bottom side)of the module frame flange. ," • Hold the carriage bolt into the MLPE mounting flange slot with your finger,this will keep the carriage bolt from spinning in the slot.Tighten the nut to 144 in-lbs using a 1/2"hex socket. ROCKIT CLIP 2.0 IS COMPATIBLE WITH: • Enphase Products:M250-72,250-60,M215-60,C250-72,S230,S280,IQ 6,IQ 6+,IQ,IQ7,IQ 7A,IQ 7+,IQ 7X,Q Aggregator • SolarEdge Products:P300,P320,P340,P370,P400,P405,P485,P505, P600,P700,P730,P800p,P800s,P850,P860 • See page 21 for compatible module list with MLPE Clip 19 VERSION:2.2 REV DATE:11/2/2020 CLICK MLPE MOUNT INTALLATION _ _ \ 7** I Iii Lower the MLPE Mount to the rail Tilt and hook the mount around the top"dog ear of the rail rf.L..jj \ Mali 1 Set the MLPE Mount flush with the top of the rail Slide the microinverter flange between the MLPE Mount and the serrated bolt flange NM Tighten the bolt to 144 in-Ibs Repeat this process for all other microinverter and/or optimizer installations MLPE MOUNT IS COMPATIBLE WITH: Enphase Products: M250-72,250-60, M215-60,C250-72,S230,S280,IQ 6, IQ 6+, IQ, IQ7, IQ 7A, IQ 7+, IQ 7X,Q Aggregator SolarEdge Products: P300, P320, P340, P370, P400,P405, P485, P505, P600, P700,P730, P800p, P800s, P850, P860 20 VERSION:2.2 REV DATE:11/2/2020 MEP WIRE CLIP INSTALLATION 1 •a- 3 a With the ClickFit Rail in III lace and the Wire Clip in hand, place the wire end on either side of the 2 • _ rail. With the wire end (� touching the bottom lip '.\. of the rail, roll and click- in the Wire Clip to the opposite end of the rail. 3. - A You will hear an audible click when the Wire Clip ' iis set in place. 4 i 1 J 21 VERSION:2.2 REV DATE:11/2/2020 • UL2703 CERTIFIED MODULES 8.2 COMPATIBLE MODULE LIST This racking system may be used to ground and/or mount a PV module complying with UL 1703 or UL 61730 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted,"xxx" refers to the module power rating and both black and silver frames are included in the certification. MANUFACTURER LIST OF UL2703 APPROVED MODULES Adana r odule ith 35 and 40mmNframes t ASX-Y-ZZ-xxx Adam Where"X"can be M"Or.P,"Y"can be 6 or 7, and"ZZ"can be blank, PER C,. B-PERC, 5r AB-PERK Amerisolar modules with 35,40 and 50 mm frames AS-bYxxxZ Amerisolar Where"b"can be 5 or 6;"Y"can be M, P, M27, P27, M30,or P30; and"Z"can be blank,W or WB Aptos:modules with 35 and 40 mm;frames Aptos`Solar DNA-yy-zz23 x : n Where"yY�'can be 120:,or 144;and"zz"can be MF r Bi Astronergy modules with 30,35,40, and 45 mm frames aaS M bbyyC/zz-xxx Astronergy Solar Where"aa"can be CH or A;"bb"can be 60, 66, or 72;"yy"can be blank, 10 or 12;"C"can M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and "zz"can be blank, HV, F-B, or F-BH ASUN modules with 35.and 40 mm frames ASU i ASU Nxxx-YYZZ-aa Where"YY"can be 60 or 72;"ZZ can be M,or MH5; and"aa" can:be blank or BBB Auxin modules with 40 mm frames Auxin AXN6y6zAxxx Where"y"can be M or P;"z"can be 08, 09, 10, 11, or 12; and"A"can be For Axitec Modules with 35;arid 40 mr6 frame • AC x xY/aaZZb AxiteC Where"Y"can be.M, P or MH;"aa"can be blank, 125 or'156-;"ZZ"can lie 54, 60,72, 120,or 144;"b"can be 5,X,`V,XV, or MX 22 VERSION:2.2 REV DATE:11/2/2020 CLICK UL2703 CERTIFIED MODULES MANUFACTURER LIST OF UL2703 APPROVED MODULES • Boviet modules with 35 and 40mm frames Boviet BVM66aaYY-xxxBB Where"aa"can be 9, 10 or 12;"YY"is M or P; and"BB"can be blank or L BYD modules with 35 rim.frames BYD Where"A"can be M6, P6,,MH or PH; "Y"can be C or K;and"ZZ"can be 30 or 36 Canadian Solar modules with 30,35 and 40 mm frames Canadian Solar CSbY-xxxZ Where"b"can be 1, 3 or 6;"Y"can be H, K, P, U,V,W, or X; and"Z"can be M, P, MS, PX, M-SD, P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD CertainTeed modules with 35 a id 40 frames. CTxxxYZZ-AA CertainTeed Where"Y"can be M, P,or HC;"ZZ"can be 00,01, 10,or 11; and"AA"can be 01, 02,03,or 04 Csun modules with 35 and 40 mm frames CSUN YYxxx-zzAbb Where"YY"is CSUN or SST;"zz"is blank, 60,or 72; and"A"is blank, P or M; "bb"is blank, BB, BW, or ROOF Dehui modules with 35 and 40mm frames Dehui DH-MYYYZ-xxx Where"YYY"can be 760,772,860, 872; and"Z"can be B or W Ecosolargy modules with 35,40,and 50 mm frames ECOxxxYzzA-bbD Ecosolargy Where"Y"can be A, H, S, or T;"zz"can be 125 or 156;"A"can be M or P;"bb" can be 60 or 72; and"D"can be blank or B ET Solar modules with 35,40,and 50 mm:frames E�Solar ET-Y6ZZxxxAA Where"Y"can be P, L,or M."ZZ"can be 60 or 72; and"AA"can be WE3,WW,. BB,.WBG,WWG,WBAC,WBCO,WWCO,WWBCO or BBAC Flex modules with 35,40,and 50 mm frames Flex FXS-xxxYY-ZZ; Where"YY"can be BB or BC; and"ZZ"can be MAA1 B, MAA1W, MAB1 W, SAA1 B, SAA1W, SAC1 B,SAC1W, SAD1W,SBA1 B, SBA1W, SBC1 B, or SBC1W 23 VERSION:2.2 REV DATE:11/2/2020 CLICK UL2703 CERTIFIED MODULES _ MANUFACTURER LIST OF UL2703 APPROVED MODULES r GCL modules withi.35 m and 40 mni'frames GCL-ab/YY xxx • GCL _.r II II ) 7Y , Where a can be M or P;x b can be.3 or 6; and"YY"can be 60,72,"721 or 72DH ;, Gigawatt modules with 40 mm frames GigaWatt Solar GWxxxYY Where"YY"can be either PB or MB H nsol modules with 35 and 40 frames Hr"illlfsol r HS xxx YY:zz Where"YY"can be PB,PD, PE,TB,TD, UB,UD, or UE;and"}zz"can be AH2, -AN1,AN3,AN4, HV1,orJHZ Hanwha Solar modules with 40,45, and 50 mm frames Hanwha Solar HSLaaP6-YY-1-xxxZ Where"aa"can be either 60 or 72;"YY"can be PA or PB; and"Z"can be blank or B Hanwha Q CELLS'Modules with„c32,:35,40, and 42mm frames ' aaYY-ZZ xxx , . where"aa"Vcan be Q.or ,"YY"can be.``PLUS, PRO,PEAK, LINE PRO, LINE r PLUS, PLUS DUO or PEAK DUO;and"ZZ"'can be G3`G3.1,G4,:G4.1, L-G2, L-G2.3, L-G3, L-G3 1,L Gay,L-G4, L-G4.2,L-G4y,,LG4.2/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BE t-G4,BFR G4.1, BFR G4 , BLK-G4.1, G4/SC,.G4.1/ . : Hanwha Q CELLS SC, G4.1/TAA,G4.1/ 'IA , BFR G4 1/TAA, BFR G411MAX, BLK G4.:1/TAA, BLK G4.1/SC, EC G4 4,x 5, G5/SC;G / B TS LK G5,:$ B LK-G5/SC,° LK G5/TS, L G5, L G'5.1, L-G5 2,L G5 2/H, L G5 3,GG6,G6/SC,G6/TS, G6+,BLK-G6, L-G6, L G 1:,L-G6 2,L.G6.3, G7, BLK + BLK G6+/AC, BLK G6+/SC;BLK-G6/TS, G6+/TS, BLK-G6+/TS, BLK-G7,'G7 2,G8, BLK GB, G8+;BLK-G8+L-G7,L-G7.1, L G7.2;'L-G7.3, L-G8, L-G8 1,.L-G8.2, L-G83, L-G8.3/BFF, ML'-G9, BLK ML-G9,. MLG9+, BLK ML-G9+,XL-G9.2 or XL-G9 3 Heliene modules with 40 mm frames Heliene YYZZxxxA Where"YY"can be 36, 60, 72, or 96;"ZZ"can be M, P, or MBLK; and"A"can be blank, HomePV, or Bifacial HT-SAAE modules.wit•h 35 and,:40 m min frames HTyy 156Z-xxx HT-SAAE Where"yy"can be 601 r 72,"Z"c n e M, P. NI C,P C,M(S), "i(VS},M(V), t'(V), 24 VERSION:2.2 REV DATE:11/2/2020 IMMO UL2703 CERTIFIED MODULES MANUFACTURER LIST OF UL2703 APPROVED MODULES • Hyundai modules with 33,35,40 and 50 mm frames HiY-SxxxZZ Hyundai Where"Y"can be A, D, M or S; and"ZZ"can be HG, HI, KI, MI, ME, MG, RI, RG, RG(BF), RG(BK),SG,TI, or TG Itek.Modules with 40 and}50 mm frames Itek lT-xxx-YY Where"YY' can:be blank, HE,or ) ,or SE72 JA Solar modules with 30, 35,40 and 45 mm frames JAyyzz-bbww-xxx/aa JA Solar Where"yy"can be M, P, M6 or P6;"zz"can be blank,(K),(L), (R),(V), (BK),(FA), (TG),(FA)(R), (L)(BK), (L)(TG),(R)(BK), (R)(TG), (V)(BK),(BK)(TG), or(L)(BK)(TG); "bb"can be 48, 60, or 72;"ww"can be D09, S01, S02, S03, S06, S09, S10, or S12; and"aa"can be BP, MP, SI, SC, PR,3BB,4BB,4BB/RE, 5BB Jinko modules with 35 and 40 rim frames J KMYxxxZZ-aa Where"Y"can either be blank or S;"ZZ"can be M, P,or''PP;and"aa"'can be �1111C0 plank, 60,;60.B,60H,;60L,6OB , 60Ht_,t60HB,60HBL,6HBL-EP,v60 J4,60B J4 60B-EP, 60(Plus),60-V, 60-MX,72,72B,72 J4,72B-J4,72(Plus),72-V,72H-V, 720V,72HL-V,72-MX,,72H-BDVP,72HL-TV, or 72HL-V-MX3 Kyocera Modules with 46mm frames KYxxxZZ-AA Kyocera Where"Y"can be D or U;"ZZ"can be blank, GX, or SX; and"AA"can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 3BC, 3FC,4AC,4BC,4FC, 4UC, 5AC, SBC, 5FC, 5UC, 6BC, 6FC, 8BC, 6MCA,or 6MPA LG modules with 35,40,;and:46 mm frames LAG LGxxxYaZ-bb Where"Y"can be A,E, N, Q,.5;"a"can be 1,ur 2;"Z"can be C, K,T, or W;and "bb"can be A3,A5,B3,G3, 4,J5, K4, L5, N5, or V5 Longi modules with 30,35 and 40 mm frames L Ra-YYZZ-xxx M Longi Where"a"can be 4 or 6;"YY"can be blank, 60 or 72; and"ZZ"can be blank, BK, BP, HV, PB, PE, PH, HBD, HIB, HIH, HPB, HPH, or HIBD Mission Solar modules with 33 and 40 mm frames MSEbbxxxZZaa r Mission Solar . Where"bb"can be blank or-60A;"ZZ"-can be blannk,MM,SE,SO, SQ,SR, r TS;and"aa"can be blank, 1 J,4J,4S,5)K, 5T,60,6J,65, 6W,8K, 8T,or 95 25 VERSION:2.2 REV DATE:11/2/2020 UL2703 CERTIFIED MODULES MANUFACTURER LIST OF UL2703 APPROVED MODULES Mitsubishi modules with 46 mm frames Mitsubishi PV-MYYxxxZZ Where"YY"can be LE or JE; and"ZZ"can be either HD, HD2, or FB Motech fIM and XS series:modules with 40,45,and 50 mmfranies Next Energy Alliance modules with 35 and 40mm frames Next Energy yyNEA-xxxZZ Alliance where"yy"can be blank or US;"ZZ"can be M, MB or M-60 wr, Neo Solar Power nodules with 3S nm frames D6YxxxZZaa Nee Solar Power Where"Y."can be M or P,"ZZ can be3A,'B4A,F3A,E4A, H3A,H4A and"aa„ can be blank,.v TF),fME or ME(fil=) Panasonic modules with 35 and 40 mm frames V B H NxxxYYzzA Panasonic Where"YY"can be either KA, RA, SA or ZA;"zz"can be either 01, 02, 03,04, 06, 06B, 11, 116, 15, 15B, 16, 16B, 17, or 18; and"A"can be blank E, G or N =Peimar Modules with 40 mm frame SbxxxYzz. Where"b"can:be G,;M:or P; 'Y"can be M or P; and:"ie can be blank,(BF),or;, (FB) Philadelphia modules with 35 and 40 mm frames Philadelphia Solar PS-YzzM-xxx Where"Y"can be M or P;"zz"can be 60 or 72; and"AA"can be blank or(BF) Phono Solar modules with 35,40,and 45 mm frames PSxxxY-ZZ/A Phono Solar Where;"Y„can be M,Ml, MH, or M1 H or P; "ZZ"can be 20 or 24;and:"A„can be F,T,.U, orTH Recom modules with 35 and 40 mm frames Recom RCM-xxx-6yy Where"yy"can be MA, MB, ME or MF REC modules with 30,38and`45 mm frames' RECxxxYYZZ REC Solar Where"YY"can be AA, M NIP, PE, PE72,TP,TP2,TP2M,TP2SM,TP2S, or TPrv3M, and ZZ can be blank, Black,:BLK,.BLK2,SLV or 72 26 VERSION:2.2 REV DATE:11/2/2020 111EMIP UL2703 CERTIFIED MODULES MANUFACTURER LIST OF UL2703 APPROVED MODULES • ReneSola modules with 35,40 and 50 mm frames AAxxxY-ZZ Renesola Where"AA"can be SPM(SLP)or JC;"Y"can be blank, F, M or S; and"ZZ" can be blank,Ab,Ab-b,Abh,Abh-b,Abv,Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb Renogy.Modules with 40.and 50 rnrri frames; Renogy RNG-xxxY Where"xxx"is the module power rating;and"Y"can be D or P Risen Modules with 35 and 40 mm frames Risen RSMyy-6-xxxZZ Where"yy"can be 60, 72, 120, 132 or 144;and"ZZ"can be M or P ;:S-Energy modules with 40 frames S-Energy SNxxxY-ZZ Where"Y"can be M or P; and"ZZ"can be 1 0 'or 15' Seraphim modules with 35 and .a ...., nd 40 mm frames Seraphim Energy SEG-aYY-xxxZZ Group Where"a"can be blank, 6 or B;"YY"can be blank, MA, MB, PA,or PB; and "ZZ"can be blank, BB, BG, BW, HV,WB,WW, BMB, BMB-HV Seraphim modules with 40 and: 0 mm frames SRP-xxx-6YY-ZZ Seraphim USA P, Where"xxx"is the module power rating;and"YY"can be MA,MB, PA, PB, QA-XX-XX,and QB-XX-XX;Z is blank,Bor HV Sharp modules with 35 and 40 mm frames Sharp NUYYxxx Where"YY"can be SA or SC Silfab Modules'with.38 mm frames SYY-Z-xxxAb Slfab Where"YY"can be IL,SA, LA,`SG or LC, 'Z"can be blank, M;P,or X "A"..can be blank, B, H,M, N; and"b' can be A, L,G,or T. Solaria modules with 40 mm frames PowerXT xxxY-ZZ Solaria Where"Y"can be R or C; and"ZZ"can be AC, BD, BX, BY, PD, PM, PM-AC, PX, PZ,WXorWZ Solarcity modules with 40 mm frames Soarcity(Teslai: SCxxxYY Where"YY"can be blank, B1 orB2 27 VERSION:2.2 REV DATE:11/2/2020 UL2703 CERTIFIED MODULES MANUFACTURER LIST OF UL2703 APPROVED MODULES SolarTech modules with 42 mm frames SolarTech STU-xxxYY Where"YY"can be PERC or HJT ,SolarWorld Sunmodule Plus, Protect, Bisun, L.Bisun XL may be followed SolarWOrld AG by mono,poly, duo,black, b rn k, or clear; odules with 31,33 or 46 mm frames SW-xxx SolarWorld Sunmodule Plus, Protect, Bisun,XL, Bisun XL, may be followed SolarWorld Ameri- by mono, poly, duo, black, bk, or clear; modules with 33 mm frames cas SWA-xxx Sonali Modules,with 40 mm frames $onali SSxxx Stion Thin film modules with 35 mm frames Stion STO-xxx or STO-xxxA SunEdison Modules with 5;40&50 mm frames SE-YxxxZABC[7I SunEdistlil : , Where"Y"can be B, F, Ft, P, R,or Z,'"Z"can be C or 4;"A"can Pe B,C,D,E,H;1,- J,K,L M,or N ,•"B"can be B or.,..W;'"C"can be A or C;:'"D"can be 3, 7,8,or 9; and."E"can be 0; 1 or 2 Suniva modules with 35,38,40,46,and 50 mm frames O PTxxx-AA-B-YYY-Z Suniva MVXxxx-AA-B-YYY-Z Where"AA"is either 60 or 72;"B"is either 4 or 5;"YYY"is either 100,101,700,1 B0, or 1 B1; and"Z"is blank or B Sunpower,standard(G3:or G4)or InvisiMount(G5)40 and 46 mm frames SPR-Zb-xxx-YY Sunpower Where"Z"is either A, E,P or X;"b"can be blank,'I7, 18, 19,20,21, or 22;,and "YY"can be blank, BLK,COM, C-AC,D-AC, E-AC,G AC, BLK-C-AC,or BLK-D-AC Sunspark modules with 40 mm frames Sunspark SYY-xxxZ Where"YY"can be MX or ST; and"Z"can be M, MB, P or W Suntech Modules with 35i,40 and s50mm frames Suntech STPxxxy-zziaa where"y"is blank or S,and"zz"can be 20,24; and"aa"can be Vd,r em,Vfw, Wdb,Wde 28 VERSION:2.2 REV DATE:11/2/2020 EMS. UL2703 CERTIFIED MODULES MANUFACTURER LIST OF UL2703 APPROVED MODULES Talesun modules with 35 and 40 frames Talesun TP6yZZaaxxx-b Where"yy"can be blank, F or H;"ZZ"can be 60 or 72;"aa"can be M or P; and"b"can be blank, B,T, or(H) Trina`Modules with 30,35,40 and.46mm frames TSM-xxx1ZZ Where"YY"can be.DD05, DD06, DD14, DE14, DE15, DEG15, PA05, PC05, ,Trina PDO5, PDO6, PA14,PC14, PD 4 PE14,or PE15,and"ZZ"can be blank, .05, .08, .10, 18, .08D, .18D,0.82, ,002, .005,055,085,A,A.05,A.08,A.16,A;.1.8;`` A(II),A.05(11),A.08(11),A.082(II),A 10(II),A.18(li), H, H(II), H.05(ll), H.08(II), AC.20.(ll), HC 20(rl.l) M, M(11), M.05(4MC 20(J„I) URE modules with 35 mm frames URE DyZxxxHaa Where"y"can be 6 or 7;"Z"can be K or M; and"aa"can be H3A, H4A, or H8A Vikram solar modules with540 mm frames Vikram . VSyy.ZZ.AAA.bb Where:"yy"can be M, P, MBB, MH,.'MS, MHBB,or PBB;"ZZ"can'be 60 or 72; "AAA"isthe module power rating;and"bb"can be 03.04 or US VSUN modules with 35 and 40 mm frames VSUN VSUNxxx-YYz-aa Where"YY"can be 60, 72, 120, or 144;"z"can be M, P, MH, PH, or BMH; and "aa"can be blank, BB, or DG Waaree modules with 40rrim frames' Waaree WSyy-xxx where"yy"Can be blank, Mxor MB Winaico modules with 35 and 40 mm frames Winaico Wsy-xxxZa Where"y"can be either P or T;"Z"can be either M, P, or MX; and"a"can be blank or 6 w. Yingli Panda,YGE,YG E-U,and' seri 'se modules with 35,40,and 50 ni*frames ZNShine Modules with 30,35, and 40mm frames ZNShine ZXy6-ZZaa-xxx/b Where"y"can be M or P;"ZZ"can be blank, H, HLD, HLDD, LD, LDD, NH, NHLD or NHLDD;"aa"can be 60, 72, 120 or 144; and"b"can be M or P 29 VERSION:2.2 REV DATE:11/2/2020 ES1231110 CLAMP TABLES Frame Thickness Article Number 30 mm 1510015 32 mm 1510016 35 mm 1510017 38 mm 1510018 40 mm 1510019 45 mm 1510020 50 mm 1510021 Frame Thickness Article Number 30-40 mm 1510011 40-50 mm 1510012 INSTALLER RESPONSIBILITIES Periodic reinspection of components shall be performed to verify that there is no corrosion detrimental to system strength and electrical conductivity, no loose bolts,and/or other variables that could compromise array safety.Any corroded or damaged components shall be immediately replaced. 30 VERSION:2.2 REV DATE:11/2/2020