Loading...
Permit 111202S-0012.1 REC .'T City of Tigard A P R I 2 Building Division 13125 SW Hall Blvd,Tigard, OR 97223 BUILDINGYOF TIC -; 1.) Phone: 503.718.2439 Fax: 503.598.1960 DI 1.) T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14358 SW Hall Blvd City: Tigard Zip: 97224 Owner's Name: Scott Davey Date: 4/7/2023 Contractor's Name: ION DEVELOPER LLC CCB #: 230394 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation [I] Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? X❑ No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑X Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for above ElYes the prescriptive path. ❑ No 1 I:Building/Forms/Photovoltaic-Checklist02-01-11.docx Is the construction Type of material wood and does Yes the construction qualify If"Yes", qualifies for Construction as "conventional light El the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. 0Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight ❑X Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance 0 Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. X❑ of composition shingle. Is the roof mounted Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:Building/Eons/Photovoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes", qualifies for fastener? ❑ the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PhotoVo]talc-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Silfab Model Number: SIL-400 HC+ Listing Agency: 4 I:Building/Fonns/PhotoVoltaic-Checklist02-01-1 l.docx CITY OF TIGARD MASTER PERMIT IIII 1 COMMUNITY DEVELOPMENT Permit#: MST2023-00129 Date Issued: 05/15/2023 T I(1 A R.f) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: °2S112B613200 Jurisdiction: Tigard Site address: 14358 SW HALL BLVD Subdivision: COLONY CREEK ESTATES NO.5 Lot: 111 Project: Davey Project Description: Rooftop solar PV system 6.4 kW and(2)circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $4,480.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other Y Other Description: Roof top solar array 6.4 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: DAVEY,SCOTT P ION DEVELOPER LLC Required Items and Reports(Conditions) 14358 SW HALL BLVD 3214 NORTH UNIVERSITY AVE TIGARD,OR 97224 503 PROVO,UT 84604 PHONE PHONE: 888-781-7074 FAX: Total Fees: $457.42 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR :::;: n fhrnnnh RgS9_r1M_nnon ni i m hfnin n nnnu offhe nJec nr rfirnrfnfne fn nl INR by lli(/) Permittee Signature.Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • Building Permit Application RECE ` Residential FOR OFFICE USE ONLY Cityof Tigard �� Received fit Date/By: I' I 2/1 T.. Permit No.: myczo�f 2 —6_5 ip, 13125 SW Hall Blvd.,Tigard,OR 97223 y' w v w w II Phone: 503.718.2439 Fax: 503.598.19,tc OF 11 RD Review �7 n �^ DIVISION DateBy: �j0 ?j� Apr Other Permit: 1 1 ,\1:i 1 Inspection Line: 503.639.4175 BUI L ING©�V i�3�V� Date Ready/By: lams: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method:1 I'3- Supplemental Information EMI1ILE°11) IN TYPE OF WORK:, :. REQUIRED DATA 1-ANDI,-ANIII-PAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement •Other: PV Solar equipment,materials,labor,overhead,and the profit for the CATEGORY O CONSTRUCTION :: =% work indicated on this application. II 1-and 2-family dwelling ElCommercial/industrial Valuation: $4,480 0 Accessory building El Multi-familyNumber of bedrooms: El Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION.AND LOCATION Total number of floors: Job site address:14358 SW Hall Blvd New dwelling area: square feet City/State/ZIP:Tigard, Oregon, 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Davey Solar Install Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED;DATA:COMMERCIAL-USE CHECKLIST Subdivision: Colony Creek Estates Lot no.: 111 Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: 2S112B613200/R2028441 equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of solar panels on existing residential roof. Valuation: $ 6.4 kW.Addition of 2 0-30A circuits. Existing building area: square feet New building area: square feet IN PROPERTY OWNER 0 TENANT Number of stories: Name:Scott Davey Type of construction: Address: 14358 SW Hall Blvd Occupancy groups: City/State/ZIP: Tigard, Oregon, 97224 Existing: Phone:(503) 367-8588 Fax:( ) New: APPLICANT 0 CONTACT PERSON BUILDING.PERMIT FEES*.r Business name: ION DEVELOPER LLC (Please refer to{eeschedule) Contact name: Dustin Davidson Structural plan review fee(or deposit): Address: FLS plan review fee(if applicable): 4801 N University Ave#900 City/State/ZIP: Provo, UT 84604 Total fees due upon application: Phone:( 888) 781-7074 Fax: :( ) Amount received: E-mail: permits@ionsOlar.com PHOTOVtILTACSQLARPAtEISYSTENi:FEES* .. COAITRACOR Commercial and residential prescriptive installation of '- ' , > roof-top mounted PhotoVoltaic Solar Panel System. Business name: ION DEVELOPER LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 4801 N University Ave#900 Solar Installation Specialty Code checklist. City/State/ZIP: Provo, UT 84604 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 888) 781-7074 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 230394 Total fee due upon application: $201.60 Authorized signature: )a/f(,yt, 7J,,y1 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Dustin Davidson Date:4/7/2023 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doe 02/24/2011 440-4613T(11/02/COM/WEB) r RECEIVED Electrical Permit Application FOR OFFICE USE ONLY City of Tigard APR 1 0 2023 Received DateB Permit#: ■ 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TI`��I �. .hRD Related Permit#: 0 �00`/' I 1(_, U;1 P.I) Inspection Line: 503.639.4175 BUILDING D I V S i o f`'eady Date/By: Ions: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information _.:; }. :1 ,',:TYPE OF WORK'' '' z." T LAN REVIEW , ❑New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Demolition Other: PV Solar 0 Service or feeder 400 amps or more ❑Building over three stories. where the available faultcurrent Marinasand boatyards. ❑ :. .' . XATEGORY OF C'INSTRIUCTION , exceeds 10,000 amps at 150 volts or 0 Floating buildings. In 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family ❑Master builder ❑Other: ❑Fire pump.P" ❑Installation of 150 KVA or ,JOB SITE INFORMATION MO Llockno' Eli Emergency system. larger separately derived Job#: Job site address: 14358 SW Hall Blvd ❑Addition ofnew motor load of system. 100HP or more. ❑"A",`E","1-2","1-3", City/State/ZIP: Tigard, Oregon, 97224 ❑Six or more residential units. occupancy. 0 Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: Project name: Davey Solar Install ❑Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: ESCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Colony Creek Estates Lot#: 111 Includes attached garage. Tax map/parcel#: 2S112BB13200/R2028441 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 x" DESCRIPTION OE WORK .. Limited energy,residential Installation of solar panels on existing residential roof. (with above sq.ft.) 75.00 2 Limited energy,multi-family 6.4 kW.Addition of 2 0-30A circuits. residential(with above sq.ft.) 75.00 2 PROPEIiTY"OWNERRenewable Energy 0 See Page 2 ,..4..n'TENAANI' w Services or feeders installation,alteration,and/or relocation Name: Scott Davey 200 amps or less 100.70 2 Address: 14358 SW Hall Blvd 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, Oregon, 97224 601 amps to 1,000 amps 301.04 2 Phone:(503 ) 367-8588 Fax:( ) Over 1,000 amps or volts 552.26 2 Email: daveys1981@gmail.com Temporary services or feeders installation,alteration,and/or relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 111;APPLICANT ,"ID t,oN 'AC `"PERSON Branch circuits-c new,alteration,or extension,per panel A.Fee for branch circuits with Business name: ION DEVELOPER LLC above service or feeder fee, each branch circuit 7.42 2 Contact name: Dustin Davidson B.Fee for branch circuits without Address: 4801 N University Ave#900 service or feeder fee,first branch 2 branch circuit 1 $56.18 City/State/ZIP:Provo, UT 84604 Each add'l branch circuit 1 7.42 $7.42 2 Miscellaneous(service or feeder not included) Phone:(888) 781-7074 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: permits@ionsolar.com Reconnect only 67.84 2 v CONTRACTOR 1; ''" ` 4; - . " Pump or irrigation circle 67.84 2 Business name: ION DEVELOPER LLC Sign or outline lighting 67.84 2 Address: 4801 N University Ave#900 Signal circuit(s)or limited-energy panel,alteration,or extension. ❑ See Page 2 2 City/State/ZIP: Provo, UT 84604 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(888) 781-7074 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permits@ionsolar.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 230394 Electrical Lic.: C 1524 Suprv.Lic.: 6098S specifically listed(A hr min) 90.00/hr ELECTRICAL PERMIT FEES", Suprv.Electrician signature,required: ,���8 $197 16" Subtotal: Print name: David S Conrad Date: 4/7/2023 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): $23.66 atF, clt, Z..)asrc 'cat TOTAL PERMIT FEE: $220.82 Authorized signature: CD This permit application expires if a permit is not obtained within 180 Print name: Dustin Davidson Date:4/7/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELCPermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Fee for all residential systems combined: @ °Description .p75.00 Qty. Each I , Total Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 $133.56 2 Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 El Burglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance Heating,Ventilation and Air Conditioning with OAR 918-309-0040) 552.26 2 System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 ❑ Each additional inspection over allowable in any of the above: Other: Each additional inspection is 66 charged at an hourly(1 hr min) 90.25/hr 1 Inspections for which no fee is spfic ecially fisted(A hr min) 90.00/hr lam .;- Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): $133.56 (SEE OAR 918-309-0000) * Nmnber of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ D• ata Telecommunication Installation ❑ F• ire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ L• andscape Irrigation Control* ❑ M• edical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:ABuilding\Permits\ELC_PennitApp_ELR ERE.doe Rev 06/17/2015