Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Specifications
I NE5863 Lakeview Blvd., Suite 100 Lake Oswego, OR 97035 (503)627-0100 CCB#135901 CORPORATION RECEIVED a I ( LU.. CITY OF TIGARD BUILDING DIVISION Mercer Global — PPC082-230 12909 SW 68t'' Parkway, Suite 230 Tigard, OR 97223 PLEASE PROVIDE COMPLETED NFPA 72 RECORD OF COMPLETION AT FINAL INSPECTION FIRE ALARM s^ r CITY OF TIGARD,.* REVIEWD FOR CODE COMPLIANCE Approved: ] OTC: [ I Permit#: F P c a0 23- 00 a 6 j Address: ' 9(r) 9 sw. 6811, pkw� suite #: � 3 O By: t.{ Date: CSc- Z3 VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 5863 Lakeview Blvd.,Suite 100 -f Lake Oswego, OR 97035 / (503)627-0100 CCB#135901 CORPORATION TABLE OF CONTENTS A. Fire Alarm System 1) System Sensor PC2WL/SCWL—Ceiling Mount Horn Strobe& Strobe, White 3 DN-60938:B Indoor Selectable-Output Strobes and Horn Strobes for NOTI FI E R" Ceiling Applications by Honeywell Audio/Visual Devices General System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and A maximize profits with lower current draw and modern aesthet- ics. it The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With " white and red plastic housings, wall and ceiling mounting4.111, options, System Sensor L-Series can meet virtually any appli- cation requirement. The entire L-Series product line of ceiling-mount strobes and SCRL PC2WL horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices Architect/Engineer Specifications feature a plug-in design with minimal intrusion into the back box,making installations fast and foolproof while virtually elim- GENERAL inating costly and time-consuming ground faults. L-Series ceiling-mount strobes and horn strobes shall mount To further simplify installation,the L-Series utilizes a universal to a standard 4 x 4 x 1 1-inch back box,4-inch octagon back mounting plate so installers can mount them to a wide array of box, or double-gang back box. Two-wire products shall also back boxes. With an onboard shorting spring, installers can mount to a single-gang 2 x 4 x 17/8 inch back box.A universal test wiring continuity before the device is installed. mounting plate shall be used for mounting ceiling and wall Installers can also easily adapt devices to a suit a wide range products. The notification appliance circuit wiring shall termi- of application requirements using field-selectable candela set- nate at the universal mounting plate. Also, L-Series products, tings, automatic selection of 12- or 24-volt operation, and a when used with the Sync•Circuit Module accessory,shall be rotary switch for horn tones with two volume selections. powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with Features the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24- • Plug-in design with minimal intrusion into the back box volt-rated notification appliance circuit outputs shall operate • Tamper resistant construction between 16.5 and 33 volts. Indoor L-Series products shall Automatic selection of 12-or 24 volt operation operate between 32 and 120 degrees Fahrenheit from a regu- • at 15 and 30 candela lated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela • Field-selectable candela settings on ceiling units: settings including 15,30,75,95, 115, 150,and 177. 15,30,75,95, 115, 150,and 177 • Horn rated at 88+dBA at 16 volts STROBE • Rotary switch for horn tone and two volume selections The strobe shall be a System Sensor L-Series Model Universal mounting plate for ceiling units listed to UL 1971 and shall be approved for fire protective ser- • vice.The strobe shall be wired as a primary-signaling notifica- • Mounting plate shorting spring feature checks wiring conti- tion appliance and comply with the Americans with Disabilities nuity before device installation Act requirements for visible signaling appliances,flashing at 1 • Electrically compatible with legacy SpectrAlert and Hz over the strobe's entire operating voltage range.The strobe SpectrAlert Advance devices light shall consist of a xenon flash tube and associated lens/ • Compatible with MDL3 sync module reflector system. • Listed for ceiling mounting only HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signal- ing appliances,flashing at 1 Hz over the strobe's entire operat- ing voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pat- tern. These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non- coded power supply. DN-60938:B•5/15/17—Page 1 of 4 - SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8 inch back box.The module shall also con- trol two Style Y (class B) circuits or one Style Z (class A) cir- cuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F(0°C to 49°C) • Humidity Range: 10 to 93%non-condensing • Strobe Flash Rate: 1 flash per second • Nominal Voltage: Regulated 12VDC or regulated 24DC/ FWR1 • Operating Voltage Range2: 8 to 17.5V (12V nominal) or 16 to 33V(24V nominal) • Operating Voltage Range with MLD3: 8.5 to 17.5V (12V nominal)or 16.5 to 33V(24V nominal) • Input terminal wire gauge: 12 to 18 AWG • Ceiling-Mount Dimensions(including lens): 6.8" diame- ter 2.5"high(173 mm diameter 64 mm high) • Ceiling-Mount Surface Mount Back Box Skirt Dimen- sions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified(FWR)voltage is a non-filtered,time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. UL Current Draw Data UL MAX.STROBE CURRENT DRAW(MA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 °This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. Page 2 of 4—DN-60938:B•5/15/17 UL MAX. CHIME/STROBE CURRENT DRAW(MA RMS),2-WIRE HORN STROBE The 3.1k is the sound of the mini-horns. The EM(which stands for Electro-mechanical)is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. ' 8 VDC 16 VDC Candela 15 1 30 15 30 75 95 1 115 150 177 Temporal High 103 167 I 71 90 143 i 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temporal Low 95 166 I I 54 71 124 I 161 170 I 216 258 1 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 i 164 202 229 271 3.1K Non-Temporal Low 103 169 54 1I 88 131 155 187 217 259 16VFWR Candela 15 30 75 95 115 150 177 Temporal High 107 135 179 198 223 254 f 286 Temporal Low 78 101 , 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temporal Low 78 101 151 172 I 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 I 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 1 260 Horn Strobe Tones and Sound Output Data HORN AND HORN STROBE OUTPUT(DBA) 8-17.5 16-33 Volts Volts I Switch Position Sound Pattern dB DC 1 DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 I 83 3 Non-Temporal High 85 90 ' 90 4 1 Non-Temporal Low 76 84 84 5 I 3.1 KHz Temporal High 1 83 I 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 DN-60938:B•5/15/17—Page 3 of 4 r Product Drawings: L-Series Dimensions 2.47 1.37 ,--. '6.83 8.92 2.50 . .- .. ,. - 8'il cD 1:—: \\\\ „_______ .gi wMM H _ D, \N8: Ilimmiliiiiiiie CD cP::y Horn Strobes (Ceiling) Surface Mount Back Box(Ceiling) Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC-Listed —S4011 Ceiling horn strobes —S5512 Ceiling strobes —S5512 Strobe-only ALERT devices • FM Approved(All except ALERT models) • CSFM Listed: 7135-1653:0503(Ceiling Horns and Ceiling Horn Strobes),7125-1653:0504(Ceiling Strobes) Product Line Information CEILING HORN STROBES PC2WL(A) (-E)(-F), PC2RL(A) (-E)(-F). 2-Wire, Horn Strobe (White,Red). CEILING STROBES SCWL(A)(-E)(-F),SCRL(A)(-E)(-F).Strobe(White, Red). SCWL-CLR-ALERT.Strobe,ALERT(White). ACCESSORIES TR-2W,TR-2.Universal Ceiling Trim Ring(White, Red). SBBCWL,SBBCRL.Ceiling Surface Mount Back Box(White, Red). NOTE: "A"suffix indicates ULC-Listed model. ULC-listed devices include required French labeling. See Agency Listings for listing details. NOTE: "A"suffix indicates ULC-listed models, ULC models have FIRE/FEU marking on cover. NOTE: ULC-listed models add"-E"suffix for English only`FIRE" NOTIFIER® and SpectrAlert® are registered trademarks and marking on cover. Sync•CircuitTM is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use NOTE: ULC-listed models add "-F"suffix for French only "FEU" of this document is strictly prohibited. marking on cover. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. c E R r F E o We cannot cover all specific applications or anticipate all requirements. ENGINEERING A MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60938:B•5/15/17 5863 Lakeview Blvd.,Suite 100 Lake Oswego, OR 97035 (503)627-0100 CCB#135901 CORPORATION RECEIVED VIA VIAY 1 12023 CITY OF TIGARD Mercer Global — PPC082-230 12909 SW 68t' Parkway, Suite 230 Tigard, OR 97223 FIRE ALARM 5863 Lakeview Blvd., Suite 100 - � Lake Oswego, OR 97035 alg / (503)627-0100 CCB#135901 NB CORPORATION TABLE OF CONTENTS A. Fire Alarm System 1) System Sensor PC2WL/SCWL—Ceiling Mount Horn Strobe & Strobe, White 3 DN-60938:B Indoor Selectable-Output Strobes and Horn Strobes for NOT 1 F 1 E R® Ceiling Applications by Honeywell Audia/Visual Devices General System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthet- ics. The System Sensor L-Series offers the most versatile .y and easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With �` 441, white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any appli- cation requirement. The entire L-Series product line of ceiling-mount strobes and SCRL PC2WL horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices Architect/Engineer Specifications feature a plug-in design with minimal intrusion into the back box,making installations fast and foolproof while virtually elim- GENERAL hating costly and time-consuming ground faults. L-Series ceiling-mount strobes and horn strobes shall mount To further simplify installation,the L-Series utilizes a universal to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back mounting plate so installers can mount them to a wide array of box, or double-gang back box. Two-wire products shall also back boxes. With an onboard shorting spring, installers can mount to a single-gang 2 x 4 x 17/8 inch back box.A universal test wiring continuity before the device is installed. mounting plate shall be used for mounting ceiling and wall Installers can also easily adapt devices to a suit a wide range products. The notification appliance circuit wiring shall termi- of application requirements using field-selectable candela set- nate at the universal mounting plate. Also, L-Series products, tings, automatic selection of 12- or 24-volt operation, and a when used with the Sync•CircuitTM Module accessory,shall be rotary switch for horn tones with two volume selections. powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with Features the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24- • Plug-in design with minimal intrusion into the back box volt-rated notification appliance circuit outputs shall operate • Tamper resistant construction between 16.5 and 33 volts. Indoor L-Series products shall Automatic selection of 12-or 24 volt operation operate between 32 and 120 degrees Fahrenheit from a regu- • A At 15 and 30 candela lated DC or full-wave rectified unfiltered power supply. Ceiling astrobes and horn strobes shall have field-selectable candela • Field-selectable candela settings on ceiling units: settings including 15,30,75,95, 115, 150,and 177. 15,30,75,95, 115, 150,and 177 • Horn rated at 88+dBA at 16 volts STROBE • Rotary switch for horn tone and two volume selections The strobe shall be a System Sensor L-Series Model Universal mounting plate for ceiling units listed to UL 1971 and shall be approved for fire protective ser- • vice.The strobe shall be wired as a primary-signaling notifica- • Mounting plate shorting spring feature checks wiring conti- tion appliance and comply with the Americans with Disabilities nuity before device installation Act requirements for visible signaling appliances,flashing at 1 • Electrically compatible with legacy SpectrAlert and Hz over the strobe's entire operating voltage range.The strobe SpectrAlert Advance devices light shall consist of a xenon flash tube and associated lens/ • Compatible with MDL3 sync module reflector system. • Listed for ceiling mounting only HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signal- ing appliances,flashing at 1 Hz over the strobe's entire operat- ing voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pat- tern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non- coded power supply. DN-60938:B•5/15/17—Page 1 of 4 SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model • MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8 inch back box.The module shall also con- trol two Style Y(class B) circuits or one Style Z(class A) cir- cuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F(0°C to 49°C) • Humidity Range: 10 to 93%non-condensing • Strobe Flash Rate: 1 flash per second • Nominal Voltage: Regulated 12VDC or regulated 24DC/ FWR1 • Operating Voltage Range2: 8 to 17.5V (12V nominal) or 16 to 33V(24V nominal) • Operating Voltage Range with MLD3: 8.5 to 17.5V (12V nominal)or 16.5 to 33V(24V nominal) • Input terminal wire gauge: 12 to 18 AWG • Ceiling-Mount Dimensions (including lens): 6.8" diame- ter 2.5"high(173 mm diameter 64 mm high) • Ceiling-Mount Surface Mount Back Box Skirt Dimen- sions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified(FWR)voltage is a non-filtered,time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. UL Current Draw Data UL MAX.STROBE CURRENT DRAW(MA RMS) 1 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 °This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. Page 2 of 4—DN-60938:B•5/15/17 UL MAX. CHIME/STROBE CURRENT DRAW(MA RMS),2-WIRE HORN STROBE The 3.1k is the sound of the mini-horns. The EM (which stands for Electro-mechanical)is the sound of the SpectrAlert Advance ' line which uses an algorithm that hops frequencies between 2Hz and 4Hz. 8 VDC 16 VDC Candela 1 15 30 15 30 75 95 115 150 177 Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temporal Low 95 166 54 i 71 124 161 I 170 216 258 1 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 ! 202 229 271 3.1K Non-Temporal Low 103 I 169 54 88 131 155 187 217 259 16VFWR Candela 15 30 75 95 115 150 177 Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 I 199 1, 229 262 Non-Temporal High 107 135 179 ' 198 223 254 286 Non-Temporal Low 78 i 101 151 172 199 229 262 i 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 j 171 i 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data HORN AND HORN STROBE OUTPUT(DBA) 1 8-17.5 16-33 • Volts Volts Switch Position Sound Pattern dB I DC DC FWR I I 1 Temporal High 84 89 r 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal I Low 76 i 82 82 7 I 3.1 KHz Non-Temporal High 84 89 189 8 3.1 KHz Non-Temporal Low 77 83 83 DN-60938:B•5/15/17—Page 3 of 4 Product Drawings: L-Series Dimensions 2.47 1.37 _ ---_ 6.83 6.92 2.50 )7-*'.) cp „ryO O of am` �i \\ ,\\N8 c=, CD LzyPa---// J r , O Horn Strobes (Ceiling) Surface Mount Back Box(Ceiling) Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC-Listed —S4011 Ceiling horn strobes —S5512 Ceiling strobes —S5512 Strobe-only ALERT devices • FM Approved(All except ALERT models) • CSFM Listed: 7135-1653:0503 (Ceiling Horns and Ceiling Horn Strobes),7125-1653:0504(Ceiling Strobes) Product Line Information CEILING HORN STROBES PC2WL(A) (-E)(-F), PC2RL(A) (-E)(-F). 2-Wire, Horn Strobe (White, Red). CEILING STROBES SCWL(A)(-E)(-F),SCWL(A)(-E)(-F).Strobe(White,Red). SCWL-CLR-ALERT.Strobe,ALERT(White). ACCESSORIES TR-2W,TR-2.Universal Ceiling Trim Ring(White, Red). SBBCWL,SBBCRL.Ceiling Surface Mount Back Box(White, Red). NOTE: `A"suffix indicates ULC-Listed model. ULC-listed devices include required French labeling. See Agency Listings for listing details. NOTE: "A"suffix indicates ULC-listed models, ULC models have FIRE/FEU marking on cover. NOTE: ULC-listed models add"-E"suffix for English only"FIRE" NOTIFIER® and SpectrAlert® are registered trademarks and marking on cover. Sync•CircuitTM is a trademark of Honeywell International Inc. NOTE: ULC listed models add "-F"suffix for French only ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use "FEU" of this document is strictly prohibited. marking on cover. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F E fa We cannot cover all specific applications or anticipate all requirements. ENGINEERING B MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60938:B•5/15/17