Loading...
Permit (2) /77t5` lot 5--co 15 z City of Tigard RECEIVtD ,, . . . . . APR 1 '`f`3 Building Division 1 ° � 13125 SW Hall Blvd,Tigard, OR 97223 GARD Phone: 503.718.2439 Fax 503.598.1960 �! OF�� T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 11820 SW Manzanita St, Tigard, Oregon, 97223 City: Zip: Owner's Name: Michael Leigland Date: 04 / 14 /2023 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? © No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure 2 Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes Q Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structuresIf"Yes", qualifies for other than © Yes the prescriptive path. above ❑ No 1 I:Building/Forms/Photo Voltaic-Checklist02-01-11.docx Is the construction Type of material wood and does © Yes If"Yes", qualifies for the construction qualify prescriptive No the path. Construction as"conventional light ❑ p p frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. © Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. © If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight © Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance YeS If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑Q of composition shingle. Is the roof mounted 0 Yes Connections of solar assembly the solar assembly connected to roof No If"Yes",pqrescriptive p for to the roof framing or blocking ❑ the prescriptive path. directly? 2 I:Building/Forms/Photovoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of ❑ Yes If"Yes", qualifies for fastener? the prescriptive path. ❑ No Is the roof decking of WSP min. 1/4"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof © Yes the prescriptive path. surface. ❑ No 3 I:B uilding/Forms/PhotoVoltaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: QCeIIs Model Number: Q.PEAK DUO BLK ML-G10+ 400 Listing Agency: CSA 4 I1Building/Forms/PhotoVoltaic-Checklist02-01-11.docx CITY OF TIGARD MASTER PERMIT ' 111 I ' COMMUNITY DEVELOPMENT Permit#: MST2023-00152 Date Issued: 05/16/2023 T f i;,.fi 1-.7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S134CA00515 Jurisdiction: Tigard Site address: 11820 SW MANZANITA ST Subdivision: PANORAMA NO.2 Lot: 27 Project: Leigland Project Description: Rooftop solar PV system 12.8 kW BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $11,548.16 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add9 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 12.8 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: LEIGLAND,MICHAEL A&KEIKO F BRS FIELD OPS LLC Required Items and Reports(Conditions) 11820 SW MANZANITA ST 1403 NORTH RESEARCH WAY TIGARD,OR 97223 OREM,UT 84097 PHONE PHONE: 855-205-2530 FAX: Total Fees: $357.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc2nnl_nn1 n fhrni i AP Q59_nn1_ n Vnh,mw htzin A rnnv of fhc ri doe nr riiranf nnnefinne fn ni Mr Fit/, iiinnr'cn'39.29 1 QA7 nr 1 Ann TV)"YIAA Issued By: /(/JI Permittee Signature: t Call 503.639.4 y 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application " i1 1� Residential RECEIVED City of Tigard p r� ) Received ap 4 �{ A R , / 2 23 DateBy: I ti • I i 1 V Permit No.:VIS1)Opt/j _/�//t 62 13125 SW Hall Blvd.,Tigard,OR 97223` �' ° "1111 Plan Review A/ '/ 2,, / 1 ` L�1 of Phone: 503.718.2439 Fax: 503.598.19 10I9-0�t� Date By: /7 7 �`/ Other Permit: T I G A R D Inspection Line: 503.639.4175 uI T r OF TIGA D Date Ready/By: NN Juris: ® See Page 2 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method:WV•— 131/013 Supplemental Information �,� I 1. � Notified/Method: OuL-rhI r hvi El New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the 'p f ; work indicated on this application. ❑ 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ 11,548.16 ❑Accessory buildingMulti-family tom/ ElNumber of bedrooms: cl 0 Master builder 0 Other: Number of bathrooms: ' Im t I Total number of floors: Job site address: 11820 SW Manzanita St,Tigard,Oregon,97223 New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Michael Leigland Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet h fi t dl i ;, ; Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the f r ✓f y f ✓�" ' W fi work indicated on this application. Rooftop Solar PV Valuation: $ Existing building area: square feet New building area: square feet ;' r, IZ ;.. Z.,A'. . ,,.' ' x"„ 5)4 0': Number of stories: Name: Michael Leigland Type of construction: Address: 11820 SW Manzanita St,Tigard,Oregon,97223 Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) 1 New: ,i 4 NA X,:00 . P?..? ..,, f,.,.f„,� ., `�,.� . ,} .. .I .,�.,..'; .; r;,�# 4� "R 1 tk Business name: BRS Field Ops, LLC , Structural plan review fee(or deposit): Contact name: Courtnie Hougaard FLS plan review fee(if applicable): Address: 1403 N Research Way Total fees due upon application: City/State/ZIP: Orem, UT 84097 Phone:( 385)482-0045 Fax: :( ) Amount received: E-mail: permitting.deparment@blueravensolar.com .,u I' �'� r r Wf 0r lx f Commercial and residential prescriptive installation of ° It ,i,,,_ , �.. roof-top mounted Photo Voltaic Solar Panel System. , � ,e ram �,�.,,, , . ,r. ��„� .�;� ��� .f��, Business name: BRS Field Ops, LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1403 N Research Way Solar Installation Specialty Code checklist. City/State/ZIP: Orem, UT 84097 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 385)482-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 227185 Total fee due upon application: $201.60 Authorized signature: in, . This permit application expires if a permit is not obtained ot{t'ftcie-#ot4 12ar6/ Permitting Coordinator within 180 days after it has been accepted as complete. Print name: Courtnie Hougaard f- Date: 04/14/2023 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-46 13T(1 1/02/COM/WEB) Etectrical Permit Application FOR OFFICE USE ONLY ` Cit`r of b Tigard Date/B it# Received A .( Q i ' : Perm : M t 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review 8 Phone: 503.718.2439 Fax: 503.598.1960 DateB c Related Permit#: Inspection Line: 503.639.4175 Ready Date/By: Juris: ia See Page 2 for 1ItiAIIDg Internet: www.tigard-or.gov Notified/Method: Supplemental information F 12, .,r e .row .<,2r,,._,,.4. .. ,44;:..... ❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Demolition ❑Other: ❑Service or feeder 400 amps or more ❑Building over three stories. where the available fault current ❑Marinas and boatyards. t n, �. " ° exceeds 10,000 am s at 150 volts or Floatin buildim s. dwelling 0 ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use a icultural 0 1-and 2-familyCommercial/industrial � amps for all other installations. buildings. ❑Multi-family 0 Master builder ❑Other: 0 Fire pump. 91 ' ❑Emergency system 0 larger larg In stallation l 5deriivedor Addition of new motor load.of system. Job#: Job site address: 11820 SW Manzanita St,Tigard, Oregon,972 o0BP or more. ❑"A","E","1-2","1-3", ❑Six or more residential units. occupancy. City/State/ZIP: ❑Recreational vehicle ar ❑Health-care facilities. P Suite/bldg./apt.#: Project name: Michael Leigland ❑Hazardous locations. ❑Supply voltage for more than ❑Service or feeder 600 amps or more 600 volts nommal Cross street/directions to job site: ; Description `Qtv. I Each I ` I Total New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel# Ea.add l 500 sq.ft.or portion 33.92 1 < , , ,'.- ,;I-I„,, fi ie 4, r.., .... .... r.... :"II U. .,". Limited energy,residential Rooftop Solar PV (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) t p l z Renewable Energy 0 See Page 2 °' ` '� `� ° - •� -� % �� i - Services or feeders installation,alteration,and/or relocation Name: Michael Leigland 200 amps or less 100.70 2 Address: 11820 SW Manzanita St,Tigard, Oregon,97223 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449.670.and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 Branch circuits—new,alteration,or extension,per panel Business name: BRS Field Ops, LLC above service or feeder tee, 7.42 2 each branch circuit Contact name: Courtnie Hougaard B.Fee for branch circuits without service or feeder fee,first Address: 1403 N Research Way branch circuit 56.18 2 City/State/ZIP: Orem, UT 84097 Each add'1 branch circuit 7.42 2 Phone: 385)482-0045 Miscellaneous(service or feeder not included) ( Fax: : ( ) Each manufactured or modular 67.84 2 Email: permitting.department@blueravensolar.com dwelling,service and or feeder Reconnect only 67.84 2 /, ,w .,fTM, . . ,. <, - Pump or irrigation circle 67.84 2 Business name: BRS Field Ops, LLC Sign or outline lighting 67.84 2 Address: 1403 N Research Way Signal circuit(s)or limited-energy 0 See Page 2 2 panel,alteration,or extension. City/State/ZIP: Orem, UT 84097 Each additional inspection over allowable in any of the above Additional inspection(I hr min) 66.25/hr Phone:( 385) 482-0045 Fax:( ) Investigation(I hr min) 90.00/hr Email: permitting.department@blueravensolar.com Industrial plant(lhrmin) 78.18/hr Inspections for which no fee is CCB Lie.: 227185 Electrical L3c.: C1493 i Suprv.Lie.: 6394S etfically listed(�4 hr min) 90 00!In Suprv.Electrician signature,required: ,t Subtotal: Print name: Shan Whittaker Date: 04/14/2023 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: COW /We.i Oi(9 arrt� TOTAL PERMIT FEE: g Permitting Coordinator This permit application expires if a permit is not obtained within 180 Print name: Courtnie Hougaard Date: 04/14/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\BuildingPPermits\ELC PermitApp_ELF ERE.doc Rev 06/17/2015 440-4615T(I I/OSiCOM,wEB � Y Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Description 1 Qtr I Each Total * Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 El Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: El Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(1/2hr ) Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): (SEE OAR 918-309-0000) * Number of inspections allowed per permit. Check Type of Work Involved: El Audio and Stereo Systems El Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC El Instrumentation El Intercom and Paging Systems El Landscape Irrigation Control* ❑ Medical El Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\PermitstELC_PermitApp_ELR_ERE.doc Rev 06/17/2015