Plans (20) A ma B so C ■ D m E ■ F ■ G no H GENERAL NOTES NEW PV PROJECT NOTES: SYSTEM : I 1 .600 kWp 1 1.1.2 THIS PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THENATIONALELECTRIC rCODE (NEC) ARTICLE 690, AL A S'S LISTING AND INSTALLATION RECElVEDINSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. FLATT RESIDENCE ELECTRICAL SERVICE ■ 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM SEP 2 0 2023 ■ INSPECTED PRIOR TO PARALLEL OPERATION 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED CITY OF TIGARD WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B) 14445 SW 87TH CT BUILDING DIVISION CONTRACTOR 1.1.5 ALL PV SYSTEM COMPONENTS;MODULES, UTILITY-INTERACTIVE INVERTERS,AND 1 SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN TIGARD OR 97224 UNITY ELECTRICAL SERVICE 2 PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215,AND NFPA 70 CLASS C FIRE INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519 SHEET LIST TABLE PHONE: 1-360-559-8699 COMBINER BOX(ES):UL 1703 OR UL 1741 ACCESSORY ASSESSOR'S #: 2 S 111 AA01500 ADRESS: 600 S 74TH PLACE,RIDGEFI 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP SHEET NUMBER SHEET TITLE ELD,WA 98684 COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. T-001.00 COVER PAGE ■ 1.1.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND SOURCE G-001.00 NOTES ■ LIC.NO.: UNITYES797CH CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILLil,BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE HIC.NO.: INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING[NEC A•101.00 SITE PLAN ELE.NO.: I UNAUTHORIZED USE OF THIS 110.3]. _ A-102.00 ELECTRICAL PLAN DRAWING SET WITHOUT WRITTEN 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF PERMISSION FROM CONTRACTOR IS IN EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE A-103.00 SOLAR ATTACHMENT PLAN VIOLATION OF U.S.COPYRIGHT LAWS 3 WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. a h AND W BE SUBJECT TO CIVIL E-601.00 LINE DIAGRAM DAMAGE S AND PROSECUTIONS 1.2.1 SCOPE OF WORK: ■ - E-602.00 DESIGN TABLES NEW PV SYSTEM: 1 1.600 kW 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF ' THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BEitt. 4 E-603.00 PLACARDS FLATT RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, I S-501.00 ASSEMBLY DETAILS SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE £ ",; ■ PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. R-001.00 RESOURCE DOCUMENT ■ RESIDENCE 1.3.1 WORK INCLUDES: • R-002.00 RESOURCE DOCUMENT 1.3.2 PV ROOF ATTACHMENTS-SUNMODO EZ ROOF MOUNT KIT WITH LFOOT OFFICE COPY sill ` . 14445SW87THCT, 1.3.3 PV RACKING SYSTEM INSTALLATION-SUNMODO SMR100 _` _. : R-003.00 RESOURCE DOCUMENT TIGARD,OR 97224 1.3.4 PVMODULEANDINVERTERINSTALLATION- AERIAL PHOTO R-004.00 RESOURCE DOCUMENT HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+400W 1 APS DS3-L 4 1.3.5 PVEQUIPMENTGROUNDING 01 PROJECT INFORMATION APN:2S111AA01500 1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX NOT TO SCALE 1.3.7 PVLOADCENTERS(IFINCLUDED) OWNER ENGINEER OF RECORD 1.3.8 PV METERINGIMONITORING(IF INCLUDED) NAME: JAMES ELWOOD FLATT 1.3.9 PV DISCONNECTS — 1.3.10 PV GROUNDING ELECTRODE 8 BONDING TO(E)GEC PROJECT MANAGER 1.3.11 PV FINAL COMMISSIONING PHONE: CONNOR LEE,STEPHEN ZOOK CITY OF MAPS) ACIDITY OF PERMIT PHONE: 36D-559S699 ■ ■ 1.3.12 (E)ELECTRICAL EQUIPMENT RETROFIT FOR PV i2E VIEWED ro CODi. COO CIA;`NC 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCALBUILDINGCOUt 1 ` ' 8 THE ISSUANCE OF A PERMIT CONTRACTOR Approved: I -' ' BASED ON CONSTRUCTION NAME: UNITY ELECTRICAL SERVICE O'I'C: 1I m PHONE: 1-360-559-8699 DOCUMENTS AND OTHER ?j3 '��' DATA SHALL NOT PHFVF ;I AUTHORITIES HAVING JURISDICTION Permit #: �51 5 THE CODE OFFICIAL FF? i, BUILDING: WASHINGTON COUNTY OREGON Address: `'- -- -{S g30V— C' I _ REQUIRING THE CORE F' ZONING: WASHINGTON COUNTY OREGON PAPER SIZE:11'x1T(ANSI B) SLIIIC #: —T OF ERRORS. rr UTILITY: PORTLANOGENERALELECTRIC SCOPE OF WORK By: Date: ��7/S3 DESIGN SPECIFICATIONS COVER PAGE y OCCUPANCY: II SYSTEM SIZE: STC:29 X 400W=11.600KW CONSTRUCTION: SINGLE-FAMILY DATE:07.06.2023 PTC:29 X 371.5W=10.774KW SWINEZST ZONING: RESIDENTIAL ■ (29)HANWHA 0-CELLS Q.PEAK DUO BLK ML-G10+400W GROUND SNOW LOAD: 40 PSF ■ DESIGN BY: U.P. (15)APS DS3� WIND EXPOSURE: B WIND SPEED: 110 MPH CHECKED BY: M.M. PLAT MAP N APPUCABLE CODES A STANDARDS REVISIONS 6 02 BUILDING: OSISC 2010,OSSC 2019 ATTACHMENT TYPE: SUNMODO EZ ROOF MOUNT KIT WITH L FOOT W E RESIDENTIAL: ORSC 2021 NOT TO SCALE ELECTRICAL: OESC 2021 MSP UPGRADE: NO S FIRE: OSSC 2019 T-001 .00 A • B • C • D • E a F • G 34 H A • B • C • D ■ E • F • G a H 2.1.1 SITE NOTES: 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN ' 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, 1 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. Li , 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING 2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL ROOF VENTS. OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. ELECTRICAL SERVICE ■ 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL 2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR ■ EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. MARKED GREEN IF#4 AWG OR LARGER NEC 250.119] 2.1.6 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF 250.106. IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A GROUNDING ELECTRODE CONTRACTOR COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 AND AHJ. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1)THROUGH (3)TO REDUCE UNITY ELECTRICAL SERVICE 2 2.2.1 EQUIPMENT LOCATIONS: FIRE HAZARDS 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. PHONE: 1-360-559-8699 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: ADRESS: 600 S 74TH PLACE,RIDGEFI TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLE 310.15(B)(1). 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE ELD,WA 98684 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED 'LINE 690.34. SIDE(TYPICALLY THE UPPER TERMINALS). 2.2.5 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A ■ SIGHT OF THE AC SERVICING DISCONNECT. VISIBLE-BREAK SWITCH ■ LIC.NO.: UNITYES797CH 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN HIC.NO.: NEC APPLICABLE CODES. FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH ELE.NO.: UNAUTHORIZED USE OF THIS 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN 690.12(A)THROUGH(D). DRAWING SET WITHOUT WRITTEN APPROPRIATE. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9,AND 240. PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN AND WILL BE SUBJECT TO CIVIL 3 2.3.1 STRUCTURAL NOTES: ACCORDANCE WITH NEC 110.3(B). DAMAGES AND PROSECUTIONS. 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT 2.6.7 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEW PV SYSTEM: 11.600 kWl INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, NEC 690.11 AND UL1699B. AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAYISUBARRAY,ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. 2.7.1 INTERCONNECTION NOTES: F LATT 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH NEC 705.12 ■ ROOF-PENETRATING TYPE,IT SHALL BE FLASHED&SEALED PER LOCAL REQUIREMENTS. 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE ■ RESIDENCE 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/APPROVED RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. PERCENT OF THE AMPACITY OF THE BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE 14445 SW 87TH CT, 2,3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(B)(3)(2)]. SPECIFIED BY THE RACKING MANUFACTURER. 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL RATING OF ALL TIGARD,OR 97224 2.3 6 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE 4 THE ROOF FRAMING MEMBERS. COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12(B)(3)(3). 2.7.5 FEEDER TAP INTERCONNECTION(LOAD SIDE)ACCORDING TO NEC 705.12(B)(1)AND(2) APN.2S111AA01500 2.4.1 WIRING&CONDUIT NOTES: 2.7.6 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.11 WITH SERVICE ENTRANCE ENGINEER OF RECORD 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND CONDUCTORS IN ACCORDANCE WITH NEC 230.42 WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM TO LIMIT UP-SIZING. ADDITIONAL FASTENING NEC 705.12(E)]. 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. ■ 2.4.4 VOLTAGE DROP LIMITED T01.5%. ■ 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE 5 PHASE C OR L3-BLUE,YELLOW,ORANGE**,OR OTHER CONVENTION NEUTRAL-WHITE OR GRAY PAPER SIZE:11'x 17'(ANSI B) IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE[NEC 110.15]. NOTES 2.5.1 GROUNDING NOTES: DATE:07.06.2023 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DESIGN BY: U.P. ■ DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. ■ 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE CHECKED BY: M.M. 250.122. 6 2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED REVISIONS GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICROINVERTER MANUFACTURERS'INSTRUCTIONS. . G-001 ,00 A • B • C • D li E • F • G a H A • B • C ma D is E • F • G • H UMfY NOTE: AC DISCONNECT WITHIN ELECTRICAL SERVICE ■ 10'OF UTILITY METER ■ <10' CONTRACTOR UTILITY METER AC DISCONNECT UNITY ELECTRICAL SERVICE 2 AC LOAD CENTER 1 MAIN ELECTRICA�IN DE)PANEL GENERAL NOTES PHONE: 1-360-559-8699 ABBESS: 600 S 74TH PLACE,RIDGEFI 1. FIELD VERIFY ALL MEASUREMENTS ELD,WA 98684 1 I 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ■ `, ■ LIC.NO.: UNITYES797CH 26' 7" — — — PROPERTY LINE HIC.NO.: 1 ELE.NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISS 1 CTOR IS VIOLATIDIN ON OF U.S.COPYRFROMRIGHT LAWSN a IAND WILL BE SUBJECT TO CIVIL 3 DAMAGES AND PROSECUTIONS. 0 16'-7" NEW PV SYSTEM: 11.600 kW1 o 1 I— e 0 F LATT Ion ■ c) ■ RESIDENCE 25'-8" 1.*N'N'''''N'H 14445 SW 87TH CT, .� — , — ENTRANCE TIGARD,OR 97224 I-1 4 AREA OF WORK APN:2S111AA01500 I I 69'-10" ENGINEER OF RECORD l • 5 PAPER SIZE 11"a 17"(ANSI B) SW INEZ ST SITE PLAN DATE:07.06.2023 ■ I DESIGN BY: V.P. CHECKED BY: M.M. SITE PLAN N 6 O 1 1/24"=1'-0" 0 12' 24' w E REVISIONS 5 A-101 .00 A mB m C mD • E • F • G • H A . B . C • D . _ ■ F . G ■ H PLAN VIEW TOTAL ROOF AREA:1754.87 SQ.FT. PLAN VIEW TOTAL PV ARRAY ARE:612.5 SQ.FT. 1 PERCENTAGE OF ROOF SPACE USED BY SOLAR PV ARRAYS:35.93% INTERIOR PV EQUIPMENT (E)(1)MAIN ELECTRICAL PANEL ELECTRICAL SERVICE ■ 18" FIRE ACCESS PATH EXTERIOR PV EQUIPMENT (N)(1)AC LOAD CENTER I (N)(1)AC DISCONNECT 18" FIRE ACCESS PATH (E)(1)UTILITY METER - 1 -NI UNITY ELECTRICAL SERVICE 2 (N)(1)JUNCTION BOX ' GENERAL NOTES ADRESS: 600 S 74TH699 PLACE,RIDGEFI \\ \\'; 1. FIELD VERIFY ALL MEASUREMENTS ELD,WA 98684 3' FIRE ACCESS PATH 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ■ O \ A O 3. UTILITY HAS 24HR UNRESTRICTED ACCESS ■ LIC.NO.: UNITYES797CH TO THE PHOTOVOLTAIC SYSTEM METER AND HIC.NO.: 0 O \ A O DISCONNECT AT SERVICE ENTRANCE. ELE,NO.: UNAUTHORIZED USE OF THIS O \ O A ARRAY 2-3.200 KW /// FIRE CLEARANCE DRAWING SET WITHOUT WRITTEN 0 PERMISSION FROM CONTRACTOR IS IN \ VIOLATION OF U.S.COPYRIGHT LAWS 3 x8 (N)MODULES O MODULE STRINGING ANDAGEL ANBE D BJECT O CIVIL [ ] DAMAGES AND PROSECUTIONS. 0 0 O A TILT:19 DEGREES \\ ROOF PITCH:4:12 NEW PV SYSTEM: 11.600 kW AZIMUTH:90 DEGREES O MODULE STRINGING i O 0 F LATT ARRAY 1-8.400 KW O MODULE STRINGING ■ [x21](N)MODULES S DEGREES TILT:1 ROOF RESIDENCE ROOF PITCH:4:12 14445 SW 87TH CT, AZIMUTH:270 DEGREES 0 cb 0TIGARD,OR 97224 4 co APN:2S111AA01500 O O \ ENGINEER OF RECORD ■ co co 0 ■ co co0 0 O \ 3' FIRE ACCESS PATH 5 \\\\\\\\\\\\\\\ \\\\\\\\\\\\\\ ' PAPER SIZE:II'x17'(ANSI B) \\\ (�\\\\\\ ' 41.1" ELECTRICAL PLAN DATE:07.06.2023 ■ T--- 1 MODULE; DESIGN BY: V.P. HANWHA Q CELLS ■ CHECKED BY: M.M. 6 ELECTRICAL PLAN 118"=1'-0" 0 4' 8' N 74" Q.PEAK DUO BLK ML G10+400W REVISIONS 01 W N E 400 WATTS S A • B A-102"00 C D • E F • G • H A • B • C • D am E • F • G • H 1 UNITY ELECTRICAL SERVICE I ����� -7/7 _ /7/7- /�� CONTRACTOR UNITY ELECTRICAL SERVICE 2 - -0 -o- - - - ® - - - -0- - - -a- �- - - o-� /do- _ _ - _ f GENERAL NOTES PHONE: 1-360-559-8699 /� _ _ _ _ _ v ADRESS: 600 S 74TH PLACE,RIDGEFI / — — ° / 1. FIELD VERIFY ALL MEASUREMENTS ELD,WA 98684 — [� 2. ITEMS BELOW MAY NOT BE ON THIS PAGE 777; 3. UTILITY HAS 24HR UNRESTRICTED ACCESS I ° ROOF ATT.TYP. @48" MAX TO THE PHOTOVOLTAIC SYSTEM METER AND ■ LIC.NO.: UNITYES797CH ROOF TRUSSES HIC.NO.: LE. EN NO.: USE OF THIS _ _ _ _ _ _ _ _ _ _ 7 /j DRAWING SET WITHOUT WRITTEN 2X4" TRUSS @24" O.C. I - // 3'ROOF OUTLINE OFFSET PERMISSION FROM CONTRACTOR IS IN _ _ _ - - VIOLATION OF U.S.COPYRIGHT LAWS 3 - -� - - - �_- AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. ROOF ATT.TYP. 24" o- 41' 4" @ MAX �_ FLUSH MOUNT SOLAR MODULES NEW PV SYSTEM: 11.600 kWF (WITHIN 36" OF ROOF LINE) ATTACHED TO ROOF SURFACE(SEE _ _ _ o SHEET S-501.D0 FOR MOUNTING DETAILS) FLATT / ROOF MATERIAL IS ASPHALT SHINGLE I _ _ _ �_ _ _ ■ RESIDENCE 14445 SW 87TH CT, TIGARD,OR 97224 4 APN:2S111AA01500 _ EØENGINEER OF RECORD 5 PAPER SIZE'11"x 17'(ANSI B) SOLAR ATTACHMENT PLAN 41.1" DATE:07,06.2023 ■ MODULE: ■ DESIGN BY: V.P. HANWHA Q-CELLS CHECKED BY: M.M. 6 01 SOLAR ATTACHMENT PLAN N E 74" Q.PEAK DUO BLK ML G10+400W 400 WATTS REVISIONS 118"=1'-0" 0 4' 8' W A . B • • • B . • . A-103.00 CDE FG • H A ■ B ■ C ■ D ■ E ■ F ■ G ■ H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT-CARRYING TEMP.CORR. CONDUIT FILL CONT. MAX.CURRENT DERATED ID TYPICAL CONDUCTOR CONDUIT CONDUCTORS IN CONDUIT OCPD EGC FACTOR FACTOR CURRENT (125%) BASE AMP. AMP. TERM.TEMP.RATING AMP.@ TERMINAL 1ail k.,... 1� 1 1 12 AWG THWN-2,COPPER 075"DIA PVC-40 6 20A 8 AWG THWN-2,COPPER 0.96(33°C) 0.8 16A 20A 30A 23.04A 75°C 25A 2 1 6 AWG THWN-2,COPPER 0.75"DIA PVC-40 2 60A 6 AWG THWN-2,COPPER 0.96(33°C) 1 48A 60A 75A 72A 75°C 65A 3 1 6AWGTHWN-2,COPPER 0.75"DIA PVC-40 2 N/A 6 AWG THWN-2,COPPER 0.96(33°C) 1 48A 60A 75A 72A 75°C 65A ELECTRICAL SERVICE ■ I 1. SYSTEM DESIGN CALCULATIONS REPORT CONTRACTOR 1.1. PV SOURCE CIRCUIT VOLTAGE RANGE TEST THIS TEST CONFIRMS THAT THE VOLTAGE OF THE PV SOURCE CIRCUIT WILL ALWAYS REMAIN UNITY ELECTRICAL SERVICE 2 WITHIN THE DC INPUT VOLTAGE WINDOW OF THE SYSTEM'S INVERTER,MICROINVERTERS,OR POWER OPTIMIZERS. 1.1.1. (1) HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+400W(400W) IN SERIES PHONE: 1-360-559-8699 ADRESS: 600 S 74TH PLACE,RIDGEFI SECTION PROPERTIES VALIDATION TESTS ELD,WA 98684 (1)HANWHA Q-CELLS Q.PEAK DESCRIPTION DUO BLK ML-G10+400W(400W)IN THE MINIMUM VMP MUST EXCEED ■ SERIES THE MINIMUM INPUT VOLTAGE OF I LIC.NO.: UNITYES797CH 1 CONNECTED DEVICE APS DS3-L THE CONNECTED DEVICE PASS HIC.NO.: ELE.NO.: CONNECTED DEVICE TYPE MICROINVERTER UNAUTHORIZED USE OF THIS DESIGN LOW DRAWING SET WITHOUT WRITTEN TEMP. -10°C 31.88V> 16V=TRUE PERMISSION FROM CONTRACTOR IS IN DESIGN HIGH TEMP. 33°C VIOLATION OF U.S.COPYRIGHT LAWS 3 HANWHA Q-CELLS Q.PEAK DUO THE MAXIMUM VOC MUST NOT AND WILL BE SUBJECT TO CIVIL MODULE BLK ML-G10+400W 2 EXCEED THE MAX INPUT VOLTAGE PASS TO UTILITY DAMAGES AND PROSECUTIONS. MODULE VMP 37.13V OF THE CONNECTED DEVICE SYSTEM EQUIPPED WITH RAPID SHUTDOWN GRID(UG) NEW PV SYSTEM: 11.600 kWi MODULE VOC 45.3V 49.57V<60V=TRUE DISCONNECT PER NEC 690.12 A A A MICROINVERTER MIN.INPUT SYSTEM COMPLIANT WITH NEC 690.13 FLATT 16V VOLTAGE (29)HANWHA Q-CELLS MICROINVERTER MAX.INPUT Q.PEAK DUO BLK ML-G10+ L2 ■ VOLTAGE 60V 400W N ■ RESIDENCE MOUNTING METHOD FLUSH ROOF MOUNT 100A AC LOAD CENTER L1 TEMP.COEFFICIENT VOC -0.122 V/°C (15)APS DS3-L 120/240V, 10, 3W 14445 SW 87TH CT, VOLTAGE LOSS DUE TO 0.0 MICROINVERTER TIGARD,OR 97224 DEGRADATION DERATE I 20A VOLTAGE LOSS DUE TO 4 TOLERANCE DERATE 0.0 0 S \ ®bt - (E) APN:2S111AA01500 — INVERTER MIN.VOLTAGE 9 '� ��� UTILITY RE° METER ENGINEER OF RECORD INCREASE DUE TO HIGH 0.0 IN BRANCH _ TEMPERATURES gFx GROUND CALCULATIONS 20A ROD ■ A.STRING VOC AT LOW CD ( CB2 ) I ---I I TEMPERATURE 49.57V 10 ,_.e ,-. ',�, ® ,N, (E)GROUNDING in THE MODULE VOC(45.3V)WILL INCREASE TO 49.57V AT THE IN BRANCH — — RE' Ll ELECTRODE DESIGN LOW TEMPERATURE(-10°C). a.A. AC DISCONNECT,60A p (E) (-10°C-25°C)X-0.122V/°C+45.3V=49.57V MAIN 200A 49.57V X 1 =49.57V O = N' 20A 5 ( CB1 ) 60A FUSES Q N PAPER SIZE:11"x 17 (ANSI B) B.STRING VMP AT HIGH 10 L2 �-► TO(E) ° LOADS► 31.88V TEMPERATURE IN BRANCH — a A w I c ,� I LI LINE DIAGRAM ESTIMATED CELL TEMPERATURE EQUALS THE DESIGN HIGH L1 N L2 I (E)MAIN ELECTRICAL PANEL DATE:07.06.2023 TEMPERATURE(33°C)PLUS 35°C(THE ESTIMATED DIFFERENCE BETWEEN AMBIENT TEMPERATURES AND THE CELL TEMPERATURE ( SWI ) 240/120 V 10,3W I JUNCTION BOX I DESIGN BY: U.P. FOR A FLUSH ROOF MOUNT). 0MODULE STRINGING MAIN BUSS:200A ■ EQUIPMENT LEFT I EQUIPMENT RIGHT MAX BREAKER SIZE: CHECKED BY: M.M. 33°C+35°C=68°C OF LINE IS(N)NEW OF LINE IS(E)EXISTING (200A x 1.2 -200A=40A THE MODULE VMP(37.13V)WILL DROP TO 31.88V AT THE DESIGN O MODULE STRINGING UNLESS OTHERWISE NOTED. UNLESS OTHERWISE NOTED. ) REVISIONS 6 HIGH TEMPERATURE(33°C). (68°C-25°C)X-0.122V/°C+37.13V=31.88V O MODULE STRINGING E-601 .00 A - B ■ C ■ D • E ■ F • G • H A • B • C • D • E • F • G ■ H • Iiiii , . a '' ELECTRICAL SERVICE ■ lo CONTRACTOR UNITY ELECTRICAL SERVICE 2 PHONE: 1-360-559-8699 SYSTEM SUMMARY MODULES ADRESS: 600 S 74TH PLACE,RIDGEFI BRANCH#1 BRANCH#2 BRANCH#3 REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING ELD,WA 98684 INVERTERS PER BRANCH 5 5 5 PMI.29 29 HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+400W 400W 371.5W 11.14A 10.77A 45.3V 37.13V -0.122V/°C(-0.27%/°C) 20A MAX AC CURRENT 16A 16A 16A MAX AC OUTPUT POWER 3,840W 3,840W 3,840W ■ ARRAY STC POWER 11,600W INVERTERS • LIC.NO.: UNITYES797CH ARRAY PTC POWER 10,774W REF. Orr. MAKE AND MODEL AC GROUND OCPD RATED MAX OUTPUT MAX INPUT MAX INPUT CEC WEIGHTED HIC.NO.: MAX AC CURRENT 48A VOLTAGE , RATING POWER CURRENT CURRENT VOLTAGE EFFICIENCY ELE.NO.: MAX AC POWER 11,520W 11-15 15 APS DS3-L 240V FLOATING 30A 768W 3.2A 2x18A 60V 96.5% UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN DERATED(CEC)AC POWER 10,396W PERMISSION FROM CONTRACTOR IS IN DISCONNECTS OCPDS AND WILL BE SUBJECT TO CIVIL OF U.S.COPYRIGHT wWS 3 REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. QTY. RATED CURRENT MAX VOLTAGE DAMAGES AND PROSECUTIONS. SWi 1 SQUARED D222NRB OR EQUIV. 60A 240VAC CBI-3 3 20A 240VAC NEW PV SYSTEM: 11.600 kW F1-2 2 60A 240VAC F ASHRAE EXTREME LOW -10°C(14.0°F),SOURCE:AURORA STATE(45.25°;-122.77°) F LATT ASHRAE 2%HIGH 33°C(91.4°F),SOURCE:AURORA STATE(45.25°;-122.77°) • ■ RESIDENCE 14445 SW 87TH CT, BILL OF MATERIALS TIGARD,OR 97224 CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION 4 MODULE HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+400W PM1-29 29 PIECES 1 HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+400W 400W APN:2S111 AA0150D INVERTER APS DS3-L 11-15 15 PIECES 1 APS DS3-L 768W INVERTER DISCONNECT SQUARED D222NRB SWi 1 PIECE 1 SQUARED D222NRB,FUSED,2-POLE,60A,240VAC OR EQUIVALENT ENGINEER OF RECORD AC COMBINER PANEL GEN-AC-PANEL EP1 1 PIECE 1 AC SUBPANEL WIRING GEN-12-AWG-THWN-2-CU-RD WR1 135 FEET 1 12 AWG THWN-2,COPPER,RED(LINE 1) WIRING GEN-12-AWG-THWN-2-CU-BLK WR1 135 FEET 1 12 AWG THWN-2,COPPER,BLACK(LINE 2) WIRING GEN-8-AWG-THWN-2-CU-GR WR1 45 FEET 1 8 AWG THWN-2,COPPER,GREEN(GROUND) ■ WIRING GEN-6-AWG-THWN-2-CU-RD WR2-3 20 FEET 1 6 AWG THWN-2,COPPER,RED(LINE 1) ■ WIRING GEN-6-AWG-THWN-2-CU-BLK WR2-3 20 FEET 1 6 AWG THWN-2,COPPER,BLACK(LINE 2) WIRING GEN-6-AWG-THWN-2-CU-WH WR2-3 20 FEET 1 6 AWG THWN-2,COPPER,WHITE(NEUTRAL) WIRING GEN-6-AWG-THWN-2-CU-GR WR2-3 20 FEET 1 6 AWG THWN-2,COPPER,GREEN(GROUND) WIREWAY GEN-PVC-00.0.75"DIA WW1-3 65 FEET 1 PVC-00 CONDUIT,0.75"DIA OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC CBI-3 3 PIECES 1 CIRCUIT BREAKER,20A,240VAC 5 OCPD GENERIC MANUFACTURER GEN-FU-60A-240VAC F1-2 2 PIECES 1 FUSE,60A,240VAC PAPER SIZE:11-x IT(ANSI 8) TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB-4-4X JB1 1 PIECE 1 TRANSITION/PASS-THROUGH BOX,WITH 4 TERMINAL BLOCKS DESIGN TABLES DATE:07.06.2023 DESIGN BY: V.P. ■ ■ CHECKED BY: M.M. 6 REVISIONS E-602 00 A - B • C • D • E • F • G • H A • B . C • D • E • F • G • H Lii , . , ,-.., 4 --Y ELECTRICAL SERVICE ■ I LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE, CONTRACTOR CALIFORNIA FIRE CODE 605.11,OSHA STANDARD 1910.145,ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. UNITY ELECTRICAL SERVICE 2 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 0 0 PHONE: 1-360-559-8699 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8"AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED. 'DANGER"WILL HAVE RED I• •CA U T I N I ABBESS: 600 S 74TH PLACE,RIDGEFI BACKGROUND;'WARNING"WILL HAVE ORANGE BACKGROUND;"CAUTION"WILL HAVE ELD,WA 98684 YELLOW BACKGROUND.[ANSIZ535] POWER TO THIS BUILDING IS ALSO SUPPLIED ■ A\WA .. .., INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED FROM ROOF MOUNTED SOLAR ARRAYS WITH ■ LIC.NO.: UNITYES797CH ELECTRICAL SHOCK HAZARD RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED HIC.NO.: NORTH SIDE OF THE HOUSE TERMINALS ON THE LINE AND SWITCH FOR SAFETY DISCONNECTS AS SHOWN: ELE.NO.: SOLAR PV SYSTEM DIRECTORY UNAUTHORIZED USE OF THIS LOAD SIDES MAY BE ENERGIZED DRAWING SET WITHOUT WRITTEN IN THE OPEN POSITION PERMANENT PLAQUE DIRECTORY PROVIDING THE LOCATION OF THE SERVICEISDISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING PERMISSION ION FROM CONTRACTOR IN VIOLATION OF U.S.COPYRIGHT LAWS LABEL 1 LABEL 5 MEANS IF NOT IN THE SAME LOCATION(5 3/4"X 1 1/8"). AND WILL BE SUBJECT TO CIVIL 3 AT EACH DISCONNECTING MEANS FOR AT RAPID SHUTDOWN DISCONNECT SWITCH(5 1/4"X 2"). [NEC 690.56(B)] DAMAGES AND PROSECUTIONS. PHOTOVOLTAIC EQUIPMENT(2"X 4"). [NEC 690,56(C)(3)]. WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER,A [NEC 690.13]. DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV : NEW PV SYSTEM: 11.600 kWl SYSTEM DISCONNECTING MEANS. == PV ARRAY /\WARNING PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN FRONT = BACK F LATT BATHROOMS POWER SOURCE SOLAR PV SYSTEM [NEC 690.4(D),(E)] OUTPUT CONNECTION ■ DO NOT RELOCATE THIS EQUIPPED WITH mi RESIDENCE� �� ■ OVERCURRENT DEVICE PHOTOVOLTAIC POWER SOURCE �M MEM RAPID SHUTDOWN MEM == 14445 SW 87TH CT, LABEL 2 allillalli PV ARRAY MI- NEM AT POINT OF INTERCONNECTION TIGARD, OR 97224 OVERCURRENT DEVICE(2" LABEL 4"). LABEL 9 s [NEC 705.12(B)(2)(3)(B)]. AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING 4 SOLAR METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE MAIN DISTRIBUTION SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, ORFLOORS(5314"X11)8"). 3 M UTILITY DISCONNECT(INSIDE) APN:2S 111 AA01500 PHOTOVOLTAIC SYSTEM [CEC 690.31(D)(2)] N ENGINEER OF RECORD AC DISCONNECT - UTILITY METER POWER SOURCE TURN RAPID SHUTDOWN SWITCH TO 0 0 RATED AC AMPS THE"OFF'POSITION TO SHUT DOWN OUTPUT CURRENT PV SYSTEM AND REDUCE SHOCK ■ NOMINAL OPERATING 240 VOLTS HAZARD IN ARRAY AICAUTION TO PV ARRAY� ■ AC VOLTAGE LABELS LABEL6 MULTIPLE SOURCES OF POWER (N)AC LOAD CENTER- AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SYSTEM AT DISCONNECTING MEANS(4"X 3"). (3 3l4'X 5114"),[NEC 690.56(C)(1)(A)]. LABEL 10 [NEC 690.54] AT UTILITY METER(5 3/4"X 1 1/8") (N)AC DISCONNECT - /\WAR [NEC 690.56(B)] (E)UTILITY METER PAPER SIZE:11'x 17"(ANSI B) 5 PHOTOVOLTAIC SYSTEM DUAL POWER SUPPLY AWARNING SOURCES:PV SOLARTILITY CSIRAR CUIT BREAKER PLACARDS DISCONNECT ANDPVSOLAR CIRCUIT BREAKER r_7 ELECTRIC SYSTEM IS SAWED !, LABEL 4 LABEL8 AT EACH AC DISCONNECTING MEANS LABEL 7 AT POINT OF INTERCONNECTION X 1" AT POINT OF INTERCONNECTION DATE:07.06.2023 (4" )' (2 3/4"X 1 5/8"). (2"X 1'). (E)UTILITY ■ [NEC 690.13(B)]. [NEC 705.12(B)(3)] [NEC 705.12(BX3)] GRADE II BY: V.P. TD MEP CHECKED BY: M.M. 6 EQUIPMENT ELEVATION REVISIONS 01 NOT TO SCALE E-603.00 A • B • C • D • E • F • G H A ■ B • C ■ D • E • F • G • H D4 20 s-501 "� f _ )�� D5 1 ssoi ■ ®�® // u.... mu ......_._. ■ ELECTRICAL SERVICE r I © = O // - - CONTRACTOR 0 UNITY ELECTRICAL SERVICE 2 ` pd, RACKING DETAIL (LONGITUDINAL) GENERAL NOTES 99 ADRESS: 600S74TH6 PLACE,RIDGEFI D2 NOT TO SCALE ELD,WA 98684 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ■ �v� ■ LIC.NO.: UNITYES797CH HIC.NO.: D1 RACKING DETAIL (TRANSVERSE) U O.: UNAUTHORIZED THORIZED USE OF THIS NOT TO SCALE DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS 3 0 SHEET KEYNOTES AND WILL BE SUBJECT TO CIVIL U O DAMAGES AND PROSECUTIONS. 1. ROOF MATERIAL:ASPHALT SHINGLE NEW PV SYSTEM: 11.600 kWr T I I I I I I I I I I I I I I I I I l l l l l l l l l l l l l l l a 2. ROOF STRUCTURE:TRUSS 10 I I I I I I I I I I I I I I I I I o 3. ATTACHMENT TYPE:SUNMODO EZ ROOF MOUNT KIT F LATT I I I I I I I I I I I ..- I WITH L FOOT I I I I 1 I I I I ■ I I IL _ _ _ = I I I 4. MODULE MANUFACTURER: HANWHA Q-CELLS RESIDENCE I I I 5. MODULE MODEL:Q.PEAK DUO BLK ML-G10+400W • 6. MODULE LENGTH:74" I I I I I 14445 SW 87TH CT, O I 7. MODULE WIDTH:41.1" I I I I 21 8. MODULE WEIGHT:48.5 LBS. TIGARD,OR 97224 I I I I 9. SEE SHEET A-103 FOR DIMENSION(S) I Ir = 1 I 10. MIN.FIRE OFFSET:18"FROM RIDGE,36"FROM EDGE 4 I I I II 1 1 1 1 , ] r 1 1 1 1 I I I 11. TRUSS SPACING:24 IN.O.C. APN:2S111AAO1500 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 12. TRUSS SIZE:2X4 IN.NOMINAL ENGINEER OF RECORD I I I I I I I I I I I I I I 13. LAG BOLT DIAMETER:3/8 IN. 14. LAG BOLT EMBEDMENT:4 IN. 0 15. TOTAL#OF ATTACHMENTS: 71. - 16. TOTAL AREA:612.5 SQ.FT. ■ 17. TOTAL WEIGHT: 1573.96 LBS. ■ _ RACKING DETAIL (TOP) _ _ 18. WEIGHT PER ATTACHMENT:22.17 LBS. D3 • •••• • 19. DISTRIBUTED LOAD:2.57 PSF NOT TO SCALE ►���������������� ►������������� 20. MAX.HORIZONTAL STANDOFF:48 IN. 21. MAX.VERTICAL STANDOFF:IN ACCORDANCE WITH MODULE MANUFACTURERS INSTRUCTIONS. 6 � ^ 22. STANDOFF STAGGERING:YES PAPER SIZE II x I7 (ANsI B) 111.L23. RAIL MANUFACTURER(OR EQUIV.):SUNMODO j """` "_""__ 24. RAIL MODEL(OR EQUIVALENT): SMR100 ASSEMBLY DETAILS 25. RAIL WEIGHT:0.4126 PLF III , 1 26. MAX.TRUSS SPAN:N/A. DATE:07.06.2023 "`�`�`_i`�t_t`t� 27. MODULE CLEARANCE:3 IN.MIN.,6 IN.MAX. ■ hi.. ■ DESIGN BY: U.P. CHECKED BY: M.M. DETAIL (TRANSVERSE) DETAIL (LONGITUDINAL) REVISIONS 6 D4 NOTTOSCALE D5 NOTTOSCALE S-501 .00 A • B • C • D • E • F ■ G • H A . B . C . D . E ■ F . G ■ H ELECTRICAL SERVICE ■ Q. PEAK DUO BLK PEAK DUO BLK ML-G10+ SERIES ■ •Mechanical Specification CONTRACTOR M L-G10+ SERIES ocells Format 14G1r�II1 12E:n,inoudi oIramel �,•_ • I1519n >104ST32 mm1 Weight 48 51M[1.2 0591 2--''--- UNITY ELECTRICAL SERVICE Front Cover OM.,13.2moh"hermallo pm 5tressoo glass °s' �uw.... 'r"" 2 385-410W 1132 Cells 4.54 au rcfloolior te<hnJlcoy P Back Cover CUrVI,rslte Oct 20.9% Maximum Module Efficiency Frame 61a<kanodisenaln4nniom U PHONE: 1-360-559-8699 Celt 6.22"""°<lystallme°."NTUM 5nla.hall«115 -„.- ADRESS: 600 S 74TH PLACE,RIDGEFI Junction box 2093981 1262.3614.0A9 - e ISO 10'inn 32-60m4 r15 n8 rsrm.IPFJ,with aypass mocas r.n^^P-° ELD,WA 98684 Cable amm 50,er rani,f'1`499in(1250nm).to).-492'1(1250 m m) , . Connector 51.1503 MC4.IP68 4 511 m°.. xu,. •Electrical Characteristics ■ • LIC.NO.: UNITYES797CH POWER CLASS 3135 390 395 400 405 410 MINIMUM P_RFORMAN:EAT STANDARD TES CONDITIONS.5 C'(POWER TOLERANCE-SW-0tM HIC.NO.: Power at MPP' P ]W; 385 390 395 400 4G5 410 ELE.NO.: n n Breaking the 20%efficiency barrier Short Circuit Current' I. 1AI 11.04 nm 1110 11.14 nn 1120 UNAUTHORIZED USE OF THIS O ANT UM DUO Z Tech rology with zero gap cell layout Open Circuit Voltage' v,. IV] 45t9 45.23 4527 4530 4534 4537 DRAWING SET WITHOUT WRITTEN 000515_module ellciexy up to 20-9% Current atMPP LA; 1059 t0-65 loll 1077 10.83 10R9 PERMISSION FROM CONTRACTOR IS IN Voltage at MPP V,.. IV 36.36 36.62 3688 3713 3239 3764 VIOLATION OP U.S.COPYRIGHT LAWS Efficiency' r i%] >196 >19.9 >20.1 L20.4 >20.6 >20.9 AND WILL BE SUBJECT TO CIVIL 3 f1.ZJ A reliable investment DAMAGES AND PROSECUTIONS. 1� ,nrlr [25 year U c _Il artty and 25-Veer ineOr to NIM,M VLNCON.)11 FMAN(;L AI NORMALOVERAI 40 CONONS.Sue1- WomneOp oenom.ncewanam} Power at MPP P... Iw] 288.8 292.6 2963 3001 303.8 307.6 NEW PV SYSTEM: 11.600 kWF �• Short Circuit Current I 'IAI 8.90 8.92 8.95 8.92 9.00 9.03 Open Circuit Voltage 'VI 4262 4265 42.69 4272 4276 42.79 FLATT Enduring high performance c MPP Aj 8.35 481 846 851 6v 3546 662 V It g [MPP '. V 34.59 341 3603 3425 3568 Long-tefrn yield security with Ant'.LPTID Ted to pgy Mr asr rc'r..talc t c - V -5 r et SIC 1000 W m 15-2'C.AM 1 S accorh:n>IO AC60904 3•'800 V,co NMUUl s:)r< r AM".S oealB Anti PIP Technoio9y'arts Hot Spot Protect. ■ RESIDENCE ■ �'� Omits PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ....✓ w _-.-. - w Extreme weather rating sea'T:. a dUring 14445 SW 87TH CT Hlg t tuct alo-nr Jr) I o)ralr=.-adihed for ps a a t ce year wAr x w"1 935V,, lnom c 1 highsn0w(5400Pa)and wino loads'4000Pa1. et to, .4ue ,e6.Pr e ups 35 yearn TIGARD,OR 97224 .5 4Ii data w:rn:r meesrtemem Innovative all-weather technology 1 h ' 'in a min rank 4 Optimal yields,whatever the weather with excclic re low fight o oz , n o I5 r rm_o e no wo tao and temperature behaviour. ea Pr Pryor pecnve A PAT,2S111 A A01 COo 6 busbar 12 busbar I1L-�IYY LJ rtr'1 J cell technology re.I technology Stywain 9 l0 "mr o moon m succor•: /� -,p e.,.r.,,n.. �..o. . o,o ENGINEER OF RECORD / 1 The most thorough testing TEMPERATURE COEFFICIENTS \N programme in the industry Temperature Coefficient of 0 t: -004 Temperature Coefficient of V, 02' Ocdls is the firsts Jule rl44'04dwel to pass the Temperature Coefficient of PM„ , 4,K 034 Nominal Module Operating Temperature NMOI 00 109 a roost comprehens-ve qua1114 plogl ammo III the Industry The 43 3 I new"Qua en'Controlled PV-o'the Independent ceilificabOO •Properties for System Design ■ institute TUY Rheinland- ■ Maximum System Voltage V IV 1000(WCi'10901UL) PV module clessrtcation Class II Maximum Series Fuse Rating A BC or Fire Rating based on ANSI/ILL 61730 x Max.Design Load,Push/Pull'- IIb 9Y-: 750600 Pa" ,J650 Pa, Permitted Module Temperature -42R A IAr n luv nr. 11 �61a1 -rrhatlH h,�V.95 Max.Test Load,Push/Pulp III-0 It.. 11315400 P38440)0P:,, on Continuous Duty ° Sc, Inse n(I3f Men.e •Qualifications and Certificates UI e173o cc onr44con1 Ouarive mulled P5 TUV PIR.1 Im+ci 1 5 sec Patent1215 NO lees➢15 me SPe C /5 PAPER SIZE:11"x 1T(ANSI B) l.5-Pt Patent NO 9,a932151 r• E L 1 d J5 MEM l The ideal solution for. ,.•„ °',. RESOURCE DOCUMENT ou M .O Z,1 Rooftop arrays or aPVn ' residential buildings p fA o •• ,a,,..• DATE;07.06.2023 0cells pursues nnnirnlzlriy paper output In consldcration of the global environment ■ mpsor'''m ��p .<,.9,''''''r ,�ae4assw 9.w9ra rem n 9rer.ren ocells DESIGN BY: V.P. ■ CHECKED BY: M.M. 6 REVISIONS A wB C el D . E mg F • G is H R-001 .00 A . B ■ C ■ D . E ■ F . G • H UNITY ELECTRICAL SERVICE ■ - ■ 0 i APsystems Leading the Industry in Datasheet • I DS3 Microinverter Series • ALTENERGY POWER Solar Microinverter Technology CONTRACTOR Model - Input Data(DC) UNITY ELECTRICAL SERVICE 2 Recommended PV Module Power(STC)Range 250Wp-480Wp+ 265Wp-570Wp+ 300Wp-660Wp+ DS 3 Series Peak Power Tracking Voltage 22V-48V 25V-55V 32V-55V PHONE: I-360 559 6699 Operating Voltage Range 16V-60V 16V-60V 26V-60V The most powerful Dual Maximum Voltagenput page Gov ADRESS: 600 S 74TH PLACE,RIDGEFI ' i Microinverter Maximum Input Current 16A x 2 18A x 2 20Ax 2 ELD,WA 98664 I • One microinverter connects to two solar modules Output Data(AC) I • Max output power reaching 640VA,768VA or 880VA Maximum Continuous Output Power 640VA 768VA 880VA . LIC.NO.: UNITYES797CH �, • Two independent input channels(MPPT) Nominal Output Voltage/Range` 240V/211V-264V HIC.NO.: • CA Rule 21(UL 1741 SA)compliant Nominal Output Current 2.7A 3.20A 3.7A 9 ELE.NO.: ,I • NEC 2020 690.12 Rapid Shutdown Compliant Nominal Output Frequency/Range` 60Ht/59.3Hz-60.5Hz i • Encrypted Wireless Zigbee Communication UNAUTHORIZED USE OF THIS r /�_ Power Factor(Default/Adjustable) 0.99/0.7 leading...0.7 lagging DRAWING SET WITHOUT WRITTEN • Phase Monitored and Phase Balanced Maximum Units per 20A and 30A Branch" 6/8 5/7 4/6 PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS AC Bus Cable 12AWG/10AWG AND WILL BE SUBJECT TO CIVIL 3 DAMAGES AND PROSECUTIONS. Efficiency Peak Efficiency 97% NEW PV SYSTEM: 11.600 kWl Cost anal Efficiency 99.5% F LATT Nominal MPPT Efficiency 99.5% PRODUCT FEATURES Night Power Consumption 20mW APsystems 3rd generation of dual microinverters are reaching unprecedented power outputs of 640VA or 768VA or 880VA to MI Mechanical Mechanical Data ■ adapt to today's larger power module.With 2 independent MPPT,encrypted Zigbee signals,the DS3-5,O53-L and DS3 benefit Operating Ambient Temperature Range -40°F to+149°F(-40°C to+65°Cy from an entirely new architecture and are fully backwards compatible with the D51 and YC600 microinverters, g TemperatureRange a Ran a -40°F to+185°F(-40°C to+85°C) 14445 SW 87TH CT, The innovative and compact design make the product lighter while maximizing power production.The components are encapsulated with silicone to re- Dimensions(We H x D) 10.3"x 8.6"x 1.6"(262mm X 218mm X41.2mm) TIf'ARD,OR 97224 duce stress on the electronics,facilitate thermal dissipation,enhance waterproof properties and ensure maximum reliability of the system via rigorous Weight 5.71bs(2.6kg) testing methods including accelerated life testing.A 24/7 energy access through apps or web based portal facilitate remote diagnosis and maintenance. DC Connector Type MC4 The new D53 series is interactive with power grids and fully compliant with CA Rule 21 requirements,to better manage photovoltaic power spikes in Cooling Natural Convection-No Fans [� 4 Enclosure Environmental Rating NEMA 6 APN.2S111AA01500 the grid.With a performance and an efficiency of 97%,a unique integration with 20%less components,APsystems DS3-5,053-L&D53 area game changer to residential and commercial PV. ENGINEER OF RECORD Features Communication(Inverter To ECU) Encrypted ZigBee Isolation Design High Frequency Transformers,Galvanically Isolated WIRING SCHEMATIC Energy Management Energy Management Analysis(EMA)system Warranty--' 10 Years Standard;25 Years Optional ■ I I...... msaamis a ..... inmosseCompliance ....... m. ■ .... 8 8...... .... .. ...••.. ........ .......• Safety and EMC Compliance UL1741;CSA C22.2 No.107.1-16;CA Rule 21(UL 1741 SA);FCC 111111111■111111■ .pm�.■.■.. .�.N.. Part15;ANSI C63.4;ICES-003;IEEE1547;NEC2014&NEC2017 Section ■ .. ...N. 690.11 DC Arc-Fault circuit;Protection NEC2014&NEC2017 Section ....MO .a.... .. ...■.... �������� gillinleilifin Y...... ..tMN= 690.12 Rapid Shutdown of PV systems on Buildings;NEC 2020 ..••N•• ••.�...■ • •.!■•• • ■ N.• •Nammgl voltage/frequency range am be extended beyond nominal if require dbv the utility ®nil Nights Reserved 5 !!� -__ ��� a■• -gismo ^omits moo vary Refer to localreguuements to define the number ofmicrornverters per branch sprcifimhts Reserved Menge without onrrplease ensure you we using the PAPER SIZE:11"it T'(ANSI B) n r u u inyaurareo. most recent WIMP found or web uA Psi SPm 1�1 Lt tt Il , • '•h be MA portale ileasereormnty,APsystemsty I'Ms amiable need erabemonnara Ell xarheel�portalPtiewarrertoourwarmnrolcro aynbbleana,a.mP,,itore m. RESOURCE DOCUMENT I - APsystems Meets the standard requirements 600 Frickser Ave NE Suite 200 Seattle.WA 98110 So a tour 13Mbuted Energy tified ourre5 5____________Hil Te 844-6667C3S uuenhtaryenuned with the DATE:07.06.2023 apsystcrns rant c us CSADESIGN BY: V.P. . 2021/08/28 Rev1.1 • CHECKED BY: M.M. REVISIONS 6 Q�OO�.00 A • B • C • D • E • F • G • H I \ A B •• C D a E ■ F ■ G •� H 1 u hi ■ 5IINM Cut Sheet ■ ELECTRICAL SERVICE SMR100 Rail SMR1 00 Rail CONTRACTOR L L UNITY ELECTRICAL SERVICE 2 PHONE: 1-360-559-8699 ADRESS: 600 S 74TH PLACE,RIDGEFI i...•_s `" ELD,WA 98684 • Z • LIC.NO.: UNITYES797CH HIC.NO.: ELE.NO.: UNAUTHORIZED USE OF THIS ,am DRAWING SET WITHOUT WRITTEN w n PERMISSION FROM CONTRACTOR IS IN - VIOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL 3 Mechanical Properties Section Properties DAMAGES AND PROSECUTIONS. Material:6005-T5 Aluminum Sx:0.196 in'(3.21 cm3) NEW PV SYSTEM: 11.600 kWr Weight:0.4126 Ibs/ft(0.614 kg/m) Sy:0.146 in3(2.39 an') F Ultimate Tensile Strength:37.7 ksi(260 MPo) Area(X-section):0.352 in'(2.27 cm SMR200 Rail Yield Strength:34.8 ksi(240 MPa) F LATT ■ SMR200 Rail RESIDENCE 14445 SW 87TH CT, 7 _3L TIGARD,OR 97224 j\._ 4 J gm 14. • APN:2S111AA01500 ENGINEER OF RECORD hoes Ma DI 5 Part Number Description Mechanical Properties Section Properties PAPER SIZE:1Pxt7"(ANSB) A204 2 2-1 68-BK SMR100 Rail,Black Anodized, 168" Material:6005-T5 Aluminum 5x:0.223 in'(3.74 cm3) RESOURCE DOCUMENT 1 Weight:0.453 Ibs/k(0.626 kg/m) Sy:0.189 in3(3.10 cm3) Ultimate Tensile Strength:37.7 ksi(260 MPa) Area(X-section):0.388 ins(122 cm1 A20431-168-BK. SMR200 Roil,Black Anodized, 168' I Yield Strength:34.8 ksi(240 MPo) DATE:07.06.2023 A20440-BK1 SMR1 00 Roil End Cap,Black DESIGN BY: V.P. ■ ■ A20446-BK2 SMR200 Roil End Cap, Block D10225-tout CHECKED BY: M.M. Dimensions shown are inches land millirnetersl Details are subied to change without notice 6 REVISIONS A • B isC • D • E ' F • G • H R-003.00 A • B • C • D • E • F • G ma H SUNM ELECTRICAL SERVICE MI II INSTALLATION O MADE CONTRACTOR UNITY ELECTRICAL SERVICE 2 PHONE: 1-360-559-8699 Ez & EzR! ADRESS: 600 S 74TH PLACE,RIDGEFI ELD,WA 98684 ■ • LIC.NO.: UNITYES797CH 4 HIC.NO.: ELE.NO.: EZUNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUBJECT TO CIL 3 \ E DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 11.600 kWF l FLATT t. ' • RESIDENCE 14445 SW 87TH CT, TIGARD,OR 97224 4 SunModo's best-selling APN:2S111AA01500 EZ Roof Mount is the industry ENGINEER OF RECORD standard for PV system The EZ & EZR Advantage mounting on any composite J Leak-proof design protects ■ ■ shingle roof. sealing points from elements. ✓ ICC Certified for both rafter and Now, SunModo introduces a decking solution. 5 smaller footprint, EZR Roof PAPER SIZE:11'x 17•(ANSI B) ✓ Exceptional resistance to corrosion Mount flashing, where truss and wear. RESOURCE DOCUMENT anchoring can be assured, ✓ A wide variety of L-feet and DATE:07.06.2023 embossed design minimizes standoffs available. DESIGN BY: V.P. • bending, and only one tool • is nee. d. J Surprisingly easy to install! CHECKED BY: M.M. 6 REVISIONS R_004.00 A • B • C • D • E i• F • G • H