Loading...
Plans (56) ....._ PHOTOVOLTAIC ROOF MOUNT SYSTEM RECEIVED �28 MODULES ROOF MOUNTED - 11.340 kW DC, 11.520 kW AC, 16549 SW DARWIN LP, TIGARD, OR 97224 JUN 0 5 2023 infinity so I or CITY OF TICARD INFINITY HOME SOLUTIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SITE DETAIL: SHEET INDEX: BUILDING DIVISION VANOOUVEIR WA 98661 SYSTEM SIZE: 11.340 KW DC UTILITY: PORTLAND GENERAL ELECTRIC PV 0.0: GENERAL NOTES AND PROJECT DATA DS 07: WIRING SPECIFICATION PHONE:1-8004184598 11.520 KW AC MSP: EXISTING 225A WITH 200A MAIN BREAKER PV 1.0: PLOT PLAN DS 08: MOUNTING-DATA SHEET INFINITY SOLAR.COM MODULE TYPE&AMOUNT: (28)ZNSHINESOLAR ZXM7SH108-405M ROOF MATERIAL: COMPOSITE SHINGLE PV 1.1: SITE PLAN DS 09: RACKING-DATA SHEET MODULE DIMENSIONS: (UW/H)67.87"/44.64"/1.18" ASCE 7-10 WINDSPEEDS: (3 SEC GUST IN MPH) PV 1.2: ROOF SECTION DS 10: RACKING-GROUNDING REVISIONS INVERTER: (15)AP SYSTEMS DS3-L RISK CATERGORY I: 100 IM 1.0: INVERTER MAP DS 11: RACKING-CERTIFICATION Description Data Rev INTERCONNECTION METHOD: LINE SIDE TAP RISK CATEGORY II: 110 S 1.1: MOUNT DETAILS AHJ: CITY OF TIGARD RISK CATEGORY III-IV: 115 E 1.1: 3-LINE DIAGRAM RACKING: GRASOL RACKING SYSTEM FOR COMP ROOF E 1.2: NOTES GOVERNING CODES: ARRAY AREA: 21.04 SQFT x 28=589.1 SQFT E 1.3: WARNING LABELS s, DS 01: PV MODULE SPECIFICATION SHEET 2010 OREGON SOLAR INSTALLATION SPECIALTY CODE DS 02: MICROINVERTER SPECIFICATION SHEET -.- ""_. Signature with Seal 2022 OREGON STRUCTURAL SPECIALTY CODE(OSSC) DS 03: COMBINER PANEL CERTIFICATION 1411 2021 OREGON ELECTRICAL SPECIALTY CODE(NEC 2020) 2022 OREGON FIRE CODE (R DS 04: AC DISCONNECT UL CERTIFICATION , DS 05: AC DISCONNECT UL CERTIFICATION DS 06: JUNCTION BOX UL CERTIFICATION PHOTOVOLTAIC NOTES: 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL WITH THE"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING k C Project Name& DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK SYSTEMS. J. # `, W Address UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING C) PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) CONSIDERATION OF a"P AND MP BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE Z 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC =°- a THREAD-LESS COMPRESSION TYPE. LATERAL FORCE DETERMINATION. ) , ,1r„,' Cl) 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB CC 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. . _ a DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS, 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING .; + d t1 c ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR a Q -I v in WITHSTAND THE WEATHER. DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE .1 ° . Z N v� 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE it, 0 > rn rn APPROPRIATE WATER RUN OFF. AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A "'", g Q Et m? 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. ,/ p O 0 o BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW �tALIDU Tv r 1 OF ' 'a k d , n Z a C Q 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. ^(' `' LLI co w ". 2 THE ISSUANCE OF A PERMIT rn ¢ w L. 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.6 01,310.8 D) a � C7 Z BASED ON CONSTRUCTION 2 SATELLITE VIEW z I- 0 APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DOCUMENTS AND OTHER � � d 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE DC SIDE OF THE SYSTEM.(NEC 250.97) PV 0.0 SCALE:NTS WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF DATA SHALL NOT PREVENT _ MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM.(NEC 690.34) SMALLER THAN#6 COPPER WIRE.(NEC 250.64 B) THE CODE OFFICIAL FROM Y 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) REQUIRING THE CORRECTION`': QFi'�j' oo UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING-ELECTRIC SHOCK HAZARD. 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC 250.64(E) OF ERRORS. ORSC 105.4 . _ o y v THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND(NECE 690.35(F)) A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PEE PHASE AND SYSTEM PER -, r Sheet Name �,EsGr�Bows ro. GENERAL NOTES FROM ANY PHYSICAL DAMAGE. NEC210.5. HBOA r 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. Approved p1 !OS'= AND PROJECT 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. 33,DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR A ,shall be on job ei 12- 14.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC 93.690.31(E) " - Ti Ti. DATA 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, Kinton Sheet Size COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED JUNCTION&PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S - CITY RD 1110 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE INSTALLATION INSTRUCTIONS LAMC 93.690.110.3&93.110.3(B). OF ('`� ANSI B CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE P.F VT 1 \V'1 T) TT O 1 -ODE COMPLIANCE - ,.-"'a 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY STAINLESS STEEL LAMC 93.110.3(B). 11 e X 17" ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE A p17 ro cd: r 7 APPROPRIATE. LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. 1'i': r , Sheet Number 0 l J 18.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS t SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY IA 1 i t #r: J k MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN REMOVABLE FASTENERS. �� u�A�'�1 ` PV O'O T>' THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM 38.REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE A.;i,:)I es 5: `I4 S l L S W Npadit.1 L`),\ REQUIRED BY THE ARCHITECT/ENGINEER. BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC Stitt' . 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. ' - OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING By: /1 - Date: (� �, 2 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING 7SIIf 1 ( l� r: 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE ROOF-COVERING MATERIAL. CD GENERAL NOTES AND PROJECT DATA40.ALLROOFMOUNTEDCONDUITWILLBEAMINIMUM1/2 OFF THE ROOFSURFACE. (3-- VICINITY MAP \PV00 / SCALE:NTS PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 28 MODULES-ROOF MOUNTED - 11 .340 kW DC, 11 .520 kW AC, 16549 SW DARWIN LP, TIGARD, OR 97224 Infinity solar INFINITY HOME SOLUTIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: PROOF ACCESS POINT 6405E MILL PLAIN VANCOUVER WA 98881 62-9" PROPERTY LINE ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS PHONE:1-800-81&0.598 SYSTEM SIZE: 11.340 kW DC z - - - - - - - _____ - - - - THAT REQUIRE THE PLACEMENT OF GROUND LADDERS INFINYTYSOLAR.COM 11.520 kW AC OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND MODULE TYPE&AMOUNT: (28)ZNSHINESOLAR ZXM7-SH108-405M LOCATED AT STRONG POINTS OF BUILDING REVISIONS MODULE DIMENSIONS: (UW/H)67.67"/44.64"11.18' w I'' r- CONSTRUCTION IN LOCATIONS WHERE THE ACCESS De Date INVERTER: (15)AP SYSTEMS DS3-L O I POINT DOES NOT CONFLICT WITH OVERHEAD AHJ: CITY OF TIGARD a ' I OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. I 1 NEW PV AC DISCONNECT VISIBLE, LOCKABLE, LABELED DISCONNECT I' PATIO I Signature with Seal WITHIN 10'OF UTILITY METER —1 !I ROOF#4 Project Name& 3'-$" 1 (02)ZNSHINESOLAR ZXM7-SH108-405M (Address SLOPE:29° w I AZIM.:0° Z w I 1 0 I 1 . Ct w a. I i a o '� Z N LS) _O ( I Lo > rn rn Q co 1 MAIN HOUSE, 1 , f---- FENCE z 0 0 r)-I I Z LO I o w ROOF#1 �jl r ---- - -- --- J ____.• uO (09)ZNSHINESOLAR ZXM7-SH108-405M I z fO SLOPE:36° 1 - [ AZIM.:270° 1 'r I I Q I ROOF#3 > EXISTING INTERIOR MAIN SERVICE I j (06)ZNSHINESOLAR ZXM7-SH108-405M SLOPE:36° PANEL TIED TO EXTERIOR UTILITY 1 Sheet Name METER#38195142 I Liz AZIM.:90° 1 z PLOT PLAN OM ROOF ACCESS POINT 1 !/ GARAGE Sheet Size 1 I I rL r - - ANSI B N I I 11"X17" r' DRIVEWAY I /\N. Sheet Number LL ' L - �� N PV 1.0 L - - - - PROPERTY LINE 50.-0" ' — — ROOF#2 FRONT OF HOUSE (11)ZNSHINESOLAR ZXM7-SH108-405M 1 PLOT PLAN 16549 SW DARWIN LP ,ME129° PV 1.0 SCALE:3/32"=1-0" PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS MODULE, ARRAY WEIGHT(LOAD SYSTEM LEGEND SYSTEM SIZE: 11.340 KW DC NUMBER OF MODULES 28 ZNSHINESOLAR ZXM7SH108-405M CALC'S) EXISTING INTERIOR MAIN SERVICE PANEL&POINT C 11.520 KW AC NUMBER OF INVERTER 15 AP SYSTEMS DS3-L Number of Modules 28 M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY MODULE TYPE&AMOUNT: (28)ZNSHINESOLAR ZXM7SH108-405M EATON BR STYLE 1-INCH LOAD CENTER Module Weight 45.19 LBS METER#38 195 142. infinity SOIL r MODULE DIMENSIONS: (LIW/H)67.87'/44.64"I1.18" COMBINER PANEL 1 816L125RP INVERTER: (15)AP SYSTEMS DS3-LTotal Module(Array)Weigh 1265.32 LBS n NEW VISIBLE,LOCKABLE,LABELED DISCONNECT NFINITY HOME SOLUTIONS AC DISCONNECT 1 60A FUSIBLE AC DISCONNECT,240V Number of Attachment r "I LOCATED WITHIN 10'FROM THE UTILITY METER 6405EMILI PLAIN AHJ: CITY OF TIGARD NUMBER OF ATTACHMENTS 101 GRASOL GS-10 RAIL ATTACHMENTS paint 101 VANCOUVER WA 98661 18-0598 Mounting System Weight I�I PHONE 1�OL 6RCOM RAILS 19 GRASOL RACKING SYSTEM (Per Module) 1.5 LBS 1 I NEW DEDICATED PV SYSTEM COMBINER PANEL INFINITY sOLAR.GOM VISIBLE, LOCKABLE, LABELED DISCONNECT RAIL SPLICE 8 SPLICE KIT Mounting System Weight 151.50 LBS ' 1 REVISIONS WITHIN 10'OF UTILITY METER MID CLAMPS 36 MID CLAMPS/UFO Total System Weight 1416.82 LBS 28 NEW ZNSHINESOLAR ZXM7-SH108-405M MODULES Der:moon Date Rev (Motile " END CLAMPS 40 END CLAMPS/STOPPER SLEEVE Weight at Each Attachment Point I �1 WITH NEW(15)AP SYSTEMS DS3-L INVERTERS. NOTE : GROUNDING LUG 10 GROUNDING LUG 12.53 LBS ATTIC RUN-YES (Array wcigM�Rwnbe/alAtta4imeM PoedJ ATTIC AN- ROOF#04 Module Area(67.87"x44.64') 21.04 SqFt SHUTDOWNFAN -NON Total Array Area 589.11 SgFt 7. =FIRE PATHWAY Distributed Load 2.22 per SgFt 9 Si nature with Seal I (arrsvabmWa'WlrrdaUaw Me) ❑O =ROOF OBSTRUCTIONS I 1 I 1 I Total Roof Area 2496 SqFt O I Total Percentage or Roof Covered 23.60% • =ATTACHMENT POINTS __- Ta&Mey Area/Total Roof*W100 1 =RAFTER Project Name& 7:- \ 1 . ,_, - Address t --- =RACKING SYSTEM U co \ 1 I ----- L o N Z w \ I 1 I ---- - = ATTIC RUN 0 • • 1 ,� =CONDUIT ATTIC RUN JUNCTION BOX 1 1 \ ', I i n t I , 1 I ---- -- tj y ++ , - Q v coin T T T _- __ _ ___ : W Z N ROOF SECTIONS Q o 0 0 0 Li I I I I 1f� z 0-=a LL �2"FIRE S BACKI I _ '� ROOF#01 MODULE-09 w u3 CC o + + O 12"FIE BA K _ r I- SLOPE Q CD z w cc 1..--. I I 1 ❑ i 4 Z AZIMUTH-270° O • • I • I I I I w Zco 1 I 1 ❑ -_. MATERIAL COMPOSITE SHINGLE L.L' r 0_ I I ❑ 12"FIRE SETBACK �. 9 _ 0.- RAFTER SIZE&SPACING-7X4"@ 24'O.C. i ' I ' _ R SLOPE-29° Y It + ❑ o _ cr •-- ¢ AZIMUTH-180' • • • m - _ Q 37 3/ ' N 0_ C MATERIAL-COMPOSITE SHINGLE f1 1 t :I tI I I I n ¢ -^ ? CO4 RAFTER SIZE&SPACING-2"X4"@ 24'O.C. > )1 f i f w 1 I. _I.. rez wnl, w ROOF#09 MODULE-06 li I I I I u ' , i,/,'{ � I �;� - Z SLOPE-36' It y / / ❑ 1 Li1� //f AZIMUTH-90' Sheet Name f I i I !LL / /� / E ' l / MATERIAL-COMPOSITE SHINGLE NEW AC COMBINER PANEL I• • i • �I- 7 ,/: 6/ s' 1 i j ''I --- RAFTER SIZE&SPACING-2'X4"c24'0.C. SITE PLAN NEW PV AC DISCONNECT GROUPED �/ ROOF#64 MODULE-02 WITH SERVICE EQUIPMENT(VISIBLE, `kt i t � SLOPE-29° LOCKABLE,LABELED) C -f f f ---- AZIMUTH--° sheet size I'— 1 ` RAFTER SIZE&SPACING- X4MATERIAL-COMPOSITE L@24'O.C. ANSI B EXISTING INTERIOR MAIN SERVICE PANEL p I _ I X 7° &POINT OF INTERCONNECTION.TIED TO AC i I I EXTERIOR UTILITY METER#38 195 142 O M -- NOTE :- ROOF#02 ROOF ATTACHMENTS SHALL BE SPACED NO Sheet Number GREATER THAN 24 IN. OC IN ANY DIRECTION N PV 1 .1 I WHERE LOCATED WITHIN 3FT. OF A ROOF NOTE: = EDGE,HIP, EAVE OR RIDGE(OSISC 305.4.3) ALL PLUMBING AND FLAT VENT WILL c CIRCUIT(S) BE RELOCATED OR REMOVED PRIOR TO FRONT OF HOUSE ( � INSTALLATION ;/ %'-/,/,',/ CIRCUIT#1 -09 MODULES WITH 05 MICROINVERTERS 16549 SW DARWI N LP ( 1-\ SITE PLAN ////A/ CIRCUIT#2-09 MODULES WITH 05 MICROINVERTERS PV t.l 1 SCALE:1/8"=1'-0" %//////, CIRCUIT#3- 10 MODULES WITH 05 MICROINVERTERS ROOF 1 SII WEST SIDE (LI)PVMODULE �'-6' "� -``T-6" 2'Xd'TRUSS @24'O.C. Infinity solar rt111111°.- T INFINITY HOME SOLUTIONS ` T-� VA 0 6405E MILL PLAIN NCOUVER WA 98661 10'-6' PHONE:1-800818-0598 �' ,T INFINITY SOLAR.COM J 8�. �, T;4' T-0' -'.'.$= REVISIONS - ;•-� ', -0I - Description Date Res • "°°' '.11 .m.i...11111.111MIMMill " S Signature with Seal ROOF SECTION EXT EXTERIOR BEARING WALL ERIOR BEARING WALL Project Name& Address W -air. 0 (N)PV MODULE F-,-' _., W ROOF 1in ii� 8-0 co EAST SIDE 2'X4'TRUSS @24'DC. LLI CC (NIPV MODULE $.-0r"04" �•°� - -0" C 920" -� Z N I� r o ,d-to• tq-fa T-ia • ipI .CO ROOF SECTION `E7(TERIOR BEARING WALL EXTERIOR BEARING WALL J Sheet Name ROOF SECTION Sheet Size ROOF 1 2'X4'TRUSS @21'O.C. 2'X4'TRUSS♦�24'OC. ROOF 3 %':,54-2'. 7 r -'. '-0 ANSI B .Z-4r (N)PV MODULE � lif (N)PV MODULE 1.1R y IT 04-- ^ ''$-0,I ' -;.'0° ,, Sheet Number 5=0" 5'�0 PV 1.2 ROOF SECTION ROOF SECTION //f " 1 ROOF SECTION EXTERIOR BEARING WALL EXTERIOR BEARING WALL ��,.z� N 0 1 13 infinity solar N I INFINITY HOME SOLUTIONS 6405E MILL PLAIN I VANCOUVER WA 98661 PHONE:1-800-818-0598 INFINITY SOLAR.COM 2 14 REVISIONS 0esenptlon Date Rev 3 15 Signature with Seal 4 16 Project Name& Address 11 5 17 0 Z w i...... ............. p w CC 6 18 EL 0_ Q J 7 19 LI a 8 20 Q 1 1 9 21 Sheet Name _ INVERTER MAP 1 11 - - 10 22 Sheet Size ANSI B 11" X 17" Sheet Number 11 23 IM 1.0 L 12 24 1 INVERTER MAP DTU/ECU: IM 1.0 GENERAL STRUCTURAL NOTES: PV MODULE 0 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE GRASOL RACKING SEE(2/S 1.1) FOR `�/ infinity solar SYSTEM WITH GRASOL GS-10 MOUNT ENLARGED VIEW ATTACHMENTS.THE MOUNTING FEET ARE TO BE INFIN640f1Y 5EMI HOME LL PLA SOLUINTIONS ::....� SPACED AS SHOWN IN THE DETAILS, AND MUST VANCOUVER WA 98661 BE STAGGERED TO ADJACENT FRAMING PHONE:1-800-818-0598 �� INFINITY SOLAR.COM MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. / _---// 2. UNLESS NOTED OTHERWISE, MOUNTING \ REVISIONS �� ANCHORS SHALL BE 1/4" LAG SCREWS WITH A / � xq. U S�S(�Zq"OC o vho" Date R� MINIMUM OF 3" PENETRATION INTO ROOF ZR S FRAMING. ' 2" 3. THE PROPOSED PV SYSTEM ADDS 2.5 PSF TO THE ROOF FRAMING SYSTEM. (E)COMPOSITE SHINGLE ROOF 4. ROOF LIVE LOAD=20 PSF TYPICAL,0 PSF UNDER Signature with Seal NEW PV SYSTEM. J 5. GROUND SNOW LOAD=N/A PSF 6. WIND SPEED=110 MPH 7. EXPOSURE CATEGORY=C 8. RISK CATEGORY=II Project Name& Address W U Z W 1I ATTACHMENT DETAIL (SIDE VIEW) w \ ct s 1.1 / SCALE:NTS a ,:,_ v 1: Z N Q N CO CC � N 1.— SOLAR MODULE g a cn "• % Z � 0 � w co / % z LO i 0 GRASOL GS-10 RAIL = CO a , v-:\- 5 Sheet Name GS-FK-02 305MM ROOF FLASHING-,iiiiiiiiporr 100 .0001111111111.111111. BUILDING STRUCTURE MOUNT DETAIL Sheet Size ANSI B 11" X 17" Sheet Number ROOF - S 1.1 1/4" X 3" SS LAG SCREW 2.5" MIN. EMBEDMENT 1'2i ATTACHMENT DETAIL ENLARGED VIEW 1 s t. SCALE:NTS PV MODULE RATING @ SIC MICROINVERTERS SPECIFICATION Rooftop conductor ampacities designed in compliance with THIS PANEL IS FED BY MULTIPLE SOURCES MANUFACTURER ZNSHINESOLAR ZXM7SH108-405M MICROINVERTER MAKE AP SYSTEMS art. 690.8, Tables 310.15(B)(2)(a),310.15(B)(3)(a), (UTILITY AND SOLAR) V MICROINVERTER MODEL NO. DS3-L 310.15 B 3 C ,310.15 B 16 , Chapter 9 Table 4,5, &9. infinity solar MAX.POWER-POINT CURRENT(IMP) 13.03 AMPS MAXIMUM AC OUTPUT 768 W ( )( )( ) ( )( ) p AC OUTPUT CURRENT 48A MAX.POWER-POINT VOLTAGE(VMP) silo VOLTS Location specific temperature obtained from ASHRAE 2017 MAX INPUT VOLTAGE so V data tables NOMINAL AC VOLTAGE 240V INFINITY5HOMILL SOLUTIONS OPEN-CIRCUIT VOLTAGE(VOC) 37.30 VOLTS MAX AC CURRENT 3.20 A VANCOUVER WA 98661 SHORT-CIRCUIT CURRENT(ISC) 13.77 AMPS MAX OUTPUT VOLTAGE 240 V RECORD LOW TEMP -19°C 120% RULE PHONE 1-80 0 81 8-05 98 INFINITY SOLAR.COM NOM.MAX.POWER AT STC(PMAX) 405 WATT VISIBLE, LOCKABLE, LABELED DISCONNECT AMBIENT TEMP(HIGH TEMP 2%) 33°C BUS BAR RATING X 120%) -MAIN BREAKER RATING MAX.SYSTEM VOLTAGE _ 1500V WITHIN 10' OF UTILITY METER CONDUIT HEIGHT 0.5" = MAX. PV OCPD REVISIONS Description Dee Rev VOC TEMPERATURE COEFFICIENT -0.29°/0/°C ROOF TOP TEMP 55°C o NOTE: (225A x 120% -200 = 70A CONDUCTOR TEMPERATURE RATE 90°C ATTIC RUN-YES POINT OF INTERCONNECT,SUPPLY SIDE (28)ZNSHINESOLAR ZXM7-SH108-405M SHUTDOWN- NO EXISTING 240V/225A BUS BAR RATING, (15)AP SYSTEMS DS3-L INVERTERS MODULE: (28)ZNSHINESOLAR ZXM7-SH108-405M MAIN SERVICE PANEL,SINGLE PHASE, Signature with Seal BRANCH 1-09 MODULES WITH 05 MICRO INVERTERS INVERTER: (15)AP SYSTEMS DS3-L WITH A 200A MAIN BREAKER UTILITY COMPANY-PORTLAND GENERAL ELECTRIC UTILITY METER#38 195 142 EXISTING BI-DIRECTIONAL Project Name& UTILITY METER, M Address �_ L L . = _J L_ — J_ L� _I_ L� _I_ (N)BLADE TYPE 1-PHASE,3W, ow "./ /,-.../ N N (N)125A COMBINER PANEL, FUSIBLE AC DISCONNECT 120V/240V w T -t- T T T , 240V,3W,1-PHASE NEMA 3R 60A-2P 120/240VAC o LINE SIDE TAP -- — BRANCH 2-09 MODULES WITH 05 MICRO INVERTERS (VISIBLE,LOCKABLE,LABELED) USING IPC i w -, CC 60A FUSES 200A Eo-o a d o _ (N)JUNCTION BOX Et Z N ""'? 600 V,NEMA 4 20A (E) s < rn rn UL LISTED Q w ? -- L_ _J L_ m J L _J L_ _ _J • /V /../, ^�t /�/ /./ ` L1 L1 20A . Z Q —� J_ L 1 1 1 T Li IEIiT�S Et LOADt:n Q W W BRANCH 3-10 MODULES WITH 05 MICRO INVERTERS 20A o —p • Q U' Z L7 L1 L2 Z LLD P. O I ° O • Z 2 a u u N L2 L2 G I.. ;_.. Y G N >- L-----I G I > L —-_J L_ __ _J L J L_ _.-_J L_ — _J —T-- = —L— T - 1 II 0 CISheet Name EXISTING GROUNDING ELECTRODE SYSTEM 3-LINE DIAGRAM WIRE MAX PARALLEL C.0 PV CURR. TOTAL CONT. CURR WIRE TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE TAG# DEVICES RATING MULT CURR X 125% WIRE SIZE\TYPE\AMP. OCP #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) Sheet Size O 05 x 320 x N/A = 16.00A 20.O0A #10\THWN\40A @90°C 20A 2 TRUNK CABLE 0.96 x 1.00 x 40A 38.40A 16.DOA #6 AWG 20 0.28 ANSI B IN AIR 11" X 17" ' Sheet Number O05 x 3.20 x N/A = 16.00A 20.00A #101 THWN\40A @90°C 20A 6 3/4" EMT 0.96 x 0.80 x 40A 30.72A 16.00A #8 AWG 65 0 90 1 2 E 1.1 O15 x 3.20 x N/A = 48.00A 60.00A #6 1 THWN\65A @75°C 60A 2 3/4" EMT 0.94 x 1.00 x 65A 61.1 DA 48.00A #8 AWG 10 0.15 0 15 x 3.20 x N/A = 48.00A 60.00A #6 1 THWN\65A @75°C 60A 3 3/4" EMT 0.94 x 1.00 x 65A 61.10A 48.O0A #8 AWG 10 0.15 SITE NOTES: GROUNDING NOTES: , • 1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND J REGULATIONS. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH infinitysolar 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A USE. UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM INFINITY HOME SOLUTIONS 3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, NEC TABLE 250.122. 6405 E MILL PLAIN VANCOUVER WA 98661 OR BUILDING ROOF VENTS. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES PHONE:1-800-B18-0598 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). INFINITY so AR.COM ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC REVISIONS 5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN 690.45 AND MICROINVERTER MANUFACTURERS INSTRUCTIONS. Rev ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN ��wr Dale INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE BUILDING OR STRUCTURE. NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED - GROUNDING LUG HOLES PER THE MANUFACTURER'S INSTALLATION - EQUIPMENT LOCATIONS: REQUIREMENTS. 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT Signature with seal 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES ANOTHER MODULE. 310.15(B)(2)(A)AND 310.15(B)(3)(C). 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] ACCORDING TO NEC 690.34. 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 Project Name& 4. ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A w Address WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BE GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 U INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC AND AHJ. w APPLICABLE CODES. 9. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO o 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR REDUCE FIRE HAZARDS w USAGE WHEN APPROPRIATE. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: Oi- 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS g -I ' STRUCTURAL NOTES: OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE Q z N CO 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS). > Cr" z CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE 0 <0 O o J SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH z o -a BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAILS 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID UJ' rn CC¢ i' w MANUFACTURER'S INSTRUCTIONS. SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY < it, 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). z `D ~ a ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND REQUIREMENTS. 240. 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WI 5. MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED Q APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. FUSES IN ACCORDANCE WITH NEC 110.3(B). 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION > SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN ACCORDING TO NEC 690.11 AND UL1699B. POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED Sheet Name AMONGST THE ROOF FRAMING MEMBERS. INTERCONNECTION NOTES: NOTES 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12(B)] WIRING&CONDUIT NOTES: 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. EXCEED 120%OF BUSBAR RATING[NEC 705.12(D)(2)(3)]. Sheet Size CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT ANSI B REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL 11° X 17" 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED 3. VOLTAGE DROP LIMITED TO 1.5%. BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE Street Number 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING UTILITY SOURCE OCPD[NEC 705.12(B)(2)(3)]. SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL E 1.2 WIRING CLIPS. RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED PHASE B OR L2-RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- ACCORDING TO NEC 705.12(B)(2)(3)(C). BLUE, YELLOW, ORANGE", OR OTHER CONVENTION NEUTRAL-WHITE OR GREY 5. FEEDER TAP INTERCONECTION(LOADSIDE)ACCORDING TO NEC 705.12(B)(2)(1) IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH BE MARKED ORANGE[NEC 110.15]. SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(B)(5)]. WARN f ELECTRICAL SHOCK HAZARD I infinity solar 'MI /WARNING DUAL POWER SUPPLY TERMINALS ON BOTH LINE AND - i — POWER SOURCE OUTPUT SOURCES:UTILITY GRID AND PV INFINITY 6 05 EMILL PLAIN SOLUTIONS LOAD SIDES MAYBE ENERGIZED VANCOUVER WA 98661 ® w !0 NOT RELOCATE SOLAR ELECTRIC SYSTEM PHONE 1-800-e18-0598 IN THE OPEN POSITION w - RENT DEVICE. INFIMrvSOLAR.COM " LABEL LOCATION: LABEL LOCATION: \ LABEL LOCATION: PRODUCTION I NET METER(BI-DIRECTIONAL) WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE 1 MAIN SERVICE DISCONNECT NEC:2020 REVISIONS ENERGIZED IN THE OPEN POSITION,A WARNING SIGN SHALL BE NEC:2020,705.12(B)(3)(2) NEC 690.59,705.12(DX3) DescAplion Dale Rev MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. PER CODE(S):NEC 2020: NEC 706.15(C)(4)and NEC 690.13(B) \1 PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT 48,00 AMPS LABEL LOCATION: MAIN SERVICE DISCONNECT,NEC 2020,690.13(B) NOMINAL OPERATING VOLTAGE 240 VOLTS Signature with Seal I LABEL LOCATION: 2. /\WARNING AC SC OF INTERCONNECTION NEC:2020 THIS EQUIPMENT FED BY MULTIPLE SOURCES, '( _1A LBIMINI (PERDI CODE:NECONNECT,690.54)POINT TOTAL RATING OF ALL OVERCURRENT DEVICES,ll EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE," — — • y�y5k4,JD,N7T1.IP.Q,G11''OF BUSBAR,.tC Project Name& , �" "`"FT.,„�""s LABEL LOCATION: MAIN SERVICE PANEL,NEC 2020,690.13(B) Address LLI LABEL DISTRIBUTION PERMAN EQUIPMENT,AC DISCONNECTT WARNING LABELS SHALL BE PLIED TO A rATION: 0 CAUTION w NEC:2020 _ PER CODE:705.12(B)(3)(3) I POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE W ce FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS PHOTOVOLTAIC SHOWN. EL _1 LO DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES < — c-4 co J SOLAR PV SYSTEM a re Z AC DISCONNECT EQUIPPED WITH RAPID w Ci 0 o re LABEL LOCATION: SHUTDOWN - / ct Q, a W W AC DISCONNECT W Z H O �I NEC:2020 Z X k !HO ESOCLARC a_ Y PHOTOVOLTAIC SYSTEM SHUTDOWN PV i V SYSTEM AND PV PANELS -- - - z COMBINER PANEL REDUCE DO NOT ADD LOADS SHOCK HAZARD IN THE LABEL LOCATION AT INVERTER CODTE EARRAY005.11.3.1(1)&690.56(C)] - - Q Sheet Name UTILITY SERVICE ENTRANCE/METER,INVERTER/DC DISCONNECT WARNING IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS J _ LABELS REQUIRED BY LOCAL AHJ. PER CODE(S):NEC 2020.ARTICLE 690.56(C) ------ Sheet Size PV ARRAY 1- ANSI B in 11" X17" J/B ---- ---- -- -- — Sheet Number A rL _ SOLAR PHOTOVOLTAIC I C IAC O E 1 .3 — I AWA N I 28 PV MODULES 1 x , I I (PER CODE NEC 690) MAIN SERVICE PANEL PHOTOVOLTAIC —J H— _I AC COMBINER PANEL i \— POWER SOURCE L SOLAR PHOTOVOLTAIC AC DISCONNECT UTILITY METER - SYSTEMS LABEL LOCATION: EXPOSED RACEWAY,CABLE TRAYS,JUNCTION BOX (PER CODE:NEC 690) NEC:2020.PER CODE:NEC 690.31(D)(2) • Znshinesolar I OBB HALF CELL Back ZNSH I N E AR Eij ZXM7-5H108 Series tNSHINE MOnocrystatone PERC PV Module infinity Solar INFINITY HOME SOLUTIONS DIMENSIONS OF PV MODULE(mm) 6405 E MILL PLAIN VANCOUVER WA 98661 a PHONE:1-800-818-0598 1 @, a S H 1 I-V CURVES OF P,,,, ;JDULE(400W) INFINITY50LAR.COM @y earceee1 30±I a ann9191amvmr REVISIONS 1113 hilii{ii IIIIOf01lIJIIEWIIIl h1l lllr tl a I ew.,leoe-°eo4wm+ DasulPtlon Date Rev I''l IlfLiil IIiI111tlImiiR11 IINIIImmlmiln I i a..,."3 1 Z a LA Ili:3 N<` 1 OBB HALF-CELL Black Monocrystalline PERC PV Mod iil dlIIIIII mill�imm111111 p'wI Il�y�p�0��mIT ' e '�P -a..., t "�°"�°":: tit 1 1 t I�tlllitll�l111iIm�mllimm� immm • u!/ ` Cj a- hdnv,t N.e...roam', I FOP 1` �Ih1 �d l li 11 lfi1RIIIIllilpimlllii imlimlmmml .........�°W 1 ti� I t ' ItP 11 �tllllilltImm IIIMIMlimml 1nrnliltli�lllll6 � ,,I {11, ll IiliiB 111111IWii111111 111111liiII 1 Id I n ; ;o „ m n s Signature with Seal i'li'i I It;I.t 1 I$I 1 i I 13 f I 11 1 1 Voltage M +alli EMI o 0 11111P �j�pI�Imliillllltlii "� ,,:1 roil t Il �i 390-410W 20.97% 0.55/o fIl�ni mII�liilililumummun i P-V CURVES OF PV MODULE(400W) § fi I I tl 0019 . x° V0 1 I T . POWER RANGE MAXIMUM EFFICIENCY YEARLY DEGRADATION limili�lllllllliilllll:lll@liiiliill1lli1111. -i„m1,..251 �,„m. h�l tl u { i` 1111im111liIIHM1I111111111'ml11mmimm Ail,t^ 1 1a �•60111/1/41,0 fe1411 lj !+. Ili - _Irc.IbM enK190.'UwVnI tilt 1 a I I, imlill inim��mlftlmilflimlllml�lmm _._, _I, ...„.�w,m' hNI t ilia 111it L 111111111 lmi11111W'HEIH ml� 11111 °„ ""'° °r^°°°a -- t,;I f x Project Name& fdi11� l 1, 1i IN ? 12 12 YEARS PROt IJ RRANTY 25 25 YEARS OUTPUT GUARANTEE mmi1111iiI11I111IIidlmlllilmmlll�llmlf y Address L' k 1, 11 ill d MP!it El, IIIME111111l111im1111 II111Ii11111m1i'��1lli. b I 1191.-22 U ,ao z / /� Front View Back View ._-- W as [ C PVCY LE \ -Oemarkrdsrom.o:raneo ro,rs ca., rynaretubteuv_.ortue'I a a x m on 40 enaarn c. c �s \ .! Voltage M LLl _alnadra IY 6 EC611 6t:{0!IEC6tr0171E62116:s 5 .rill-IIUL6o 730- O i50'4f1 t t.onmnldl Mand m m --I 'CrtO gePnt_ ste N U c su'k ELECTRICAL CHARACTERISTICS i 5TC' MECHANICAL DATA Q Z_ N rD �504n01 Our IIManagementSyrst'm > a) Q Cl, 80% Nominal Power Watt Pmax(W'p 39C 395 400 405 410 Solar cells Mono PERC Q N Z E 50i5'I) 0 root Of It H 1 5afetyM y enL Sy.tem �/ Q 0 �� 1 15 25 0 O J Years ,. -... .,.,.,. . Maximum Power Voltage Vmp(V) 30.50 30.70 30.90 31.10 31.30 Cells orientation 108(6r18) - .~_.Q Z ce Maximum Power Current Imp(A) 12.79 12.97 12.95 13.03 13.10 Module dimension 1724x1134x30 mot(With Frame) Q 0) < W W Open Circuit Voltage Voc(V) 36.70 36.90 37.10 37.30 37.50 Weight 20.511.0 kg Z � ~ d KEY FEATURES Short Circuit Current I ar(A) 13.56 13.6f 13.70 13.77 13.84 Glass 32mm,High Transmission,AR Coated Tempered Glass g Excellent Cells Efficiency -• Better Weak Illumination Response Module Efielen Cv(%) 19.95 zo 20 zo 46 2072 zo 97junction box IP68, 3diodes MBB technology reduce the distance between busbars and More power output in weak light condition,such as haze, r '' Cables 4 rim',350 mm(With Connectors) > finger grid line which is benefit to power increase. cloudy,and early morning. Connectors' MC4-compatibte Sheet Name PV MODULE ELECTRICAL CHARACTERiSTICS I NMOT TEMPERATURE RATINGS' WORKING CONDITIONS ' Anti PID f,- Adapt To Harsh Outdoor Environment SPECIFICATION 1 1 Maximum Adapt Pmax(Wp) 291.50 295.20 299.00 302,70 306.30 NMOT 44°C z2°C Maximum system voltage 1500 V DC SHEET Ensured PID resistance through the quality control of cell �/ Resistant to harsh environments such as salt.ammonia, manufacturing process and raw materials. sand,high temperature and high humidity environment. MaximumPossel VoltageVmpp(V) 28.30 28.50 28.70 28.90 29.10 Temperature coefficient ofPmax -0.35%(°C Operating temperature -40°C-+85°C Sheet Size Maximum Power Current impp(A) 10.29 10.35 10.41 10.47 10.53 Temperature coefficient of Vac -0.29%/°C Maximum series fuse 25 A ANSI B r-f- JJ L TIER 1 Qw Excellent Quality Managerment System open circuit VoltageVoc(V) 34.30 34.50 34.70 34.80 35.00 Temperature coefficient ofisc 0.05%NC Front Side MannwelRtateloading Up to5400Pa 11u X 17" �� �� �� Global,Tier 1 bankable brand,with independently certified Warranted reliability and stringent quality assurances well Rear Side Maximum State Loading Upto2400Pa Sheet Number Short Circuit Current lsc(A) 10.95 1101 1106 11.12 11-18 -. advanced automated manufacturing. beyond certified requirements. x "" ' vrt.r!,r.:rr,,r Sr.E°WJIr';Or tre 1 T,I, .trr c... ....050Yed m.:. 'm.M"IE Ca f03 550w3 N41'°"b Y1-1 E 900001 0,00 002011r000'. �� �� Te,u,y-92(VJxn.YW1 mu92419r r rcul e-yr •GL.„ 1Yb l0-.d. d,t i k.-"M N I 'arm: lei -I 2S 1 b.r'Iaaa rrrrr2 ,.ri 5 PACKAGING CONFIGURATION` ,�;a an- :r= ham xu�xv, �:>u I•.1 �.� ,1 Improved Aesthetics Pierer Hos 36 Compared to conventional modules,this full black modules Piecei Container(40'H0) 936 have a more uniform appearance and superior aesthetics. ..as.,r,>«�wsara.latie ce,.n,e Founded in 1988,ZNShine solar 15 a wOr{d'.,Ieadirel high-tech PV module manufacturerlVith tie advanced precuction tines the company b0a515 rnoduie f9 Add:1N,Zhixi Industrial Zone,lintanpangsu 213251, P.R.China ' Tel: +86 519 5822 0233 E-mail'. info@znshinesotaccom ca,:a uy c3 EGL7 Bloornbery h,ls Listed ZN Noe as a gloffal 1:or 1 CV module maker-Today Znshine has dtstribulee rtS s3t9s t-more than 60 countries around the globe. Note:Specifications included in this datasheet are subject to change without notice.ZNSHINE reserves the right of final interpretation 2 ZNSHINE SOLAR 2022 I Version:ZXM7-5H103 2202.E w'ww.zrishlnesoldr.CO No special undertaking or warranty for the suitability of special purpose a'being installed in extraordinary surroundings is granted unless as otherwise soecitically committed by manufacturer in contract document '" A 1 APsystems t }}.1,., dI Datasheet DS3 Microinverter Series infinity solar Leaeling ll l� Init us try in INFINITY HOME SOLUTIONS * ALTENERGY POWER Solar Microinverter Technology 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE 1-800-818-0598 Model DS3-, EiiS3-L DS3 INFINITYSOLAR.COM Input Data (DC) REVISIONS Recommended PV Module Power(STC)Range - 250Wp-480Wp+ 265Wp-570Wp+ 00Wp-660Wp+ DS3 SeriesTracking Voltageop�an Date Rev Peak Power 22V-48V 25V-55V 32V-55V Operating Voltage Range 16V-60V 16V-60V 26V-60V .,... The myost�Cro�nve�,�er powerful Dual Maximum Input Voltage 60V z 9T l'/ Maximum Input Current 16A x 2 18A x 2 20A x 2 fl .. . '_a r Signature with Seal 2 21 - One mlcroinverter connects to two solar modules- Output Data (AC) } ( • Max output power reaching 640VA,268VA' or B6OV.A Maximum Continuous Output Power 640VA 768VA 880VA il • Tvaa independent input channels(MPPT) Nominal Output Voltage/Range''' 240V/211V-264V CA Rule 21 CUL1741 SA)compliant Nominal Output Current 2.66A 3 20A 3.7A • NEC 2020 690.12 Rapid Shutdown Com Plia;tt Nominal Output Frequency/Range"' 60Hz/S9.3Hz-60.5Hz • Encrypted Wireless ZigBee Communication Project Name& ? Power Factor(Detault/Adjustable) 0.99/0.7 leading...0.7 lagging Address Phase Mot^:itorect and Phase Balanced Maximum Units per 20A and 30A ncO% 6/9 5/7 4/6 W AC Bus Cable 12AWG/10AWG Z W 0 Ettnnnacy co Peak Efficiency 97% CC CEC Efficiency 96.5% d d g- Nominal MPPT Efficiency99.5% Z N Lo { { FEATURES Night Power Consumption 20mW Q ti CD �' ce N Z APsystems 3'e generation of dual microinverters are reaching unprecedented power outputs of 640VA or 768VA or 880VA to adapt to today's M Q o alarger power module. With 2 independent MPPT, encrypted ZigBee signals, the DS3-S, DS3-L and DS3 benefit from an entirely new MCct1;3n{ca) Data 0 O O o architecture and are fully backwards compatible with the QS1 and YC600 microinverters. Operating Ambient Temperature Range -40°F to+149°F(-40°Cto+65°C) LZ co Ce r. M Storage Temperature Range -40'F to+185°F(-40°C to+85°C) IY rn CD Z W The innovative and compact design make the product lighter while maximizing power production.The components are encapsulated with z tin O silicone to reduce stress on the electronics,facilitate thermal dissipation,enhance waterproof properties,and ensure maximum reliability of the Dimensions(W x H x D) 10.3"x 8.6"x 1.6"(262mm X 218mm X41.2mm) co = system via rigorous testing methods including accelerated life testing. A 24/7 energy access through Apps or web based portal facilitate Weight 5.71bs(2.6kg) Z id remote diagnosis and maintenance. DC Connector Type Staubli MC4 PV-ADBP4-52&ADSP4-52 Y The DS3 series is interactive with power grids through a feature referred to as RPC(Reactive Power Control)to better manage photovoltaic power Cooling Natural Convection-No Fans } spikes in the grid. With a performance and an efficiency of 97%, a unique integration with 20% less components,APsystems DS3-5, DS3-1_ Enclosure Environmental Rating NEMA 6 and 053 are a game changer to residential and commercial PV. 5 F eatiares Communication(Inverter To ECU)n Encrypted ZigBee MetN me ICRO WIRING SCHEMATIC Isolation Design high Frequency Transformers,Galvanically Isolated SPECIFICATION Energy Management Energy Management Analysis(EMA)system SHEET Warranty^' 10 Years Standard;25 Years Optional Sheet Size Eiiiiii �■■■■■■ ■■■■■ ia.M.MIE 111111111 MMM■■■■E MMMMMMMM M■M■M■a uua■M■M Compliance ANSI B ■■u■■m ■■■■■■� ■ ■■■ ■■■■■■� M�MH Safetyand EMC Compliance■■1g11M EM■IN1NM 11� 1111 M11iIN1INE 11■p■■■■ 1 p ante UL1741;CSA C22.2 No.107.1-16;CA Rule 21(UL 1741 SA);FCC n ■■■■■■■M ■■■■■■■M Ea■IN1■1M aauu■11E 1,MM11EE11 _ ' Part15;ANSI C63.4;ICES-003;IEEE1547;NEC2014&NEC2017 Section 11n X 17 ■■■■■■■M ■■■■■■INM ■■M11MMM MEIN■MINE M1M1 INM■ 690.11 DC Arc Fault circuit;Protection NEC2014&NECZ017 Section I E■■■■■■M M■Ma■■■M M■■ MMM MIMMINMuu E■■■■M it Sheet Number ■■MM1■MM ■MIN■IN11M 11111111111111111 EM1M■M■ 11•1111111.11111 690.12 Rapid Shutdown of PV systems on Buildings;NEC 2020 1MIN11MME 1111111111E MEMM■11M M1111111E I111111111111111111 DS 02 MMMM_MIN�w •.AEM11M E111.... •-.•MM■E M1111111m i Nominal voltage/frequencyra ecan be extended beyond nominal required the utilit ©All Rights Reserved �.�� �!i MV 1M■ ■■� Oye range yH q y. �� ��� 2�Limris may vary Refer to local requirements to define the number ojmicrpinverters per branch Specifications subject to change without noace please ensure you are using the ii II ji iI ii In your area. most recent updotefound et web.usa fiatems.[ym I" -'"' (' - --'1 — — �' } C Recommend no more than 80 inverters register to one ECU for stable communication. -"' I j -- lj— (� sa.APsTo be eligible the warranty.APsystems microinverters need to be monitored r "^V ! /s via the EMS portal.Please refer to our warranty T&Cs available on uvsfems.cam. c. y.� I I v i APsystems / Meets the standard requirements 600 Erickson Ave NE,Suite 200 Seattle,WA 98110 SpP® for Distributed Energy Resources Tel-844-666-7035 tut 1741)and identified with the C CA listed Mark ' apsystem,.com \ / 2022/02/15 Rev1.3 0 Er IT, infinity solar INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 Powering Business Worldwide pe.eaton.com PHONE: SOLAR.C5M8 9 INFINITY 50LAR.COM REVISIONS Desaplion Dale Rev BR style 1-inch loadcenter Signature with Seal BR816L125RP UPC:786676001472 Dimensions: Project Name 8 • Height: 13 IN Address w • Length: 3.56 IN z • Width: 11 IN w _ Warranties: L w • 10 year re Specifications: Z N LO • Special Features: Current design > " • Type: Main lug < ¢ csJ z • Amperage Rating: 125A o o o • Box Size: 7r w V • Bus Material: Aluminum z zz w • Cover: Cover included z a • Enclosure: NEMA 3R _ • Enclosure Material: Metallic • Interrupt Rating: 10 kAIC • Main Circuit Breaker: BR • Number Of Circuits: 16 • Number Of Spaces: 8 Sheet Name • Number Of Wires: Three-wire COMBINER PANEL CERTIFICATION • Phase: Single-phase • Voltage Rating: 120/240V Sheet Size • Wire Size: #14-1 AWG Cu/AI ANSI B Supporting documents: 11" X 17" • Eatons Volume 1-Residential and Light Sheet Number Commercial • Cutler-Hammer Type CH and BR Loadcenters - DS 03 Instructions • Type BR Arc Fault Circuit Breakers and Loadcenters • Eaton Specification Sheet- BR816L125RP 0 Switching Devices 11 1 Switching Devices infinity solar Safety Swatdles • 1 • Safety CSpitches INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOIIVER WA 98661 1 PHONE:1-800818-0598 INFINITY SOLAR.COM Product Overview =pin ProductDescriptian Milder&and Certifications Product Selection Guide • Used to open or close • {1t.a`03 REVISIONS i a crceurt • tf L 50 Description Date Rev Safety Switch • Non-fualble safety • ly EMA XS1 switdhas provide a means +. i to manually connect or 1 disconnect the load from C k ,...'Ai the SOUPCa s 7 • fusible safety switches provide a paeans to Signature with Seal I manually open and close ,ita circuit and over-current Cprotection by means of mstaIled fuses - 1 r. • Also commonly referred oeaenMme eeneferedy xn�o* ru-file Mara le W-Tr rr Eutaw Mary swIrs to as a dsconnect Mitch a Ssconnect Project Name& NP• srplenewtm -., strga.8eor semen noitEtrurm MO ni AkaemnGIWi loorrom zotic • Available from 30 to 1213UA Address a411Vzhmase -r IXiAl M r;tac 400 horaapawrr rated tb halspu•v rani W PitA0 Tie 0 hum i tamp corrA c-fi =rev ._- Z W CI r. 7: L�LJ te Jo, at-me At 1737 _. d 30.t.4 L; 3E-TA ?a-17X iG.i?, § a o J sit tf! es ZNQ Ncr-totw T arta3 7 L4 sal 6 6 1,7,4 8'Yt6 Sand 4 a C cc O ce O ... r 1.106.9i1F h Z 0 v Noel', W co ct '. fiat* -- Yes as Q (.9Z W *Mobs tas — 'Ms wo Z 2 1-- 0 NE\tA,aR z = d Fttr7f3 l+et was — 'R5 Yhs NIA4A I? r rile _.. Yes.'1p b 7(Y-14 A Yet Ves Q !ti4it.hs — .. S ti, YA3.upOG fp1A 'not NEW t meted I Faeaae .. -- _.. _. Sheet Name NEMA AN stateess ahem AC DISCONNECT Fable -- - Y'?L,op to was Yes NM -- ;,c1 Yet vas.upa;Jou , , ULCERTIFICATION NETW 0 oshatehrt. Naga --- IkitMak — — Vac Sheet Size NEAWb9 ANSI B upPiIOU — ._ 11" X 17" aon.rota -._ vat,up at t074 Ii -- — — NM Sheet Number See Nleent c to.nomaor iray?4x rAe ov1:Jai ..1 thaed mar!sells ea mtthismeeaf NEMA Nye 12 erekriiItn ix:,0EI ran x Feld nxnhL,:a meet NEW Ai ra seroat w emenis Wail a tarry method gad screw Is reason .y,Cl krye DS 04 Valuate 2—Comm ante!Olstreartbn :18t..r810601113E—a44A2014 rv.oatanon V2-T9-2 V2-T1-4 Vorme 2—Cammerdat Distribution :A0..8i,:b501E-Apn12p1E warraemncom 1 I Switching Devices 11 safetySwtdes 4 infinitysolcr INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 Cross-Ref OfenCB I INFINITY SOLAR.COM Genera!-Duty Geseer41-D Lay. t.G4nnnt4 REVISIONS As�e tutu tog NOmaer AIMpe a Cseaieq Milmtwr Deaalptlon Date Rev einem Eaton General Electra Slemete tien0 listM €aim General Flect&c SIB Semen 8 `Plug Fest.save-ecee.r fo-WY9.in wee.fEMA 1 F16de.Two-Pole,T i e-wee,246 Vac,NEM 813 9C OP111NGB IPF13O tf111N - 86221111113 T11;11 UMW W D221N18 - Plug Feae,1Yro-PM0.TAlue-wore.241'WC NEM A I 6627031118 T;^,3222i UMW W17Wi8 sc OP321NGO 118220 1.f211N ffi31N 062231118 TG3tI31 1PMel4 WWII Signature Oh Seal Feemlr,T im- e4e.Tiber-WNW NO'1he.FEW I .3'J 0622411191t TG32219 I2if 241W 8714W6 311 BG22111188 talV1 GMIN 0721N 40 INS TG 2!1I Fa-22S61 19915081 60 0622 T63T22 2222e 8222N 689 D622e111 TG922611 G17212t1 11236W1 'DO 1962234066 1ET3223 Gf797.1 I38 F10611.Thlee-eote,TBree-wle.240 VNc.WPM IR 2110 D42242168 112P21 Ornn4M 100241 O 08321111118 TG43219 t23Z11111 032-1188 460 D62251161E 163725 14-325M cum M 06322NR8 TG4122r1 18227101 IT 2218N Project Name& Ere 13C2141GN Tr./225 GFZNN 1173101 1!re 0675911O18 TC.44/71 Ir:1231Rt =MAIM W Address F1na114e,Thee-Pate,T121e412R4e;2i8 Uit,HEM I 210 06224181K 13132419 1i994111 1/324.Wei U 1 1961211198 TE.8Zl :9- 5 Ir?4 ate 04;325FILI T 917.9 GF37.14,1 91756111 W CD 66 061221168 194.377 MO 962261111E T Q..91 1F3761001 117061.19 XL D62214KB TG42'1 =."f,!Sti ..'.»"3N FBaNee.Thee-pule,FarR1MMe.2481raC',1616A 8R W CL MC 063241193 114224 l322414 17374N :41 063121111118 111431219 7121NP Rili WM 411 1368251FGC TWOS Gf77'h U32GN 6O 062II1R5. TG431e1 iitam 03221414 d d g- G324FGK 1GI19 :i's Mgr 0321N '.23 0 MI1 62738. ,7T2 4. 3 3215R 1 GF UMW Z N co EiT O crt Fus101e,Three-Pole,Four-Wm 240 Vac,MINA 1 293 DURUM TGKM4H ri724,0 U324N111 > N Q T 06321N68 11:44' ii3716 U371?! 4a0 86448 3%"a3-11t TG1 Gf37.019 3229111 Cc CCZ e €3 063222168 TG4Te2 GTT22N 0.2'77!N *11C. 86112611111( Ta3 f£i' Gf126N1 0376 Li CI 0 O Is- — Z CI lT 061211158 164371 11T2N D3:`3N Non-Feelble,iwo-more,1Wo-YWhe,240 Ya[.FEM4 aR W co Ce '. M ft act( Li :7- oCaa4N6K T6114 3324N O'32444 AlOG2211246 125221? 152 22,9 3122190 Q () Z LlJ 00 D6325I= TUTS 3?15N tm7At ill 0622211213 9,N2229 9437719 3132i11 Z 11,CO ~ 2 CT D6226N18( 164-86 G 326,8 OTAN ''Tr 6624319188 352271 G4r1;71 CQ9TNP& Z ' d NDI4FOSNNe,two-me.M --WBe.240 Vac,FEMA 1 .111 D632OMK 2421249 6S0724F1 7152I1 5 30 06221U68 1683321 N/A WA Non-Enable.three-eve,Three-Wte.240 Sac,2,EMA 3R Y E3 06222U68 16N3322 NA 000GGN5T5 :al DG121UKB 72d',''3 , .. ."''T1 IT 06221t168 18242221 N/A 002TC4NS GO DG322URB hi"J: .. 5 73C D62241141 1E143324 N/A 911324 '.D3 PG9GOI it 1GN237 411i-2,' :;L 1110 4A 062254811 162432'6 N/A UL826 293 DG2IWRK T:TN224A Glfi2t:-.. .1224.FE Sheet Name IX 043l 11N326 Nat 01725 483 06745IIRK NA N/A IVA. AC DISCONNECT Non-FuscN,380234044,Twee-wire.240 vac.MEMA 1 GA1 DG32641RIC NP. N/A 'i UL CERTIFICATION 31 136321U68 1514332 5 e321 3iAe1 AIM 69 D6322JG8 11i43222 Gr*322 131A72 :.wate-euta rt srecited. Sheet Size I T OGITJUGE1 11142201 GJff371 DL073 Always teret/to r411.Cx G4 peas a a 41113"acute:Wm.:Mace Nmateet ray 3.14 err r 2% 0632cJ6K 1G11an4 sr* 017324 nu"dat40i ANSI B 41 063641611 16113325 GAM 01132 11 rr X 17" iff.. 06326116K Imam WI" OWN Sheet Number DS 05 V plume 2-Commgclal D Ntrlb4Rton -CAO8Io0063E-2t.:7.a2b raHvcamn.mm V2-114 V infinitysolar RSTC Enterprises, Inc. INFINRY HOME SOLUTIONS 2214 Heimstead Road r. 6405 E MILL PLAIN Eau I Claire, q ©. SOLADECK VANCOUVER WA 98661 W t I "'f INFFIINITY SOLAR.COMB 715-830-9997 .1 FLASHED PV ROOF-MOUNT REVISIONS COMBINER/ENCLOSURES Deception o� Rev Outdoor Photovoltaic Enclosures 0799 Series Composition/Cedar Roof System Signature with Seal ETL listed and labeled Report ft 3171411 PRT-002 Revised May,2018 _ • UL50 Type 3R, 11 Edition Electrical equipment enclosures _ Project Name& • CSA C22.2 No_ 290 Nerna Type 3R . Address • Conforms to UL 1741 Standard : W U Z Lir p 0798 Series Includes: NW cc 0799-2 Wire Size 2/0-14 v 0799-5 Wire size 14-5 -A-0799-D Wire size 14-8 Z N Models available in Grey,}lack or Stainless Steel p p O o Li Z O �§ ix Q v 0U' z Li, Basic Specifications z O z a Material options_ 4 t' " • Powder coated, 18 gauge galvanized 90 steel } (1,100 hours salt spray) • Stairlcs steel Process-Seamless draw(stamped) Flashing - 15.25"x 17.25" Sheet Name Height-3" JUNCTION BOX UL Cavity-255 Cubic inches _ CERTIFICATION Sheet Size Base Plate: ANSI B • Fastened to base using toggle fastening system 11" X 17" • 5 roof deck knockouts • Knockout sizes: (3)_5",(1)_75'and (1) 1" k � Sheet Number • 8",35mm slotted din rail DS 06 • Ground Block Passthrough and combiner kits are available for either s�oena, ue AC or DC applications. Cris-Linked Polyethylene Insulated LI 1 ', 2kV Rated PV ie-750MCM• V •-40°Cto�°C Wet and y infinity solo � INFINITY HOME SOLUTIONS 6405 E MILL PLAIN Description VANCOUVER WA96661 oarnran0ovoac cable hash e a cfarnca1 PHONE:1$00-61 ADCs S ( hk brand Pht tt � INFINITY SOLAR.COMCOM cross-linked polyethylene insulation. Bare Copper Applications REVISIONS Rev Appropriate for use in attl9r power appiiciatioins that niquire UI2,000 volt rating. For use in grounded interconnection and COmu/ ungrounded Photovoltaic power systems_ C Construction 1 CondaxorR Str nded ban)copper conductor per ASTM B-3,B-8_ Signature with Seal INSIP /t ♦ XLPE Insulation Avaiaide in7or19 stranded v naortaswen m Wiriedccpper. Insulation; Chemically Cross- 1ked polyethylene I ',l , Colors: Black,Green,Mite,Rod Print on one side with a 1 ,.:,•••a ' contrasting ink. An extruded stripe and other colors are avail- able upon request_ Pro NaAddrme & r. UJ ma "" tis industry Listings Standards Z LA_Listed asPhotovoltaic per Standard S1fiject 4 i 03 and as LU try w IM+Ir Cable identification -40° °C Dry Rated 0 {y� % "ADVANCED©KifTl41 CABLE INC.. lOt AWt3 Gasoline and Oil t II LU EC rim PV WIRE OR JBIW-2 2001W OR USE-2 60W io`C Rol-IS Compliant �l�+1�,) p� WET OR DRY(-400)SR WillDBiECT BURIAL RoHS Sunlight Resistant iiiii-IQ O_ d c 0 E32-s�1• ^ld 1 Flame Ra"ng Optional LIVED z N CO CD CY aIns ela.inr Trice ?.l.molter 6.6_ Approximateo o Part Number AWG «,_.,� reas Net Weight Z D Q n,ii.; (ncri) ball NV LU rn Q Ili w /r'r Tr Lim 3182PPV 18 7 76 .196 18 Z H o 3162PPV 16 7 76 238 22 d 3142PPV 14 7 76 221 28 3122PPV 12 7 76 242 38 Y 31012PPV 10 7 76 .284 61 Q 3082NPV 8 7 BE .314 78 3062PPV 6 7 86 .361 112 30426PV 4 7 86 .399 168 Sheet Name 3032PPV 3 7 86 .427 203 WIRING 3022NPV 2 7 85 .459 249 SPECIFICATION 3012FP �V 1 19 105 .6 321 30102NPV 1/0 19 105 .672 390 Sheet Size 30202IPV 2/0 19 106 .616 480 30302NPV 310 19 106 .667 s90 ANSI B 30402NPV am 1s 105 .722 737 11" X 17" 302602PPV 260 6.1051 37 120 _798 879 Sheet Number 30300214PV 30061CM't 37 120 .846 1046 -II 303932WV 36061C,M 37 120 .901 1198 DS 07 3094 ( 40058314 37 120 _946 1366 i 3061302NPV 600MLY.t 37 120 1.029 1673 lel 11 litille 306002?4 600MGId 61 135 1.136 2011 3+} 502PIPV 750 MCA4 61 136 1238 2618 11e blur sin coddled anirk apedidcm Is Intended hr be used es a pee i undid amebae and is Wined la be'Matte. AibC Ice aline every OW train the date*loom stew kmask al the tine an pitekabze.Tts ape.±lLitt°.Is adled ba dodge nice NE1961S 1[6:11 PHONE: (800) 343 2579 • FAX: (828) 389 3922 e WWW.ADCABLE.COM C infinitysolar Grace Solar (;rage Solar Fl M]vNT:rtG$'o i *AO Grave Solar Brace Solar r.'L atd+'.Mr`,srS?CM INFINITY HOME SOLUTIONS 6405E MILL PLAIN .. '..q- VANCOUVER WA 98661 SOLAR Components PHONE' l I.OM8 ROOF M0UNTIN SYSTEM REVISIONS �(��1� Karl sx+rr a Li` __ ; DesalPlion Dale Rev ED 'icc k h :+1 G5 Fki.0 Y" �.� i�-I RaE Pitched Roof Mounting System{ Flashing L feet} n* on-zinc ► ` ► 111111011i" , ,` _ Alain material Signature with Seal -_..s.•...= � '; Anodized Rt&a05-T5 ---m-- � *Benefits ,.. :111 1111 ' •:., •Waterproof funotion -, ,;., .�„�- 'iiw� '�` +Easy1nstaliatioc � l'r��iN` Tha canoeing he prereaste vblyed in the Snell II•11111*a>11 Project Name& raclaq 5e save yaur gaoler leg on 5me 4'n ;Lan e �t 1 lilt t� Address u s sea. ir arsrs� W __ .Flextourty and Gompatmnrty aliases z -_ Can eo Ina?a6lad wlLn matt ht stjlar panels a,°-,9... .��..k --i _ underor in the Mrferent tend man, •• .�I�� 1�� ��i� ... =* •standard mifiwi tle,11ifiia w ISt790i11:30Ut'i,ltk P,SaNZ3 I1 t�3and Et earn.lntersetpaaal atrt c:Lao load ". .-w t � _ . {+, i,., sv c, m �¢",• ; o e x,., _ standards. a d 0 Z N N > _ iT Fs] Z Inl a?SGlrla &l. ® d.„61i1t[,;1C- fed r•, d_L; _ 4C,rper 4/are ®ui .�$ • ¢c `•�y.' Q O J ' c W % ` .• c 0, < ww 0 Z _ .:. ter r ' Z f0 ZO I �y Y �.i a- 1 2 Sit t Rail Rail splice kit Wave piece Clamp kit CIS-DR.21C0 t"sS (IR..SP c",S-S';,:C r11 >5-ik-L:,- d- ` GS-Flit-01:02 Sheet Name boon*tcia W v lema Hoak MOUNTING- A4raaSCrle 4 R'f eo a4!rut*}.jYB�: Shingle Roof(L Feet) 1 'r ar MsmR' DATA SHEET- , 4. _,, _,,,p. _a aems°.. Sheet Size 5 s 7 s ANSI B Inter clamp kit D-mod ule End clamp kit Ground clap 11" X 17e GS-ic-P GS-A-DM CS-EC-r s".,S-G-Gfi _ .-' " - GS-IlK LD05 Sheet Number .Desdalp9en.('r51.Met 'y' �y;*n --- __'— A:ceil v4ee Anna t�c.nwd Sage Dc OQ 1 a la i f - nS-A-ARot Ground lug Bonding jumper Flashing hook oa":"°`gym A"`-R„lra"``° (S-G•GL GS-G•8.1-A GS-S KA° Tin Roof(L Feet) 1. V Oriiiiii Grace Solar Gras. AY RV44:140'r 3SY5TE1I4 infinity solar INFINITY HOME SOLUTIONS 6405 E MILL PLAIN MAIN PARTS VANCOUVER WA 98661 GS PITCHED ROOF RACKING SYSTEM INFINITY i SOLAR.-0598 NFINITY OLAR.COM 11111333311 REVISIONS Drrrodr/e be put into GOO Rail from any posi6at via sisimpleQtstallatiknt. Deexipfim Dale Rev Benefits *Pre-assembled for easy Installation D-ri lute can be put Into GD Rair from any position.This makes instellation smiler and can save you time on site. t ✓ d '• Signature with Seal *Various Solution for the different conditions y ' GD Rey and its accessories Can be installed with Me most solar - 4 t panels on the cc rr Trial and residential Roof. � �, f , *Safety and Reliability " Project Name& fir.. Address The racking systems designed by skilled engineers can stand up to the extreme ,1'' U weather cornptying wait the ASTJZS 1170 and other u1t€'rrational structure toad w stendards.The main support components have also been tested to guarantee its o structure and load-carrying capacity. GS-DR-Length(Classical) GS-tOR-Length(Economy) tu Description: GS Rail 1# -Description: GS 1D#Rail Technical Information s x2Smm Spec 46x2&ren v a o N Insia&atior Site Commercial and Residential Roof Q' C rn c- Tat Angle Rushed with the roof up to 5Ddeg Material Aluminum&Stainless steel p 0 O o Building Hto 2Om Color Naha-aall&Black i _ tJal:�e�.t"t be-na�r�tc�J into W co CC ng Height up the va Pa d' Q Lll W Max Wind Speed up to OOn ms Anti-corrosive Anodized ?'„ '',pi- -,. ti;a ,,.. 1. Z "1 crj H O t` tO z Snow Load 1.404/m2 Warranty 10 years warranty 'WI'."`" `"' ""'�" d Standards ASMIZS 11768 DIN 1t><55 DurationMore than 20 years s ., Y >- GS-DR5-Length Mount with the cable GS-CRC-Length > Description: CS SA Rail Description: Rail Cep I .0 � earn- ', , " Sue : x4fmm Sc 24x 10rraca Sheet Name ..,., v .NRv .s RACKING Ye DATA SHEET Rath Connection ' Grcundirg;;ashen Washer Sheet Size ' ANSI B �' le - 11" X 17° • • ate -- r F J Sheet Number DS 09 , ,- -- _-- — _ GS-DR-SP Rail Connection GS-DR-SP-GW ., 'De5CT1pti(Nk: Rail Spice 'De5{XlptlOn: Rail Spice with -Spec:: 150rnm grounding washer!washer Spec: 150rr1m a xllmon Unica SAr Tachetassy Ca.,LW. xiaman Grits Rau Te¢eneaoay Ca.,LIC. www_9reaelaYr.CYl4 P w.rreeeeSrer.acm 0 1 Fr .,- ..,^'�}G`, - ",^xys { , ,,g, x `a4mz? v.. n�- ,, y n„„ , ':5"g,`, `" -,;t ,. °"` , a r-,9, yes @,p.:%,t a s?i 'i ? infinity solar w °,7.`, r v F v�$a { :', e z s E= a a 'i ¢ • 9 c r 'i £ �Fi: z s e d°.,' t �. ,,... ----`' �.,4.,. .z, .;:? is +rr ..., ��,g�,��-� _ 4a � �03`fit i ��" 4,� ra �.'� �-" �x.:s j >'yt� �i =4"�^ • ., 4• yc .�r�k `t .^ N.:.�, "-�':. INFINITY HOME SOLUTIONS [jam•! p^� (+� £ "zC b3? T` +Y 1 f r3 'ap Y r3 {,b•asYf� �: srn "a, ° s'.';mw'y3t�'z` ya_ {��i .p. ir • ;^ r g'k"4, ' c t z T " z /asoi 640.5EMILL PLAIN VANCzs,rxrs'r.�,.�ov ;*i.. Y `"v o "�' x4' e • b'x r,,y-C ' Wa _ `,,,,' 98661 '?`+ 7�"x�°Af' :<.x'§�� ywt'. 'at ter; v ..' �, °� ° k- 'r [ " . . :9 ri .: :? .'T2a:. ?a .,r..Y . _... , 'r •a_ '::ix'a..: �• -rry Murrs::+rwr, PHONE 01-800.8UVER 18-0598 INFINITY SOLAR.COM COMPONENTS REVISIONS DesaVlon Date Re .,� -4-Fo s-i'- „ M4 ., "..�. �"-> -k > ' `•+. mr Signature with Seal ,'" C '.•-'s9. '1 '. - ,- Features r ti'M� - ' " " • Material:SUS3O4 ,,1�q ' - •. - - Nbr'a�kw> mmwvr ary lilt racmanm*""'"�'" " Special rib both surface to pierce the aluminum anodizatirm it i -'!,�,,_t • Co rated with Inter Clamp to install under the Fail Project Name 8 *II% ` T Item No. SCE7 tfOf! Adders 'i * ' '" G Grounding Clip U ram':t i L. "_# +�" °,,, ,.f x eir er.se+�e�Wance Esw; W ,` &e `.ir. w.+Ke � „. .. to Lit— a s s Q Z CV CI fD .. __ Fr,,"rtion iron > ICJ; CD Q • Connect system to equipment ground conductor Q Z SOLAR ARRAY o C O High Pre-assembly W 0 _i G .'" OLTNDIN SYSTEM Ream.. Cr (3m W GS-G-Gt_ Grounding Lug Z CO ~ a . Introduce •Material:F116005-T5 lay-in lug&Stainless Steel clip&A2-70 bolt GS Grounding Product can be used to bond solar modules to the aluminum rails and the Y ate, } aluminum rails to ground, so that the entire solar system is grounded and safe; Grounding products Q incuide the stainless steel grounding clip and aluminum grounding lug. which are all designed to comply OS-G-CGL Capper Grounding Lug 5 with the requirement of AS5033,UL467 for bonding or grounding systems. •Material. Copper lay-in lug&Stainless Steel Clip&A2-70 bolt Sheet Name <; Planning Layout RACKING- * . � �,-. GROUNDING t cppor'`W•rs Sheet Size 0 Grcuraring Crsr Feati trei ANSI B Mt Be ^PI ilk DO • Material, Braided Copper Wire&Stainless Steel Clip&A2.70 boll I I a X 17n x Grounding Ls'w F • High Pre-assembly •Electrlcclly connect Grained Rails Sheet Number C] "rnciing.Junco--- i • Excellent electric conductivity Item No Descriptionr �". DS10 GS C�BJ €�ondiatg te�er `.. 15 16 III Tlr"--,>i.i r- infinitysolc;r CERTIFICATE OF COMPLIANCE iNFINITY HOME SOLUTIONS 8405E MILL PLAIN VANCOUVER WA 98681 PHONE:1.800-818-0598 Certificate Niunher 20 1 8 1 008- E,49 26 3 INFINITY SOLAR.COM Report Reference E499263-201 B0927 REVISIONS Issue Date 2018-OCTOBER-08 o�P�n Data Ray Issued to: XIAMEN GRACE SOLAR TECHNOLOGY CO LTD Bldg, E No. 195 GaoQi BeiSan Road Signature with Seal (GaoOt Industrial Park) Xiamen Fujian 361006 CHINA. This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, Project Name& Address representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE U WITH PHOTOVOLTAIC MODULES AND PANELS Mounting Systems for Use with Photovoltaic Modules and Panels, Model GS-PR-10R. t Have been investigated by UL in accordance with the N to Standard(s)indicated on this Certificate. > N z � " , 0 0 o z � a a Standard(sl for Safety: UL2703"Standard for Mounting Systems, Mounting Luct a ,;; Devices, Clamping/Retention Devices, and Ground Lugs for z Ltd o use with Flat-Plate Photovoltaic Modules and Panels", z `� Additional Information: See the UL Online Certifications Directory at www.uLeomidatabase for additional information } Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Sheet Name Look for the UL Certification Mark on the product. RACKING CERTIFICATION Sheet Size ANSI B 11" X17" Sheet Number DS 11 bfuu MWVNMS G"ac�MVM NYTan Ceettlkatiot Pngmf Vt.ill. 4fh n1Ya,.tn a+tidsm .nvarrns llL Nets Shan IVaddak w S*.fl.,r It,IL(LII aed wIk#vfW t:m>w rc3_.e .,yysb' . .. ^•• :fit a'..ai I.Ce . .vr San".eawm.l i tMpAt.aISNcva991oca1}ane' Page 1 a#1 Created by UL Document Assembler 2018-10-24 22:15:06-05:00